Loading...
PMT16-01958 City of Menifee Permit No.: PMT16-01958 29714 HAUN RD. Type: Residential Electrical �GCEL/ MENIFEE,CA 92586 C'"^kgmt " MENIFEE Date Issued: 07/22/2016 PERMIT Site Address: 30218 MUIRLANDS DR, MENIFEE, CA Parcel Number: 364-370-023 92584 Construction Cost: $6,943.00 Existing Use: Proposed Use: Description of SOLAR TR 30422-3 CAMELLIA Work: 10 MODULES 2.65KW LOT 112 Owner Contractor LENNAR HOMES OF CA LENNAR HOMES OF CALIFORNIA INC 980 MONTECITO DR#302 25 ENTERPRISE CORONA,CA 92879 ALISO VIEJO, CA 92656 Applicant Phone:9493498269 JEREMIAH ACAYTURRI License Number.728102 LENNAR HOMES OF CALIFORNIA INC 25 ENTERPRISE ALISO VIEJO,CA 92656 Fee Description Q1 Amount fEl Solar,Residential or Small Commercial 1 252.00 Building Permit Issuance 1 27.00 GREEN FEE 1 1.00 SMIP RESIDENTIAL 1 1.00 General Plan Maintenance Fee-Electrical 1 12.60 $293.60 The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and specifications or from preventing builiding operations being carried on thereunder when in violation of the Building Code or of any other ordinance of City of Menifee.Except as otherwise stated,a permit for construction under which no work Is commenced within six months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be forfeited. AA_aldg_Pennil_Template.rpt Page 1 of 1 BUILDING & SAFETY PERMIT/PLAN CHECK A. . • ".,""Men M I^ DATE 0 611 5/2 0 1 6 PERMIT/PLAN CHECK NUMBER TYPE: ❑COMMERCIAL ❑✓ RESIDENTIAL ❑MULTI-FAMILY [—]MOBILE HOME ❑POOL/SPA ❑SIGN SUBTYPE: ❑✓ ADDITION ❑ALTERATION []DEMOLITION ❑ELECTRICAL [—]MECHANICAL ❑NEW [:]PLUMBING ❑RE-ROOF-NUMBER OF SQUARES \ DESCRIPTION OF WORK Solar Permit-Plan 2077-2.65 kW/10 PCS Master Solar Permit: PMT14-02630 PROJECT ADDRESS 30218 Muirlands Dr., Menifee, CA 92584 ASSESSOR'S PARCEL NUMBER 364-370-023 LOT 112 TRACT 30422-3 PROPERTY OWNER'S NAME Lennar Homes Df California, Inc. ADDRESS 980 Montecito Dr.,Suite 302, Corona, CA 92879 PHONE (951)817-3680 EMAIL )eremiah.acayturri@lennar.com APPLICANT NAME Lennar Homes of California, Inc. ADDRESS 980 Montecito Dr., Suite 302, Corona, CA 92879 PHONE (951)817-3680 EMAIL jeremiah.acayturri@lennar.com CONTRACTOR'S NAME Lennar Homes of California, Inc. OWNER BUILDER? ❑✓ YES❑NO BUSINESS NAME Lennar Homes of California, Inc. ADDRESS 980 Montecito Dr.,Suite 302, Corona,CA 92879 