PMT16-01214 City of Menifee Permit No.: PMT16-01214 29714 HAUN RD. Type: Residential Addition �!-�CCELA? MENIFEE,CA 92586 MENIFEE Date Issued: 05118/2016 PERMIT Site Address: 25668 SOLELL CIR, MENIFEE, CA 92585 Parcel Number: 329-380-020 Construction Cost: $884.00 Existing Use: 1 &2 Family Residence Proposed Use: Description of WALL TR 29495-7 JASPER PLACE Work: 6'X 17 L FT LOT 3 Owner Contractor FH II, LLC FH II HOMEBUILDERS INC 8300 UTICA AVE#300 8300 UTICA AVENUE 300 RANCHO CUCAMONGA,CA 91730 RANCHO CUCAMONGA,CA 91730 Applicant Phone:9093548000 HEATHER ALVAREZ License Number..985046 FH 11 HOMEBUILDERS INC 8300 UTICA AVENUE 300 RANCHO CUCAMONGA,CA 91730 Fee Description ON Amount($1 Building Permit Issuance 1 27.00 Wall/Fence,standard 1 83.00 GREEN FEE 1 1.00 SMIP RESIDENTIAL 1 1.00 General Plan Maintenance Fee-Building 1 4.15 $116.15 The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and specifications or from preventing builiding operations being carried on thereunder when in violation of the Building Code or of any other ordinance of City of Menifee.Except as otherwise stated,a permit for construction under which no work is commenced within six months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be forfeited. AA_Bldg_Permit_Templatespt Page 1 of 1 CITY OF MENIFEE LICENSED DECLARATION property who builds or improves thereon,and who contracts forthe projects I hereby affirm under penalty of perjury that I am under provisions of with a licensed contractor(s)pursuant to the Contractors State License Law). Chapter9(commencing with section 7000)of Division 3 of the Business and ❑I am exempt from Iicensure under the Contractors State License Law for Professions Code and my license is in full force and effect. the following reason: License Class License No. By my signature below I acknowledge that,except for my personal residence Expires Signature In which I must have resided for at least one year prior to completion of improvements covered by this permit.I cannot legally sell a structure that I WORKER'S COMPENSATION DECLARATION have built as an owner-builder if it has not been constructed in its entirety by ❑I hereby affirm under penalty of perjury one of the following declarations:I licensed contractors.I understand that a copy of the applicable law,Section have and will maintain a certificate of consent of self-insure for workers 7044 of the Business and Professions Code,is available upon request when compensation,issued by the Director of Industrial Relations as provided for this application is submitted or at the following website: by Section 3700 of the Labor Code,for the performance of work for which www.lexinfo.ca.gov/calaw.html.permit is issued. Policy 8 Date ❑I have and will maintain workers compensation insurance,as required by PROPERTY OWNER OR AUTHORIZED AGENT section 3700 of the Labor Code,for the performance of the work for which D By my signature below I certify to each of the following:I am the property this permit is issued.My workers compensation insurance carrier and policy owner or authorized to act on the property owners behalf.I have read this number are: application and the information I have provided is correct.I agree to comply with all applicable city and county ordinances and state laws relating to Carrier building construction.I authorize representatives of this city or county to Policy p Expires enter the above identified property for inspection purposes. (This section need not to be completed is the permit is for one-hundred Date dollars($100)or less PROPERTY OWNER OR AUTHORIZED AGENT ❑I certify that in the performance of the work for which this permit is issued, I shall not employ any persons in any manner so as to become subject to the CITY BUSINESS LICENSE k workers compensation laws of California,and agree that if I should become HAZARDOUS MATERIAL DECLARATION subject to the worker's compensation provisions of Section 3700 of the Labor Code,I shall forthwith comply with those provisions. Will the applicant or future building occupant handle hazardous material or a Applicant Date mixture containing a hazardous material equal to or greater that the amounts specified