PMT16-01957 City of Menifee Permit No.: PMT16-01957
29714 HAUN RD. Type: Residential Electrical
-t'ACCEL/? MENIFEE,CA 92586
aSA— MENIFEE Date Issued: 07122/2016
PERMIT
Site Address: 30206 MUIRLANDS DR,MENIFEE, CA Parcel Number: 364-370-022
92584 Construction Cost: $7,650.40
Existing Use: Proposed Use:
Description of SOLAR TR 30422-3 CAMELLIA
Work: 11 MODULES 2.92KW
LOT 111
Owner Contractor
LENNAR HOMES OF CA LENNAR HOMES OF CALIFORNIA INC
980 MONTECITO DR#302 25 ENTERPRISE
CORONA, CA 92879 ALISO VIEJO,CA 92656
Applicant Phone:9493498269
JEREMIAH ACAYTURRI License Number.728102
LENNAR HOMES OF CALIFORNIA INC
25 ENTERPRISE
ALISO VIEJO, CA 92656
Fee Description Oft Amount!$1
Solar,Residential or Small Commercial 1 252.00
Building Permit Issuance 1 27.00
GREEN FEE 1 1.00
SMIP RESIDENTIAL 1 1.00
General Plan Maintenance Fee-Electrical 1 12.60
$293.60
The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and
specifications or from preventing building operations being carried on thereunder when in violation of the Building Code or of any other
ordinance of City of Menifee.Except as otherwise stated,a permit for construction under which no work is commenced within six
months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be
forfeited.
AA_Bldg_Permil_Template.rpt Page 1 of 1
• APPLICATION
4t:
t
'Menifee
DATE 06/15/2016 PERMIT/PLAN CHECK NUMBER plr I�IV �5�
TYPE: ❑COMMERCIAL ❑✓ RESIDENTIAL ❑MULTI-FAMILY ❑MOBILE HOME ❑POOL/SPA ❑SIGN
SUBTYPE: ✓❑ADDITION ❑ALTERATION [—]DEMOLITION [—]ELECTRICAL [-]MECHANICAL
❑NEW ❑PLUMBING ❑RE-ROOF-NUMBER OF SQUARES
DESCRIPTION OF WORK Solar Permit-Plan 2399-2.92 kW/11 PCS
Master Solar Permit: PMT14-02630
PROJECTADDRESS 3020B Mulrlands Dr., Menifee, CA 92584
ASSESSOR'S PARCEL NUMBER 364-370-022 LOT 111 TRACT 30422-3
PROPERTY OWNER'S NAME Lennar Homes of California, Inc.
ADDRESS 980 Montecito Dr.,Suite 302,Corona, CA 92879
PHONE (951)817-3680 EMAIL jeremiah.acayturri@lennar.com
APPLICANT NAME Lennar Homes of California, Inc.
ADDRESS 960 Montecito Dr., Suite 302, Corona,CA 92879
PHONE (951)817-3680 EMAIL jeremiah.acayturri@lennar.com
CONTRACTOR'S NAME Lennar Homes of California, Inc. OWNER BUILDER? ❑✓ YES❑NO
BUSINESS NAME Lennar Homes of California, Inc.
ADDRESS 980 Montecito Dr.,Suite 302, Corona,CA 92879
PHONE (951)817-3680 EMAIL jeremiah.acayturri@lennar.com
CONTRACTOR'S STATE LIC NUMBER 728102 LICENSE CLASSIFICATION A&B
VALUATION$ $7,650.40 L SQ FT
APPLICANT'S SIGNATURE DATE 06/15/2016
CITYSTAFF USE ONLY
DEPARTMENT DISTRIBUTION CITY OF MENIFEE BUSINESS LICENSE NUMBER
BUILDING PLANNING ENGINEERING FIRE GREEN I SMIP
INVOICE ^l PAID AMOUNT
AMOUNT .!� •� 0 CASH ()CHECK# OCREDITCARD VISA/MC
PLAN CHECK FEES PAIDAMOUNT OCASH OCHECK# ()CREDIT CARD VISA/MC
OWNER BUILDER VERIFIED O YES O. NO DL NUMBER NOTARIZED LETTER O YES O NO
City of Menifee Building&Safety Department 29714 Houn Rd. Menifee, CA 92586 951-672-6777
www.cityofinenifee.us Inspection Request Line 951-246-6213
SYSTEM INFORMATION BUYER ACKNOWLEDGES THAT THE SOLAR MODULES TO BE INSTALLED
ITEM OTY MFR. MODEL ON THE ROOF OF THE HOME WILL BE SUBSTANTIALLY IN THE
SYSTEM SIZE 1 2.92 KW 1 LOCATIONS INDICATED BY THE ILLUSTRATION.
