PMT16-01187 City of Menifee Permit No.: PMT16-01187
_ 29714 HAUN RD. Type: Residential Electrical
�/-�CCEU/? MENIFEE, CA 92586
`- ----. `'A— MENIFEE Date Issued: 0412 7/2 01 6
PERMIT
Site Address: 30119 MUIRLANDS DR,MENIFEE, CA Parcel Number: 364-370-065
92584 Construction Cost: $8,331.60
Existing Use: Proposed Use:
Description of SOLAR TR 30422-3 CAMELLIA
Work: 12 MODULES 3.18KW
LOT 166
Owner contractor
LENNAR HOMES OF CA LENNAR HOMES OF CALIFORNIA INC
980 MONTECITO DR#302 25 ENTERPRISE
CORONA, CA 92879 ALISO VIEJO, CA 92656
Applicant Phone:9493498269
JEREMIAH ACAYTURRI License Number.728102
LENNAR HOMES OF CALIFORNIA INC
25 ENTERPRISE
ALISO VIEJO,CA 92656
Fee Description OQt Amount lSl
Solar, Residential or Small Commercial 1 252.00
Building Permit Issuance 1 27.00
GREEN FEE 1 1.00
SMIP RESIDENTIAL 1 2.00
General Plan Maintenance Fee-Electrical 1 12.60
$294.60
The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and
specifications or from preventing builiding operations being carried on thereunder when in violation of the Building Code or of any other
ordinance of City of Menifee.Except as otherwise stated,a permit for construction under which no work is commenced within six
months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be
forfeited.
AA_Bldg_Pemnit Template.rpt Page 1 of 1
CITY OF MENIFEE
LICENSED DECLARATION property who builds or improves thereon,and who contracts for the projects
I hereby affirm under penalty of perjury that I am under provisions of with a licensed contractors)pursuant to the Contractors State License Law).
Chapter9(commencing with section 7000)of Division 3 of the Business and ❑I am exempt from licensum under the Contractor's State License Law for
Professions Code and my license is in full force and effect. the following reason:
License Class License No. By my signature below I acknowledge that,except for my personal residence
Expires Signature in which I must have resided for at least one year prior to completion of
improvements covered by this permit.I cannot legally sell a structure that I
WORKER'S COMPENSATION DECLARATION have built as an owner-builder if it has not been constructed in its entirety by
❑I hereby affirm under penalty of perjury one of the following declarations:I licensed contractors.I understand that copy of the applicable law,Section
have and will maintain a certificate of consent of self-insure for worker's 7044 of the Business and Professions Code,is available upon request when
compensation,issued by the Director of Industrial Relations as provided for this application is submitted or at the following website:
by Section 3700 of the labor Code,for the performance of work for which www.leeinfo.ca.aov/calaw.html.
this permit is issued.
Policy g Date
PROPERTY OWNER OR AUTHORIZED AGENT
❑I have and will maintain worker's compensation insurance,as required by
section 3700 of the Labor Code,for the performance of the work for which ❑By my signature below I certify to each of the following:I am the property
this permit is issued.My worker's compensation insurance carrier and policy owner or authorized to act on the property owners behalf.I have read this
number are: application and the information I have provided is correct.I agree to comply
With all applicable city and county ordinances and state laws relating to
Carrier building construction.I authorize representatives of this city or county to
Policy p Expires enter the above identified property for inspection purposes.
(This section need not to be completed is the permit is for one-hundred Date
dollars($100)or less PROPERTY OWNER OR AUTHORIZED AGENT
❑I certify that in the performance of the work for which this permit is issued,
I shall not employ any persons in any manner so as to become subject to the CITY BUSINESS LICENSE N
workers compensation laws of California,and agree that if I should become HAZARDOUS MATERIAL DECLARATION
subject to the workers compensation provisions of Section 3700 of the Labor
Code,I shall forthwith comply with those provisions. will the applicant or future building occupant handle hazardous material or a
Applicant Date mixture containing a hazardous material equal to or greater that the
amounts specified on the Hazardous Materials Information Guide?
