PMT16-01953 City of Menifee Permit No.: PMT16-01953
29714 HAUN RD. Type: Residential Electrical
<A—CCELA. MENIFEE,CA 92586
MENIFEE Date Issued: 07/2212016
PERMIT
Site Address: 29633 ARGYLE CIR, MENIFEE,CA 92584 Parcel Number: 364-360-036
Construction Cost: $7,650.40
Existing Use: Proposed Use:
Description of SOLAR TR 30422-3 CAMELLIA
Work: 11 MODULES 2.92KW
LOT 127
Owner Contractor
LENNAR HOMES OF CA LENNAR HOMES OF CALIFORNIA INC
980 MONTECITO DR#302 25 ENTERPRISE
CORONA, CA 92879 ALISO VIEJO, CA 92656
Applicant Phone:9493498269
JEREMIAH ACAYTURRI License Number:728102
LENNAR HOMES OF CALIFORNIA INC
25 ENTERPRISE
ALISO VIEJO,CA 92656
Fee Description Amount
Solar, Residential or Small Commercial 1 252.00
Building Permit Issuance 1 27.00
GREEN FEE 1 1.00
SMIP RESIDENTIAL 1 1.00
General Plan Maintenance Fee-Electrical 1 12.60
$293.60
The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and
specifications or from preventing builiding operations being carded on thereunder when in violation of the Building Code or of any other
ordinance of City of Menifee.Except as otherwise stated,a permit for construction under which no work is commenced within six
months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be
forfeited.
AA_Bld9 Permit_Template.rpt Page 1 of 1
BUILDING & SAFETY PERMIT/PLAN CHECK APPLICATION
s-
Menifee
A
DATE 06/15/2016 PERMIT/PLAN CHECK NUMBERRLAM I-l 3
TYPE: ❑COMMERCIAL ❑✓ RESIDENTIAL ❑MULTI-FAMILY ❑MOBILEHOME ❑POOL/SPA ❑SIGN
SUBTYPE: ❑✓ ADDITION []ALTERATION [—]DEMOLITION ❑ELECTRICAL El MECHANICAL
❑NEW ❑PLUMBING [—IRE-ROOF-NUMBER OF SQUARES
DESCRIPTION OF WORK Solar Permit-Plan 2399-2.92 kW/11 PCS
Master Solar Permit: PMT14-02630
PROJECTADDRESS 29633 Argyle Circle., Menifee, CA 92584
ASSESSOR'S PARCEL NUMBER �GN-36o- 03�' LOT 127 TRACT 30422-3
PROPERTY OWNER'S NAME Lennar Homes of California, Inc.
ADDRESS 980 Montecito Dr.,Suite 302, Corona, CA 92879
PHONE (951)817-3680 EMAIL Jeremiah.acayturri@lennarcom
APPLICANT NAME Lennar Homes of California, Inc.
ADDRESS 980 Montecito Dr.,Suite 302, Corona, CA 92879
PHONE (951)817-3680 EMAIL jeremiah.acayturri@lennar.com
CONTRACTOR'S NAME Lennar Homes of California, Inc. OWNER BUILDER? ❑✓ YES❑NO
BUSINESS NAME Lennar Homes of California, Inc.
