Loading...
PMT16-01894 City of Menifee Permit No.: PMT16-01894 29714 HAUN RD. Type: Residential Electrical '(;kCCEL/? MENIFEE, CA 92586 MENIFEE Date Issued: 06127/2016 PERMIT Site Address: 25872 CARAVAN CT, MENIFEE, CA Parcel Number: 358-512-005 92584 Construction Cost: $16,000.00 Existing Use: Proposed Use: Description of INSTALL ROOF MOUNTED SOLAR PV SYSTEM 16 MODULES, 1 INVERTER, 5.2KW Work: Owner Contractor DANIEL MONIZ I E S RESIDENTIAL INC 25872 CARAVAN CT P 0 BOX 947 MENIFEE, CA 92584 STAFFORD.TX 77497 Applicant Phone: 2814982212 ALBERT GORRIN License Number:912189 1 E S RESIDENTIAL INC P O BOX 947 STAFFORD, CA 77497 Fee Description ON Amount($1 Solar, Residential or Small Commercial 1 252.00 Building Permit Issuance 1 27.00 Additional Plan Review Electrical 158 157.50 GREEN FEE 1 1.00 SMIP RESIDENTIAL 1 3.00 General Plan Maintenance Fee-Electrical 1 12.60 $453.10 The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and specifications or from preventing builiding operations being carried on thereunder when in violation of the Building Code or of any other ordinance of City of Menifee.Except as otherwise stated,a permit for construction under which no work is commenced within six months after issuance,or where the work commenced is suspended or abandoned for six months.shall expire,and fees paid shall be forfeited. AA_Bldg Permit_Template.rpt Page 1 of 1 CITY OF MENIFEE (Expires CENSED DECLARATION property who builds or improves thereon,and who contracts forthe projects with a licensed contractor(s)pursuant to the Contractors State License Law). ereby affirm under penalty of perjury that 1 am under provisions of apter9(commencing with section 7000)of Division 3 of the Business and D I am exempt from licensure underthe Contractor's State License Law for ofessions Code and my license is in full force and effect. the following reason: cense Class C-1 a License No. ,l/Z��T_ By my signature below l acknowledge that,except for my personal residence 5A I i01 , Signature f� In which I must have resided for at least one year prior to completion of re improvements covered by this permit.I cannot legally sell a structure that I ER'S COMPENSATION DECLARATIO have built as an owner-builder if it has not been constructed in its entirety by reby affirm under penalty of perjury one of the following declarations:I licensed contractors.I understand that a copy of the applicable law,Section nd will maintain a certificate of consent ofself-insure for worker's 7044 of the Business and Professions Code,is available upon request when ensation,issued by the Director of Industrial Relations as provided for this application is submitted or at the following website: tion 3700 of the Labor Code,for the performance ofwork forwhich www.leeinfo.ra.eov/calaw.html. rmit Is IIIssssu_ed. zq /T(!/� ���/JUDate PROPERTY OWNER OR AUTHORIZED AGENT ve and will maintain workers compensation insurance,as required byn 3700 of the Labor Code,forthe performance of the work forwhich ❑By my signature below I certify to eachof the following:I am the property ermit is issued.My workers compensation Insurance carrier and policy owner or authorized to act on the property owners behalf.I have read this er are: / application and the information I have provided is correct.I agree to comply C3L �!