WARNING:FAILURE TO SECURE WORKER'S COMPENSATION COVERAGE IS ❑Yes ❑No
UNLAWFUL,AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES Will the intended use of the building by the applicant or future building
AND OVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS($100,000),IN occupant require a permit for the construction or modification from South
ADDITION TO THE COST OF COMPENSATION,DAMAGES AS PROVIDED FOR Coast Air Quality Management District(SCAQMD)?See permitting checklist
IN SECTION 3706 OF THE LABOR CODE,INTEREST,AND ATTORNEYS FEES forguidelines
CONSTRUCTION LENDING AGENCY ❑Yes ❑No
I hereby affirm that under the penalty of perjury there is a construction Will the proposed building or modified facility be within 1000 feet of the
lending agency for the performance of the work which this permit is issued outer boundary of a school?
(Section 3097 Civil Code) D Yes ❑No
OWNER BUILDER DECLARATIONS I have read the Hazardous Material Information Guide and the SCAQMD
permitting checklist.I understand my requirements underthe State of
I hereby affirm under penalty of perjury that I am exempt from the
Contractors License Law for the reason(s)indicated below by the California Health al Safety Code,Section 25505 and 25534 concerning
hazardous material reporting.
checkmark(s)I have placed next to the applicable item(s)(Section 7031.5 pYes ❑No
Business and Professions Code).Any city or county that requires a permit to Date
construct,alter,improve,demolish or repair any structure,prior to its PROPERTY OWNER OR AUTHORIZED AGENT
issuance,also requires the applicant for the permit to file a signed statement
that he or she is licensed pursuant to the provisions of the Contractors State EPA RENOVATION,REPAIR AND PAINTING(RRP)
License Law(Chapter 9(commencing with Section 7000)of Division 3 of the The EPA Renovation,Repair and Painting(RRP)Rule requires contractors
Business and Professions Code)or that he or she is exempt from licensure receiving compensation for most work that disturbs paint in a pre-1978
and the basis for the alleged exemption.Any violation of Section 7031.5 by residence or childcare facilityto be RRP-certified firms and comply with
an Applicant for a permitsubjects the applicant to a civil penalty of not more required practices.This includes rental property owners and property
than($500). managers who do the paint-disturbing work themselves or through their
❑I,as owner of the property,or my employee with wages as their sole employees.For more information about EPA's Renovation Program visit:
compensation,will do( )all of or( )portion of the work,and the structure is www.eoa,eov/lead or contact the National Lead Information Center at
not intended or offered for sale.(Section 7044,Business and Professions 1-8D0.424-LEAD(5323).
Code;The Contractors State License Law does not apply to an owner of a ❑An EPA Lead-Safe Certified Renovator will be responsible for this project
property who,through employees'or personal effort,builds or improves the
property provided that the improvements are not intended or offered for Certified Firm Name:
sale.If,however,the building or improvement is sold within one year of Firm Certification No.:
completion,the Owner-Builder will have the burden of proving that it was
not built or improved for the purpose of sale. ❑No EPA Lead-Safe Certified Firm is required for this project because:
❑I,as owner of the property am exclusively contracting with licensed
contractors to construct the project(Section 7044,Business and Professions
Code:The Contractors State License Law does not apply to an owner of a If your project does not comply with EPA RRP rule please fill out the RRP
Acknowledgement.
BUILDINGAPPLICATION
Menifee
DATE 04/0 412 0 1 6 PERMIT/PLAN CHECK NUMBER V"V 'D I
TYPE: ❑COMMERCIAL ❑RESIDENTIAL ❑MULTI-FAMILY ❑MOBILE HOME ❑POOL/SPA []SIGN
SUBTYPE: ❑✓ ADDITION [—]ALTERATION []DEMOLITION ❑ELECTRICAL ❑MECHANICAL
❑NEW ❑PLUMBING [—IRE-ROOF-NUMBER OF SQUARES
DESCRIPTION OF WORK Solar Permit-Plan 2785-3.18kW/12 PCS
Master Solar Permit Number:PMT14-02630
PROJECT ADDRESS 30119 Muldands Drive, Menifee, CA 92584
ASSESSOR'S PARCEL NUMBER 3C y -37n -(XC LOT 166 TRAM 30422-3
PROPERTY OWNER'S NAME Lennar Homes of California, Inc.
