Loading...
PMT16-01173 City of Menefee Permit No.: PMT16-01173 29714 HAUN RD.ACCELA? MENIFEE,CA 92586 Type: Residential Electrical MENIFEE Date Issued: 04/27/2016 PERMIT Site Address: 29684 FALMER CT, MENIFEE, CA 92584 Parcel Number: 364-370-010 Construction Cost: $8,331.60 Existing Use: Proposed Use: Description of SOLAR TR 30422-3 CAMELLIA Work: 12 MODULES 3.18 KW LOT 99 Owner Contractor LENNAR HOMES OF CA LENNAR HOMES OF CALIFORNIA INC 980 MONTECITO DR#302 25 ENTERPRISE CORONA,CA 92879 ALISO VIEJO, CA 92656 Applicant Phone: 9493498269 JEREMIAH ACAYTURRI License Number:728102 LENNAR HOMES OF CALIFORNIA INC 25 ENTERPRISE ALISO VIEJO, CA 92656 Fee Description ON Amount lbl Solar, Residential or Small Commercial 1 252.00 Building Permit Issuance 1 27.00 GREEN FEE 1 1.00 SMIP RESIDENTIAL 1 2.00 General Plan Maintenance Fee-Electrical 1 12.60 $294.60 The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and specifications or from preventing builiding operations being carried on thereunder when in violation of the Building Code or of any other ordinance of City of Menifee. Except as otherwise staled,a permit for construction under which no work is commenced within six months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be forfeited. AA_Bldg_Permit_Templatexpt Page 1 of 1 CITY OF MENIFEE LICENSED DECLARATION property who builds or improves thereon,and who contracts for the projects I hereby affirm under penalty of perjury that I am under provisions of with a licensed contractor(s)pursuant to the Contractors State License Law). Chapter9(commencing with section 7000)of Division 3 of the Business and ❑I am exempt from licensure under the Contractors State License Law for Professions Code and my license is in full force and effect. the following reason: License Gass License No. By my signature below I acknowledge that,exceptfor my personal residence Expires Signature in which I must have resided for at least one year prior to completion of improvements covered by this permit.I cannot legally sell a structure that I WORKER'S COMPENSATION DECLARATION have built as an owner-builder if it has not been constructed in its entirety by ❑I hereby affirm under penalty of perjury one of the following declarations:I licensed contractors.I understand that a copy of the applicable law,Section have and will maintain a certificate of consent of self-insure for worker's 7044 of the Business and Professions Code,is available upon request when compensation,issued by the Director of Industrial Relations as provided for this application is submitted or at the following website: by Section 3700 of the Labor Code,for the performance of work for which ,M,ny;leainfo.ca.eov/calaw.html. this permit is issued. Polity It Date PROPERTY OWNER OR AUTHORIZED AGENT ❑I have and will maintain worker's compensation insurance,as required by section 3700 of the Labor Code,for the