ADDRESS 980 Montecito Dr.,Suite 302, Corona, CA 92879
PHONE (951)817-3680 EMAIL jeremiah.acayturri@lennar.com
CONTRACTOR'S STATE LIC NUMBER 728102 LICENSE CLASSIFICATION A&B
VALUATION$ $7,650.40 SQ FT L SO,FT
APPLICANT'S SIGNATURE DATE 06/15/2016
CITY STAFF USE ONLY
CITY OF MENIFEE BUSINESS LICENSE NUMBER
BUILDING PLANNING ENGINEERING FIRE GREEN SMIP
INVOICE �/ O PAIDAMOUNT
AMOUNT O CASH O CHECK# O CREDIT CARD VISA/MC
PLAN CHECK FEES PAID AMOUNT O CASH O CHECK# O CREDrr CARD VISA/MC
OWNER BUILDER VERIFIED O YES O NO DL NUMBER NOTARIZED LETTER O YES O NO
City of Menifee Building&Safety Department 29714 Haun Rd. Menifee, CA 92586 951-672-6777
www.cityofinenifee.us Inspection Request Line 951-246-5213
SYSTEM INFORMATION BUYER ACKNOWLEDGES THAT THE SOLAR MODULES TO BE INSTALLED
ITEM OTY MFR. MODEL ON THE ROOF OF THE HOME WILL BE SUBSTANTIALLY IN THE
SYSTEM SIZE 2.92 KW LOCATIONS INDICATED BY THE ILLUSTRATION.
MODULE 1 II PCS.I HYUNDAI I HIS-S265RG(265W) BUYER:
INVERTER 1 II PCS.I ENPHASE I M215-60-2LL-S22-IG CI I Y OF ME IFE
ROOF TYPE I TILE W/COMPOSITE SHINGLE UNDER ARRAY DATE:
SUB-ARRAY INFORMATION BUILDING AND
ARRAY#I 1 ARRAY#2 ARRAY#3
MOD OTY II NA NA BUYER: PPR VA
TILT 23° NA' NA'
AZIMUTH 176- NA' NA' City of Menifee DATE:
Building Dept
JUN 2 3 2016 (REVIEWED 110
Received 'Approval of these pl 3ns sha
approval of,any violation of
regulations and ordin nces.
jobs ite until completion.
19'-9'ARRAY
20'-T FLASHING 6`9''
I 1
I
I -
I I
I I
I I
SOLAOECN WIRE L �
TRANSITION BOX I i
(UNDER ARRAY)
I I I
PV AC DISCONNECT
EXTERIOR-GARAGE ——————-
I
� I
UTILITY METER B
MAIN SERVICE PANEL ——
(VERIFIED BY BUILDER)
- tgb
197,
NOTE:DIMENSIONS ARE SHOWN IN PLANE OF ROOF
N
PLAN 2399 ELEVATION C
ORIENTATION 3 TM7727
: ORIGINAL BY: DESIREE WILLIAMS DATE:16.4.14
CAMELLIA AT LENNAR
980 MONTECITO DRIVE.#302 REVIEWED BY:SHAUN MARUNA DATE:I6.4.I4
THE LAKES CORONA,CA 92879 REV.# BY DATE I DESCRIPTION
to namastB
DWG TITLE: PAGE#: SCALE: SITE LOCATION:
INDIVIDUAL 457t Broadway Street
2ENIF ARGYLE CIRCLE Boulder,C7.80804
PLOT PLAN /I6'=I'-0' MENIFEE,CA 303.447.0300
SYSTEM LAYOUT
MODULE SPECS AND CALCULATIONS INVERTER SPECS AND CALCULATIONS
ITEM NOTE/CALC UNIT DETAIL ITEM NOTE/CALC UNIT DETAIL
LOCATION MENIFEE.CA INV. MAKE INVERTER SPEC ENPHASE
