Loading...
PMT16-01927 City of Menifee Permit No.: PMT16-01927 29714 HAUN RD. Type: Residential Electrical 4l;kCCEL/? MENIFEE, CA92586 "'1113�1— MENIFEE Date Issued: 06/29/2016 PERMIT Site Address: 29567 COOL MEADOW DR, MENIFEE, Parcel Number: 339-382-003 CA 92584 Construction Cost: $25,000.00 Existing Use: Proposed Use: Description of INSTALL ROOF MOUNTED SOLAR SYSTEM,32 PANELS, 1 INVERTER, 8.48 kW Work: Owner Contractor ANTHONY VILLA SUNCREST SOLAR INC 29567 COOL MEADOW DRIVE 420 E SOUTH TEMPLE SUITE 280 MENIFEE, CA 92584 SALT LAKE CITY, UT 84111 Applicant Phone:8019241100 JOSHUA PETERSON License Number:987868 SUNCREST SOLAR INC 420 E SOUTH TEMPLE SUITE 280 SALT LAKE CITY, CA 84111 Phone: 8003764115 Fee Description O_yt Amount($I Solar, Residential or Small Commercial 1 252.00 Building Permit Issuance 1 27.00 Additional Plan Review Electrical 158 157.50 GREEN FEE 1 1.00 SMIP RESIDENTIAL 1 4.00 General Plan Maintenance Fee-Electrical 1 12.60 $454.10 The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and specifications or from preventing builiding operations being carried on thereunder when in violation of the Building Code or of any other ordinance of City of Menifee.Except as otherwise stated,a permit for construction under which no work is commenced within six months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be forfeited. AA_Bldg Permit Template.rpt Page 1 of 1 CITY OF MENIFEE LICENSED DECLARATION property who builds or improves thereon,and who contracts for the projects I hereby affirm under penalty of perjury that 1 am under provisions of with a licensed contractor(s)pursuant to the Contractors State License Law). Chapter9(commencing with section 7000)of Division 3 of the Business and D I am exempt from licensure under the Contractor's State License Law for Professions Code and my license is in full force and effect. the following reason: License Class C�J 0 License No By my signature below I acknowledge that,except for my personal residence Expires/( /1 3fJ/7 Signature in which I must have resided for at least one year prior to completion of improvements covered by this permit.I cannot legally sell a structure that I WORKER'S COMPENSATION DECLARATION have built as an owner-builder if it has not been constructed in its entirety by o I hereby affirm under penalty of perjury one of the following declarations:I licensed contractors.I understand that a copy of the applicable law,Section have and will maintain a certificate of consent of self-insure for workers 7044 of the Business and Professions Code,is available upon request when compensation,issued by the Director of Industrial Relations as provided for this application is submitted or at the following website: by Section 3700 of the Labor Code,for the performance of work for which www,leainfo.ca.aov/calaw.html. this permit is issued. . Polley N Date ,Lyy"Lf,`J,I",ve and will maintain workers compensation insurance,as required by PROPERTY OWNER OR AUTHORIZED AGENT ,kection 3700 of the Labor Code,for the performance of the work for which o By my signature below I certify to each of the following:I am the property this permit is issued.My workers compensation insurance carrier and policy owner or authorized to act on the property owners behalf.I have read this number are:1 (j h` application and the information I have provided is correct I agree to comply Cartier Ir li '•y IJIt�M1.tbgpP SGN• with all applicable city and county ordinances and state laws relating to �/��—� building construction.I authorize representatives of this city or county to Policy 9 (ff ZM Expires /d Z A / (" enter the above identified property for inspection purposes. (This section need not to be completed is the permit is for one-hundred Date dollars($100)or less PROPERTY OWNER OR AUTHORIZED AGENT �.,. o I certify that in the performance of the work for which this permit is