Loading...
PMT16-01176 City of Menifee Permit No.: PMT16-01 VIS _ _ 29714 HAUN RD. Type: Residential Electrical <-�CCEL/? MENIFEE,CA 92586 MENIFEE Date Issued: 04/27/2016 PERMIT Site Address: 29728 FALMER CT, MENIFEE,CA 92584 Parcel Number: 364-370-013 Construction Cost: $6,943.00 Existing Use: Proposed Use: Description of SOLAR TR 30422-3 CAMELLIA Work: 10 MODULES 2.65KW LOT 102 Owner Contractor LENNAR HOMES OF CA LENNAR HOMES OF CALIFORNIA INC 980 MONTECITO DR#302 25 ENTERPRISE CORONA,CA 92879 ALISO VIEJO, CA 92656 Applicant Phone:9493498269 JEREMIAH ACAYTURRI License Number: 728102 LENNAR HOMES OF CALIFORNIA INC 25 ENTERPRISE ALISO VIEJO, CA 92656 Fee Description g.ltt Amount r5l Solar, Residential or Small Commercial 1 252.00 Building Permit Issuance 1 27.00 GREEN FEE 1 1.00 SMIP RESIDENTIAL 1 1.00 General Plan Maintenance Fee-Electrical 1 12.60 $293.60 The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and specifications or from preventing builiding operations being carded on thereunder when in violation of the Building Code or of any other ordinance of City of Menifee.Except as otherwise stated,a permit for construction under which no work is commenced within six months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be forfeited. AA_Bldg_Pennit Template.rpt Page 1 of 1 CITY OF MENIFEE LICENSED DECLARATION property who builds or improves thereon,and who contracts for the projects with a licensed contractor(s)pursuant to the Contractors State License Law). I hereby affirm under penalty of perjury that 1 am under provisions of Chapter9(commencing with section 7000)of Division 3 of the Business and ❑I am exempt from licensure under the Contractor's State License Law for Professions Code and my license is in full force and effect. the following reason: License Class License No. By my signature below I acknowledge that,except for my personal residence Expires Signature in which I must have resided for at least one year prior to completion of improvements covered by this permit.I cannot legally sell a structure that I WORKER'S COMPENSATION DECLARATION have built as an owner-builder if it has not been constructed in its entirety by ❑I hereby affirm under penalty of perjury one of the following declarations:I licensed contractors.I understand that a copy of the applicable law,Section have and will maintain a certificate of consent of self-insure for worker's 7044 of the Business and Professions Code,is available upon request when. compensation,issued by the Director of Industrial Relations as provided for this application is submitted or at the following website: by Section 3700 of the Labor Code,for the performance of work for which wwwleeinfo.ca.gov/calaw.htmL this permit is issued. Policy# PROPERTY OWNER OR AUTHORIZED AGENT Date ❑I have and will maintain worker's compensation insurance,as required by section 3700 of the Labor Code,for the