PMT16-00276 City of Menifee Permit No.: PMT16-00276
29714 HAUN RD. Type: Residential Addition
�CCELA? MENIFEE,CA 92586
MENIFEE Date Issued:
02/11/2016
PERMIT
Site Address: 30920 PERRINE ST, MENIFEE, CA 92586 Parcel Number: 472-020-015
Construction Cost: $4,600.00
Existing Use: 1 &2 Family Residence Proposed Use:
Description of INSTALL ATTACHED PREFAB SUNROOM 231 SQ FT WITH 3 OUTLETS, 1 OUTDOOR LIGHT AND
Work: SWITCH
Owner Contractor
GEORGE ESPINO WINDTEX INC
30920 PERRINE STREET 14601ARMINTA ST
MENIFEE, CA'92586 PANORAMA CITY, CA 91402
Applicant Phone:8183040810
LORENA GARCIA License Number:831210
14601 ARMINTA ST
PANORAMA CITY, CA 91402
Fee Description QQtr Amount ISI
Receptacle,Switch, Outlet&Fixture 5 136.00
Building Permit Issuance 1 27.00
Additional Plan Review Building 74 74.18
GREEN FEE 1 1.00
SMIP RESIDENTIAL 1 1.00
General Plan Maintenance Fee-Electrical 1 7.05
$246.23
The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and
specifications or from preventing builiding operations being carded on thereunder when in violation of the Building Code or of any other
ordinance of City of Menifee.Except as otherwise stated,a permit for construction under which no work is commenced within six
months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be
forfeited.
AA_Bidg_Pernit Template.rpt Page 1 of 1
CITY OF MEN IFEE
LICENSED DECLARATION property who builds or improves thereon,and who contracts for the projects
I hereby affirm under penalty of perjury that I am under provisions of with a licensed contractor(s)pursuant to the Contractors State License Law).
Chapter9(commencing with section 7000)of Division 3 of the Business and ❑I am exempt from licensure under the Contractors State License Law for
Professions Code and
my license is in full force and effect. the following reason:
Ucense Class License No. Q 3 12,1 V By my signature below I acknowledge that,except for my personal residence
Expires 1 c7/ Signature in which I most have resided for at(east one year prior to completion of
improvements covered by this permit I cannot legally sell a structure that I
WORKER'S COMPENSATION DECLARATION have built as an owner-builder if it has not been constructed in Its entirety by
❑I hereby affirm under penalty of perjury one of the following declarations:I licensed contractors.I understand that a copy of the applicable law,Section
have and will maintain a certificate of consent of self-insure for workers 7044 of the Business and Professions Code,is available upon request when
compensation,issued by the Director of Industrial Relations as provided for this application is submitted or at the following website:
by Section 3700 of the Labor Code,for the performance of work for which
this permit is issued. www.leeinfo.ca.eov/calaw.html.
Poll-gyp Date
d1 have and will maintain workers compensation insurance,as required by PROPERTY OWNER OR AUTHORIZED AGENT
section 3700 of the Labor Code,for the performance of the work for which ❑By my signature below I certify to each of the following:I am the property
this permit is issued.My workers compensation insurance carder and policy owner or authorized to act on the property owners behalf.I have read this
number are: application and the information I have provided is correct 1 agree to comply
With all applicable city and county ordinances and state laws relating to
Cartier /� building construction.I authorize representatives of this city or county to
Policy#ZI3 ,L42 Expires 811 r&117/6 ender the above identified property for inspection purposes.
(This section need not to be completed is the permit is for one-hundred Date
dollars($100)or less PROPERTY OWNER OR AUTHORIZED AGENT
❑I certify that in the performance of the work for which this permit is issued,
I shall not employ any persons in any manner so as to become subject to the CITY BUSINESS LICENSE#
workers compensation laws of California,and agree that if I should become HAZARDOUS MATERIAL DECLARATION
subject to the workers compensation provisions of Section 3700 of the Labor
Code,I shall forhwithaomply those provisions. Will the applicant or future building occupant handle hazardous material or a
�f/�� Date 7//d�/J!m— mixture containing a hazardous material equal to or greater that the
Applicant
amounts specified on the Hazardous Materials Information Guide?