performance of the work for which ❑By my signature below I certify to each of the following:I am the property this permit is issued.My workers compensation insurance carrier and policy owner or authorized to act on the property owner's behalf.I have read this number are: application and the information I have provided is correct.I agree to comply Cartier with all applicable city and county ordinances and state laws relating to building construction.I authorize representatives of this city or county to Policy M Expires enter the above identified property for inspection purposes. (This section need not to be completed is the permit is for one-hundred Date dollars($100)or less PROPERTY OWNER OR AUTHORIZED AGENT ❑I certifythat in the performance of the work forwhich this permit is issued, I shall not employ any persons in any manner so as to become subject to the CITY BUSINESS LICENSE p worker's compensation laws of California,and agree that if I should become HAZARDOUS MATERIAL DECLARATION subject to the workers compensation provisions of Section 3700 of the Labor Code,I shall forthwith comply with those provisions. Will the applicant or future building occupant handle hazardous material or a Applicant Date mixture containing a hazardous material equal to or greater that the amounts specified on the Hazardous Materials Information Guide. WARNING:FAILURE TO SECURE WORKER'S COMPENSATION COVERAGE 15 ❑yes ❑No UNLAWFUL,AND SHALL SUBIECTAN EMPLOYER TO CRIMINAL PENALTIES Will the intended use of the building by the applicant or future building AND CIVIL FINES UPTO ONE HUNDRED THOUSAND DOLLARS($100,000),IN occupant require a permit for the construction or modification from South ADDITION TO THE COST OF COMPENSATION,DAMAGES AS PROVIDED FOR Coast Air Quality Management District(SCAQMD)?See permitting checklist IN SECTION 3706 OF THE LABOR CODE,INTEREST,AND ATTORNEYS FEES forguidelines CONSTRUCTION LENDING AGENCY OYes ❑No I hereby affirm that under the penalty of perjury there is a construction Will the proposed building or modified facility be within 1000 feet of the lending agency for the performance of the work which this permit is issued outer boundary of a school? (Section 3097 Civil Code) ❑Yes ❑No OWNER BUILDER DECLARATIONS I have read the Hazardous Material Information Guide and the SCAQMD permitting checklist.I understand my requirements under the State of 1 hereby affirm under penalty of perjury that I am exempt from the Californiaealth al Safety Code,Section 25505 and 25534 concerning Contractor h s License Law for the reason(s)indicated below by the hazardous material reporting. checkmark(s)I have placed next to the applicable item(s)(Section 7031.5 Oyes ❑No Business and Professions Code).Any city or county that requires a permit to Date construct,alter,improve,demolish or repair any structure,prior to its PROPERTY OWNER OR AUTHORIZED AGENT