PMT15-03901 City of Menifee Permit No.: PMT16-03901
29714 HAUN RD. Type: Residential Electrical
<ACCELA> MENIFEE. CA92586
MENIFEE Date Issued: 12/23/2015
PERMIT
Site Address: 29714 ELMSWOOD CIR, MENIFEE, CA Parcel Number:
92584 Construction Cost: $6,943.00
Existing Use: Proposed Use:
Description of SOLAR TR 30422-3 CAMELLIA
Work: 10 MODULES 2.65KW
LOT 94
Owner Contractor
LENNAR HOMES OF CA LENNAR HOMES OF CALIFORNIA INC
980 MONTECITO DR#302 25 ENTERPRISE
CORONA,CA 92879 ALISO VIEJO, CA 92656
Applicant Phone: 9493498269
JEREMIAH ACAYTURRI License Number:728102
LENNAR HOMES OF CALIFORNIA INC
25 ENTERPRISE
ALISO VIEJO, CA 92656
Fee Description gyt Amount($)
Solar, Residential or Small Commercial 1 252.00
Building Permit Issuance 1 27.00
GREEN FEE 1 1.00
SMIP RESIDENTIAL 1 1.00
General Plan Maintenance Fee-Electrical 1 12.60
$293.60
The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and
specifications or from preventing building operations being carried on thereunder when in violation of the Building Code or of any other
ordinance of City of Menifee.Except as otherwise stated,a permit for construction under which no work is commenced within six
months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be
forfeited.
AA_Bldg_Pennit Templale.rpl Page 1 of 1
SAFETYBUILDING & PERMIT/PLAN CHECK APPLICATION
r'��L'y
Menifee ^'
DATE 12/15/2015 PERMIT/PLAN CHECK NUMBER
TYPE: ❑COMMERCIAL H RESIDENTIAL MULTI-FAMILY ❑MOBILE HOME ❑POOL/SPA ❑SIGN
SUBTYPE: ❑✓ ADDITION ❑ALTERATION ❑DEMOLITION ❑ELECTRICAL [—]MECHANICAL
❑NEW []PLUMBING ❑RE-ROOF-NUMBER OF SQUARES
DESCRIPTION OF WORK Solar Permit-Plan 2077-2.65 kW/10 PCS
Master Solar Permit No. PMT14-02630
PROJECTADDRESS 29714 Elmswood, Menifee, CA92584
ASSESSOR'S PARCEL NUMBER LOT 94 TRACT 30422-3
PROPERTY OWNER'S NAME Lennar Homes of California, Inc.
ADDRESS 980 Montecito Dr., Suite 302,Corona, CA 92879
PHONE (951)817-3680 EMAIL leremiah.acayturri@lenner.com
APPLICANT NAME Lennar Homes of California, Inc.
ADDRESS 980 Montecito Dr.,Suite 302, Corona,CA
PHONE (951)817-3680 EMAIL leremiah.acayturri@lennaccom
CONTRACTOR'S NAME Lennar Homes of California, Inc. OWNER BUILDER? ❑✓ YES❑NO
BUSINESS NAME Lennar Homes of California, Inc.
ADDRESS 980 Montecito Dr, Suite 302,Corona, CA
PHONE (951)817-3680 EMAIL jeremiah.acayturri@lennar.com
CONTRACTOR'S STATE LIC NUMBER 728102 LICENSE CLASSIFICATION A&B
VALUATION $ $6,943.00 SQ FT L SO.FT
APPLICANT'S SIGNATURE DATE 12/15/2015
DEPARTMENT DISTRIBUTION cc coo
CITY OF MENIFEE BUSINESS LICENSE NUMBER
BUILDING PLANNING ENGINEERING FIRE GREEN SMIP
INVOICE (�7., 00 PAIDAMOUNT
AMOUNT v dCASH �CHECKN CREDIT CARD VISA/MC
PLAN CHECK FEES PAID AMOUNT 0 CASH O CHECK# O CREDIT CARD VISA/MC
OWNER BUILDERVERIFIED OYES C NO DL NUMBER NOTARIZED LETTER G YES 0 NO
City of Menifee Building&Safety Department 29714 Haun Rd. Menifee, CA 92586 951-672-6777
www.cityofinenifee.us Inspection Request Line 951-246-6213
SYSTEM INFORMATION BUYER ACKNOWLEDGES THAT THE SOLAR MODULES TO BE INSTALLED,
ITEM OTY MFR. MODEL ON THE ROOF OF THE HOME WILL BE SUBSTANTIALLY IN THE
SYSTEM SIZE 1 2.65 XW LOCATIONS INDICATED BY THE ILLUSTRATION.
