PMT15-03899 City of Menifee Permit No.: PMT15-03899
29714 HAUN RD.
�;1kCCEL/> MENIFEE,CA 92586 Type: Residential Electrical
0.1111"""" MENIFEE Date Issued: 12/23/2015
PERMIT
Site Address: 29690 ELMSWOOD CIR, MENIFEE, CA Parcel Number:
92584 Construction Cost: $6,943.00
Existing Use: Proposed Use:
Description of SOLAR TR 304223 CAMELLIA
Work: 10 MODULES 2.65KW
LOT 92
Owner Contractor
LENNAR HOMES OF CA LENNAR HOMES OF CALIFORNIA INC
980 MONTECITO DR#302 25 ENTERPRISE
CORONA, CA 92879 ALISO VIEJO, CA 92656
Applicant Phone: 9493498269
JEREMIAH ACAYTURRI License Number: 728102
LENNAR HOMES OF CALIFORNIA INC
25 ENTERPRISE
ALISO VIEJO, CA 92656
Fee Description Qtv Amount fbl
Solar, Residential or Small Commercial 1 252.00
Building Permit Issuance 1 27.00
GREEN FEE 1 1.00
SMIP RESIDENTIAL 1 1.00
General Plan Maintenance Fee-Electrical 1 12.60
$293.60
The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and
specifications or from preventing builiding operations being carried on thereunder when in violation of the Building Code or of any other
ordinance of City of Marilee.Except as otherwise stated,a permit for construction under which no work is commenced within six
months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be
forfeited.
AA_Bldg_Permfi_Template.rpt Page 1 of 1
BUILDING & SAFETY PERMIT/PLAN CHECK APPLICATION
Menifee
M r �2
DATE 12/15/2015 PERMIT/PLAN CHECK NUMBER '5 —G `Q
TYPE: ❑COMMERCIAL ❑✓ RESIDENTIAL ❑MULTI-FAMILY ❑MOBILE HOME ❑POOL/SPA []SIGN
SUBTYPE: ❑✓ ADDITION ❑ALTERATION ❑DEMOLITION ❑ELECTRICAL ❑MECHANICAL
❑NEW ❑PLUMBING FIRE-ROOF-NUMBEROFSQUARES
DESCRIPTION OF WORK Solar Permit-Plan 2077-2.65 kW/10 PCS
Master Solar Permit No. PMT14-02630
PROJECTADDRESS 29690 Elmswood, Menifee, CA 92584
ASSESSOR'S PARCEL NUMBER LOT 92 TRACT 30422-3
PROPERTY OWNER'S NAME Lennar Homes of California, Inc.
ADDRESS 980 Montecito Dr.,Suite 302, Corona, CA 92879
PHONE (951)817-3680 EMAIL leremiah.acayturri@lennar.com
APPLICANT NAME Lennar Homes of California, Inc.
ADDRESS 980 Montecito Dr.,Suite 302, Corona,CA
PHONE (951)817-3680 EMAIL leremiah.acayturri@lennar.com
CONTRACTOR'S NAME Lennar Homes of California, Inc. OWNER BUILDER? ❑✓ YES❑NO
BUSINESS NAME Lennar Homes of California, Inc.
ADDRESS 980 Montecito Dr.,Suite 302, Corona,CA
PHONE (951)817-3680 EMAIL jeremiah.acayturri@lennar.com
CONTRACTOR'S STATE LIC NUMBER 728102 LICENSE CLASSIFICATION A&B
VALUATION$ $6,943.00 SO FT
APPLICANT'S SIGNATURE DATE 12/15/2015
CITYSTAFF USE ONLY
DEPARTMENT DISTRIBUTION CITY OF MENIFEE BUSINESS LICENSE NUMBER
BUILDING PLANNING ENGINEERING FIRE GREEN SMIP
INVOICE �/� (pD PAIDAMOUNT
AMOUNT �') 0CASH OCHECKN 0CREDITCARD VISA/MC
PLAN CHECK FEES PAIDAMOUNT GCASH OCHECK4 OCREDITCARD VISA/MC
OWNER BUILDER VERIFIED 0 YES O NO DL NUMBER NOTARIZED LETTER 0 YES 0 NO
City of Menifee Building&Safety Department 29714 Haun Rd. Menifee, CA 92586 951-672-6777
www.cityofinenifee.us Inspection Request Line 951-246-6213
SYSTEM INFORMATION BUYER ACKNOWLEDGES THAT THE SOLAR MODULES TO BE INSTALLED
ITEM OTY MFR. MODEL ON THE ROOF OF THE HOME WILL BE SUBSTANTIALLY IN THE
SYSTEM SIZE 2.AS KW I I LOCATIONS INDICATED BY THE ILLUSTRATION.