performance of the work for which ❑By my signature below I certify to each of the following:I am the property this permit is issued.My worker's compensation insurance carrier and policy owner or authorized to act on the property owner's behalf.I have read this number are: application and the information I have provided is correct.I agree to comply with all applicable city and county ordinances and state laws relating to Carrier building construction.I authorize representatives of this city or county to Policy# Expires enter the above identified property for inspection purposes. (This section need not to be completed Is the permit is for one-hundred Date dollars($100)or less PROPERTY OWNER OR AUTHORIZED AGENT ❑I certify that in the performance of the work for which this permit is issued, I shall not employ any persons in any manner so as to become subject to the CITY BUSINESS LICENSE# worker's compensation laws of California,and agree that if I should become HAZARDOUS MATERIAL DECLARATION subject to the worker's compensation provisions of Section 3700 of the Labor Code,I shall forthwith comply with those provisions. Will the applicant orfuture building occupant handle hazardous material or a mixture containing a hazardous material equal to or greaterthatthe Applicant Date amounts specified on the Hazardous Materials Information Guide? WARNING:FAILURE TO SECURE WORKER'S COMPENSATION COVERAGE 15 ❑yes ❑No UNLAWFUL,AND SHALL SUB1ECf AN EMPLOYER TO CRIMINAL PENALTIES Will the intended use of the building by the applicant or future building AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS($100,000),IN occupant require a permit for the construction or modification from South ADDITION TO THE COST OF COMPENSATION,DAMAGES AS PROVIDED FOR Coast Air Quality Management District(SCAQMD)?See permitting checklist IN SECTION 3706 OF THE LABOR CODE,INTEREST,AND ATTORNEYS FEES for guidelines CONSTRUCTION LENDING AGENCY ❑Yes ❑No I hereby affirm that under the penalty of perjury there is a construction Will the proposed building or modified facility be within 1000 feet of the lending agency for the performance of the work which this permit is issued outer boundary of a school? (Section 3097 Civil Code) ❑Yes ❑No OWNER BUILDER DECLARATIONS I have read the Hazardous Material Information Guide and the SCAQMD permitting checklist.I understand my requirements under the State of I hereby affirm under penalty of perjury that I am exempt from the California Health&Safety Code,section 25505 and 25534 concerning Contractor's License Law for the reason(s)indicated below by the hazardous material reporting. checkmark(s)I have placed next to the applicable items)(Section 7031.5 oYes ❑No Business and Professions Code).Any city or county that requires a permit to Date construct,alter,improve,demolish or repair any structure,prior to its PROPERTY OWNER OR AUTHORIZED AGENT