issuance,also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractors State EPA RENOVATION.REPAIR AND PAINTING IRRP) License Law(Chapter 9(commencing with Section 7000)of Division 3 of the Business and Professions Code)or that he or she is exemptfrom licensure The EPA Renovation,Repair and Painting(RRP)Rule requires contractors receiving compensation for most work that disturbs paint in a pre-1978 and the basis for the alleged exemption.Any violation of Section 7031.5 by residence or childcare facility to be RRP-certified firms and comply with an Applicant for a permit subjects the applicant to a civil penalty of not more required practices.This includes rental property owners and property than($500). managers who do the paint-disturbing work themselves or through their ❑I,as owner of the property,or my employee with wages as their sole employees.For more information about EPA's Renovation Program visit: compensation,will do( )all of or( )portion of the work,and the structure is www.eoa.gov/lead or contact the National Lead Information Center at not intended or offered for sale.(Section 7044,Business and Professions 1-800-424-LEAD(5323). Code;The Contractors State License Law does not apply to an owner of a ❑An EPA Lead-Safe Certified Renovator will be responsible for this project property who,through employees'or personal effort,builds or improves the property provided that the improvements are not intended or offered for Certified Firm Name: sale.If,however,the building or improvement is sold within one year of Firm Certification No.: completion,the Owner-Builder wl11 have the burden of proving that it was not built or improved for the purpose of sale. ❑No EPA Lead-Safe Certified Firm is required for this project because: ❑I,as owner of the property am exclusively contracting with licensed contractors to construct the project(Section 7044,Business and Professions Code:The Contractors State License Law does not apply to an owner of a If your project does not comply with EPA RRP rule please fill out the RRP Acknowledgement. APPLICATIONBUILDING SAFETY PERMIT/PLAN CHECK Menifee n DATE 0 4/0 412 0 1 6 PERMIT/PLAN CHECK NUMBER D TYPE: ❑COMMERCIAL ❑✓ RESIDENTIAL ❑MULTI-FAMILY ❑MOBILEHOME ❑POOL/SPA ❑SIGN SUBTYPE: ❑✓ ADDITION []ALTERATION ❑DEMOLITION ❑ELECTRICAL ❑MECHANICAL ❑NEW [:]PLUMBING ❑RE-ROOF-NUMBER OF SQUARES DESCRIPTION OF WORK Solar Permit-Plan 2785-3.18kW/12 PCS Master Solar Permit Number: PMT14-02630 PROJECTADDRESS 29684 Falmer/Ct, Menifee,�CA 92584 S ASSESSOR'S PARCEL NUMBER h; �e,/y— n DIn LOT 99 TRACT 30422-3 PROPERTY OWNER'S NAME Lennar Homes of California, Inc. ADDRESS 980 Montecito Dr., Suite 302, Corona,CA 92879 PHONE (951)817-3680 EMAIL jeremiah.acayturri@lennar.com APPLICANT NAME Lerner Homes of California, Inc. ADDRESS 980 Montecito Dr.,Suite 302, Corona,CA 92584 PHONE (951)817-3680 EMAIL leremiah.acayturri@lennar.com CONTRACTOR'S NAME