WARNING:FAILURE TO SECURE WORKER'S COMPENSATION COVERAGE IS ❑Yes ci No
UNLAWFUL,AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES Will the intended use of the building by the applicant or future building
AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS($10D,000),IN occupant require a perm it for the construction or modification from South
ADDITION TO THE COST OF COMPENSATION,DAMAGES AS PROVIDED FOR Coast Air Quality Management District(SCAQMD)?See permitting checklist
IN SECTION 3706 OF THE LABOR CODE,INTEREST,AND ATTORNEYS FEES forguldelines
CONSTRUCTION LENDING AGENCY ❑Yes ❑No
I hereby affirm that under the penalty of perjury there is a construction Will the proposed building or modified facility be within 1000 feet of the
lending agency for the performance of the work which this permit is Issued outer boundary of a school?
(Section 3097 Civil Code) 0 Yes ❑No
OWNER BUILDER DECLARATIONS I have read the Hazardous Material Information Guide and the SCAQMD
permitting checklist I understand my requirements under the State of
I hereby affirm under penalty of perjury that I am exempt from the
Contractors License Law for the reason(s)indicated below by the California Health Safety Code,Section 2S5o5 and 25534 concerning
checkmark(s)I have placed next to the applicable item(s)(Section 7031.5 hazardous material reporting.
OVes ❑No
Business and Professions Code).Any city or county that requires a permit to
Date
construct,alter,improve,demolish or repair any structure,priorto its PROPERLY OWNER OR AUTHORIZED AGENT
Issuance,also requires the applicant for the permit to file a signed statement
that he or she is licensed pursuant to the provisions of the Contractors State EPA RENOVATION,REPAIR AND PAINTING IRRPI
License Law(Chapter 9(commencing with Section 7000)of Division 3 of the The EPA Renovation,Repair and Painting(RRP)Rule requires contractors
Business and Professions Code)or that he or she is exempt from licensure receiving compensation for most work that disturbs paint in a pre-1978
and the basis for the alleged exemption.Any violation of Section 7031.5 by residence or childcare facility to be RRP-certified firms and comply with
an Applicant for a permit subjects the applicant to a civil penalty of not more required practices.This includes rental property owners and property
than($500). managers who do the paint-disturbing work themselves or through their
❑1,as owner of the property,or my employee with wages as their sole employees.For more information about EPA's Renovation Program visit:
compensation,will do( )all of or( )portion of the work,and the structure is www.eoa.aov/lead or contact the National Lead Information Center at
not intended or offered for sale.(Section 7044,Business and Professions 1-800-424-LEAD(5323).
Code;The Contractors State License Law does not apply to an owner of a ❑An EPA Lead-Safe Certified Renovator will be responsible for this project
Property who,through employees'or personal effort,builds or Improves the
property provided that the improvements are not intended or offered for Certified Firm Name:
sale.If,however,the building or improvement is sold within one year of Firm Certification No.:
completion,the owner-Builder will have the burden of proving that it was
not built or improved for the purpose of sale. ❑No EPA Lead-Safe Certified Firm is required for this project because:
❑1,as owner of the property am exclusively contracting with licensed
contractors to construct the project(Section 7044,Business and Professions
Code:The Contractors State License Law does not apply to an owner of a If your project does not comply with EPA RRP rule please fill out the RRP
Acknowledgement.
BUILDING & SAFETY PERMIT/PLAN CHECKAPPLICATION
l
-�-�" Ienifee
DATE 2'3ll(o PERMIT/PLAN CHECK NUMBER
TYPE: ❑COMMERCIAL gIRESIDENTIAL []MULTI-FAMILY ❑MOBILEHOME POOL/SPA ❑SIGN
SUBTYPE: ❑ADDITION ❑ALTERATION ❑DEMOLITION [DILECTRICAL ❑MECHANICAL
❑NEW ❑PLUMBING ❑RE-ROOF-NUMBER OF SQUARES
DESCRIPTION OF WORK LLo ;, w OF p
PROJECTADDRESS 3D9Zp InLL\Z Dly�f�ng-? Bfety Dept.