ADDRESS 980 Montecito Dr.,Suite 302,Corona, CA 92879
PHONE (951)817-3680 EMAIL jeremiah.acayturri@lennar.com
APPLICANT NAME Lennar Homes of California, Inc.
ADDRESS 980 Montecito Dr., Suite 302, Corona, CA 92584
PHONE (951)817-3680 EMAIL jeremiah.acaytur i@lennar.com
CONTRACTOR'S NAME Lennar Homes of California, Inc. OWNER BUILDER? ❑✓ YES❑NO
BUSINESS NAME Lennar Homes of California, Inc.
ADDRESS 980 Montecito Dr.,Suite 302, Corona, CA 92584
PHONE (951)817-3680 EMAIL jeremiah.acayturri@lennar.com
CONTRACTOR'S STATE LIC NUMBER 728102 LICENSE CLASSIFICATION A&B
VALUATION$ $8,331.60 SO FT L SQ FT
APPLICANT'S SIGNATURE DATE 04/04/2016
DEPARTMENT DISTRIBUTION J;th CITY OF MENIFEE BUSINESS LICENSE NUMBER
BUILDING PLANNING ENGINEERING FIRE GREEN ' SMIP
INVOICE ;k j •b PAID AMOUNT
AMOUNT OCASH OCHECK# OCREOIT CARD VISA/MC
:OWNPLAN CHECK FEES PAID AMOUNT O CASH O CHECK# O CREDITCARD VISA/MC
ER VERIFIED O YES O NO DL NUMBER NOTARIZED LETTER O YES O NO
City of Menifee Building&Safety Department 29714 Haun Rd. Menifee, CA 92586 951-672-6777
www.cityofinenifee.us Inspection Request Line 951-246-6213
SYSTEM INFORMATION BUYER ACKNOWLEDGES THAT THE SOLAR MODULES TO BE INSTALLED
ITEM OTY MFR. MODEL ON THE ROOF OF THE HOME WILL BE SUBSTANTIALLY IN THE
SYSTEM SIZE 3.18 KW LOCATIONS INDICATED BY THE ILLUSTRATION.
MODULE 12 PCS.1 HYUNDAI I HIS-S265RG(265W) BUYER:
INVERTER 12 PCS.1 ENPHASE I M215-60-2LL-S22-IG
ROOF TYPE TILE W/COMPOSITE SHINGLE UNDER ARRAY DATE:
SUB-ARRAY INFORMATION
ARRAY#1 ARRAY#2 ARRAY#3
MOD OTY 4 8 NA BUYER:
TILT 1 23- 23' 1 NA'
AZIMUTH 1 115° 205' 1 NA' DATE:
I la
A1u Jo WIS yPJapaf 941 fo SUOISIAa
ue io'Jo;iiwrd a aq of pawlsuoo aq
City of Menifee
Building Dept 31t10
APR 19 20ra
Received
1N3wMIJ30 All
SOLADECK
a i
P
I
V'
Z 1
Q LL ♦ i -
O.