MODULE 10 PCS.1 HYUNDAI HiS-S265RG(265W) BUYER: _
INVERTER 10PCS. ENPHASE M215-60-2LL-S22-IG C1T°f � r NI NIFE
ROOF TYPE TILE W/COMPOSITE SHINGLE UNDER ARRAY DATE: BUILDING,{�SUB-ARRAY INFORMATION
J3 AND
ARRAY#I ARRAY#2 ARRAY#3 ryn MOD OTY 10 NA NA BUYER: PPR VA
TILT 23° NA- NA' RAIN
AZIMUTH 140° NA° NA' DATE:
City of Menifee
Building Dept kEV'kRAJED Le
DEC 2 1 2.0
`P ppml,al•)`these I fans sh
awrortal of,any viol Ition of
�Rle
rexuLRtions and ordi iances.
3•-m• ID•-f0• IDuslce until comple ion.
— ——— ---
I
I -
t I
I
I
I
az
a�
HLL
I I
1
SOLADECK WIRE
TRANSITION BOX
(UNDER ARRAY)
_ PV AC DISCONNECT
EXTERIOR-GARAGE
UTILITY METER 8
L—— — ——— MAIN SERVICE PANEL
—— ———— (VERIFIED BY BUILDER)
O
NOTE:DIMENSIONS ARE SHOWN IN PLANE OF ROOF
PLAN 2077 ELEVATION A REVERSE
ORIENTATION 2 1-019 94
ORIGINAL BY: BRI MORRIS DATEA5.11.11
LENNAR:
CAMELLIA AT REVIEWED BY:JIMMY METER DATE:15.11.11
980 O DRIVE,#302
THE LAKES CORONA.NA.CA CA 92879 REV.# BY DATE DESCRIPTION
namast;�
ouv
DWG TITLE: PAGE#: SCALE: SITE LOCATION: 4571 Broadway Street
INDIVIDUAL 29714 ELMSWOOD CIRCLE Boulder,CO 803N
PLOT PLAN I VI6'=1'-0' MENIFEE,CA 303.447.0300
SYSTEM LAYOUT
MODULE SPECS AND CALCULATIONS INVERTER SPECS AND CALCULATIONS
ITEM NOTE/CALC UNIT DETAIL ITEM NOTE 7 CALC UNIT DETAIL
LOCATION MENIFEE,CA INV. MAKE INVERTER SPEC ENPHASE
TEMP,AMBIENT HIGH(TMAX) ASHRAE 2% 'C 37 INV. MODEL INVERTER SPEC M215-60-21JL-S22-IG
TEMP.AMBIENT LOW(THIN) ASHRAE EXTR.MIN 'C -2 INV. MAX POWER.(WAC MAX) INVERTER SPEC WATTS(AC) 225
TEMP,MODULE TEST(TTEST) MODULE SPEC °C 25 INV. INPUT V.(Voc MAX) INVERTER SPEC VOLTS(DD) 48 EPA
TEMP.DELTA LOW(TEELTA) THIN-TTEST °C -27 INV.OUTPUT V.(VAc NON) INVERTER SPEC VOLTS(AO) 240
MOD. MANUFACTURER MODULE SPEC HYUNDAI INV.OUTPUT FREQUENCY INVERTER SPEC HERTZ 60
