Loading...
PMT16-01188 City of Menifee Permit No.: PMT16-01188 29714 HAUN RD. -qX-CCEL/-> MENIFEE, CA 92586 Type: Residential Electrical MENIFEE Date Issued: 04I27I2016 PERMIT Site Address: 30107 MUIRLANDS DR,MENIFEE,CA Parcel Number: 364-370-066 92584 Construction Cost: $7,650.40 Existing Use: Proposed Use: Description of SOLAR TR 30422-3 CAMELLIA Work: 11 MODULES 2.92KW LOT 167 Owner Contractor LENNAR HOMES OF CA LENNAR HOMES OF CALIFORNIA INC 980 MONTECITO DR#302 25 ENTERPRISE CORONA, CA 92879 ALISO VIEJO,CA 92656 Applicant Phone:9493498269 JEREMIAH ACAYTURRI License Number: 728102 LENNAR HOMES OF CALIFORNIA INC 25 ENTERPRISE ALISO VIEJO,CA 92656 Fee Description city Amount(S) Solar, Residential or Small Commercial 1 252.00 Building Permit Issuance 1 27.00 GREEN FEE 1 1.00 SMIP RESIDENTIAL 1 1.00 General Plan Maintenance Fee-Electrical 1 12.60 $293.60 The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and specifications or from preventing builiding operations being carried on thereunder when in violation of the Building Code or of any other ordinance of City of Menifee.Except as otherwise slated,a permit for construction under which no work is commenced within six months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be forfeited. AA_Bldg Permit_Template.rpt Page 1 of 1 CITY OF MENIFEE LICENSED DECLARATION property who builds or improves thereon,and who contracts for the projects I hereby affirm under penalty of perjury that I am under provisions of with a licensed contractor(s)pursuant to the Contractors State License Law). Chapter9(commencing with section 7000)of Division 3 of the Business and ❑I am exempt from Ilcensureunder the Contractor's State License Law for Professions Code and my license is in full force and effect. the following reason: License Class License No. By my signature below I acknowledge that,except for my personal residence Expires Signature in which I must have resided for at least one year prior to completion of improvements covered by this permit.I cannot legally sell a structure that I WORKER'S COMPENSATION DECLARATION have built as an owner-builder if it has not been constructed in its entirety by ❑I hereby affirm under penalty of perjury one of the following declarations:I licensed contractors.I understand thata copy of the applicable law,Section have and will maintain a certificate of consent of self-insure for worker's 7044 of the Business and Professions Code,is available upon request when compensation,issued bythe Director of Industrial Relations as provided for this application is submitted or at the following website: by Section 3700 of the Labor Code,for the performance of work for which vnvw.leeinfo.ca.eov/calaw.html. this permit is issued. Policy If Date PROPERTY OWNER OR AUTHORIZED AGENT ❑1 have and will maintain worker's compensation insurance,as required by section 3700 of the Labor Code,for the