PMT16-01215 City of Menifee Permit No.: PMT16-01215
29714 HAUN RD. Type: Residential Addition
ACCELA'. MENIFEE, CA 92586
MENIFEE Date Issued:
0 511 8/2 01 6
PERMIT
Site Address: 25656 SOLELL CIR,MENIFEE,CA 92685 Parcel Number: 329-380-021
Construction Cost: $884.00
Existing Use: 1 &2 Family Residence Proposed Use:
Description of WALL TR 29495-7 JASPER PLACE
Work: 6'X 17 L FT
LOT
Owner Contractor
FH Il, LLC FH II HOMEBUILDERS INC
8300 UTICA AVE#300 8300 UTICA AVENUE 300
RANCHO CUCAMONGA, CA 91730 RANCHO CUCAMONGA, CA 91730
Applicant Phone:9093548000
HEATHER ALVAREZ License Number:985046
FH II HOMEBUILDERS INC
8300 UTICA AVENUE 300
RANCHO CUCAMONGA, CA 91730
Fee Description DIV Amount I$1
Building Permit Issuance 1 27.00
Wall/Fence,standard 1 83.00
GREEN FEE 1 1.00
SMIP RESIDENTIAL 1 1.00
General Plan Maintenance Fee-Building 1 4.15
$116.15
The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and
specifications or from preventing builiding operations being carried on thereunder when in violation of the Building Code or of any other
ordinance of City of Menifee.Except as otherwise stated,a permit for construction under which no work is commenced within six
months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be
forfeited.
AA_Bldg_Permit_Template.rpt Page 1 of 1
CITY OF MENIFEE
LICENSED DECLARATION property who builds or improves thereon,and who contracts for the projects
with a licensed contractor(s)pursuant to the Contractors State License Law).
I hereby affirm under penalty of perjury that i am under provisions of
Chapter!)(commencing with section 7000)of Division 3 of the Business and ❑I am exempt from licensure under the Contractors State License Law for
Professions Code and my license is in full force and effect. the following reason:
License Class License No. By my signature below I acknowledge that,except for my personal residence
Expires Signature in which I must have resided for at least one year prior to completion of
improvements covered by this permit.I cannot legally sell a structure that I
WORKER'S COMPENSATION DECLARATION have built as an owner-builder if it has not been constructed in its entirety by
❑I hereby affirm under penalty of perjury one of the following declarations:I licensed contractors.I understand that a copy of the applicable law,Section
have and will maintain a certificate of consent of self-insure for worker's 7044 of the Business and Professions Code,is available upon request when
compensation,issued by the Director of Industrial Relations as provided for this application is submitted or at the following website:
by Section 3700 of the Labor Code,for the performance of work for which www.leginfo.ca.gov/calaw.htmi.
this permit is issued.
Policy If Date
PROPERTY OWNER OR AUTHORIZED AGENT
❑I have and will maintain worker's compensation insurance,as required by
section 3700 of the Labor Code,for the performance of the work for which ❑By my signature below I certify to each of the following:I am the property
this permit is issued.My workers compensation insurance carrier and policy owner or authorized to act on the property owner's behalf.I have read this
number are: application and the Information I have provided is correct.I agree to comply
with all applicable city and county ordinances and state laws relating to
Carrier building construction.I authorize representatives of this city or county to
Policy# Expires enter the above identified property for inspection purposes.
(This section need not to be completed is the permit is for one-hundred Date
dollars($100)or less PROPERTY OWNER OR AUTHORIZED AGENT
❑I certify that in the performance of the work for which this permit is issued,
I shall not employ any persons in any manner so as to become subject to the CITY BUSINESS LICENSE#
workers compensation laws of California,and agree that if I should become HAZARDOUS MATERIAL DECLARATION
subject to theworkers compensation provisions of Section 3700 of the Labor
Code,Ishall forthwith comply with those provisions. Will the applicant or future building occupant handle hazardous material or a
mixture containing a hazardous material equal to or greater that the
Applicant Date amounts specified on the Hazardous Materials Information Guide?