N O
N 1
TRANSITION
WIRE _
TRANSITION IRE
(UNDER ARRAY)
PV AC DISCONNECT
EXTERIOR-GARAGE
UTILITY METER 8 O
MAIN SERVICE PANEL
(VERIFIED BY BUILDER) q1,
Wu+ 6'-6'ARRAY ,
14'-7- T-4'FLASHING
.ar+
NOTE: DIMENSIONS ARE SHOWN IN PLANE OF ROOF
PLAN 2785 ELEVATION A
ORIENTATION I LOT#I66
LENNAR: ORIGINAL BY: JIM PARKS DATE:16.01.20
CAMELLIA AT 980 MONTECITO DRIVE,#302 REVIEWED BY:TOM FIDDES DATE:16. 11.21
THE LAKES CORONA, CA 92879 REV.# BY DATE DESCRIPTION
Va namasGe
SOLAR
DWG TITLE: PAGE#: SCALE: SITE LOCATION: 4571 Broadway Street
INDIVIDUAL 30119 MUIRLANDS DRIVE Boulder,CO 803D4
PLOT PLAN 1 1/16'= 1'-0' MENIFEE,CA 303.447.0300
SYSTEM LAYOUT
MODULE SPECS AND CALCULATIONS INVERTER SPECS AND CALCULATIONS
ITEM NOTE/CALC UNIT DETAIL ITEM NOTE /CALC I UNIT DETAIL
LOCATION MENIFEE,CA INV. MAKE INVERTER SPEC ENPHASE
TEMP,AMBIENT HIGH(TMAX) ASHRAE 2% °C 37 INV. MODEL INVERTER SPEC M215-60-ZLL-S22-IG
TEMP,AMBIENT LOW(THIN) ASHRAE EXTR.MIN °C -2 INV.MAX POWER,(WAC MAX) INVERTER SPEC WATTS(AD) 225
TEMP.MODULE TEST(TTEST) MODULE SPEC oC 25 INV. INPUT V, (VDC MAX) INVERTER SPEC VOLTS 00 48
TEMP,DELTA LOW(TDELTA) THiN-TTEST °C -27 INV. OUTPUT V, (VAC NOM) INVERTER SPEC VOLTS(AC) 240
MOD. MANUFACTURER MODULE SPEC HYUNDAI INV. OUTPUT FREQUENCY INVERTER SPEC HERTZ 60
MOD.PART NUMBER MODULE SPEC HIS-S265RG INV. OUTPUT CURRENT.IAC INVERTER SPEC AMPS(AO) 0.9
MOD. POWER ETC(P) MODULE SPEC WATTS(DO 265 INV. PHASE QUANTITY INVERTER SPEC PHASE I
MOD.POWER PTC MODULE SPEC WATTS(cc) 238 COMPLIANCE INVERTER SPEC UL1741/IEEE1547
MOD. OPERATING VOLTAGE(VMP) MODULE SPEC VOLTS(DO) 31.30 INV. GROUNDING INVERTER SPEC ISOLATED
MOD. OPEN CCT. VOLTAGE(Voc) MODULE SPEC VOLTS(cc) 38AO INV. OTY,MAX/BRANCH CCT. INV.QTYBC QTY 12
MOD. COEFF.VOLT/TEMP(COEF) MODULE SPEC V/°C -0.114 BRANCH CCT. OUTPUT,IMAx8c I (IAc'INV.QTY8C) AMPS(AC) 10.80
MOD. MAX VOLTAGE(VMAXMOD) (Voc+(TD•COEF)) VOLTS(DO 41.18 INV. QUANTITY, TOTAL I INV.GTYT OTY 12
MOD. OPERATING CURRENT(IMP) MODULE SPEC AMPS(cc) 8.50 TOTAL SYSTEM OUTPUT,IMAXTs (IAC•INV.OTYT) AMPS(AC) 10.80
MOD.SHORT CCT. CURRENT 05c) MODULE SPEC AMPS(cc) 9.00
MOD. MAXIMUM CURRENT(IMAX) (Isc• 1.25) AMPS(cc) 11.25
MIN.AMPACITY REO'O,PER NEC (IMAX o 1.25) AMPS(cc) 14.06
SERIES FUSE RATING,MAX MODULE SPEC AMPS(cc) IS
ELECTRICAL EQUIPMENT SCHEDULE
KEY OTY MANUFACTURER MODEL NOTES TRADE
1 12 HYUNDAI FBS-S265RG (265W) PV MODULE SOLAR
2 12 ENPHASE M215-60-2LL-S22-IG PV INVERTER SOLAR
3 2 RSTC/SOLADECK 0786-3R5 PV ROOF JUNCTION BOX,NEMA 3R SOLAR
4 1 CUTLER-HAMMER DG221URB PV AC DISCONNECT,NEMA 3R,240V,30A SOLAR
5 1 ENPHASE ENVOY PV DATA MONITOR, 120V SOLAR
6 1 TBD TBD 120V DEDICATED RECEPTACLE FOR ENVOY PV DATA MONITOR SOLAR
7 1 TBD TBD CATS PORT FOR SOLAR PV INTERNET CONNECTION TO HOME NETWORK BOX SOLAR
8 NOTE CUTLER-HAMMER TBD PV BRANCH CIRCUIT BREAKERS; I x 15A-IP (ENVOY) SOLAR
9 NOTE CUTLER-HAMMER TBD PV BREAKER, I X 20A-2P.LOCATE AT OPPOSITE END OF BUS FROM MAIN BREAKER SOLAR
10 1 TBD TBD SERVICE PANEL,MIN, 125A BUS BLDR. ELEC.