performance of the work for which ❑By my signature below I certify to each of the following:I am the property this permit is issued.My workers compensation insurance carrier and policy owner or authorized to act on the property owners behalf.I have read this number are: application and the information I have provided is correct.I agree to comply with all applicable city and county ordinances and state laws relating to Carrier building construction.I authorize representatives of this city or county to Policy# Expires enter the above identified property for inspection purposes. (This section need not to be completed is the permit is for one-hundred Date dollars($100)or less PROPERTY OWNER OR AUTHORIZED AGENT ❑I certify that in the performance of the work for which this permit is issued, I shall not employ any persons In any manner so as to become subject to the CITY BUSINESS LICENSE# workers compensation laws of California,and agree that if I should become HAZARDOUS MATERIAL DECLARATION subject to the workers compensation provisions of Section 3700 of the Labor Code,I shall forthwith comply with those provisions. WIII the applicant or future building occupant handle hazardous material or a Applicant Date mixture containing a hazardous material equal to or greater thatthe amounts specified on the Hazardous.Materials Information Guide? WARNING:FAILURE TO SECURE WORKER'S COMPENSATION COVERAGE IS ❑Yes ❑No UNLAWFUL,AND SHALL SUBJECTAN EMPLOYER TO CRIMINAL PENALTIES Will the intended use of the building by the applicant or future building AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS($100,000),IN occupant require a permit for the construction or modification from South ADDITION TO THE COST OF COMPENSATION,DAMAGES AS PROVIDED FOR Coast Air Quality Management District(SCAQMD)?See permitting checklist IN SECTION 3706 OF THE LABOR CODE,INTEREST,AND ATTORNEYS FEES for guidelines CONSTRUCTION LENDING AGENCY ❑Yes ❑No I hereby affirm that under the penalty of perjury there is a construction Will the proposed building or modified facility be within 1000 feet of the lending agency for the performance of the work which this permit is issued outer boundary of a school? (Section 3097 Civil Code) ❑Yes ❑No OWNER BUILDER DECLARATIONS I have read the Hazardous Material Information Guide and the SCAQMD hereby affirm under penalty of perjury that I am exempt from the permitting checklist.I understand my requirements under the State of Contractors License Law for the reason(s)indicated below by the California Health al Safety Code,Section 25505 and 25534 concerning hazardous material reporting. checkmark(s)1 have placed next to the applicable item(s)(Section 7031.5 Ayes ❑No Business and Professions Code).Any city or county that requires a permit to Date construct,alter,improve,demolish or repair any structure,priorto its PROPERTY OWNER OR AUTHORIZED AGENT