TEMP,AMBIENT HIGH UMAX) ASHRAE 2% °C 37 INV. MODEL INVERTER SPEC M215-60-2LL-S22-IG
TEMP,AMBIENT LOW(THIN) ASHRAE EXTR.MIN °C -2 INV. MAX POWER.(WAG MAX) INVERTER SPEC WATTS(AC) 225
TEMP,MODULE TEST(TTEST) MODULE SPEC °C 25 INV. INPUT V.(Vnc MAX) INVERTER SPEC VOLTS(cc) 48
TEMP,DELTA LOW(TOELTA) THIN-TTEST °C -27 INV.OUTPUT V.(VAC NOM) INVERTER SPEC VOLTS(AC) 240 DEI
MOD.MANUFACTURER MODULE SPEC HYUNDAI INV.OUTPUT FREQUENCY INVERTER SPEC HERTZ 60
MOD.PART NUMBER MODULE SPEC HIS-S265RG INV.OUTPUT CURRENT, IAC INVERTER SPEC AMPS(AC) 0.9
MOD.POWER STC(P) MODULE SPEC WATTS(cc) 265 INV.PHASE QUANTITY INVERTER SPEC PHASE I
MOD.POWER PTC MODULE SPEC WATTS(cc) 23B COMPLIANCE INVERTER SPEC UL1741/IEEtcorl
MOD.OPERATING VOLTAGE(VMP) MODULE SPEC VOLTS(cc) 31.30 INV.GROUNDING INVERTER SPEC ISOLATED
MOD.OPEN CCT. VOLTAGE(Voc) MODULE SPEC VOLTS(cc) 38.10 INV.OTY.MAX/BRANCH CCT. INTQTYBc OTY II
MOD.COEFF. VOLT/TEMP(COEF) MODULE SPEC V/°C -0.114 BRANCH CCT. OUTPUT,IMAXBc (IAC°INV.QTYeCJ AMPS(Ac) 9.90
MOD.MAX VOLTAGE(VMAXMOo) (VOc♦(To°COEF)) VOLTS(cc) 41.18 INV.QUANTITY,TOTAL INV.QTYT OTY II
MOD.OPERATING CURRENT(IMP) MODULE SPEC AMPS(GC) B.50 TOTAL SYSTEM OUTPUT,WARTS (IAC°INV.GTYT) AMPS(AC) 9.90
MOD.SHORT CCT.CURRENT(ISO MODULE SPEC AMPS(cc) 9.00
MOD.MAXIMUM CURRENT(IMAX) (Isc°1.25) AMPS(cc) 11.25
MIN.AMPACITY REQ'D,PER NEC (IMAX° 1.25) AMPS(Cc) 14.06
SERIES FUSE RATING,MAX MODULE SPEC AMPS(cc) 15
ELECTRICAL EQUIPMENT SCHEDULE I L,vlsiur softhe
KEY OTY MANUFACTURER MODEL NOTES TRADE of roved
1 11 HYUNDAI HIS-S265RG(265W) PV MODULE SOLAR
2 11 ENPHASE M215-60-2LL-S22-IG PV INVERTER SOLAR
3 1 RSTC/SOLADECK 0786-3R5 PV ROOF JUNCTION BOX,NEMA 3R SOLAR
4 1 CUTLER-HAMMER DG221URB PV AC DISCONNECT,NEMA 3R,24OV.30A SOLAR
5 1 ENPHASE ENVOY PV DATA MONITOR,120V SOLAR
6 1 TBD TBD 120V DEDICATED RECEPTACLE FOR ENVOY PV DATA MONITOR SOLAR
7 1 TBD TBD CATS PORT FOR SOLAR PV INTERNET CONNECTION TO HOME NETWORK BOX SOLAR
8 NOTE CUTLER-HAMMER TBD PV BRANCH CIRCUIT BREAKERS:I x ISA-IP(ENVOY) SOLAR
9 NOTE CUTLER-HAMMER TBD PV BREAKER, I x 20A-2P,LOCATE AT OPPOSITE END OF BUS FROM MAIN BREAKER SOLAR
IO I TBD TBD SERVICE PANEL.MIN. 125A BUS BLDR.ELEC.
II I TBD TBD UTILITY METER,IPH,120/24OV,200A BLOR.ELEC.
12 1 I 1 TBD I TBD I GROUNDING ELECTRODE UFER BLDR.ELEC.
