Loading...
PMT16-01948 City of Menifee Permit No.: PMT16-01948 29714 HAUN RD. SnCCEL/-> MENIFEE,CA 92586 Type: Residential Electrical MENIFEE Date Issued: 0 7/2 212 01 6 PERMIT Site Address: 29705 ARGYLE CIR,MENIFEE,CA 92584 Parcel Number: 364-360-031 Construction Cost: $7,650.40 Existing Use: Proposed Use: Description of SOLAR TR 30422-3 CAMELLIA Work: 11 MODULES 2.92KW LOT 122 Owner Contractor LENNAR HOMES OF CA LENNAR HOMES OF CALIFORNIA INC 980 MONTECITO DR#302 25 ENTERPRISE CORONA,CA 92879 ALISO VIEJO, CA 92656 Applicant Phone:9493498269 JEREMIAH ACAYTURRI License Number.728102 LENNAR HOMES OF CALIFORNIA INC 25 ENTERPRISE ALISO VIEJO, CA 92656 Fee Description Ply Amount fE1 Solar,Residential or Small Commercial 1 252.00 Building Permit Issuance 1 27.00 GREEN FEE 1 1.00 SMIP RESIDENTIAL 1 1.00 General Plan Maintenance Fee-Electrical 1 12.60 $293.60 The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and specifications or from preventing builiding operations being carded on thereunder when in violation of the Building Code or of any other ordinance of City of Menifee.Except as otherwise stated,a permit for construction under which no work is commenced within six months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be forfeited. AA_Bldg_Permit Template.rpt Page 1 of 1 BUILDING • SAFETY PERMIT/PLANAPPLICATION h: ,&Menifee DATE 06/15/2016 PERMIT/PLAN CHECK NUMBER TYPE: ❑COMMERCIAL ❑✓ RESIDENTIAL ❑MULTI-FAMILY ❑MOBILEHOME ❑POOL/SPA ❑SIGN SUBTYPE: ❑✓ ADDITION []ALTERATION ❑DEMOLITION ❑ELECTRICAL []MECHANICAL ❑NEW []PLUMBING ❑RE-ROOF-NUMBER OF SQUARES DESCRIPTION OF WORK Solar Permit-Plan 2399-2.92 kW/11 PCS Master Solar Permit: PMT14-02630 PROJECT ADDRESS 29705 Argyle Circle., Menifee,CA 92584 ASSESSOR'S PARCEL NUMBER 36q - 360 -031 LOT 122 TRACT 30422-3 PROPERTY OWNER'S NAME Lennar Homes of California, Inc. ADDRESS 980 Montecito Dr.,Suite 302, Corona,CA 92879 PHONE (951)817-3680 EMAIL jeremiah.acayturri@lennar.com APPLICANT NAME Lennar Homes of California, Inc. ADDRESS 980 Montecito Dr.,Suite 302, Corona,CA 92879 PHONE (951)817-3680 EMAIL jeremiah.acayturri@lennar.com CONTRACTOR'S NAME Lennar Homes of California, Inc. OWNER BUILDER? ❑✓ YES❑NO BUSINESS NAME Lennar Homes of California, Inc. ADDRESS 980 Montecito Dr.,Suite 302, Corona, CA 92879 PHONE (951)817-3680 EMAIL jeremiah.acayturri@lennar.com CONTRACTOR'S STATE LIC NUMBER 728102 LICENSE CLASSIFICATION A&B VALUATION $ $7,650.40 S L SO FT APPLICANT'S SIGNATURE DATE 06/15/2016 DEPARTMENT DISTRIBUTION VO I CITY OF MENIFEE BUSINESS LICENSE NUMBER BUILDING PLANNING ENGINEERING FIRE GREEN (00 SMIP INVOICE �� PAIDAMOUNT AMOUNT O�"��! OCASH OCHECK# :'CREDIT CARD VISA/MC PLAN CHECK FEES PAID AMOUNT ^CASH O CHECK# O CREDITCARD VISA/MC OWNER