PMT16-01228 City of Menifee Permit No.: PMT16-01228 29714 HAUN RD. �f-\CCELA—? MENIFEE,CA 92586 Type: Residential Addition MENIFEE Date Issued: 06/15/2016 PERMIT Site Address: 28363 CIDER ST,MENIFEE,CA 92585 Parcel Number: 329-381-010 Construction Cost: $832.00 Existing use: 1 &2 Family Residence Proposed use: Description of WALL TR 29495-7 JASPER PLACE Work: 6'X 16 L FT LOT 26 Owner Contractor FH 11, LLC FH II HOMEBUILDERS INC 8300 UTICA AVE#300 8300 UTICA AVENUE 300 RANCHO CUCAMONGA, CA 91730 RANCHO CUCAMONGA, CA 91730 Applicant Phone:9093548000 HEATHER ALVAREZ License Number:985D46 FH II HOMEBUILDERS INC 8300 UTICA AVENUE 300 RANCHO CUCAMONGA, CA 91730 Fee Description gqt Amount(SI Building Permit Issuance 1 27.00 Wall/Fence,standard 1 83.00 GREEN FEE 1 1.00 SMIP RESIDENTIAL 1 1.00 General Plan Maintenance Fee-Building 1 4.15 $116.15 The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and specifications or from preventing builiding operations being carded on thereunder when in violation of the Building Code or of any other ordinance of City of Menifee.Except as otherwise stated,a permit for construction under which no work is commenced within six months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be forfeited. AA_BIdLPennit_Template.rpt Page 1 of 1 CITY OF MENIFEE LICENSED DECLARATION property who builds or improves thereon,and who contracts for the projects I hereby affirm under penalty of perjury that I am under provisions of with a licensed contractor(s)pursuant to the Contractors State License Law). Chapter9(commencing with section 7000)of Division 3 of the Business and ❑I am exempt from licensure under the Contractor's State License Law for Professions Code and my license is in full force and effect. the following reason: License Class License No. By my signature below I acknowledge that,except for my personal residence Expires Signature in which I must have resided for at least one year prior to completion of WORKER'S COMPENSATION DECLARATION improvements covered by this permf.I cannot legally sell a structure that I have built as an owner-builder if it has not been constructed in its entirety by ❑I hereby affirm under penalty of perjury one of the following declarations:I licensed contractors.I understand that a copy of the applicable law,Section have and will maintain a certificate of consent of self-insure for worker's 7044 of the Business and Professions Code,is available upon request when compensation,issued by the Director of Industrial Relations as provided for this application is submitted or at the following website: by Section 3700 of the Labor Code,for the performance of work for which this permit is issued. www.leginfo.ca.gov/calaw.htmi. Policy# Date ❑I have and will maintain workers compensation insurance,as required by PROPERTY OWNER OR AUTHORIZED AGENT section 3700 of the Labor Code,for the performance of the work for which ❑By my signature below I certify to each of the following:I am the property this permit is issued.My workers compensation insurance carrier and policy owner or authorized to act on the property owners behalf.I have read this number are: application and the information I have provided is correct.I agree to comply Carrier with all applicable city and county ordinances and state laws relating to building construction.I authorize representatives of this city or county to Policy g Expires enter the above identified property for inspection purposes. (This section need not to be completed is the permit is for one-hundred Date dollars($100)or less PROPERTY OWNER OR AUTHORIZED AGENT ❑1 certify that in the performance of the work for which this permit is issued, I shall not employ any persons in any manner so as to become subject to the CITY BUSINESS LICENSE# workers compensation laws of California,and agree that if I should become HAZARDOUS MATERIAL DECLARATION subject to the workers compensation provisions of Section 3700 of the Labor Code,I shall forthwith comply with those provisions. Will the applicant or future building occupant handle hazardous material or a Applicant Date mixture containing a hazardous material