CONDUCTOR SIZING CALCULATIONS INTERCONNECTION CALCULATIONS
1)CONDITION OF USE(COU): (AMPACITY°TEMP.DERATE°FILL DERATE) vs.REO'D(IMAx) ITEM UNIT PANEL
2)TERMINALS(TERM): AMPACITY AT TERMINALS. vs.REG'O,(IN"= 1.25) PANEL MFR. CUTLER-HAMMER
KEY SIZE CU/AL INSULATION CALC. AMPACITY W/O TEMP. FILL RESULT REO'D OCD BUS RATING AMPS 200
TYPE DERATES DERATE DERATE (A) (A) USED(A) MAIN DISCONNECT AMPS 200
A #12 CU THWN-2 COU 30 0.76 1 1.0 22.80 9.90 ALLOWED PV PER NEC AMPS 40
TERM 25 1 25 12.38 20 PV OCPD DEVICE USED AMPS 20
B #10 CU NM-B COU 40 0.91 1 1.0 36.40 9.90
TERM 35 35 12.38 1 20
C #10 CU NM-B COU 40 0.91 L0 36.40 9.90
TERM 35 35 12.38 20
CONDUCTOR SCHEDULE
KEY 1 CONDUCTORS CU/AL TYPE LOCATION TRADE
q -#12 ENGAGE CABLE,I-#5G.FREE AIR CU TC-ER ARRAY SOLAR
B I 3-#10,1-#10 EGC I CU I NM-B(ROMEX) INTERIOR SOLAR
C 1 3410.1-#10 EGC I CU I NM-B(ROMEX) INTERIOR I SOLAR
p I CAT5E,ETHERNET CABLE I CU I CAT5E INTERIOR I SOLAR
5 6
7 • o u
M —
SEE NOTE 15 10
O O O L-ILO
N
G
A B C =12
RGGF EXTERIOR-GARAGE
ELECTRICAL DIAGRAM 2.92 KW
LOT#127
ORIGINAL BY: DESIREE WILLIAMS I DATE:16.4.14
CAMELLIA AT LENNAR:
980 MONTECITO DRIVE,#302 REVIEWED BY:SHAUN MARUNA I DATE:16.4.14
THE LAKES CORONA,CA 92879 REV.# BY I DATE I DESCRIPTION
Vnamast;(3
SOLAR
DING TITLE: PAGE#: SCALE: SITE LOCATION:
INDIVIDUAL 4571 BraaAvay 56eat
PLOT PLAN 2 NTS 29633 ARGYLE CIRCLE Boultlec CO 00304
ELECTRICAL MENIFEE,CA 303.447.03G0
STRUCTURAL NOTES:
SOLAR CONTRACTOR-
1)ALL PV ROOF ATTACHMENTS WILL BE SPACED ALONG MODULE RACKING RAILS AT NOT GREATER THAN 48'O.C.
2)ALL PV ROOF ATTACHMENTS WILL BE STAGGERED BY ROW AMONGST THE ROOF FRAMING MEMBERS,TO MAXIMUM EXTENT POSSIBLE.
3)ROOF PENETRATIONS ASSOCIATED WITH SOLAR RACKING WILL BE SEALED WITH AN APPROVED SEALANT.
4)SOLADECK WIRE TRANSITION BOX WILL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS. IT WILL BE FLASHED AND SEALED.
5)PV ARRAY WILL BE A MINIMUM OF 3'ABOVE THE COMPOSITE SHINGLE ROOF SURFACE. �(�
6)THE UNIRAC SOLARMOUNT RACKING SYSTEM AND SOLAR PV ARRAY WILL BE INSTALLED ACCORDING TO THE UNIRAC SOLARMOUNT CODE-COMPLIANT INSTALLATION MGEP
MANUAL,VERSION 227.3,PUB 140113-ICC,JANUARY 2014.
7)UNIRAC TOP CLAMPS REQUIRE A ONE INCH(I-)SPACE BETWEEN PV MODULES.SOLARMOUNT RAILS MUST EXTEND A MINIMUM OF TWO INCHES(7)BEYOND THE EDGE
OF THE PV ARRAY /SUB-ARRAY.
