Loading...
PMT16-00276 City of Menifee Permit No.: PMT16-00276 29714 HAUN RD. Type: Residential Addition �CCELA? MENIFEE,CA 92586 MENIFEE Date Issued: 02/11/2016 PERMIT Site Address: 30920 PERRINE ST, MENIFEE, CA 92586 Parcel Number: 472-020-015 Construction Cost: $4,600.00 Existing Use: 1 &2 Family Residence Proposed Use: Description of INSTALL ATTACHED PREFAB SUNROOM 231 SQ FT WITH 3 OUTLETS, 1 OUTDOOR LIGHT AND Work: SWITCH Owner Contractor GEORGE ESPINO WINDTEX INC 30920 PERRINE STREET 14601ARMINTA ST MENIFEE, CA'92586 PANORAMA CITY, CA 91402 Applicant Phone:8183040810 LORENA GARCIA License Number:831210 14601 ARMINTA ST PANORAMA CITY, CA 91402 Fee Description QQtr Amount ISI Receptacle,Switch, Outlet&Fixture 5 136.00 Building Permit Issuance 1 27.00 Additional Plan Review Building 74 74.18 GREEN FEE 1 1.00 SMIP RESIDENTIAL 1 1.00 General Plan Maintenance Fee-Electrical 1 7.05 $246.23 The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and specifications or from preventing builiding operations being carded on thereunder when in violation of the Building Code or of any other ordinance of City of Menifee.Except as otherwise stated,a permit for construction under which no work is commenced within six months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be forfeited. AA_Bidg_Pernit Template.rpt Page 1 of 1 CITY OF MEN IFEE LICENSED DECLARATION property who builds or improves thereon,and who contracts for the projects I hereby affirm under penalty of perjury that I am under provisions of with a licensed contractor(s)pursuant to the Contractors State License Law). Chapter9(commencing with section 7000)of Division 3 of the Business and ❑I am exempt from licensure under the Contractors State License Law for Professions Code and my license is in full force and effect. the following reason: Ucense Class License No. Q 3 12,1 V By my signature below I acknowledge that,except for my personal residence Expires 1 c7/ Signature in which I most have resided for at(east one year prior to completion of improvements covered by this permit I cannot legally sell a structure that I WORKER'S COMPENSATION DECLARATION have built as an owner-builder if it has not been constructed in Its entirety by ❑I hereby affirm under penalty of perjury one of the following declarations:I licensed contractors.I understand that a copy of the applicable law,Section have and will maintain a certificate of consent of self-insure for workers 7044 of the Business and Professions Code,is available upon request when compensation,issued by the Director of Industrial Relations as provided for this application is submitted or at the following website: by Section 3700 of the Labor Code,for the performance of work for which this permit is issued. www.leeinfo.ca.eov/calaw.html. Poll-gyp Date d1 have and will maintain workers compensation insurance,as required by PROPERTY OWNER OR AUTHORIZED AGENT section 3700 of the Labor Code,for the performance of the work for which ❑By my signature below I certify to each of the following:I am the property this permit is issued.My workers compensation insurance carder and policy owner or authorized to act on the property owners behalf.I have read this number are: application and the information I have provided is correct 1 agree to comply With all applicable city and county ordinances and state laws relating to Cartier /� building construction.I authorize representatives of this city or county to Policy#ZI3 ,L42 Expires 811 r&117/6 ender the above identified property for inspection purposes. (This section need not to be completed is the permit is for one-hundred Date dollars($100)or less PROPERTY OWNER OR AUTHORIZED AGENT ❑I certify that in the performance of the work for which this permit is issued, I shall not employ any persons in any manner so as to become subject to the CITY BUSINESS LICENSE# workers compensation laws of California,and agree that if I should become HAZARDOUS MATERIAL DECLARATION subject to the workers compensation