-���L/L,,Z� C�6/✓. li- with all applicable city and county ordinances and state laws relating to r �l building construction.I authorize representatives of this city or county to Policy N XL17DttJ` 41;re) ?L Expires /U ` � •�� enter the above identified property for inspection purposes. (This section need not to be completed is the permit is for one-hundred Date dollars($100)or less PROPERTY OWNER OR AUTHORIZED AGENT o I certify that in the performance of the work for which this permit Is Issued, O"✓w 1�J��� I shall not employ any persons in any manner so as to become subject to the CITY BUSINESS LICENSE q _✓�44V workers compensation laws of California,and agree that if I should becomeIPROPERTYO ZARDOUS MATERIAL DECLARATION subject to the workers compensation provisions of Section 3700 of the Labor Code,I shall forthwith co IV with those provisions. l the applicant or future building occupant handle hazardous material or a Date 6"G'•�6ture containing a hazardous material equal to or greater that the Ap icant ounts specified on the Hazardous Materials Information Guide? WARNING:F I RE TO SECURE WORKER'S COMPENSATION COVERAGE 15es I�dNo UNLAWFUL,AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIESll the)intended use of the building by the applicant or future building AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS($10D,000),INupant require a permit for the construction or modification from South ADDITION TO THE COST OF COMPENSATION,DAMAGES AS PROVIDED FORst Air Quality Management District(SCAQMD)?See permitting checklist IN SECTION 3706 OF THE LABOR CODE,INTEREST,AND ATTORNEYS FEES guidelines CONSTRUCTION LENDING AGENCY es ,Fi'No I hereby affirm that under the penalty of perjury there is a constructionll the proposed building or modified facility be within L000 feet of the lending agency for the performance of the work which this permit is issueder boundary of a school? (Section 3097 Civil Code) es kNNo OWNER BUILDER DECLARATIONS ve read the Hazardous Material Information Guide and the SCAQMD I hereby affirm under penalty of perjury that I am exempt from themitting checklist.I understand my requirements under the State of ifornia Health&Safety Code,Section 25505 and 25534 concerning Contractors License Law for the reason(s)indicated below by the ardous materi reportin checkmark(s)I have placed next to the applicable Rem(s)(Section 7031.5s X ? ll Business and Professions Code).Any city or county that requires a permit to �� Date construct,alter,improve,demolish or repair any structure,priorto itsOPERTYOWNE R AUTHORIZED AGENT Issuance,also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractors State EPA RENOVATION,REPAIR AND PAINTING(RRPI License Law(Chapter9(commencing with Section 7000)of Division 3 of the The EPA Renovation,Repair and Painting(RRP)Rule requires contractors Business and Professions Code)or that he or she is exempt from licensure receiving compensation for most work that disturbs paint in a pre-1978 and the basis for the alleged exemption.Any violation of Section 703LS by residence or childcare facility to be RRP-certified firms and comply with an Applicant for a permit subjects the applicant to a civil penalty of not more required practices.This includes rental property owners and property than($500). managers who do the paint-disturbing work themselves or through their D I,as owner of the property,or my employee with wages as their sole employees.For more information about EPA's Renovation Program visit: compensation,will do( )all of or( )portion of the work,and the structure is www.epa.gov/lead or contact the National Lead Information Center at not intended or offered for sale.