8)UNIRAC SOLARMOUNT REQUIRES THAT A THERMAL EXPANSION GAP BE INSTALLED FOR ANY RAIL LENGTH OF GREATER THAN 40'.
ROOFING CONTRACTOR-
D DISTANCE BETWEEN ARRAY EDGE AND TRANSITION FLASHING(COMPOSITION TO TILE)WILL BE A MINIMUM OF 3'.
2)26 GAUGE INTERLOCKING FLASHING'SIOEWALL'TO BE INSTALLED ALONG THE LENGTH OF THE PV ARRAY AT ROOFING MATERIAL TRANSITION. IT SHALL BE
APROVED PRIOR TO PV SYSTEM INSTALLATION.
3)PEEL-N-STICK BASE TO BE INSTALLED ONE FOOT W)OR MORE BEYOND THE EDGE OF THE COMPOSITION SHINGLE,DOWN TO THE ROOF SAVE.PEEL-N-STICK BASE TO
BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS.
4)AREAS UNDER EACH PV ARRAY SHALL BE ROOFED WITH COMPOSITION SHINGLE.COMPOSITION SHINGLE SHALL RUN FROM ABOVE THE PV ARRAY TO THE ROOF SAVE.
5)TILE INSTALLED BELOW THE ARRAY TO BE INSTALLED ABOVE THE COMPOSITION ROOF PER ROOFER SPECIFICATIONS.
6)SIRDSTOP WILL BE INSTALLED AT THE UPPERMOST TRANSITION FROM TILE TO COMPOSITION SHINGLE.BIRDSTOP TO BE SPECIFIED BY ROOFER PRIOR TO ,IPTITIIt fC
INSTALLATION. F Ir 5tate o
ust be I(
ELECTRICAL NOTES:
GENERAL-
U ALL PV EQUIPMENT WILL BE TESTED AND LISTED FOR ITS USE BY A NATIONALLY RECOGNIZED TESTING LABORATORY(NRTL).
2)THE GROUNDING OF THE PHOTOVOLTAIC SYSTEM SHALL COMPLY WITH THE APPLICABLE VERSION OF THE NEC/GEC.
3)ALL GROUNDING ELECTRODE CONDUCTORS WILL BE INSTALLED IN A CONTINUOUS LENGTH EXCEPT WHERE SPLICED BY AN IRREVERSIBLE CONNECTOR OR EXOTHERMIC
WELD.
4)NON-CURRENT CARRYING METAL PARTS SHALL BE CHECKED FOR PROPER GROUNDING,NOTING THAT TERMINAL LUGS BOLTED ON AN ENCLOSURE'S FINISHED SURFACE
MAY BE ELECTRICALLY INSULATED BECAUSE OF PAINT/FINISH. PAINT/FINISH AT POINT OF CONTACT SHALL BE PROPERLY REMOVED.
5)ROOF PENETRATIONS WILL BE COMPLETED AND SEALED PER APPLICABLE CODE.
6)ALL CONDUCTORS WILL HAVE A 90-C RATING TO ENSURE CODE COMPLIANCE.
SOLAR CONTRACTOR-
7)MODULE CERTIFICATIONS WILL INCLUDE UL1703.IEC61646,IEC61730.
8)CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS.
9)RACEWAY POINT OF PENETRATION FROM EXTERIOR TO INTERIOR WILL BE SEALED TO PREVENT INGRESS OF WATER AND INSECTS.
10)DC WIRING IS LIMITED TO PV ARRAY FOOTPRINT W/ENPHASE MICRO-INVERTER SYSTEM.
IU MODULE AND ENPHASE WIRING SHALL BE LOCATED AND SECURED UNDER THE ARRAY USING SUITABLE WIRING CLIPS. WIRING SHALL NOT MAKE CONTACT WITH THE
ROOF SURFACE AND SHALL BE MANAGED IN A WORKMAN-LIKE MANNER.
12)EQUIPMENT GROUNDING CONDUCTORS WILL BE SIZED IN ACCORDANCE WITH NEC TABLE 250.122.