MODULE 1 II PCS.1 HYUNDAI HIS-S265RG(265W) I BUYER:
INVERTER 1 II PCS'j ENPHASE 1 M215-6D-2LL-S22-IG
ROOF TYPE I TILE W/COMPOSITE SHINGLE UNDER ARRAY DATE:
SUB-ARRAY INFORMATION
ARRAY#1 ARRAY#2 1 ARRAY#3 City of Menifee
MOD OTY II NA NA Building Dept BUYER: i ? lJ!-
` F
TILT 23° NA' NA-
___AZIMUTH 90° NA' NA' DATE:
JUN 23 2013 DIN
ik J
Mike Du '
ult , !-F.>1 AP
Sr VPOperationsReceive _
Lid 1001133 Class 8
�I..S 0f they
29'-B'ARRAY 9ba) f,any t
7'-10' 30'-6'FLASHING ';:'ilat101$any D
1 3I(e Dn it camp
_ II
f
TRANSITION BOXSOLADECK WIRE
(UNDER ARRAY)
PV AC DISCONNECT
EXTERIOR-GARAGE
UTILITY METER 8
——————
MAIN SERVICE PANE L
(VERIFIED BY BUILDER
) }
cc.
u
pp
I _
NOTE:DIMENSIONS ARE SHOWN IN PLANE OF ROOF
Z
PLAN 2399 ELEVATION A-REVERSE
ORIENTATION 2 LOT# III
LENNAR: ORIGINAL BY: GREG WONG DATE:16.04.1
CAMELLIA AT 2
980 MONTECITO DRIVE.#302 REVIEWED BY:SHAUN MARUNA DATE:16.04.12
THE LAKES CORONA.CA 92879 REV.# BY DATE I DESCRIPTION
namasb8
IOLAII
DWG TITLE: PAGE#: SCALE: SITE LOCATION:
4571 Broadway Street
Bo
INDIVIDUAL 30206 MUIRLANDS DRIVE Boulder.C08000C
PLOT PLAN 301
I/16'=I'-0' MENIFEE.CA 303.497.0300
SYSTEM LAYOUT
MODULE SPECS AND CALCULATIONS INVERTER SPECS AND CALCULATIONS
ITEM NOTE/CALC UNIT DETAIL ITEM NOTE/CALC I UNIT DETAIL
LOCATION MENIFEE.CA INV.MAKE INVERTER SPEC ENPHASE
TEMP.AMBIENT HIGH(TMAX) ASHRAE 2% 'C 37 INV.MODEL INVERTER SPEC M215-60-2LL-S22-IG
TEMP.AMBIENT LOW(THIN) ASHRAE EXTR.MIN 'C -2 INV.MAX POWER.(WAC MAX) INVERTER SPEC WATTS(AC) 225
TEMP,MODULE TEST(TTEST) MODULE SPEC °C 25 INV. INPUT V.(Voc MAX) INVERTER SPEC VOLTS(DC) 48
TEMP,DELTA LOW(TOELTA) THIN-TTEST °C -27 INV.OUTPUT V.(Vac NOM) INVERTER SPEC VOLTS(AC). 24D
MOD.MANUFACTURER MODULE SPEC HYUNDAI INV.OUTPUT FREQUENCY INVERTER SPEC HERTZ 60