MOD.PART NUMBER MODULE SPEC HIS-S265RG INV.OUTPUT CURRENT, IAC INVERTER SPEC AMPS(AC) 0.9
MOD.POWER STC(P) MODULE SPEC WATTS(OC) 265 INV.PHASE QUANTITY INVERTER SPEC PHASE I
MOD.POWER PTC MODULE SPEC WATTS(DC) 238 COMPLIANCE INVERTER SPEC ULI741/IEEE1547
MOD.OPERATING VOLTAGE(VMP) MODULE SPEC VOLTS(DC) 31.30 INV.GROUNDING INVERTER SPEC I OLATED
MOD.OPEN CCT. VOLTAGE(VOC) MODULE SPEC VOLTS(DC) 38.10 INV. OTY.MAX/BRANCH CCT. INV.QTY" OTY 10
MOD.COEFF.VOLT/TEMP(COEF) MODULE SPEC V/°C -0.114 BRANCH CCT.OUTPUT,IMAX6D I(IAC•INV.QTYBC) I AMPS(AC) i
19.00
MOD.MAX VOLTAGE(VMAXMOD) (VOC+(TD'COEF)) VOLTS(DC) 41.18 INV.QUANTITY.TOTAL INV.QTVi QTY 10
MOD.OPERATING CURRENT(IMP) MODULE SPEC AMPS(DU 8.50 TOTAL SYSTEM OUTPUT,IMAXTs I(IAC'INV.QTYT) I AMPS(AC) 1 9.00
MOD.SHORT CCT.CURRENT OSC) MODULE SPEC AMPS(DC) 9.00
MOD.MAXIMUM CURRENT(IMAX) Osc•1.25) AMPS(DC) 11.25
MIN. AMPACITY REQ'D,PER NEC (IMAX•1.25) AMPS(Dd 14.06 ^^COn$Ned t0
SERIES FUSE RATING,MAX MODULE SPEC AMPS(DC) IS
ELECTRICAL EQUIPMENT SCHEDULE D,LviSion ofthe
KEY OTY MANUFACTURER MODEL NOTES TRADE s;_(ofap rovedI
1 10 HYUNDAI HIS-S265RG(265W) PV MODULE SOLAR
2 10 ENPHASE M215-60-2LL-S22-IG PVINVERTER SOLAR
3 1 RSTC/SOLADECK 0786-3R5 PV ROOF JUNCTION BOX,NEMA 3R SOLAR
4 1 CUTLER-HAMMER DG221URB PV AC DISCONNECT,NEMA 3R,24OV.30A SOLAR
5 1 ENPHASE ENVOY PV DATA MONITOR,120V SOLAR
6 1 TBD TBD 120V DEDICATED RECEPTACLE FOR ENVOY PV DATA MONITOR SOLAR
7 1 TBD TBD CATS PORT FOR SOLAR PV INTERNET CONNECTION TO HOME NETWORK BOX SOLAR
8 NOTE CUTLER-HAMMER TBD PV BRANCH CIRCUIT BREAKERS:I x 15A-IP(ENVOY) SOLAR
9 NOTE CUTLER-HAMMER TBD PV BREAKER,I x 20A-2P,LOCATE AT OPPOSITE END OF BUS FROM MAIN BREAKER SOLAR
10 I TBD TBD SERVICE PANEL,MIN. 125A BUS BLOB.ELEL.
II TBD TBD UTILITY METER,]PH.120/24OV,200A BLDR,ELEL.
12 1 1 1 TBD I TBD I GROUNDING ELECTRODE UFER BLDR.ELEL.