issuance,also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractors State EPA RENOVATION,REPAIR AND PAINTING(RRP1 License Law(Chapter 9(commencing with Section 70D0)of Division 3 of the The EPA Renovation,Repair and Painting(RRP)Rule requires contractors Business and Professions Code)or that he or she is exempt from Iicensure receiving compensation for most work that disturbs paint in a pre-1978 and the basis for the alleged exemption.Any violation of Section 7031.5 by residence or childcare facility to be RRP-certified firms and comply with an Applicant for a permit subjects the applicant to a civil penalty of not more required practices.This includes rental property owners and property than($500). managers who do the paint-disturbing work themselves or through their ❑I,as owner of the property,or my employee with wages as their sole employees.For more information about EPA's Renovation Program visit: compensation,will do( )all of or( )portion of the work,and the structure is www.epa.gov/lead or contact the National Lead Information Center at not intended or offered for sale.(Section 7044,Business and Professions 1-800-424-LEAD(5323). Code,The Contractors State License Law does not apply to an owner of a ❑An EPA Lead-Safe Certified Renovator will be responsible for this project property who,through employees'or personal effort,builds or improves the property provided that the improvements are not intended or offered for Certified Firm Name: sale.If,however,the building or improvement is sold within One year of Firm Certification No.: completion,the Owner-Builder will have the burden of proving that it was not built or improved for the purpose of sale. ❑No EPA Lead-Safe Certified Firm is required for this project because: ❑1,as owner of the property am exclusively contracting with licensed contractors to construct the project(Section 7044,Business and Professions Code:The Contractors State License Law does not apply to an owner of a If your project does not comply with EPA RRP rule please fill out the RRP Acknowledgement. BUILDING , SAFETY PERMIT/PLAN • • l APPLICATION Ito- M DATE 04/04/2016 PERMIT/PLAN CHECK NUMBERWgi(ol Olin TYPE: ❑COMMERCIAL H RESIDENTIAL ❑MULTI-FAMILY ❑MOBILE HOME ❑POOL/SPA ❑SIGN SUBTYPE: ❑✓ ADDITION ❑ALTERATION ❑DEMOLITION ❑ELECTRICAL [—]MECHANICAL [:]NEW []PLUMBING ❑RE-ROOF-NUMBER OF SQUARES DESCRIPTION OF WORK Solar Permit-Plan 2399-2.92kW/11 PCS Master Solar Permit Number.PMT14-02630 PROJECT ADDRESS 30107 Muirlands D(ve, Menifee, CA 92584 ASSESSOR'S PARCEL NUMBER 364-370 - c)gg LOT 167 TRACT 30422-3 PROPERTY OWNER'S NAME Lennar Homes of California, Inc. ADDRESS 980 Montecito Dr.,Suite 302,Corona,CA 92879 PHONE (951)817-3680 EMAIL jeremiah.acayturii@lennar.com APPLICANT NAME Lennar Homes of California, Inc. ADDRESS 980 Montecito Dr., Suite 302, Corona, CA 92584 PHONE (951)817-3680 EMAIL jeremiah.acayturri@lennar.com CONTRACTOR'S NAME Lennar Homes