MOD.PART NUMBER MODULE SPEC HIS-SZ65RG INV.OUTPUT CURRENT,IAC INVERTER SPEC AMPS(AC) 0.9
MOD.POWER STC(P) MODULE SPEC WATTS(DC) 265 INV.PHASE QUANTITY INVERTER SPEC PHASE I
MOD.POWER FTC MODULE SPEC WATTS(DC) 238 COMPLIANCE INVERTER SPEC UL1741/IEEEISJµ"/
MOD. OPERATING VOLTAGE(VMP) MODULE SPEC VOLTS(DC) 31.30 INV. GROUNDING INVERTER SPEC ISOLATED
MOD. OPEN CCT.VOLTAGE(VOC) MODULE SPEC VOLTS(DC) 55.10 INV. CITY,MAX/BRANCH CCT. INV.QTYBC OTY 1 II `) AinSAFE
MOD. COEFF.VOLT/TEMP(COEF) MODULE SPEC V/°C -0.114 BRANCH CCT.OUTPUT,IMAXOC (IAC°INV.QTYBC) AMPS(AC) 9.94
MOD. MAX VOLTAGE(VMAXMOD) (VOC a(TD-COEF)) VOLTS(DC) 41.18 INV.QUANTITY,TOTAL I INV.QTYT CITY 1 II
MOD. OPERATING CURRENT(IMP) MODULE SPEC AMPS(DC) 8.50 TOTAL SYSTEM OUTPUT,IMAXTs I(IAC°INV.GTYT) I AMPS(AC) 1 9.90 /
MOD. SHORT CCT.CURRENT(ISC) MODULE SPEC AMPS(DC) 9.00
MOD.MAXIMUM CURRENT(IMAx) (ISC° 1.25) AMPS(OC) 11.25
MIN.AMPACITY REQ'D,PER NEC (1MA.x' 1.25) AMPS(DC) 14.06
SERIES FUSE RATING,MAX MODULE SPEC AMPS(DC) 15
ELECTRICAL EQUIPMENT SCHEDULE -
KEY CITY MANUFACTURER MODEL NOTES TRADE
1 II HYUNDAI HIS-S265RG(265W) PV MODULE SOLAR
2 11 ENPHASE M215-60-2LL-S22-IG PV INVERTER SOLAR
3 1 RSTC/SOLADECK 07863R5 PV ROOF JUNCTION BOX.NEMA 3R SOLAR ''i shall not be
4 1 CUTLER-HAMMER DG221URB PV AC DISCONNECT.NEMA 3R,240V.30A SOLAR
5 1 ENPHASE ENVOY PV DATA MONITOR,120V SOLAR Od of o!Y'Pr0V1s
6 1 TBD TBD 120V DEDICATED RECEPTACLE FOR ENVOY PV DATA MONITOR SOLAR
7 1 TBD TBD CATS PORT FOR SOLAR PV INTERNET CONNECTION TO HOME NETWORK BOX SOLAR .ITi Es. Tt is set of
B NOTE CUTLER-HAMMER TBD PV BRANCH CIRCUIT BREAKERS;I x 15A-IP(ENVOY) SOLAR i)
9 NOTE CUTLER-HAMMER TBD PV BREAKER,I x 2DA-2P,LOCATE AT OPPOSITE END OF BUS FROM MAIN BREAKER SOLAR
10 I TBD TBD SERVICE PANEL.MIN. 125A BUS BLDR.ELEC.
II I TBD TBD UTILITY METER.IPH,1201240V,2DOA BLDR.ELEC.