WARNING:FAILURE TO SECURE WORKER'S COMPENSATION COVERAGE IS o Yes ❑No
UNLAWFUL,AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES Will the intended use of the building by the applicant or future building
AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS($100,000),IN occupant require a permit for the construction or modification from South
ADDITION TO THE COST OF COMPENSATION,DAMAGES AS PROVIDED FOR Coast Air Quality Management District(SCAQMD)?See permitting checklist
IN SECTION 3706 OF THE LABOR CODE,INTEREST,AND ATTORNEYS FEES for guidelines
CONSTRUCTION LENDING AGENCY ❑Yes ❑No
I hereby affirm that under the penalty of perjury there is a construction Will the proposed building or modified facility be within 1000 feet of the
lending agency for the performance of the work which this permit is issued outer boundary of a school?
(Section 3097 Civil Code) ❑Yes ❑No
OWNER BUILDER DECLARATIONS I have read the Hazardous Material Information Guide and the SCAQMD
I hereby affirm under penalty of perjury that I am exempt from the permitting checklist.I understand my requirements under the State of
California Health&Safety Code,Section 25505 and 25534 concerning
Contractors License Law for the reason(s)indicated below by the hazardous material reporting.
checkmark(s)I have placed next to the applicable item(s)(Section 7031.5 Ayes ❑No
Business and Professions Code).Any city or county that requires a permit to Date
construct,alter,improve,demolish or repair any structure,prior to its PROPERTY OWNER OR AUTHORIZED AGENT
issuance,also requires the applicant for the permit to file a signed statement
that he or she is licensed pursuant to the provisions of the Contractors State EPA RENOVATION,REPAIR AND PAINTING(RRP)
License Law(Chapter 9(commencing with Section 7000)of Division 3 of the The EPA Renovation,Repair and Painting(RRP)Rule requires contractors
Business and Professions Code)or that he or she is exempt from licensure receiving compensation for most work that disturbs paint in a pre-1978
and the basis for the alleged exemption.Any violation of Section 70315 by residence or childcare facility to be RRP-certified firms and comply with
an Applicant for a permit subjects the applicant to a civil penalty of not more required practices.This includes rental property owners and property
than($500). managers who do the paint-disturbing work themselves or through their
a 1,as owner of the property,or my employee with wages as their sole employees.For more information about EPA's Renovation Program visit:
compensation,will do( )all of or( )portion of the work,and the structure is www.eoa.gov/lead or contact the National Lead Information Center at
not Intended or offered for sale.(Section 7044,Business and Professions 1-800-424-LEAD(5323).
Code;The Contractors State License Law does not apply to an owner of a o An EPA Lead-Safe Certified Renovator will be responsible for this project
property who,through employees'or personal effort,builds or improves the
property provided that the improvements are not intended or offered for Certified Firm Name:
sale.If,however,the building or improvement is sold within one year of Firm Certification No.:
completion,the Owner-Builder will have the burden of proving that it was
not built or improved for the purpose of sale. ❑No EPA Lead-Safe Certified Firm is required for this project because:
❑I,as owner of the property am exclusively contracting with licensed
contractors to construct the project(Section 7044,Business and Professions
Code:The Contractors State License Law does not apply to an owner of a if your project does not comply with EPA RAP rule please fill out the RAP
Acknowledgement.