BUILDER VERIFIED O YES NO DL NUMBER NOTARIZED LETTER O YES O NO City of Menifee Building&Safety Department 29714 Haun Rd. Menifee, CA 92586 951-672-6777 www.cityofinenifee.us Inspection Request Line 951-246-6213 SYSTEM INFORMATION BUYER ACKNOWLEDGES THAT THE SOLAR MODULES TO BE INSTALLED ITEM DTY MFR. MODEL ON THE ROOF OF THE HOME WILL BE SUBSTANTIALLY IN THE SYSTEM SIZE 2.92 8W I LOCATIONS INDICATED BY THE ILLUSTRATION. MODULE II PCS.I HYUNDAI HIS-S265RG (265W) BUYER: INVERTER II PCS.j ENPHASE I M2I5-50-2LL-S22-IG ROOF TYPE I TILE W/COMPOSITE SHINGLE UNDER ARRAY DATE: SUB-ARRAY INFORMATION ARRAY#I 1 ARRAY#2 ARRAY#3 i.l I Y OF MENIF E MOD OTY II NA NA BUYER: TILT NA• I NA' DATE: FUILDINGAN SAF AZIMUTH 155'55° NA' NA- City of Menifee Building Dept i'LAN APPROV L JUN 2 3 REVIEWED B R e c e I =lpproval of these plans s iall not approval of,any violation if any p r igulations and ordinance 4 This: 19'-9'ARRAY jubsite until completion. 6'-W 20'-7'FLAR = r i i � I -> RANSI WIRE T TRANSITION BOX (UNDER ARRAY) f — PV AC DISCONNECT I EXTERIOR-GARAGE UTILITY METER 8 MAIN SERVICE PANEL (VERIFIED BY BUILDER) L NOTE:DIMENSIONS ARE SHOWN IN PLANE OF ROOF PLAN 2399 ELEVATION B-REVERSE 0 N A ION LO CAMELLIA AT LENNAR: ORIGINAL BY: DESIREE WILLIAMS I DATE:16.4.14 980 MONTECITO DRIVE,#302 REVIEWED 8Y:SHAUN MARUMA I DATE:I6.4.14 THE LAKES CORONA,CA 92079 REV.# BY DATE DESCRIPTION Pnornast;6 DWG TITLE: PAGE#: SCALE: SOLAR SITE LOCATION: 4571 Broadway Street INDIVIDUAL 29705 ARGYLE CIRCLE Boulder.CO 80304 PLOT PLAN I I116'= I'-0' MENIFEE.CA 303.447.0300 SYSTEM LAYOUT MODULE SPECS AND CALCULATIONS INVERTER SPECS AND CALCULATIONS ITEM NOTE/CALC UNIT DETAIL ITEM NOTE/CALC UNIT DETAIL LOCATION MENIFEE,CA INV.MAKE INVERTER SPEC ENPHASE TEMP,AMBIENT HIGH(TMAX) ASHRAE 2% °C 37 INV.MODEL INVERTER SPEC 11215-60-21-L-S22-IG TEMP.AMBIENT LOW(THIN) ASHRAE EXTR.MIN °C -2 INV.MAX POWER,(WAC MAX) INVERTER SPEC WATTS(Ac) 225 TEMP,MODULE TEST(TTEST) MODULE SPEC °C 25 INV. INPUT V.(VOC MAX) INVERTER SPEC VOLTS 00 48 TEMP.DELTA LOW(ToELTA) THIN-TTEST °C -27 INV.OUTPUT V,(VAc NON) INVERTER SPEC VOLTS(AC) 240 MOO.MANUFACTURER MODULE SPEC HYUNDAI INV.OUTPUT FREQUENCY INVERTER SPEC HERTZ 60 MOD.PART NUMBER MODULE SPEC HIS-S265RG INV.OUTPUT CURRENT,AC INVERTER SPEC AMPS(AC) 0.9 MOD.POWER STC(P) MODULE SPEC WATTS(oe) 265 INV.PHASE QUANTITY INVERTER SPEC PHASE I PAS MOD.POWER PTC MODULE SPEC WATTS(00 238 COMPLIANCE INVERTER SPEC UL1741/IEEE1547 MOD.OPERATING VOLTAGE(VMP) MODULE SPEC VOLTS(DC) 31.30 INV.GROUNDING INVERTER SPEC ISOLATED MOD.OPEN CCT.VOLTAGE(VOO) MODULE SPEC VOLTS(130 38.10 INV. OTY.MAX/BRANCH CCT. INTOTYsc1 GTY II MOD.COEFF,VOLT/TEMP(COEF) MODULE SPEC V/°C -0.114 BRANCH CCT.OUTPUT.IMAXBc I(IAC'INV.QTYac) I AMPS(AC) 9.90 