PMT16-01661 City of Menifee Permit No.: PMT16-01661 29714 HAUN RD. Type: Residential Addition <ACCELA— MENIFEE, CA 92586 MENIFEE Date Issued: OS/27/2016 PERMIT Site Address: 25292 ANTELOPE RD, MENIFEE, CA Parcel Number: 329-340-003 92585 Construction Cost: $18,000.00 Existing Use: 1 &2 Family Residence Proposed Use: Description of INSTALL 6'x 160 L FT CITY STD BLOCK WALL WITH 4 CITY STD U PILASTERS, NO ELECTRICAL Work: Owner Contractor RODRIGO ALVAREZ 25292 ANTELOPE ROAD MENIFEE, CA 92585 Applicant License Number: RODRIGO ALVAREZ 25292 ANTELOPE ROAD MENIFEE, CA 92585 Phone:9514907821 Fee Description OQt rr Amount f81 Building Permit Issuance 1 27.00 Wall/Fence,standard 1 83.00 GREEN FEE 1 1.00 SMIP RESIDENTIAL 1 3,00 General Plan Maintenance Fee-Building 1 4.15 $118.15 The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and specifications or from preventing builiding operations being carried on thereunder when in violation of the Building Code or of any other ordinance of City of Menifee.Except as otherwise slated,a permit for construction under which no work is commenced within six months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be forfeited. AA_Bldg_Permil_Template.rpt Page 1 of 1 CITY OF MENIFEE LICENSED DECLARATION property who builds or improves thereon,and who contracts for the projects with a licensed contractor(s)pursuant to the Contractors State License Law). I hereby affirm under penalty of perjury that I am under provisions of Chaptef9(commencing with section 7000)of Division 3 of the Business and o 1 am exempt from Ilcensure under the Contractor's State License Law for Professions Code and my license is in full force and effect. the following reason: License Class License No. By my signature below I acknowledge that,except for my personal residence Expires Signature in which I must have resided for at least one year prior to completion of improvements covered by this permit.I cannot legally sell a structure that I WORKER'S COMPENSATION DECLARATION have built as an owner-builder if it has not been constructed In its entirety by ❑I hereby affirm under penalty of perjury one of the following declarations:I licensed contractors. u stand that a copy of the applicable law,Section have and will maintain a certificate of consent of self-insure for workers 7044 of the 8usines rofessions Code,is available upon request when compensation,issued by the Director of Industrial Relations as provided for this application is s411 a at the following website: by Section 3700 of the Labor Code,for the performance of work for which www.le inf .cal ov cola rtml. this permit is issued. Policy# Date PROPERTY 0 R ALIVadJR724AGENT ❑I have and will maintain workers compensation insurance,as required by section 3700 of the Labor Code,for the performance of the work for which a By my signatJanntV ifyto each of the following:I am the property this permit is issued.My workers compensation insurance carrier and policy owner or authn the property owners behalf.I have read this number are: application antion I have provided is correct.I agree to comply with all applicamy ordinances and state laws relating to Carrier building const Vz presentatives of this city or county to Policy# Expires enter the abovape inspection purposes. r (This section need not to be completed is the permit is for one-hundred Date dollars($100)or less PROPERTY OWe OR AU D AGENT o I certify that in the performance of the work for which this permit is issued, I shall not emoloY any persons in any manner so as to become subject to the CITY BUSINESS LICENS # workers compensation laws of California,and agree that if I should become HAZARDOUS MATERIAL DECLARATION subject