provisions of Section 3700 of the Labor Code,I shall forhwithaomply those provisions. Will the applicant or future building occupant handle hazardous material or a �f/�� Date 7//d�/J!m— mixture containing a hazardous material equal to or greater that the Applicant amounts specified on the Hazardous Materials Information Guide? WARNING:FAILURE TO SECURE WORKER'S COMPENSATION COVERAGE IS ❑Yes ci No UNLAWFUL,AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES Will the intended use of the building by the applicant or future building AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS($10D,000),IN occupant require a perm it for the construction or modification from South ADDITION TO THE COST OF COMPENSATION,DAMAGES AS PROVIDED FOR Coast Air Quality Management District(SCAQMD)?See permitting checklist IN SECTION 3706 OF THE LABOR CODE,INTEREST,AND ATTORNEYS FEES forguldelines CONSTRUCTION LENDING AGENCY ❑Yes ❑No I hereby affirm that under the penalty of perjury there is a construction Will the proposed building or modified facility be within 1000 feet of the lending agency for the performance of the work which this permit is Issued outer boundary of a school? (Section 3097 Civil Code) 0 Yes ❑No OWNER BUILDER DECLARATIONS I have read the Hazardous Material Information Guide and the SCAQMD permitting checklist I understand my requirements under the State of I hereby affirm under penalty of perjury that I am exempt from the Contractors License Law for the reason(s)indicated below by the California Health Safety Code,Section 2S5o5 and 25534 concerning checkmark(s)I have placed next to the applicable item(s)(Section 7031.5 hazardous material reporting. OVes ❑No Business and Professions Code).Any city or county that requires a permit to Date construct,alter,improve,demolish or repair any structure,priorto its PROPERLY OWNER OR AUTHORIZED AGENT Issuance,also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractors State EPA RENOVATION,REPAIR AND PAINTING IRRPI License Law(Chapter 9(commencing with Section 7000)of Division 3 of the The EPA Renovation,Repair and Painting(RRP)Rule requires contractors Business and Professions Code)or that he or she is exempt from licensure receiving compensation for most work that disturbs paint in a pre-1978 and the basis for the alleged exemption.Any violation of Section 7031.5 by residence or childcare facility to be RRP-certified firms and comply with an Applicant for a permit subjects the applicant to a civil penalty of not more required practices.This includes rental property owners and property than($500). managers who do the paint-disturbing work themselves or through their ❑1,as owner of the property,or my employee with wages as their sole employees.For more information about EPA's Renovation Program visit: compensation,will do( )all of or( )portion of the work,and the structure is www.eoa.aov/lead or contact the National Lead Information Center at not intended or offered for sale.(Section 7044,Business and Professions 1-800-424-LEAD(5323). Code;The Contractors State License Law does not apply to an owner of a ❑An EPA Lead-Safe Certified Renovator will be responsible for this project Property who,through employees'or personal effort,builds or Improves the property provided that the improvements are not intended or offered for Certified Firm Name: sale.If,however,the building or improvement is sold within one year of Firm Certification No.: completion,the owner-Builder will have the burden of proving that it was not built or improved for the purpose of sale. ❑No EPA Lead-Safe Certified Firm is required for this project because: ❑1,as owner of the property am exclusively contracting with licensed contractors to construct the project(Section 7044,Business and Professions Code:The Contractors State License Law does not apply to an owner of a If your project does not comply with EPA RRP rule please fill out the RRP Acknowledgement. BUILDING & SAFETY PERMIT/PLAN CHECKAPPLICATION l -�-�" Ienifee DATE 2'3ll(o PERMIT/PLAN CHECK NUMBER TYPE: ❑COMMERCIAL gIRESIDENTIAL []MULTI-FAMILY ❑MOBILEHOME POOL/SPA ❑SIGN SUBTYPE: ❑ADDITION ❑ALTERATION ❑DEMOLITION [DILECTRICAL ❑MECHANICAL ❑NEW ❑PLUMBING ❑RE-ROOF-NUMBER OF SQUARES DESCRIPTION OF WORK LLo ;, w OF p PROJECTADDRESS 3D9Zp InLL\Z Dly�f�ng-? Bfety Dept. y ASSESSOR'S PARCEL NUMBER 7, p 7 00,y LOT /5 TRACT /-FEB/0 3 2016 PROPERTY OWNER'S NAME C /I n RVLvived ADDRESS 30 LO , ?'