y
ASSESSOR'S PARCEL NUMBER 7, p 7 00,y LOT /5 TRACT /-FEB/0 3 2016
PROPERTY OWNER'S NAME C /I n
RVLvived
ADDRESS 30 LO , ?'. WI/1C,L,¢ 9 s--1
PHONE /� �-JZI.� � EMAIL
APPLICANT NAME Lbrell F (7 GI rGl CA
ADDRESS Q 2 o c S ( 0'(7 S
PHONE (Gj(9Z� n�(p -Z✓.�j�olo EMAIL
CONTRACTOR'S NAME - / iv OWNERBUILDER7 ❑YESEL]<
BUSINESS NAME //JJ
ADDRESS LIDO MI'T� ,S'-r, rq o 91,102-
PHONE R) '30L4 JCl EMAIL
CONTRACTOR'S STATE LIC NUMBER <D7 1 \ (') LICENSE CLASSIFICATION
VALUATION$ O o SO FT L SO FT
APPLICANT'S SIGNATURE DATE
DEPARTMENT DISTRIBUTION CITY OF MENIFEE BUSINESS LICENSE NUMBER
BUILDING PLANNING ENGINEERING FIRE I GREEN SMIP
INVOICE PAID AMOUNT
r
OCASH OCHECK# OCREDITCARD VISA/MC
CHECK FEES PAIDAMOUNT „CASH OCHECKB OCREDITCARD VISA/MC
ILDER VERIFIED OYES O NO DL NUMBER NOTARIZED LETTER O YES O NO
City of Menifee Building&Safety Deportment 29714 Haun Rd. Menifee, CA 92586 951-672-6777
www.cityofmenifee.us Inspection Request Line 951-246-6213
11
UE$ 181
EVALUATION 1 e Igg17�,ir
M Originally Issued: 0112 012 01 2 Revised: 07/1 012 01 5 Valid Through: 0113 1/2 01 6
EVALUATION SUBJECT: and post extrusions. The LRP panels, made of structural
OMEGA 4 WALL AND LPR OR GLASS ROOF insulated panels with polystyrene foam plastic cores and
SYSTEM aluminum skins,are outside the scope of recognition of this
City of Menifee
Building & Safety Dept report. LRP panels used with the structural components
.
REPORT HOLDER: described in this report to form enclosed residential patio
C-Thru Industries FEB 0 3 2016 covers, shall be recognized and listed by an approved and
1477 Davril Circle accredited listing agency.The extrusions shall be designed as
Corona CA 92880 described in Section 4.1 of this report to support the loads
c__thnl.Com described in the attached drawings.
Received
CSI Division: 10-SPECIALTIES 3.1.3 Glass Roof System: The support framing system for
CSI Section: 10 73 00-Protective Covers the glass roof panels are designed in accordance with 2012
IBC Section 2403.3 with deflection limited to the lesser of
1.0 SCOPE OF EVALUATION L/175 of the glass edge length or 0.75 inch.The glazing for
the glass roof shall be impact resistant as required by Section
1.1 Compliance to the following codes& regulations: 1609.1.2 of the 2012 IBC,and shall be designed,supported,
a 2012 International Building Code®(IBC) glazed, screened, and identified in accordance with Chapter
e 2012 International Residential Code®(IRC) 24 of the 2012 IBC.
