Loading...
PMT15-03902 City of Menifee Permit No.: PMT16-03902 29714 HAUN RD. Type: Residential Electrical <ACCEL/-> MENIFEE,CA 92586 r.,....�-..<s.�._,. MENIFEE Date Issued: 1 212 3/201 5 PERMIT Site Address: 29726 ELMSWOOD CIR, MENIFEE, CA Parcel Number: 92584 Construction Cost: $8,331.60 Existing Use: Proposed Use: Description of SOLAR TR 30422-3 CAMELLIA Work: 12 MODULES 3.18KW LOT 95 Owner Contractor LENNAR HOMES OF CA LENNAR HOMES OF CALIFORNIA INC 980 MONTECITO DR#302 25 ENTERPRISE CORONA,CA 92879 ALISO VIEJO,CA 92656 Applicant Phone: 9493498269 JEREMIAH ACAYTURRI License Number: 728102 LENNAR HOMES OF CALIFORNIA INC 25 ENTERPRISE ALISO VIEJO, CA 92656 Fee Description Qtv Amount t$1 Solar, Residential or Small Commercial 1 252.00 Building Permit Issuance 1 27.00 GREEN FEE 1 1.00 SMIP RESIDENTIAL 1 2.00 General Plan Maintenance Fee-Electrical 1 12.60 $294.60 The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and specifications or from preventing building operations being carried on thereunder when in violation of the Building Code or of any other ordinance of City of Menifee.Except as otherwise stated,a permit for construction under which no work is commenced within six months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be forfeited. AA_Bldg_Pennit Template.rpt Page 1 of 1 BUILDING & SAFETY PERMIT/PLAN CHECK APPLICATION A Menifee DATE 12/15/2015 PERMIT/PLAN CHECK NUMBER IC7 TYPE: ❑COMMERCIAL ❑✓ RESIDENTIAL ❑MULTI-FAMILY ❑MOBILEHOME ❑POOL/SPA []SIGN SUBTYPE: ❑✓ ADDITION []ALTERATION ❑DEMOLITION [—]ELECTRICAL ❑MECHANICAL []NEW []PLUMBING [:IRE-ROOF-NUMBEROFSQUARES DESCRIPTION OF WORK Solar Permit-Plan 2785-3.18 kW/12 PCS Master Solar Permit No. PMT14-02630 PROJECTADDRESS 29726 Elmswood,Menifee, CA 92584 ASSESSOR'S PARCEL NUMBER LOT 95 TRACT 30422-3 PROPERTY OWNER'S NAME Lennar Homes of California, Inc. ADDRESS 980 Montecito Dr.,Suite 302,Corona,CA 92879 PHONE (951)817-3680 EMAIL jeremiah.acayturri@lennar.com APPLICANT NAME Lennar Homes of California, Inc. ADDRESS 980 Montecito Dr.,Suite 302,Corona,CA PHONE (951)817-3680 EMAIL jeremiah.acayturri@lennar.com CONTRACTOR'S NAME Lennar Homes of California, Inc. OWNER BUILDER? ❑✓ YES❑NO BUSINESS NAME Lennar Homes of California, Inc. ADDRESS 980 Montecito Dr.,Suite 302,Corona, CA PHONE (951)817-3680 EMAIL jeremiah.acayturri@lennar.com CONTRACTOR'S STATE LIC NUMBER 728102 LICENSE CLASSIFICATION A&B VALUATION$ $8,331.60 S q FT APPLICANT'S SIGNATURE DATE 12/15/2015 CITYSTAFF USE ONLY DEPARTMENT DISTRIBUTION CITY OF MENIFEE BUSINESS LICENSE NUMBER BUILDING PLANNING ENGINEERING FIRE I GREEN I..