Loading...
PMT16-01947 City of Menifee Permit No.: PMT16-01947 29714 HAUN RD. S/�CCELA� MENIFEE,CA 92586 Type: Residential Electrical MENIFEE Date Issued: 0 712 212 01 6 PERMIT Site Address: 29715 ARGYLE CIR,MENIFEE,CA 92584 Parcel Number: 364-360-030 Construction Cost: $7,650.40 Existing Use: Proposed Use: Description of SOLAR TR 3D422-3 CAMELLIA Work: 11 MODULES 2.92KW LOT 121 Owner Contractor LENNAR HOMES OF CA LENNAR HOMES OF CALIFORNIA INC 980 MONTECITO DR#302 25 ENTERPRISE CORONA,CA 92879 ALISO VIEJO,CA 92656 Applicant Phone:9493498269 JEREMIAH ACAYTURRI License Number.728102 LENNAR HOMES OF CALIFORNIA INC 25 ENTERPRISE ALISO VIEJO,CA 92656 Fee Description Oty Amount(S) Solar,Residential or Small Commercial 1 252.00 Building Permit Issuance 1 27.00 GREEN FEE 1 1.00 SMIP RESIDENTIAL 1 1.00 General Plan Maintenance Fee-Electrical 1 12.60 $293.60 The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and specifications or from preventing builiding operations being cared on thereunder when in violation of the Building Code or of any other ordinance of City of Menifee.Except as otherwise stated,a permit for construction under which no work is commenced within six months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be forfeited. AA_Bldg_Permit_Template.rpt Page 1 of 1 SAFETYBUILDING & • + APPLICATION "'Menifee DATE 0 6/1 512 01 6 PERMIT/PLAN CHECK NUMBER TYPE: ❑COMMERCIAL ❑✓ RESIDENTIAL [-]MULTI-FAMILY ❑MOBILEHOME ❑POOL/SPA []SIGN SUBTYPE: ❑✓ ADDITION []ALTERATION [-]DEMOLITION [:]ELECTRICAL ❑MECHANICAL ❑NEW ❑PLUMBING ❑RE-ROOF-NUMBER OF SQUARES DESCRIPTION OF WORK Solar Permit-Plan 2399-2.92 kW/11 PCs Master Solar Permit: PMT14-02630 PROJECT ADDRESS 29715 Argyle Circle., Menifee, CA 925844 ASSESSOR'S PARCEL NUMBER 369- 36n 0 0 LOT 121 TRACT 30422-3 PROPERTY OWNER'S NAME Lennar Homes of California, Inc. ADDRESS 980 MontecitO Dr.,Suite 302, Corona,CA 92879 PHONE (951)817-3680 EMAIL jeremiah.acayturri@lennar.com APPLICANT NAME Lennar Homes of California, Inc. ADDRESS 980 Montecito Dr.,Suite 302,Corona, CA 92879 PHONE (951)817-3680 EMAIL jeremiah.acayturri@lennar.com CONTRACTOR'S NAME Lennar Homes of California, Inc. OWNER BUILDER? ❑✓ YES❑NO BUSINESS NAME Lennar Homes of California, Inc. ADDRESS 980 Montecito Dr., Suite 302, Corona,CA 92879 PHONE (951)817-3680 EMAIL Jeremiah.acayturri@lennar.com CONTRACTOR'S STATE LIC NUMBER 728102 LICENSE CLASSIFICATION A&B VALUATION$ $7,650.40 SQ FT L SO FT APPLICANT'S SIGNATURE DATE 06/15/2016 CITYSTAFF USE ONLY w DEPARTMENT DISTRIBUTION CITY OF MENIFEE BUSINESS LICENSE NUMBER BUILDING PLANNING ENGINEERING FIRE I GREEN i SMIP INVOICE AMOUNT •/n PAID AMOUNT - 1 w 0CASH OCHECK it OCREDITCARD VISA/MC PLAN CHECK FEES PAID AMOUNT 0 CASH 0 CHECK# O CREDITCARD