issued, O -g/�l� I shall not emolov any persons in any manner so as to become subject to the CITY BUSINESS LICENSE p / workers compensation laws of California,and agree that if I should become HAZARDOUS MATERIAL DECLARATION subject to the workers compensation provisions of Section 370D of the Labor Code,I shalhwRPITo ly with those provisions. Will the applicant or future building occupant handle hazardous material or a mixture containing a hazardous material equal to or greater that the Applicant Date G��q'//G amounts ps, pcTfipged on the Hazardous Materials Information Guide. WARNING:FAILURE TO SECURE WORKER'S COMPENSATION COVERAGE IS Dyes [t� UNLAWFUL,AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES Will the Intended use of the building by the applicant or future building AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS($300,000),IN occupant require a permit for the construction or modification from South ADDITION TO THE COST OF COMPENSATION,DAMAGES AS PROVIDED FOR Coast Air Qu lity Management District(SCAQMD)?See permitting checklist IN SECTION 3706 OF THE LABOR CODE,INTEREST,AND ATTORNEYS FEES forguideli s CONSTRUCTION LENDING AGENCY D Yes No I hereby affirm that under the penalty of perjurythere Is a construction Will the proposed building or modified facility be within 1000 feet of the lending agency for the performance of the work which this permit is issued outer bourydary of a school? (Section 3097 Civil Code) D Yes id No OWNER BUILDER DECLARATIONS I have read the Hazardous Material Information Guide and the SCAQMD permitting checklist.I understand my requirements under the State of I hereby affirm under penalty of perjury that 1 am exempt from the Contractors License Law for the reason(s)indicated below by the California Health e &Safety Cade,Section 25505 and 25534 concerning hazardous ri rtin . checkmark(s)I have placed next to the applicable Rem(s)(Section 7031.5 oyes o /� Business and Professions Code).Any city or county that requires a permit to Date `71G construct,alter,improve,demolish or repair any structure,prior to its PROPERTY OWNER OR AUTHORIZED AGENT issuance,also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractors State EPA RENOVATION,REPAIR AND PAINTING(RRP) License Law(Chapter9(commencing with Section 7000)of Division 3 of the The EPA Renovation,Repair and Painting(RRP)Rule requires contractors Business and Professions Code)or that he or she is exempt from licensure receiving compensation for most work that disturbs paint in a pre-1978 and the basis for the alleged exemption.Any violation of Section 7031.5 by residence or childcare facility to be RRP-certified firms and comply with an Applicant for a permit subjects the applicant to a civil penalty of not more required practices.This includes rental property owners and property than($500). managers who do the paint-disturbing work themselves or through their o I,as owner of the property,or my employee with wages as their sole employees.For more information about EPA's Renovation Program visit compensation,will do( )all of or( )portion of the work,and the structure is www.eua.aov/lead or contact the National Lead Information Center at not Intended or offered for sale.(Section 7044,Business and Professions 1-800-424-LEAD(5323). Code;The Contractors State License Law does not apply to an owner of a o An EPA Lead-Safe Certified Renovator will be responsible for this project property who,through employees'or personal effort,builds or improves the property provided that the improvements are not intended or offered for Certified Firm Name: sale.If,however,the building or improvement is sold within one year of Firm Certification No.: completion,the Owner-Builder will have the burden of proving that it was not built or improved for the purpose of sale. o No EPA Lead-Safe Certified Firm is required for this project because: a 1,as