issuance,also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State EPA RENOVATION REPAIR AND PAINTING(RRP) License Law(Chapter 9(commencing with Section 7000)of Division 3 of the The EPA Renovation,Repair and Painting(RRP)Rule requires contractors Business and Professions Code)or that he or she is exempt from licensure receiving compensation for most work that disturbs paint in a pre-1978 and the basis for the alleged exemption.Any violation of Section 7031.5 by residence or childcare facility to be RRP-certified firms and comply with an Applicant for a permit subjects the applicant to a civil penalty of not more required practices.This includes rental property owners and property than($50D). managers who do the paint-disturbing work themselves or through their ❑I,as owner of the property,or my employee with wages as their sole employees.For more information about EPA's Renovation Program visit: compensation,will do( )all of or( )portion of the work,and the structure is www.epa.eov/lead or contact the National Lead Information Center at not intended or offered for sale.(Section 7044,Business and Professions 1-800-424-LEAD(5323). Code;The Contractors State License Law does not apply to an owner of a ❑An EPA Lead-Safe Certified Renovator will be responsible for this project property who,through employees'or personal effort,builds or improves the property provided that the improvements are not intended or offered for Certified Firm Name: sale.If,however,the building or improvement is sold within one year of Firm Certification No.: completion,the Owner-Builder will have the burden of proving that it was not built or improved for the purpose of sale. ❑No EPA Lead-Safe Certified Firm is required for this project because: ❑I,as owner of the property am exclusively contracting with licensed contractors to construct the project(Section 7044,Business and Professions Code:The Contractor's State License Law does not apply to an owner of a If your project does not comply with EPA RRP rule please fill out the RRP Acknowledgement. ABUILDING & SAFETY PERMIT/PLAN CHECK PPLICATION "Menifee DATE 04/04/2016 PERMIT/PLAN CHECK NUMBER TYPE: []COMMERCIAL ❑✓ RESIDENTIAL ❑MULTI-FAMILY ❑MOBILE HOME ❑POOL/SPA ❑SIGN SUBTYPE: ❑✓ ADDITION []ALTERATION [-]DEMOLITION [-]ELECTRICAL []MECHANICAL [:]NEW []PLUMBING [:IRE-ROOF-NUMBER OF SQUARES DESCRIPTION OF WORK Solar Permit-Plan 2077-2.65kW/10 PCS Master Solar Permit Number.PMT14-02630 PROJECT ADDRESS 29728 Falmer Ct, Menifee, CA 92584 ASSESSOR'S PARCEL NUMBER �L4- 37(- — 013 LOT 102 TRACT 30422-3 PROPERTY OWNER'S NAME Lennar Homes of California, Inc. ADDRESS 980 Montecito Dr.,Suite 302,Corona,CA 92879 PHONE (951)817-3680 EMAIL jeremiah.acayturri@lennar.com APPLICANT NAME Lennar Homes of California, Inc. ADDRESS 980 Montecito Dr.,Suite 302, Corona,CA 92584 PHONE (951)817-3680 EMAIL jeremiah.acayturri@lennor.com CONTRACTOR'S NAME Lennar