e See California and Florida Supplements following
this report for additional compliance statements 4.0 DESIGN AND INSTALLATION
1.2 Evaluated in accordance with: 4.1 Design: The appropriate design criteria for live load,
e ICC-ES Acceptance Criteria for Patio Covers (AC wind speed and exposure category,seismic design category,
340)approved June 2012,revised August 2013 rain load and ground snow load conditions shall be
determined in accordance with Chapter 16 of the IBC or
13 Properties assessed: Section R301 of the IRC, as applicable. The design criteria
• Structural shall be confirmed by consulting the applicable local codes
and ordnances, and the building code official. The design
2.0 PRODUCT USE criteria determined above shall be used with the design steps
and tables in the attached drawings to determine the
The combination of the Omega 4 Wall System and the LRP appropriate configurations for the Omega 4 Wall and Roof
or glass Roof System,together with wall and LRP or glass System based on the design loads occurring at the building
roof panels,form a system used as an attached patio enclosure site. The project location, use (patio cover, carport,
for residential applications.These enclosures are intended to commercial structure), corresponding code, and applicable
be non-habitable structures associated with a dwelling unit design criteria, including risk category (IBC only) wind
conforming to Appendix I of the International Building Code speed,wind exposure category, roof live load, ground snow
and Appendix H of the International Residential Code and load, seismic design category, and frost line depth shall be
not as carports,garages,storage rooms or habitable rooms. placed on or be attached to the plans accompanying this
report and be observed in the selection of the components.
3.0 PRODUCT DESCRIPTION
4.1.1 Roof System:The support system for the LRP or glass
3.1 Product information roof panels shall be designed in accordance with the design
steps and tables in the attached drawings. The LRP panels
3.1.1 Omega 4 Wall System: The Omega 4 Wall System shall be manufactured and installed in accordance with the
described in drawings 1 thru 16, consists of bearing and listing or evaluation report that governs their use.The glass
nonbearing wall panels of aluminum skins with expanded panels shall be as described in Section 3.1.3 of this report.
polystyrene cores, and aluminum mullions and posts with an
alloy and temper of 6063-T6.The recognition pertains to the 4.1.2 Omega 4 Wall System: The Omega 4 Wall System
ability of the mullions, posts, and fasteners to support the shall be used in accordance with the procedures and tables
patio structure, including the wall panels, in response to the beginning on Drawing 12 to determine the appropriate wall
design loads.The wall panels and glass panels are outside the components for the design loads.
scope of recognition of this report.
4.1.3 Assembly: Assembly of the components determined
3.1.2 LRP Roof System:The LRP Roof System described in for use in Sections 4.1.1 and 4.1.2 shall be in accordance with
drawings 4 thru 7 consists of aluminum ledger,beam,rail, the details provided in this report and in accordance with the
local governing building code. _
The product oescdW in this Umform Evaluation Service(UES)Report has been evaluated as an alternative material,design or method of constmctmn In order to solely end comply will(ES
the intent of the provBbn or Me code,as noted In this report,and for at least equivalence to that presalbedM the code In quality,strength,effectiveness,fire resistance,durabilly and solely,
as applicable.In accordance wife IBC Section 104.11.
Copyright 02015 by lntemationa/Association of Plumbing and Mochanioal Officials.All tights reserved.PMted in the United States No part of this publication may he reproduced stated In
an eleceonk nebiaval system,or transmitted in any form or by any means,electronic,mechanical,photocopying,mcamiing or ofherMse,without the prior written permissbn of the publisher.
Ph:1-977-41ESRPr•Fm.909.4 72.4171-web:www.unllcrm�s.org•4755 East Philadelphia Street,Onfarin,Cafdomia 91761-2816—USA
uEsE"LUATION REPORT . - c 181
Originally Issued: 01/20/2012 Revised: 07/10/2015 Valid Through: 01/3112016
4.2 Installation: General installation shall be in accordance 6.0 SUBSTANTIATING DATA
with the codes in Section 1 of this report,this report,the
manufacturer's published installation instructions, and Data and analysis in accordance with the ICC-ES acceptance
corresponding drawings dated 06/14/2014, and revised criteria for patio covers (AC340) approved June 2012,
05/04/2015. Installation of the LRP Roof panels shall be in revised August 2013. Test results are from laboratories in
accordance with the evaluation report governing the LRP compliance with ISO/IEC 17025.