owner of the property am exclusively contracting with licensed contractors to construct the project(Section 7044,Business and Professions Code:The Contractors State License Law does not apply to an owner of a If your project does not comply with EPA RRP rule please fill out the RRP Acknowledgement. EsGil Corporation In(Partnership with Government for ouifding Safety DATE: 06/24/16 ❑ APPLICANT �!"JURIS. JURISDICTION: City of Menifee ❑ PLAN REVIEWER ❑ FILE PLAN CHECK NO.: PMT16-01927 SET: I PROJECT ADDRESS: 29567 Cool Meadow Dr. PROJECT NAME: ANTHONY A VILLA 7,600 Watts Solar Photovoltaic System ® The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. ❑ The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. ❑ The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. ❑ The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. ❑ The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. ❑ The applicant's copy of the check list has been sent to: ® Esgil Corporation staff did not advise the applicant that the plan check has been completed. ❑ Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted— Telephone #: Date contacted: --- (bb Fax #: Mail Telephone Fax In Person E-mail: ❑ REMARKS: By: Sergio Azuela Enclosures: EsGil Corporation ❑ GA ❑ EJ ❑ PC 06/22 9320 Chesapeake Drive, Suite 208 ♦ San Diego,California 92123 ♦ (858)560-1468 ♦ Fax(858)560-1576 City of Menifee PMT16-01927 06/24/16 ADO NOT PAY— THIS IS NOT AN INVOICE] VALUATION AND PLAN CHECK FEE JURISDICTION: City of Menifee PLAN CHECK NO.: PMT16-01927 PREPARED BY: Sergio Azuela DATE: 06/24/16 BUILDING ADDRESS: 29567 Cool Meadow Dr. BUILDING OCCUPANCY: TYPE OF CONSTRUCTION: BUILDING AREA Valuation Reg. VALUE ($) PORTION ( Sq. Ft.) Multiplier Mod. Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code mnf Manuallnput Bldg, Permit Fee by Ordinance W Plan Check Fee by Ordinance W Type of Review: ❑ Complete Review ❑ Structural Only ❑❑Repetitive Fee Other T Repeats Hourly1.5 Hrs. @ / EsGil Fee $1D5.00 $157.50 ✓ ' Based on hourly rate Comments: 1 1/2 hours plan review. Sheet 1 of 1 macvalue.doc+ n UTAH OFFICES VECTOR Lam nY N e n r. I n E E R S St. George Project Number: U1621-1633-161 June 20,2016 V Suncrest Solar 420 E South Temple,Suite 280 ' Salt Lake City,UT 84111 ATTENTION: John Corliss REFERENCE: Anthony A Villa Residence:29567 Cool Meadow Drive,Menifee,CA 92584 Solar Panel Installation Dear Mr.Corliss: P- Per your request, we have reviewed the attached documents and photos relating to the installation of solar panels at the above-referenced site. The following materials and components are proposed in the installation of the solar panels. Roof structure:2x4 Manufactured Roof Trusses @ 24"O.C. Roof material:Concrete tile Mounting connections:(2)5/16"x 3-1/2"lag screws Based upon our review, it is our conclusion that the installation of solar panels on this existing roof per the attached documents and in accordance with Suncrest Solaes installation requirements will not adversely affect the structure of this house. The design of supporting members is by the manufacturer and/or installer. The adopted building code in this jurisdiction is the 2013 edition of the California Building Code which references ASCE 7-10. The solar panels and attachments have been designed to withstand the parameters listed below: Design wind speed for risk category 11 structures: 110 mph(3-sec gust) Wind exposure:Category C Our conclusion regarding the adequacy of the existing roof is based on the fact that the additional weight of the solar panels is 3 pounds per square foot or less. In the area of the solar panels,the total additional load is less than 5%of the original load per the attached calculations. In the area of the solar panels, other live loads will not be present or greatly reduced. Regarding snow loads (if any), it is our conclusion that since the panels are slippery and