PMT15-03904 City of Menifee Permit No.: PMT15-03904
29714 HAUN RD.
�ACCELA7 MENIFEE, CA 92586 Type: Residential Electrical
MENIFEE Date Issued: 12/23/2015
PERMIT
Site Address: 29701 ELMSWOOD CIR, MENIFEE, CA Parcel Number:
92584 Construction Cost: $7,650.40
Existing Use: Proposed Use:
Description of SOLAR TR 30422-3 CAMELLIA
Work: 11 MODULES 2.92KW
LOT 97
Owner Contractor
LENNAR HOMES OF CA LENNAR HOMES OF CALIFORNIA INC
980 MONTECITO DR#302 25 ENTERPRISE
CORONA, CA 92879 ALISO VIEJO, CA 92656
Applicant Phone: 9493498269
JEREMIAH ACAYTURRI License Number.728102
LENNAR HOMES OF CALIFORNIA INC
25 ENTERPRISE
ALISO VIEJO, CA 92656
Fee Description r3,yt Amount 1E1
Solar, Residential or Small Commercial 1 252.00
Building Permit Issuance 1 27.00
GREEN FEE 1 1.00
SMIP RESIDENTIAL 1 1.00
General Plan Maintenance Fee-Electrical 1 12.60
$293.60
The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and
specifications or from preventing building operations being carried on thereunder when in violation of the Building Code or of any other
ordinance of City of Menifee.Except as otherwise stated,a permit for construction under which no work is commenced within six
months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be
forfeited.
AA_Bldg_Pennit Template.rpt Page 1 of 1
PERMIT/PLANBUILDING & SAFETY APPLICATION
Y•.« 5
Menifee
DATE 12/15/2015 PERMIT/PLAN CHECK NUMBER 15 - U6904
TYPE: ❑COMMERCIAL [a RESIDENTIAL [-]MULTI-FAMILY ❑MOBILEHOME ❑POOL/SPA ❑SIGN
SUBTYPE: ❑✓ ADDITION ❑ALTERATION [-]DEMOLITION ❑ELECTRICAL [-]MECHANICAL
❑NEW [-]PLUMBING ❑RE-ROOF-NUMBER OF SQUARES
DESCRIPTION OF WORK Solar Permit-Plan 2399-2.92 kW/11 PCS
Master Solar Permit No.PMT14-02630
PROJECTADDRESS 29701 Elmswood, Menifee, CA92584
ASSESSOR'S PARCEL NUMBER LOT 97 TRACT 30422-3
PROPERTY OWNER'S NAME Lennar Homes of Califomia, Inc.
ADDRESS 980 Montecito Dr.,Suite 302,Corona, CA 92879
PHONE (951)817-3680 EMAIL leremiah.acayturri@lennar.com
APPLICANT NAME Lennar Homes of California, Inc.
ADDRESS 980 Montecito Dr.,Suite 302,Corona,CA
PHONE (951)817-3680 EMAIL leremiah.acaytuni@lennar.com
CONTRACTOR'S NAME Lennar Homes of California, Inc. OWNER BUILDER? OYES❑NO
BUSINESS NAME Lennar Homes of California, Inc.