[1 SMIP INVOICE PAIDAMOUNT AMOUNT -I ,. CASH 0 CHECK M 0 CREDIT CARD VISA/MC PLAN CHECK FEES PAIDAMOUNT - CASH OCHECK# 0 CREDIT CARD VISA/MC OWNER BUILDER VERIFIED 0 YES 0 NO DL NUMBER NOTARIZED LETTER 0 YES 0 NO City of Menifee Building&Safety Deportment 29714 Haun Rd. Menifee, CA 92586 951-672-6777 www.cityofinenifee.us Inspection Request Line 951-246-6213 SYSTEM INFORMATION BUYER ACKNOWLEDGES THAT THE SOLAR MODULES TO BE INSTALLED ITEM I OTY MFR. 1 MODEL ON THE ROOF OF THE HOME WILL BE SUBSTANTIALLY IN THE SYSTEM SIZE 3.18 KW LOCATIONS INDICATED BY THE ILLUSTRATION. MODULE 12 PC&I HYUNDAI I HIS-S265RG(263W) BUYER: INVERTER 12 PCS.1 ENPHASE I M215-60-2LL-S22-IG ROOF TYPE I TILE W/COMPOSITE SHINGLE UNDER ARRAY DATE: 77 SUB-ARRAY INFORMATION i_1 I ,� Or M NIFI ARRAY#I ARRAY#2 ARRAY#3 MOD OTY 12 NA NA BUYER: /± TILT 23° NA- NA- i 4 'I- NG ND AZIMUTH 102- NA- NA' DATE: City of Menifee i l.AI'� APP OVA Building pePt o DEC Z 1 '2U15 l ivTWED _ Received 'Acnrovalofthese lanssh acprovalof,anyvio tiond SOLADECK WIRE regulations and ondi antes. 19'-6'ARRAY TRANSITION BOX 6'-(6' 20'-A'FLASHING (UNDER ARRAY) lobsite until comple'on. I I I I PV AC DISCONNECT I EXTERIOR-GARAGE J i I UTILITY METER 8 MAIN SERVICE PANEL (VERIFIED BY BUILDER) � r a NOTE:DIMENSIONS ARE SHOWN IN PLANE OF ROOF \w1 , PLAN 2785 ELEVATION B REVERSE Z ORIENTATION 2 LOT#95 LENNAR: ORIGINAL BY: BRIM MET DATE:I5.11.11 CAMELLIA AT REVIEWED BY:BRI JIMMY METER DATE:15.11.11 980 NA,CA I92 DRIVE,#302 THE LAKES CORONA,LA 92879 REV.# BY DATE DESCRIPTION S. namaste LAR DWG TITLE: PAGE#: SCALE: fO SITE LOCATION: 4577 Bloatlway Street INDIVIDUAL 29726 ELMSWOOD CIRCLE Boulder,CO 80304 PLOT PLAN 1 1/16'=1'-0' MENIFEE,CA 303.447.0300 SYSTEM LAYOUT MODULE SPECS AND CALCULATIONS INVERTER SPECS AND CALCULATIONS ITEM NOTE/CALC UNIT DETAIL ITEM NOTE/CALC UNIT DETAIL LOCATION MENIFEE,CA INV.MAKE INVERTER SPEC ENPHASE TEMP,AMBIENT HIGH(TMAX) ASHRAE 2% •C 37 INV.MODEL INVERTER SPEC M215-60-2LL-S22-IG TEMP,AMBIENT LOW(THIN) ASHRAE EXTR.MIN 'C -2 INV.MAX POWER.(WAc MAX) INVERTER SPEC WATTS(A0 225 TEMP,MODULE TEST(TTEST) MODULE SPEC °C 25 INV. INPUT V.(VoC MAX) INVERTER SPEC VOLTS(00) 48 TEMP.DELTA LOW(TUELTA) THIN-TTEST °C -27 INV.OUTPUT V.(VAC NOM) INVERTER SPEC VOLTS(AC) 240 MOD.MANUFACTURER MODULE SPEC HYUNDAI INV.OUTPUT FREQUENCY INVERTER SPEC HERTZ 60 MOD.PART NUMBER MODULE SPEC HIS-S265RG INV.OUTPUT CURRENT. IAC INVERTER SPEC AMPS(AC) 0.9 O MOD.POWER STC(P) MODULE SPEC WATTS 00 265 INV.PHASE QUANTITY INVERTER SPEC PHASE I MOD.POWER PTC MODULE SPEC WATTS(oc) 238 COMPLIANCE INVERTER SPEC UL1741/IEEE1547 MOD.OPERATING VOLTAGE(VMP) MODULE SPEC VOLTS(00 31.30 INV.GROUNDING INVERTER SPEC ISOLATED MOD.OPEN CCT. VOLTAGE Nod MODULE SPEC VOLTS(GU 38.10 INV.CITY,MAX/BRANCH CCT. INV.QTYac QTY 12 MOD.COEFF.VOLT/TEMP(COEF) MODULE SPEC V/°C -0.114 BRANCH CCT.OUTPUT, IMAXBC (IAC•INV.QTYBC) ji AMPS(AC) 1 