12 I TBD TBD GROUNDING ELECTRODE UFER BLDR.ELEC.
CONDUCTOR SIZING CALCULATIONS INTERCONNECTION CALCULATIONS
1)CONDITION OF USE(COI): I (AMPACITY° TEMP.DERATE °FILL DERATE)vs.REO'D(IMAx) ITEM I UNIT I PANEL
2)TERMINALS(TERM I AMPACITY AT TERMINALS. Vs.REO'D.(IMAX • 1.25) PANEL MFR. I CUTLER-HAMMER
KEY SIZE CU/AL INSULATION CALC. AMPACITY W/0 TEMP. FILL RESULT REQ'D USE BUS RATING AMPS 200
TYPE DERATES DERATE DERATE (A) (A) USED(A) MAIN DISCONNECT AMPS 200
A #12 CU THWN-2 COU 30 0.76 1.0 22.80 9.90 ALLOWED PV PER NEC AMPS 40
TERM 25 25 12.38 20 PV OCPD DEVICE USED AMPS 20
8 #10 CU NM-8
COU 40 0.91 1.0 66.40 9.90
TERM 35 35 12.38 20 •. � ,`�
C *10 CU NM-B COU 40 0.91 1.0 36.40 9.90 MikE Default
TERM 35 35 12.38 20
CONDUCTOR SCHEDULE Sr VP operations
LicH 1001133 Class B
KEY CONDUCTORS CU/AL TYPE LOCATION TRADE
q 1-#12 ENGAGE CABLE.1-#6G,FREE AIR CU TC-ER ARRAY SOLAR
B 3-#10.1-#10 EGG CU NM-B(ROMEX) INTERIOR SOLAR
C 3-#10.1-#10 EGC CU NM-B(ROMEX) INTERIOR SOLAR
0 CAT5E.ETHERNET CABLE CUP CAT5E INTERIOR SOLAR 5 6 II
OB e o
M -
SEE NOTE 15 I 10
0
(SNIP
O O 9
0 � �
3
I"
1 B
G ! G�
A C
ROOF EXTERIOR-GARAGE
ELECTRICAL DIAGRAM 2.92 xW
LOT#III
ORIGINAL BY: GREG WONG DATE:
LENNAR: 16.OL.12
CAMELLIA AT REVIEWED BY:SHAUN MAR UNA DATE:16.04.12
980 MONTECITO DRIVE.#302
THE LAKES CORONA,CA 921179 REV.# BY DATE DESCRIPTION
namast6
SOLA!
DWG TITLE: PAGE#: SCALE: SITE LOCATION: 4571 Broadway Street
INDIVIDUAL 30206 MUIRLANDS DRIVE Boulder,CO 80304
PLOT PLAN 2 NTS MENIFEE,CA 303.447.0300
ELECTRICAL
STRUCTURAL NOTES: Mike DUFaDit
SOLAR CONTRACTOR- $r VP Operations
I)ALL PV ROOF ATTACHMENTS WILL BE SPACED ALONG MODULE RACKING RAILS AT NOT GREATER THAN LB'O.L.
2)ALL PV ROOF ATTACHMENTS WILL BE STAGGERED BY ROW AMONGST THE ROOF FRAMING MEMBERS,TO MAXIMUM EXTENT POSSIBLE. CIO#1001133 Class B
3)ROOF PENETRATIONS ASSOCIATED WITH SOLAR RACKING WILL BE SEALED WITH AN APPROVED SEALANT.
4)SOIADECK WIRE TRANSITION BOX WILL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS. IT WILL BE FLASHED AND SEALED,
5)PV ARRAY WILL BE A MINIMUM OF 3-ABOVE THE COMPOSITE SHINGLE ROOF SURFACE.
6)THE UNIRAC SOLARMOUNT RACKING SYSTEM AND SOLAR PV ARRAY WILL BE INSTALLED ACCORDING TO THE UNIRAC SOLARMOUNT CODE-COMPLIANT INSTALLATION
MANUAL.VERSION 227.3,PUB 140113-ICC,JANUARY 2014.
7)UNIRAC TOP CLAMPS REQUIRE A ONE INCH 01 SPACE BETWEEN PV MODULES.SOLARMOUNT RAILS MUST EXTEND A MINIMUM OF TWO INCHES Z')BEYOND THE EDGE
OF THE PV ARRAY/SUB-ARRAY.