ADDRESS 980 Montecito Dr., Suite 302, Corona, CA
PHONE (951)817-3680 EMAIL leremiah.acayturri@lennar.com
CONTRACTOR'S STATE LIC NUMBER 728102 LICENSE CLASSIFICATION A&B
VALUATION $ $7.650.40 SQ FT LL S�—
APPLICANT'S SIGNATURE DATE 12/15/2015
CITY STAFF USE ONLY
DEPARTMENT DISTRIBUTION / CITY OF MENIFEE BUSINESS LICENSE NUMBER
BUILDING PLANNING ENGINEERING FIRE GREEN I SMIP
INVOICE y/L �D PAID AMOUNT 0
AMOUT -1�J CASH CHECK# OCREDIT CARD VISA/MC
PLAN CHECK FEES PAIDAMOUNT OCASH OCHECK# OCREDITCARD VISA/Mc
OWNER BUILDER VERIFIED O YES O NO DL NUMBER NOTARIZED LETTER O YES O NO
City of Menifee Building&Safety Department 29714 Haun Rd. Menifee, CA 92586 951-672-6777
www.cityofinenifee.us Inspection Request Line 951-246-6213
SYSTEM INFORMATION BUYER ACKNOWLEDGES THAT THE SOLAR MODULES TO BE INSTALLED
ITEM OTY MFR. MODEL ON THE ROOF OF THE HOME WILL BE SUBSTANTIALLY IN THE
SYSTEM SIZE 2.92KW LOCATIONS INDICATED BY THE ILLUSTRATION,
MODULE 1 II PCS.j HYUNDAI I HIS-S265RG(265W) BUYER:
INVERTER 1 II PCS.1 ENPHASE I M215-60-2LL-S22-IG
ROOF TYPE TILE W/COMPOSITE SHINGLE UNDER ARRAY DATE-
SUB-ARRAY INFORMATION
ARRAY#I ARR
AY#2 ARRAY#3
MOD OTY II NA NA BUYER: 1 M NIFI
TILT 23" NA' NA'
AZIMUTH 186' 1 NA' I NA- DATE:
SWUM ND
City of Menifee ? " f� APP VA
Building Dept
DEC 2 1 2015 REVIEWED 30
Received
19'-6'ARRAY
SOLADECK WIRE "Approval of these p ans sha
b'-W2' 20'-4'FLASHING TRANSITION BOX approval of,any violi tion of,
(UNDER ARRAY)
regulations and ordir ances.
jobsite until completi n,
t I
I
I I
- I I
I { I I
I I I
I I I
PV AC DISCONNECT
EXTERIOR-GARAGE
L—————— UTILITY METER
MAIN SERVICE PANEL
1p (VERIFIED BY BUILDER)
NOTE:DIMENSIONS ARE SHOWN IN PLANE OF ROOF
PLAN 2399 ELEVATION R REVERSE
ORIENTATION 3 LOT#97
LENNAR: ORIGINAL BY: BRI MORRIS DATE:15.11.11
CAMELLIA AT 980 MONTECITO DRIVE.#302 REVIEWED BY:JIMMY METER DATE:IS.II.II
THE LAKES CORONA,CA 92879 REV.# BY DATE I DESCRIPTION
nomosG6
sovnv
DWG TITLE: PAGE#: SCALE: SITE LOCATION:
INDIVIDUAL 4571 Broadway COStreet
29701 ELMSWOOD CIRCLE Boulder,
3D3,4
PLOT PLAN I/16'= I'-0' MENIFEE,CA 3IX1.44L0.400
SYSTEM LAYOUT
MODULE SPECS AND CALCULATIONS INVERTER SPECS AND CALCULATIONS
ITEM NOTE/CALC UNIT DETAIL ITEM NOTE/CALC UNIT DETAIL
LOCATION MENIFEE,CA INV. MAKE INVERTER SPEC ENPHASE