11 1 TBD I TBD I UTILITY METER, PH, 120/24OV,200A BLDR. ELEC.
12 1 TBD I TBD GROUNDING ELECTRODE LIFER BLDR. ELEC.
CONDUCTOR SIZING CALCULATIONS INTERCONNECTION CALCULATIONS
1)CONDITIO OF USE(COU): I (AMPACITY' TEMP. DERATE• FILL DERATE) VS. REO'D(IMAX) ITEM UNIT PANEL
2)JEStOl(TERM): I AMPACITY AT TERMINALS. Vs.REO'D,(IMAX° 1.25) PANEL MFR. CUTLER-HAMMER
KEY SI CU/AL INSULATION CALC. AMPACITY W/O TEMP. FILL RESULT REO'D OCD BUS RATING AMPS 200
TYPE DERATES DERATE DERATE (A) (A) USED(A) MAIN DISCONNECT AMPS 200
A CU THWN-2 COU 30 0.76 1.0 22.80 10.80 ALLOWED PV PER NEC AMPS 40
TERM 25 25 13.50 20. PV OCPD DEVICE USED AMPS 20
B #10. CU NM-8 COU 40 0.91 1.0 36.40 10.80
TERM 35 35 13.50 20
C #10 CU NM-B COU 40 0.91 1.0 36.40 10.80
TERM 35 35 13.50 20
C TOR SCHEDULE
KEAjj0jVDUCTORS 1 CU/AL I TYPE I LOCATION TRADE
A 2 ENGAGE CABLE, 1-#6G,FREE AIR CU TC-ER ARRAY SOLAR
B #10. I-#10 EGC I CU I NM-B(ROMEX) I INTERIOR SOLAR
C 10, I-#10 EGC CU NM-8(ROMEX) INTERIOR SOLAR
D T5E, ETHERNET CABLE CU CATSE INTERIOR SOLAR
5 6 11
7 • o p
O
0 O SEE NOTE 15 IO
0 0
ISA/IP
G O
20A/2P
_. .,f L-
IN
1 A B I C = 12 1
ROOF EXTERIOR-GARAGE
ELECTRICAL DIAGRAM 3.18 KW
LOT#166
LENNAR: ORIGINAL BY: JIM PARKS DATE:16.01.20
CAMELLIA AT
980 MONTECITO DRIVE,#302 REVIEWED BY:TOM FIDDES DATE:16.01.21
THE LAKES CORONA,CA 92879 REV.# BY DATE DESCRIPTION •�
namasbe
so1Ae
DWG TITLE: PAGE#: SCALE: SITE LOCATION: 4571 Broadway Street
INDIVIDUAL 30119 MUIRLANDS DRIVE Boulder,CO 80304
PLOT PLAN 2 NTS MENIFEE,CA 303A47.0300
ELECTRICAL
STRUCTURAL NOTES:
SOLAR CONTRACTOR-
S ALL PV ROOF ATTACHMENTS WILL BE SPACED ALONG MODULE RACKING RAILS AT NOT GREATER THAN 48'O.C.
2)ALL PV ROOF ATTACHMENTS WILL BE STAGGERED BY ROW AMONGST THE ROOF FRAMING MEMBERS,TO MAXIMUM EXTENT POSSIBLE.
3)ROOF PENETRATIONS ASSOCIATED WITH SOLAR RACKING WILL BE SEALED WITH AN APPROVED SEALANT.
4)SOLADECK WIRE TRANSITION BOX WILL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS. IT WILL BE FLASHED AND SEALED.
5)PV ARRAY WILL BE A MINIMUM OF 3"ABOVE THE COMPOSITE SHINGLE ROOF SURFACE.
6)THE UNIRAC SOLARMOUNT RACKING SYSTEM AND SOLAR PV ARRAY WILL BE INSTALLED ACCORDING TO THE UNIRAC SOLARMOUNT CODE-COMPLIANT INSTALLATION
MANUAL,VERSION 227.3,PUB 140113-ICC,JANUARY 2014.