8)UNIRAC SOLARMOUNT REQUIRES THAT A THERMAL EXPANSION GAP BE INSTALLED FOR ANY RAIL LENGTH OF GREATER THAN 40'. D PQRI
ROOFING CONTRACTOR-
I)DISTANCE BETWEEN ARRAY EDGE AND TRANSITION FLASHING(COMPOSITION TO TILE)WILL BE A MINIMUM OF 3'.
2)26 GAUGE INTERLOCKING FLASHING'SIDEWALL'TO BE INSTALLED ALONG THE LENGTH OF THE PV ARRAY AT ROOFING MATERIAL TRANSITION. IT SHALL BE
APROVED PRIOR TO PV SYSTEM INSTALLATION.
3)PEEL-N-STICK BASE TO BE INSTALLED ONE FDOT(I')OR MORE BEYOND THE EDGE OF THE COMPOSITION SHINGLE.DOWN TO THE ROOF EAVE. PEEL-N-STICK BASE TO
BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS.
4)AREAS UNDER EACH PV ARRAY SHALL BE ROOFED WITH COMPOSITION SHINGLE.COMPOSITION SHINGLE SHALL RUN FROM ABOVE THE PV ARRAY TO THE ROOF EAVE.
5)TILE INSTALLED BELOW THE ARRAY TO BE INSTALLED ABOVE THE COMPOSITION ROOF PER ROOFER SPECIFICATIONS.
6)BIRDSTOP WILL BE INSTALLED AT THE UPPERMOST TRANSITION FROM TILE TO COMPOSITION SHINGLE. BIRDSTOP TO BE SPECIFIED BY ROOFER PRIOR TO
INSTALLATION.
trbeapt
tt a federal,
:ve plansmt
ELECTRICAL NOTES:
GENERAL-
0 ALL PV EQUIPMENT WILL BE TESTED AND LISTED FOR ITS USE BY A NATIONALLY RECOGNIZED TESTING LABORATORY(NRTL).
2)THE GROUNDING OF THE PHOTOVOLTAIC SYSTEM SHALL COMPLY WITH THE APPLICABLE VERSION OF THE NEC/CEC.
3)ALL GROUNDING ELECTRODE CONDUCTORS WILL BE INSTALLED IN A CONTINUOUS LENGTH EXCEPT WHERE SPLICED BY AN IRREVERSIBLE CONNECTOR OR EXOTHERMIC
WELD.
4)NON-CURRENT CARRYING METAL PARTS SHALL BE CHECKED FOR PROPER GROUNDING.NOTING THAT TERMINAL LUGS BOLTED ON AN ENCLOSURE'S FINISHED SURFACE
MAY BE ELECTRICALLY INSULATED BECAUSE OF PAINT/FINISH. PAINT/FINISH AT POINT OF CONTACT SHALL BE PROPERLY REMOVED.
5)ROOF PENETRATIONS WILL BE COMPLETED AND SEALED PER APPLICABLE CODE.
6)ALL CONDUCTORS WILL HAVE A 90"C RATING TO ENSURE CODE COMPLIANCE.
SOLAR CONTRACTOR-
7)MODULE CERTIFICATIONS WILL INCLUDE UL1703, IEC61646.IEC61730.
8)CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS.
9)RACEWAY POINT OF PENETRATION FROM EXTERIOR TO INTERIOR WILL BE SEALED TO PREVENT INGRESS OF WATER AND INSECTS.
10)DC WIRING IS LIMITED TO PV ARRAY FOOTPRINT W/ENPHASE MICRO-INVERTER SYSTEM.
10 MODULE AND ENPHASE WIRING SHALL BE LOCATED AND SECURED UNDER THE ARRAY USING SUITABLE WIRING CLIPS.WIRING SHALL NOT MAKE CONTACT WITH THE
ROOF SURFACE AND SHALL BE MANAGED IN A WORKMAN-LIKE MANNER.
12)EQUIPMENT GROUNDING CONDUCTORS WILL BE SIZED IN ACCORDANCE WITH NEC TABLE 250.122.