TEMP.AMBIENT HIGH(TMAX) ASHRAE 2% °C 37 INV. MODEL INVERTER SPEC M215-60-2LL-S22-IG
TEMP.AMBIENT LOW(THIN) ASHRAE EXTR.MIN 'C -2 INV. MAX POWER.(WAC MAX) INVERTER SPEC WATTS(AC) 225
TEMP,MODULE TEST(TTEST) MODULE SPEC 'C 25 INV. INPUT V.(VOC MAX) INVERTER SPEC VOLTS(0c) 48
TEMP,DELTA LOW(TOELTA) THIN-TTEST °C -27 INV. OUTPUT V.(VAC NOM) INVERTER SPEC VOLTS(AO) 240
MOD.MANUFACTURER MODULE SPEC HYUNDAI INV. OUTPUT FREQUENCY INVERTER SPEC HERTZ 60
MOD.PART NUMBER MODULE SPEC HIS-S265RG INV. OUTPUT CURRENT,IAC INVERTER SPEC AMPS(AC) 0.9
MOD.POWER STC(P) MODULE SPEC WATTS(OC) 265 INV. PHASE QUANTITY INVERTER SPEC PHASE I
MOD.POWER PTC MODULE SPEC WATTS(00 238 COMPLIANCE INVERTER SPEC LIU74111EEE1547
MOD.OPERATING VOLTAGE(VMP) MODULE SPEC VOLTS(OC) 31.30 INV. GROUNDING INVERTER SPEC ISOLATED
MOD.OPEN CCT.VOLTAGE(VOC) MODULE SPEC M14.06
) 38.10 INV. OTY.MAX/BRANCH CCT. INVATYBC OTY II '�/
MOD.COEFF. VOLT/TEMP(COEF) MODULE SPEC -0.IIL BRANCH CCT.OUTPUT,IMA%eC (IAC INV.QTYBC) AMPS(AG) 9:90 ' r
MOD.MAX VOLTAGE(VMAXMOO) (VOC+(TO•COEF)) ) 4IJ8 INV. QUANTITY,TOTAL INV.QTYT OTY II
MOD.OPERATING CURRENT(IMP) MODULE SPEC 8.50 TOTAL SYSTEM OUTPUT,IMAM (IAC°INV.QTYT) AMPS(AC) 9.90
MOD.SHORT CCT.CURRENT OSG) MODULE SPEC ) 9.00
MOD.MAXIMUM CURRENT OMAx) (IS[• 1.25) ) 11.25
MIN.AMPACITY REG'D.PER NEC (IMAX-1.25) ) 14.06SERIES FUSE RATING,MAX MODULE SPEC 7 15
ELECTRICAL EQUIPMENT SCHEDULE
KEY OTY MANUFACTURER MODEL NOTES TRADE
1 II HYUNDAI HIS-S265RG(265W) PV MODULE SOLAR
2 It ENPHASE M215-60-2LL-S22-IG PV INVERTER SOLAR
3 1 RSTC/SOLADECK 0786-3R5 PV ROOF JUNCTION BOX.NEMA 3R SOLAR 't t) COnstn
4 I CUTLER-HAMMER DG221URB PV AC DISCONNECT,NEMA 3R,240V,30A SOLAR
5 1 ENPHASE ENVOY PV DATA MONITOR,120V SOLAR prol isions o
6 1 TBD TBD 120V DEDICATED RECEPTACLE FOR ENVOY PV DATA MONITOR SOLAR 1 set f apprc 7 1 TBD TBD CATS PORT FOR SOLAR PV INTERNET CONNECTION TO HOME NETWORK BOX SOLAR
8 NOTE CUTLER-HAMMER TBD PV BRANCH CIRCUIT BREAKERS: I X 15A-IP(ENVOY) SOLAR
9 NOTE CUTLER-HAMMER TBD PV BREAKER,I x 20A-ZP.LOCATE AT OPPOSITE END OF BUS FROM MAIN BREAKER SOLAR
10 I TBD TBD SERVICE PANEL,MIN. 125A BUS BLDR.ELEC.
II I TBD TBD UTILITY METER.MIN.
120/240V,ZOOA BLOR.ELEC.
12 1 I 1 TBD I TBD I GROUNDING ELECTRODE UFER BLOB.ELEC.