10.80 MOD.MAX VOLTAGE(VMAXM00) (Vac r(TD-COEF)) VOLTS(130 41.18 INV.QUANTITY.TOTAL INV.QTYT I OTV 1 12 MOD.OPERATING CURRENT(IMP) MODULE SPEC AMPS(BC) 8.50 TOTAL SYSTEM OUTPUT.IMAXTS (IAC°INV.GTYT) I AMPS(AC) 1 10.80 MOD.SHORT CCT.CURRENT(ISC) MODULE SPEC AMPS(00 9.00 MOD.MAXIMUM CURRENT(TMAX) (ISC• 1.25) AMPS(OC) 11.25 MIN.AMPACITY REO'D,PER NEC (TMAX° 1.25) AMPS(DC) 14.06 SERIES FUSE RATING.MAX MODULE SPEC AMPS(130 15 ELECTRICAL EQUIPMENT SCHEDULE KEY QTY MANUFACTURER MODEL NOTES TRADE 7t be constn 1 12 HYUNDAI HIS-S265RG(265W) PV MODULE SOLAR (pro isions t 2 12 ENPHASE M215-60-2LL-S22-IG PV INVERTER SOLAR 3 1 RSTC/SOLADECK 0786-3R5 PV ROOF JUNCTION BOX,NEMA 3R SOLAR s sel Of appr 4 I CUTLER-HAMMER OG22JURB PV AC DISCONNECT.NEMA 3R,240V.30A SOLAR 5 1 ENPHASE ENVOY PV DATA MONITOR,IZOV SOLAR 6 1 TBD TBD 120V DEDICATED RECEPTACLE FOR ENVOY PV DATA MONITOR SOLAR 7 I TBD TBD CATS PORT FOR SOLAR PV INTERNET CONNECTION TO HOME NETWORK BOX SOLAR 8 NOTE CUTLER-HAMMER TED PV BRANCH CIRCUIT BREAKERS:I x 15A-IP(ENVOY) SOLAR 9 NOTE CUTLER-HAMMER TBD PV BREAKER.I X 2GA-2P,LOCATE AT OPPOSITE END OF BUS FROM MAIN BREAKER SOLAR 10 I TBD TBD SERVICE PANEL,MIN. 125A BUS BLDR.ELEC. II I TBD TBD UTILITY METER.IPH,120/240V.200A BLDR. ELEC. 12 I TBD TBD GROUNDING ELECTRODE UFER I BLDR. ELEC. CONDUCTOR SIZING CALCULATIONS INTERCONNECTION CALCULATIONS 1)CONDITION OF USE(COU): (AMPACITY-TEMP.DERATE•FILL DERATE)VS.REO'D 01 ITEM UNIT PANEL 2)TERMINALS(TERN): I AMPACITY AT TERMINALS.ems.REG-D.(TMAX• 1.25) PANEL MI CUTLER-HAMMER KEY SIZE CU/AL INSULATION CALC. AMPACITY W/0 TEMP. FILL RESULT REO'D OCD BUS RATING AMPS 200 TYPE DERATES DERATE DERATE (A) (A) USED(A) MAIN DISCONNECT AMPS 200 A #12 CU I THWN-2 COU 1 30 0.76 1.0 22.80 10.80 ALLOWED PV PER NEC AMPS 40 TERM 25 25 13.50 20 PV OCPD DEVICE USED AMPS 20 B #10 1 CU I NM-B COU 1 40 0.91 1.0 36.40 10.80 TERM 35 35 13.50 20 ( #10 CU NM-B COU 40 0.91 60 36.40 IO.EO TERM 135 35 13.50 20 CONDUCTOR SCHEDULE K 1 CONDUCTORS CU/AL TYPE LOCATION TRADE A -#12 ENGAGE CABLE, -#6G.FREE AIR CU TC-ER ARRAY SOLAR B 1 3-#10.1-910 EGC I CU I NM-B(ROMEX) INTERIOR SOLAR C 1 3410.1410 EGL I CU NMI(ROMEX) INTERIOR SOLAR D CAT5E.ETHERNET CABLE CU CAT5E INTERIOR SOLAR 5 6 11 O e o a O I SEE NOTE 15 10 O INJR O O 9 O POR/ 3 L 'N 6 G� A B _12 I I I ROOF EXTERIOR-GARAGE ELECTRICAL DIAGRAM 3.18 KW a LOT#95 ORIGINAL BY: BRI MORRIS DATE:15.11.11 CAMELLIA AT LENNAR: 980 MONTECITO DRIVE.#302 REVIEWED BY:JIMMY METER DATE:15.11.11 THE LAKES CORONA,CA 92879 REV.# BY DATE DESCRIPTION Vnamasbib sous DWG TITLE: PAGE*: SCALE: SITE LOCATION: - INDIVIDUAL 4571 Broatlway Street PLOT PLAN 2 NTS 29726 ELMSW000 CIRCLE Boulder,CO 80304 ELECTRICAL MENIFEE.CA 303.447.0300 STRUCTURAL NOTES: SOLAR CONTRACTOR- D ALL PV ROOF ATTACHMENTS WILL BE SPACED ALONG MODULE RACKING RAILS AT NOT GREATER THAN 48'O.C. 2)ALL PV ROOF ATTACHMENTS WILL BE STAGGERED BY ROW AMONGST THE ROOF FRAMING MEMBERS,TO MAXIMUM EXTENT POSSIBLE. 