Loading...
PMT16-01500 City of Menifee Permit No.: PMT16-01500 _ I/!� 29714 HAUN RD. �CCE MENIFEE, CA 92586 Type: Residential Addition 9'ft.— MENIFEE Date Issued: 05I1212016 PERMIT Site Address: 27924 RIVERSHORE CT, MENIFEE, CA Parcel Number: 333-370-021 92585 Construction Cost: $1,200.00 Existing Use: 1 &2 Family Residence Proposed Use: Description of INSTALL 13'x 13'CITY STD LATTICE PATIO COVER ON FRONT OF HOUSE, NO ELECTRICAL Work: Owner Contractor CODY MAXWELL , 27924 RIVERSHORE COURT Applicant CODY MAXWELL License Number: 27924 RIVERSHORE COURT MENIFEE, CA Phone:9516793496 Fee Description 01b Amount fSl Building Permit Issuance 1 27.00 Deck/Patio, standard 1 83.00 GREEN FEE 1 1.00 SMIP RESIDENTIAL 1 1.00 General Plan Maintenance Fee-Building 1 4.15 $116.16 The issuance of this permit shall not prevent the building official from thereafter requiring the correction of enors in the plans and specifications or from preventing builiding operations being carried on thereunder when in violation of the Building Code or of any other ordinance of City of Menifee.Except as otherwise stated,a permit for construction under which no work is commenced within six months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be forfeited. AA_BIdg_Permit_Template.rpl Page 1 of 1 CITY OF MENIFEE LICENSED DECLARATION property who builds or improves thereon,and who contracts for the projects with a licensed contractor(s)pursuant to the Contractors State License Law). I hereby affirm under penalty of perjury that I am under provisions of Chapter9(commencing with section 7000)of Division 3 of the Business and I am exempt from I' nsure and #the ntracf rs State License Law for Professions Code and my license is in full force and effect. the following reason: License Class License No. By my signature below I a nowledge t ,except for my personal residence Expires Signature in which I must have resided for at least one year prior to completion of improvements covered by this permit.I cannot legally sell a structure that I WORKER'S COMPENSATION DECLARATION have built as an owner-builder if it has not been constructed in its entirety by in I hereby affirm under penalty of perjury one of the following declarations:I licensed contractors.I understand that a copy of the applicable law,Section have and will maintain a certificate of consent of self-insure for workers 7D44 of the Business and Professions Code,is available upon request when compensation,issued by the Director of Industrial Relations as provided for this application is submitted or at the following website: by Section 3700 of the Labor Code,for the performance of work for which wwwleginfo.ca.gav/calaw.html. this permit is issued. Policy# Date PROPERTY OWNER OR AUTHORIZED AGENT o I have and will maintain workers compensation insurance,as requited by section 3700 of the Labor Code,for the performance of the work for which ❑By my signature below I certify to each of the following:I am the property this permit is issued.My workers compensation insurance carrier and policy owner or authorized to act on the property owners behalf.I have read this number are: application and the information I have provided is correct.1 agree to comply with all applicable city and county ordinances and state laws relating to Carrier building construction.I authorize representatives of this city or county to Policy# Expires enter the above identified property for inspection purposes. (This section need not to be completed is the permit is for one-hundred Date dollars($100)or less PROPERTY OWNER OR AUTHORIZED AGENT ❑I certify that in the performance of the work for