Loading...
PMT16-01270 City of Menifee Permit No.: PMT16-01270 29714 HAUN RD. Type: Residential Electrical �ACCELA---?' MENIFEE, CA 92586 MENIFEE Date Issued: 04127/2016 PERMIT Site Address: 29171 ABELIA GLEN ST, MENIFEE, CA Parcel Number: 333-640-019 92584 Construction Cost: $8,017.20 Existing Use: Proposed Use: Description of SOLAR TR 31582-1 MENIFEE HILLS Work: 12 MODULES, 3.18KW LOT 105 Owner Contractor LENNAR HOMES OF CA LENNAR HOMES OF CALIFORNIA INC 980 MONTECITO DR#302 25 ENTERPRISE CORONA, CA 92879 ALISO VIEJO, CA 92656 Applicant Phone: 9493498269 JEREMIAH ACAYTURRI License Number:728102 LENNAR HOMES OF CALIFORNIA INC 25 ENTERPRISE ALISO VIEJO, CA 92656 Fee Description ,ON Amount($ Solar, Residential or Small Commercial 1 252.00 Building Permit Issuance 1 27.00 GREEN FEE 1 1.00 SMIP RESIDENTIAL 1 2.00 General Plan Maintenance Fee-Electrical 1 12.60 $294.60 The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and specifications or from preventing builiding operations being carried on thereunder when in violation of the Building Code or of any other ordinance of City of Menifee.Except as otherwise stated,a permit for construction under which no work is commenced within six months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be forfeited. AA_Bldg Permit_Template.rpt Page 1 of 1 CITY OF MENIFEE LICENSED DECLARATION property who builds or improves thereon,and who contracts for the projects I hereby affirm under penalty of perjury that I am under provisions of with a licensed contractor(s)pursuant to the Contractors State License Law). Chapter9(commencing with section 7000)of Division 3 of the Business and ❑I am exempt from licensure under the Contractor's State License Law for Professions Code and my license is in full force and effect. the following reason: License Class License No. By my signature below I acknowledge that,except for my personal residence Expires Signature in which I must have resided for at least one year prior to completion of improvements covered by this permit.I cannot legally sell a structure that I WORKER'S COMPENSATION DECLARATION have built as an owner-builder if it has not been constructed in its entirety by ❑I hereby affirm under penalty of perjury one of the following declarations:I licensed contractors.I understand that a copy of the applicable law,Section have and will maintain a certificate of consent of self-insure for worker's 7044 of the Business and Professions Code,is available upon request when compensation,issued by the Director of Industrial Relations as provided for this application is submitted or at the following website: by Section 3700 of the Labor Code,for the performance of work for which www.IeRinfo.ca.Rov/caIaw.htm1.permit is issued. Policy# Date ❑I have and will maintain worker's compensation insurance,as required by PROPERTY OWNER OR AUTHORIZED AGENT section 3700 of the Labor code,for the