Loading...
PMT15-03903 City of Menifee Permit No.: PMT15-03903 29714 HAUN RD. Type: Residential Electrical <A—CCEU/ MENIFEE, CA 92586 MENIFEE Date Issued: 1 212 3/2 01 5 PERMIT Site Address: 29717 ELMSWOOD CIR, MENIFEE, CA Parcel Number: 92584 Construction Cost: $6,943.00 Existing Use: Proposed Use: Description of SOLAR TR 30422-3 CAMELLIA Work: 10 MODULES 2.65KW LOT 96 Owner Contractor LENNAR HOMES OF CA LENNAR HOMES OF CALIFORNIA INC 980 MONTECITO DR 9302 25 ENTERPRISE CORONA, CA 92879 ALISO VIEJO, CA 92656 Applicant Phone:9493498269 JEREMIAH ACAYTURRI License Number: 728102 LENNAR HOMES OF CALIFORNIA INC 25 ENTERPRISE ALISO VIEJO,CA 92656 Fee Description Qtv Amount f$1 Solar, Residential or Small Commercial 1 252.00 Building Permit Issuance 1 27.00 GREEN FEE 1 1.00 SMIP RESIDENTIAL 1 1.00 General Plan Maintenance Fee-Electrical 1 12.60 $293.60 The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and specifications or from preventing builiding operations being carried on thereunder when in violation of the Building Code or of any other ordinance of City of Menifee.Except as otherwise stated,a permit for construction under which no work is commenced within six months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be forfeited. AA_Bldg_Permit_Template.rpt Page 1 of 1 BUILDINGAPPLICATION 4 11'=�Menifee DATE 12/15/2016 PERMIT/PLAN CHECK NUMBER �1� 1 l )J� ✓ l�� TYPE: ❑COMMERCIAL ❑✓ RESIDENTIAL ❑MULTI-FAMILY ❑MOBILEHOME POOL/SPA []SIGN SUBTYPE: ❑✓ ADDITION []ALTERATION []DEMOLITION ❑ELECTRICAL [-I MECHANICAL ❑NEW ❑PLUMBING [-I RE-ROOF-NUMBER OF SQUARES DESCRIPTION OF WORK Solar Permit-Plan 2077-2.65 kW/10 PCS Master Solar Permit No. PMT14-02630 PROJECT ADDRESS 29717 Elmswood, Menifee, CA 92584 ASSESSOR'S PARCEL NUMBER LOT 96 TRACT 30422-3 PROPERTY OWNER'S NAME Lennar Homes of California, Inc. ADDRESS 980 Montecito Dr.,Suite 302,Corona,CA 92879 PHONE (951)817-3680 EMAIL jeremiah.acayturri@lennar.com APPLICANT NAME Lennar Homes of California, Inc. ADDRESS 980 Montecito Dr.,Suite 302, Corona, CA PHONE (951)817-3680 EMAIL jeremiah.acayturri@lennar.com CONTRACTOR'S NAME Lennar Homes of California, Inc. OWNER BUILDER? ❑✓ YES❑NO BUSINESS NAME Lennar Homes of California, Inc. ADDRESS 980 Montecito Dr.,Suite 302, Corona,CA PHONE (951)817-3680 EMAIL leremiah.acayturri@lennar.cwm CONTRACTOR'S STATE LIC NUMBER 728102 LICENSE CLASSIFICATION A&B VALUATION$ $6,943.00 SO FT SQ FT APPLICANT'S SIGNATURE DATE 12/15/2015 CITY STAFF USE ONLY DEPARTMENT DISTRIBUTION f� I CITY OF MENIFEE BUSINESS LICENSE NUMBER BUILDING PLANNING ENGINEERING FIRE GREEN SMIP INVOICE �0h (yO PAID AMOUNT C AMOUNT l QCASH 0CHECKN CREDITCARD VISA/MC PLAN CHECK FEES PAID AMOUNT O CASH O CHECKN O CREDITCARD VISA/MC OWNER BUILDER