equal to or greater that the amounts specified on the Hazardous Materials Information Guide.' WARNING:FAILURE TO SECURE WORKER'S COMPENSATION COVERAGE 15 ❑Yes ❑No UNLAWFUL,AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES Will the intended use of the building by the applicant or future building AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS($100,000),IN occupant require a permit for the construction or modification from South ADDITION TO THE COST OF COMPENSATION,DAMAGES AS PROVIDED FOR Coast Air Quality Management District(SCAQMD)7 See permitting checklist IN SECTION 3706 OF THE LABOR CODE,INTEREST,AND ATTORNEYS FEES forguidelines CONSTRUCTION LENDING AGENCY ❑Yes ❑No I hereby affirm that under the penalty of perjury there is a construction Will the proposed building or modified facility be within 1000 feet of the lending agency for the performance of the work which this permit is issued outer boundary of a school? (Section 3097 Civil Code) ❑Yes ❑No OWNER BUILDER DECLARATIONS I have read the Hazardous Material Information Guide and the SCAQMD I hereby affirm under penalty of perjury that tam exempt from the permitting checklist I understand my requirements under the State of Contractors License Law for the reason(s)indicated below by the California Health&Safety Code,Section 25505 and 25534 concerning hazardous material reporting. checkmark(s)I have placed next to the applicable item(s)(Section 7033-5 Dyes ❑No Business and Professions Code).Any city or county that requires a permit to Date construct,alter,improve,demolish or repair anystructure,prior to its PROPERTY OWNER OR AUTHORIZED AGENT issuance,also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractors State EPA RENOVATION.REPAIR AND PAINTING IRRPI License Law(Chapter 9(commencing with Section 7000)of Division 3 of the The EPA Renovation,Repair and Painting(RAP)Rule requires contractors Business and Professions Code)or that he or she Is exempt from licensure receiving compensation for most work that disturbs paint in a pre-1978 and the basis for the alleged exemption.Any violation of Section 7031.5 by residence or childcare facility to be RRP-certified firms and comply with an Applicant for a permit subjects the applicant to a civil penalty of not more required practices.This includes rental property owners and property than($500). managers who do the paint-disturbing work themselves or through their o 1,as owner of the property,or my employee with wages as their sole employees.For more information about EPA's Renovation Program visit: compensation,will do( )all of or( )portion of the work,and the structure is www.ena.eoy/lead or contact the National Lead Information Center at not intended or offered for sale.(Section 7044,Business and Professions 1-800-424-LEAD(5323). Code;The Contractors State License Law does not apply to an owner of a ❑An EPA Lead-Safe Certified Renovator will be responsible for this project property who,through employees'or personal effort,builds or improves the property provided that the improvements are not intended or offered for Certified Firm Name: sale.If,however,the building or improvement is sold within one year of Firm Certification No.: completion,the Owner-Builder will have the burden of proving that it was not built or improved for the purpose of sale. ❑No EPA Lead-Safe Certified Firm Is required forthis project because: D 1,as owner of the property am exclusively contracting with licensed contractors to construct the project(Section 7044,Business and Professions Code:The Contractors State License Law does not apply to an owner of a If your project does not comply with EPA RRP rule please fill out the RRP Acknowledgement. BUILDING & SAFETY PERMIT/PLAN CHECK APPLICATION y Menifee 1911�_Iwx�k DATE 04/06/2016 PERMIT/PLAN CHECK NUMBER ,�� TYPE: ❑COMMERCIAL ❑✓ RESIDENTIAL ❑MULTI-FAMILY ❑MOBILEHOME ❑POOL/SPA ❑SIGN SUBTYPE: ❑ADDITION []ALTERATION ❑DEMOLITION ❑ELECTRICAL ❑MECHANICAL ❑NEW []PLUMBING El RE-ROOF-NUMBER OF SQUARES DESCRIPTION OF WORK Block Wall Returns PROJECTADDRESS ASSESSOR'S PARCELNUMBER���,.]T�I� 01O LOT TRACT 29495-1 PROPERTY OWNER'S NAME FH II, LLC ADDRESS 8300 UTICA AVE,STE 300, RANCHO CUCAMONGA,CA 91730' PHONE (909)354-8000 EMAIL HALVAREZ@FRONTIER-ENTERPRISES.COM APPLICANT NAME HEATHER ALVAREZ ADDRESS 8300 UTICA AVE,STE 300, RANCHO CUCAMONGA,CA 91730 PHONE (909)354-8013 EMAIL HALVAREZ@FRONTIER-ENTERPRISES.COM CONTRACTOR'S NAME OWNERBUILDER? ❑✓ YES❑NO BUSINESS NAME ADDRESS PHONE EMAIL CONTRACTOR'S STATE LIC NUMBER 985046 LICENSE CLASSIFICATION `/B f VALUATION$ V2. 