3)ROOF PENETRATIONS ASSOCIATED WITH SOLAR RACKING WILL BE SEALED WITH AN APPROVED SEALANT. 4)SOLADECK WIRE TRANSITION BOX WILL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS. IT WILL BE FLASHED AND SEALED. 5)PV ARRAY WILL BE A MINIMUM OF 3'ABOVE THE COMPOSITE SHINGLE ROOF SURFACE. 6)THE UNIRAC SOLARMOUNT RACKING SYSTEM AND SOLAR PV ARRAY WILL BE INSTALLED ACCORDING TO THE UNIRAC SOLARMOUNT CODE-COMPLIANT INSTALLATION MANUAL,VERSION 227.3.PUB 140113-ICC,JANUARY 2014. 7)UNIRAC TOP CLAMPS REQUIRE A ONE INCH(I')SPACE BETWEEN PV MODULES.SOLARMOUNT RAILS MUST EXTEND A MINIMUM OF TWO INCHES(21 BEYOND THE EDGE OF THE PV ARRAY/SUB-ARRAY. 8)UNIRAC SOLARMOUNT REQUIRES THAT A THERMAL EXPANSION GAP BE INSTALLED FOR ANY RAIL LENGTH OF GREATER THAN 40'. 'A THE ROOFING CONTRACTOR- 1)DISTANCE BETWEEN ARRAY EDGE AND TRANSITION FLASHING(COMPOSITION TO TILE)WILL BE A MINIMUM OF 3. 2)26 GAUGE INTERLOCKING FLASHING'SIDEWALL'TO BE INSTALLED ALONG THE LENGTH OF THE PV ARRAY AT ROOFING MATERIAL TRANSITION. IT SHALL BE APROVED PRIOR TO PV SYSTEM INSTALLATION. 3)PEEL-N-STICK BASE TO BE INSTALLED ONE FOOT(10 OR MORE BEYOND THE EDGE OF THE COMPOSITION SHINGLE.DOWN TO THE ROOF SAVE.PEEL-N-STICK BASE T BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS. t 4)AREAS UNDER EACH PV ARRAY SHALL BE ROOFED WITH COMPOSITION SHINGLE.COMPOSITION SHINGLE SHALL RUN FROM ABOVE THE PV ARRAY TO THE ROOF EAVE. 5)TILE INSTALLED BELOW THE ARRAY TO BE INSTALLED ABOVE THE COMPOSITION ROOF PER ROOFER SPECIFICATIONS. 6)BIRDSTOP WILL BE INSTALLED AT THE UPPERMOST TRANSITION FROM TILE TO COMPOSITION SHINGLE. BIRDSTOP TO BE SPECIFIED BY ROOFER PRIOR TO INSTALLATION. b a permi fei eral,stat d Dias must t ELECTRICAL NOTES: GENERAL- U ALL PV EQUIPMENT WILL BE TESTED AND LISTED FOR ITS USE BY A NATIONALLY RECOGNIZED TESTING LABORATORY(NRTL). 2)THE GROUNDING OF THE PHOTOVOLTAIC SYSTEM SHALL COMPLY WITH THE APPLICABLE VERSION OF THE NEC/CEC. 3)ALL GROUNDING ELECTRODE CONDUCTORS WILL BE INSTALLED IN A CONTINUOUS LENGTH EXCEPT WHERE SPLICED BY AN IRREVERSIBLE CONNECTOR OR EXOTHERMIC WELD. 4)NON-CURRENT CARRYING METAL PARTS SHALL BE CHECKED FOR PROPER GROUNDING,NOTING THAT TERMINAL LUGS BOLTED ON AN ENCLOSURE'S FINISHED SURFACE MAY BE ELECTRICALLY INSULATED BECAUSE OF PAINT/FINISH. PAINT/FINISH AT POINT OF CONTACT SHALL BE PROPERLY REMOVED. 5)ROOF PENETRATIONS WILL BE COMPLETED AND SEALED PER APPLICABLE CODE. 6)ALL CONDUCTORS WILL HAVE A 90°C RATING TO ENSURE CODE COMPLIANCE. SOLAR CONTRACTOR- 7)MODULE CERTIFICATIONS WILL INCLUDE UL1703, IEC61646,IEC61730. B)CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS. 9)RACEWAY POINT OF PENETRATION FROM EXTERIOR TO INTERIOR WILL BE SEALED TO PREVENT INGRESS OF WATER AND INSECTS. 