VERIFIED O YES 0 No DL NUMBER NOTARIZED LETTER D YES C NO City of Menifee Building&Safety Department 29714 Houn Rd. Menifee, CA 92586 951-672-6777 www.cityofinenifee.us Inspection Request Line 951-246-6213 SYSTEM INFORMATION BUYER ACKNOWLEDGES THAT THE SOLAR MODULES TO BE INSTALLED ITEM OTY MFR. MODEL ON THE ROOF OF THE HOME WILL BE SUBSTANTIALLY IN THE SYSTEM SIZE 2.65 KW LOCATIONS INDICATED BY THE ILLUSTRATION. MODULE 1 IO PCS.1 HYUNDAI I HIS-5265RG(265W) BUYER: INVERTER 1 10 PCS.1 ENPHASE I MZIS-60-2LL-522-IG ROOF TYPE I TILE W/COMPOSITE SHINGLE UNDER ARRAY DATE: SUB-ARRAY INFORMATION ARRAY#1 ARRAY#2 ARRAY#3 LITY OF ME IFEI MOD OTY 10 MA NA BUYER: TILT 23' NA' NA' 'II nfNG A D S AZIMUTH 126• NA• NA' DATE: ;5 i,r City of Menifee i LAN APPROVAL Building Dept DEC 2 12015 C ENT+_WED SOLADECK WIRE Received `(DproYal of these pla is shall TRANSITION BOX 16'-3-ARRAY ` ,oval of any Vlolat n of al (UNDER ARRAY) IT-(-FLASHING 1, 6'-D14' r ngulations and ordina ices, T ------- ------------ jDhslte until completio i. } I I M I I I I I I I I PV AC DISCONNECT ' EXTERIOR-GARAGE — UTILITY METER a I MAIN SERVICE PANEL (VERIFIED BY BUILDER) L—— _ ———J L O coo NOTE:DIMENSIONS ARE SHOWN IN PLANE OF ROOF PLAN 20-7 ELEVATION C ORIENTATION 3 LOT#96 ORIGINAL BY: SRI MORRIS DATE:15.11.11 CAMELLIA AT LENNAR: 980 MONTECITO DRIVE,#302 REVIEWED BY:JIMMY METER I DATE:15.11.11 µ THE LAKES CORONA,CA 92B79 REV.# BY DATE DESCRIPTION Vniamasrd sour DWG TITLE: PAGE#: SCALE: SITE LOCATION: 4571 Broadway Street INDIVIDUAL 29717 ELMSWOOD CIRCLE Boulder,CO 80304 PLOT PLAN 1/16'=I'-0' MENIFEE,CA 303.447.0300 SYSTEM LAYOUT MODULE SPECS AND CALCULATIONS INVERTER SPECS AND CALCULATIONS ITEM NOTE/CALC UNIT DETAIL ITEM NOTE/CALC UNIT DETAIL LOCATION MENIFEE.CA INV. MAKE INVERTER SPEC ENPHASE TEMP,AMBIENT HIGH(TMAX) ASHRAE 2% 'C 37 INV. MODEL INVERTER SPEC M215-60-2LL-522-lG TEMP,AMBIENT LOW(THIN) ASHRAE EXTR.MIN 'C -2 INV. MAX POWER.(WAC MAX) INVERTER SPEC WATTS(AC) 225 TEMP.MODULE TEST(TTEST) MODULE SPEC •C 25 INV. INPUT V.(VDC MAX) INVERTER SPEC VOLTS(DO 48 TEMP.DELTA LOW(TDELTA) THIN-TTEST •C -27 INV.OUTPUT V.(Vac MOM) INVERTER SPEC VOLTS(AC) 240 MOD.MANUFACTURER MODULE SPEC HYUNDAI INV.OUTPUT FREQUENCY INVERTER SPEC HERTZ 60 MOD.PART NUMBER MODULE SPEC HIS-S265RG INV.OUTPUT CURRENT,IAC INVERTER SPEC AMPS(AO) 0.9 MOD.POWER STC(P) MODULE SPEC WATTS(Uc) 265 INV.PHASE QUANTITY INVERTER SPEC PHASE I MOD.POWER PTC MODULE SPEC WATTS(Oc) 236 COMPLIANCE INVERTER SPEC UL1741/IEEE1547 TM MOD.OPERATING VOLTAGE(VMP) MODULE SPEC VOLTS 00 31.30 INV.GROUNDING INVERTER SPEC ISOLATED MOD.OPEN CCT.VOLTAGE(VOC) MODULE SPEC VOLTS(0C) 38.10 INV.OTY,MAX/BRANCH CCT. INV.QTY'C OTY 10 MOD.COEFF. VOLT/TEMP(CLEF) MODULE SPEC V/•C -0.114 BRANCH CCT.OUTPUT,IHA%BC