CONDUCTOR SIZING CALCULATIONS INTERCONNECTION CALCULATIONS
U CONDITION OF USE(COL): (AMPACITY•TEMP.DEBATE'FILL DEBATE)Vs.REQ'0(IMAX) ITEM UNIT PANEL
2)TERMINALS(TERM): AMPACITY AT TERMINALS.Vs.REQ'D.(IMAX- 1.25) PANEL MI CUTLER-HAMMER
KEY SIZE CU/AL INSULATION CALC. AMPACITY W/O TEMP. FILL RESULT REQ'D OCD BUS RATING AMPS 200
TYPE DERATES DERATE DERATE (A) (A) USED(A) MAIN DISCONNECT AMPS 2DO
A #12 CU THWN-2 COU 30 0.76 1 1.0 22.80 9.00 ALLOWED PV PER NEC AMPS 40
TERM 25 1 25 11.25 20 PV OCPD DEVICE USED AMPS 20
B #to CU NM-B COU 40 0.91 11.0 36.40 9.00
TERM 35 35 11.25 20
C #to Cu NM-B COU 40 36.40 9.00
0.91 L0
TERM 35 35 11.25 20
CONDUCTOR SCHEDULE
KEY CONDUCTORS 1 CU/AL 1 TYPE 1 LOCATION TRADE
A 1-#12 ENGAGE CABLE,1-#6G.FREE AIR CU TC-ER ARRAY SOLAR
B 3-#to.I-#10 EGG I CU I NM-B(ROMEX) INTERIOR I SOLAR
C 1 3-#10,1-#10 EGC CU I NM-B(ROMEX) INTERIOR I SOLAR
D I CAT5E.ETHERNET CABLE CU I CAT5E INTERIOR I SOLAR
5 6 II
7 0 • O-
SEE NOTE IS I 10
OISP/w
9 O mug
3
�N
G G
ROOF EXTERIOR-GARAGE
ELECTRICAL DIAGRAM 2.65 xW
LOT#94
LENNAR: ORIGINAL BY: BRI MORRIS I DATE:I5.11.11
CAMELLIA AT 980 MONTECITO DRIVE,#302 REVIEWED BV:JIMMY METER I DATE:15.11.11
THE LAKES CORONA.CA 92879 REV.# BY DATE DESCRIPTION
rV sosAv SOLAR
DWG TITLE: PAGE#: SCALE: SITE LOCATION: 4574 Broadway Street
INDIVIDUAL 29714 ELMSWOOD CIRCLE Boulder,CO 60304
PLOT PLAN 2 NTS MENIFEE,LA 303.447.0300
ELECTRICAL
STRUCTURAL NOTES:
SOLAR CONTRACTOR-
S ALL PV ROOF ATTACHMENTS WILL BE SPACED ALONG MODULE RACKING RAILS AT NOT GREATER THAN 48'O.C.
2)ALL PV ROOF ATTACHMENTS WILL BE STAGGERED BY ROW AMONGST THE ROOF FRAMING MEMBERS.TO MAXIMUM EXTENT POSSIBLE.
3)ROOF PENETRATIONS ASSOCIATED WITH SOLAR RACKING WILL BE SEALED WITH AN APPROVED SEALANT. ( ENT
4)SOLADECK WIRE TRANSITION BOX WILL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS. IT WILL BE FLASHED AND SEALED.
5)PV ARRAY WILL BE A MINIMUM OF 3'ABOVE THE COMPOSITE SHINGLE ROOF SURFACE.
6)THE UNIRAC SOLARMOUNT RACKING SYSTEM AND SOLAR PV ARRAY WILL BE INSTALLED ACCORDING TO THE UNIRAC SOLARMOUNT CODE-COMPLIANT INSTALLATION
MANUAL,VERSION 227.3.PUB 140113-ICC,JANUARY 2014.
7)UNIRAC TOP CLAMPS REQUIRE A ONE INCH W)SPACE BETWEEN PV MODULES.SOLARMOUNT RAILS MUST EXTEND A MINIMUM OF TWO INCHES(2)BEYOND THE EDGE
OF THE PV ARRAY/SUB-ARRAY.