CONDUCTOR SIZING CALCULATIONS INTERCONNECTION CALCULATIONS
U CONDITION OF USE(COU): (AMPACITY•TEMP.DERATE'FILL DEBATE)V .REO'D(IMAX) ITEM UNIT PANEL
2)TERMINALS(TERM): AMPACITY AT TERMINALS.vs.REQ'D,(IMAX• 1.25) PANEL MFR. CUTLER-HAMMER
KEY SIZE CU/AL INSULATION CALL' AMPACITY W/O TEMP. FILL W22.80
O'D OCD BUS RATING AMPS 200
TYPE DERATES DERATE DERATE USED(A) MAIN DISCONNECT AMPS 200
A #12 CU THWN-2 COU 30 0.7 11.0 0 ALLOWED PV PER NEC AMPS 40
TERM 25 8 20 PV OCPD DEVICE USED AMPS 20
B *10 CU NM-B COU 40 0.91 1.0 0TERM 35 8 20C #10 CU NM-B COU 40 0.91 L0 0TERM 35 8 20
CONDUCTOR SCHEDULE
KEY 1 CONDUCTORS CU/AL TYPE LOCATION TRADE
#12 ENGAGE CABLE,1 A _WIZ ENGAGE FREE AIR CU TC-ER ARRAY SOLAR
B I 3-#10,1-#10 EGC I CU I NM-B(ROMEX) INTERIOR SOLAR
C 3-#10.1-#10 EGC CU NM-B(ROMEX) INTERIOR SOLAR 5 6 II
p I CAT5E.ETHERNET CABLE I CU I CATSE INTERIOR SOLAR 7 o 0
I M —
SEE NOTE 15 10
O 8
4
15AlIP
0 9
O 30PN
3 '
G G—�
A B C — 12
I I I
ROOF EXTERIOR-GARAGE
ELECTRICAL DIAGRAM 2.92 KW
LOT#97
ORIGINAL BY: BRI MORRIS DATE:I5.11.11
CAMELLIA AT LENNAR:
980 MONTECITO DRIVE,#302 REVIEWED BY:JIMMY METER I DATE:15.11.11
THE LAKES CORONA,CA 92879 REV.# BY DATE DESCRIPTION
Oniamast;6
{4LL[
DWG TITLE: PAGE#: SCALE: SITE LOCATION:
reirt
INDIVIDUAL 9Bo &O,CO8 D4
PLOT PLAN 2 NITS 29701 ELMSW000 CIRCLE Boulder,C030304
ELECTRICAL MENIFEE.CA 303.947.0300
STRUCTURAL NOTES:
SOLAR CONTRACTOR-
U ALL PV ROOF ATTACHMENTS WILL BE SPACED ALONG MODULE RACKING RAILS AT NOT GREATER THAN 48'O.C.
2)ALL PV ROOF ATTACHMENTS WILL BE STAGGERED BY ROW AMONGST THE ROOF FRAMING MEMBERS,TO MAXIMUM EXTENT POSSIBLE.
3)ROOF PENETRATIONS ASSOCIATED WITH SOLAR RACKING WILL BE SEALED WITH AN APPROVED SEALANT.
4)SOLADECK WIRE TRANSITION BOX WILL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS. IT WILL BE FLASHED AND SEALED.
5)PV ARRAY WILL BE A MINIMUM OF 3'ABOVE THE COMPOSITE SHINGLE ROOF SURFACE.
6)THE UNIRAC SOLARMOUNT RACKING SYSTEM AND SOLAR PV ARRAY WILL BE INSTALLED ACCORDING TO THE UNIRAC SOLARMOUNT CODE-COMPLIANT INSTALLATION
MANUAL,VERSION 227.3,PUB 140113-ICC,JANUARY 2014.
7)UNIRAC TOP CLAMPS REQUIRE A ONE INCH 01 SPACE BETWEEN PV MODULES.SOLARMOUNT RAILS MUST EXTEND A MINIMUM OF TWO INCHES(29 BEYOND THE EDGE
OF THE PV ARRAY/SUB-ARRAY.