Homes of California, Inc. OWNER BUILDER? ❑✓ YES❑NO BUSINESS NAME Lennar Homes of California, Inc. ADDRESS 980 Montecito Dr.,Suite 302, Corona,CA 92584 PHONE (951)817-3680 EMAIL jeremiah.acayturri@lennar.com CONTRACTOR'S STATE LIC NUMBER 728102 LICENSE CLASSIFICATION A&B VALUATION$ $6,943.00 SQ APPLICANT'S SIGNATURE DATE 04/04/2016 CITYSTAFF USE ONLY wlr� DEPARTMENT DISTRIBUTION � I CITY OF MENIFEE BUSINESS LICENSE NUMBER BUILDING PLANNING ENGINEERING FIRE GREEN (!" SMIP INVOICE �MyjbPAID AMOUNT AMOUNT C CASH C CHECK# C CREDITCARD VISA/MC PLAN CHECK FEES PAIDAMOUNT OCASH OCHECK# OCREDITCARD VISA/MC OWNER BUILDER VERIFIED OYES C NO DL NUMBER NOTARIZED LETTER C YES C NO City of Menifee Building&Safety Department 29714 Haun Rd. Menifee, CA 92586 951-672-6777 www.cityofinenifee.us Inspection Request Line 951-246-6213 SYSTEM INFORMATION BUYER ACKNOWLEDGES THAT THE SOLAR MODULES.TO BE INSTALLED ITEM OTY 1 MFR. 1 MODEL ON THE ROOF OF THE HOME WILL BE SUBSTANTIALLY IN THE SYSTEM SIZE 2.65 KW LOCATIONS INDICATED BY THE ILLUSTRATION. MO DULE 10 PCS. HYUNDAI I HIS-S265RG(265W) BUYER: INVERTER IO PCS.1 ENPHASE I M215-60-2LL-S22-IG ROOF TYPE TILE W/COMPOSITE SHINGLE UNDER ARRAY DATE:- SUB-ARRAY INFORMATION ARRAY#I ARRAY#2 ARRAY#3 MOD OTY 10 NA NA BUYER: _ TILT 23° NA- MA- DATE:- - ' .� OFIVIENIFEE AZIMUTH 256° NA- NA° �-t'jI_DING AND SAFE' City of Menifee �'N APPROVAL Building Dept IA Received APR 18 2016 r r 1'VFD 6 [R e c e I v e d ,ro,'4 o`these plans shall not be 20979FLASHING 1%.01/ l Di,any violation of any provi F1,J Jonsandordinances. This seta p to until completion, I I I t I I I I I I I I I SOLADECK WIRE TRANSITION BOX 6 (UNDER ARRAY) `r PV AC DISCONNECT L EXTERIOR-GARAGE 'V LITY METER —J t— ——— _———J MAIN L IN SERVICE PANEL e-e (VERIFIED BY BUILDER) ftg •\y' NOTE:DIMENSIONS ARE SHOWN IN PLANE OF ROOF PLAN 2077 ELEVATION C-REVERSE OW FERN PA'ION I LOT# 102 LENNAR: ORIGINAL BY: DESIREE WILLIAMS DATE:16.3.15 CAMELLIA AT 980 MONTECITO DRIVE,#502 REVIEWED BY:ARTHUR HICKS DATE:16.3.15 THE LAKES CORONA,CA 92879 REV.# BY DATE DESCRIPTION •, `al namaste sOLAe DWG TITLE: PAGE#: SCALE: SITE LOCATION: 4571 Broadway Street INDIVIDUAL 29728 PALMER CT Boulder,GO 80304 PLOT PLAN 1/16'= 1'-0' MENIFEE,CA 303.447.0300 SYSTEM LAYOUT MODULE SPECS AND CALCULATIONS INVERTER SPECS AND CALCULATIONS ITEM NOTE/CALC UNIT DETAIL ITEM NOTE/CALC UNIT DETAIL LOCATION MENIFEE,CA INV. MAKE INVERTER SPEC ENPHASE TEMP,AMBIENT HIGH(TMAx) ASHRAE 2% °C 37 INV. MODEL INVERTER SPEC M215-60-2LL-S22-IG TEMP,AMBIENT LOW(THIN) ASHRAE EXTR.MIN °C -2 INV. MAX POWER, (WAC MAX) INVERTER SPEC WATTS(AC) 225 TEMP,MODULE TEST(TTEST) MODULE SPEC °C 25 INV. INPUT V,(VDC MAX) INVERTER SPEC VOLTS(oc) 4B TEMP,DELTA LOW(TDECTA) THIN-TTEST °C -27 INV. OUTPUT V,(VAc NOM) INVERTER SPEC VOLTS(AC) 240 MOD. MANUFACTURER MODULE SPEC HYUNDAI INV. OUTPUT FREQUENCY INVERTER SPEC HERTZ 60 MOD. PART NUMBER MODULE SPEC