PHONE (951)817-3680 EMAIL leremiah.acayturri@lennar.com CONTRACTOR'S STATE LIC NUMBER 728102 LICENSE CLASSIFICATION A&B VALUATION$ $6,943.00 SQ FT L SQ FT APPLICANT'S SIGNATURE DATE 06/15/2016 DEPARTMENT DISTRIBUTION CITY OF MENIFEE BUSINESS LICENSE NUMBER BUILDING PLANNING ENGINEERING FIRE GREEN 1110 SMIP INVOICE / PAID AMOUNT AMOUNT J• OCASH OCHECKit 0CREDIT CARD VISA/MC PLAN CHECK FEES PAIDAMOUNT 0CASH 0CHECK# OCREDITCARD VISA/MC OWNER BUILDER VERIFIED OYES O NO DLNUMBER NOTARIZED LETTER O YES O NO City of Menifee Building&Safety Department 29714 Houn Rd. Menifee, CA 92586 951-672-6777 www.cityafinenifee.us Inspection Request Line 951-246-6213 SYSTEM INFORMATION BUYER ACKNOWLEDGES THAT THE SOLAR MODULES TO BE INSTALLED ITEM OTY MFR. MODEL ON THE ROOF OF THE HOME WILL BE SUBSTANTIALLY IN THE SYSTEM SIZE 2.65 KW LOCATIONS INDICATED BY THE ILLUSTRATION. NODULE IO PCS. HYUNDAI HIS-S265RG(265W) BUYER: INVERTER IO PCS. ENPHASE M215-6D-2LL-S22-IG ROOF TYPE I TILE W/COMPOSITE SHINGLE UNDER ARRAY DATE: SUB-ARRAY INFORMATION ARRAY#1 ARRAY#2 ARRAY#3 MOD QTY 10 NA NA BIKER: CITY OF EN TILT 23' NA' NA' IV AZIMUTH 1 90° NA° NA' DATE: City of Menifee DING AN Building Dept k o N AP RO'I JUN2 Sr VPOpentions 3 'Z r LION 1001133 Class B REVI-W Receive 16'-5'ARRAY 1T-3'FLASHING 16'-IW 'Approval of the a plant approval of,any i iolatiol ——————— regulations and C dinan( jobsite until coml letion. t SOILADECK a TRANSITION WIRE TRRANSITION BOX (TINDER ARRAY) I PV AC DISCONNECT EXTERIOR-GARAGE UTILITY METER 6 MAIN SERVILE PANEL — (VERIFIED BY BUILDER) I � I I I I v L---- ---� L O .9 NOTE:DIMENSIONS ARE SHOWN IN PLANE OF ROOF PLAN 2077 ELEVATION C Z IENTATION 2 L #112 CAMELLIA AT LENNAR: ORIGINAL BY: GREG WONG I DATE:I6.04.I2 980 MONTECITO DRIVE.#302 REVIEWED BY:SHAUN MARUNA I DATE:16.04.12 THE LAKES CORONA.CA 92879 REV.# BY DATE DESCRIPTION namasC6 DWG TITLE: PAGE#< SCALE: Simm SITE LOCATION: 4671lcer,G 8 304 INDIVIDUAL MENI MUIRLANDS DRIVE BO3M.4CO80004 PLOT PLAN I/16'=1'-0' MENIFEE.CA 303.447.0300 SYSTEM LAYOUT MODULE SPECS AND CALCULATIONS INVERTER SPECS AND CALCULATIONS ITEM NOTE/CALC UNIT DETAIL ITEM NOTE/CALC UNIT DETAIL LOCATION MENIFEE,CA INV.MAKE INVERTER SPEC ENPHASE TEMP.AMBIENT HIGH(TMAX) ASHRAE 2% °C 37 INV.MODEL INVERTER SPEC M215-60-2LL-S22-IG TEMP.AMBIENT LOW(TMIN) ASHRAE EXTR.MIN •C -2 INV.MAX POWER,(WAC MAX) INVERTER SPEC WATTS(AC) 225 TEMP,MODULE TEST(TTEST) MODULE SPEC °C 25 INV. INPUT V.