(Section 7044,Business and Professions 1-800-424-LEAD(5323). Code;The Contractors State License Law does not apply to an owner of a D An EPA Lead-Safe Certified Renovator will be responsible for this project property who,through employees'or personal effort,builds or improves the property provided that the improvements are not intended or offered for Certified Firm Name: sale.If,however,the building or Improvement is sold within one year of Firm Certification No.: completion,the Owner-Builder will have the burden of proving that it was not built or improved for the purpose of sale. ❑No EPA Lead-Safe Certified Firm is required for this project because: ❑I,as owner of the property am exclusively contracting with licensed contractors to construct the project(Section 7044,Business and Professions Code:The Contractors State License Law does not apply to an owner of a If your project does not comply with EPA RRP rule please fill out the RRP Acknowledgement. BUILDING & SAFETY PERMIT/PLAN • APPLICATION Menifee DATE PERMIT/PLAN CHECK NUMBER TYPE: ❑COMMERCIAL ®RESIDENTIAL ❑MULTI-FAMILY ❑MOBILE HOME ❑POOL/SPA [_-]SIGN SUBTYPE: [-]ADDITION ❑ALTERATION []DEMOLITION []ELECTRICAL []MECHANICAL ❑NEW ❑PLUMBING [-IRE-ROOF-NUMBER OF SQUARES DESCRIPTION OF WORK v N ( 1 6 ¢ ut- a-r I INU',z- . 2 VDC. a-bo PROJECTADDRESS 72q A0 Cou ASSESSOR'S PARCEL NUMBER !f2pCC//'Si)�-bb'5 LOT 4— TRACT PROPERTY OWNER'S NAME D "j ADDRESS 5871 u & FLI PHONE C7/y) 7'.1-7';Let'3 EMAIL APPLICANT NAME AGREILI C-or-r-th) ADDRESS ( o ;F4ILeoqp COICOPJAa 8 PHONE (g5l)Y00-732'i EMAIL oK Ihl Ir CONTRACTOR'SNAME ( S gESIZ>EN-rIAL OWNERBUILDER? ❑YES®NO BUSINESS NAME ADDRESS 'io FLAT a o, `iaL B� PHONE EMAIL CONTRACTOR'S STATE LIC NUMBER 912164 LICENSE CLASSIFICATION G 16 VALUATION$ 11,K. SQ FT ;2 so L SQ FT APPLICANT'S SIGNATURE DATE CITY STAFF USE ONLY DEPARTMENT DISTRIBUTION CITY OF MENIFEE BUSINESS LICENSE NUMBER BURRING PLANNING ENGINEERING FIRE GREEN SMIP (/ INVOICE /]G1G.�p PAIDAMOUNT AMOUNT OCASH OCHECK tt OCREDIT CARD VISA/MC PLAN CHECK FEES PAIDAMOUNT 0CASH 0CHECK# OCREDITCARD VISA/MC OWNER BUILDER VERIFIED OYES 0 NO DL NUMBER NOTARIZED LETTER 0 YES O NO City of Menifee Building&Safety Department 29714 Haun Rd. Menifee, CA 92586 951-672-6777 www.cityofinenifee.us Inspection Request Line 951-246-6213 EsGil Corporation In Partnership with Government for(Building Safety DATE: 06/22/16 rJU LICANT / IS. JURISDICTION: City of Menifee N REVIEWER ❑ FILE PLAN CHECK NO.: PMT16-01894 SET: I PROJECT ADDRESS: 25872 Caravan Ct. PROJECT NAME: DANIEL MONIZ 6,000 Watts Solar Photovoltaic System ® The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. ❑ The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. ❑ The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. ❑ The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. ❑ The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. ❑ The applicant's copy of the check list has been sent to: ® Esgil Corporation staff did not advise the applicant that the plan check has been completed. ❑ Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: — Telephone #: Date contacted: `- (t(y / ) Fax #: Mail Telephone Fax in Person E-mail: ❑ REMARKS: By: Sergio Azuela Enclosures: EsGil Corporation ❑ GA ❑ EJ ❑ PC 06/16 9320 Chesapeake Drive, Suite 208 ♦ San Diego,California 92123 ♦ (858) 560-1468 ♦ Fax(858)560-1576 City of Menifee PMT16-01894 06/22/16 [DO NOT PAY— THIS IS NOT AN INVOICE] VALUATION AND PLAN CHECK FEE JURISDICTION: City of Menifee PLAN CHECK NO.: PMT16-01894 PREPARED BY: Sergio Azuela DATE: 06/22/16 BUILDING ADDRESS: 25872 Caravan Ct. BUILDING OCCUPANCY: TYPE OF CONSTRUCTION: BUILDING AREA Valuation Reg. VALUE ($) PORTION ( Sq. Ft.) Multiplier Mod. Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code mnf Imanual Input Bldg. Permit Fee by Ordinance W Plan Check Fee by Ordinance W Type of Review: ❑ Complete Review ❑ Structural Only ❑Repetitive Fee ❑ Other Repeats � 1.51 Hrs. EsGil Fee 1 $105.00 $157.50 Based on hourly rate Comments: 1 1/2 hours plan review. Sheet 1 of 1 macvalue.doc+ & ASSOCIATES CJ�ft/C�!/!Q�VQlflltP�'!J STRUCTURAL CALCULATIONS FOR City of Menifee Building & Safety Dept. JUN 15 2016 PHOTOVOLTAIC ived ARRAY Moniz Residence 25872 Car v C Menifee, 4 Q'3o ES L/ C3 S 1 r . 1231 17 3 CLI NT: S Residential JO NO: 09-3457 M1 I/\ 175 E.WILBUR ROAD, STE 103 ^ THOUSAND OAKS, CA 91360 P 805.496.2100 - 1605.496.2442 ° e solar@VinciSE.com DATE: 6/10/2016 ASSOCIATES SHEET: 1 PROJECT: Moniz Residence 31ruclaral 6agnfeera JOB No: 09-3457 25872 Caravan Ct 175 E.W ILBUR ROAD.STE 103 •THOUSAND OAKS.CA 913GO ENGR. JRV Menifee, CA 92584 p805496.2100 • f605496.2442 • e solar@VlnclSE cam CLIENT: IES Residential DESIGN DATA: ROOF DESIGN LOAD: ROOFING ( Concrete Tile ) = 12 psf SHEATHING = 2 ROOF RAFTERS I TRUSS = 2 MISCELLANEOUS = 1 ROOF RAFTER/TRUSS DESIGN DEAD LOAD = 17.0 psf CEILING 8 INSULATION = 3.25 MISCELLANEOUS = 1.25 DESIGN DEAD LOAD = 21.5 psf DESIGN LIVE LOAD = 20 psf DESIGN SNOW LOAD — 0 psf WIND DESIGN CRITERIA: BASIC WIND SPEED = 110 mph WIND EXPOSURE = C NUMBER OF STORIES = 1 SOLAR MODULE Solar Module Width: = 41.2 in Solar Module Length: = 61.4 in Solar Module Area — 17.57 112 Solar Module Dead Load = 2.6 psf Number of PV Modules = 16 Number of PV Mounts to Roof = 24 Maximum Spacing of Mounts = 6 ft,D.C. Tributary Area to Mounts 17.57 fe x ( 16 ! 24 } = 11.71 ft2 (Average) ( 6 It oc x 61.4 in / 12"/ft)/2 = 15.35 ft2 (Worst Case) Solar Module Vertical Support Point Load: 15.35 ft2 x 2.60 psf = 39.9 Ibs TOTAL AREA OF ADDED SOLAR PANELS ( 3.43 ft x 5.12 ft ) X ( 16 Modules ) = 281.1 ft2 DATE 6/10/2016 1 a J C, U & ASSOCIATES SHEET: 2 PROJECT: Moniz Residence 31mclurvI(5nginee s JOB NO 09-3457 25872 Caravan Ct 175E.WILBUR ROAD.STE103 -THOUSAND OAKS.CA 91360 ENGIR JRV Menifee,CA 92584 805.496.2100 805.496.2442 solar@VlnclSE.com CLIENT: IES Residential DESIGN CONNECTION TO ROOF TO RESIST WIND UPLIFT ' REFER TO NEXT SHEET FOR UPLIFT FORCE CALCULATIONS 318'x 314'Hex Boil ZONE 1 UPLIFT = 23.6 psf 2.6 psf 316'Flat Washer lyp. Design Farce=( Uplift x(0.6) ) -2.6 psf ` - 7I Net Uplift= 11.6 psf le Roar Hook 1.50 Connections per Module (MIN) �Concmte s TBe I 5116•x3'Lag scmwc '�;1�; J' __ 16 Modules, 24 Connections Use 5116'Flat Washers �^ 2 2 V2'Min.Emhetlment� Max Trib Area = 15.35 ft UPLIFT/CONN. = 15.4 ft2 x 11.6 psf = 177.7 Ibs/conn -= ---`� PER 2012 NDS (TABLE 11.2A) Zx Ran \L-. PALLow = 258 Ibs/in x CO x CI for(1) 5/16" lag bolt WITH 2.00" PENETRATION INTO JOIST PALLow = 2.00 " x 413 Win = 825.6lbs > 178lbs Therefore O.K. FACTOR OF SAFETY: F.O.S. = 4.65 > 1.5 Therefore O.K. ZONE 3 UPLIFT = 58.9 psf -2.6 psf ZONE 2 UPLIFT = 39.3 psf -2.6 psf Design