7)UNIRAC TOP CLAMPS REQUIRE A ONE INCH 00 SPACE BETWEEN PV MODULES. SOLARMOUNT RAILS MUST EXTEND A MINIMUM OF TWO INCHES(f+PwAi81971&UAasG0I
OF THE PV ARRAY/SUB-ARRAY. 1 •Sa7UeU�PJO Plle SUOI�e�UEdl
8)UNIRAC SOLARMOUNT REQUIRES THAT A THERMAL EXPANSION GAP BE INSTALLED FOR ANY RAIL LENGTH OF GREATER THAN 40'.
ROOFING CONTRACTOR- 2 j0 U0112101A AUe IJO Jeno)dde
U DISTANCE BETWEEN ARRAY EDGE AND TRANSITION FLASHING(COMPOSITION TO TILE)WILL BE A MINIMUM OF 3'. 'COS sued asagW Ienaddy,
2)26 GAUGE INTERLOCKING FLASHING'SIDEWALL•TO BE INSTALLED ALONG THE LENGTH OF THE PV ARRAY AT ROOFING MATERIAL TRANSITIOON. I SHALL
APROVED PRIOR TO PV SYSTEM INSTALLATION.
3)PEEL-N-STICK BASE TO BE INSTALLED ONE FOOT(P)OR MORE BEYOND THE EDGE OF THE COMPOSITION SHINGLE,DOWN TO THE ROOF EAVE. PEEL-N-STICK BASE TO
BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS.
4)AREAS UNDER EACH PV ARRAY SHALL BE ROOFED WITH COMPOSITION SHINGLE. COMPOSITION SHINGLE SHALL RUN FROM ABOVE THE P JARRAYr ji ZffM jtA_y
5)TILE INSTALLED BELOW THE ARRAY TO BE INSTALLED ABOVE THE COMPOSITION ROOF PER ROOFER SPECIFICATIONS. 1% j,�lY, 1
6)BIRDSTOP WILL BE INSTALLED AT THE UPPERMOST TRANSITION FROM TILE TO COMPOSITION SHINGLE.BIRDSTOP TO BE SPECIFIED BY ROOFER PRIOR TO
INSTALLATION.
dAOad+dV NVI
ONV E (III(IF
ELECTRICAL NOTES:
GENERAL-
0 ALL PV EQUIPMENT WILL BE TESTED AND LISTED FOR ITS USE BY A NATIONALLY RECOGNIZED TESTING LABORATORY(NRTL).
2)THE GROUNDING OF THE PHOTOVOLTAIC SYSTEM SHALL COMPLY WITH THE APPLICABLE VERSION OF THE NEC/CEC.
3)ALL GROUNDING ELECTRODE CONDUCTORS WILL BE INSTALLED IN A CONTINUOUS LENGTH EXCEPT WHERE SPLICED BY AN IRREVERSIBLE CONNECTOR OR EXOTHERMIC
WELD.
4)NON-CURRENT CARRYING METAL PARTS SHALL BE CHECKED FOR PROPER GROUNDING,NOTING THAT TERMINAL LUGS BOLTED ON AN ENCLOSURE'S FINISHED SURFACE
MAY BE ELECTRICALLY INSULATED BECAUSE OF PAINT/FINISH. PAINT/FINISH AT POINT OF CONTACT SHALL BE PROPERLY REMOVED.
5)ROOF PENETRATIONS WILL BE COMPLETED AND SEALED PER APPLICABLE CODE.
6)ALL CONDUCTORS WILL HAVE A 90°C RATING TO ENSURE CODE COMPLIANCE.
SOLAR CONTRACTOR-
7)MODULE CERTIFICATIONS WILL INCLUDE UL1703, IEC61646, IEC61730.
8)CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS.
9)RACEWAY POINT OF PENETRATION FROM EXTERIOR TO INTERIOR WILL BE SEALED TO PREVENT INGRESS OF WATER AND INSECTS.
10)DC WIRING IS LIMITED TO PV ARRAY FOOTPRINT W/ENPHASE MICRO-INVERTER SYSTEM.