on the Hazardous Materials Information Guide? WARNING:FAILURE TO SECURE WORKER'S COMPENSATION COVERAGE IS ❑Yes ❑No UNLAWFUL,AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES Will the intended use of the building by the applicant or future building AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS($100,000),IN occupant require a permit for the construction or modification from South ADDITION TO THE COSTOF COMPENSATION,DAMAGES AS PROVIDED FOR Coast Air Quality Management District(SCAQMD)?See permitting checklist IN SECTION 3706 OF THE LABOR CODE,INTEREST,AND ATTORNEYS FEES for guidelines CONSTRUCTION LENDING AGENCY ❑Yes ❑No I hereby affirm that under the penalty of perjury there is a construction Will the proposed building or modified facility be within 1000 feet of the lending agency for the performance of the work which this permit is issued outer boundary of school? (Section 3097 Civil Code) ❑Yes ❑No OWNER BUILDER DECLARATIONS I have read the Hazardous Material Information Guide and the SCAQMD permitting checklist.I understand my requirements under the State of I hereby affirm under penalty of perjury that I am exempt from the California Health&Safety Code,Section 25505 and 25534 concerning Contractors License Law for the reason(s)indicated below by the hazardous material reporting. checkmark(s)I have placed next to the applicable item(s)(Section 7031.5 oyes ❑No Business and Professions Code).Any city or county that requires a permitto Date construct,alter,improve,demolish or repair any structure,prior to Its PROPERTY OWNER OR AUTHORIZED AGENT issuance,also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractors State EPA RENOVATION,REPAIR AND PAINTING fRRPI License Law(Chapter 9(commencing with Section 7000)of Division 3 of the The EPA Renovation,Repair and Painting(RRP)Rule requires contractors Business and Professions Code)or that he or she is exempt from licensure receiving compensation for most work that disturbs paint in a pre-1978 and the basis for the alleged exemption.Any violation of Section 7031.5 by residence or childcare facility to be RRP-certified firms and comply with an Applicant far a permit subjects the applicant to a civil penalty of not more required practices.This includes rental property owners and property than($S00). managers who do the paint-disturbing work themselves or through their ❑1,as owner of the property,or my employee with wages as their sole employees.For more information about EPA's Renovation Program visit: compensation,will do( )all of or( )portion of the work,and the structure is www.eoa.eov/lead or contact the National Lead Information Center at not intended or offered for sale.(Section 7044,Business and Professions 1-800-424-LEAD(5323). Code;The Contractors State License Law does not apply to an owner of a ❑An EPA Lead-Safe Certified Renovator will be responsible for this project property who,through employees'or personal effort,builds or improves the property provided thatthe improvements are not intended or offered for Certified Firm Name: sale.If,however,the building or improvement is sold within one year of Firm Certification No.: completion,the Owner-Builder will have the burden of proving that it was not built or improved for the purpose of sale. ❑No EPA Lead-Safe Certified Firm is required for this project because: ❑I,as owner of the property am exclusively contracting with licensed contractors to construct the project(Section 7044,Business and Professions Code:The Contractors State License Law does not apply to an owner of a If your project does not comply with EPA RRP rule please fill out the RRP Acknowledgement. PERMIT/PLANBUILDING & SAFETY APPLICATION Menifee DATE 04/06/2016 PERMIT/PLAN CHECK NUMBER 't - I TYPE: ❑COMMERCIAL ❑✓ RESIDENTIAL [-]MULTI-FAMILY ❑MOBILEHOME POOL,/SPA [-]SIGN SUBTYPE: ❑ADDITION ❑ALTERATION []DEMOLITION ❑ELECTRICAL []MECHANICAL [-]NEW ❑PLUMBING ❑RE-ROOF-NUMBER OF SQUARES DESCRIPTION OF WORK Block Wall Returns PROJECT ADDRESS Z13 Cp CA 14P—, l Gle ASSESSOR'S PARCEL NUMBERL�=j " 'J�' C)2,0 LOT -3 TRACT 29495-7 PROPERTY OWNER'S NAME FH II, LLC ADDRESS 8300 UTICA AVE,STE 300, RANCHO CUCAMONGA,CA 91730' PHONE (909)354-8000 