to the workers compensation provisions of Section 3700 of the Labor Code,I shall forthwith comply with those provisions. Will the applicant or future building occupant handle hazardous material or a mixture containing a hazardous material equal to or greater that the Applicant Date amounts specified on the Hazardous Materials Information Guide? WARNING:FAILURE TO SECURE WORKER'S COMPENSATION COVERAGE 15 ❑Yes D No UNLAWFUL,AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES Will the intended use of the building by the applicant or future building AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS($100,000),IN occupant require a permit for the construction or modification from South ADDITION TO THE COST OF COMPENSATION,DAMAGES AS PROVIDED FOR Coast Air Quality Management District(SCAQMD)?See permitting checklist IN SECTION 3706 OF THE LABOR CODE,INTEREST,AND ATTORNEYS FEES for guidelines CONSTRUCTION LENDING AGENCY ❑Yes ❑No 1 hereby affirm that under the penalty of perjury there is a construction Will the proposed building or modified facility be.within 1000 feet of the lending agency for the performance of the work which this permit Is issued outer boundary of a school? (Section 3097 Civil Code) ❑Yes ❑No OWNER BUILDER DECLARATIONS I have read the Hazardous Material Information Guide and the SCAQMD I hereby affirm under penalty of perjury that I am exempt from the permitting checklist.I understand my requirements under the State of California Health&Safety Code,Section 25505 and 25534 concerning Contractors License Law for the reason(s)indicated below by the hazardous material reporting. checkmark(s)I have placed next to the applicable item(s)(Section 7031.5 oYes ❑No Business and Professions Code).Any city or county that requires a permit to Date construct,alter,Improve,demolish or repair any structure,prior to its PROPERTY OWNER OR AUTHORIZED AGENT issuance,also requires the applicant for the permit to file a signed statement that he or she Is licensed pursuant to the provisions of the Contractors State EPA RENOVATION,REPAIR AND PAINTING IRRPI License Law(Chapter 9(commencing with Section 7000)of Division 3 of the The EPA Renovation,Repair and Painting(RRP)Rule requires contractors Business and Professions Code)or that he or she is exempt from Ilcensure receiving compensation for most work that disturbs paint in a pre-1978 and the basis for the alleged exemption.Any violation of Section 7031.5 by residence or childcare facility to be RRP-certified firms and comply with an Applicant for a permit subjects the applicant to a civil penalty of not more required practices.This includes rental property owners and property than($500). managers who do the paint-disturbing work themselves or through their a 1,as ownerof the property,or my employee with wages as their sole employees.For more Information about EPA's Renovation Program visit: compensation,will do( )all of or( )portion of the work,and the structure is www.eoa.zov/lead or contact the National Lead Information Center at not Intended or offered for sale.(Section 7D44,Business and Professions 1-800-424-LEAD(5323). Code,The Contractors State License Law does not apply to an owner of a ❑An EPA Lead-Safe Certified Renovator will be responsible for this project property who,through employees'or personal effort,builds or improves the property provided that the improvements are not intended or offered for Certified Firm Name: sale.if,however,the building or improvement is sold within one year of Firm Certification No.: completion,the Owner-Builder will have the burden of proving that it was not built or improved for the purpose of sale. ❑No EPA Lead-Safe Certified Firm is