8)UNIRAC SOLARMOUNT REQUIRES THAT A THERMAL EXPANSION GAP BE INSTALLED FOR ANY RAIL LENGTH OF GREATER THAN 40'.ROOFING CONTRACTOR- •p
AR MEN
U DISTANCE BETWEEN ARRAY EDGE AND TRANSITION FLASHING(COMPOSITION TO TILE)WILL BE A MINIMUM OF 3%
2)26 GAUGE INTERLOCKING FLASHING'SIDEWALL'TO BE INSTALLED ALONG THE LENGTH OF THE PV ARRAY AT ROOFING MATERIAL TRANSITION. IT SHALL BE
APROVED PRIOR TO PV SYSTEM INSTALLATION.
3)PEEL-N-STICK BASE TO BE INSTALLED ONE FOOT W)OR MORE BEYOND THE EDGE OF THE COMPOSITION SHINGLE.DOWN TO THE ROOF EAVE.PEEL-N-STICK BASE To
BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS.
4)AREAS.UNDER EACH PV ARRAY SHALL BE ROOFED WITH COMPOSITION SHINGLE.COMPOSITION SHINGLE SHALL RUN FROM ABOVE THE PV ARRAY TO.THE ROOF EA
5)TILE INSTALLED BELOW THE ARRAY TO BE INSTALLED ABOVE THE COMPOSITION ROOF PER ROOFER SPECIFICATIONS.
6)BIRDSTOP WILL BE INSTALLED AT THE UPPERMOST TRANSITION FROM TILE TO COMPOSITION SHINGLE.BIRDSTOP TO BE SPECIFIED BY ROOFER PRIOR Tor .Y
INSTALLATION. -
Dbea r ermitfor,
federal state or
ELECTRICAL NOTES: I plans Ir ust be keI
GENERAL-
1)ALL PV EQUIPMENT WILL BE TESTED AND LISTED FOR ITS USE BY A NATIONALLY RECOGNIZED TESTING LABORATORY(NRTL).
2)THE GROUNDING OF THE PHOTOVOLTAIC SYSTEM SHALL COMPLY WITH THE APPLICABLE VERSION OF THE NEC/CEC.
3)ALL GROUNDING ELECTRODE CONDUCTORS WILL BE INSTALLED IN A CONTINUOUS LENGTH EXCEPT WHERE SPLICED BY AN IRREVERSIBLE CONNECTOR OR EXOTHERMIC
WELD.
4)NON-CURRENT CARRYING METAL PARTS SHALL BE CHECKED FOR PROPER GROUNDING,NOTING THAT TERMINAL LUGS BOLTED ON AN ENCLOSURE'S FINISHED SURFACE
MAY BE ELECTRICALLY INSULATED BECAUSE OF PAINT/FINISH. PAINT/FINISH AT POINT OF CONTACT SHALL BE PROPERLY REMOVED.
5)ROOF PENETRATIONS WILL BE COMPLETED AND SEALED PER APPLICABLE CODE.
6)ALL CONDUCTORS WILL HAVE A 90'C RATING TO ENSURE CODE COMPLIANCE.
SOLAR CONTRACTOR-
7)MODULE CERTIFICATIONS WILL INCLUDE 1.11-1703,IEC61646,IEC61730.
8)CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS.
9)RACEWAY POINT OF PENETRATION FROM EXTERIOR TO INTERIOR WILL BE SEALED TO PREVENT INGRESS of WATER AND INSECTS.
10)DC WIRING IS LIMITED TO PV ARRAY FOOTPRINT W/ENPHASE MICRO-INVERTER SYSTEM.
IU MODULE AND ENPHASE WIRING SHALL BE LOCATED AND SECURED UNDER THE ARRAY USING SUITABLE WIRING CLIPS.WIRING SHALL NOT MAKE CONTACT WITH THE
ROOF SURFACE AND SHALL BE MANAGED IN A WORKMAN-LIKE MANNER.
12)EQUIPMENT GROUNDING CONDUCTORS WILL BE SIZED IN ACCORDANCE WITH NEC TABLE 250.122.