which this permit is issued, I shall not employ any persons in any manner so as to become subject to the CITY BUSINESS LICENSE# workers compensation laws of California,and agree that if I should become HAZARDOUS MATERIAL DECLARATION subject to the workers compensation provisions of Section 3700 of the Labor Code,I shall forthwith comply with those provisions. Will the applicant or future building occupant handle hazardous material or a mixture containing a hazardous material equal to or greater that the Applicant Date amounts specified on the Hazardous Materials Information Guide? WARNING:FAILURE TO SECURE WORKER'S COMPENSATION COVERAGE IS ❑Yes o No UNLAWFUL,AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES Will the Intended use of the building by the applicant or future building AND CIVIL FINES UP TOONE HUNDRED THOUSAND DOLLARS($100,000),IN occupant require a permit for the construction or modification from South ADDITION TO THE COST OF COMPENSATION,DAMAGES AS PROVIDED FOR Coast Air Quality Management District(SCAQMD)?See permitting checklist IN SECTION 3706 OF THE LABOR CODE,INTEREST,AND ATTORNEYS FEES for guidelines CONSTRUCTION LENDING AGENCY ❑Yes oNo I hereby affirm that under the penalty of perjury there is a construction Will the proposed building or modified facility be within 1000 feet of the lending agency for the performance of the work which this permit is issued outer boundary of a school? (Section 3097 Civil Code) ❑Yes in No OWNER BUILDER DECLARATIONS I have read the Hazardous Material Information Guide and the SCAQMD I hereby affirm Under penalty of perjury that I am exempt from the permitting checklist.I understand my requirements under the State of California Health&Safety Code,Section 25505 and 25534 concerning Contractors License Law for the reason(s)indicated below by the hazardous material reporting. checkmark(s)I have placed next to the applicable item(s)(Section 7031.5 Dyes in No Business and Professions Code).Any city or county that requires a permit to Date construct,alter,improve,demolish or repair any structure,prior to Its PROPERTY OWNER OR AUTHORIZED AGENT issuance,also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractors State EPA RENOVATION,REPAIR AND PAINTING(RRP) License Law(Chapter 9(commencing with Section 7000)of Division 3 of the The EPA Renovation,Repair and Painting(RRP)Rule requires contractors Business and Professions Code)or that he or she is exempt from licensure receiving compensation for most work that disturbs paint in a pre-1978 and the basis for the alleged exemption.Any violation of Section 7031.5 by residence or childcare facility to be RRP-certified firms and comply with an Applicant for a permit subjects the applicant to a civil penalty of not more required practices.This Includes rental property owners and property than($500). managers who do the paint-disturbing work themselves or through their �I,as owner of the property,or my employee with wages as their sole employees.For more information about EPA's Renovation Program visit: compensation,will doo all of or( I portion of the work,and the structure is www.epa.gov/lead or contact the National Lead Information Center at not intended or offered for sale.