HIS-S265RG INV. OUTPUT CURRENT, IAD INVERTER SPEC AMPS(AC) 0.9 MOD, POWER STC(P) MODULE SPEC WATTS(DC) 265 INV. PHASE QUANTITY INVERTER SPEC PHASE I MOD. POWER PTC MODULE SPEC WATTS(DD) 238 COMPLIANCE INVERTER SPEC UL1741/IEEE1547 MOD. OPERATING VOLTAGE(VMP) MODULE SPEC VOLTS(DC) 31.30. INV. GROUNDING INVERTER SPEC ISOLATED MOD. OPEN CCT.VOLTAGE(Vac) MODULE SPEC VOLTS(130 38.10 INV. OTY, MAX 18 CCT. INV.OTYBc OTY 10 MOD. COEFF.VOLT/TEMP(COEF) MODULE SPEC V/°C -0.114 BRANCH CCT. OUTPUT, IMAXec QAC•INV.QTYBc) I AMPS(AO) 1 9.00 MOD. MAX VOLTAGE(VMAXMOD) (Voc+(Ta-COEF)) VOLTS(oU 41.18 INV. QUANTITY,TOTAL INV-OTYi I OTY 110 MOD. OPERATING CURRENT(IMP) MODULE SPEC AMPS 010 8.50 TOTAL SYSTEM OUTPUT, INAZTS (IAC-INV.QTYT) I AMPS(AC) 1 9.00 MOD. SHORT CCT. CURRENT(Isc) MODULE SPEC AMPS(oc) 9.00 MOD. MAXIMUM CURRENT(IMAX) (Isc.1,25) AMPS(nc) 11.25 MIN. AMPACITY REO'D.PER NEC (IMAX- 1.25) AMPS.(00 14.06. SERIES FUSE RATING,MAX MODULE SPEC AMPS(oc) 15 ELECTRICAL EQUIPMENT SCHEDULE KEY OTY MANUFACTURER MODEL NOTES TRADE I 10 HYUNDAI HIS-S265RG (265W) PV MODULE SOLAR 2 10 ENPHASE M215-60-2LL-S22-IG PV INVERTER SOLAR 3 1 RSTC/SOLADECK 0786-3R5 PV ROOF JUNCTION BOX,NEMA 3R SOLAR 4 1 CUTLER-HAMMER DG221LRB PV AC DISCONNECT.NEMA 3R,240V.30A SOLAR 5 1 ENPHASE ENVOY PV DATA MONITOR, 120V SOLAR 6 1 TBD TBD 120V DEDICATED RECEPTACLE FOR ENVOY PV DATA MONITOR SOLAR 7 1 TBD TBD CATS PORT FOR SOLAR PV INTERNET CONNECTION TO HOME NETWORK BOX SOLAR a NOTE CUTLER-HAMMER TBD PV BRANCH CIRCUIT BREAKERS; I x 15A-IP(ENVOY) SOLAR 9 NOTE CUTLER-HAMMER TBD PV BREAKER, IX 20A-2P,LOCATE AT OPPOSITE END OF BUS FROM MAIN BREAKER SOLAR 10 1 TBD TBD 1 SERVICE PANEL,MIN. 125A BUS BLDR. ELEC. It TBD TBD UTILITY METER, IPH. 120/24OV,200A BLDR. ELEC. I I TBD TBD GROUNDING ELECTRODE UFER BLDR. ELEC. DUCTOR SIZING CALCULATIONS INTERCONNECTION CALCULATIONS J�MNDITION OF USE(COU): (AMPACITY• TEMP. DERATE- FILL DERATE)vs. REO'D(IMAX) ITEM UNIT PANEL 2)TERMINALS(TERM): AMPACITY AT TERMINALS. M. REO'D,(IMAX' 1.25) PANEL MFR. CUTLER-HAMMER K SIZE CU/AL INSULATION CALC. AMPACITY W/O TEMP. FILL RESULT REO'D OCD BUS RATING AMPS 200 TYPE DERATES DERATE DERATE (A) (A) USED(A) MAIN DISCONNECT AMPS 200 A #12 CU THWN-2 COU 30 0.76 1.0 22.80 9.00 ALLOWED PV PER NEC AMPS 40 TERM 25 25 11.25 20 PV OCPD DEVICE USED AMPS 20 B'. #10 CU NM-B COU 40 0.91 1.0 36.40 9.00 TERM 35 35 11.25 "zo C'. #10 CU NM-B COU 40 0.91 1.0 36.40 9.00 TERM 35 35 11.25 NDUCTOR SCHEDULE .KEY CONDUCTORS CU/AL TYPE LOCATION TRADE 1-#12 ENGAGE CABLE, 1-#6G,FREE AIR CU TC-ER ARRAY SOLAR 'B 3-#10. I-4M0 EGC CU NM-B(ROMEX) I NTERIOR SOLAR C 3-#10, 1410 EGC CU NM-B(ROMEX) INTERIOR SOLAR Ir O CATSE,ETHERNET CABLE CU CAT5E INTERIOR SOLAR M Lf, 5 6 O_ SEE NOTE 15 10 ISaIIP O O 2002 O h it G G A B C ROOF EXTERIOR-GARAGE ELECTRICAL DIAGRAM 2.65 KW LOT# 102 LENNAR: ORIGINAL BY: DESIREE WILLIAMS DATE:16.3.15 CAMELLIA AT 980 MONTECITO DRIVE,#302 REVIEWED BY:ARTHUR HICKS DATE:16.3.15 THE LAKES CORONA,CA 92879 REV.