Force=( Uplift x(0.6)) -2.6 psf Design Farce=(Uplift x(0.6) ) -2.6 psf Net Uplift = 35.4 psf Net Uplift= 23.6 psf 1.50 Connections per Module (MIN) 1.50 Connections per Module (MIN) 16 Modules, 24 Connections 16 Modules, 24 Connections Max Trib Area = 15.35 ft2 Max Trib Area = 15.35 ft2 UPLIFT/CONN. = 15.4 ft2 x 35.4 psf UPLIFT/ CONN. = 15.4 ft2 x 23.6 psf = 542.8 Ibs/conn = 362.3 Ibs/conn PER 2012 NDS (TABLE 11.2A) PER 2012 NDS (TABLE 11.2A) PALLow= 258 Ibs/in x CD x Ct PALLOw = 258 Ibs/in x CD x Ct for(1) 5116" lag bolt for(1) 5/16" lag bolt WITH 2.00" PENETRATION INTO JOIST WITH 2.00" PENETRATION INTO JOIST PALLow= 2.00 " x 412.8 Win PALLOW = 2.00 " x 413 Win = 825.6lbs > 543lbs = 825.6lbs > 362lbs Therefore O.K. Therefore O.K. FACTOR OF SAFETY: FACTOR OF SAFETY: F.O.S. = 1.52 > 1.5 F.O.S. = 2.28 > 1.5 Therefore O.K. Therefore O.K. PROJECT: 58?2fC Residence PAGE: 3 CLIENT: '25872 Caravan Ct McMfae,CA 9256a DESIGN BY: JftV JOB NO.: '1S3467 DATE: 0611DI16 REVIEW BY: Wind Ana[ ]afor Low-rise Bulddinn ,Based on ASCE 7-2010 1 CSC 2013 INPUT DATA Exposure category(e,C D.ASCE 7-1U 28 731 C Importance Imponalutce factor(ASCE 7q0 Table 1.5-2) Iw = 1.00 for all Category Basic wind speed(ASCE 7-1026.5.1 or 201215q V = 110 mph Topographic faftf(ASC:E 7.10 2e.e a Table 2e.ea) Ka = 1 Flat Building height to save he 10 it Building height to ridge hr = 15 it _ 1. Building length L = 51.16667 ft Building width B = 26.31429 8 L-B-11 Effed[va area of components(or Soler Panel me) A 17.56722 8e DESIGN SUMMARY Max horizontal force normal to building length,L,face = 12.28 kips,SO level(LRFD level),Typ. Max horizontal forte normal to building length,B,face = 5 5B kips Max total honmIN3l torsional had = 66.34 8-kips Max total talerand force - 22 86 kips ANALYSIS Velwty pressure qh=0.00256 Kh Ka KeV2 22.38 psi where: or=ve:ocity pressure at mean=1 height h (Eq.28.3-1 page 298 8 Eq.30.3-1 page 316) Kh=velocity pressure exposure coefficient evaluated at height,h.(7m.2e.3-1.ae 299) = 0.05 KI=wind dhectionalily factor.(Tab.26 6-1,for bu:deg,papa 250) = 0.85 h=mean root height = 12.50 8 <60 it,[Satisfactory] (ASCE 7.10 26.2.1) c Min(L,B),[5atidactoryl (ASCE 7-10 26.2.2) Design pressures for MWFRS p=qh[(G Cor)-(G Cp)l where. to=pressure In appropriate zone.(Eq.28.4-1,page 298). p hn= 16 psi(ASCE 7.10 28.4A) G Car=product of gust effect(whir and external pressure coefficient,see table below.(Fig.28.4-1.page 300 6 301) G Cy,=product of gust effect factor and internal pressure coeffidenl.(Tab.26.11-1.Enclosed Budding.page 258) 0.15 or .0.18 a-width of edge strips,Fig 26.4-1.note 9,page 301, MAX[MIN(O.18,0.1L,0.4h),MIN(0.046,0.041-),3] = 3.00 It Net Pressures(Psi),Basic Load Came Net Pressures ,Torsional Load Ceres Roof angle 0 = 20.81 1 Roclf angle 6 = 0.00 Root an le 0 = 20.81 Surface Na(t�Pn=ue With Nati MmoevAlh Such. NO Prwruls wlN G CT, (•GCr.) OCcr (-GC,.) (.GC,,) 64r (�GCIi) {-GCoI) 1 0.53 7.89 15,94 -0.45 -14.10 -6.04 1T 0.53 1.97 3.99 2 .0.62 .17.84 -9.79 .0.69 -19.47 -11.41 2T -0.52 4.46 -2.45 3 -0.48 -14.68 -0,82 -0.37 -1231 -4.25 3T .0.48 -3.67 -1.66 4 -0.43 -13.54 -5A9 -0.45 .14.10 -6.04 4T -0.43 .3.39 -1.37 5 0.40 4.92 1298 Root an le 0 - 0.00 6 -0.29 -W.52 -246 Sw1am Nrl Pressure M(h 1E 0.79 13.68 21.73 -0.46 .14.77 -6.71 0C0r 2E -0.96 .25.55 -17.50 -1.07 -27.98 -1992 5T 0.40 1.23 3.25 3E -0.68 -19.18 -11.12 -0.53 .15.89 -7.83 6T -0.29 -2.63 -0.62 4E .0.63 -18.06 -10.01 .0.43 -14.77 -6.71 5E 0.61 9.62 17.60 6E 1 -0.43 1 .13.65 1 -5.60 if r r s a rt x s sr ]r Lx IC 1 11 1 r x i rppxer Re to i4x0rapCfM N[11P[Mtt rPxl}r e..rW px6mx PRrc[x¢CWx[a r,beILOM[aM xe[Im[CLGMPtn �ax9 xVCroY Load Cosa A(Transverse) Load Cosa B(Longitudinal) Load Case A(Transverse) Load Case 8(Longitudinal) 4 Basic Load Case A ransverse Direction Basic Load Casa B(Lon Itudlnal Direction) HBO I Procure a with Area PM5u, W with Surtece (s') (-GCe.) SurtatB (fl) (+GCPI) I I-GCPI) 1 452 3.56 7.20 2 636 -12.38 -7.26 2 636 -11.34 -6.22 3 636 -7.83 -2.70 3 636 -9 33 -4.21 5 266 1.31 3.45 4 452 -6.12 -2.48 6 266 -2.79 •0.65 1E 60 0.82 1.30 2E 84 -236 -1.68 2E 84 -2.16 -1.48 3E S4 -1.34 -0.66 3E 84 -1.62 -0.94 5E 63 0.61 1.12 4E 60 4.08 460 6E 63 -087 -0.35 Horiz. 10.68 10.68 Hertz. 5.58 5.58 P Vert. -22.86 -1201 i Vert. -19.12 .859 ten wend Honz. 1228 12.20 Un Wra Honz. 5.26 5.26 28.44 Vert. -21.54 .2154 2844 Vert -21.54 .21.54 Toralonal Load Case A(Trans me Direction Torsional Load Cass B ILonfilludloal Dlmction Area Prssv k will+ Tonscf 114; Haa Pressure Wth To,s]. It-M SO= (fl') (+GCPI) (•G('rol) NC+CPI) (-GCP.) Sad= In'1 HGCPI) (-GCP,) (NGCPi) (-GC,.) 1 196 1.54 3.12 17 35 2 636 -12.38 -7.26 -7 A 2 276 492 -2.70 -20 •11 3 636 -7.83 -2.70 4 1 3 276 405 -1.83 16 7 5 101 0.50 1.31 2 6 4 196 -2 65 -1.07 30 12 6 101 -1.06 -0.25 5 1 1E 60 0.82 1.30 19 29 2E 84 -2.36 -1.68 20 14 2E 84 -2.16 -1.48 -17 •12 3E 84 -1.34 -0.66 -11 -0 3E 84 -1.62 -0.94 13 B 5E 63 0.61 1A2 7 13 4E 60 -1.08 -0.60 24 14 6E 63 -0.87 -0.35 10 4 1T 256 0.50 1.02 -6 •13 5T 164 0.20 0.53 -1 .3 2T 360 -1.61 -0.88 7 4 6T t6d -043 -0.70 -3 -1 3T 360 -1.32 -0.60 .6 3 Total Hodz.Torsional Load.Mr 27.1 1 27.1 47 256 117 -0.35 -11 •4 Tplal Hodz.Torsional Load,Mr 66 66 fission pressures for components and cladding > : s xr p=4nl(G CP)-(G CoI)) esf1�� �'-+--+ I' where: p=pressuleoncamponenl.(Eq.30.4.1,pg 310) r"°• la sins'• + +' b Ltd pmm= 16.00 psi(ASCE 7-10 3022)GCP=external pressure coeRfNenl. Walls � ' si see table below.(ASCE 7.10 304.2) Roof e.+• Roof s•+- EHaollwI Zone Zone2 Zone Zone ZBne5 AMa(It't GCP I -GCP GCP I -GCP I Gee -GC,. GC, I •GCe GCP •GCP C 17,56722 0.45 -0BB 045 -1.58 045 -245 096 -t06 0.96 -1.31 Comp.a Cladding 1 i Zane Zenl ZBne4 zones Pressure ;;; ZOM r . Vml11n I rY IM I Pu IM aw I Pw M I P." u- (PSI) 16.00 1 -2362 1 16.00 1 -39.34 1 1600 I •5B 93 1 2544 1 -2768 2544 1 -33.43 Note: If the effective area Is met Solar Panel area,the only zone 1,2,or 3 apply. DATE: 6/10/2016 G' ` N i & ASSOCIATES SHEET: 5 PROJECT: Moniz Residence cSln rlara/Cngineer4 JOB NO.: 0"457 25872 Caravan Ct 175 E.WILBUR ROAD,STE 103 -THOUSAND OAKS,CA 91360 ENGRJ JRV Menifee, CA 92584 p 805 496 2100 • 1005.4962442 • a IarQVinciSE.wm CLIENT: IES Residential LATERAL FORCES: (Base Shear Calculations - 2013 CBC) SEISMIC: Site Class: D (Use D if unknown) S1= 0.600 (USGS Software) Ss= 1.50 (USGS Software) F,= 1.5 (Table 1613.3.3(2)) Fa= 1.0 (Table 1613.3.3(1)) I = 1.0 (Table 11.5-1 ASCE 7-10) R = 6.5 (Table 12.2-1 ASCE 7-10) SMs = Fa*Ss= 1.5 (Eq, 16-37) SOB= 2/3* SMS= 1.00 (Eq. 16-39) SMI= F�*S7= 0.9 (Eq. 16-38) Sol = 213*SM1 = 0.60 (Eq. 1640) TL= 8 s (Figure 22-12 ASCE 7-10) T= C7*(h )` = 0.112 s (Eq. 12.8-7) CI= 0.02 (Table 12.8-2 ASCE 7-10) hn= 10.0 ft x= 0.75 (Table 12.8-2 ASCE 7-10) **GOVERNS** VMIN = ( SDS))( R/1) = 0.15 W (Eq. 12.8-2 ASCE 7-10) NEED NOT EXCEED: IF T <_TL USE: V = ( So1)/T*( R/I) = 