Lennar Homes of California, Inc. OWNER BUILDER? ❑✓ YES❑NO BUSINESS NAME Lerner Homes of California, Inc. ADDRESS 980 Montecito Dr.,Suite 302,Corona,CA 92584 PHONE (951)817-3680 EMAIL Jeremiah.acayturci@lennar.com CONTRACTOR'S STATE LIC NUMBER 728102 LICENSE CLASSIFICATION A&B VALUATION$ $8,331.60 S L SQ Ff APPLICANT'S SIGNATURE DATE 04/04/2016 CITY STAFF USE ONLY DEPARTMENT DISTRIBUTION I� CI T/OF MENIFEE BUSINESS LICENSE NUMBER BUILDING PLANNING ENGINEERING FIRE GREEN SMIP INVOICE PAID AMOUNT AMOUNT •�Po I 1 OCASH 0 CHECK# 0CREDIT CARD VISA/MC PLAN CHECK FEES PAID AMOUNT C CASH C CHECK# C CREDIT CARD VISA/MC OWNER BUILDER VERIFIED O YES O NO DL NUMBER NOTARIZED LETTER O YES C NO City of Menifee Building&Safety Department 29714 Noun Rd. Menifee, CA 92586 951-672-6777 www.cityofinenifee.us Inspection Request Line 951-246-6213 SYSTEM INFORMATION BUYER ACKNOWLEDGES THAT THE SOLAR MODULES TO BE INSTALLED ITEM OTY MFR. MODEL ON THE ROOF OF THE HOME WILL BE SUBSTANTIALLY IN THE SYSTEM SIZE 3.18 KW LOCATIONS INDICATED BY THE ILLUSTRATION. MODULE 12 PCS. HYUNDAI I HIS-S265RG (265W) BUYER: INVERTER 1 12 PCS-1 ENPHASE I M215-60-2LL-S22-IG ROOF TYPE I TILE W/COMPOSITE SHINGLE UNDER ARRAY DATE: SUB-ARRAY INFORMATION ARRAY#1 ARRAY#2 ARRAY#3 MOD OTY 12 NA NA BUYER: TILT 23' NA' NA` City of Menifee AZIMUTH 207° NA' NA' DATE: Building Dept :,J!ILDING AND SAFETY DI APR 18 201E F r.y APPROVAL Received C I r�1.4 plans shali not be ronstn 23'-1"ARRAY 4 u Of,any violation of any provisions a 6'-4Y' 23'-II'FLASHING ne'.ass and ordinances. This set ofappr ' (:ntil rc npletion. I I I I I I I I SOLADELK WIRE TRANSITION BOX � (UNDER ARRAY) _ I V ( PV DISCONNECT EXTERIOR-GARAGE UTILITY METER 8 MAIN SERVICE PANEL J ___ (VERIFIED BY BUILDER) L—_—— Aa rr 0- 0 some NOTE:DIMENSIONS ARE SHOWN IN PLANE OF ROOF ^\ `® PLAN 2785 ELEVATION B-REVERSE ORIENTATION I LUI#99 ORIGINAL BY: DESIREE WILLIAMS DATE:16.3.15 CAMELLIA AT LENNAR: REVIEWED BY:ARTHUR HICKS DATE:16.3.15 THE LAKES 980 NA, CA I92 DRIVE,#302 CORONA, CA 92879 REV.# BY DATE DESCRIPTION ., namast;e DWG TITLE: PAGE #: SCALE: SITE LOCATION: 4571 Broadway Street INDIVIDUAL 29684 FALMER CT Boulder,CO BD304 PLOT PLAN 1 1116'=1'-0' MENIFEE,CA 303.447.0300 SYSTEM LAYOUT MODULE SPECS AND CALCULATIONS INVERTER SPECS AND CALCULATIONS ITEM NOTE /CALC UNIT DETAIL ITEM NOTE/CqSPEC UNIT DETAIL LOCATION MENIFEE,CA INV. MAKE INVERTER ENPHASE TEMP,AMBIENT HIGH(TMAX) ASHRAE 2% °C 37 INV. MODEL INVERTER M215-60-2LL-S22-IG TEMP,AMBIENT LOW(THIN) ASHRAE EXTR.MIN °C -2 INV. MAX POWER, (WAC MAX) INVERTERWATTS(Ac) 225 TEMP,MODULE TEST(TTEST) MODULE SPEC °C 25 INV. INPUT V.