13)CONDUCTOR TERMINATIONS WILL BE TORQUED PER DEVICE LISTING,OR MANUFACTURER'S RECOMMENDATIONS.
14)A PV AGGREGATION PANEL(SUB PANEL)WILL NOT BE INCLUDED FOR SYSTEMS WITH ONE BRANCH CIRCUIT.
15)A DEDICATED 120V BRANCH CIRCUIT 15 REQUIRED IN MASTER CLOSET(OR EQUIVALENT)FOR ENPHASE ENVOY MONITOR.
SIGNAGE-
16)PV SYSTEMS SHALL BE CLEARLY MARKED IN ACCORDANCE WITH NEC ARTICLE 690 AND OTHER APPLICABLE STATE AND LOCAL CODES.
17)ALL SAFETY MARKING/PLACARDS SHALL BE PERMANENTLY ATTACHED BY ADHESIVE OR OTHER MECHANICAL MEANS.
18)MARKING/PLACARDS WILL BE METAL OR PLASTIC WITH ENGRAVED OR MACHINE PRINTED LETTERING.BACKGROUND WILL BE RED WITH WHITE CAPITAL LETTERING OF
MINIMUM HEIGHT e.
19)ALL WIRING/RACEWAYS/JUNCTION BOXES WILL BE MARKED'PHOTOVOLTAIC POWER SOURCE;OR EQUIVALENT:WIRING/RACEWAYS SHALL BE MARKED EVERY 10'.
BUILDER ELECTRICAL AND SOLAR CONTRACTORS-
20)INSTALLATION SMALL BE COMPLETED IN A NEAT AND WORKMAN-LIKE MANNER.
21)SPACE REQUIREMENTS FOR ALL ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110.26.
LENNAR: ORIGINAL BY: BRI MORRIS DATE:15.11.11
CAMELLIA AT 980 MONTECITO DRIVE,#302 REVIEWED BY:JIMMY METER DATE:15.11.11
THE LAKES CORONA,CA 92879 REV.# BY DATE DESCRIPTION •�
nama Ste
DWG TITLE: PAGE 4: SCALE: SITE LOCATION:
INDIVIDUAL 4571 Broadway Street
PLOT PLAN 3 NTS 29701 ELMSWOOD CIRCLE Boulder.CO 803U
NOTES MENIFEE.CA 303.447,0300
CAUTION:
POWER TO THIS BUILDING IS SUPPLIED BY THE
UTILITY AND A SOLAR PV SYSTEM. DISCONNECTS
ARE LOCATED AS SHOWN.
wLecea wwe
mwsmaX eox
RvmEa saRRry '
gar
an
In the
Rv<c mscoueLc
ExrERloa-cuemE
urlLm�rtrtREa e
X RI SERVILE 1Y
(VERIFl RN Ee BV LOFA)
SERVICE BY QUALIFIED PERSONNEL ONLY
CONTACT: SUNSTREET ENERGY GROUP
1-877-SLR-POWR
PV POWER SOURCE - AC SPECS
AC OPERATING VOLTAGE: 240 V
AC OPERATING CURRENT: 9.9 A
NOTE: SEE MASTER SET FOR ADDITIONAL PLACARD INFORMATION
ORIGINAL BY: BRI MORRIS DATE:15.11.11
CAMELLIA AT LENNAR:
980 MONTECITO DRIVE.#302 REVIEWED BY:JIMMY METER DATE:15.11.11
THE LAKES CORONA,CA 92879 REV.# BY DATE DESCRIPTION tit
masGe
so Eev
DWG TITLE: PAGE#: SCALE: SITE LOCATION: 4571 Bmdway Stmel
INDIVIDUAL 29701 ELMSWOOD CIRCLE B.I&r,CO 80304
PLOT PLAN A NTS PLACARDS MENIFEE,CA 303.497.0300