8)UNIRAC SOLARMOUNT REQUIRES THAT A THERMAL EXPANSION GAP BE INSTALLED FOR ANY RAIL LENGTH OF GREATER THAN 40'.
ROOFING CONTRACTOR-
U DISTANCE BETWEEN ARRAY EDGE AND TRANSITION FLASHING(COMPOSITION TO TILE)WILL BE A MINIMUM OF Y.
2)26 GAUGE INTERLOCKING FLASHING'SIDEWALL'TO BE INSTALLED ALONG THE LENGTH OF THE PV ARRAY AT ROOFING MATERIAL TRANSITION. IT SHALL BE
APROVED PRIOR TO PV SYSTEM INSTALLATION.
3)PEEL-N-STICK BASE TO BE INSTALLED ONE FOOT(11 OR MORE BEYOND THE EDGE OF THE COMPOSITION SHINGLE,DOWN TO THE ROOF EAVE. PEEL-N-STICK BASE TO
BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS.
4)AREAS UNDER EACH PV ARRAY SHALL BE ROOFED WITH COMPOSITION SHINGLE.COMPOSITION SHINGLE SHALL RUN FROM ABOVE THE PV ARRAY TO THE ROOF EAVE. B iermit IOI
5)TILE INSTALLED BELOW THE ARRAY TO BE INSTALLED ABOVE THE COMPOSITION ROOF PER ROOFER SPECIFICATIONS.
6)BIRDSTOP WILL BE INSTALLED AT THE UPPERMOST TRANSITION FROM TILE TO COMPOSITION SHINGLE. BIRDSTOP TO BE SPECIFIED BY ROOFER PRIOR TO ri1/state 01
INSTALLATION.
s nustbek
ELECTRICAL NOTES:
GENERAL-
D ALL PV EQUIPMENT WILL BE TESTED AND LISTED FOR ITS USE BY A NATIONALLY RECOGNIZED TESTING LABORATORY(NRTL).
2)THE GROUNDING OF THE PHOTOVOLTAIC SYSTEM SHALL COMPLY WITH THE APPLICABLE VERSION OF THE NEC/CEC.
3)ALL GROUNDING ELECTRODE CONDUCTORS WILL BE INSTALLED IN A CONTINUOUS LENGTH EXCEPT WHERE SPLICED BY AN IRREVERSIBLE CONNECTOR OR EXOTHERMIC
WELD.
4)NON-CURRENT CARRYING METAL PARTS SHALL BE CHECKED FOR PROPER GROUNDING,NOTING THAT TERMINAL LUGS BOLTED ON AN ENCLOSURE'S FINISHED SURFACE
MAY BE ELECTRICALLY INSULATED BECAUSE OF PAINT/FINISH. PAINT/FINISH AT POINT OF CONTACT SHALL BE PROPERLY REMOVED.
5)ROOF PENETRATIONS WILL BE COMPLETED AND SEALED PER APPLICABLE CODE.
6)ALL CONDUCTORS WILL HAVE A 90-C RATING TO ENSURE CODE COMPLIANCE.
SOLAR CONTRACTOR-
7)MODULE CERTIFICATIONS WILL INCLUDE UL1703,IEC61646,IEC61730.
8)CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS.
9)RACEWAY POINT OF PENETRATION FROM EXTERIOR TO INTERIOR WILL BE SEALED TO PREVENT INGRESS OF WATER AND INSECTS,
10)DC WIRING IS LIMITED TO PV ARRAY FOOTPRINT W/ENPHASE MICRO-INVERTER SYSTEM.
11)MODULE AND ENPHASE WIRING SHALL BE LOCATED AND SECURED UNDER THE ARRAY USING SUITABLE WIRING CLIPS.WIRING SHALL NOT MAKE CONTACT WITH THE
ROOF SURFACE AND SHALL BE MANAGED IN A WORKMAN-LIKE MANNER.
12)EQUIPMENT GROUNDING CONDUCTORS WILL BE SIZED IN ACCORDANCE WITH NEC TABLE 250.122.