(VOC MAX) INVERTER SPEC VOLTS 00 48 TEMP.DELTA LOW(TDELTA) TMIN-TTEST •C -27 INV.OUTPUT V.(VAC NOM) INVERTER SPEC VOLTS(AC) 240 MOD.MANUFACTURER MODULE SPEC HYUNDAI INV.OUTPUT FREQUENCY INVERTER SPEC HERTZ 60 MOD.PART NUMBER MODULE SPEC HIS-S265RG INV.OUTPUT CURRENT, Inc INVERTER SPEC AMPS(AC) 0.9 MOD.POWER STC(P) MODULE SPEC WATTS(oc) 265 INV.PHASE QUANTITY INVERTER SPEC PHASE I MOD.POWER PTC MODULE SPEC WATTS(DC) 238 COMPLIANCE INVERTER SPEC UL1741/IEEBIS 7 MOD.OPERATING VOLTAGE �I (VMP) MODULE SPEC VOLTS 00 31.30 INV.GROUNDING INVERTER SPEC ISOLATED MDD.OPEN CCT.VOLTAGE(VOC) MODULE SPEC VOLTS(oc) 38.10 INV.QTY,MAX/BRANCH CCT. INV.QTYBc OTY 10 MOD.COEFF.VOLT/TEMP(COEF) MODULE SPEC V/•C -0.114 BRANCH CCT.OUTPUT,IMAXBC UAc•INV-QTYec) AMPS(AC) 9.00 MOD.MAX VOLTAGE(VMAXMOD) (VOC+(TO-COEF)) VOLTS 00 41.18 INV.QUANTITY,TOTAL INV.QTYT QTY ID MOD. OPERATING CURRENT(IMP) MODULE SPEC AMPS(00 8.50 TOTAL SYSTEM OUTPUT.]MARTS I OAC•INV.QTYT) I AMPS(AC) 9.00 MOD.SHORT CCT. CURRENT(ISO) MODULE SPEC AMPS(00 9.00 MOD. MAXIMUM CURRENT()MAX) USC• 1.25) AMPS 00 11.25 MIN.AMPACITY REQ'D,PER NEC (IMAX'1.25) AMPS 00 14.06 SERIES FUSE RATING.MAX MODULE SPEC AMPS 00 15 - ELECTRICAL EQUIPMENT SCHEDULE � 6 KEY QTY MANUFACTURER MODEL NOTES TRADE I 10 HYUNDAI HIS-S265RG(265W) PV MODULE SOLAR 2 10 ENPHASE 11215-50-21L-522-IG PV INVERTER SOLAR "(3)h' mtruf 3 1 RSTC/SOLADECK 0786-3R5 PV ROOF JUNCTION BOX.NEMA 311 SOLAR 'Y,p OVi ions Of 4 1 CUTLER-HAMMER DG221URB PV AC DISCONNECT,NEMA 3R,24OV,30A SOLAR 5 1 ENPHASE ENVOY PV DATA MONITOR, 120V SOLAR IIiE 52'.0 approi 6 1 TBD TBD 120V DEDICATED RECEPTACLE FOR ENVOY PV DATA MONITOR SOLAR 7 1 TBD TBD CATS PORT FOR SOLAR PV INTERNET CONNECTION TO HOME NETWORK BOX SOLAR 8 NOTE CUTLER-HAMMER TBD PV BRANCH CIRCUIT BREAKERS:I x 15A-IP(ENVOY) SOLAR 9 NOTE CUTLER-HAMMER TBD PV BREAKER.I x 20A-2P,LOCATE AT OPPOSITE END OF BUS FROM MAIN BREAKER SOLAR 10 I TBD TBD SERVICE PANEL,MIN. 125A BUS BLDR. ELEC. II I TBD TBD UTILITY METER, IPH, 120/240V.200A BLDR. ELEC. 12 I TBD TBD GROUNDING ELECTRODE UFER BLDR. ELEC. CONDUCTOR SIZING CALCULATIONS INTERCONNECTION CALCULATIONS O CONDITION OF USE(COU): I (AMPACITY- TEMP. BERATE•FILL BERATE)VS.REQ'D(IMAX) ITEM