(Voc MAX) INVERTERVOLTS(DO 48 TEMP,DELTA LOW(TEELTA) THIN-TTEST °C -27 INV. OUTPUT V, (Vac NOM) INVERTER (AC) 240 MOD. MANUFACTURER MODULE SPEC HYUNDAI INV. OUTPUT FREQUENCY INVERTERHERTZ 60 MOD.PART NUMBER MODULE SPEC HIS-S265RG INV. OUTPUT CURRENT, IAc INVERTERAMPS(AC) 0.9 MOD. POWER STC(P) MODULE SPEC WATTS(M) 265 INV. PHASE QUANTITY INVERTERPHASE I MOD. POWER PTC MODULE SPEC WATTS(DC) 238 COMPLIANCE INVERTER UL1741/IEEEI547 MOD. OPERATING VOLTAGE(VMP) MODULE SPEC VOLTS(DC) 31.30 INV. GROUNDING 1 INVERTER SPEC ISOLATED -MOD. OPEN CCT. VOLTAGE(Vac) MODULE SPEC VOLTS(cc) 38.10 INV. CITY,MAX /BRANCH CCT. INV.QTYBc QTV 12 MOD'. COEFF. VOLT/TEMP(COEF) MODULE SPEC V/°C -0.114 BRANCH CCT. OUTPUT. IMAXBC (IAC-INV.OTYBC) I AMPS CAC) 110.80 MOD. MAX VOLTAGE(VMAXMOO) (Vac+(To-COEF)) VOLTS(cc) 41.18 INV. QUANTITY,TOTAL INV.QTYT QTY 112 MOD. OPERATING CURRENT(imp) MODULE SPEC AMPS(cc) 8.50 TOTAL SYSTEM OUTPUT, IMAXTS (IAC-INV.QTYT) AMPS(AC) 10.80 MOD. SHORT CCT. CURRENT(ISC) MODULE SPEC AMPS(DC) 9.00 MOD. MAXIMUM CURRENT(IMAX) Osc- 1.25) AMPS(DC) 11.25 MIN. AMPACITY REO'D,PER NEC (IMAX' 1,25) AMPS(oc) 14.06 SERIES FUSE RATING,MAX MODULE SPEC AMPS(130 15 ELECTRICAL EQUIPMENT SCHEDULE KEY OTY MANUFACTURER MODEL NOTES TRADE 1 12 HYUNDAI HIS-S265RG (265W) PV MODULE SOLAR 2 12 ENPHASE M215-60-2LL-S22-IG PV INVERTER SOLAR 3 1 RSTC/SOLADECK 0786-3R5 PV ROOF JUNCTION BOX,NEMA 3R SOLAR 4 1 CUTLER-HAMMER DG221URB PV AC DISCONNECT.NEMA 3R,240V,30A SOLAR 5 1 ENPHASE ENVOY PV DATA MONITOR, 120V SOLAR 6 1 TBD TBD 120V DEDICATED RECEPTACLE FOR ENVOY PV DATA MONITOR SOLAR 7 1 TBD TBD CATS PORT FOR SOLAR PV INTERNET CONNECTION TO HOME NETWORK BOX SOLAR 8 NOTE CUTLER-HAMMER TBD PV BRANCH CIRCUIT BREAKERS: I X ISA-IP(ENVOY) SOLAR 9 NOTE CUTLER-HAMMER TBD PV BREAKER, I X 20A-2P,LOCATE AT OPPOSITE END OF BUS FROM MAIN BREAKER SOLAR 10 I TBD TBD SERVICE PANEL,MIN. 125A BUS BLDR. ELEC. 11 I TBD TBD UTILITY METER,IPH, 120/240V.200A BLDR. ELEC. 12 11 1 TBD I TBD I GROUNDING ELECTRODE UFER I BLDR..ELEC. CID CTOR SIZING CALCULATIONS INTERCONNECTION CALCULATIONS ION OF USE(COU): I (AMPACITY'TEMP. DERATE-FILL DERATE)VB. REO'D(IMAX) ITEM UNIT PANEL 2)TER INALS(TERM): I AMPACITY AT TERMINALS. a. REQ'D, (IMAX• 1.25) PANEL MFR. CUTLER-HAMMER KEr ZE CU/AL INSULATION CALC. AMPACITY W/0 TEMP. FILL RESULT REO'D OCD BUS RATING AMPS 200 TYPE DERATES DERATE DERATE (A) (A) USED(A) MAIN DISCONNECT AMPS 200 A' #12 CU THWN-2 COU 30 0.76 1.0 22.80 10.80 ALLOWED PV PER NEC AMPS 40 TERM 25 25 13.50 20 PV OCPD DEVICE USED AMPS 20 E, 10 CU NM-B COU 40 0.91 1.0 36.40 10.80 'W' TERM 35 35 13.50 20 C #10 CU NM-8 COU 40 0.91 1.0 36.40 10.80 AlL TERM 35 35 13.50 20 UCTOR SCHEDULE ONDUCTORS CU/AL TYPE 1 LOCATION TRADE A I-#12 ENGAGE CABLE, I-#6G,FREE AIR CU TC-ER ARRAY SOLAR B 3-#10. 1-#10 EGC I CU NM-B (ROMEX) INTERIOR SOLAR 3-#10, 1-#10 EGC I CU NM-B(ROMEX) INTERIOR SOLAR Q CAT5E,ETHERNET CABLE I CU CAT5E I INTERIOR SOLAR 5 © II oo_�7 • o a i M — SEE NOTE 15 10 fAV� Q 0 SAIIP O O LO 3 N I A B I L =!2 1 ROOF EXTERIOR-GARAGE 1 ELECTRICAL DIAGRAM 3.18 KW LOT#99 ORIGINAL BY: DESIREE WILLIAMS I DATE:16.3.15 LENNAR: CAMELLIA AT REVIEWED BY:ARTHUR HICKS DATE:16.3.15 CORONA,CA 980 I9 8791VE,#302 REV.