. WI/1C,L,¢ 9 s--1 PHONE /� �-JZI.� � EMAIL APPLICANT NAME Lbrell F (7 GI rGl CA ADDRESS Q 2 o c S ( 0'(7 S PHONE (Gj(9Z� n�(p -Z✓.�j�olo EMAIL CONTRACTOR'S NAME - / iv OWNERBUILDER7 ❑YESEL]< BUSINESS NAME //JJ ADDRESS LIDO MI'T� ,S'-r, rq o 91,102- PHONE R) '30L4 JCl EMAIL CONTRACTOR'S STATE LIC NUMBER <D7 1 \ (') LICENSE CLASSIFICATION VALUATION$ O o SO FT L SO FT APPLICANT'S SIGNATURE DATE DEPARTMENT DISTRIBUTION CITY OF MENIFEE BUSINESS LICENSE NUMBER BUILDING PLANNING ENGINEERING FIRE I GREEN SMIP INVOICE PAID AMOUNT r OCASH OCHECK# OCREDITCARD VISA/MC CHECK FEES PAIDAMOUNT „CASH OCHECKB OCREDITCARD VISA/MC ILDER VERIFIED OYES O NO DL NUMBER NOTARIZED LETTER O YES O NO City of Menifee Building&Safety Deportment 29714 Haun Rd. Menifee, CA 92586 951-672-6777 www.cityofmenifee.us Inspection Request Line 951-246-6213 11 UE$ 181 EVALUATION 1 e Igg17�,ir M Originally Issued: 0112 012 01 2 Revised: 07/1 012 01 5 Valid Through: 0113 1/2 01 6 EVALUATION SUBJECT: and post extrusions. The LRP panels, made of structural OMEGA 4 WALL AND LPR OR GLASS ROOF insulated panels with polystyrene foam plastic cores and SYSTEM aluminum skins,are outside the scope of recognition of this City of Menifee Building & Safety Dept report. LRP panels used with the structural components . REPORT HOLDER: described in this report to form enclosed residential patio C-Thru Industries FEB 0 3 2016 covers, shall be recognized and listed by an approved and 1477 Davril Circle accredited listing agency.The extrusions shall be designed as Corona CA 92880 described in Section 4.1 of this report to support the loads c__thnl.Com described in the attached drawings. Received CSI Division: 10-SPECIALTIES 3.1.3 Glass Roof System: The support framing system for CSI Section: 10 73 00-Protective Covers the glass roof panels are designed in accordance with 2012 IBC Section 2403.3 with deflection limited to the lesser of 1.0 SCOPE OF EVALUATION L/175 of the glass edge length or 0.75 inch.The glazing for the glass roof shall be impact resistant as required by Section 1.1 Compliance to the following codes& regulations: 1609.1.2 of the 2012 IBC,and shall be designed,supported, a 2012 International Building Code®(IBC) glazed, screened, and identified in accordance with Chapter e 2012 International Residential Code®(IRC) 24 of the 2012 IBC. e See California and Florida Supplements following this report for additional compliance statements 4.0 DESIGN AND INSTALLATION 1.2 Evaluated in accordance with: 4.1 Design: The appropriate design criteria for live load, e ICC-ES Acceptance Criteria for Patio Covers (AC wind speed and exposure category,seismic design category, 340)approved June 2012,revised August 2013 rain load and ground snow load conditions shall be determined in accordance with Chapter 16 of the IBC or 13 Properties assessed: Section R301 of the IRC, as applicable. The design criteria • Structural shall be confirmed by consulting the applicable local codes and ordnances, and the building code official. The design 2.0 PRODUCT USE criteria determined above shall be used with the design steps and tables in the attached drawings to determine the The combination of the Omega 4 Wall System and the LRP appropriate configurations for the Omega 4 Wall and Roof or glass Roof System,together with wall and LRP or glass System based on the design loads occurring at the building roof panels,form a system used as an attached patio enclosure site. The project location, use (patio cover, carport, for residential applications.These enclosures are intended to commercial structure), corresponding code, and applicable be non-habitable structures associated with a dwelling unit design criteria, including risk category (IBC only) wind conforming to Appendix I of the International Building Code speed,wind exposure category, roof live load, ground snow and Appendix H of the International Residential Code and load, seismic design category, and frost line depth shall be not as carports,garages,storage rooms or habitable rooms. placed on or be attached to the plans accompanying this report and be observed in the selection of the components. 