I UNIT I PANEL 2)TERMINALS(TERM): AMPACITY AT TERMINALS.VS.REQ'4(IMAX• 1.25) PANEL MFR. CUTLER-HAMMER KEY SIZE CU/AL INSULATION CALL. AMPACITY W/0 TEMP. FILL RESULT REQ'D OCD BUS RATING AMPS 200 TYPE BERATES DERATE BERATE (A) (A) 5USED(A). MAIN DISCONNECT AMPS 200 A #12 CU THWN-2 COU 30 0.76 1.0 22.80 9.00ALLOWED PV PER NEC AMPS 40 TERM 25 25 11.25 PV OCPD DEVICE USED AMPS 20 *10NM-BCOU 40 0.91 L0 36.409.00 ///��TTERM 35 35 I1.25 •. \�C #10 CU NM-8 COU 40 GM 1.0 36.40 9.00Mike DUfaulY TERM 35 35 11.25 CONDUCTOR SCHEDULE Sr VP Operations KEY CONDUCTORS CU/AL TYPE LOCATION TRADE Lick 1D01133 Gass B A -#12 ENGAGE CABLE.I-#6G,FREE AIR I CU I TC-ER ARRAY I SOLAR I-#10 EGC I CU I NM-B(ROMEX) I INTERIOR I SOLAR C 34ID, I-#ID EGC I CU I NM-B(ROMEX) I INTERIOR SOLAR D I CAT5E.ETHERNET CABLE I Cu I CAT5E I INTERIOR SOLAR 5 6 11 7 � o 0 � M — SEE NOTE 15 10 O 0rT 9 $(I O A/1P _ Al D G j A ROOF EXTERIOR-GARAGE ELECTRICAL DIAGRAM 2.65 KW LOT#112 ORIGINAL BY: GREG WONG DATE:16.04.12 CAMELLIA AT LENNAR: REVIEWED BY:SHAUN MARUNA DATE:16.04.12 980 NA.CAI 2 DRIVE.#3D2 Vnannast;6 THE LAKES CORONA.CA 9879 REV.# BY DATE DESCRIPTION DINGSOLAR TITLE: PAGE#: SCALE: SITE LOCATION: INDIVIDUAL 30218 MUIRLANDS DRIVE 4 lder,DO8Bmdway Street Bo PLOT PLAN 2 NTS MENIFEE.CA 303.447.0300� ELECTRICAL STRUCTURAL NOTES: SOLAR CONTRACTOR- Mike DOfaUlt U ALL PV ROOF ATTACHMENTS WILL BE SPACED ALONG MODULE RACKING RAILS AT NOT GREATER THAN 48'O.C. Sr VP Operations 2)ALL PV ROOF ATTACHMENTS WILL BE STAGGERED BY ROW AMONGST THE ROOF FRAMING MEMBERS,TO MAXIMUM EXTENT POSSIBLE. LIC#1001133 Gass B 3)ROOF PENETRATIONS ASSOCIATED WITH SOLAR RACKING WILL BE SEALED WITH AN APPROVED SEALANT. 4)SOLADECK WIRE TRANSITION BOX WILL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS, IT WILL BE FLASHED AND SEALED. 5)PV ARRAY WILL BE A MINIMUM OF 3-ABOVE THE COMPOSITE SHINGLE ROOF SURFACE. 6)THE UNIRAC SOLARMOUNT RACKING SYSTEM AND SOLAR PV ARRAY WILL BE INSTALLED ACCORDING TO THE UNIRAC SOLARMOUNT CODE-COMPLIANT INSTALLATION MANUAL,VERSION 227.3.PUB 140113-ICC,JANUARY 2014. 7)UNIRAC TOP CLAMPS REQUIRE A ONE INCH 0')SPACE BETWEEN PV MODULES.SOLARMOUNT RAILS MUST EXTEND A MINIMUM OF TWO INCHES(T)BEYOND THE EDGE OF THE PV ARRAY/SUB-ARRAY. 