(Section 7044,Business and Professions 1-800-424-LEAD(5323). Code;The Contractors State License Law does not apply to an owner of a ❑An EPA Lead-Safe Certified Renovator will be responsible for this project property who,through employees'or personal effort,builds or improves the property provided that the improvements are not intended or offered for Certified Firm Name: sale.If,however,the building or improvement is sold within one year of Firm Certification No.: completion,the Owner-Builder will have the burden of proving that it was not built or improved for the purpose of sale. ❑No EPA Lead-Safe Certified Firm is required forthis project because: ❑I,as owner of the property am exclusively contracting with licensed contractors to construct the project(Section 7044,Business and Professions Code:The Contractors State License Law does not apply to an owner of a If your project does not comply with EPA RRP rule please fill out the RRP Acknowledgement. & SAFETY PERMIT/PLAN CHECK APPLICATION Menifee DATE — W- — PERMIT/PLAN CHECK NUMBER TYPE: O COMMERCIAL RESIDENTIAL O MULTI-FAMILY O MOBILE HOME O POOL/SPA O SIGN SUBTYPE: YADDITION O ALTERATION O DEMOLITION O ELECTRICAL O MECHANICAL O NEW O PLUMBING O RE-ROOF-NUMBER OF SQUARES DESCRIPTION OF WORK FrU,?J- kroo,q OIY3'L v e/-' 1a), 1 I a PROJECTADDRESS d- r� / Y"n FCA-WS ASSESSOR'S PARCEL NUMBER V• LOT TRACT C�Q-SlC/ OWNER NAME SA, I .,. G✓lo4 ADDRESS PHONE 9JI 1p7 EMAIL a.54rC/ 2 APPLICANT NAME Qp L4 =l, ADDRESS `1� 7- y✓l _/ �- - i/ PHONE �,�� ������� EMAIL CONTRACTOR'S NAME kjt> t (3t�jo <e OWNER BUILDER? ,,e YES O NO BUSINESS NAME ADDRESS PHONE EMAIL CONTRACTOR'S STATE LIC NUMBER LICENSE CLASSIFICATION VALUATION$ SO FT L SO FT APPLICANT'S SIGNATURE DATE -����1b DEPARTMENT DISTRIBUTION CITY OF MENIFEE BUSINESS LICENSE NUMBER BUILDING PLANNING ENGINEERING FIRE GREEN SMIP INVOICE PAID AMOUNT ' w ,G AMOUNT W OCASH 0CHECK# OCREDITCARD VISAIMC PLAN CHECK FEES PAIDAMOUNT OCASH OCHECK# 0CREDIT CARD VISA/MC OWNER BUILDER VERIFIED O YES O NO DL NUMBER NOTARIZED LETTER O YES O NO City of Menifee Building&Safety Deportment 29714 HDun Rd. Menifee, CA 92586 951-672-6777 www.cityofinenifee.us Inspection Request Line 951-246-6213 LtUI-Ith Ot I MAUR USOLIDBLOCWNGREOUIREDFOR 2 OR 0(429'O.Q MIN.SPACING ALL SOLID PATIO COVERS W/MIN 131 RAFEERSPACING: RCOFELOPE:'''A"P FOOTMINL LATTCEOR Vz"NOM19NALPLYWOOD EOGENAIL PLMOODW/N I Ed TOENAIISTO HEAOEA.OR h34 9EETgBLE•A• WRN BUILTLPORfiOLL ROOFlNG NNLSP8"O.C. ERE) OB"/ OR EpUAL FRAMINGANGLES 12"HMIING EL4EW11ERE) ' A p ' I SIMP.ANH2(OREOUAU - O EAOERSPAN*9� SIMPSON(OREOUAL) �24•• HURRICANECLIPS048"O.G 24'--*4 SEETABLE•B' : POSTCAPSOR I_Mq)< LEIXIM IEEE TABLE •G- G MAIL ' T'SIRAPEACHSIDE OVEBH OVERHANG I WUk THiN BOLTS FRAA'BiB DETAILS(PGZ w KNEEBRACE - OR IB,I ALS U CLEARANCE SEE FRAMING W-8"MIN. DETAILS MG.0 RAFTER SPAN h SIZE SEETABLE'A B'-O"MAK EXISTING WOOD --------------- STUD WALL TYPICAL COLT MNBASE-USE U. 4X4 POSTS SIMPSON CBEO.Pas ; _ 3'/:'CONCRETE OR EOwLw/BOLTS/ I, - ---- SLAB TWICAL MIN SCREW^/NAILS PER I' F SLOPE O "4 OST 4%4 POST , qsR ! o Bulldin & Safet I"STANDOFF BEICOO1.-------- 9 Y� pt. ONCRETEPNO WOOD POE FOOTNGS�: MAY 12 2016 I j gETABLE'C FRONT VIEW ---------------------------- SID VIEW TABLE "A" TABLE "BTT TABLE "C" TABLE ' ' RAFTER SPANS HEADER SIZE &SPANS FOOTING SIZE LEDGER (DOUGLAS FIR#2OR BETTER) (DOUGLAS FIR#2 OR BETTER) BOLTING SIZE SPACING SPAN BASED ON 1000 All LAG BOLTS RAFTER H DER P.S.F. SOIL BEARING SHALL HAVE 'A' SPAN SPAN SIZE PRESSURE. PRE-DRILLED HOLES-(SEE NOTE2) /S 2 x 4 1211 O.C. 9'-1 O" 8'-0"MAX 4 X 6 18" SQ.X 12" DEEP 16"O.C. 81- 1 1" UP TO 1 O'-0" MAX 4 x 8 16" SQ.X 12" DEEP X 5" i 3/8 3/8"" DI A. O.C. 24" O,C. 7'-8" 12'-0" 12'-0" MAX 4 x 10 18" SQ.X 12"DEEP LONSTAGGERED 32" O.C. *61-311 14'-0" MAX 4 x 12 18"SQ.X 12"DEEP 2 X 6 1211 O.C. 15'-4" 12'-111 8' " MAX 4 x 8 24"SQ.X 12"DEEP (2) 3/8" DIA X 5" 16" O.C. 13'-9" TO 10'-0"MAX 4 x 10 24"SQ.X 1211 DEEP LONG AT 16" 24" O.C. 1 V-3" 12'-0"MAX 4 x 12 2411 SQ.X 12" DEEP O.C. 32" O.C. *g'-7" 20'-0" 14'-O" MAX 4 x 14 24" SQ.X 121, DEEP 2x8 12'IO.C, 20'-0" NOTES: 16" O.C, 18'-2" 1 TWO 2X MEMBERS MAY BE SUBSTITUTED FOR ONE 4X HORIZONTAL 24"O.C. 141. 