VISA/MC OWNER BUILDER VERIFIED OYES O NO DI-NUMBER NOTARIZED LETTER O YES O NO City of Menifee Building&Safety Department 29714 Haun Rd. Menifee, CA 92586 951-672-6777 www.cityofinenifee.us Inspection Request Line 951-246-6213 SYSTEM INFORMATION BUYER ACKNOWLEDGES THAT THE SOLAR MODULES TO BE INSTALLED ITEM OTY MFR. MODEL ON THE ROOF OF THE HOME WILL BE SUBSTANTIALLY IN THE SYSTEM SIZE 2.92XW 1 LOCATIONS INDICATED BY THE ILLUSTRATION. MODULE II PCS.j HYUNDAI I HIS-S265RG(265W) BUYER: INVERTER It PCS. ENPHASE 1 11215-60-2LL-S22-IG ROOF TYPE TILE W/COMPOSITE SHINGLE UNDER ARRAY DATE: SUB-ARRAIY INFOR ARR YM#1IO ARRAY#2 ARRAY#3 City of Menife ITY OF ME14IFE MOD OTY II NA NA Building Dep BUYER: TILT 23° NA. I] NA' IIJUiLU AND : AZIMUTH 89- NA- NA- DATE: JUN 2 3 Z016 PtAN APPROM Received REVIEWED E Y *Approval of these pl ins s�ha approval of,any viola ion of) regulations and ordin nces. jobsite until completi n. 29'-8'ARRAY 30'-6'FLASHING T-9- I I I - I I I 1 i SOLADECK WIRE TRANSITION BOX (UNDER ARRAY) � � I I I PV AC DISCONNECT EXTERIOR-GARAGE I' UTILITY METER a MAIN SERVICE PANEL T' (VERIFIED BY BUILDER) I —— J 9 NOTE:DIMENSIONS ARE SHOWN IN PLANE OF ROOF Z PLAN 2399 ELEVATION A ORIENTATION 2 LO #121 CAMELLIA AT LENNAR: ORIGINAL BY: DESIREE WILLIAMS DATE:16:4.I 16. 980 MONTECITO DRIVE.#302 REVIEWED BY:SHAUN MARUNA DATE: 4.I4 THE LAKES CORONA.CA 92879 REV.# BY DATE I DESCRIPTION 4.2 namasb6 DWG TITLE: PAGE#: SCALE: Boise SITE LOCATION: i 4571 Broadway Street INDIVIDUAL 29715 ARGYLE CIRCLE Hodder,CO 803D4 PLOT PLAN 1 1/16'=I'-0' MENIFEE.CA 303.447.0300 SYSTEM LAYOUT MODULE SPECS AND CALCULATIONS INVERTER SPECS AND CALCULATIONS ITEM NOTE/CALC UNIT DETAIL ITEM NOTE/CALC UNIT DETAIL LOCATION MENIFEE.CA INV. MAKE INVERTER SPEC ENPHASE TEMP,AMBIENT HIGH(TMAX) ASHRAE 2% °C 37 INV. MODEL INVERTER SPEC M215-60-2LL-S22-IG TEMP.AMBIENT LOW(THIN) ASHRAE EXTR.MIN °C -2 INV. MAX POWER,(VAC MAX) INVERTER SPEC WATTS(AC) 225 TEMP.MODULE TEST(TTEST) MODULE SPEC °C 25 INV. INPUT V.(VDC MAX) INVERTER SPEC VOLTS OKI 48 TEMP,DELTA LOW(TOELTA) THIN-TTEST °C -27 INV. OUTPUT V.(Vac NOM) INVERTER SPEC VOLTS(AC) 240 MOD.MANUFACTURER MODULE SPEC HYUNDAI INV. OUTPUT FREQUENCY INVERTER SPEC HERTZ 60 MOD.PART NUMBER MODULE SPEC HIS-S265RG INV.OUTPUT CURRENT.IAC INVERTER SPEC AMPS(AC) 0.9 MOD.POWER STC(P) MODULE SPEC WATTS(OW 265 INV.PHASE QUANTITY INVERTER SPEC PHASE 1 DEF MOD.POWER PTC MODULE SPEC WATTS(CC) 238 COMPLIANCE INVERTER SPEC ULI741/IEEEI MOD.OPERATING VOLTAGE(VMP) MODULE SPEC VOLTS 00 31.30 INV. GROUNDING INVERTER SPEC ISOLATED MOD.OPEN CCT.VOLTAGE(VOO MODULE SPEC VOLTS 00 38.10 INV.OTY.MAX/BRANCH CCT. 1 INV.QI OTY 11 MOD.COEFF. VOLT/TEMP(COEF) MODULE SPEC V/°C -0.114 BRANCH CCT.OUTPUT.IMAXBG I(IAC'INV.GTY8e) I AMPS(AC) 