of California, Inc. OWNER BUILDER? ❑✓ YES❑NO BUSINESS NAME Lennar Homes of California, Inc. ADDRESS 980 Montecito Dr.,Suite 302,Corona,CA 92584 PHONE (951)817-3680 EMAIL jeremiah.acayturri@lennar.com CONTRACTOR'S STATE LIC NUMBER 728102 LICENSE CLASSIFICATION A&B VALUATION$ $7,650.40 SO FT L SO.FT APPLICANT'S SIGNATURE DATE 0 410 4/2 0 1 6 CITY STAFF USE ONLY DEPARTMENT DISTRIBUTION CITY OF MENIFEE BU5INE55 LICENSE NUMRER BUILDING PLANNING ENGINEERING FIRE GREEN SMIP Ito I INVOICE � 0 PAID AMOUNT AMOUNT ' /• CASH OCHECKft u CREDIT CARD VISA/MC PLAN CHECK FEES PAID AMOUNT OCASH OCHECKN CREDIT CARD VISA/MC OWNER BUILDER VERIFIED O YES C NO DL NUMBER NOTARIZED LETTER G YES 0 NO City of Menifee Building&Safety Department 29714 Haun Rd. Menifee, CA 92586 951-672-6777 www.cityofinenifee.us Inspection Request Line 951-246-6213 SYSTEM INFORMATION BUYER ACKNOWLEDGES THAT THE SOLAR MODULES TO BE INSTALLED ITEM OTY MFR. MODEL ON THE ROOF OF THE HOME WILL BE SUBSTANTIALLY IN THE SYSTEM SIZE 2.92 KW I LOCATIONS INDICATED BY THE ILLUSTRATION. MODULE II PCS-1 HYUNDAI I HIS-S265RG (265W) BUYER: INVERTER II PCS.1 ENPHASE I M215-60-2LL-S22-IG ROOF TYPE TILE W/COMPOSITE SHINGLE UNDER ARRAY DATE: SUB-ARRAY INFORMATION ARRAY#1 ARRAY#2 ARRAY#3 -'� („ly MENIFEE MOD OTY 8 3 NA City of Menifee BUYER: 10-_ AZIMUTH 1 TILT . 23' NA°NAo Building Dept I DATE; ' !0 DING AND SAFETY DE APR 19 �Gia AN APPROVAL Received ;;tl�IEWEDB`+f OU Approval of these plans shall not be constrc approval of,any violation of any provisions c re,l)lations and ordinances. This set of appr iobsite until completion- ---- ----- -- - ----- I I I t Ce of a� ---------------- _ I SOLADECK WIRE I _ TRANSITION BOX 1 (UNDER ARRAY) 00 i I r PV AC DISCONNECT J EXTERIOR-GARAGE �- UTILITY METER B ARRAY MAIN SERVICE PANEL J 13'-IO'FLASHING 3'-0' (VERIFIED BY BUILDER) N -0' 5'-5* NOTE: DIMENSIONS ARE SHOWN IN PLANE OF ROOF PLAN 2399 ELEVATION C ORIENTATION I LOT#167 LENNAR: ORIGINAL BY: JIM PARKS DATE:16.01.20 CAMELLIA AT 980 MONTECITO DRIVE,#302 REVIEWED BY:TOM FIDDES DATE:16.01.21 THE LAKES CORONA,CA 92879 REV.# BY DATE DESCRIPTION �masts SOIAR DWG TITLE: PAGE#: SCALE: SITE LOCATION: INDIVIDUAL 4577 Broadway Street 3ENI MUI CA DRIVE Boulder,CO80306 PLOT PLAN 1716'=I'-0' MENIFEE,CA 303.447.0300 SYSTEM LAYOUT MODULE SPECS AND CALCULATIONS INVERTER SPECS AND CALCULATIONS ITEM NOTE/CALC UNIT DETAIL ITEM NOTE/CALC UNIT DETAIL LOCATION MENIFEE,CA INV. MAKE INVERTER SPEC ENPHASE TEMP,AMBIENT HIGH(TMAX) ASHRAE 2% °C 37 INV. MODEL INVERTER SPEC M215-60-2LL-S22-IG TEMP.AMBIENT LOW(THIN) ASHRAE EXTR.MIN °C -2 INV. MAX POWER,(WAD MAX) INVERTER SPEC WATTS(AC) 225 TEMP,MODULE TEST(TTEST) MODULE SPEC °C 25 INV. INPUT V,(VOc MAX) INVERTER SPEC VOLTS(Oc) 48 TEMP,DELTA LOW(TDELTA) THIN-TTEST °C -27 INV. OUTPUT V.