required for this project because: ❑I,as owner of the property am exclusively contracting with licensed contractors to construct the project(Section 7044,Business and Professions Code:The Contractors State License Law does not apply to an owner of a If your project does not comply with EPA RRP rule please fill out the RRP Acknowledgement. BUILDING SAFETY PERMIT/PLAN CHECK APPLICATION Menifee DATE J —pZ6— PERMIT/PLAN CHECK NUMBER TYPE: O COMMERCIAL /PRESIDENTIAL O MULTI-FAMILY O MOBILE HOME O POOL/SPA O SIGN SUBTYPE: O ADDITION O ALTERATION O DEMOLITION O ELECTRICAL O MECHANICAL O NEW O PLUMBING 0 RE-ROOF-NUMBEROFSQUARES DESCRIPTION OF WORK ` �r o, PROJECT ADDRESS 2 ASSESSOR'S PARCEL NUMBER - �•n)- 7 LOT TRACT OWNER NAME j A eZ ADDRESS �ql f a l.4 PHONE`gSI "1 -7 9);11 EMAIL APPLICANT NAME f Z - r i r� ^ ADDRESS Son `- ` PHONE `ll.5 1 ) !s3S r 9 3:2- EMAIL , CONTRACTOR'S NAME OWNER BUILDER? P YES O NO BUSINESS NAME ADDRESS PHONE EMAIL CONTRACTOR'S STATE LIC NUMBER LICENSE CLASSIFICATION VALUATION$ 1, SO FT L SO FT APPLICANT'S SIGNATURE DATE - C� - ';;TAFF USE ONLY hULPARTMEN1 DISTRIBUTION CITY OF MENIFEE BUSINESS LICENSE NUMBER LANNING ENGINEERING FIREINVOICE GREEN SMIP PAIDAMOUNT , OCHECK# O CREDIT CARD VISA/MC CHECKFEES PAIDAMOUNT 0CASH 0CHECK# 0CREDITCARD VISA/MC ILDER VERIFIED 'YES 0 NO DL NUMBER NOTARIZED LETTER O YES O NO City of Menifee Building&Safety Department 29714 Haun Rd. Menifee, CA 92586 951-672-6777 www.cityofinenifee.us Inspection Request Line 951-246-6213 ' ! 7 I O City of Menifee Building & Safety Dept. M 2 7 .2016 w CITY�f, MENIFEE CG'IVOd O BUINiI� AND SAFETY DEPARTMENT PLAN bPROVALMEMO I REVIEWED BY f DATE I "Appr;-,al of these plans shall not be cop sn ued to be a permit for,or an approv of,any violation of any provisions of the federal,state or city O regulatiuns and ordinances. This set of'approved plans must be kept on the jobsite until completion. • , i i I I � rmYC (xC/ E LLt P I too 1= FOOTING OPTION "A" C FOOTING OPTION "B" #4 HORIZONTAL REBAR (USE BOND BEAM BLOCK) of Menif a E; 9 & Safe Dept. 6" OR 8"BLOCK �Y 2 7 -2 16 "H" H" HEIGHT FROM TOF O.C.#4 HORIZONTAL AT 32"mAx. cetv TOP OF FOOTING (USE BOND BEAM BLOCK) OFF G SEE TABLE"A'T SEE TABLE"B" FOR REBAR SIZE FOR REBAR SIZE A AND SPACING ANDSPACING LOCATE REBAR IN CENTER OF CELL) (LOCATEREBAR.NCENTEROFCELU I L FINISH GRADE C M-44 REBAR IIII CON INUOUS 12" (2)-#4 REBAR rMlill CONTINUOUS Jill== REVERSE DIRECTION OF W W HOOK ON EVERY OTHER REBAR "(FOOTI'N'GWIDTH)l �(FOOT NG WIDTHI) SEETABLE"A" SEETABLE"B" ALL FOOTINGS ADJACENT TO SLOPES TO BEAT LEAST 51 To TABLE "A" DAYLIGHT AS SHOWN BELOW. TABi F "B" "H" "W" VERTICAL "H" "W" VERTICAL REINFORCEMENT REINFORCEMENT 37 17" #4 Ca 48" O.C. 3' 19" #4 @ 48" O.C. 4' 20" #4 La 48" O.C. 4' 22" #4 @ 48" O.C. 5' 23" #4 @ 48"O.C. 51 29" #4 @ 48" O.C. 6' 29" #4 @ 24" C.C. eorroM IN. OF 5'Y— 6' 34" #4 @ 24" O.C. FOOTING NOTES: CHECK WITH THE BUILDING DEPARTMENT TO 1)THIS DESIGN DOES NOT ALLOW GRADE DIFFERENTIALS OF VERIFY IF A BUILDING PERMIT IS REQUIRED. MORE THAN 6"ON OPPOSING SIDES OF THE WALL. THIS is WHEN A PERMIT IS REQUIRED,THE FOLLOWING NOT A RETAINING WALL- INSPECTIONS ARE REQUIRED: 2)FENCE HEIGHTS ARE REGULATED—CONSULT ZONING 1)FOOTING EXCAVATION TRENCH CLEAN WITH REGULATIONS BEFORE BEGINNING CONSTRUCTION. STEEL IN PLACE AND SUPPORTED 3"ABOVE AND 3)NO WATER COURSE OR NATURAL DRAINAGE SHALL BE AWAY FROM THE SURROUNDING EARTH/DIRT. OBSTRUCTED. 2)REBAR/PR AR AND 4)GROUT ONLYTHE CELL q CONTAINING REBAR. THIS WALL VERTICAL RIEMANM�PLIMXMPRIOR TO IS NOT DESIGNED FOR ALL CELLS TO BE GROUTED. PLACING GRO1' = D NkXQ&AEM 5)ALL REBAR TO BE ASTM SPEC.A615,GRADE 40 MINIMUM. 