1 O" FRAMING MEMBER. 32" O.C. *12'.8" 2. LAG BOLTS MUST FULLY ENGAGE A WOOD STUD OR RIM JOIST AND BE 2 X 1 O 12"O.C. 20'-0" PROVIDED WITH APPROPRIATE WASHERS. LAG BOLTS SHALL BE LOCATED A 1 611 O.C. 20'-011 MINIMUM OF 1-1/2"FROM THE TOP OR BOTTOM OFTHE LEDGER. 2411O.C. 3. NOT DES IGNEDTOBE ENCLOSED-ADDMONALENGINEERING ANALYSIS WILL 32 O.C. 16'-2" BE REQUIRED IF ENCLOSED. 4 X 4 24"O.C. 1 O'-0" 4. SEE PAGE 2 OF 2 FOR CONSTRUCTION DETAILS. 32"O.C. *9'-3" B" O.C. *71-BIT_ DISCLAIMER: 4 X 6 24"O.C. 15'- 1 1" ALTERNATE PATIO DESIGNS MAY BE POSSIBLE WHEN PROVIDED WITH AN ENGINEERED ANALYSIS. USE OF THIS CONVENTIONAL STANDARD DESIGN IS 32" O.C. * 3'-9" AT THE USER'S RISK AND CARRIES NO IMPLIED OR INFERRED GUARANTEE AGAINST FAILURE OR DEFECTS. 4x8 " ETY DEPART wEarERN RIYERBIDE COUNTY CODE UNMRMrTY PROGRAM * 1 CITY OF MENIF'EE a THIS SPACING AND SPAN NIF BUILDING DEPARTMENT IS FOR LATTICE O _ _ R Y Q PATIO COVER STANDARD (95 77 29714 HAUN ROAD,MENIFEE.CA 92586 'Approval of these plans shall no:be ccnstl lied to be a 679-3843 2/24/2014 1 W W .CRVOFMENIFEEAS I PAGE]OFF approval of,any violation of any provisions of the federal,state or city regulations and ordinances. This set of approved plans must be kept on the KNEE BRACE DETAIL AT END POSTS LEDGERATTACHMENT (REQUIRED WHEN RAFTER SPAN EXCEEDS 12 FT.) DETAIL 2a•' 24 EXISTING ROOF D O —HEADFR MGENA O O PL DA 6L Y 3/B••X5• I0 O.C.ATIID M LAG F Vi DIABOLTS W/NIflS9 BOLTS n IS' 3" Wr\9HDiSTPICAL ALL a EXISTING BRACEDCONNECTIONS s uos 4x4 BRACE (212X4 BRACES RAFTER 4.4 , 3•• O APPROVED JOIST 2X LEDGER poB 4x4posT A A HANGER (MIN.) I SECTION A-A NHS: 1.USE A CONTINUOUS 2X LEDGER-SAME DEPTH AS RAFTER OR LARGER OPTION RrRcnJ OPTION2 2.SEETABLE"D'FOR BOLTING REQUIREMENTS INVERTED HEADER DESIGN OPTION (LATTICE ONLY) TWO 1/2"DIA.THRU-BOLTS o (W/WASHERS), PER CONNECTION AS SHOWN T o o o ,,. . FOR HEADERS OR RAFTERS- 0 TWO 2X MEMBERS MAY BE SUBSTITUTED FOR ONE 4X -�� N MEMBER. SEE TABLES "A" & S` "B FOR SPAN LIMITS NOTE: KNEE BRACING REQUIRED ,. WHEN RAFTER SPAN EXCEEDS 12 FEET 2X FASCIA(OVERHANG)ATTACHMENT- LATTICE ONLY OPTION I OPTION 2 _ 2X4 RAFTERS OR PRE-FAB.RODFTRUSSES 2X4 LEDGER W/20d NAILS OR-A"DIA.X 4" 2 6OR LARGER RAFTERS LONG LAG BOLTS @32"O.C. 2%a STRUT W/(3)Etl TOENAILS SIMPSON A-350R FROM STRUT TO LEDGER -----I EQUALANCHOR e �A-390R1 EQUAL ANCHOR \� IVI 2X FASCIA 2X FASCIA ICI APPROVED JOIST HANGER APPROVED JOIST HANGER 2X2 OR 2X4 � \ PATIO RAFTERS PATIO RAFTERS Ae—SEETABLE W A SEETABLE'A" III 30"MAX -II PA'nO R,AFTERSPAN PATIO RAFTERSPAN I_ OVERHANG 'I_"^"'�-"•`"g7OR LATRCE ••MAX -UMREDTO B'FOR LA777CE COVER OVERHANG-►1I COVFR- WE6CQiN R&;ERBIDE COUNTY CODE EUNIVIDII ITV PMMRAM NOTE: VERIFY STRUCTURAL SOUNDNESS OF ROOF CITY OFj4is 1 11IFEE RAFTERS FOR DECAY OR TERMITE DAMAGE, BUILDING DEPARTMENT AND REPLACE WITH LIKE MATERIALS AS NIF NEEDED, AFTER CONSULTATION WITH THE PATIO COV�T Rr §TT •e I JDARD BUILDING DEPARTMENT. fT '.kitl'� (95'15 672-6777 29714 HAUN ROAD,MENIFEE,CA 92586 FAX(95U 67.9.3843; yea/2ola I www.c .us PAGE20F2 LEDG R & TRACK \` INSPEC ION REQUIRED p I W o sILL 9 City of Menifoe . a � p` Building & Safety Dept. MAY 12 2016 14-1 Received � I CITY OF MENIFEE 4} BUILDING AND SAFETY DEPARTMENT_ 40 r L PLAN APPROVAL .9 REVIEWED BY DATE - 'Approval of these plans shall nut be construed to be a permit for,or an �J approval of,any violation of any prov(sions of the federal,state or city C regulations and ordinances. This set of approved plans must be kept on the jobsite until completion. C \