(VAC NOM) INVERTER SPEC VOLTS(AD) 240 MOD. MANUFACTURER MODULE SPEC HYUNDAI INV. OUTPUT FREOUENCY INVERTER SPEC HERTZ 60 MOD. PART NUMBER MODULE SPEC HIS-S265RG INV. OUTPUT CURRENT. IAC INVERTER SPEC AMPS(AC) 0.9 MOD.POWER STC(P) MODULE SPEC WATTS(DC) 265 INV. PHASE QUANTITY INVERTER SPEC PHASE I MOD.POWER FTC MODULE SPEC WATTS(oc) 238 COMPLIANCE INVERTER SPEC UL1741/IEEE1547 MOD. OPERATING VOLTAGE(VMP) MODULE SPEC VOLTS(OD) 31.30 INV. GROUNDING 1 INVER ISOLATED MOD. OPEN OCT.VOLTAGE(VOC) MODULE SPEC VOLTS(CC) 38.10 INV. CITY,MAX/BRANCH OCT. NV.QTYBTER SPEC C CITY II MOD. COEFF. VOLT/TEMP(COEF) MODULE SPEC V/°C -0.114 BRANCH CCT. OUTPUT, IMAXBC I (IAC•INV.QTYBD) AMPS(AC) 9.90 MOD. MAX VOLTAGE(VMAXMOO) (Vac t (TD-COEF)) VOLTS(OD) 41.18 INV. OUANTITY,TOTAL I INV.QTYT I QTY 11 MOD.OPERATING CURRENT(IMP) MODULE SPEC AMPS(00 8.50 TOTAL SYSTEM OUTPUT, IMAXTS (IAC•INV.QTYT) I AMPS(AC) 9.90 MOD.SHORT OCT.CURRENT(ISO) MODULE SPEC AMPS(CC) 9.00 MOD. MAXIMUM CURRENT(IMAX) (Isc• 1.25) AMPS(9C) 11.25 MIN. AMPACITY REQ'D,PER NEC (IMAX• 1.25) AMPS(oc) 14.06 SERIES FUSE RATING,MAX MODULE SPEC AMPS(DC) 15 ELECTRICAL EQUIPMENT SCHEDULE KEY OTY MANUFACTURER MODEL NOTES TRADE 1 II HYUNDAI HIS-S265RG(265W) PV MODULE SOLAR 2 II ENPHASE M215-60-2LL-S22-IG PV INVERTER SOLAR 3 2 RSTC/SOLADECK 0786-3R5 PV ROOF JUNCTION BOX,NEMA 3R SOLAR 4 1 CUTLER-HAMMER DG221URB PV AC DISCONNECT,NEMA 3R,24OV,30A SOLAR 5 1 ENPHASE ENVOY PV DATA MONITOR, 120V SOLAR 6 1 TBD TBD 120V DEDICATED RECEPTACLE FOR ENVOY PV DATA MONITOR SOLAR 7 1 TOD TBD CATS PORT FOR SOLAR PV INTERNET CONNECTION TO HOME NETWORK BOX SOLAR 8 NOTE CUTLER-HAMMER TBD PV BRANCH CIRCUIT BREAKERS:I X 15A-IP(ENVOY) SOLAR 9 NOTE CUTLER-HAMMER TBD PV BREAKER. I X 2OA-2P,LOCATE AT OPPOSITE END OF BUS FROM MAIN BREAKER SOLAR 10 1 TBD TBD SERVICE PANEL, MIN. 12SA BUS OLDR. ELEC. II 1 TBD I TBD UTILITY METER,]PH. 120/240V.200A 1 BLDR. ELEC. 12 TBD I TBD I GROUNDING ELECTRODE UFER I BLDR. ELEC. C TOR SIZING CALCULATIONS INTERCONNECTION CALCULATIONS D C N OF USE(COU): (AMPACITY•TEMP. DERATE• FILL DERATE) vs. REO'D(]MAX) ITEM UNIT PANEL 2) ALS(TERM): AMPACITY AT TERMINALS. vs. REG-D.(IMAX. 1.25) PANEL MFR. CUTLER-HAMMER KEY SIZE CU/AL INSULATION CALC. AMPACITY W/O TEMP. FILL RESULT REO'D OCD BUS RATING AMPS 200 TYPE DERATES DERATE DERATE A) (A) USED(A) MAIN DISCONNECT AMPS 200 A CU I THWN-2 COU 30 0.76 1.0 22.80 9.90 ALLOWED PV PER NEC AMPS 40 TERM 25 25 12.38 20 PV OCPD DEVICE USED AMPS 20 B #10 CU NM-B COU 40 0.91 1.0 36.40 9.90 TERM 35 35 12.38 20 C 0 CU NM-B COU 40 0.91 1.0 36.40 9.90 TERM 35 35 12.38 20 CONMICTOR SCHEDULE KE NDULTORS1 CU/AL I TYPE I LOCATION TRADE A 'I-#12 ENGAGE CABLE, 1-#6G,FREE AIR I CU I TC-ER I ARRAY SOLAR EGO I CU I NM-B(ROMEX) I INTERIOR SOLAR EGC I CU I NM-B(ROMEX) I NTERIOR SOLAR D CATSE,ETHERNET CABLE I CU I CATSE I INTERIOR I SOLAR �A �yI 5 6 II 7 o 0 I M - SEE NOTE 15 I 10 0 0 IsuIP G OA/BP I 1L G G GI I r ROOF EXTERIOR-GARAGE ELECTRICAL DIAGRAM 2.92 KW LOT#167 ORIGINAL BY: JIM PARKS I DATE:16.01.20 CAMELLIA AT LENNAR: REVIEWED BY:TOM FIDDES DATE:16.01.21 THE LAKES COORONNA,A.C CA 9 I2 879 DRIVE,#302 REV.