MODULE 10PCS. HYUNDAI HIS-S265RG(265W) 1-1 ) Y OF MEI
BUYER:
INVERTER IO PCS. ENPHASE I M215-60-2LL-S22-IG
ROOF TYPE I TILE W/COMPOSITE SHINGLE UNDER ARRAY DATE: W I'I D1 G AI
SUB-ARRAY INFORMATION ARRAY#I 1 ARRAY#2 ARRAY#3 PLA N I A PRC
MOD OTY 10 NA NA BUYER:
TILT 23° 1 NA' I NA'
AZIMUTH 1 I80' 1 NA" I NA• DATE:
City of Menifee
Building Dept
'"oo 04 of tf ese pla
DEC 2 1 2015 ay;Tuval of,an violat
reulations anc ordina
Received jobsite until coi ipletio
r
i
SADECK WIRE
TRANSITION BOX
(UNDER ARRAY)
S PV AC DISCONNECT
EXTERIOR-GARAGE
I UTILITY METER 6
—J L_—_ MAIN SERVICE PANEL
L__ _J (VERIFIED BY BUILDER)
19'-6-ARRAY
IL'-P 219*- FLASHING
NOTE:DIMENSIONS ARE SHOWN IN PLANE OF ROOF N
PLAN 2077 ELEVATION B REVERSE
ORIENTATION 1 LOT#92
LENNAR: ORIGINAL BY: BRI MORRIS DATE:15:11.11
CAMELLIA AT
980 MONTELITO DRIVE,#302 REVIEWED BY:JIMMY METER DATE:15.11.11
THE LAKES CORONA,CA 92879 REV.# BY DATE DESCRIPTION
�Rmarnast;6
aoaee
DWG TITLE: PAGE#: SCALE: SITE LOCATION:
INDIVIDUAL 45/1 ld z,
CO 3Street
PLOT PLAN 1 1/16'=1'-0° MENIF ELM$WDDD CIRCLE Bo3D3. C0303O9
SYSTEM LAYOUT MENIFEE.CA 3D3.497.0300
MODULE SPECS AND CALCULATIONS INVERTER SPECS AND CALCULATIONS
ITEM NOTE/CALC UNIT DETAIL ITEM NOTE/CALC UNIT DETAIL
LOCATION MENIFEE.CA INV.MAKE INVERTER SPEC ENPHASE
TEMP,AMBIENT HIGH(THAR) ASHRAE 2% °C 37 INV.MODEL INVERTER SPEC 11215-60-21-L-S22-IG
TEMP,AMBIENT LOW(THIN) ASHRAE EXTR.MIN °C -2 INV.MAX POWER,(WAc MAX) INVERTER SPEC WATTS(An) 225 DtL TEMP,MODULE TEST(TTEST) MODULE SPEC °C 25 INV. INPUT V.(Voc MAX) INVERTER SPEC VOLTS(oc) 48
TEMP,DELTA LOW(TOELTA) THIN-TTEST •C -27 INV.OUTPUT V,(Vac NOM) INVERTER SPEC VOLTS(AC) 240
MOD.MANUFACTURER MODULE SPEC HYUNDAI INV.OUTPUT FREQUENCY INVERTER SPEC HERTZ 60
MOD.PART NUMBER MODULE SPEC HIS-S265RG INV.OUTPUT CURRENT,IAc INVERTER SPEC AMPS(AC) 0.9
MOD.POWER STC(P) MODULE SPEC WATTS(00 265 INV. PHASE QUANTITY INVERTER SPEC PHASE 1
MOD.POWER PTC MODULE SPEC WATTS(00 23B COMPLIANCE INVERTER SPEC ULl74l/jWl5idF
MOD.OPERATING VOLTAGE(VMP) MODULE SPEC VOLTS(oc) 3L30 INV. GROUNDING INVERTER SPEC ISOLATE
MOD.OPEN CCT.VOLTAGE Nod MODULE SPEC VOLTS(DO 3B.10 INV. OTY.MAX/BRANCtL
CCT. INV.QTYBc OTY 10
MOD. COEFF.VOLTITEMP(COEF) MODULE SPEC V/°C -0.114 BRANCH CCT.OUTPUT,M C (pC°INV.GTYBC) AMPS(AC) 9.00
MOD. MAX VOLTAGE(VMAXMOB) (VOC♦(TO°COEF)) VOLTS(oc) 41.18 INV. QUANTITY, TOTAL I INV.QTYT OTY 10
MOD. OPERATING CURRENT(IMP) MODULE SPEC AMPS DOC) 8.50 TOTAL SYSTEM OUTPUT.IMAXTs I (IAc°INV.GTYT) AMPS(AU 9.00
MOD. SHORT CCT. CURRENT 0sc) MODULE SPEC AMPS(DO 9.00