dark, effective snow loads will likely be reduced in the areas of the panels. The attached calculations verify the capacity of the connections against wind,the governing load case.Regarding seismic loads,we conclude that any additional forces will be small. With an assumed roof dead load of 24 psf, solar panel dead load of 3 psf, and affected roof area of 40%(maximum),the additional dead load (and consequential seismic load) will be 5.0%. This calculation conservatively neglects the weight of wall dead load. Because the increase is less than 10%, this alteration meets the requirements of the exception in Section 3404.4 of the 2013 edition of the California Building Code. Thus the existing structure is permitted to remain unaltered. Installation of the solar panels must be performed in accordance with Suncrest Solar's installation requirements. Particular attention must be paid to the maximum allowable spacing of attachments and the location of solar panels relative to roof edges. The use of solar panel support span tables provided by others is allowed only where the building type, site conditions, site-specific design parameters,and solar panel configuration match the description of the span tables. Attachments to existing roof joist or rafters must be staggered so as not to overload any existing structural member. Electrical engineering is beyond our scope. Waterproofing around the roof penetrations is the responsibility of others. All work performed must be in accordance with accepted industry-wide methods and applicable safety standards. Vector Structural Engineering assumes no responsibility for improper installation of the solar panels. Please note a representative of Vector Structural Engineering has not physically observed the roof framing. Our conclusions are based upon the assumption that all structural roof components and other supporting elements are in good condition, free of damage and deterioration, and are sized and spaced such that they can resist standard roof loads. � Very truly yours, �9 QgOFFSS/p N, n, VECTOR STRUCTURAL ENGINEERING,LLC 5 , 7 s� C I V IN, `N� Russell N.Emery,P.E. 9T� OF CALXF / Senior Engineer 06/20/2016 9138 S. State St., Suite 101 I Sandy, UT 84070/T (801) 990-1775/F (801) 990-1776 /www.vectorse.com Page 2 of 29 JOB NO.:U1621-1633-161 DESIGNED: AJM E C TO R DATE: 06/20/16 E n O 1 11 E E R 8 PROJECT: Anthony A Villa Residence SUBJECT: PV Panel Calculations Com onents and Cladding Wind Calculations Label: Solar Panel Array Note: Calculations per ASCE 7-10 SITE-SPECIFIC WIND PARAMETERS: Basic Wind Speed[mph]: 110 Notes: Exposure Category: C Used the following effective areas: Importance Factor, I: 1.00 Zone 1: 12 Zone 2: 12 Zone 3: 12 ADDITIONAL INPUT&CALCULATIONS: Height of roof, h [ft]: 25 (Approximate) Camp/Cladding Location: Gable/Hip Roofs 70 5 0 5 270 Enclosure Classification: Enclosed Buildings Zone 1 GCP: 0.9 Figure 30.4-2B (enter largest abs. value) Zone 2 GCP: 1.7 (enter largest abs. value) Zone 3 GCP: 2.6 (enter largest abs. value) a: 9.5 Table 26.9-1 ZB[ft]: 900 Table 26.9-1 Kh: 0.945 Table 30.3-1 KI: Figure 26.8-1 (leave blank for negligible topographic effects) K2: Figure 26.8-1 (leave blank for negligible topographic effects) K3: Figure 26.8-1 (leave blank for negligible topographic effects) Kai: 1 Equation 26.8-1 Kd: 0.85 Table 26.6-1 Velocity Pressure, qh[psf]: 24.89 Equation 30.3-1 GCP;: 0.18 Table 26.11-1 (largest abs.value) OUTPUT: P=qh GCS — GC,,, Zone 1 Pressure, p [psf]: 26.88 psf(1.OW, Interior Zones*) Zone 2 Pressure, p[psf]: 46.79 psf(1.OW, End Zones*) Zone 3 Pressure, p[psf]: 69.19 psf(1.OW, Corner Zones*within a) (*a=assumed=3') Page 3 of 29 E C T® R JOB N U 633-161 DESIGNED: AJM DATE:E: 06/20/1/20/16 E n S I n E E R S PROJECT: ANTHONY A VILLA RESIDENCE SUBJECT: GRAVITY LOADS CALCULATE ESTIMATED GRAVITY LOADS Increase due to Original ROOF pitch loading ROOF