I 0AC'INV.GTY80 I AMPS(AC) 1 9.00 MOD. MAX VOLTAGE(VMAXMOO) (VOC•(TO'COEF)) VOLTS(DC) 41.18 INV.QUANTITY,TOTAL INV.QTYT OTY 10 MOD.OPERATING CURRENT(IMP) MODULE SPEC AMPS(DC) 8.50 TOTAL SYSTEM OUTPUT,IMAXTS (IAC•INV.QTYT) AMPS(AC) 9.00 MOD.SHORT CCT.CURRENT INC) MODULE SPEC AMPS(DC) 9.00 MOD.MAXIMUM CURRENT(1MAX) (I5c•1.25) AMPS(DC) 11.25 MIN.AMPACITY REO'D,PER NEC (IMAX- 1.25) AMPS(a) 14.06 SERIES FUSE RATING,MAX MODULE SPEC AMPS(DO) 15 ELECTRICAL EQUIPMENT SCHEDULE KEY OTY MANUFACTURER MODEL I NOTES TRADE 1 10 HYUNDAI HIS-S265RG(265W) PV MODULE SOLAR b constrl 2 10 ENPHASE M215-60-21-L-S22-IG PV INVERTER SOLAR 3 1 RSTC/SOLADECK 0786-3R5 PV ROOF JUNCTION BOX,NEMA 3R SOLAR 1'0 fisions c 4 1 CUTLER-HAMMER DG221URB PV AC DISCONNECT,NEMA 3R.24OV,30A SOLAR Pt Of 3 5 1 ENPHASE ENVOY PV DATA MONITOR, 120V SOLAR FPfl 6 1 TBD TBD 120V DEDICATED RECEPTACLE FOR ENVOY PV DATA MONITOR SOLAR 7 1 TBD TBD CAT5 PORT FOR SOLAR PV INTERNET CONNECTION TO HOME NETWORK BOX SOLAR 8 NOTE CUTLER-HAMMER TBD PV BRANCH CIRCUIT BREAKERS:I x 15A-IP(ENVOY) SOLAR 9 NOTE CUTLER-HAMMER TBD PV BREAKER,I X 20A-2P.LOCATE AT OPPOSITE END OF BUS FROM MAIN BREAKER SOLAR 10 I TBD TBD SERVICE PANEL.MIN. 125A BUS BLOB.ELEC. II TBD TBD UTILITY METER,IPH.120/24OV,200A BLDR.ELEC. 12 1 TBO TBD GROUNDING ELECTRODE UFER I BLDR.ELEC. CONDUCTOR SIZING CALCULATIONS INTERCONNECTION CALCULATIONS 1)CONDITION OF USE(COU): (AMPACITY•TEMP.BERATE •FILL DEBATE)VB.REG'D(IMAX) ITEM UNIT PANEL 2)TERMINALS(TERM): AMPACITY AT TERMINALS.VB.REQ'D.(IMAX- 1.25) PANEL MFR. CUTLER-HAMMER KEY SIZE CU/AL INSULATION CALC. AMPACITY W70 TEMP. FILL RESULT 'REQ'D OCD BUS RATING AMPS 200 TYPE BERATES DERATE DEBATE (A) (A) USED(A) MAIN DISCONNECT AMPS 200 A #12 CU THWN-2 COU 30 0.76 1 1.0 22.80 9.00 ALLOWED PV PER NEC AMPS 40 TERM 25 25 11.25 20 PV OCPD DEVICE USED AMPS 20 B #10 CU NM-B COU 40 0.91 1.0 36.40 9.00 TERM 35 35 11.25 20 C #10 CU NM-B COU 40 0.91 1.0 36.40 9.00 TERM 35 35 11.25 20 CONDUCTOR SCHEDULE KEY CONDUCTORS 1 CU/AL 1 TYPE LOCATION TRADE A L#12 ENGAGE CABLE, -#6G,FREE AIR CU TC-ER ARRAY SOLAR B 3-#10.I-#10 EEC 1 CU I NM-B(ROMEX) I INTERIOR I SOLAR C 13410.1-#10 EGC I Cu I NM-B(ROMEX) I INTERIOR I SOLAR 5 6 II D I CAT5E.ETHERNET CABLE I Cu I CAT5E I INTERIOR I SOLAR c n O I SEE NOTE 15 0 ' O 0 9 O I N 3 _ T LLL GGB _12 ROOF EXTERIOR-GARAGE ELECTRICAL DIAGRAM 2.65 XW LOT#96 LENNAR: ORIGINAL BY: SRI MORRIS I DATE:I5.11.11 CAMELLIA AT 980 MONTECITO DRIVE,#302 REVIEWED BY:JIMMY METER I DATE:15.11.11 THE LAKES CORONA,CA 92879 REV.# BY DATE DESCRIPTION namasb6 XOCAv DWG TITLE: PAGE#: SCALE: SITE LOCATION: INDIVIDUAL 4B ml 'C ffl tr I PLOT PLAN 2 NTS 29717 ELMSWOOD CIRCLE BO303.4 7030009 ELECTRICAL MENIFEE,CA 303.447.0300 STRUCTURAL NOTES: SOLAR CONTRACTOR- U ALL PV ROOF ATTACHMENTS WILL BE SPACED ALONG MODULE RACKING RAILS AT NOT GREATER THAN 48'O.C. 2)ALL PV ROOF ATTACHMENTS WILL BE STAGGERED BY ROW AMONGST THE ROOF FRAMING MEMBERS.TO MAXIMUM EXTENT POSSIBLE. 