MOD. MAXIMUM CURRENT OMAA) (ISC° 1.25) AMPS(oc) 11.25 ;all not be OnstrU2
MIN.AMPACITY REQ'D,PER NEC (IMAX-1.25) AMPS(oc) 14.06
SERIES FUSE RATING.MAX MODULE SPEC AMPS(oc) 1 15 )f any provi ions of
ELECTRICAL EQUIPMENT SCHEDULE ;. This seta appro)
KEY GTY MANUFACTURER MODEL NOTES TRADE
1 10 HYUNDAI HIS-S265RG(265W) PV MODULE SOLAR
2 10 ENPHASE M215-60-ZLL-S22-IG PVINVERTER SOLAR
3 1 RSTC/SOLADECK 0786-3R5 PV ROOF JUNCTION BOX,NEMA 3R SOLAR
4 1 CUTLER-HAMMER DG221URB PV AC DISCONNECT,NEMA 3R,240V.30A SOLAR
5 1 ENPHASE ENVOY PV DATA MONITOR,120V SOLAR
6 1 TBD TBD 120V DEDICATED RECEPTACLE FOR ENVOY PV DATA MONITOR SOLAR
7 1 TBD TBD CATS PORT FOR SOLAR PV INTERNET CONNECTION TO HOME NETWORK BOX SOLAR
B NOTE CUTLER-HAMMER TBD PV BRANCH CIRCUIT BREAKERS; I X 15A-IP(ENVOY) SOLAR
9 NOTE CUTLER-HAMMER TBO PV BREAKER, I x 20A-2P,LOCATE AT OPPOSITE END OF BUS FROM MAIN BREAKER SOLAR
10 TO TBD SERVICE PANEL.MIN. 125A BUS BLDR.EL EC.
11 TBD TBD UTILITY METER, IPH, 120/240V,200A BLDR.ELEC.
12 1 1 1 TBD I TBD I GROUNDING ELECTRODE UFER I BLDR.ELEC.
CONDUCTOR SIZING CALCULATIONS INTERCONNECTION CALCULATIONS
D:CONDITION OF USE(COU): (AMPACITY°TEMP.DERATE°FILL DERATE)Vs.REO'D(IMAx) ITEM UNIT PANEL
2)TERMINALS(TERM): AMPACITY AT TERMINALS.V5.REQ'D,(IMA%° 1.25) PANEL MFR. CUTLER-HAMMER
KEY SIZE CU/AL INSULATION CALC. AMPACITYW/D TEMP. FILL RESULT REO'D OCD BUS RATING AMPS 200
TYPE DEBATES DEBATE DERATE (A) (A) USED(A) MAIN DISCONNECT AMPS 200
A #12 CU THWN-2 COU 30 0.76 1 1.0 22.60 9.00 ALLOWED PV PER NEC AMPS 40
TERM 25 1 25 11.25 20 PV OCPD DEVICE USED AMPS 20
B #to CU NM-B COU 40 0.91 1.0 36.40 9.00
TERM 35 35 11.25 20
C #10 LU NM-B COU 40 0.91 1.0 3&40 9.00
31:04-cu
TERM 35 35 11.25 1 20
CONDUCTOR SCHEDULE
KEY CONDUCTORS 1 CU/AL 1 TYPE 1 LOCATION TRADE
A I-#12 ENGAGE CABLE, -#6G,FREE AIR CU TC-ER ARRAY SOLAR
8 3-#10.1-#10 EGG I CU NM-B(ROMEX) I INTERIOR I SOLAR 5 6 11
C 3-#10.1-#10 EGG CU NM-B(ROMEX) INTERIOR SOLAR
D CATSE,ETHERNET CABLE I CU I CATSE I INTERIOR I SOLAR OO • o 0
M —
SEE NOTE 15 I 10
O 8
4
ISA/IP
o ��N
G G G�
A B C — 12
ROOF E%TERIOR-GARAGE
ELECTRICAL DIAGRAM 2.65XW
LOT#92
ORIGINAL BY: BRI MORRIS DATE:1 .11.11
CAMELLIA AT LENNAR:
980 MONTECITO DRIVE.#302 REVIEWED BY:JIMMY METER I DATE:15.11.11
THE LAKES CORONA.CA 92879 REV.# BY DATE IDESCRIPTION
Onlamast;d
SOLAR
DWG TITLE: PAGE#: SCALE: SITE LOCATION: 4571 Bmdway Street
INDIVIDUAL Z9690 ELMSWOOD CIRCLE Boulder,CO 80304
PLOT PLAN 2 NITS MENIFEE,CA
303.447.0300
ELECTRICAL
STRUCTURAL NOTES:
SOLAR CONTRACTOR-
S ALL PV ROOF ATTACHMENTS WILL BE SPACED ALONG MODULE RACKING RAILS AT NOT GREATER THAN 48'O.C.