13)CONDUCTOR TERMINATIONS WILL BE TORQUED PER DEVICE LISTING,OR MANUFACTURER'S RECOMMENDATIONS.
14)A PV AGGREGATION PANEL(SUB PANEL)WILL NOT BE INCLUDED FOR SYSTEMS WITH ONE BRANCH CIRCUIT.
15)A DEDICATED 120V BRANCH CIRCUIT IS REQUIRED IN MASTER CLOSET(OR EQUIVALENT)FOR ENPHASE ENVOY MONITOR.
SIGMAGE-
16)PV SYSTEMS SHALL BE CLEARLY MARKED IN ACCORDANCE WITH NEC ARTICLE 690 AND OTHER APPLICABLE STATE AND LOCAL CODES.
17)ALL SAFETY MARKING/PLACARDS SHALL BE PERMANENTLY ATTACHED BY ADHESIVE OR OTHER MECHANICAL MEANS.
18)MARKING/PLACARDS WILL BE METAL OR PLASTIC WITH ENGRAVED OR MACHINE PRINTED LETTERING.BACKGROUND WILL BE RED WITH WHITE CAPITAL LETTERING OF
MINIMUM HEIGHT J'.
19)ALL WIRING/RACEWAYS/JUNCTION BOXES WILL BE MARKED'PHOTOVOLTAIC POWER SOURCE;OR EQUIVALENT;WIRING/RACEWAYS SHALL BE MARKED EVERY 10'.
BUILDER ELECTRICAL AND SOLAR CONTRACTORS-
20)INSTALLATION SHALL BE COMPLETED IN A NEAT AND WORKMAN-LIKE MANNER.
21)SPACE REQUIREMENTS FOR ALL ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110.26.
CAMELLIA AT ORIGINAL BY: GREGWONG DATE:16.04.12
LENNAR: REVIEWED BY:SHAUN MAR NA DATE:16,04.12
980 MONTECITO DRIVE,#302 REV.# BY DATE DESCRIPTION •�
CORONA,CA 92879
THE LAKES namas.6
SO LA.
DWG TITLE: PAGE#: SCALE: SITE LOCATION: 4571 Broadway Street
INDIVIDUAL 3 NTS 30206 MUIRLANDS DRIVE Boulder.CO B0304
PLOT PLAN MENIFEE.CA 303,447.0300
NOTES
Mike Oufault
Sr VP Operations
Licit 1001133 Class B
CAUTION:
POWER TO THIS BUILDING IS SUPPLIED BY THE
UTILITY AND A SOLAR PV SYSTEM. DISCONNECTS
ARE LOCATED AS SHOWN.
DA E
for,or an
or city
kept on th
SOLADECX WIRE
TRANSITION BOX
(UNDER ARRAY)
PV AC DISCONNECT
EXTERIOR-GARAGE
UTILITY METER 6
MAIN SERVICE PANEL
(VERIFIED BY BUILDER)
SERVICE BY QUALIFIED PERSONNEL ONLY
CONTACT: SUNSTREET ENERGY GROUP
1-877-SLR-POWR
PV POWER SOURCE - AC SPECS
AC OPERATING VOLTAGE: 240 V
AC OPERATING CURRENT: 9.9 A
NOTE: SEE MASTER SET FOR ADDITIONAL PLACARD INFORMATION
ORIGINAL BY: GREG WONG DATE:16.0&.12
CAMELLIA AT LENNAR: REVIEWED BY:SHAUN MARUNA DATE:16.04.12
980 MONTECITO DRIVE,#302 )
THE LAKES CORONA.CA 92879 REV.# BY DATE DESCRIPTION
0 namasre
vouv
DWG TITLE: PAGE #: SCALE: SITE LOCATION: 4671 Broadway Street
INDIVIDUAL 30206 MUIRLANDS DRIVE Boulder,CO 80304
PLOT PLAN L NTB MENIFEE,CA 30344].0300
PLACARDS