3.0 PRODUCT DESCRIPTION 4.1.1 Roof System:The support system for the LRP or glass 3.1 Product information roof panels shall be designed in accordance with the design steps and tables in the attached drawings. The LRP panels 3.1.1 Omega 4 Wall System: The Omega 4 Wall System shall be manufactured and installed in accordance with the described in drawings 1 thru 16, consists of bearing and listing or evaluation report that governs their use.The glass nonbearing wall panels of aluminum skins with expanded panels shall be as described in Section 3.1.3 of this report. polystyrene cores, and aluminum mullions and posts with an alloy and temper of 6063-T6.The recognition pertains to the 4.1.2 Omega 4 Wall System: The Omega 4 Wall System ability of the mullions, posts, and fasteners to support the shall be used in accordance with the procedures and tables patio structure, including the wall panels, in response to the beginning on Drawing 12 to determine the appropriate wall design loads.The wall panels and glass panels are outside the components for the design loads. scope of recognition of this report. 4.1.3 Assembly: Assembly of the components determined 3.1.2 LRP Roof System:The LRP Roof System described in for use in Sections 4.1.1 and 4.1.2 shall be in accordance with drawings 4 thru 7 consists of aluminum ledger,beam,rail, the details provided in this report and in accordance with the local governing building code. _ The product oescdW in this Umform Evaluation Service(UES)Report has been evaluated as an alternative material,design or method of constmctmn In order to solely end comply will(ES the intent of the provBbn or Me code,as noted In this report,and for at least equivalence to that presalbedM the code In quality,strength,effectiveness,fire resistance,durabilly and solely, as applicable.In accordance wife IBC Section 104.11. Copyright 02015 by lntemationa/Association of Plumbing and Mochanioal Officials.All tights reserved.PMted in the United States No part of this publication may he reproduced stated In an eleceonk nebiaval system,or transmitted in any form or by any means,electronic,mechanical,photocopying,mcamiing or ofherMse,without the prior written permissbn of the publisher. Ph:1-977-41ESRPr•Fm.909.4 72.4171-web:www.unllcrm�s.org•4755 East Philadelphia Street,Onfarin,Cafdomia 91761-2816—USA uEsE"LUATION REPORT . - c 181 Originally Issued: 01/20/2012 Revised: 07/10/2015 Valid Through: 01/3112016 4.2 Installation: General installation shall be in accordance 6.0 SUBSTANTIATING DATA with the codes in Section 1 of this report,this report,the manufacturer's published installation instructions, and Data and analysis in accordance with the ICC-ES acceptance corresponding drawings dated 06/14/2014, and revised criteria for patio covers (AC340) approved June 2012, 05/04/2015. Installation of the LRP Roof panels shall be in revised August 2013. Test results are from laboratories in accordance with the evaluation report governing the LRP compliance with ISO/IEC 17025. panels. Approved sealant or caulking shall be used at any penetrations made in the existing weather resistant exterior 7.0IDENTIFICATION wall envelope and weather protection shall be provided as required by IBC 1403.2.Enclosure wall configurations used Each installation shall bear an original identifying decal or forming enclosed attached residential patio covers shall label bearing the company name or trademark, model conform to the