11)MODULE AND ENPHASE WIRING SHALL BE LOCATED AND SECURED UNDER THE ARRAY USING SUITABLE WIRING CLIPS. WIRING SHALL NOT MAKE CONTACT WITH THE
ROOF SURFACE AND SHALL BE MANAGED IN A WORKMAN-LIKE MANNER.
12)EQUIPMENT GROUNDING CONDUCTORS WILL BE SIZED IN ACCORDANCE WITH NEC TABLE 250.122.
13)CONDUCTOR TERMINATIONS WILL BE TORQUED PER DEVICE LISTING,OR MANUFACTURER'S RECOMMENDATIONS.
14)A PV AGGREGATION PANEL(SUB PANEL)WILL NOT BE INCLUDED FOR SYSTEMS WITH ONE BRANCH CIRCUIT.
15)A DEDICATED 120V BRANCH CIRCUIT IS REQUIRED IN MASTER CLOSET(OR EQUIVALENT)FOR ENPHASE ENVOY MONITOR.
SIGNAGE-
I6)PV SYSTEMS SHALL BE CLEARLY MARKED IN ACCORDANCE WITH NEC ARTICLE 690 AND OTHER APPLICABLE STATE AND LOCAL CODES,
17)ALL SAFETY MARKING/PLACARDS SHALL BE PERMANENTLY ATTACHED BY ADHESIVE OR OTHER MECHANICAL MEANS.
18)MARKING /PLACARDS WILL BE METAL OR PLASTIC WITH ENGRAVED OR MACHINE PRINTED LETTERING.BACKGROUND WILL BE RED WITH WHITE CAPITAL LETTERING OF
MINIMUM HEIGHT ?.
19)ALL WIRING/RACEWAYS/JUNCTION BOXES WILL BE MARKED-PHOTOVOLTAIC POWER SOURCE;OR EQUIVALENT;WIRING/RACEWAYS SHALL BE MARKED EVERY 10'.
BUILDER ELECTRICAL AND SOLAR CONTRACTORS-
20)INSTALLATION SHALL BE COMPLETED IN A NEAT AND WORKMAN-LIKE MANNER.
21)SPACE REQUIREMENTS FOR ALL ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110.26.
LENNAR: ORIGINAL BY: JIM PARKS DATE:16.01.20
CAMELLIA AT REVIEWED BY: TOM FIDDES DATE:16.01.21
CORONA.CA MONTECI9 87TO 91VE,#302 REV.# BY DATE DESCRIPTION •,
THE LAKES �namaste
SOLAR
DWG TITLE: PAGE#: SCALE: SITE LOCATION:
treet
PINDIVIDUAL 4571 Ber,CO 304
PLOT PLAN 3 NTS 30119 MUIRLANDS DRIVE Boulder,CO 80304
NOTES MENIFEE,CA 303."7.0300
CAUTION:
POWER TO THIS BUILDING IS SUPPLIED BY THE
UTILITY AND A SOLAR PV SYSTEM. DISCONNECTS
ARE LOCATED AS SHOWN.
SOLADECK WIRE
TRANSITION BOX
(UNDER ARRAY)
PV AC DISCONNECT
EXTERIOR-GARAGE
UTILITY METER 8
MAIN SERVICE PANEL
(VERIFIED BY BUILDER)
SERVICE BY QUALIFIED PERSONNEL ONLY
CONTACT: SUNSTREET ENERGY GROUP
I-877-SLR-POWR
PV POWER SOURCE - AC SPECS
AC OPERATING VOLTAGE: 240 V
AC OPERATING CURRENT: 10.8 A
NOTE: SEE MASTER SET FOR ADDITIONAL PLACARD INFORMATION
ORIGINAL BY: JIM PARKS I DATE:16.01.20
CAMELLIA AT LENNAR:
980 MONTECITO DRIVE, #302 REVIEWED BY: TOM FIDDES I DATE:16.01.21
THE LAKES CORONA, CA 92879 REV.# BY DATE DESCRIPTION
`la namasGe
SOLnR
DWG TITLE: PAGE #: I SCALE: SITE LOCATION: 4571 Broadway Street
INDIVIDUAL 30119 MUIRLANDS DRIVE Boulder,C080304
PLOT PLAN A NTS MENIFEE,CA 303.447.0300
PLACARDS