2)ALL PV ROOF ATTACHMENTS WILL BE STAGGERED BY ROW AMONGST THE ROOF FRAMING MEMBERS,TO MAXIMUM EXTENT POSSIBLE.
3)ROOF PENETRATIONS ASSOCIATED WITH SOLAR RACKING WILL BE SEALED WITH AN APPROVED SEALANT. TIME
SOLADECK WIRE TRANSITION BOX WILL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS. IT WILL BE FLASHED AND SEALED.
5)PV ARRAY WILL BE A MINIMUM OF 3'ABOVE THE COMPOSITE SHINGLE ROOF SURFACE.
6)THE UNIRAC SOLARMOUNT RACKING SYSTEM AND SOLAR PV ARRAY WILL BE INSTALLED ACCORDING TO THE UNIRAC SOLARMOUNT CODE-COMPLIANT INSTALLATION
MANUAL,VERSION 227.3.PUB 140113-ICC,JANUARY 2014.
7)UNIRAC TOP CLAMPS REQUIRE A ONE INCH 01 SPACE BETWEEN PV MODULES.SOLARMOUNT RAILS MUST EXTEND A MINIMUM OF TWO INCHES(2')BEYOND THE EDGE
OF THE PV ARRAY/SUB-ARRAY.
8)UNIRAC SOLARMOUNT REQUIRES THAT A THERMAL EXPANSION GAP BE INSTALLED FOR ANY RAIL LENGTH OF GREATER THAN 40'.
ROOFING CONTRACTOR-
D DISTANCE BETWEEN ARRAY EDGE AND TRANSITION FLASHING(COMPOSITION TO TILE)WILL BE A MINIMUM OF 3'.
2)26 GAUGE INTERLOCKING FLASHING'SIDEWALL'TO BE INSTALLED ALONG THE LENGTH OF THE PV ARRAY AT ROOFING MATERIAL TRANSITION. IT SHALL BE
APROVED PRIOR TO PV SYSTEM INSTALLATION.
3)PEEL-N-STICK BASE TO BE INSTALLED ONE FOOT(I')OR MORE BEYOND THE EDGE OF THE COMPOSITION SHINGLE.DOWN TO THE ROOF EAVE.PEEL-N-STICK BASE TO
BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS.
4)AREAS UNDER EACH PV ARRAY SHALL BE ROOFED WITH COMPOSITION SHINGLE.COMPOSITION SHINGLE SHALL RUN FROM ABOVE THE PV ARRAY TO THE ROOF EAVE. be a permh
5)TILE INSTALLED BELOW THE ARRAY TO BE INSTALLED ABOVE THE COMPOSITION ROOF PER ROOFER SPECIFICATIONS.
6)BIRDSTOP WILL BE INSTALLED AT THE UPPERMOST TRANSITION FROM TILE TO COMPOSITION SHINGLE.BIRDSTOP TO BE SPECIFIED BY ROOFER PRIOR TO led nl,state
INSTALLATION. p:ai s must 6
ELECTRICAL NOTES:
GENERAL-
U ALL PV EQUIPMENT WILL BE TESTED AND LISTED FOR ITS USE BY A NATIONALLY RECOGNIZED TESTING LABORATORY(NRTI).
2)THE GROUNDING OF THE PHOTOVOLTAIC SYSTEM SHALL COMPLY WITH THE APPLICABLE VERSION OF THE NEC/CEC.
3)ALL GROUNDING ELECTRODE CONDUCTORS WILL BE INSTALLED IN A CONTINUOUS LENGTH EXCEPT WHERE SPLICED BY AN IRREVERSIBLE CONNECTOR OR EXOTHERMIC
WELD.
4)NON-CURRENT CARRYING METAL PARTS SHALL BE CHECKED FOR PROPER GROUNDING.NOTING THAT TERMINAL LUGS BOLTED ON AN ENCLOSURE'S FINISHED SURFACE
MAY BE ELECTRICALLY INSULATED BECAUSE OF PAINT/FINISH. PAINT/FINISH AT POINT OF CONTACT SHALL BE PROPERLY REMOVED.