limits noted in Section 1103 of the IBC and number, and the IAPMO Uniform ES Mark of Conformity Section AH103 of the IRC. and the Evaluation Report Number(ER-181)to identify the products recognized in this report. The label shall be affixed 5.0 LIMITATIONS on at least one of the following: product, packaging, installation instructions or descriptive literature.Either Mark The C-Thru Industries enclosed patio system described in the of Conformity may be used as shown below: accompanying plans dated 06/14/2014, and revised 05/04/2015 bearing the name C-Thru Industries and VTA Consulting Engineers, comply with the codes listed in A NTM Section 1.0 of this report and are subject to the followingP M�conditions: ES5.1 The materials and components described in this report are ® or to be limited to non-habitable spaces associated with a IAPMO ER#181 dwelling unit described in Appendix I of the International Building Code and Appendix H of the International Residential Code. > - I- 5.2 Analysis shall be provided to the building official to show Brian Gerber,P.E.,S.E. component and cladding wind loads at the site are less than Vice President,Technical Operations the capacity of the glass panels in accordance with IBC Uniform Evaluation Service Chapter 24. 5.3 Construction of the enclosed patio system shall complywith this this report,the accompanying plans,dated 06/14/2014, Richard Beck,PE,CBO,MCP and revised 05/04/2015, and the manufacturer's installation Vice President,Uniform Evaluation Service instructions.Where conflicts occur,the more restrictive shall govern. 5.4 Windows serving as emergency egress or rescue openings GP Russ Chan y from the sleeping rooms are not permitted to exit into the CEO,The IAPMO Group patio enclosure. 5.5 Where an exterior opening serves as an exit from the For additional information about this evaluation report please visit wwu'.uniform-e,.,r, or email at ink,n uniform-es.om dwelling unit, the patio enclosure shall have at least a 36- inch-wide exterior door. 5.6 The scope ofthe report is limited to the sites that have no C-Thru Industries Trademark: Each install shall bear an special topographical effects like hills,ridge or escarpment. original identifying decal or logo of C-Thru Industries thus: 5.7 The effects of sliding snow described in Section 7.9 of C-Thru Logo ASCE 7-10 are outside the scope of this report. 5.8 The roof support systems shall have a slope of at least''/4 inch per foot(2.083 percent). EiR Page 2 of 2 VJES t i ,._ �. 181 Originally Issued: 01/2 012 01 2 Revised: 07/10/2015 Valid Through: 01/3112016 CALIFORNIA SUPPLEMENT EVALUATION SUBJECT: OMEGA 4 WALL AND LRP OR GLASS ROOF SYSTEM REPORT HOLDER: C-Thru Industries 1477 Davril Circle Corona CA 92880 littp7//www.c-thru.com CSI Division: 10-SPECIALTIES CSI Section: 10 73 00—Protective Covers 1.0 SCOPE OF EVALUATION 1.1 Compliance to the following codes& regulations: • 2013 California Building Code(CBC) • 2013 California Residential Code(CRC) 2.0 FINDINGS The Omega 4 Wall System and LRP or glass Roof System described in IAPMO UES Evaluation Report ER-181 comply with the codes listed in Section 1.1 of this supplement. Use and installation shall be in accordance with ER-181 and its corresponding drawings, the manufacturer's published installation instructions, and Appendix I of the CBC, or Appendix H of the CRC,as applicable. The site specific design criteria for live load,wind speed and exposure category, seismic design category, rain load and ground snow load conditions shall be determined in accordance with Chapter 16 of the CBC or Section R301 of the CRC, as applicable. The appropriate configurations for the Omega 4 Wall and Roof System shall be determined in accordance with Sections 4.1,4.1.1,4.1.2, and 4.1.3 of ER- 181 based on the design loads determined in accordance with the CBC or CRC for the building site. For additional information about this evaluation report please visit wwev uniform-es.ore or email at info a-unirorm-es.ora. Page 1 of 2