Loading...
PMT16-01954 City of Menifee Permit No.: PMT16-01954 29714 HAUN RD. -c-►CCELA— MENIFEE,CA 92586 Type: Residential Electrical MENIFEE Date Issued: 0 7/2 212 01 6 PERMIT Site Address: 29621 ARGYLE CIR, MENIFEE, CA 92584 Parcel Number: 364-360-037 Construction Cost: $8,331.60 Existing Use: Proposed Use: Description of SOLAR TR 30422-3 CAMELLIA Work: 12 MODULES 3.18KW LOT 128 Owner Contractor LENNAR HOMES OF CA LENNAR HOMES OF CALIFORNIA INC 980 MONTECITO DR#302 25 ENTERPRISE CORONA, CA 92879 ALISO VIEJO,CA 92656 Applicant Phone:9493498269 JEREMIAH ACAYTURRI License Number:728102 LENNAR HOMES OF CALIFORNIA INC 25 ENTERPRISE ALISO VIEJO,CA 92656 Fee Description 01t r Amount($1 Solar, Residential or Small Commercial 1 252.00 Building Permit Issuance 1 27.00 GREEN FEE 1 1.00 SMIP RESIDENTIAL 1 2.00 General Plan Maintenance Fee-Electrical 1 12.60 $294.60 The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and specifications or from preventing bulliding operations being carded on thereunder when in violation of the Building Code or of any other ordinance of City of Menifee.Except as otherwise stated,a permit for construction under which no work is commenced within six months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be forfeited. AA_Bidg_Permit_Template.rpt Page 1 of 1 BUILDING & SAFETY PERMIT/PLAN CHECK A. . • �"'Menifee DATE 06/15/2016 PERMIT/PLAN CHECK NUMBER TYPE: ❑COMMERCIAL ❑✓ RESIDENTIAL ❑MULTI-FAMILY ❑MOBILE HOME ❑POOL/SPA []SIGN SUBTYPE: ❑✓ ADDITION [—]ALTERATION ❑DEMOLITION [—]ELECTRICAL ❑MECHANICAL ❑NEW []PLUMBING ❑RE-ROOF-NUMBER OF SQUARES DESCRIPTION OF WORK Solar Permit-Plan 2785-3.18 kW/12 PCS Master Solar Permit: PMT14-02630 PROJECTADDRESS 29621 Argyle Circle., Menifee, CA 92584 ASSESSOR'S PARCEL NUMBER 36y- 360—n3 /-7 LOT 128 TRACT 30422-3 PROPERTY OWNER'S NAME Lennar Homes of California, Inc. ADDRESS 980 Montecito Dr., Suite 302,Corona,CA 92879 PHONE (951)817-3680 EMAIL jeremiah.acaytuni@lennar.com APPLICANT NAME Lennar Homes of California, Inc. ADDRESS 980 Montecito Dr., Suite 302, Corona,CA 92879 PHONE (951)817-3680 EMAIL jeremiah.acayturri@lennar.com CONTRACTOR'S NAME Lennar Homes of California, Inc. OWNER BUILDER? ❑✓ YES❑NO BUSINESS NAME Lennar Homes of California, Inc. ADDRESS 980 Montecito Dr.,Suite 302, Corona, CA 92879 PHONE (951)817-3680 EMAIL leremiah.acayturri@lennar.com CONTRACTOR'S STATE LIC NUMBER 728102 LICENSE CLASSIFICATION A&B VALUATION$ $8,331.60 T L SQ FT APPLICANT'S SIGNATURE DATE 06I15/2016 DEPARTMENT DISTRIBUTION `/ CITY OF MENIFEE BUSINESS LICENSE NUMBER BUILDING PLANNING ENGINEERING FIRE GREEN SMIP INVOICE PAID AMOUNT AMOUNT OCASH OCHECK# 0CREDIT CARD VISA/MC PLAN CHECK FEES PAID AMOUNT O CASH O CHECK# O CREDIT CARD VISA/MC OWNER