# BY DATE DESCRIPTION THE LAKES lanamaste SOLnR DWG TITLE: PAGE#: SCALE: SITE LOCATION: 4571 Broadway Street INDIVIDUAL 29684 FALMER CT Boulder,CO 80304 PLOT PLAN 2 NTS MENIFEE,CA 303.447.0300 ELECTRICAL STRUCTURAL NOTES: SOLAR CONTRACTOR- 1)ALL PV ROOF ATTACHMENTS WILL BE SPACED ALONG MODULE RACKING RAILS AT NOT GREATER THAN 48'O.C. 2)ALL PV ROOF ATTACHMENTS.WILL BE STAGGERED BY ROW AMONGST THE ROOF FRAMING MEMBERS,TO MAXIMUM EXTENT POSSIBLE. 3)ROOF PENETRATIONS ASSOCIATED WITH SOLAR RACKING WILL BE SEALED WITH AN APPROVED SEALANT. 4)SOLADECK WIRE TRANSITION BOX WILL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS. IT WILL BE FLASHED AND SEALED. 5)PV ARRAY WILL BE A MINIMUM OF 3'ABOVE THE COMPOSITE SHINGLE ROOF SURFACE. 6)THE UNIRAC SOLARMOUNT RACKING SYSTEM AND SOLAR PV ARRAY WILL BE INSTALLED ACCORDING TO THE UNIRAC SOLARMOUNT CODE-COMPLIANT INSTALLATION MANUAL,VERSION 227.3, PUB 140113-ICC,JANUARY 2014. 7)UNIRAC TOP CLAMPS REQUIRE A ONE INCH(1')SPACE BETWEEN PV MODULES.SOLARMOUNT RAILS MUST EXTEND A MINIMUM OF TWO INCHES(21 BEYOND THE EDGE OF THE PV ARRAY/SUB-ARRAY. B)UNIRAC SOLARMOUNT REQUIRES THAT A THERMAL EXPANSION GAP BE INSTALLED FOR ANY RAIL LENGTH OF GREATER THAN 40'. ROOFING CONTRACTOR- )ARTMENT 1)DISTANCE BETWEEN ARRAY EDGE AND TRANSITION FLASHING (COMPOSITION TO TILE)WILL BE A MINIMUM OF 3'. 2)26 GAUGE INTERLOCKING FLASHING SIDEWALL'TO BE INSTALLED ALONG THE LENGTH OF THE PV ARRAY AT ROOFING MATERIAL TRANSITION. IT SHALL BE APROVED PRIOR TO PV SYSTEM INSTALLATION. 3)PEEL-N-STICK BASE TO BE INSTALLED ONE FOOT(I')OR MORE BEYOND THE EDGE OF THE COMPOSITION SHINGLE,DOWN TO THE ROOF EAVE.PEEL-N-STICK BASE TO BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS. 4)AREAS UNDER EACH PV ARRAY SHALL BE ROOFED WITH COMPOSITION SHINGLE. COMPOSITION SHINGLE SHALL RUN FROM ABOVE THE PV ARRAY TO THE ROO � o AVE'' 5)TILE INSTALLED BELOW THE ARRAY TO BE INSTALLED ABOVE THE COMPOSITION ROOF PER ROOFER SPECIFICATIONS. .. ` 6)BIRDSTOP WILL BE INSTALLED AT THE UPPERMOST TRANSITION FROM TILE TO COMPOSITION SHINGLE. BIRDSTOP TO BE SPECIFIED BY ROOI`g 4_T0 INSTALLATION. DATE D be a permit for,or an e federal,state or city d plans must be kept on the ELECTRICAL NOTES: GENERAL- D ALL PV EQUIPMENT WILL BE TESTED AND LISTED FOR ITS USE BY A NATIONALLY RECOGNIZED TESTING LABORATORY(NRTL). 2)THE GROUNDING OF THE PHOTOVOLTAIC SYSTEM SHALL COMPLY WITH THE APPLICABLE VERSION OF THE NEC/CEC. 3)ALL GROUNDING ELECTRODE CONDUCTORS WILL BE INSTALLED IN A CONTINUOUS LENGTH EXCEPT WHERE SPLICED BY AN IRREVERSIBLE CONNECTOR OR EXOTHERMIC WELD. 4)NON-CURRENT CARRYING METAL PARTS SHALL BE CHECKED FOR PROPER GROUNDING,NOTING THAT TERMINAL LUGS BOLTED ON AN ENCLOSURE'S FINISHED SURFACE MAY BE ELECTRICALLY INSULATED BECAUSE OF PAINT/FINISH. PAINT/FINISH AT POINT OF CONTACT SHALL BE PROPERLY REMOVED. 