# BY DATE DESCRIPTION z2namasbd A 9 SOLAR DWG TITLE: PAGE#: SCALE: SITE LOCATION: 4571 Broadway Street INDIVIDUAL 30107 MUIRLANDS DRIVE Boulder,CO 80304 PLOT PLAN 2 NTS MENIFEE,CA 303,447.0300 ELECTRICAL STRUCTURAL NOTES: SOLAR CONTRACTOR- S ALL PV ROOF ATTACHMENTS WILL BE SPACED ALONG MODULE RACKING RAILS AT NOT GREATER THAN 48'O.C. 2)ALL PV ROOF ATTACHMENTS WILL BE STAGGERED BY ROW AMONGST THE ROOF FRAMING MEMBERS,TO MAXIMUM EXTENT POSSIBLE. 3)ROOF PENETRATIONS ASSOCIATED WITH SOLAR RACKING WILL BE SEALED WITH AN APPROVED SEALANT. 4)SOLAOECK WIRE TRANSITION BOX WILL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS. IT WILL BE FLASHED AND SEALED. 5)PV ARRAY WILL BE A MINIMUM OF 3"ABOVE THE COMPOSITE SHINGLE ROOF SURFACE. 6)THE UNIRAC SOLARMOUNT RACKING SYSTEM AND SOLAR PV ARRAY WILL BE INSTALLED ACCORDING TO THE UNIRAC SOLARMOUNT CODE-COMPLIANT INSTALLATION MANUAL,VERSION 227.3,PUB 140113-ICC,JANUARY 2014. 7)UNIRAC TOP CLAMPS REQUIRE A ONE INCH(I-)SPACE BETWEEN PV MODULES. SOLARMOUNT RAILS MUST EXTEND A MINIMUM OF TWO INCHES(R'i'B!1®1 jbGE OF THE PV ARRAY/SUB-ARRAY. A 1�1�1r�•�`�•�- 8)UNIRAC SOLARMOUNT REQUIRES THAT A THERMAL EXPANSION GAP BE INSTALLED FOR.ANY RAIL LENGTH OF GREATER THAN 40'. ROOFING CONTRACTOR- I)DISTANCE BETWEEN ARRAY EDGE AND TRANSITION FLASHING(COMPOSITION TO TILE)WILL BE A MINIMUM OF 3% 2)26 GAUGE INTERLOCKING FLASHING'SIDEWALL'TO BE INSTALLED ALONG THE LENGTH OF THE PV ARRAY AT ROOFING MATERIAL TRANSITIO IT SHALL BE APROVED PRIOR TO PV SYSTEM INSTALLATION. IQI 3)PEEL-N-STICK BASE TO BE INSTALLED ONE FOOT(I')OR MORE BEYOND THE EDGE OF THE COMPOSITION SHINGLE,DOWN TO THE ROOF EAVE.— E CI S //�� _( 4)AREAS LUNDER EACH LED PER PVARRAY SHALL BE ROOFEDWITH COMPOSITION SHINGLE. COMPOSITION SHINGLE SHALL RUN FROM ABOVE THE PV ARRAY TO THE ROOF EF A�p/,TE 5)TILE INSTALLED BELOW THE ARRAY TO BE INSTALLED ABOVE THE COMPOSITION ROOF PER ROOFER SPECIFICATIONS. 6)BIRDSTOP WILL BE INSTALLED AT THE UPPERMOST TRANSITION FROM TILE TO COMPOSITION SHINGLE. BIRDSTOP TO BE SPECIFIED BY ROOFER PRIOR TO INSTALLATION. ae a permit for,or an e tederal,state or city d plans must be kept on the ELECTRICAL NOTES: GENERAL- 1)ALL PV EQUIPMENT WILL BE TESTED AND LISTED FOR ITS USE BY A NATIONALLY RECOGNIZED TESTING LABORATORY(NRTL). 2)THE GROUNDING OF THE PHOTOVOLTAIC SYSTEM SHALL COMPLY WITH THE APPLICABLE VERSION OF THE NEC/CEC. 3)ALL GROUNDING ELECTRODE CONDUCTORS WILL BE INSTALLED IN A CONTINUOUS LENGTH EXCEPT WHERE SPLICED BY AN IRREVERSIBLE CONNECTOR OR EXOTHERMIC WELD. 4)NON-CURRENT CARRYING METAL PARTS SHALL BE CHECKED FOR PROPER GROUNDING,NOTING THAT TERMINAL LUGS BOLTED ON AN ENCLOSURE'S FINISHED SURFACE MAY BE ELECTRICALLY INSULATED BECAUSE OF PAINT/FINISH. PAINT/FINISH AT POINT OF CONTACT SHALL BE PROPERLY REMOVED. 