BUILDER VERIFIED O YES O NO DL NUMBER NOTARIZED LETTER O YES-O NO City of Menifee Building&Safety Department 29714 Houn Rd. Menifee, CA 92586 951-672-6777 www.cityofTIenifee.us Inspection Request Line 951-246-6213 SYSTEM INFORMATION BUYER ACKNOWLEDGES THAT THE SOLAR MODULES TO BE INSTALLED ITEM I OTY I MFR. MODEL ON THE ROOF OF THE HOME WILL BE SUBSTANTIALLY IN THE SYSTEM SIZE 3.18 KW LOCATIONS INDICATED BY THE ILLUSTRATION. MODULE 12 PCS. HYUNDAI HIS-S265RG(265W) BUYER: INVERTER 12 PCS. ENPHASE M215-60-2LL-S22-IG ROOF TYPE TILE W1 COMPOSITE SHINGLE UNDER ARRAY DATE: SUB-ARRAY INFORMATION ARRAY#1 ARRAY#2 ARRAY#3 I ")' C' M MOD OTY 12 NA NA BUYER: g� r TILT 23° NA° NA° Glty Ot Menlfee DATE: ..�tLDI 8l7 AZIMUTH 176° NA° 12 guildinq Dept l"AN APPI JUN 2 3 20i� R Ce1`lF�e "%1i;E° E e p Dval ithes prowl c ,any 29'-B-ARRAY "piation ands 8' L, 30'-6-FLASHING i,)r5lte Un II COnTI _ I I � I I f � I I I I � SOLADECK WIRE ——— TRANSITION BOX (UNDER ARRAY) I I I PV AC DISCONNECT EXTERIOR-GARAGE UTILITY METER 8 MAIN SERVICE PANEL -———_—___ —————__—- (VERIFIED BY BUILDER) NOTE:DIMENSIONS ARE SHOWN IN PLANE OF ROOF N PLAN 27B5 ELEVATION A-REVERSE 0 IEN A ION LO #I e CAMELLIA AT LENNAR: ORIGINAL BY: DESIREE WILLIAMS DATE:16.4.14 980 MONTECITO DRIVE.#302 REVIEWED BY:SHAUN MARUNA DATE:I6.4.14 THE LAKES CORONA.CA 92879 REV.# BY DATE DESCRIPTION namast* SOLAR DWG TITLE: PAGE#: SCALE: SITE LOCATION: 4571 Broads INDIVIDUAL 29621 ARGYLE CIRCLE Boulder,CO Broadway PLOT PLAN 1 I/16'=V-0- MENIFEE.CA 303.447.0300 SYSTEM LAYOUT MODULE SPECS AND CALCULATIONS INVERTER SPECS AND CALCULATIONS ITEM NOTE/CALC UNIT DETAIL ITEM NOTE/CALC UNIT DETAIL LOCATION MENIFEE,CA INV.MAKE INVERTER SPEC ENPHASE TEMP.AMBIENT HIGH(TMAX) ASHRAE 2% °C 37 INV. MODEL INVERTER SPEC M215-60-2LL-SZ2-IG TEMP,AMBIENT LOW(THIN) ASHRAE EXTR.MIN •L -2 INV. MAX POWER,(WAD MAX) INVERTER SPEC WATTS(At) 225 TEMP.MODULE TEST(TTEST) MODULE SPEC •C 25 INV. INPUT V.(Voc MAX) INVERTER SPEC VOLTS(oc) 48 TEMP,DELTA LOW(TOELTA) THIN-TTEST •C -27 INV. OUTPUT V.(Vac NOM) INVERTER SPEC VOLTS(At) 240 MOD.MANUFACTURER MODULE SPEC HYUNDAI INV.OUTPUT FREQUENCY INVERTER SPEC HERTZ 60 MOD.PART NUMBER MODULE SPEC HIS-S265RG INV.OUTPUT CURRENT, Inc INVERTER SPEC AMPS(AC) 0.9 FEE MOD.POWER STC(P) MODULE SPEC WATTS(oc) 265 INV.PHASE QUANTITY INVERTER SPEC PHASE I �� MOD.POWER PTC MODULE SPEC WATTS(oc) 238 COMPLIANCE INVERTER SPEC UL1741/IEEE 7 . MOD.OPERATING VOLTAGE(VMP) MODULE SPEC VOLTS(DC) 31.30 INV.GROUNDING INVERTER SPEC ISOLATED MOD. OPEN CCT. VOLTAGE(Voc) MODULE SPEC VOLTS(ot) 38.10 INV.QTY.MAX/BRANCH CCT. INV.OTYSC OTY 12 /p MOD. COEFF.VOLT/TEMP(COEF) MODULE SPEC V/°C -0.114 BRANCH CCT. OUTPUT.IMAxot I(IAc•INV.GTY80 AMPS(AC) 10.80 MOD. MAX VOLTAGE(VMAXM00) (VOc+(Ta•COEF)) VOLTS