panels. Approved sealant or caulking shall be used at any
penetrations made in the existing weather resistant exterior 7.0IDENTIFICATION
wall envelope and weather protection shall be provided as
required by IBC 1403.2.Enclosure wall configurations used Each installation shall bear an original identifying decal or
forming enclosed attached residential patio covers shall label bearing the company name or trademark, model
conform to the limits noted in Section 1103 of the IBC and number, and the IAPMO Uniform ES Mark of Conformity
Section AH103 of the IRC. and the Evaluation Report Number(ER-181)to identify the
products recognized in this report. The label shall be affixed
5.0 LIMITATIONS on at least one of the following: product, packaging,
installation instructions or descriptive literature.Either Mark
The C-Thru Industries enclosed patio system described in the of Conformity may be used as shown below:
accompanying plans dated 06/14/2014, and revised
05/04/2015 bearing the name C-Thru Industries and VTA
Consulting Engineers, comply with the codes listed in A NTM
Section 1.0 of this report and are subject to the followingP M�conditions:
ES5.1 The materials and components described in this report are ® or
to be limited to non-habitable spaces associated with a IAPMO ER#181
dwelling unit described in Appendix I of the International
Building Code and Appendix H of the International
Residential Code. > -
I-
5.2 Analysis shall be provided to the building official to show Brian Gerber,P.E.,S.E.
component and cladding wind loads at the site are less than Vice President,Technical Operations
the capacity of the glass panels in accordance with IBC Uniform Evaluation Service
Chapter 24.
5.3 Construction of the enclosed patio system shall complywith this this report,the accompanying plans,dated 06/14/2014, Richard Beck,PE,CBO,MCP
and revised 05/04/2015, and the manufacturer's installation Vice President,Uniform Evaluation Service
instructions.Where conflicts occur,the more restrictive shall
govern.
5.4 Windows serving as emergency egress or rescue openings GP Russ Chan y
from the sleeping rooms are not permitted to exit into the CEO,The IAPMO Group
patio enclosure.
5.5 Where an exterior opening serves as an exit from the For additional information about this evaluation report please visit
wwu'.uniform-e,.,r, or email at ink,n uniform-es.om
dwelling unit, the patio enclosure shall have at least a 36-
inch-wide exterior door.
5.6 The scope ofthe report is limited to the sites that have no C-Thru Industries Trademark: Each install shall bear an
special topographical effects like hills,ridge or escarpment. original identifying decal or logo of C-Thru Industries thus:
5.7 The effects of sliding snow described in Section 7.9 of C-Thru Logo
ASCE 7-10 are outside the scope of this report.
5.8 The roof support systems shall have a slope of at least''/4
inch per foot(2.083 percent). EiR
Page 2 of 2
VJES t i ,._ �. 181
Originally Issued: 01/2 012 01 2 Revised: 07/10/2015 Valid Through: 01/3112016
CALIFORNIA SUPPLEMENT
EVALUATION SUBJECT:
OMEGA 4 WALL AND LRP OR GLASS ROOF
SYSTEM
REPORT HOLDER:
C-Thru Industries
1477 Davril Circle
Corona CA 92880
littp7//www.c-thru.com
CSI Division: 10-SPECIALTIES
CSI Section: 10 73 00—Protective Covers
1.0 SCOPE OF EVALUATION
1.1 Compliance to the following codes& regulations:
• 2013 California Building Code(CBC)
• 2013 California Residential Code(CRC)
2.0 FINDINGS
The Omega 4 Wall System and LRP or glass Roof System
described in IAPMO UES Evaluation Report ER-181 comply
with the codes listed in Section 1.1 of this supplement. Use
and installation shall be in accordance with ER-181 and its
corresponding drawings, the manufacturer's published
installation instructions, and Appendix I of the CBC, or
Appendix H of the CRC,as applicable.
The site specific design criteria for live load,wind speed and
exposure category, seismic design category, rain load and
ground snow load conditions shall be determined in
accordance with Chapter 16 of the CBC or Section R301 of
the CRC, as applicable. The appropriate configurations for
the Omega 4 Wall and Roof System shall be determined in
accordance with Sections 4.1,4.1.1,4.1.2, and 4.1.3 of ER-
181 based on the design loads determined in accordance with
the CBC or CRC for the building site.
For additional information about this evaluation report please
visit wwev uniform-es.ore or email at info a-unirorm-es.ora.