APPLICATION
BUILDING & SAFETY PERMIT/PLAN CHECK
Menifee
DATE 04/0 612 0 1 6 PERMIT/PLAN CHECK NUMBER
TYPE: []COMMERCIAL ❑✓ RESIDENTIAL MULTI-FAMILY ❑MOBILEHOME ❑POOL/SPA ❑SIGN
SUBTYPE: []ADDITION []ALTERATION ❑DEMOLITION []ELECTRICAL ❑MECHANICAL
❑NEW []PLUMBING ❑RE-ROOF-NUMBER OF SQUARES
DESCRIPTION OF WORK Block Wall Returns �\ X I T
PROJECTADDRESS 25(e U G%([
ASSESSOR'S PARCEL NUMBER �Zq ^?j�o— �L( LOT TRACT 29495-7
PROPERTY OWNER'S NAME FH II, LLC
ADDRESS 8300 UTICA AVE,STE 300, RANCHO CUCAMONGA,CA 91730'
PHONE (909)354-8000 EMAIL HALVAREZ@FRONTIER-ENTERPRISES.COM
APPLICANT NAME HEATHER ALVAREZ
ADDRESS 8300 UTICA AVE,STE 300, RANCHO CUCAMONGA,CA 91730
PHONE (909)354-8013 EMAIL HALVAREZ@FRONTIER-ENTERPRISES.COM
CONTRACTOR'S NAME OWNER BUILDER? ❑✓ YES❑NO
BUSINESS NAME
ADDRESS
PHONE EMAIL
CONTRACTOR'S STATE LIC NUMBER 985046 LICENSE CLASSIFICATION B
VALUATION$ ��� SO FT L SQ FT , \
APPLICANT'S SIGNATURE DATE 04/O6/2016
CITY STAFF USE ONLY
DEPARTMENT DISTRIBUTION CITY OF MENIFEE BUSINESS UCENSE NUMBER
BUILDING PLANNING ENGINE^ERING FIRE GREEN SMIP
INVOICE
AMOUNT '*. ! PAID AMOUNT
O CASH O CHECK R O CREDIT GARD VISA/MC
PLAN CHECK FEES PAIDAMOUNT 0CASH 0CHECK# OCREDITCARD VISA/MC
OWNER BUILDER VERIFIED OYES C NO DL NUMBER NOTARIZED LETTER O YES 0 NO
Citv of Menifee Building&Safety Depurtment29714 Houn Rd. Menifee, CA 92586 951-672-6 77
Ivw w.C ityofinen lfee.us Inspection Request Liar->95 2-246-62.
City-—ofMej�ire—e
FQQTING QFTIQN "A" BUilding Dept FOOTING OPTION 6S��
L 44HWI ONTURIAR
(USE BOND BEAM BLOCK)
Received
I
6" OR 8"BLOCK 0 NIFEE
"H" BUILDI ND SAEM D R
H
HEIGHT FROM TOP ------ #4 HORIZONTAL AT 32" MAX.O.C. OVA HT FROM TOP
OF FOOTING (USE BOND BEAM BLOCK) FO NG
SEE TABLE"A" SEE TABLE"B"
FOR REBAR SIZE FOR REBAR SIZE B
AND SPACING AND SPAC=R
(LOCAMMBARINCENTMOFCMA LOCATEREBARINCIWMOFC-ll
FINISH GRADE
(1)-*4 plansshalln tbeconstr dtob,
------------
REBAR - \
ions I the fe,
ONTINUOUS 11 1 nlAtinn of any rOVIS
........... appi ived pli
< Mr
is set
(2)-#4 REBAR c 12"
C )NnNUOUS c in e n.
Fill . ....................
. .. ..... .......
REVERSE = —
DIRECTION OF W1,
W-
HOOK ON EVERY "(FOOTIN"GWIDTf-10 �(FOOTINGWIDTH)l
OTHER REBAR SEETABLE"A" SEETABLE"B'
ALL FOOTINGS ADJACENT TO
SLOPES TO BE AT LEAST 5'TO
H" .1w,l VERTICAL DAYUGHTAS SHOWN BELOW. "H W', VERTICAL
REINFORCEMENT REINFORCEMENT
3' 17" #4 @)4811 O.C. 3- 191' #4 @
4' 20" #4 La 4811 O.C. 44 22 IT #4 @ 4811 O.C.
5' 23" #4 @)4811 O.C. 51 29" 1#4 @ 48"O.C.