performance of the work for which ❑By my signature below I certify to each of the following:I am the property this permit is issued.My worker's compensation insurance carrier and policy owner or authorized to act on the property owner's behalf.I have read this number are: application and the Information I have provided is correct.I agree to comply Cartier with all applicable city and county ordinances and state laws relating to building construction.I authorize representatives of this city or county to Policy# Expires enter the above identified property for inspection purposes. (This section need not to be completed is the permit is for one-hundred Date dollars($100)or less PROPERTY OWNER OR AUTHORIZED AGENT ❑I certify that in the performance of the work for which this permit is issued, I shall not emoloV any persons in any manner so as to become subject to the CITY BUSINESS LICENSE# worker's compensation laws of California,and agree that if I should become HAZARDOUS MATERIAL DECLARATION subject to the worker's compensation provisions of Section 3700 of the Labor Code,I shall forthwith comply with those provisions. Will the applicant or future building occupant handle hazardous material or a Applicant Date mixture containing a hazardous material equal to or greater that the amounts specified on the Hazardous Materials Information Guide? WARNING:FAILURE TO SECURE WORKER'S COMPENSATION COVERAGE IS ❑Yes ❑No UNLAWFUL,AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES Will the intended use of the building by the applicant or future building AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS($100,000),IN occupant require a permit for the construction or modification from South ADDITION TO THE COST OF COMPENSATION,DAMAGES AS PROVIDED FOR Coast Air Quality Management District(SCAQMD)?See permitting checklist IN SECTION 3706 OF THE LABOR CODE,INTEREST,AND ATTORNEYS FEES forguidelines CONSTRUCTION LENDING AGENCY ❑Yes ❑No I hereby affirm that under the penalty of perjury there is a construction Will the proposed building or modified facility be within 1000 feet of the lending agency for the performance of the work which this permit is issued outer boundary of a school? (Section 3097 Civil Code) ❑Yes ❑No OWNER BUILDER DECLARATIONS I have read the Hazardous Material Information Guide and the SCAQMD permitting checklist I understand my requirements under the State of I hereby affirm under penalty of perjury that I am exempt from the Contractor's License Law for the reason(s)indicated below by the hazardous Health al Safety Code,Section 25505 and 25534 concerning hazardous material reporting. checkmark(s)I have placed next to the applicable Rem(s)(Section 7031.5 oyes ❑No Business and Professions Code).Any city or county that requires a permit to Date construct,alter,improve,demolish or repair any structure,prior to its PROPERTY OWNER OR AUTHORIZED AGENT issuance,also