Inc) 41.18 INV.QUANTITY,TOTAL I INV.QTYT QTY 12 MOD. OPERATING CURRENT(IMP) MODULE SPEC AMPS(00) 8.50 TOTAL SYSTEM OUTPUT,IMAxTs OAOINV.QTYT) AMPS(AC) 10.80 MOD. SHORT CCT.CURRENT(ISO) MODULE SPEC AMPS(ac) 9.00 MOD. MAXIMUM CURRENT(IMAX) 05C- 1,25) AMPS(oc) 11.25 MIN.AMPACITY REG'D,PER NEC (]MAX•1,25) AMPS(oc) 14.06 SERIES FUSE RATING.MAX MODULE SPEC AMPS(00 15 ELECTRICAL EQUIPMENT SCHEDULE KEY GTY MANUFACTURER MODEL NOTES TRADE 1 12 HYUNDAI HIS-S265RG(265W) PV MODULE SOLAR IS shall t be cc 2 12 ENPHASE M215-60-2LL-S22-IG PV INVERTER SOLAR 10n of an rOVI51 3 1 RSTC/SOLADECK 0786-3R5 PV ROOF JUNCTION BOX,NEMA 3R SOLAR 4 1 CUTLER-HAMMER DG221URB PV AC DISCONNECT,NEMA 3R.24OV.30A SOLAR antes, Tt s set of 5 1 ENPHASE ENVOY PV DATA MONITOR,120V SOLAR 6 1 TBD TBD 120V DEDICATED RECEPTACLE FOR ENVOY PV DATA MONITOR SOLAR )n 7 1 TBD TBD LAT5 PORT FOR SOLAR PV INTERNET CONNECTION TO HOME NETWORK BOX SOLAR 8 NOTE CUTLER-HAMMER TBD PV BRANCH CIRCUIT BREAKERS:I x ISA-IP(ENVOY) SOLAR 9 NOTE CURER-HAMMER TBD PV BREAKER,I A 20A-2P,LOCATE AT OPPOSITE END OF BUS FROM MAIN BREAKER SOLAR 10 I TBD TBD SERVICE PANEL,MIN. 125A BUS BLDR. ELEC. II I TBD TBD UTILITY METER.IPH, 120/240V.200A BLDR. ELEC. 12 11 1 TBD I TBD I GROUNDING ELECTRODE UFER I BLDR.ELEC. CONDUCTOR SIZING CALCULATIONS INTERCONNECTION CALCULATIONS D CONDITION OF USE(COU): I (AMPACITY TEMP.DERATE•FILL DERATE)9i REO'D VMAX) ITEM UNIT PANEL 2)TERMINALS(TERM): AMPACITY AT TERMINALS. Vs.REQ'D,(]MAX• 1.25) PANEL HER. CUTLER-HAMMER KEY SIZE CU/AL INSULATION CALC. AMPACITY W/O TEMP. FILL RESULT REO'D OCO BUS RATING AMPS 200 TYPE DEBATES DERATE DERATE (A) (A) USED(A) MAIN DISCONNECT AMPS 200 A #12 CU THWN-2 COU 30 0.76 1.0 22.80 10.80 ALLOWED PV PER NEC AMPS 40 TERM 25 25 13.50 20 PV OCPD DEVICE USED AMPS 20 B #10 CU NM-S COU 40 0.91 1.0 36.40 10.80 TERM 35 35 13.50 20 C #10 LU NM-B COU 40 0.91 1.0 36.40 10.80 TERM 35 35 13.50 20 CONDUCTOR SCHEDULE KEY CONDUCTORS CU/AL TYPE LOCATION TRADE A 1-#12 ENGAGE CABLE.I-#6G,FREE AIR ICU TC-ER ARRAY SOLAR B 3-#I0, 1-#10 EGC I Cu I NM-B(ROMEX) I INTERIOR ISOLAR C 1 3-#10, 1-#10 EGL I Cu I NM-B(ROMEX) I INTERIOR I SOLAR D I CATSE.ETHERNET CABLE I Cu I CATSE I INTERIOR I SOLAR 5 © 11 7 • L� o � M - SEE NOTE 15 10 O Isaw O O F44O9 F 3 'N G G G� A B L ROOF EXTERIOR-GARAGE ELECTRICAL DIAGRAM 3.18 KW LOT#128 ORIGINAL BY: DESIREE WILLIAMS DATE:16.4.14 CAMELLIA AT LENNAR: 900 MONTECITO DRIVE,#302 REVIEWED BV:SHAUN MARUNA I DATE:16.4.14 THE LAKES CORONA,CA 92879 REV.# BY DATE DESCRIPTION namasbd SOLAR DWG TITLE: PAGE#: SCALE: SITE LOCATION: INDIVIDUAL 457T 1d r,CO 8 Street PLOT PLAN 2 NTS 29621 ARGYLE CIRCLE Bo303. 