3)ROOF PENETRATIONS ASSOCIATED WITH SOLAR RACKING WILL BE SEALED WITH AN APPROVED SEALANT. 4)SOLADECK WIRE TRANSITION BOX WILL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS. IT WILL BE FLASHED AND SEALED. 5)PV ARRAY WILL BE A MINIMUM OF 3'ABOVE THE COMPOSITE SHINGLE ROOF SURFACE. 6)THE UNIRAC SOLARMOUNT RACKING SYSTEM AND SOLAR PV ARRAY WILL BE INSTALLED ACCORDING TO THE UNIRAC SOLARMOUNT CODE-COMPLIANT INSTALLATION MANUAL,VERSION 227.3,PUB 140113-ICC,JANUARY 2014. PA RTMI 7)UNIRAC TOP CLAMPS REQUIRE A ONE INCH(I')SPACE BETWEEN PV MODULES.SOLARMOUNT RAILS MUST EXTEND A MINIMUM OF TWO INCHES(2')BEYOND THE EDGE OF THE PV ARRAY/SUB-ARRAY. 8)UNIRAC SOLARMOUNT REQUIRES THAT A THERMAL EXPANSION GAP BE INSTALLED FOR ANY RAIL LENGTH OF GREATER THAN 40'. ROOFING CONTRACTOR- D DISTANCE BETWEEN ARRAY EDGE AND TRANSITION FLASHING(COMPOSITION TO TILE)WILL BE A MINIMUM OF 3. 2)26 GAUGE INTERLOCKING FLASHING'SIDEWALL-TO BE INSTALLED ALONG THE LENGTH OF THE PV ARRAY AT ROOFING MATERIAL TRANSITION. IT SHALL BE APROVED PRIOR TO PV SYSTEM INSTALLATION. 3)PEEL-N-STICK BASE TO BE INSTALLED ONE FOOT(I')OR MORE BEYOND THE EDGE OF THE COMPOSITION SHINGLE,DOWN TO THE ROOF EAVE.PEEL-N-STICK BASE TO BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS. 4)AREAS UNDER EACH PV ARRAY SHALL BE ROOFED WITH COMPOSITION SHINGLE. COMPOSITION.SHINGLE SHALL RUN FROM ABOVE THE PV ARRAY TO THE ROOF EAVE. 5)TILE INSTALLED BELOW THE ARRAY TO BE INSTALLED ABOVE THE COMPOSITION ROOF PER ROOFER SPECIFICATIONS. 6)BIRDSTOP WILL BE INSTALLED AT THE UPPERMOST TRANSITION FROM TILE TO COMPOSITION SHINGLE. BIRDSTOP TO BE SPECIFIED BY ROOFER PRIOR TO INSTALLATION. to e a pem e f decal,st d p ans mull ELECTRICAL NOTES: GENERAL- 1)ALL PV EQUIPMENT WILL BE TESTED AND LISTED FOR ITS USE BY A NATIONALLY RECOGNIZED TESTING LABORATORY(NRTL). 2)THE GROUNDING OF THE PHOTOVOLTAIC SYSTEM SHALL COMPLY WITH THE APPLICABLE VERSION OF THE NEC/CEC. 3)ALL GROUNDING ELECTRODE CONDUCTORS WILL BE INSTALLED IN A CONTINUOUS LENGTH EXCEPT WHERE SPLICED BY AN IRREVERSIBLE CONNECTOR OR EXOTHERMIC WELD. 4)NON-CURRENT CARRYING METAL PARTS SHALL BE CHECKED FOR PROPER GROUNDING,NOTING THAT TERMINAL LUGS BOLTED ON AN ENCLOSURE'S FINISHED SURFACE MAY BE ELECTRICALLY INSULATED BECAUSE OF PAINT/FINISH. PAINT/FINISH AT POINT OF CONTACT SHALL BE PROPERLY REMOVED. 5)ROOF PENETRATIONS WILL BE COMPLETED AND SEALED PER APPLICABLE CODE. 6)ALL CONDUCTORS WILL HAVE A 90-C RATING TO ENSURE CODE COMPLIANCE. SOLAR CONTRACTOR- 7)MODULE CERTIFICATIONS WILL INCLUDE UL1703,IEC61646,IEC61730. 