9.90 MOD.MAX VOLTAGE 0MAX1w0) (VOC+(TO•COEF)) VOLTS(CC) 41.18 INV.QUANTITY,TOTAL I INV.OTYi I OTY I II MOD.OPERATING CURRENT(IMP) MODULE SPEC AMPS(Oe) 8.50 TOTAL SYSTEM OUTPUT,IMAXTS (IAC-INV.QTYT) I AMPS(AC) 19.90 MOD.SHORT CCT.CURRENT(Ise) MODULE SPEC AMPS(Oc) 9.00 MOD.MAXIMUM CURRENT(TMAX) (ISC• 1.25) AMPS(DO 11.25 MIN.AMPACITY REQ'D,PER NEC OMAX•1.25) AMPS 00 14.06 SERIES FUSE RATING,MAX MODULE SPEC AMPS(CC) 15 ELECTRICAL EQUIPMENT SCHEDULE KEY OTY MANUFACTURER MODEL NOTES TRADE �e construed t 1 II HYUNDAI HIS-S265RG(265W) PV MODULE SOLAR 2 II ENPHASE M215-60-2LL-S22-IG PVINVERTER SOLAR rovisiol isofthe 3 1 RSTC/SOLADECK 07B6-3R5 PV ROOF JUNCTION BOX,NEMA 3R SOLAR 4 1 CUTLER-HAMMER DG221URB PV AC DISCONNECT,NEMA 3R,240V.30A SOLAR it of al 1proved 5 1 ENPHASE ENVOY PV DATA MONITOR,120V SOLAR 6 1 TBD TBD 120V DEDICATED RECEPTACLE FOR ENVOY PV DATA MONITOR SOLAR 7 1 TBD TBD CATS PORT FOR SOLAR PV INTERNET CONNECTION TO HOME NETWORK BOX SOLAR 8 NOTE CUTLER-HAMMER TBD PV BRANCH CIRCUIT BREAKERS: I x 15A-IP(ENVOY) SOLAR 9 NOTE CUTLER-HAMMER TBD PV BREAKER,I x 20A-2P.LOCATE AT OPPOSITE END OF BUS FROM MAIN BREAKER SOLAR 10 I TBD TBD SERVICE PANEL,MIN. 125A BUS BLDR.ELEC. II I TBD TBD UTILITY METER.IPH.120/240V,200A BLDR.ELEC. 12 I TBD TBD GROUNDING ELECTRODE UFER BLDR.ELEC. CONDUCTOR SIZING CALCULATIONS INTERCONNECTION CALCULATIONS U CONDITION OF USE(COLD: (AMPACITY•TEMP.DEBATE•FILL DEBATE)Vs.REO'D(IMAX) ITEM UNIT PANEL 2)TERMINALS(TERM): AMPACITY AT TERMINALS. Va.REG'D.(IMAX• 1.25) PANEL MFR. CUTLER-HAMMER KEV SIZE CU/AL INSULATION CALC. AMPACITY W/O TEMP. FILL RESULT REO'D OCD BUS RATING AMPS 200 TYPE DERATES DERATE DERATE (AD (A) USED(A) MAIN DISCONNECT AMPS 200 A #12 CU THWN-2 COU 30 0.76 1.0 22.80 9.90 ALLOWED PV PER NEC AMPS 40 TERM 25 25 12.38 20 PV OCPD DEVICE USED AMPS 20 B #10 CU NM-B COU 40 0.91 1.0 36.40 9.90 TERM 35 35 12.38 20 C #10 CU NM-B COU 40 0.91 1.0 36.40 9.90 TERM 35 35 12.38 20 CONDUCTOR SCHEDULE KEY CONDUCTORS CU/AL PE TY LOCATION TRADE A I-#12 ENGAGE CABLE.1-#6G,FREE AIR CU TC-ER ARRAY SOLAR B I 3-#10,1-#10 EGC I CU NM-B(ROMEX) INTERIOR SOLAR C 1 3-#10.1410 EGC CU I NM-B(ROMEX) INTERIOR I SOLAR 0 I CAT5E,ETHERNET CABLE CU I CAT5E INTERIOR I SOLAR 5 © II 7 - o IS- SEE NOTE 15 10 qO - -. zoON 0 N 4� 1 A B I C = 12 I ROOF EXTERIOR-GARAGE ELECTRICAL DIAGRAM 2.92 KW LOT#121 ORIGINAL BY: DESIREE WILLIAMS DATE:16.4.14 CAMELLIA AT LENNAR: 980 MNNTECI7 DRIVE.#302 REVIEWED BY:SHAUN MARUNA I DATE:16.4.14 THE LAKES CORONA.CA 92879 REV.# BY DATE DESCRIPTION •, namaste DWG TITLE: PAGE#: SCALE: SITE LOCATION: INDIVIDUAL 457T der.0 8Steel PLOT PLAN 2 NTS MENI ARGYLE CIRCLE BO301 CO 8080E ELECTRICAL MENIFEE.CA 303.44T.0300 STRUCTURAL NOTES: SOLAR CONTRACTOR- D ALL PV ROOF ATTACHMENTS WILL BE SPACED ALONG MODULE RACKING RAILS AT NOT GREATER THAN 48.O.C. 2)ALL PV ROOF ATTACHMENTS WILL BE STAGGERED BY ROW AMONGST THE ROOF FRAMING MEMBERS,TO MAXIMUM EXTENT POSSIBLE. 