13)CONDUCTOR TERMINATIONS WILL BE TORQUED PER DEVICE LISTING.OR MANUFACTURER'S RECOMMENDATIONS.
14)A PV AGGREGATION PANEL(SUB PANEL)WILL NOT BE INCLUDED FOR SYSTEMS WITH ONE BRANCH CIRCUIT.
15)A DEDICATED 120V BRANCH CIRCUIT IS REQUIRED IN MASTER CLOSET(OR EQUIVALENT)FOR ENPHASE ENVOY MONITOR.
SIGNAGE-
16)PV SYSTEMS SHALL BE CLEARLY MARKED IN ACCORDANCE WITH NEC ARTICLE 690 AND OTHER APPLICABLE STATE AND LOCAL CODES.
17)ALL SAFETY MARKING/PLACARDS SHALL BE PERMANENTLY ATTACHED BY ADHESIVE OR OTHER MECHANICAL MEANS.
18)MARKING/PLACARDS WILL BE METAL OR PLASTIC WITH ENGRAVED OR MACHINE PRINTED LETTERING.BACKGROUND WILL BE RED WITH WHITE CAPITAL LETTERING OF
MINIMUM HEIGHT�.
19)ALL WIRING/RACEWAYS/JUNCTION BOXES WILL BE MARKED'PHOTOVOLTAIC POWER SOURCE:OR EQUIVALENT:WIRING/RACEWAYS SHALL BE MARKED EVERY 10'.
BUILDER ELECTRICAL AND SOLAR CONTRACTORS-
20)INSTALLATION SHALL BE COMPLETED IN A NEAT AND WORKMAN-LIKE MANNER.
21)SPACE REQUIREMENTS FOR ALL ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110.26.
LENNAR: ORIGINAL BY: BRI MORRIS DATE:15.11.11
CAMELLIA AT 980 MONTELITO DRIVE,#302 REVIEWED BV:JIMMY METER DATE:15.11.11
THE LAKES CORONA,CA 92879 REV.# BY DATE I DESCRIPTION 0
namaste
f DlA9
DWG TITLE: PAGE#: 1 SCALE: SITE LOCATION:
INDIVIDUAL 4577 Broatlway Btr 4
PLOT PLAN 3 NTS MENI ELMSWOOD CIRCLE BaW3, C080304
NOTES MENIFEE,CA 303.d4].0300
CAUTION:
POWER TO THIS BUILDING IS SUPPLIED BY THE
UTILITY AND A SOLAR PV SYSTEM. DISCONNECTS
ARE LOCATED AS SHOWN.
ATE
an
4
on the
it
soLmEcx wIRE
TRx1LTIQ4 BOx
(1POER avRnn
PV Rc DSXONl T
E%iFAIOR-GCRl6E
UT11TY MEiEN 6
MdIN SERVICE PoNEL
(V FIEE RY BYL.R)
IL=11
SERVICE BY QUALIFIED PERSONNEL ONLY
CONTACT: SUNSTREET ENERGY GROUP
1-877-SLR-POWR
PV POWER SOURCE - AC SPECS
AC OPERATING VOLTAGE: 240 V
AC OPERATING CURRENT: 9.0 A
NOTE: SEE MASTER SET FOR ADDITIONAL PLACARD INFORMATION
ORIGINAL BY: BRI MORRIS DATE:I5.11.11
CAMELLIA AT LENNAR:
9B0 MONTECITO DRIVE,#302 REVIEWED BY:JIMMY METER DATE:I5.II.11
THE LAKES CORONA,CA 92879 REV.# BY DATE DESCRIPTION •�
namast6
SOLAR
DWG TITLE: r4NTS
CALE: SITE LOCATION: 4571 Broadway Street
INDIVIDUAL 29714 ELMSWOOD CIRCLE Boulder,CO 80304
PLOT PLAN
PLACARDS MENIFEE.CA 303.447.0300