7.03DO 4 ELECTRICAL MENIFEE,CA 303.447.0300 STRUCTURAL NOTES: SOLAR CONTRACTOR- S ALL PV ROOF ATTACHMENTS WILL BE SPACED ALONG MODULE RACKING RAILS AT NOT GREATER THAN a'O.C. 2)ALL PV ROOF ATTACHMENTS WILL BE STAGGERED BY ROW AMONGST THE ROOF FRAMING MEMBERS.TO MAXIMUM EXTENT POSSIBLE. 3)ROOF PENETRATIONS ASSOCIATED WITH SOLAR RACKING WILL BE SEALED WITH AN APPROVED SEALANT. A)SOLADECK WIRE TRANSITION BOX WILL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS. IT WILL BE FLASHED AND SEALED. 5)PV ARRAY WILL BE A MINIMUM OF 3'ABOVE THE COMPOSITE SHINGLE ROOF SURFACE. 6)THE UNIRAC SOLARMOUNT RACKING SYSTEM AND SOLAR PV ARRAY WILL BE INSTALLED ACCORDING TO THE UNIRAC SOLARMOUNT CODE-COMPLIANT INSTALLATION 7)ON RAC TOP VERSION CLAMPS REQUIRE A ONE INCHU(A)SPACE BETWEEN PV MODULES.SOLARMOUNT RAILS MUST EXTEND A MINIMUM OF TWO.INCHES(2-)BEYOND THE EI5pART EN1 OF THE PV ARRAY/SUB-ARRAY. 8)UNIRAC SOLARMOL94T REQUIRES THAT A THERMAL EXPANSION GAP BE INSTALLED FOR ANY RAIL LENGTH OF GREATER.THAN 40'. ROOFING CONTRACTOR- 0 DISTANCE BETWEEN ARRAY EDGE AND TRANSITION FLASHING(COMPOSITION TO TILE)WILL BE A MINIMUM OF 3'. 2)26 GAUGE INTERLOCKING FLASHING'SIDEWALL'TO BE INSTALLED ALONG THE LENGTH OF THE PV ARRAY AT ROOFING MATERIAL TRANSITION. IT SHALL BE APROVED PRIOR TO PV SYSTEM INSTALLATION. 3)PEEL-N-STICK BASE TO BE INSTALLED ONE FOOT(19 OR MORE BEYOND THE EDGE OF THE COMPOSITION SHINGLE.DOWN TO THE ROOF EAVE.PEEL-N-STICK B BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS. ;EAVE 4)AREAS UNDER EACH PV ARRAY SHALL BE ROOFED WITH COMPOSITION SHINGLE.COMPOSITION SHINGLE SHALL RL94 FROM ABOVE THE PV ARRAY TO THE ROOF 5)TILE INSTALLED BELOW THE ARRAY TO BE INSTALLED ABOVE THE COMPOSITION ROOF PER ROOFER SPECIFICATIONS. 6)BIRDSTOP WILL BE INSTALLED AT THE UPPERMOST TRANSITION FROM TILE TO COMPOSITION SHINGLE. BIRDSTOP TO BE SPECIFIED BY ROOFER PRIOR TO INSTALLATION. u,.dtobea ermitfo Df the feder ii,state o roved plans 1just be I ELECTRICAL NOTES: GENERAL- S ALL PV EQUIPMENT WILL BE TESTED AND LISTED FOR ITS USE BY A NATIONALLY RECOGNIZED TESTING LABORATORY(NRTL). 2)THE GROUNDING OF THE PHOTOVOLTAIC SYSTEM SHALL COMPLY WITH THE APPLICABLE VERSION OF THE NEC/CEC. 3)ALL GROUNDING ELECTRODE CONDUCTORS WILL BE INSTALLED IN A CONTINUOUS LENGTH EXCEPT WHERE SPLICED BY AN IRREVERSIBLE CONNECTOR OR EXOTHERMIC WELD. 4)NON-CURRENT CARRYING METAL PARTS SHALL BE CHECKED FOR PROPER GROUNDING.NOTING THAT TERMINAL LUGS BOLTED ON AN ENCLOSURE'S FINISHED SURFACE MAY BE ELECTRICALLY INSULATED BECAUSE OF PAINT/FINISH. PAINT/FINISH AT POINT OF CONTACT SHALL BE PROPERLY REMOVED. 5)ROOF PENETRATIONS WILL BE COMPLETED AND SEALED PER APPLICABLE CODE. 6)ALL CONDUCTORS WILL HAVE A 90-C RATING TO ENSURE CODE COMPLIANCE. SOLAR CONTRACTOR- 7)MODULE CERTIFICATIONS WILL INCLUDE UL1703,IEC61646, IEC61730. 