5)ROOF PENETRATIONS WILL BE COMPLETED AND SEALED PER APPLICABLE CODE. 6)ALL CONDUCTORS WILL HAVE A 90°C RATING TO ENSURE CODE COMPLIANCE. SOLAR CONTRACTOR- 7)MODULE CERTIFICATIONS WILL INCLUDE UL1703, IEC61646, IEC61730. B)CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS. 9)RACEWAY POINT OF PENETRATION FROM EXTERIOR TO INTERIOR WILL BE SEALED TO PREVENT INGRESS OF WATER AND INSECTS. 10)DC WIRING IS LIMITED TO PV ARRAY FOOTPRINT W/ENPHASE MICRO-INVERTER SYSTEM. ID MODULE AND ENPHASE WIRING SHALL BE LOCATED AND SECURED UNDER THE ARRAY USING SUITABLE WIRING CLIPS. WIRING SHALL NOT MAKE CONTACT WITH THE ROOF SURFACE AND SHALL BE MANAGED IN A WORKMAN-LIKE MANNER. 12)EQUIPMENT GROUNDING CONDUCTORS WILL BE SIZED IN ACCORDANCE WITH NEC TABLE 250.122. 13)CONDUCTOR TERMINATIONS WILL BE TORQUED PER DEVICE LISTING,OR MANUFACTURER'S RECOMMENDATIONS. 14)A PV AGGREGATION PANEL(SUB PANEL)WILL NOT BE INCLUDED FOR SYSTEMS WITH ONE BRANCH CIRCUIT. 15)A DEDICATED 120V BRANCH CIRCUIT IS REQUIRED IN MASTER.CLOSET(OR EQUIVALENT)FOR ENPHASE ENVOY MONITOR. SIGNAGE- 16)PV SYSTEMS SHALL BE CLEARLY MARKED IN ACCORDANCE WITH NEC ARTICLE 690 AND OTHER APPLICABLE STATE AND LOCAL CODES. 17)ALL SAFETY MARKING /PLACARDS SHALL BE PERMANENTLY ATTACHED BY ADHESIVE OR OTHER MECHANICAL MEANS. 18)MARKING/PLACARDS WILL BE METAL OR PLASTIC WITH ENGRAVED OR MACHINE PRINTED LETTERING. BACKGROUND WILL BE RED WITH WHITE CAPITAL LETTERING OF MINIMUM HEIGHT t. 19)ALL WIRING/RACEWAYS/JUNCTION BOXES WILL BE MARKED'PHOTOVOLTAIC POWER SOURCE;OR EQUIVALENT;WIRING/RACEWAYS SHALL BE MARKED EVERY 10'. BUILDER ELECTRICAL AND SOLAR CONTRACTORS- 20) INSTALLATION SHALL BE COMPLETED IN A NEAT AND WORKMAN-LIKE MANNER. 21)SPACE REQUIREMENTS FOR ALL ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110.26. LENNAR: ORIGINAL BY: DESIREE WILLIAMS DATE:16.3.15 CAMELLIA AT 9BO MONTECITO DRIVE,#302 REVIEWED BY:ARTHUR HICKS DATE:16.3.15 THE LAKES CORONA,CA 92879 REV.$ BY DATE DESCRIPTION Q1a namasbe seise DWG TITLE: PAGE#: SCALE: SITE LOCATION: 4571 Broadway Street INDIVIDUAL 29684 FALMER CT Boulder,CO 80304 PLOT PLAN 3 NTS NOTES MENIFEE,CA 303.447.0300 CAUTION: POWER TO THIS BUILDING IS SUPPLIED BY THE UTILITY AND A SOLAR PV SYSTEM. DISCONNECTS ARE LOCATED AS SHOWN. BOLADECN WIRE TRANSITION BOX (UNDER ARRAY) Lm IT PV AC DISCONNECT EXTERIOR-GARAGE UTILITY METER 6 RAIN SERVICE PANEL (VERIFIED BY BUILDER) SERVICE BY QUALIFIED PERSONNEL ONLY CONTACT: SUNSTREET ENERGY GROUP 1-877-SLR-POWR PV POWER SOURCE - AC SPECS AC OPERATING VOLTAGE: 240 V AC OPERATING CURRENT: 10.8 A NOTE: SEE MASTER SET FOR ADDITIONAL PLACARD INFORMATION : ORIGINAL BY: DESIREE WILLIAMS DATE:16.3.15 CAMELLIA AT LENNAR 980 MONTECITO DRIVE, #302 REVIEWED BY:ARTHUR HICKS DATE:16.3.15 THE LAKES CORONA,CA 92879 REV.# BY DATE DESCRIPTION Gl4 namaste SOLAR DWG TITLE: PAGE #: SCALE: SITE LOCATION: 4571 Broadway Street INDIVIDUAL 29684 FALMER CT Boulder,CO 80304 PLOT PLAN 4 NTS MENIFEE,CA PLACARDS 303.447.0300