requires the applicant for the permit to file a signed statement that he or she Is licensed pursuant to the provisions of the Contractor's State EPA RENOVATION,REPAIR AND PAINTING IRRPI License Law(Chapter 9(commencing with Section 7000)of Division 3 of the The EPA Renovation,Repair and Painting(RRP)Rule requires contractors Business and Professions code)or that he or she is exempt from licensure receiving compensation for most work that disturbs paint in a pre-1978 and the basis for the alleged exemption.Any violation of Section 7031.5 by residence or childcare facility to be RRP-certified firms and comply with an Applicant for a permit subjects the applicant to a civil penalty of not more required practices.This includes rental property owners and property than($500). managers who do the paint-disturbing work themselves or through their ❑I,as owner of the property,or my employee with wages as their sole employees.For more information about EPA's Renovation Program visit: compensation,will do( )all of or( )portion of the work,and the structure is www.eoa.eov/lead or contact the National Lead Information Center at not intended or offered for sale.(Section 7044,Business and Professions 1-800-424-LEAD(5323). Code;The Contractor's State License Law does not apply to an owner of a ❑An EPA Lead-Safe Certified Renovator will be responsible for this project property who,through employees'or personal effort,builds or improves the property provided that the improvements are not intended or offered for Certified Firm Name: sale.If,however,the building or improvement is sold within one year of Firm Certification No.: completion,the Owner-Builder will have the burden of proving that It was not built or improved for the purpose of sale. ❑No EPA Lead-Safe Certified Fro is required for this project because: ❑I,as owner of the property am exclusively contracting with licensed contractors to construct the project(Section 7044,Business and Professions Code:The Contractor's State License Law does not apply to an owner of a If your Project does not comply with EPA RRP rule please fill out the RRP Acknowledgement. r ,4 BUILDING & SAFETY PERMIT/PLAN CHECK APPLICATION w Menifee DATE 0 410 5/2 0 1 6 PERMIT/PLAN CHECK NUMBER TYPE: [—]COMMERCIAL ❑✓ RESIDENTIAL MULTI-FAMILY ❑MOBILEHOME ❑POOL/SPA ❑SIGN SUBTYPE: ❑✓ ADDITION []ALTERATION [—]DEMOLITION ❑ELEcfRICAL []MECHANICAL [—]NEW [—]PLUMBING [:IRE-ROOF-NUMBEROFSQUARES DESCRIPTION OF WORK Solar Permit-Plan 2686-3.18Kw/12PCS Master Solar Plan Permit No.: PMT14-00706 PROJECT ADDRESS 29171 Abelia Glen St, Men'Ifee CA 92584 ASSESSOR'S PARCEL NUMBER 333-640-019 LOT 105 TRACT 31582-1 PROPERTY OWNER'S NAME Lennar Homes of California, Inc. ADDRESS 980 Montecito Dr.,Suite 302, Corona,CA 92879 PHONE (951)817-3680 EMAIL leremiah.acayturri@lennar.com APPLICANT NAME Lennar Homes of California, Inc. ADDRESS 980 Montecito Dr.,Suite 302,Corona, CA 