8)UNIRAC SOLARMOUNT REQUIRES THAT A THERMAL EXPANSION GAP BE INSTALLED FOR ANY RAIL LENGTH OF GREATER THAN 60'. A. THE ROOFING CONTRACTOR- D DISTANCE BETWEEN ARRAY EDGE AND TRANSITION FLASHING(COMPOSITION TO TILE)WILL BE A MINIMUM OF 3'. 2)26 GAUGE INTERLOCKING FLASHING'SIDEWALL'TO BE INSTALLED ALONG THE LENGTH OF THE PV ARRAY AT ROOFING MATERIAL TRANSITION. IT SHALL BE APROVED PRIOR TO PV SYSTEM INSTALLATION. 3)PEEL-N-STICK BASE TO BE INSTALLED ONE FOOT 01 OR MORE BEYOND THE EDGE OF THE COMPOSITION SHINGLE,DOWN TO THE ROOF EAVE.PEEL-N-STICK BASE TO BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS. 4)AREAS UNDER EACH PV ARRAY SHALL BE ROOFED WITH COMPOSITION SHINGLE. COMPOSITION SHINGLE SMALL RUN FROM ABOVE THE PV ARRAY TO THE ROOF EAVE. 5)TILE INSTALLED BELOW THE ARRAY TO BE INSTALLED ABOVE THE COMPOSITION ROOF PER ROOFER SPECIFICATIONS. 6)BIRDSTOP WILL BE INSTALLED AT THE UPPERMOST TRANSITION FROM TILE TO COMPOSITION SHINGLE. BIRDSTOP TO BE SPECIFIED BY ROOFER PRIOR TO INSTALLATION. le permit ed ral,state ):an must be ELECTRICAL NOTES: GENERAL- U ALL PV EQUIPMENT WILL BE TESTED AND LISTED FOR ITS USE BY A NATIONALLY RECOGNIZED TESTING LABORATORY(NRTL). 2)THE GROUNDING OF THE PHOTOVOLTAIC SYSTEM SMALL COMPLY WITH THE APPLICABLE VERSION OF THE NEC/CEC. 3)ALL GROUNDING ELECTRODE CONDUCTORS WILL BE INSTALLED IN A CONTINUOUS LENGTH EXCEPT WHERE SPLICED BY AN IRREVERSIBLE CONNECTOR OR EXOTHERMIC WELD. 4)NON-CURRENT CARRYING METAL PARTS SHALL BE CHECKED FOR PROPER GROUNDING,NOTING THAT TERMINAL LUGS BOLTED ON AN ENCLOSURE'S FINISHED SURFACE MAY BE ELECTRICALLY INSULATED BECAUSE OF PAINT/FINISH. PAINT/FINISH AT POINT OF CONTACT SHALL BE PROPERLY REMOVED. 5)ROOF PENETRATIONS WILL BE COMPLETED AND SEALED PER APPLICABLE CODE.. 6)ALL CONDUCTORS WILL HAVE A 90-C RATING TO ENSURE CODE COMPLIANCE. SOLAR CONTRACTOR- 7)MODULE CERTIFICATIONS WILL INCLUDE UL1703, IEC61646.IEC61730. 8)CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS. 9)RACEWAY POINT OF PENETRATION FROM EXTERIOR TO INTERIOR WILL BE SEALED TO PREVENT INGRESS OF WATER AND INSECTS. 10)DC WIRING IS LIMITED TO PV ARRAY FOOTPRINT W/ENPHASE MICRO-INVERTER SYSTEM. ID MODULE AND ENPHASE WIRING SHALL BE LOCATED AND SECURED UNDER THE ARRAY USING SUITABLE WIRING CLIPS. WIRING SHALL NOT MAKE CONTACT WITH THE ROOF SURFACE AND SHALL BE MANAGED IN A WORKMAN-LIKE MANNER. 