13)CONDUCTOR TERMINATIONS WILL BE TORQUED PER DEVICE LISTING,OR MANUFACTURER'S RECOMMENDATIONS.
14)A PV AGGREGATION PANEL(SUB PANEL)WILL NOT BE INCLUDED FOR SYSTEMS WITH ONE BRANCH CIRCUIT.
15)A DEDICATED 120V BRANCH CIRCUIT IS REQUIRED IN MASTER CLOSET(OR EQUIVALENT)FOR ENPHASE ENVOY MONITOR.
SIGNAGE-
16)PV SYSTEMS SHALL BE CLEARLY MARKED IN ACCORDANCE WITH NEC ARTICLE 690 AND OTHER APPLICABLE STATE AND LOCAL CODES.
17)ALL SAFETY MARKING/PLACARDS SHALL BE PERMANENTLY ATTACHED BY ADHESIVE OR OTHER MECHANICAL MEANS.
18)MARKING/PLACARDS WILL BE METAL OR PLASTIC WITH ENGRAVED OR MACHINE PRINTED LETTERING.BACKGROUND WILL BE RED WITH WHITE CAPITAL LETTERING OF
MINIMUM HEIGHT V
19)ALL WIRING/RACEWAYS/JUNCTION BOXES WILL BE MARKED'PHOTOVOLTAIC POWER SOURCE:OR EQUIVALENT:WIRING/RACEWAYS SHALL BE MARKED EVERY 10'.
BUILDER ELECTRICAL AND SOLAR CONTRACTORS-
20)INSTALLATION SHALL BE COMPLETED IN A NEAT AND WORKMAN-LIKE MANNER.
21)SPACE REQUIREMENTS FOR ALL ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110.26.
LENNAR: ORIGINAL BY: DESIREE WILLIAMS DATE:16.4.14
CAMELLIA AT 980 MONTELITO DRIVE.#302 REVIEWED BY: SHAUN MARLWA DATE:16.4.14
THE LAKES CORONA.CA 92879 REV.# BY DATE DESCRIPTION
Vnamast;d
DWG TITLE: PAGE#: SCALE: SITE LOCATION:
4671 B CO 8 Street
INDIVIDUAL 29633 ARGYLE CIRCLE BO C08D004
303.er,
PLOT PLAN 3 NTS MENIFEE,CA 303.d47.0300
NOTES
CAUTION:
POWER TO THIS BUILDING IS SUPPLIED BY THE
UTILITY AND A SOLAR PV SYSTEM. DISCONNECTS
ARE LOCATED AS SHOWN.
,a
an
y
th
SOLADECK WIRE
TRANSITION BD%
(UNDER ARRAY)
PV AC DISCONNECT
EXTERIOR-GARAGE
UTILITY METER A
MAIN SERVICE PANEL
(VERIFIED BY BUILDER)
SERVICE BY QUALIFIED PERSONNEL ONLY
CONTACT: SUNSTREET ENERGY GROUP
1-877-SLR-POWR
PV POWER SOURCE - AC SPECS
AC OPERATING VOLTAGE: 240 V
AC OPERATING CURRENT: 9.9 A
NOTE: SEE MASTER SET FOR ADDITIONAL PLACARD INFORMATION
LENNAR: ORIGINAL BY: DESIREE WILLIAMS DATE:16.4.14
CAMELLIA AT REVIEWED BY:SHAM MIARUNA DATE:16.4.14
980 MONTECITO DRIVE.#302
CORONA.CA 92879 REV.# BY GATE DESCRIPTION
THE LAKES VnarnastI6
roue
DWG TITLE: PAGE#: SCALE: SITE LOCATION: 4571 B=dway Street
INDIVIDUAL 4 NTS 29633 ARGYLE CIRCLE Bodder,CO 803O4
PLOT PLAN MENIFEE,CA 303.447.0300
PLACARDS