92879 PHONE (951)817-3680 EMAIL leremiah.acayturri@lennar.com CONTRACTOR'S NAME Lennar Homes of California, Inc. OWNER BUILDER? ❑✓ YES❑NO BUSINESS NAME Lennar Homes of California, Inc. ADDRESS 980 Montecito Dr.,Suite 302,Corona,CA 92879 PHONE (951)817-3680 EMAIL leremiah.acayturri@lenanr.com CONTRACTOR'S STATE LIC NUMBER 728102 LICENSE CLASSIFICATION A&B VALUATION$ $8,017.20 APPLICANT'S SIGNATURE DATE 04/05/2016 • r j, DEPARTMENT DISTRIBUTION I 11 CITY OF MENIFEE BUSINESS LICENSE NUMBER BUILDING PLANNING ENGINEERING FIRE GREEN SMIP Y� INVOICE7pAID AMOUNT `O AMOUNT 1 • CASH OCHECK# � CREDITCARD VISA/MC PLAN CHECK FEES PAIDAMOUNT OCASH 0CHECK II 'OCREDITCARD VISA/MC OWNER BUILDER VERIFIED O YES 0 NO DL NUMBER NOTARIZED LETTER O YES O NO City of Menifee Building&Safety Department 29714 Haun Rd. Menifee, CA 92586 951-672-6777 www.cityofinenifee.us Inspection Request Line 951-246-6213 SYSTEM INFORMATION BUYER ACKNOWLEDGES THAT THE SOLAR MODULES TO BE INSTALLED ITEM I QTY MFR. MODEL ON THE ROOF OF THE HOME WILL BE SUBSTANTIALLY IN THE SYSTEM SIZE 3.12 KW LOCATIONS INDICATED BY THE ILLUSTRATION. MODULE 12 PCS. HYUNDAI HIS-S265RG(265W) BUYER: INVERTER 1 12 PCS.1 ENPHASE I M215-60-2LL-S22-IG ROOF TYPE I TILE W/COMPOSITE SHINGLE UNDER ARRAY City of Menifee DATE: SUB-ARRAY INFORMATION Building Dept ARRAY#I ARRAY#2 ARRAY#3 CITY OF MENIFEE MOD QTY 12 BUYER: NA NA APR 2 `2 60' BUILDING AND SAFETY TILT 23° NA' NA' DATE: AZIMUTH 224° 1 NA' NV Received PLAN APPROVAL REVIEWED BY� 3'-0• 10, 10' *Approval of these plans shall not be cor F approval of,any violation of any provisio I P _ regulations and ordinances. This set of a I jobsite until completion. I I u aw I I ao I I I i r I / I I v I I SOLADECK WIRE TRANSITION BOX i (UNDER ARRAY) I I • .� 1 l I I I I P AC DISCONNECT A EXTERIOR-GARAGE UTILITY METER B MAIN SERVICE PANEL (VERIFIED BY BUILDER) L 0d) I L tom,• NOTE:DIMENSIONS ARE SHOWN IN PLANE OF ROOF PLAN 2686 ELEVATION A ORIENTATION 3 LO #75 05 LENNAR: ORIGINAL BY: JIM PARKS DATE:15.11.20 MENIFEE HILLS 980 MONTECITO DRIVE,#302 REVIEWED BY:TOM FIDDES I DATE:15.11.23 R CORONA,CA 92079 REV.# BY DATE DESCRIPTION namaste SOLAR DWG TITLE: PAGE#: SCALE: SITE LOCATION: 4571 Broadway SVeel INDIVIDUAL 29171 ABELIA GLEN STREET Boulder,CO 003114 PLOT PLAN 1116'=P-O' MENIFEE,CA 303.447.030D SYSTEM LAYOUT MODULE SPECS AND CALCULATIONS INVERTER SPECS AND CALCULATIONS ITEM NOTE/CALC UNIT DETAIL ITEM NOTE/CALC UNIT DETAIL LOCATION MENIFEE.CA INV. MAKE INVERTER SPEC ENPHASE TEMP,AMBIENT HIGH(TMAX) ASHRAE 2% °C 37 INV. MODEL INVERTER SPEC M215-60-2LL-S22-IG TEMP,AMBIENT LOW(THIN) ASHRAE EXTR.MIN °C -2 INV. MAX POWER,(WAc MAX) INVERTER SPEC WATTS(AC) 225 TEMP,MODULE TEST(TTSST) MODULE SPEC °C 25 INV. INPUT V.