0.82 W (Eq. 12.8-3 ASCE 7-10) IF T>TL USE: V = (SD1)*(TL)/T2*( R/1) = 55.38 W (Eq. 12.8-4 ASCE 7-10) SMALL NOT BE LESS THAN: V = 0.01 W (Eq. 12.8-5 ASCE 7-10) ZUS(js Design Maps Summary Report (� User--Specified Input Building Code Reference Document 2012 International Building Code (which utilizes USGS hazard data available In 2008) Site Coordinates 33.685590N, 117.15452OW Site Soil Classification Site Class D-"Stiff Soll' Risk Category I/II/III cA.KEvt U t i } omdan �pn{�Dm�rtd Hemet l ,hid, I - W--.rFE M'rddMFan Chi Sr/ t t ba �W-in�C lsrh-� g9hro q� s� xit tsor� ¢} "Pon Rd Elsinore °o4rtiuG0111 j ; edcoHili .sw_ned -. 4fA - x, y` .iEr - � uSGS-Provided Output A SS = 1.500 g Sin= 1.500 g S05= 1.000 g St = 0.600 g SM3 = 0.900 g Sol = 0.600 g For Information on how the SS and SS values above have been calculated from probabilistic (risk-targeted) and deterministic ground motions in the direction of maximum horizontal response, please return to the application and select the"2009 NEHRP"building code reference document. MCER Response Spectrum Design Response Spectrum 1.6s 1.50 l.to 1.3s o.5e 1.70 o.es LOS 0.77 .^.P. 0.30 0.66 N 0.75 (A 0.55 0.90 0,44 Q45 0.77 0.30 0.12 0.15 0.11 D,DD a.00 0.00 0.20 0.40 0.60 0.60 1.00 1.20 3.40 l.60 1.00 LOD a 00 030 0.40 0.60 0.80 L.DO I.20 1.40 I.60 7.80 2 00 Period.T(sect Period,T(sm) Although this information is a product of the US.Geological Survey,we provide no warranty,expressed or Implied,as to the accuracy of the data contained lhereln.This tool is not a substitute for technical subject-matter knowledge. DATE 6/10/2016 it & ASSOCIATES SHEET: 7 PROJECT: Moniz Residence c51rudaral Cingineers JOBNO.: 09-3457 25872 Caravan Ct 175 E.W ILBUR ROAD.STE 103 •THOUSAND OAKS,CA 91360 ENGR.: JRV Menifee, CA 92584 p805496.2100 • 1805496,2442 • esolar®VIncISE.com CLIENT: 'ES Residential LATERAL FORCES 2013 CBC: (BASE SHEAR- Conservative) Ft RODE= 5.0 ft SEISMIC BASE SHEAR: V= 0.15 W (SEE PREVIOUS) h1 = 10.0 ft Ft ROOF= 22 PSF WALLS = 7 28.5 x 0.154 4.38 PSF WIND LOADS: Governs Ps= Akrt1wN30 (E9. 6-1) A= 1.21 P530A= 19.20 psf PSA 23.27 psf iw, 1.00 P530B= -10.00 psf pse -12.12 psf ke= 1.00 Ps3oC= 12.70 psf psc 15.39 psf Ps360= -5.90 psf No -7.15 psf F1DLT: _ ( 5 ft + 10 ft/2 )x (23.2704 psf+12.12 psf) = 354 lb/ft F1ASII: = 353.90 lb/ft x 0.6 = 212 Iblft DATE 6/10/2016 `s' O r:l 0 I & ASSOCIATES SHEET: 8 PROJECT: MOnlz Residence c$lraclural Cngineer.r JOB NO. 09-3457 25872 Caravan Ct 175 E.WILBUR ROAD,STE 103 •THOUSAND OAKS,CA 91360 ENGR.: JRV Menifee, CA 92584 p805.4962100 • f805496.2442 • esolar@VinclSE.com CUENT: IES Residenfial CHECK IMPACT OF NEW SOLAR PANELS ON SEISMIC LOAD y\� 3" m'n, NV AC I� r NO- TOTAL ROOF AREA: ( 51.2ft x 26.3ft ) + ( 20.5ft x 19.Oft ) + ( 23.4 ft x 21.9 ft ) + ( 0.0 ft x 0.0 ft ) = 2248.2981 ft2 EXISTING ESTIMATED SEISMIC LOAD (BASE SHEAR) 2248.3 ft2 x 4.38 psf = 9857.92 Ibs AREA OF ADDED SOLAR PANELS ( 5.12 ft x 3.43 ft ) X ( 16 PANELS ) = 281.1 ft2 WEIGHT OF PANELS: 2.6 psf ADDED SEISMIC LOAD: 2.6 psf x 281.1 ft2 x 0.15 = 112.4 Ibs % INCREASE = 112.4 = 1.1% < 10% 9857.922616 Therefoye G.K. 61 COMPANY PROJECT ® CIATES WoodWorkS StructuralVINCIBASSO Sctural Engineers .�+..v.a. VincISE.com June 10,201613:38 Check Top Chord on Existing Truss Design Check Calculation Sheet WoodWorks Sizer 10.2 Loads: Location (ft] Magnitude Unit Load Type Distribution Pat- tern Start End Start End Roof DL Dead Full Area No 17. 