3)ROOF PENETRATIONS ASSOCIATED WITH SOLAR RACKING WILL BE SEALED WITH AN APPROVED SEALANT. 4)SOLADELK WIRE TRANSITION BOX WILL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS. IT WILL BE FLASHED AND SEALED. 5)PV ARRAY WILL BE A MINIMUM OF 3'ABOVE THE COMPOSITE SHINGLE ROOF SURFACE. 6)THE UNIRAC SOLARMOUNT RACKING SYSTEM AND SOLAR PV ARRAY WILL BE INSTALLED ACCORDING TO THE UNIRAC SOLARMOUNT CODE-COMPLIANT INSTALLATION MANUAL,VERSION 227.3.PUB 140113-ICC,JANUARY 2014. 7)UNIRAC TOP CLAMPS REQUIRE A ONE INCH(I-)SPACE BETWEEN PV MODULES.SOLARMOUNT RAILS MUST EXTEND A MINIMUM OF TWO INCHES(2')BEYOND THE EDGE �T ENT OF THE PV ARRAY/SUB-ARRAY. 1 8)UNIRAC SOLARMOUNT REQUIRES THAT A THERMAL EXPANSION GAP BE INSTALLED FOR ANY RAIL LENGTH OF GREATER THAN 40'. ROOFING CONTRACTOR- 1)DISTANCE BETWEEN ARRAY EDGE AND TRANSITION FLASHING(COMPOSITION TO TILE)WILL BE A MINIMUM OF 3-, 2)26 GAUGE INTERLOCKING FLASHING'SIDEWALL-TO BE INSTALLED ALONG THE LENGTH OF THE PV ARRAY AT ROOFING MATERIAL TRANSITION. IT SHALL BE APROVED PRIOR TO PV SYSTEM INSTALLATION. 3)PEEL-N-STICK BASE TO BE INSTALLED ONE FOOT 01 OR MORE BEYOND THE EDGE OF THE COMPOSITION SHINGLE,DOWN TO THE ROOF EAVE.PEEL-N-STICK BASE TO BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS. WW 4)AREAS UNDER EACH PV ARRAY SHALL BE ROOFED WITH COMPOSITION SHINGLE. COMPOSITION SHINGLE SHALL RUN FROM ABOVE THE PV ARRAY TO THE ROOF EAVE. 5)TILE INSTALLED BELOW THE ARRAY TO BE INSTALLED ABOVE THE COMPOSITION ROOF PER ROOFER SPECIFICATIONS. 6)BIRDSTOP WILL BE INSTALLED AT THE UPPERMOST TRANSITION FROM TILE TO COMPOSITION SHINGLE. BIROSTOP TO BE SPECIFIED BY ROOFER PRIOR TO INSTALLATION. a pE unit for,l oral,stateorc is mi ist be ker ELECTRICAL NOTES: GENERAL- U ALL PV EQUIPMENT WILL BE TESTED AND LISTED FOR ITS USE BY A NATIONALLY RECOGNIZED TESTING LABORATORY(NRTL). 2)THE GROUNDING OF THE PHOTOVOLTAIC SYSTEM SHALL COMPLY WITH THE APPLICABLE VERSION OF THE NEC/CEC. 3)ALL GROUNDING ELECTRODE CONDUCTORS WILL BE INSTALLED IN A CONTINUOUS LENGTH EXCEPT WHERE SPLICED BY AN IRREVERSIBLE CONNECTOR OR EXOTHERMIC WELD. 4)NON-CURRENT CARRYING METAL PARTS SHALL BE CHECKED FOR PROPER GROUNDING,NOTING THAT TERMINAL LUGS BOLTED ON AN ENCLOSURE'S FINISHED SURFACE MAY BE ELECTRICALLY INSULATED BECAUSE OF PAINT/FINISH. PAINT/FINISH AT POINT OF CONTACT SHALL BE PROPERLY REMOVED. 5)ROOF PENETRATIONS WILL BE COMPLETED AND SEALED PER APPLICABLE CODE. 61 ALL CONDUCTORS WILL HAVE A 90aC RATING TO ENSURE CODE COMPLIANCE. SOLAR CONTRACTOR- 7)MODULE CERTIFICATIONS WILL INCLUDE UL1703,IEC61646.IEC61730. 