(VDD MAX) INVERTER SPEC VOLTS(00 48 TEMP,DELTA LOW(TDELTA) TMIN-TTEST °C -27 INV. OUTPUT V,(VAc NOM) INVERTER SPEC VOLTS(AO) 240 MOD.MANUFACTURER MODULE SPEC HYUNDAI INV. OUTPUT FREQUENCY INVERTER SPEC HERTZ 60 MOD. PART NUMBER MODULE SPEC HIS-S265RG INV. OUTPUT CURRENT, IAc INVERTER SPEC AMPS(AC) 0.9 MOD. POWER STC(P) MODULE SPEC WATTS(DC) 265 INV. PHASE QUANTITY INVERTER SPEC PHASE I MOD. POWER PTC MODULE SPEC WATTS(cc) 238 COMPLIANCE INVERTER SPEC ULI741A EE1547 MOD. OPERATING VOLTAGE(VMP) MODULE SPEC VOLTS(DC) 3L30 INV. GROUNDING INVERTER SPEC ISOLATED MOD. OPEN CCT.VOLTAGE(Voc) MODULE SPEC VOLTS(DC) 38.10 INV. QTY.MAX/BRANCH CCT. INV.QTYBc OTY 112 MOD, COEFF. VOLT/TEMP(COEF) MODULE SPEC V/°C -0.114 BRANCH CCT.OUTPUT, INIAXBC (IAC•INV.QTYBU AMPS(AC) 10.80 M MAX VOLTAGE(VNAXMOD) (Vac a(TD*CDEF)) VOLTS(DO 41.18 INV. QUANTITY,TOTAL INV.QTYT QTV 12 TING CURRENT(Imp) MODULE SPEC AMPS(DC) 8.50 TOTAL SYSTEM OUTPUT, Inaxis (lac•INV.QTYT) AMPS(Ac) IO.BO 0 HOT CCT.CURRENT OSC) MODULE SPEC AMPS(DC) 9.00 p, 0 MAXIMUM CURRENT(IMAX) (ISE• 1.25) AMPS(DC) 11.25 IN.AMPACITY REO'D,PER NEC (IMAX• 1.25) AMPS(DC) 14.06 SERIES FUSE RATING,MAX MODULE SPEC AMPS(DC) 15 ELECTRICAL EQUIPMENT SCHEDULE KEY OTY I MANUFACTURER MODEL NOTES TRADE 1 12 HYUNDAI HIS-S265RG (265W) PV MODULE SOLAR 2 12 ENPHASE M215-60-2LL-S22-IG PV INVERTER SOLAR 3 1 RSTC/SOLADECK 0786-3R5 PV ROOF JUNCTION BOX,NEMA 3R SOLAR 4 1 CUTLER-HAMMER DG221LIRB PV AC DISCONNECT, NEMA 3R.24OV,30A SOLAR 5 1 ENPHASE ENVOY PV DATA MONITOR, 120V SOLAR 6 1 TBD TBD 120V DEDICATED RECEPTACLE FOR ENVOY PV DATA MONITOR SOLAR 7 1 TBD TBD CAT5 PORT FOR SOLAR PV INTERNET CONNECTION TO HOME NETWORK BOX SOLAR 8 NOTE CUTLER-HAMMER TBD PV BRANCH CIRCUIT BREAKERS: I X 15A-IP(ENVOY) SOLAR 9 NOTE CUTLER-HAMMER TBD PV BREAKER, I X 2OA-2P,LOCATE AT OPPOSITE END OF BUS FROM MAIN BREAKER SOLAR 10 1.00 TBD I TBD SERVICE PANEL,MIN. 125A BUS BLDR. ELEC. 11 I TBD TBD UTILITY METER, IPH,120/24OV,200A BLDR. ELEC. 12 11 A I TBD I TBD I GROUNDING ELECTRODE UFER BLDR. ELEC. 0.04 UbIR rICTOR SIZING CALCULATIONS INTERCONNECTION CALCULATIONS I)QONDIVON OF USE(COU): I (AMPACITY• TEMP. DEBATE • FILL DERATE) VS. REO'D(IMAX) ITEM UNIT PANEL 2) ALS(TERM): I AMPACITY AT TERMINALS. VS. REG'D,(IMAX• 1.25) PANEL MFR. p CUTLER-HAMMER KEY I SIZE CU/AL INSULATION CALC. I AMPACITY W/O TEMP. FILL RESULT REQ'D OCD BUS RATING AMPS 200 TYPE DERATES DERATE DERATE (A) (A) USED(A) MAIN DISCONNECT AMPS 200 A 2 CU THWN-2 COU 30 0.76 1.0 22.80 10.80 ALLOWED PV PER NEC AMPS 40 TERM 25 25 13.50 20 PV OCPD DEVICE USED AMPS 20 B 0 CU NM-B COU 40 0.91 1.0 36.40 10.80 TERM 35 35 13.50 20 C qmkdO CU I NM-B COU 40 0.91 1.0 36.40 10.80 TERM 35 35 13.50 20 CG®"CTOR SCHEDULE KE NDUCTORB i CU/AL TYPE LOCATION TRADE A 12 ENGAGE CABLE, I-#6G,FREE AIR CU TC-ER ARRAY SOLAR 1-#10 EGC I CU NM-B(ROMEX) I NTERIOR I SOLAR C -#10, I-#10 EGC Cu NM-B(ROMEX) INTERIOR SOLAR 5 © II D ATSE,ETHERNET CABLE CU CATSE INTERIOR SOLAR O e o SEE NOTE 15 10 .�.. ISA/IP O 2 9 O O O 20A/2P 3 'N G G G� A B +10 I I I ROOF EXTERIOR-GARAGE ELECTRICAL DIAGRAM 3.18 KW LOT# 105 LENNAR: ORIGINAL BY: JIM PARKS DATE:15.11.20 MENIFEE HILLS 980 MONTECITO DRIVE,#302 REVIEWED BY:TOM FIDDES DATE:15.11.23 CORONA, CA 92879 REV.