00 (24.0)* psf Roof LL Roof constr. Full Area Yes 20.00 (24.0)* psf PV1 Dead Point No 0.50 40 lbs PV2 Dead Point No 4 .50 40 lbs PV3 Dead Point No 6.00 40 lbs lbs PV4 Dead Point No 10.00 140 plf Self-weight Dead Full UDL No *Tributary Width (in) Maximum Reactions (lbs) and Bearing Lengths (in) : __--- 17'-0.7" -- ----_ ----- 0 3' 94. 16' Unfactored: 319 101 Dead J66 318 123 Roof Live Factored: 637224 TotalBearing: 0.540.50* Length ** 0.22 Min req'd 0.59*Minimum bear n lent settin end su orts **Minimum bearing length governed by the required width of the supporting member. Lumber-soft, DAT-L, No.2, 2x4(1-112"x3-112") Supports:All-Timber-soft Beam, D.Fir-L No.2 Roof joist spaced at 24.0"c/c;Total length: 17'-0.7; Slope: 19.0 deg; Lateral support: top=full, bottom=at supports; Repetitive factor: applied where permitted(refer to online help); C L` WoodWorks® Sizer SOFTWARE FOR WOOD DESIGN Check Top Chord on Existing Truss WoodWorks®Sizer 10.2 Page 2 Analysis vs. Allowable Stress (psi) and Deflection (in) using NDS zolz Criterion rAnallysls Value Design Value Analysis/Design Shear v = 88Fv' = 225 fv/Fv' = 0.39 Bending(+) b = 1202 Fb' = 1941 fb/Fb' = 0.62 Bending(-) b 1354 Fb' = 1837 fb/Fb' = 0.96 Deflection: Interior Dead 0.10 = L/796 0.38 Live 0.17 = L/476 0.46 = L/180 Total 0.28 = L/298 0.69 = L/120 0.40 Cantil. Dead 0.25 = L/154 0.94 Live 0.40 = L/95 0.42 = L/90 1.02 Total 0.65 = L/5B 0.63 = L/60 Additional Data: FACTORS: F/E(psi)CD CM Ct CL CF Cfu Cr Cfrt Ci Cn LC# Fv' 180 1.25 1.00 1.00 - - - - 1.00 1.00 1.00 B Fb'+ 900 1.25 1.00 1.00 1.000 1.500 1.00 1.15 1.00 1.00 - 7 Fb'- 900 1.25 1.00 1.00 0.946 1.500 1.00 1.15 1.00 1.00 _ 2 625 - 1.00 1.00 - - - 1.00 1.00 Fcp' _ E' 1.6 million 1.00 1.00 - - 1.00 1.00 - 7_ 1.00 1.00 - 7 Emin' 0.58 million 1.00 1.00 - - - CRITICAL LOAD COMBINATIONS: Shear : LC #8 - D+Lr (pattern: LL) , V = 329, V design = 307 lbs Bending(+) : LC #7 = D+Lr (pattern: L_L) , M = 307 lbs-ft Bending(-l : LC #2 = D+Lr, M = 44D lbs-ft Deflection: LC #7 = (live) LC 07 = (total) D=dead L=live S=snow W=wind I=impact Lr=roof live Lc=concentrated E=earthquake All LC's are listed in the Analysis output Load Patterns: s=S/2, X=L+S or L+Lr, _=no pattern load in this span Load combinations: ASCE 7-10 / IBC 2012 CALCULATIONS: Deflection: EI = 9e06 lb-in2 "Live" deflection = Deflection from all non-dead loads (live, wind, snow...) Total Deflection = 1.00 (Dead Load Deflection) + Live Load Deflection. Bearing: Allowable bearing at an angle F'theta calculated for each support as per NDS 3.10.3 Design Notes: 1.WoodWorks analysis and design are in accordance with the ICC International Building Code(IBC 2012), the National Design Specification(NDS 2012),and NDS Design Supplement. 2. Please verify that the default deflection limits are appropriate for your application. 3. Continuous or Cantilevered Beams: NDS Clause 4.2.5.5 requires that normal grading provisions be extended to the middle 2/3 of 2 span beams and to the full length of cantilevers and other spans. 4.Sawn lumber bending members shall be laterally supported according to the provisions of NDS Clause 4.4.1. 5.SLOPED BEAMS:level bearing is required for all sloped beams. B. FIRE RATING: Joists,wall studs,and multi-ply members are not rated for fire endurance. 7.The critical deflection value has been determined using maximum back-span deflection. Cantilever deflections do not govern design.