MOD.MAX VOLTAGE(VMAXMOO) (Voc+(TO'COEF)) VOLTS We) 41.18 INV. QUANTITY, TOTAL I INV.QTYT I OTY 11 MOD.OPERATING CURRENT(IMP) MODULE SPEC AMPS We) 8.50 TOTAL SYSTEM OUTPUT,IMAXTs I OAC'INV.QTYT) I AMPS(AC) 9.90 MOD.SHORT CCT. CURRENT(Ise) MODULE SPEC AMPS(00 9.00 MOD.MAXIMUM CURRENT(IMAX) (Ise•1.25) AMPS(oU 11.25 MIN.AMPACITY REO'D.PER NEC (IMAX' 1.25) AMPS(00 14.06 SERIES FUSE RATING.MAX MODULE SPEC AMPS(130 IS 46 ELECTRICAL EQUIPMENT SCHEDULE I KEY OTY MANUFACTURER MODEL NOTES TRADE ^HStr ed t0 YI 1 11 HYUNDAI MIS-S265RG(265W) PV MODULE SOLAR 2 11 ENPHASE M215-60-2LL-S22-IG PV INVERTER SOLAR ,IONS thefe( 3 1 RSTC/SOLADECK 0786-3R5 PV ROOF JUNCTION BOX,NEMA 3R SOLAR 4 1 CUTLER-HAMMER DG221URB PV AC DISCONNECT,NEMA 3R,240V.30A SOLAR If appn ived pla 5 1 ENPHASE ENVOY PV DATA MONITOR,120V SOLAR 6 1 TBD TBD 120V DEDICATED RECEPTACLE FOR ENVOY PV DATA MONITOR SOLAR 7 1 TBD TBD CATS PORT FOR SOLAR PV INTERNET CONNECTION TO HOME NETWORK BOX SOLAR 8 NOTE CUTLER-HAMMER TBD PV BRANCH CIRCUIT BREAKERS;I X 15A-IP(ENVOY) SOLAR 9 NOTE CUTLER-HAMMER TBD PV BREAKER,I X 20A-2P.LOCATE AT OPPOSITE END OF BUS FROM MAIN BREAKER SOLAR 10 1 TBD TBD SERVICE PANEL.MIN.125A BUS BLDR.ELEC. II TBO TBD UTILITY METER,IPH.120/24OV,200A BLDR.ELEC, 12 1 1 1 TBD TBD I GROUNDING ELECTRODE UFER BLDR.ELEC. CONDUCTOR SIZING CALCULATIONS INTERCONNECTION CALCULATIONS D CONDITION OF USE(COU): (AMPACITY•TEMP.DERATE•FILL DEBATE) Vs.REO'D(IMAX) ITEM UNIT PANEL 2)TERMINALS(TERM): AMPACITY AT TERMINALS. Vs.REQ'D,(IMAX' 1.25) PANEL MFR. CUTLER-HAMMER KEY SIZE CU/AL INSULATION CALL' AMPACITY W/O TEMP. FILL RESULT REO'D OCD BUS RATING AMPS 200 TYPE DERATES DERATE DERATE (A) (A) USED(A) MAIN DISCONNECT AMPS 200 A #12 CU THWN-2 COU 30 0.76 1.0 22.80 9.90 ALLOWED PV PER NEC AMPS 40 TERM 25 25 12.38 20 PV OCPD DEVICE USED AMPS 20 B #10 CU NM-B COU 40 0.91 1.0 36.40 9.90 TERM 35 35 12.38 1 20 C #10 CU NM-B COU 40 0.91 1.0 36.40 9.90 TERM 35 35 12.38 20 CONDUCTOR SCHEDULE KEY CONDUCTORS 1 CU/AL TYPE 1 LOCATION I TRADE A 1-#12 ENGAGE CABLE.1-#6G,FREE AIR CU TC-ER ARRAY SOLAR B 3-#Q.1-#10 EGC I CU I NM-B(ROMEX) I INTERIOR SOLAR C 1 3-#10.1-#10 EGC I CU NM-B(ROMEX) I INTERIOR I SOLAR D I CAT5E,ETHERNET CABLE I CU CATSE INTERIOR I SOLAR 5 6 II 7 • c u I M - SEE NOTE 15 I IO 0 0 0 Hliliffliliffl 'N GJ A B C =I2 ROOF I EXTERIOR-GARAGE ELECTRICAL DIAGRAM 2.92 KW LOT#122 ORIGINAL BY: DESIREE WILLIAMS DATE:Ifi.4.14 CAMELLIA AT LENNAR: 980 MONTECITO DRIVE,#302 REVIEWED BY:SHAUN MARL24A I DATE:16.4.14 THE LAKES CORONA CA 92879 REV.# BY DATE I DESCRIPTION namaste sou• DWG TITLE: PAGE#: SCALE: SITE LOCATION: 0.Bo Broadway,COStreet INDIVIDUAL 29705 ARGYLE GIRLIE Boulder, 80009 PLOT PLAN 2 NTS ELECTRICAL MENIFEE.CA 03.417.0300 STRUCTURAL NOTES: SOLAR CONTRACTOR- U ALL PV ROOF ATTACHMENTS WILL BE SPACED ALONG MODULE RACKING RAILS AT NOT GREATER THAN 40'O.C. 2)ALL PV ROOF ATTACHMENTS WILL BE STAGGERED BY ROW AMONGST THE ROOF FRAMING MEMBERS,TO MAXIMUM EXTENT POSSIBLE. 