# BY DATE DESCRIPTION Ala namaste DWG TITLE: T AGE#: SCALE: SOLAR SITE LOCATION: 4571 Broadway Street INDIVIDUAL 29171 ABELIA GLEN STREET Boulder,CO 80304 PLOT PLAN 2 NTS ELECTRICAL MENIFEE,CA 303.447.0300 STRUCTURAL NOTES: SOLAR CONTRACTOR- 1)ALL PV ROOF ATTACHMENTS WILL BE SPACED ALONG MODULE RACKING RAILS AT NOT GREATER THAN 48'O.C. 2)ALL PV ROOF ATTACHMENTS WILL BE STAGGERED BY ROW AMONGST THE ROOF FRAMING MEMBERS,TO MAXIMUM EXTENT POSSIBLE. 3)ROOF PENETRATIONS ASSOCIATED WITH SOLAR RACKING WILL BE SEALED WITH AN APPROVED SEALANT. 4)SOLADECK WIRE TRANSITION BOX WILL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS. IT WILL BE FLASHED AND SEALED. 5)PV ARRAY WILL BE A MINIMUM OF 3'ABOVE THE COMPOSITE SHINGLE ROOF SURFACE. 6)THE UNIRAC SOLARMOUNT RACKING SYSTEM AND SOLAR PV ARRAY WILL BE INSTALLED ACCORDING TO THE UNIRAC SOLARMOUNT CODE-COMPLIANT INSTALLATION MANUAL,VERSION 227.3.PUB 140113-ICC,JANUARY 2014. 7)UNIRAC TOP CLAMPS REQUIRE A ONE INCH(I-)SPACE BETWEEN PV MODULES. SOLARMOUNT RAILS MUST EXTEND A MINIMUM OF TWO INCHES(2')BEYOND THE EDGE OF THE PV ARRAY I SUB-ARRAY. 8)UNIRAC SOLARMOUNT REQUIRES THAT A THERMAL EXPANSION GAP BE INSTALLED FOR ANY RAIL LENGTH OF GREATER THAN 40'. )EpARTM ENT ROOFING CONTRACTOR- U DISTANCE BETWEEN ARRAY EDGE AND TRANSITION FLASHING(COMPOSITION TO TILE)WILL BE A MINIMUM OF 3-. 2)26 GAUGE INTERLOCKING FLASHING 'SIDEWALL'TO BE INSTALLED ALONG THE LENGTH OF THE PV ARRAY AT ROOFING MATERIAL TRANSITION. IT SHALL BE APROVED PRIOR TO PV SYSTEM INSTALLATION. 3)PEEL-N-STICK BASE TO BE INSTALLED ONE FOOT W)OR MORE BEYOND THE EDGE OF THE COMPOSITION SHINGLE,DOWN TO THE ROOF EAVE. PE L K SE No BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS. 6 4)AREAS UNDER EACH PV ARRAY SHALL BE ROOFED WITH COMPOSITION SHINGLE. COMPOSITION SHINGLE SHALL RUN FROM ABOVE THE PV ARRAY E5)TILE 6)BIRDSTOP WILED HE LOW THE ARRAY O INSTALLED AT THE UPPERMOST TRANSITION FROM TILE BE INSTALLED ABOVE THE ITO COMPOSITION SHINGLETION ROOF PER ROOFER . BIRDSTOP TO BE SPECIFIED BY ROOFER PRIOR TO DATE INSTALLATION. permit fir,or an.. ;ICelal,state or city Dlans must he kept on the ELECTRICAL NOTES: GENERAL- D ALL PV EQUIPMENT WILL BE TESTED AND LISTED FOR ITS USE BY A NATIONALLY RECOGNIZED TESTING LABORATORY(NRTL). 2)THE GROUNDING OF THE PHOTOVOLTAIC SYSTEM SHALL COMPLY WITH THE APPLICABLE VERSION OF THE NEC/CEC. 3)ALL GROUNDING ELECTRODE CONDUCTORS WILL BE INSTALLED IN A CONTINUOUS LENGTH EXCEPT WHERE SPLICED BY AN IRREVERSIBLE CONNECTOR OR EXOTHERMIC WELD. 4)NON-CURRENT CARRYING METAL PARTS SHALL BE CHECKED FOR PROPER GROUNDING.NOTING THAT TERMINAL LUGS BOLTED ON AN ENCLOSURE'S FINISHED SURFACE MAY BE ELECTRICALLY INSULATED BECAUSE OF PAINT/FINISH. PAINT/FINISH AT POINT OF CONTACT SHALL BE PROPERLY REMOVED. 