8)CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS. 9).RACEWAY POINT OF PENETRATION FROM EXTERIOR TO INTERIOR WILL BE SEALED TO PREVENT INGRESS OF WATER AND INSECTS. 10)DC WIRING IS LIMITED TO PV ARRAY FOOTPRINT W/ENPHASE MICRO-INVERTER SYSTEM. 11)MODULE AND ENPHASE WIRING SMALL BE LOCATED AND SECURED UNDER THE ARRAY USING SUITABLE WIRING CLIPS.WIRING SHALL NOT MAKE CONTACT WITH THE ROOF SURFACE AND SHALL BE MANAGED IN A WORKMAN-LIKE MANNER. 12)EQUIPMENT GROUNDING CONDUCTORS WILL BE SIZED IN ACCORDANCE WITH NEC TABLE 250.122. 13)CONDUCTOR TERMINATIONS WILL BE TORQUED PER DEVICE LISTING,OR MANUFACTURER'S RECOMMENDATIONS. 14)A PV AGGREGATION PANEL(SUB PANEL)WILL NOT BE INCLUDED FOR SYSTEMS WITH ONE BRANCH CIRCUIT. 15)A DEDICATED 120V BRANCH CIRCUIT IS REQUIRED IN MASTER CLOSET(Oft EQUIVALENT)FOR ENPHASE ENVOY MONITOR. SIGNAGE- 16)PV SYSTEMS SHALL BE CLEARLY MARKED IN ACCORDANCE WITH NEC ARTICLE 690 AND OTHER APPLICABLE STATE AND LOCAL CODES. 17)ALL SAFETY MARKING/PLACARDS SHALL BE PERMANENTLY ATTACHED BY ADHESIVE OR OTHER MECHANICAL MEANS. 18)MARKING/PLACARDS WILL BE METAL OR PLASTIC WITH ENGRAVED OR MACHINE PRINTED LETTERING.BACKGROUND WILL BE RED WITH WHITE CAPITAL LETTERING OF MINIMUM HEIGHT t. 19)ALL WIRING/RACEWAYS/JUNCTION BOXES WILL BE MARKED'PHOTOVOLTAIC POWER SOURCE;OR EQUIVALENT:WIRING/RACEWAYS SHALL BE MARKED EVERY 10'. BUILDER ELECTRICAL AND SOLAR CONTRACTORS- 20)INSTALLATION SHALL BE COMPLETED IN A NEAT AND WORKMAN-LIKE MANNER. 20 SPACE REQUIREMENTS FOR ALL ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110.26. LENNAR: ORIGINAL BY: BRI MORRIS DATE:I5.11.11 CAMELLIA AT 980 MONTECITO DRIVE.#302 REVIEWED BV:JIMMY METER DATE:15.11.11 THE LAKES CORONA,CA 92879 REV.# BY DATE I DESCRIPTION Oamasbili DWG TITLE: PAGE#: I SCALE: SITE LOCATION: 4571 BroaCWay Street INDIVIDUAL 29717 ELMSWOOD CIRCLE Boulder,CO 80304 PLOT PLAN 3 NTS NOTES MENIFEE,CA 303.447.0300 CAUTION: POWER TO THIS BUILDING IS SUPPLIED BY THE UTILITY AND A SOLAR PV SYSTEM. DISCONNECTS IT ARE LOCATED AS SHOWN. mLmEcx r�ax M eax cuaEa eaaev) DATE or,or an or city kept on th PV e[D,..Ecr IRILIIV KCIER 0 M<N SERVILE pNJEL (YFPIFIEO BY&IILMR) SERVICE BY QUALIFIED PERSONNEL ONLY CONTACT: SUNSTREET ENERGY GROUP 1-877-SLR-POWR PV POWER SOURCE - AC SPECS AC OPERATING VOLTAGE: 240 V AC OPERATING CURRENT: 9.0 A NOTE: SEE MASTER SET FOR ADDITIONAL PLACARD INFORMATION ORIGINAL BY: BRI MORRIS DATE:15.11.11 CAMELLIA AT LENNAR: REVIEWED BY:JIMMY METER DATE:15.11.11 COR NA.CA I92 DRIVE.#302 THE LAKES CORONA.CA 92879 REV.# BY DATE DESCRIPTION Vnamcls.. soL,xv DWG TITLE: PAGE#: SCALE: SITE LOCATION: INDIVIDUAL 4571 BOr,CO8 Streel PLOT PLAN 4 NTS 2971P ELMSWOOD CIRCLE eaultler,C080304 PLACARDS MENIFEE,CA 303.447.0300