3)ROOF PENETRATIONS ASSOCIATED WITH SOLAR RACKING WILL BE SEALED WITH AN APPROVED SEALANT. 4)SOLADECK WIRE TRANSITION BOX WILL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS. IT WILL BE FLASHED AND SEALED. 5)PV ARRAY WILL BE A MINIMUM OF 3'ABOVE THE COMPOSITE SHINGLE ROOF SURFACE. 6)THE UNIRAC SOLARMOUNT RACKING SYSTEM AND SOLAR PV ARRAY WILL BE INSTALLED ACCORDING TO THE UNIRAC SOLARMGUNT CODE-COMPLIANT INSTALLATION MANUAL,VERSION 227.3,PUB 140113-ICC,JANUARY 2014. 7)UNIRAC TOP CLAMPS REQUIRE A ONE INCH(1')SPACE BETWEEN PV MODULES.SOLARMOUNT RAILS MUST EXTEND A MINIMUM OF TWO INCHES(21 BEYOND THE EDGE (� OF THE PV ARRAY/SUB-ARRAY. 8)UNIRAC SOLARMOUNT REQUIRES THAT A THERMAL EXPANSION GAP BE INSTALLED FOR ANY RAIL LENGTH OF GREATER THAN 40'. ROOFING CONTRACTOR.- U DISTANCE BETWEEN ARRAY EDGE AND TRANSITION FLASHING(COMPOSITION TO TILE)WILL BE A MINIMUM OF 21 26 GAUGE INTERLOCKING FLASHING'SIDEWALL'TO BE INSTALLED ALONG THE LENGTH OF THE PV ARRAY AT ROOFING MATERIAL TRANSITION. IT SHALL BE APROVED PRIOR TO PV SYSTEM INSTALLATION. 3)PEEL-N-STICK BASE TO BE INSTALLED ONE FOOT 00 OR MORE BEYOND THE EDGE OF THE COMPOSITION SHINGLE,DOWN TO THE ROOF EAVE.PEEL-N-STICK BASE TO BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS. 4)AREAS UNDER EACH PV ARRAY SHALL BE ROOFED WITH COMPOSITION SHINGLE.COMPOSITION SHINGLE SHALL RUN FROM ABOVE THE PV ARRAY TO THE ROOF EAVE. ' 5)TILE INSTALLED BELOW THE ARRAY TO BE INSTALLED ABOVE THE COMPOSITION ROOF PER ROOFER SPECIFICATIONS. 6)BIRDSTOP WILL BE INSTALLED AT THE UPPERMOST TRANSITION FROM TILE TO COMPOSITION SHINGLE.BIRDSTOP TO BE SPECIFIED BY ROOFER PRIOR TO INSTALLATION. )2rR)It TIUSt b ELECTRICAL NOTES: GENERAL- 1)ALL PV EQUIPMENT WILL BE TESTED AND LISTED FOR ITS USE BY A NATIONALLY RECOGNIZED TESTING LABORATORY(NRTU. 2)THE GROUNDING OF THE PHOTOVOLTAIC SYSTEM SHALL COMPLY WITH THE APPLICABLE VERSION OF THE NEC/CEC. 3)ALL GROUNDING ELECTRODE CONDUCTORS WILL BE INSTALLED IN A CONTINUOUS LENGTH EXCEPT WHERE SPLICED BY AN IRREVERSIBLE CONNECTOR OR EXOTHERMIC WELD. 4)NON-CURRENT CARRYING METAL PARTS SHALL BE CHECKED FOR PROPER GROUNDING.NOTING THAT TERMINAL LUGS BOLTED ON AN ENCLOSURE'S FINISHED SURFACE MAY BE ELECTRICALLY INSULATED BECAUSE OF PAINT/FINISH. PAINT/FINISH AT POINT OF CONTACT SHALL BE PROPERLY REMOVED. 5)ROOF PENETRATIONS WILL BE COMPLETED AND SEALED PER APPLICABLE CODE. 6)ALL CONDUCTORS WILL HAVE A 90-C RATING TO ENSURE CODE COMPLIANCE. SOLAR CONTRACTOR- 7)MODULE CERTIFICATIONS WILL INCLUDE UL1703,IEC61646.IEC61730. 