3)Fes; PART 6)ALL REBAR LAP SPLICES TO BE 24"MINIMUM. DECORATIVE'PLANWROVAL 7)ALL MASONRY UNITS TO BE ASTM G90 GRADE N. 8)REBAR To BE CENTERED IN MASONRY CELLS. WESTERN Rrvzimsm COUNTY CODE UNIFORMITY PROGRAM *SEE PAGE 2 FOR ADDITIONAL INFORMATION* �kWWWWEWF.E ( DISCLAIMER: BUILDING DEPARTMENT ALTERNATE DESIGNS MAY BE POSSIBLE NIF WHEN PROVIDED WITH AN ENGINEERED ANALYSIS. USE OF THIS STANDARD DESIGN FREE'-4VMElgft4WPfiKnV466tru4dtl)belp IS AT THE USER'S RISK AND CARRIES NO 1pp-hrf S;Any"M61, F IMPLIED OR INFERRED GUARANTEE AGAINST (951)672-6777 29714rWA1b%y IFEE 1.C. ;586"mVhefederal FAILURE OR DEFECTS. —1 npahmnancLq �Pt nf" doansm I FAX(951)679-3843 I 2 y/2O14jjby;tm"jDMt�fMWEE.US I FArF I IF14 REBAR PLACEMENT ILLUSTRATION FOOTING OPTION B (TYPICAL) ALL REBAR SPLICES 2411 MIN. OVERLAP ........ . ....... ..... (TYPICAL) ONLY CELLS AND BOND BEAM COURSES WITH REBAR TO BE GROUTED (DO NOT SOLID GROUT ENTIRE WALL-USE GROUT STOP MESH AS APPROPRIATE) FOOTING OPTION A (TYPICAL) ALL REBAR SHALL HAVE A MINIMUM OF 311 CONCRETE COVER AT FOOTINGS DESIGN PA ETERS: wEsTEPN Rrimsitm coumTy com uNiFoRmrry PROGRAM SOIL tN I ACTIVE SOIL Pk)E§SUFtE`(PSlF) =30 oCITY OF MENIFEE PASSIVE SOIL BEARING(PSF) =150 BUILDING DEPARTMENT COEFFICIENT OF FRICTION =0.25 ALLOWABLE SOIL BEARING(PSF) =1500 1696 WIND=80 MPH;,E.'4FQOJLFRE C FREESTANDING BLOCK WALL SEISMIC: NA=1.3,NV=1.6,Z=0.4,SOIL PROFILE=SD 1 (951)672-6777 29714 HAUN ROAD,MENIFEE,CA 92586 1 FAx(951)679-3843 2/24/2014 1 WWW.ClTY0FMFNlFEE.US 1 PAGE20F2 TOP VIEW FOOTING BLOCK 27" GROUT STEEL REBAR --- IDe CL nifety e \ `> REBAR I I PLACEMENT 1== :=_- -_: dA 2 7 2016 U 2T' ILLUSTRATION W 0. do ived U SECTION VILL EW ::. '•'' " BLOCK (12"X 12"OR 16"X 16') I I I I SOLID GROUT '•III MIN.24" 6 6' i:. (4)-#4 REBAR REBAR MAX (ONEATEACHCORNEW OVERLAP -t _ ALL FOOTINGS ADJACENTTO I SLOPES TO BE AT LEAST 5'TO - ----- DAYLIGHT AS SHOWN BELOW. - "'- Q MIN 24" REBAR �•�� - _ iij OVERLAPSCO Qj GRADE Arn , QF _ BDF° 5'MIN. 4' — — FOOTING LIMITATIONS: FOOTNG REBNt SHaLL 1 PILASTER SPACING SHALL NOT EXCEED 20 FT.WHEN OTHER INFILL FENCING HaYEaMPi.6"IDNa 2n" HooKarroAMw. IS ATTACHED. 16" CONo COc OF3% 2.ONLY OPEN TYPE FENCING(SUCH AS WROUGHT IRON)MAY BE ATTACHED TO PILASTERS. SOLD TYPE FENCING MAY NOT BE ATTACHED TO PILASTER. 3.GATES AND DOORS ATTACHED TO PILASTER ARE LMTTED TO 200#MAX. WEIGHT AND 4 FT.MAX.WIDTH PER PILASTER. II� 4.THIS PILASTER DESIGN IS INTENDED TO BE USED ONLY AS A FENCING FEATURE AND IS NOT INTENDED TO SUPPORT ANY OTHER LOADS. 5.FENCE HEIGHTS ARE REGULATED—CONSULT ZONING REGULATIONS BEFORE CHECK WICH THE BUILDING DEPARTMENT BEGINNING CONSTRUCTION. nn C�LILL1�T TO VERIFY IF A BUILDING PERMIT IS REQUIRED, 6.INSTALLATION OF ELECTRIC CIRCUITS,CONDUITS,OR LGHTINGrIrEGNIS WHEN A BUILDING PERMIT IS REQUIRED, REQUIRE ELECTRICAL PERMITS AND INSPECTION. THE FOLLOWING INSPECTIONS ARE ALSO REQUIRED: 7•FOOTINGSTO BE PLACED IN UNDISTURBED SOIL OR PROPERLY COMPACTED 1)FOOTING;EXCAVATION TRENCH CLEAN WITH STEEL AND ENGINEERED FILL IN PLACE AND SUPPORTED 3"ABOVE AND AWAY FROM 8.FOR DESIGN PARAMETERS,SEE FREESTANDING BLOCK WALL STAND RD. THE SURROUNDING THE EARTH/DIRT. WESTERN RIVERSIDE COUNTY CODE UNIFORFLTY 2) REBAR/PRE-GROUT; VERTICAL REBAR IN PLACE- (:I'['y OF MENR INSPECTION PRIOR TO PLACING GROUT. IMIL DAT 3)FIB;AFTER GROUT IS PLACED-PRIOR TO ANY BUILDING DEPARTMENT DECORATIVE CAP PLACEMENT, NIF MASONRY PILASTE for,or an DISCLAIMER: a or city ALTERNATE DESIGNS MAYBE POSSIBLE WHEN PROVIDED WITH AN ENGINEERED ANALYSIS.USE OF THIS STANDARD DESIGN IS (951)672.6777 c� ll AT THE USER'S RISK AND CARRIES NO IMPUED OR INFERRED 29714 HAUN ROAD,MENIFEE,CA9tW1 on t GUARANTEE AGAINST FAILURE OR DEFECTS. FAX(95 U 679.3843 2/24/20I4 1 W W W,CTl1'OFMENIFEE.US PAGE t OF f