TT
6' 29" #4 La 24"O.C. 60 2 FM
51 MIN.. 6' 34" 1#4 @ 24-1 O.C.
FOOTING
NOTES: CHECK WITH.T.H-19.13.PILPIN-0.1)9.PARTM-E<NT TO
1)THIS DESIGN DOES NOT ALLOW GRADE DIFFERENTIALS OF VERB IF ARWILDiNg PERMIT 16 RF:Q41j13ZD.
MORE THAN 611 ON OPPOSING SIDES OF THE WALL. THIS IS WHEN A PERMIT IS REQUIRED,THE FOLLOWING
NQTA RETAINING WALL. INSPECTIONS ARE REQUIRED:
2)FENCE HEIGHTS ARE REGULATED—CONSULT ZONING 1)FQ-QTlfjQ;EXCAVATION TRENCH CLEAN WITH
REGULATIONS BEFORE BEGINNING CONSTRUCTION. STEEL IN PLACE AND SUPPORTED 3"ABOVE AND
3)NO WATER COURSE OR NATURAL DRAINAGE SHALL BE AWAY FROM THE SURROUNDING EARTH/DIRT.
OBSTRUCTED. 2)F.?EF3&R!Pf?F.'IGROVr BOND BEAM REBAR AND
4)GROUT ONLY THE CELLS CONTAINING REBAR. THIS WALL VERTICAL REBAR IN PLACE-INSPECTION PRIOR TO
IS NOT DESIGNED FOR ALL CELLS TO BE GROUTED. PLACING GROUT. •*wpm
5)ALL REBAR TO BE ASTM SPEC.A61 5,GRADE 40 MINIMUM. 3)FINAL;AFTER GROUT IS PLACED-PRIOR TO ANY
6)ALL REBAR LAP SPLICES To BE 24�1 MINIMUM. DECORATIVE CAP PLACEMENT.
7)ALL MASONRY UNITS TO BE As-rm C-90 GRADE N.
8)REBAR TO BE CENTERED IN MASONRY CELLS. WESTERN RIVERSIDE COUNTY CODE UNIFORMITY PROGRAiv-'I
'SEE PAGE 2 FOR ADDITIONAL INFORMATION' CITY OF MENIFEE JID
Dj,5QLAjMER. BUILDING & SAFETY DIVISION
ALTERNATE DESIGNS MAY BE POSSIBLE
WHEN PROVIDED WITH AN ENGINEERED FREESTANDING BLOCK WALL
ANALYSIS. USE OF THIS STANDARD DESIGN *�,�
IS AT THE USER'S RISK AND CARRIES NO 1 29714 HAUN ROAD
IMPLIED OR INFERRED GUARANTEE AGAINST 1 951.672.6777
FAILURE OR DEFECTS. I IMENIFEE, CA 92586
RER AR—.P LAC ENT
ILLUSTRATION
FOOTING. OPTION Q
(TYPICAL) 14
ALL REBAR SPLICES
24" MIN. OVERLAP
D %l :
orci
rI
UYPICAL)
ONLY CELLS AND BOND BEAM
COURSES WITH REBAR TO BE
GROUTED
(DO!)LQT SOLID GROUT ENTIRE WALL-USE
GROUT STOP MESH AS APPROPRIATE)
FOOTING OPTIQN.A
(TYPICAL)
ALL REBAR SHALL HAVE A
MINIMUM OF 311 CONCRETE
COVER AT FOOTINGS
DESIGN PARAMETERS:
WESTERN RIVERSIDE COUNTY CODE UNIFORMITY PROGRAM
ACTIVE SOIL PRESSURE(PSF) =3o
PASSIVE SOIL BEARING(PSF) =150 CITY OF MENIFEE
COEFFICIENT OF FRICTION =0.25
ALLOWABLE SOIL BEARING(PSF) =1500 f BUILDING & SAFETY DIVISION
WIND=80 MPH,EXPOSURE C
SEISMIC- FREESTANDING BLOCK WALL
NA=1.3,Nv=1.6,Z=OA SOIL PROFILE=SD
951.672.6777 29714 HAUN ROAD
MENIFEE, CA 92586