12)EQUIPMENT GROUNDING CONDUCTORS WILL BE SIZED IN ACCORDANCE WITH NEC TABLE 250.122. 13)CONDUCTOR TERMINATIONS WILL BE TORQUED PER DEVICE LISTING,OR MANUFACTURER'S RECOMMENDATIONS. 14)A PV AGGREGATION PANEL(SUB PANEL)WILL NOT BE INCLUDED FOR SYSTEMS WITH ONE BRANCH CIRCUIT. 15)A DEDICATED 120V BRANCH CIRCUIT IS REQUIRED IN MASTER CLOSET(OR EDUIVALENT)FOR ENPHASE ENVOY MONITOR. SIGNAGE- 16)PV SYSTEMS SHALL BE CLEARLY MARKED IN ACCORDANCE WITH NEC ARTICLE 690 AND OTHER APPLICABLE STATE AND LOCAL CODES. 17)ALL SAFETY MARKING/PLACARDS SHALL BE PERMANENTLY ATTACHED BY ADHESIVE OR OTHER MECHANICAL MEANS. 18)MARKING/PLACARDS WILL BE METAL OR PLASTIC WITH ENGRAVED OR MACHINE PRINTED LETTERING.BACKGROUND WILL BE RED WITH WHITE CAPITAL LETTERING OF MINIMUM HEIGHT?. 19)ALL WIRING/RACEWAYS/JUNCTION BOXES WILL BE 14ARKED'PHOTOVOLTAIC POWER SOURCE:OR EQUIVALENT:WIRING/RACEWAYS SHALL BE MARKED EVERY 10'. BUILDER ELECTRICAL AND SOLAR CONTRACTORS- 20)INSTALLATION SHALL BE COMPLETED IN A NEAT AND WORKMAN-LIKE MANNER- 20 SPACE REQUIREMENTS FOR ALL ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110.26. ORIGINAL BY: GREG WONG DATE:I . LENNAR: 04.12 CAMELLIA AT REVIEWED BY:SHAUN MARUNA I DATE:16.04.12 980 MONTECITO DRIVE,#302 THE LAKES CORONA,CA 92879 REV.# BY DATE DESCRIPTION %mcist;6 SOLAR DWG TITLE: PAGE#: I SCALE: SITE LOCATION: treet INDIVIDUAL 4577 Broadway 304 PLOT PLAN 3 NTS MENI MUIRLANDS DRIVE Boulder,303. 0080304 MENIFEE,CA 303.44].0300 NOTES Mike Dufault Sr VP Operations Llc#1001133 Class B CAUTION: POWER TO THIS BUILDING IS SUPPLIED BY THE UTILITY AND A SOLAR PV SYSTEM. DISCONNECTS ARE LOCATED AS SHOWN. r WE )ran Ay on e SOLADECK WIRE TRANSITION BOX (UNDER ARRAY) PV AC DISCONNECT EXTERIOR-GARAGE UTILITY METER B MAIN SERVICE PANEL (VERIFIED BY BUILDER) SERVICE BY QUALIFIED PERSONNEL ONLY CONTACT: SUNSTREET ENERGY GROUP 1-677-SLR-POWR PV POWER SOURCE — AC SPECS AC OPERATING VOLTAGE: 240 V AC OPERATING CURRENT: 9.0 A NOTE: SEE MASTER SET FOR ADDITIONAL PLACARD INFORMATION ORIGINAL BY: GREG WONG I DATE:16.OL. 980 MONTECITD DRIVE,#302 12 CAMELLIA AT LENNAR: REVIEWED BY:SHAUN MARUNA DATE:16.04.12 THE LAKES CORONA,CA 92B79 REV.# BY DATE DESCRIPTION namast6 SOLAR DWG TITLE: PAGE#: SCALE: SITE LOCATION: 4571 Broadw ay Street INDIVIDUAL MENI EE.CA N05 DRIVE Boulder, 7030300 PLOT PLAN 4 NTS MENIFEE,LA 303.447.0300 PLACARDS