00 SOFT LSQFT -to I J� 1 lO1 APPLICANT'S SIGNATURE DATE 04/06/2016 CITY STAFF USE ONLY DEPARTMENT DISTRIBUTION I�NNI P CIN OF MENIFEE BUSINESS LICENSE NUMBER BUILDING PLA ENGIN RING FIRE GREEN SMI INVOICE 1 PAID AMOUNT AMOUNT OCASH OCHECK# OCREDIT CARD VISA/MC PLAN CHECK FEES PAIDAMOUNT 0CASH 0CHECK# OCREDITCARD VISA/MC OWNER BUILDER VERIFIED OYES O NO DL NUMBER NOTARIZED LETTER O YES O NO City of Menifee Building& Safety Department 29714 Houn Rd. rMemfee. CA 92586 951-572-6771 w;wir.cityofinenifee.us Inspection Request Line 951-246 521A FOOTING OPTION "A" Building Dept 9W"AMY EPA JUN 15 2016 PLAN !' #4 HORIZONTAL REBAR 0 D BEAM BLOC"' REV IL I! 6" OR B" BLOCK [IF L "H" *Apr;rojz )5 se plans shall'ffi be const 1 H OF FOOTING • #4 HORIZONTAL AT 32" MAX.O.C. tl= P EIGHT FROM TOP viola to oWw1ons (USE BOND BEAM BLOCK) re&dtftG i nances.-T1' SEE TABLE'W' SEETABLE"B" . I! b FOR REBAR SIZE FOR REBAR SIZEI"L< plet'on' AND SPACING ANDSPACING (LOCATE RE6 IN CE OF CELL) FINISH GRADE (1)-#4 REBAR CONTINUOUS T (2)-#4 REBAR ` MEOW 12 CONTINUOUS REVERSE DIRECTION OF W W 4 1H) HOOK ON EVERY (FOOTING �(FOOT NG WIDZ OTHER REBAR SEETABLE'A" SEETABLE"S" ALL FOOTINGS ADJACENT TO SLOPES TO BE AT LEAST UTO DAYLIGHT AS SHOWN BELOW. W" VERTICAL "H" "W" VERTICAL REINFORCEMENT REINFORCEMENT 3' 17" #4 Ca 48"O.C. 3' 191' #4 @ 48"O.C. 4' 20" #4 La 4811 O.C. 2 41 22" #4 @ 4811 O.C. 5' 23" #4 @ 4811 O.C. 5' 20" #4 @ 48"O.C. 6' 29" #4 La 24"O.C. so OF M 6' 34" #4 @ 24'O.C. FOOTING TNIN. NOTES: CHECK WITH.TH.E.BVILDINODEPARTM90-1 TO 1)THIS DESIGN DOES NOT ALLOW GRADE DIFFERENTIALS OF YERIFY IF ABU IMINQ FIE13049 15 REQUIRED. MORE THAN 6"ON OPPOSING SIDES OF THE WALL. THIS is WHEN A PERMIT IS REQUIRED,THE FOLLOWING NOT A RETAINING WALL. INSPECTIONS ARE REQUIRED: 2)FENCE HEIGHTS ARE REGULATED-CONSULT ZONING 1)FOOTIN-Q:EXCAVATION TRENCH CLEAN WITH REGULATIONS BEFORE BEGINNING CONSTRUCTION. STEEL IN PLACE AND SUPPORTED 311 ABOVE AND 3)NO WATER COURSE OR NATURAL DRAINAGE SHALL BE AWAY FROM THE SURROUNDING EARTH/DIRT. OBSTRUCTED. 2)RIE13AIMPRE-GROUT;BOND BEAM REBAR AND Jv 4)GROUT ONLY THE CELLS CONTAINING REBAR. THIS WALL VERTICAL REBAR IN PLACE-INSPECTION PRIOR TO IS NQT DESIGNED FOR ALL CELLS TO BE GROUTED. PLACING GROUT. 5)ALL REBAR TO BE ASTM SPEC.A615,GRADE 40 MINIMUM. 3)FINAL AFTER GROUT IS PLACED-PRIOR TO ANY 6)ALL REBAR LAP SPLICES TO BE 24"MINIMUM. DECORATIVE CAP PLACEMENT. 7)ALL MASONRY UNITS TO BE ASTM C-90 GRADE N. 8)REBAR TO BE CENTERED IN MASONRY CELLS. WESTERN RIVERSIDE COUNTY CODE UNIFORMITY PROGRAM *SEE PAGE 2 FOR ADDITIONAL INFORMATION' CITY OF MENIFEE DISCLAIMER BUILDING & SAFETY DIVISION ALTERNATE DESIGNS MAY BE POSSIBLE WHEN PROVIDED WITH AN ENGINEERED FREESTANDING BLOCK WALL ANALYSIS. USE OF THIS STANDARD DESIGN *s, IS AT THE USER'S RISK AND CARRIES NO 29714 HAUN ROAD IMPLIED OR INFERRED GUARANTEE AGAINST 951.672.6777 MENIFEE, CA 92586 FAILURE OR DEFECTS. R.E AR..PLACEMENT MENT ILLUSTRATION FOOTING-OPTION B DATE (TYPICAL or an ALL REBAR SPLICES state 2411 MIrq. ovERLAP — -- ------_-.._ . --- - — -.- - ._— — -- ---- --_ ro4the T. t lz 4 ti OWICAL) �• ONLY CELLS AND BOND BEAM COURSES YI+ITH REBAR TO BE GROUTED (DO NOS SOLID GROUT ENTIRE WALL.USE ` :Y,• GROUT STOP MESH AS APPROPRIATE) FOOTING OPTION A ` (TYPICAL ALL REBAR SHALL HAVE A MINIMUM OF 3"CONCRETE COVER AT FOOTINGS DESIGN PARAMETERS; WESTERN RIVERSIDE COUNTY CODE UNIFORMITY PROGRAM ACTIVE SOIL PRESSURE(PSF) =30 �� P COEFFICIENT OF FRICTION ASSIVESOILBEARING(PSF) =150 CITY OF IV�ENIFEE =0.25 ALLOWABLE SOIL BEARING(PSF) =1500 >E=NIE BUILDING & SAFETY DIVISION WIND=80 MPH,EXPOSURE C ,1 ®�� SEISMIC: FREESTANDING BLOCK WALL NA=1.3,NV=1.6•Z=0.A,SOIL PROFILE=SD �`4-zx- 951.672.6777 29714. HAUN ROAD MENIFEE, CA 92586