PITCH/12 5 CONCRETE TILE 13.88 1.08 12.81 psf 1/2" PLYWOOD 1.63 1.08 1.50 psf FRAMING 3.00 psf INSULATION 2.00 psf 1/2" GYPSUM CLG. 2.20 psf M, E & MISC 1.30 psf OTHER 0.00 psf DL 24.00 psf SOLAR DL 3.00 psf LL 20.00 psf Page 4 of 29 JOB NO.: U1621-1633-161 DESIGNED: AJM \/PE C TO R DATE: 6/20/2016 E n O I n E E R S PROJECT: ANTHONY A VILLA RESIDENCE SUBJECT: LOAD COMPARISON Label: Solar Panel (Unit Area) Loads: Wind Load.W: p= 16.1 psf (0.6W from wind talcs) Zone 1 Height, h: 1.0 ft Max. Horiz. Dim.: 1..0 ft Vtmns: 16.128 lb Wind Controls Seismic Load, E: Consider Seismic: Yes Occupancy Category: II Fa= 1.0 Seismic Design Category: D F = 1.5 IP= 1.00 SMS= 1.5 Site Class: D SMi = 0.9 RP= 2.5 Sos= 1.0 Ss= 1.500 SD1 = 0.6 S, = 1 0.600 ap= 2.5 0.7*Fp,min= 1 0.630 jib z= 1.0 ft 0.7*FP.M.= 1 3.360 lb h= 1.0 ft z/h= 1.0 0.7*Fp."ns= 2.520 jib 0.7*Fp,ion9= 2.520 lb 0.7*Fp ved= 0.420 Ib Page 5 of 29 YECTOR JOB NO.: U1621-1633-161 DESIGNED: AJM DATE: 06/20/16 PROJECT: ANTHONY A VILLA RESIDENCE SUBJECT: CONNECTION CAPACITY Lag Screw Connection Capacity: Demand: Lag Screw Size: 5/16 Pressure Max Cd: 1.6 (0.6 Wind) Spacing* Max.Trib. Max. Uplift Embedment: 2.5 in (psf) (ft) Area (W) Force Capacity: 205 Ibs/in.emb. Zone 1: 16.1 4 12 194 Number of Screws: 2 Zone 2: 28.1 4 12 337 Total Capacity: 1640 Ibs Zone 3: 41.5 4 12 498 Demand<Capacity: CONNECTION OKAY *Max.Spacing per Suncrest Drawings Page 6 of 29 ECTOR JOB NO.: U1621-1633-161 DESIGNED: AJM DATE: 06/20/16 PROJECT: ANTHONY A VILLA RESIDENCE SUBJECT: CAPACITY OF EXISTING CHECK EXISTING ROOF TRUSS/RAFTER Existing Truss/Rafter Parameters Span: 22.0 ft(Approximate) Trib Width for Existing: 2 ft Line Loads: Solar Panel Location: DL: 24 psf 48 plf a,ft: 0.5 (Approximate) Lr': 20 psf 40 plf b,ft: 11.0 (Approximate) Solar thforS Solar: ft 12 plf Trib Width for Solar: 4 ft 'Lr reduced to 15 psf in location of panels as live loads will be highly reduced or nonexistent in location of panels. Existing Load Reactions/Moments(DL+Lr) Reaction, Pori: 968.055 Ibs Moment, Mori: 5324.303 lb-ft Load ReactionslMoments including Ds Reaction, Pnew: 984 Ibs Moment, MneW: 5385 lb-ft Ratio of Original Reactions/Moments to New Pnm/Pore 101.60% <105% Existing is okay Mnew/Morr: 101.13% <105% Existing is okay PER SECTION 3403.3 of 2013 CBC, EXISTING ROOF TRUSSES/RAFTERS ARE OKAY TO REMAIN UNALTERED b a Ds DL+Lr+W All, W SPAN Page 7 of 29 E C T O R JOB NO.: U16211633-161 DESIGNED: AJM DATE: 06l20/16 E n G 1 n E E R S PROJECT: ANTHONY A VILLA RESIDENCE SUBJECT: LATERAL SYSTEM CHECK CHECK MAIN LATERAL RESISTING SYSTEMS SEISMIC: Estimated Roof Dead Load 24.00 psf Max.%of Roof w/Panels 40 % Dead Load from Panels 3 psf Total Dead Load 25.2 psf(Roof DL+%of roof w/Panels* Panel DL) Increase in Dead Load 5.0% Conservatively neglecting the weight of exisisting wall materials,the installation of the solar panels represents in increase in the the total weight(and resulting seismic load)of 5%. Because the increase is less than 10%,this alteration meets the requirements of the exception in Section 3404.4 of the California Building Code.Thus the existing structure is permitted to remain unaltered. WIND: It is our conclusion that any additional MWFRS wind loading related to the addition of the solar panels is negligible.This conclusion is based on the fact that the panels are installed flush with the roof and do not extend above the peak of the roof and therefore do not change the projected area of the structure. In profile,the additional area from the solar panels is minor when compared to the profile of the entire structure.Therefore the additional wind load,if any,is much less than 10% and meets the requirements of the exception in Section 3404.4 of the California Building Code. Thus the existing structure is permitted to remain unaltered. Page 8 of 29 f . t t - r ✓ t ._ W ' i .may , �•e'1 1sy�r, S v� 4z 4 Am f�� 1 w >f i