8)CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS. 9)RACEWAY POINT OF PENETRATION FROM EXTERIOR TO INTERIOR WILL BE SEALED TO PREVENT INGRESS OF WATER AND INSECTS. 10)DC WIRING IS LIMITED TO PV ARRAY FOOTPRINT W/ENPHASE MICRO-INVERTER SYSTEM. ID MODULE AND ENPHASE WIRING SHALL BE LOCATED AND SECURED UNDER THE ARRAY USING SUITABLE WIRING CLIPS.WIRING SHALL NOT MAKE CONTACT WITH THE ROOF SURFACE AND SHALL BE MANAGED IN A WORKMAN-LIKE MANNER. 12)EQUIPMENT GROUNDING CONDUCTORS WILL BE SIZED IN ACCORDANCE WITH NEC TABLE 250.122. 13)CONDUCTOR TERMINATIONS WILL BE TORQUED PER DEVICE LISTING,OR MANUFACTURER'S RECOMMENDATIONS. 14)A PV AGGREGATION PANEL(SUB PANEL)WILL NOT BE INCLUDED FOR SYSTEMS WITH ONE BRANCH CIRCUIT. 15)A DEDICATED 120V BRANCH CIRCUIT IS REQUIRED IN MASTER CLOSET(OR EQUIVALENT)FOR ENPHASE ENVOY MONITOR. SIGNAGE- 16)PV SYSTEMS SHALL BE CLEARLY MARKED IN ACCORDANCE WITH NEC ARTICLE 690 AND OTHER APPLICABLE STATE AND LOCAL CODES. 17)ALL SAFETY MARKING/PLACARDS SHALL BE PERMANENTLY ATTACHED BY ADHESIVE OR OTHER MECHANICAL HEMS. 18)MARKING/PLACARDS WILL BE METAL OR PLASTIC WITH ENGRAVED OR MACHINE PRINTED LETTERING. BACKGROUND WILL BE RED WITH WHITE CAPITAL LETTERING OF MINIMUM HEIGHT t- 19)ALL WIRING/RACEWAYS/JUNCTION BOXES WILL BE MARKED'PHOTOVOLTAIC POWER SOURCE;OR EQUIVALENT;WIRING/RACEWAYS SHALL BE MARKED EVERY 10'. BUILDER ELECTRICAL AND SOLAR CONTRACTORS- 20)INSTALLATION SHALL BE COMPLETED IN A NEAT AND WORKMAN-LIKE MANNER. 21)SPACE REQUIREMENTS FOR ALL ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110,26. LENNAR: ORIGINAL BY: DESIREE WILLIAMS DATE:16.4.1E CAMELLIA AT REVIEWED BY: SHAUN MARLPIA DATE:16.4.14 THE LAKES CORONA,80 A92117CITO RIVE.tl302 CORONA,CA 92879 REV.# BY DATE DESCRIPTION namasCe WlA\ DWG TITLE: PAGE k: SCALE: SITE LOCATION: C571 Broadway Street INDIVIDUAL 29621 ARGYLE CIRCLE Boulder,CO 80806 PLOT PLAN 3 NTS MENIFEE,CA NOTES 3IX1.447.0300 CAUTION: POWER TO THIS BUILDING IS SUPPLIED BY THE UTILITY AND A SOLAR PV SYSTEM. DISCONNECTS ARE LOCATED AS SHOWN. Orl A ;ATE an on the SOLADECX WIRE TRANSITION BOX (UNDER ARRAY) PV AC DISCONNECT EXTERIOR-GARAGE UTILITY METER B MAIN SERVICE PANEL (VERIFIED BY BUILDER) SERVICE BY QUALIFIED PERSONNEL ONLY CONTACT: SUNSTREET ENERGY GROUP 1-877-SLR-POWR PV POWER SOURCE — AC SPECS AC OPERATING VOLTAGE: 240 V AC OPERATING CURRENT: Io.8 A NOTE: SEE MASTER SET FOR ADDITIONAL PLACARD INFORMATION ORIGINAL BY: DESIREE WILLIAMS I DATE:16.4.I4 CAMELLIA AT LENNAR: 98D MONTECITO DRIVE.#302 REVIEWED BY:SHAUN MARUNA DATE:16.4.14 THE LAKES CORONA.CA 92879 REV.# BY DATE DESCRIPTION Vnanniast;6 r;oLAe DWG TITLE: PAGE#: SCALE: SITE LOCATION: 0Bo BroBCINDIVIDUAL04 PLOT PLAN 4 NTS 29621 ARGYLE CIRCLE Boulder,C0008006 PLACARDS MENIFEE,LA 303.467.0300