5)ROOF PENETRATIONS WILL BE COMPLETED AND SEALED PER APPLICABLE CODE. 6)ALL CONDUCTORS WILL HAVE A 90-C RATING TO ENSURE CODE COMPLIANCE. SOLAR CONTRACTOR- 7)MODULE CERTIFICATIONS WILL INCLUDE UL1703,IEC61646, IEC61730. 8)CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS. 9)RACEWAY POINT OF PENETRATION FROM EXTERIOR TO INTERIOR WILL BE SEALED TO PREVENT INGRESS OF WATER AND INSECTS. 10)DC WIRING IS LIMITED TO PV ARRAY FOOTPRINT W/ENPHASE MICRO-INVERTER SYSTEM. IU MODULE AND ENPHASE WIRING SHALL BE LOCATED AND SECURED UNDER THE ARRAY USING SUITABLE WIRING CLIPS. WIRING SMALL NOT MAKE CONTACT WITH THE ROOF SURFACE AND SHALL BE MANAGED IN A WORKMAN-LIKE MANNER. 12)EQUIPMENT GROUNDING CONDUCTORS WILL BE SIZED IN ACCORDANCE WITH NEC TABLE 250.IZ2. 13)CONDUCTOR TERMINATIONS WILL BE TORQUED PER DEVICE LISTING, OR MANUFACTURER'S RECOMMENDATIONS. 14)A PV AGGREGATION PANEL(SUB PANEL)WILL NOT BE INCLUDED FOR SYSTEMS WITH ONE BRANCH CIRCUIT. 15)A DEDICATED 120V BRANCH CIRCUIT IS REQUIRED IN MASTER CLOSET(OR EQUIVALENT)FOR ENPHASE ENVOY MONITOR. SIGNAGE- 16)PV SYSTEMS SHALL BE CLEARLY MARKED IN ACCORDANCE WITH NEC ARTICLE 690 AND OTHER APPLICABLE STATE AND LOCAL CODES. 17)ALL SAFETY MARKING /PLACARDS SHALL BE PERMANENTLY ATTACHED BY ADHESIVE OR OTHER MECHANICAL MEANS. 18)MARKING/PLACARDS WILL BE METAL OR PLASTIC WITH ENGRAVED OR MACHINE PRINTED LETTERING. BACKGROUND WILL BE RED WITH WHITE CAPITAL LETTERING OF MINIMUM HEIGHT a. 19)ALL WIRING/RACEWAYS/JUNCTION BOXES WILL BE MARKED"PHOTOVOLTAIC POWER SOURCE;OR EQUIVALENT;WIRING/RACEWAYS SHALL BE MARKED EVERY 10'. BUILDER ELECTRICAL AND SOLAR CONTRACTORS- 20)INSTALLATION SHALL BE COMPLETED IN A NEAT AND WORKMAN-LIKE MANNER. 21)SPACE REQUIREMENTS FOR ALL ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110.26. LENNAR: ORIGINAL BY: JIM PARKS DATE:16.01.20 CAMELLIA AT 980 MONTECITO DRIVE.#302 REVIEWED BY: TOM FIDDES DATE:16.01.21 THE LAKES CORONA,CA 92879 REV.# BY DATE DESCRIPTION `ta namasr e' SOLAR DWG TITLE: PAGE#: SCALE: SITE LOCATION: 4571 Broadway Street INDIVIDUAL 30107 MUIRLANDS DRIVE Boulder,CO 80304 PLOT PLAN 3 NTS MENIFEE,CA 303.447.0300 NOTES CAUTION: POWER TO THIS BUILDING IS SUPPLIED BY THE UTILITY AND A SOLAR PV SYSTEM. DISCONNECTS ARE LOCATED AS SHOWN. SOLADECK WIRE TRANSITION BOX (UNDER ARRAY) PV AC DISCONNECT EXTERIOR-GARAGE UTILITY METER 8 MAIN SERVICE PANEL (VERIFIED BY BUILDER) SERVICE BY QUALIFIED PERSONNEL ONLY CONTACT: SUNSTREET ENERGY GROUP I-877-SLR-POWR PV POWER SOURCE - AC SPECS AC OPERATING VOLTAGE: 240 V AC OPERATING CURRENT: 9.9 A NOTE: SEE MASTER SET FOR ADDITIONAL PLACARD INFORMATION : ORIGINAL BY: JIM PARKS DATE:16.01.20 CAMELLIA AT LENNAR 980 MONTECITO DRIVE, #302 REVIEWED BY: TOM FIDDES DATE:16.01.21 /� THE LAKES CORONA,CA 92979 REV.# BY DATE DESCRIPTION •1 eta namasGe SOLAR DWG TITLE: PAGE#: SCALE: SITE LOCATION: 4571 Broadway Slreel INDIVIDUAL 30107 MUIRLANDS DRIVE Boulder,CO 80304 PLOT PLAN 4 NTS MENIFEE,CA PLACARDS 303.447.0300