8)CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS. 9)RACEWAY POINT OF PENETRATION FROM EXTERIOR TO INTERIOR WILL BE SEALED TO PREVENT INGRESS OF WATER AND INSECTS. 10)DC WIRING IS LIMITED TO PV ARRAY FOOTPRINT W/ENPHASE MICRO-INVERTER SYSTEM. 11)MODULE AND ENPHASE WIRING SHALL BE LOCATED AND SECURED UNDER THE ARRAY USING SUITABLE WIRING CLIPS.WIRING SHALL NOT MAKE CONTACT WITH THE ROOF SURFACE AND SHALL BE MANAGED IN A WORKMAN-LIKE MANNER. 12)EQUIPMENT GROUNDING CONDUCTORS WILL BE SIZED IN ACCORDANCE WITH NEC TABLE 250.122. 13)CONDUCTOR TERMINATIONS WILL BE TORQUED PER DEVICE LISTING,OR MANUFACTURER'S RECOMMENDATIONS. 14)A PV AGGREGATION PANEL(SUB PANEL)WILL NOT BE INCLUDED FOR SYSTEMS WITH ONE BRANCH CIRCUIT. 15)A DEDICATED 120V BRANCH CIRCUIT IS REQUIRED IN MASTER.CLOSET(OR EQUIVALENT)FOR ENPHASE ENVOY MONITOR. SIGNAGE- 16)PV SYSTEMS SHALL BE CLEARLY MARKED IN ACCORDANCE WITH NEC ARTICLE 690 AND OTHER APPLICABLE STATE AND LOCAL CODES. 17)ALL SAFETY MARKING/PLACARDS SHALL BE PERMANENTLY ATTACHED BY ADHESIVE OR OTHER MECHANICAL MEANS. 18)MARKING/PLACARDS WILL BE METAL OR PLASTIC WITH ENGRAVED OR MACHINE PRINTED LETTERING. BACKGROUND WILL BE RED WITH WHITE CAPITAL LETTERING OF MINIMUM HEIGHT t. 19)ALL WIRING/RACEWAYS/JUNCTION BOXES WILL BE MARKED'PHOTOVOLTAIC POWER SOURCE:OR EQUIVALENT:WIRING/RACEWAYS SHALL BE MARKED EVERY 10'. BUILDER ELECTRICAL AND SOLAR CONTRACTORS- 20)INSTALLATION SHALL BE COMPLETED IN A NEAT AND WORKMAN-LIKE MANNER. 21)SPACE REQUIREMENTS FOR ALL ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110.26. LENNAR: ORIGINAL BY: DESIREE WILLIAMS DATE:16.4.14 CAMELLIA AT 980 MONTECITO DRIVE.#302 REVIEWED BY: SHAM MARUNA DATE:16.4.14 THE LAKES CORONA,CA 92879 REV.# BY DATE DESCRIPTION tmmasbd DWG TITLE: PAGE#: I SCALE: SITE LOCATION: 4571 Broadway Street INDIVIDUAL 29705 ARGYLE CIRCLE Boulder.CO 80304 PLOT PLAN 3 NITS MENIFEE,CA 303.447.030Q NOTES CAUTION: POWER TO THIS BUILDING IS SUPPLIED BY THE UTILITY AND A SOLAR PV SYSTEM. DISCONNECTS ARE LOCATED AS SHOWN. DATE or an ity of on the SOLADECK WIRE TRANSITION BOX (UNDER ARRAY) PV AC DISCONNECT EXTERIOR-GARAGE UTILITY METER 8 MAIN SERVICE PANEL (VERIFIED BY BUILDER) SERVICE BY QUALIFIED PERSONNEL ONLY CONTACT: SUNSTREET ENERGY GROUP 1-877-SLR-POWR PV POWER SOURCE — AC SPECS AC OPERATING VOLTAGE: 240 V AC OPERATING CURRENT: 9.9 A NOTE: SEE MASTER SET FOR ADDITIONAL PLACARD INFORMATION ORIGINAL BY: DESIREE WILLIAMS DATE:16.4.1E CAMELLIA AT LENMAR: 980 MONTELITD DRIVE,#302 REVIEWED BY:SHAUN MARUNA DATE:16.4.14 THE LAKES CORONA.CA 92879 REV.# BY DATE DESCRIPTION Vniamost(3 SOLAR DWG TITLE: PAGE#: SCALE: SITE LOCATION: 4571 Bmdwey Slreel INDIVIDUAL 29705 ARGYLE CIRCLE BoWder,CO SON PLOT PLAN 4 NTS MENIFEE,CA 303.447.0300 PLACARDS