EMAIL HALVAREZ@FRONTIER-ENTERPRISES.COM APPLICANTNAME HEATHERALVAREZ ADDRESS 8300 UTICA AVE,STE 300, RANCHO CUCAMONGA,CA 91730 PHONE (909)354-8013 EMAIL HALVAREZ@FRONTIER-ENTERPRISES.COM CONTRACTOR'S NAME OWNER BUILDER? ❑d YES❑NO BUSINESS NAME ADDRESS PHONE EMAIL CONTRACTOR'S STATE LIC NUMBER 985046 LICENSE CLASSIFICATION B VALUATION$ ��y SO FT L SQ FT \ X 17 APPLICANT'S SIGNATURE DATE 04/06/2016 CiTYSTAFF USE .NLY 1 DEPARTMENT DISTRIBUTION '� CITY OF MENIFEE BUSINESS UCEN5E NUMBER BUILDING PLANNING ENGINEERING FIRE I GREEN SMIP INVOICE 5 PAIDAMOUNT AMOUNT OCASH OCHELKN OCREDIT CARD VISA/MC PLAN CHECK FEES PAIDAMOUNT OCASH OCHECKR OCREDITCARD VISA/MC OWNER BUILDER VERIFIED OYES O NO DLNUMBER NOTARIZEDLETTER O YES O NO City of Menifee Building& Safety Deportment 29714 Houn Rd. Menifee, CA 9% 36 q51-672-6777 Lvww cityofinenifee.us Inspection Request Lhie 951-246-621-' City of Menifee FOOTING QPTJQN "A" Building Dept FOOTING OPTION class L 44 MWI ONJI-49L (USE BOND BEAM BLOCJ-0 ....... ......... Received NIFEE 611 OR 8" BLOCK BUILDI ND SAF, DE PAR I'Ty HEIGHT FROM TOP #4 HORIZONTAL AT 3211 MAX.o.c.. OVAEHTFROMTOP OF FOOTING (USE BOND BEAM BLOCK) F NG --B SEE TABLE"A" SEETABLE"B" SIZE FOR REBAR SIZE FOR REBAR tV�; :6 ANDSPACING ANDSpACING1 L (LOCATE PEIM IN CENTER OF CELL) (i-OCATEREMR IN CENTER OF CELL) FINISH GRADE S constri �d to b: REBAR I A-kPl 0a plans (1) #4 ', I —101 isions the fe, ONTINUOUS of appi �ved pli I t (2)-#4 REBAR di ns set 14IIII CONTINUOUS ; 1 2" mlen. REVERSE DIRECTION OF "W" W- ---Oj HOOK ON EVERY OTHER REBAR =NGWIDTHI) �(FOOTNGWIDTH)l IA SEE TABLE"A" SEETABLE"S" ALL FOOTINGS ADJACENTTO SLOPES TO BE AT LEAST 51 To ............. ............ 11... I.W11 VERTICAL' ems....."L — DAYLIGHT AS SHOWN BELOW. 11 VERTICAL H REINFORCEMENT H" REINFORCEMENT 3' 171' #4 @ 4811 O.C. 31 19" #4 @ 4811 O.C. V" 4' 20" #4 Ca 4811 O.C. 4' 22" #4 @ 4811 O.C. 5' 23" #4 @ 48"O.C. 5' 29" #4 @ 413"O.C. 6' 29" #4 Ca 24"O.C. BOTTOM OF 61 34" #4 @ 24"O.C. FOOTING sAaw. NOTES: CHECK WrW THJE-BjUjL-DjN-Q.Q9PARrMKNT TO 1)THIS DESIGN DOES NOT ALLOW GRADE DIFFERENTIALS OF VE111IFY IF ABUILIVINQ PFRIVIET is MORE THAN 61'ON OPPOSING SIDES OF THE WALL. THIS is WHEN A PERmrr IS REQUIRED,THE FOLLOWING NQT A RETAINING WALL. INSPECTIONS ARE REQUIRED: 2)FENCE HEIGHTS ARE REGULATED—CONSULT ZONING 1)E-00'ERMQ;EXCAVATION TRENCH CLEAN WITH REGULATIONS BEFORE BEGINNING CONSTRUCTION. STEEL IN PLACE AND SUPPORTED 3"ABOVE AND 3)NO WATER COURSE OR NATURAL DRAINAGE SHALL BE AWAY FROM THE SURROUNDING EARTH/DIRT. OBSTRUCTED. 2)F?r;0AF?jP-RE-GRO!JT;,BOND BEAM REBAR AND 4)GROUT ON L-Y THE CELLS CONTAINING REBAR. THIS WALL VERTICAL REBAR IN PLACE-INSPECTION PRIOR To IS NOT DESIGNED FOR ALL CELLS TO BE GROUTED. PLACING GROUT. 5)ALL REBAR TO BE ASTM SPEC.A61 5.GRADE 40 MINIMUM. 3)FINAL;AFTER GROUT is PLACED-PRIOR TO ANY 6)ALL REBAR LAP SPLICES To BE 2411 MINIMUM. DECORATIVE CAP PLACEMENT. 7)ALL MASONRY UNITS TO BE AsTm C-90 GRADE N. 8)REBAR TO BE CENTERED IN MASONRY CELLS. WESTERN RIVERSIDE COUNTY CODE UNIFORMITY PROGRAM *SEE PAGE 2 FOR ADDITIONAL INFORMATION* .1 CITY OF MENIFEE DISCLAIMER; LAIMER: Nip BUILDING &L SAFETY DIVISION ALTERNATE DESIGNS MAY BE POSSIBLE WHEN PROVIDED WITH AN ENGINEERED m ANALYSIS. USE OF THIS STANDARD DESIGN FREESTANDING BLOCK WALL IS AT THE USER'S RISK AND CARRIES NO 29714 HAUN ROAD IMPLIED OR INFERRED GUARANTEE AGAINST 951.672.6777 FAILURE OR DEFECTS. MENIFEE, CA 92586 RSBAR..PLACENINT ILLUSTRATION FOOTING OPTION B (TYPICAL) ALL REBAR SPLICES 24" MIN. OVERLAP D i Of CI he.; t me 4yY F t1 (f YPICAU ONLY CELLS AND BOND BEAM COURSES WITH REBAR TO BE `• GROUTED (DO NOT SOLID GROUT ENTIRE WALL-USE \, GROUT STOP MESH AS APPROPRIATE) ~ 1, FOOTING OPTION A I� (TYPICAL) ALL REBAR SHALL HAVE A MINIMUM OF 317 CONCRETE COVER AT FOOTINGS DESIGN PARAMETERS: WESTERN RIVERSIDE COUNTY CODE UNIFORMITY PROGRAM) ACTIVE SOIL PRESSURE(PSF) =30 PASSIVE SOIL BEARING(PSF) =1.50 �a COEFFICIENT OF FRICTION =0.25 - CITY OF MIENIFEE ALLOWABLESOIL BEARING(PSF) =1500 Ffrt Y BUILDING & SAFETY DIVISION WIND=BO MPH,EXPOSURE C SEISMIC: FREESTANDING BLOCK WALL NA=1.3.3,Nv=1.6,Z=0.4,SOIL PROFILE=So �^+�' 951.672.6777 29714. HAUN ROAD IVIENIFEE, CA 92586