# BY DATE DESCRIPTION •� namaste SOL R DWG TITLE: PAGE#: SCALE: SITE LOCATION: 4571 Broadway Steel INDIVIDUAL 29728 FALMER CT Boulder,CO 80304 PLOT PLAN 2 NTS MENIFEE,CA 303.447.0300 ELECTRICAL STRUCTURAL NOTES: SOLARCONTRACTOR- n ALL PV ROOF ATTACHMENTS WILL BE SPACED ALONG MODULE RACKING RAILS AT NOT GREATER THAN 48'O.C. 2)ALL PV ROOF ATTACHMENTS WILL BE STAGGERED BY ROW AMONGST THE ROOF FRAMING MEMBERS,TO.MAXIMUM EXTENT POSSIBLE. 3)ROOF PENETRATIONS ASSOCIATED WITH SOLAR RACKING WILL BE SEALED WITH AN APPROVED SEALANT. 4)SOLADECK WIRE TRANSITION BOX WILL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS. IT WILL BE FLASHED AND SEALED. 5)PV ARRAY WILL BE A MINIMUM OF 3'A80VE THE COMPOSITE SHINGLE ROOF SURFACE. 6)THE UNIRAC SOLARMOUNT RACKING SYSTEM AND SOLAR PV ARRAY WILL BE INSTALLED ACCORDING TO THE UNIRAC SOLARMOUNT CODE-COMPLIANT INSTALLATION MANUAL,VERSION 227.3, PUB 1401I3-ICC,JANUARY 2014. 7)UNIRAC TOP CLAMPS REQUIRE A ONE INCH(I')SPACE BETWEEN PV MODULES. SOLARMOUNT RAILS MUST EXTEND A MINIMUM OF TWO INCHES(21)BEYOND THE EDGE OF THE PV ARRAY/SUB-ARRAY. 8)UNIRAC SOLARMOUNT REQUIRES THAT A THERMAL EXPANSION GAP BE INSTALLED FOR ANY RAIL LENGTH OF GREATER THAN 40'. . DEPARTMENT ROOFING CONTRACTOR- 1)DISTANCE BETWEEN ARRAY EDGE AND TRANSITION FLASHING (COMPOSITION TO TILE)WILL BE A MINIMUM OF 3% 2)26 GAUGE INTERLOCKING FLASHING'SIDEWALL'TO BE INSTALLED ALONG THE LENGTH OF THE PV ARRAY AT ROOFING MATERIAL TRANSITION. IT SHALL BE APROVED PRIOR TO PV SYSTEM INSTALLATION. 3)PEEL-N-STICK BASE TO BE INSTALLED ONE FOOT W)OR MORE BEYOND THE EDGE OF THE COMPOSITION SHINGLE,DOWN TO THE ROOFS AV PEEL-N- ICK AS 0 BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS. 4)AREAS UNDER EACH PV ARRAY SHALL BE ROOFED WITH COMPOSITION SHINGLE. COMPOSITION SHINGLE SHALL RUN FROM ABOVE THE( RO I/ 5)TILE INSTALLED BELOW THE ARRAY TO BE INSTALLED ABOVE THE COMPOSITION ROOF PER ROOFER SPECIFICATIONS. - 6)BIRDSTOP WILL BE INSTALLED AT THE UPPERMOST TRANSITION FROM TILE TO COMPOSITION SHINGLE.BIRDSTOP TO BE SPECIFIED BY OOFER PRIOR TO DATE INSTALLATION. )to`e a permit for,or an f the federal,state or dty Oved pans must be kept on the ELECTRICAL NOTES: GENERAL- 1)ALL PV EQUIPMENT WILL BE TESTED AND LISTED FOR ITS USE BY A NATIONALLY RECOGNIZED TESTING LABORATORY(NRTL). 2)THE GROUNDING OF THE PHOTOVOLTAIC SYSTEM SHALL COMPLY WITH THE APPLICABLE VERSION OF THE NEC/CEC. 3)ALL GROUNDING ELECTRODE CONDUCTORS WILL BE INSTALLED IN A CONTINUOUS LENGTH EXCEPT WHERE SPLICED BY AN IRREVERSIBLE CONNECTOR OR EXOTHERMIC WELD. 4)NON-CURRENT CARRYING METAL PARTS SHALL BE CHECKED FOR PROPER GROUNDING,NOTING THAT TERMINAL LUGS BOLTED ON AN ENCLOSURE'S FINISHED SURFACE MAY BE ELECTRICALLY INSULATED BECAUSE OF PAINT/FINISH. PAINT/FINISH AT POINT OF CONTACT SHALL BE PROPERLY REMOVED. 