8)CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS. 9)RACEWAY POINT OF PENETRATION FROM EXTERIOR TO INTERIOR WILL BE SEALED TO PREVENT INGRESS OF WATER AND INSECTS. 10)DC WIRING IS LIMITED TO PV ARRAY FOOTPRINT W/ENPHASE MICRO-INVERTER SYSTEM. 11)MODULE AND ENPHASE WIRING SHALL BE LOCATED AND SECURED UNDER THE ARRAY USING SUITABLE WIRING CLIPS.WIRING SHALL NOT MAKE CONTACT WITH THE ROOF SURFACE AND SHALL BE MANAGED IN A WORKMAN-LIKE MANNER. 12)EQUIPMENT GROUNDING CONDUCTORS WILL BE SIZED IN ACCORDANCE WITH NEC TABLE 250.122. 13)CONDUCTOR TERMINATIONS WILL BE TORQUED PER DEVICE LISTING,OR MANUFACTURER'S RECOMMENDATIONS. 14)A PV AGGREGATION PANEL(SUB PANEL)WILL NOT BE INCLUDED FOR SYSTEMS WITH ONE BRANCH CIRCUIT. 15)A DEDICATED 120V BRANCH CIRCUIT IS REQUIRED IN MASTER CLOSET(OR EQUIVALENT)FOR ENPHASE ENVOY MONITOR. SIGNAGE- 16)PV SYSTEMS SHALL BE CLEARLY MARKED IN ACCORDANCE WITH NEC ARTICLE 690 AND OTHER APPLICABLE STATE AND LOCAL CODES. 17)ALL SAFETY MARKING /PLACARDS SHALL BE PERMANENTLY ATTACHED BY ADHESIVE OR OTHER MECHANICAL MEANS. III)MARKING/PLACARDS WILL BE METAL OR PLASTIC WITH ENGRAVED OR MACHINE PRINTED LETTERING.BACKGROUND WILL BE RED WITH WHITE CAPITAL LETTERING OF MINIMUM HEIGHT k 19)ALL WIRING/RACEWAYS/JUNCTION BOXES WILL BE MARKED*PHOTOVOLTAIC POWER SOURCE:OR EQUIVALENT;WIRING/RACEWAYS SHALL BE MARKED EVERY 10'. BUILDER ELECTRICAL AND SOLAR CONTRACTORS- 20)INSTALLATION SHALL BE COMPLETED IN A NEAT AND WORKMAN-LIKE MANNER. 21)SPACE REQUIREMENTS FOR ALL ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110.26. LENNAR: ORIGINAL BY: DESIREE WILLIAMS DATE:I6.L.IL CAMELLIA AT REVIEWED BY: SHAUNMARLNA DATE:16.4.14 THE LAKES CO NA.CA I92 DRIVE.#302 CORONA.GA 92879 REV.# BY DATE DESCRIPTION namI SOLA! DWG TITLE: PAGE*; I SCALE: SITE LOCATION: INDIVIDUAL 4671 BouldBroer, CO 8 Street PLOT PLAN 3 NITS MENI ARGYLE CIRCLE Ba30er,C080304 NOTES MENIFEE,CA 303.447.0300 CAUTION: POWER TO THIS BUILDING IS SUPPLIED BY THE UTILITY AND A SOLAR PV SYSTEM. DISCONNECTS ARE LOCATED AS SHOWN. UE 1 the SOLADECK WIRE TRANSITION BOX (UNDER ARRAY) PV AC DISCONNECT EXTERIOR-GARAGE UTILITY METER 8 MAIN SERVICE PANEL (VERIFIED BY BUILDER) SERVICE BY QUALIFIED PERSONNEL ONLY CONTACT: SUNSTREET ENERGY GROUP I-877-SLR-POWR PV POWER SOURCE - AC SPECS AC OPERATING VOLTAGE: 240 V AC OPERATING CURRENT: 9.9 A NOTE: SEE MASTER SET FOR ADDITIONAL PLACARD INFORMATION ORIGINAL BY: DESIREE WILLIAMS I DATE:16.4.14 CAMELLIA AT LENNAR: 980 MONTECITO DRIVE,#302 REVIEWED BY:SHAUN MARUNA I DATE:16.4.14 THE LAKES CORONA,CA 92879 REV.# BY DATE DESCRIPTION namasCe Soul DWG TITLE: PAGE#: SCALE: SITE LOCATION: 4Bo BroacWay CO8Street INDIVIDUAL MENI ARGYLE CIRCLE Boulder,C0803D4 PLOT PLAN 4 NTS MENIFEE.CA PLACARDS 303.447.0000