5)ROOF PENETRATIONS WILL BE COMPLETED AND SEALED PER APPLICABLE CODE. 6)ALL CONDUCTORS WILL HAVE A 90°C RATING TO ENSURE CODE COMPLIANCE, SOLAR CONTRACTOR- 7)MODULE CERTIFICATIONS WILL INCLUDE UL1703, IEC61646,IEC61730. 8)CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS. 9)RACEWAY POINT OF PENETRATION FROM EXTERIOR TO INTERIOR WILL BE SEALED TO PREVENT INGRESS OF WATER AND INSECTS. 10)DC WIRING IS LIMITED TO PV ARRAY FOOTPRINT W/ENPHASE MICRO-INVERTER SYSTEM. IU MODULE AND ENPHASE WIRING SHALL BE LOCATED AND SECURED UNDER THE ARRAY USING SUITABLE WIRING CLIPS. WIRING SHALL NOT MAKE CONTACT WITH THE ROOF SURFACE AND SHALL BE MANAGED IN A WORKMAN-LIKE MANNER. 12)EQUIPMENT GROUNDING CONDUCTORS WILL BE SIZED IN ACCORDANCE WITH NEC TABLE 250.122. 13)CONDUCTOR TERMINATIONS WILL BE TORQUED PER DEVICE LISTING,OR MANUFACTURER'S RECOMMENDATIONS. 14)A PV AGGREGATION PANEL(SUB PANEL)WILL NOT BE INCLUDED FOR SYSTEMS WITH ONE BRANCH CIRCUIT. 15)A DEDICATED 120V BRANCH CIRCUIT IS REQUIRED IN MASTER CLOSET(OR EQUIVALENT)FOR ENPHASE ENVOY MONITOR. SIGNAGE- 16)PV SYSTEMS SHALL BE CLEARLY MARKED IN ACCORDANCE WITH NEC ARTICLE 690 AND OTHER APPLICABLE STATE AND LOCAL CODES. 17)ALL SAFETY MARKING/PLACARDS SHALL BE PERMANENTLY ATTACHED BY ADHESIVE OR OTHER MECHANICAL MEANS. 18)MARKING/PLACARDS WILL BE METAL OR PLASTIC WITH ENGRAVED OR MACHINE PRINTED LETTERING. BACKGROUND WILL BE RED WITH WHITE CAPITAL LETTERING OF MINIMUM HEIGHT t. 19)ALL WIRING/RACEWAYS/JUNCTION BOXES WILL BE MARKED-PHOTOVOLTAIC POWER SOURCE;OR EQUIVALENT;WIRING/RACEWAYS SHALL BE MARKED EVERY 10'. BUILDER ELECTRICAL AND SOLAR CONTRACTORS- 20)INSTALLATION SHALL BE COMPLETED IN A NEAT AND WORKMAN-LIKE MANNER. 21)SPACE REQUIREMENTS FOR ALL ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110.26, ORIGINAL BY: JIM PARKS DATE:15.11.20 LENNAR: MENIFEE HILLS REVIEWED BY: TOM FIDDES DATE:15.1123 980 MONTECITO DRIVE,#302 CORONA,CA 92879 REV.# BY DATE DESCRIPTION to namast:6 DWG TITLE: PAGE#: SCALE: SITE LOCATION: 4571 B,eaadway Stmel INDIVIDUAL 29171 ABELIA GLEN STREET Boulder,C060304 PLOT PLAN 3 NTS MENIFEE.CA 303.447.0300 NOTES CAUTION: POWER TO THIS BUILDING IS SUPPLIED BY THE UTILITY AND A SOLAR PV SYSTEM. DISCONNECTS ARE LOCATED AS SHOWN. 43 SOLADECK WIRE TRANSITION BOX (UNDER ARRAY) PV AC DISCONNECT EXTERIOR-GARAGE UTILITY METER 8 MAIN SERVICE PANEL (VERIFIED BY BUILDER) SERVICE BY QUALIFIED PERSONNEL ONLY CONTACT: SUNSTREET ENERGY GROUP 1-877-SLR-POWR PV POWER SOURCE - AC SPECS AC OPERATING VOLTAGE: 240 V AC OPERATING CURRENT: 10.8 A NOTE: SEE MASTER SET FOR ADDITIONAL PLACARD INFORMATION LENNAR: ORIGINAL BY: JIM PARKS DATE:I5.II.20 MENIFEE HILLS 9BO MONTECITO DRIVE.#302 REVIEWED BY:TOM FIDDES DATE:I5.11.23 CORONA,CA 92879 REV.# BY DATE DESCRIPTION •, ID namasbe SOLAR DWG TITLE: PAGE#: I SCALE: SITE LOCATION: 4571 Broadway Stmel INDIVIDUAL 29171 ABELIA GLEN STREET Boulder,CO 80304 PLOT PLAN 4 NTS PLACARDS MENIFEE,CA 303.447.0300