10)DC WIRING IS LIMITED TO PV ARRAY FOOTPRINT W/ENPHASE MICRO-INVERTER SYSTEM. 11)MODULE AND ENPHASE WIRING SHALL BE LOCATED AND SECURED UNDER THE ARRAY USING SUITABLE WIRING CLIPS.WIRING SHALL NOT MAKE CONTACT WITH THE ROOF SURFACE AND SHALL BE MANAGED IN A WORKMANLIKE MANNER. 12)EQUIPMENT GROUNDING CONDUCTORS WILL BE SIZED IN ACCORDANCE WITH NEC TABLE 250.122. 13)CONDUCTOR TERMINATIONS WILL BE TORQUED PER DEVICE LISTING,OR MANUFACTURER'S RECOMMENDATIONS. 14)A PV AGGREGATION PANEL(SUB PANEL)WILL NOT BE INCLUDED FOR SYSTEMS WITH ONE BRANCH CIRCUIT. 15)A DEDICATED 120V BRANCH CIRCUIT IS REQUIRED IN MASTER CLOSET(OR EQUIVALENT)FOR ENPHASE ENVOY MONITOR. SIGNAGE- 16)PV SYSTEMS SMALL BE CLEARLY MARKED IN ACCORDANCE WITH NEC ARTICLE 690 AND OTHER APPLICABLE STATE AND LOCAL CODES. 17)ALL SAFETY MARKING/PLACARDS SHALL BE PERMANENTLY ATTACHED BY ADHESIVE OR OTHER MECHANICAL MEANS. 18)MARKING/PLACARDS WILL BE METAL OR PLASTIC WITH ENGRAVED OR MACHINE PRINTED LETTERING, BACKGROUND WILL BE RED WITH WHITE CAPITAL LETTERING OF MINIMUM HEIGHT pT. 19)ALL WIRING/RACEWAYS/JUNCTION BOXES WILL BE MARKED"PHOTOVOLTAIC POWER SOURCE.'OR EQUIVALENT;WIRING/RACEWAYS SHALL BE MARKED EVERY 10'. BUILDER ELECTRICAL AND SOLAR CONTRACTORS- 20)INSTALLATION SHALL BE COMPLETED IN A NEAT AND WORKMAN-LIKE MANNER. 21)SPACE REQUIREMENTS FOR ALL ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110.26, LENNAR: ORIGINAL BY: BRI MORRIS DATE:I5.11.11 CAMELLIA AT 980 MONTECITO DRIVE,#302 REVIEWED BY:JIMMY METER DATE:15.11.11 THE LAKES CORONA.CA 92879 REV.# BY DATE DESCRIPTION %mast;6 :o"o DWG TITLE: PAGE#: SCALE: SITE LOCATION: INDIVIDUAL 4571 B Street 29726 ELMSWOOD CIRCLE Bo30er,3A CO 80]04 PLOT PLAN 3 NTS NOTES MENIFEE,CA 03.44].0300 CAUTION: POWER TO THIS BUILDING IS SUPPLIED BY THE UTILITY AND A SOLAR PV SYSTEM. DISCONNECTS ARE LOCATED AS SHOWN. T sa LNI'TX lON B N,I SX <OMEa1P6VSIi DAT oran city ept on th 2<c oiscaxEcr rEVIBfl ONUOE ONLY MEYER G NAN SMIM PANEL IVFAiFIFD OY WLL6.0) SERVICE BY QUALIFIED PERSONNEL ONLY CONTACT: SUNSTREET ENERGY GROUP I-877—SLR—POWR PV POWER SOURCE - AC SPECS AC OPERATING VOLTAGE: 240 V AC OPERATING CURRENT: 1o.8 A NOTE: SEE MASTER SET FOR ADDITIONAL PLACARD INFORMATION ORIGINAL BY: BRI MORRIS DATE:15.11.11 CAMELLIA AT LENNAR: 980 MONTECITO DRIVE,#302 REVIEWED BY:JIMMY METER DATE:15.11.11 THE LAKES CORONA.CA 92879 REV.# BY DATE DESCRIPTION •� namasbe SOLAR DWG TITLE: PAGE#: SCALE: SITE LOCATION: INDIVIDUAL 4S71Ider,C 8 304 PLOT PLAN A NTS MENIF ELMBWDDD CIRCLE Boulder,CO B0800 PLACARDS MENIFEE.CA 303.49].0300