5)ROOF PENETRATIONS WILL BE COMPLETED AND SEALED PER APPLICABLE CODE. 6)ALL CONDUCTORS WILL HAVE A 90'C RATING TO ENSURE CODE COMPLIANCE. SOLAR CONTRACTOR- 7)MODULE CERTIFICATIONS WILL INCLUDE UL1703, IEC61646, IEC61730. 8)CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS. 9)RACEWAY POINT OF PENETRATION FROM EXTERIOR TO INTERIOR WILL BE SEALED TO PREVENT INGRESS OF WATER AND INSECTS. 10)DC WIRING IS LIMITED TO PV ARRAY FOOTPRINT W/ENPHASE MICRO-INVERTER SYSTEM. ID MODULE AND ENPHASE WIRING SHALL BE LOCATED AND SECURED UNDER THE ARRAY USING SUITABLE WIRING CLIPS. WIRING SHALL NOT MAKE CONTACT WITH THE ROOF SURFACE AND SHALL BE MANAGED IN A WORKMAN-LIKE MANNER. 12)EQUIPMENT GROUNDING CONDUCTORS WILL BE SIZED IN ACCORDANCE WITH NEC TABLE 250.122. 13)CONDUCTOR TERMINATIONS WILL BE TORQUED PER DEVICE LISTING,OR MANUFACTURER'S RECOMMENDATIONS. 14)A PV AGGREGATION PANEL(SUB PANEL)WILL NOT BE INCLUDED FOR SYSTEMS WITH ONE BRANCH CIRCUIT. 15)A DEDICATED 120V BRANCH CIRCUIT IS REQUIRED IN MASTER CLOSET(OR EQUIVALENT)FOR ENPHASE ENVOY MONITOR. SIGNAGE- 16)PV SYSTEMS SHALL BE CLEARLY MARKED IN ACCORDANCE WITH NEC ARTICLE 690 AND OTHER APPLICABLE STATE AND LOCAL CODES. 17)ALL SAFETY MARKING /PLACARDS SHALL BE PERMANENTLY ATTACHED BY ADHESIVE OR OTHER MECHANICAL MEANS. 18)MARKING /PLACARDS WILL BE METAL OR PLASTIC WITH ENGRAVED OR MACHINE PRINTED LETTERING. BACKGROUND WILL BE RED WITH WHITE CAPITAL LETTERING OF MINIMUM HEIGHT a'. 19)ALL WIRING/RACEWAYS/JUNCTION BOXES WILL BE MARKED'PHOTOVOLTAIC POWER SOURCE,'OR EQUIVALENT:WIRING/RACEWAYS SHALL BE MARKED EVERY 10'. BUILDER ELECTRICAL AND SOLAR CONTRACTORS- 20)INSTALLATION SHALL BE COMPLETED IN A NEAT AND WORKMAN-LIKE MANNER. 21)SPACE REQUIREMENTS FOR ALL ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110.26. LENNAR: ORIGINAL BY: OESIREE WILLIAMS DATE:16.3.15 CAMELLIA AT REVIEWED BY:ARTHUR HICKS DATE:16.3.15 CO NA, CA I92 DRIVE,#302 THE LAKES CORONA, LA 42879 REV.# BY DATE DESCRIPTION `u namast:e SOL�L DWG TITLE: PAGE#: SCALE: SITE LOCATION: 4571 Broadway Street INDIVIDUAL 29728 PALMER CT Boulder,CO 80304 PLOT PLAN 3 NTS M , NOTES 303.447.0300ENIFEE CA CAUTION: POWER TO THIS BUILDING IS SUPPLIED BY THE UTILITY AND A SOLAR PV SYSTEM. DISCONNECTS ARE LOCATED AS SHOWN. SOLME.WIPE TRM511ION BOX OLNOER NNAY) PV AC 0I1L114NOT FXiEPION-OAN.0 UTILITY NEIRN S ..SERYIEE PANEL IY£PI11E0 OY 9111L➢EP) SERVICE BY QUALIFIED PERSONNEL ONLY CONTACT: SUNSTREET ENERGY GROUP 1-877-SLR-POWR PV POWER SOURCE - AC SPECS AC OPERATING VOLTAGE: 240 V AC OPERATING CURRENT: 9.0 A NOTE: SEE MASTER SET FOR ADDITIONAL PLACARD INFORMATION LENNAR: ORIGINAL BY: DESIREE WILLIAMS DATE:16.3.15 CAMELLIA AT 960 MONTECITO DRIVE,#302 REVIEWED BY:ARTHUR HICKS DATE:16.3.15 THE LAKES CORONA,CA 92879 REV.# BY DATE DESCRIPTION �2 maste SOLAR DWG TITLE: PAGE#: SCALE: SITE LOCATION: 4571 Broadmy Street INDIVIDUAL 29728 PALMER CT Boulder,CO 80304 PLOT PLAN 4 NTS MENIFEE,CA 303.447.0300 PLACARDS