5)ROOF PENETRATIONS WILL BE COMPLETED AND SEALED PER APPLICABLE CODE.
6)ALL CONDUCTORS WILL HAVE A 90-C RATING TO ENSURE CODE COMPLIANCE.
SOLAR CONTRACTOR-
7)MODULE CERTIFICATIONS WILL INCLUDE 1.L1703.IEC61646,IEC61730.
8)CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS.
9)RACEWAY POINT OF PENETRATION FROM EXTERIOR TO INTERIOR WILL BE SEALED TO PREVENT INGRESS OF WATER AND INSECTS.
10)DC WIRING IS LIMITED TO PV ARRAY FOOTPRINT W/ENPHASE MICRO-INVERTER SYSTEM.
11)MODULE AND ENPHASE WIRING SMALL BE LOCATED AND SECURED UNDER THE ARRAY USING SUITABLE WIRING CLIPS.WIRING SHALL NOT MAKE CONTACT WITH THE
ROOF SURFACE AND SHALL BE MANAGED IN A WORKMAN-LIKE MANNER.
12)EQUIPMENT GROUNDING CONDUCTORS WILL BE SIZED IN ACCORDANCE WITH NEC TABLE 250.122.
13)CONDUCTORS TERMINATIONS WILL BE TORQUED PER DEVICE LISTING.OR MANUFACTURER'S RECOMMENDATIONS.
14)A PV AGGREGATION PANEL(SUB PANEL)WILL NOT BE INCLUDED FOR SYSTEMS WITH ONE BRANCH CIRCUIT.
15)A DEDICATED 120V BRANCH CIRCUIT IS REQUIRED IN MASTER CLOSET(OR EQUIVALENT)FOR ENPHASE ENVOY MONITOR.
SIGNAGE-
16)PV SYSTEMS SHALL BE CLEARLY MARKED IN ACCORDANCE WITH NEC ARTICLE 690 AND OTHER APPLICABLE STATE AND LOCAL CODES.
17)ALL SAFETY MARKING/PLACARDS SHALL BE PERMANENTLY ATTACHED BY ADHESIVE OR OTHER MECHANICAL MEANS.
18)MARKING/PLACARDS WILL BE METAL OR PLASTIC WITH ENGRAVED OR MACHINE PRINTED LETTERING. BACKGROUND WILL BE RED WITH WHITE CAPITAL LETTERING OF
MINIMUM HEIGHT t.
19)ALL WIRING/RACEWAYS/JUNCTION BOXES WILL BE MARKED'PHOTOVOLTAIC POWER SOURCE,'OR EQUIVALENT:WIRING/RACEWAYS SHALL BE MARKED EVERY 10'.
BUILDER ELECTRICAL AND SOLAR CONTRACTORS-
20)INSTALLATION SHALL BE COMPLETED IN A NEAT AND WORKMAN-LIKE MANNER.
21)SPACE REOUIREMENTS FOR ALL ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110.26.
LENNAR:. ORIGINAL BY: BRI MORRIS DATE:I5.11.11
CAMELLIA AT 980 MONTECITO DRIVE.4302 REVIEWED BY:JIMMY METER DATE:15.11-11
THE LAKES CORONA,CA 92a79 REV.# BY DATE DESCRIPTION •,
namast6
DWG TITLE: PAGE#: I SCALE: SITE LOCATION: 4571 Broadway Slreat
INDIVIDUAL 29690 ELMSWOOD CIRCLE Boulder,CO 60304
PLOT PLAN 3 NTS MENIFEE,CA
NOTES 303.447.0300
CAUTION:
POWER TO THIS BUILDING IS SUPPLIED BY THE
UTILITY AND A SOLAR PV SYSTEM. DISCONNECTS
ARE LOCATED AS SHOWN.
V
DATE
Crap
:ity
pr 0 the
BIXAOECR WIPE
1RAH TIMNo
(IR0.A eR W
01
Pv eC oISCWxEci
EFRPIgi-GWALE
IIrILITY IEIER E
.W SERVICE PAWL
DeffiFEDBYSuILBEPI
SERVICE BY QUALIFIED PERSONNEL ONLY
CONTACT: SUNSTREET ENERGY GROUP
1-877-SLR-POWR
PV POWER SOURCE - AC SPECS
AC OPERATING VOLTAGE: 240 V
AC OPERATING CURRENT: 9.0 A
NOTE: SEE MASTER SET FOR ADDITIONAL PLACARD INFORMATION
: ORIGINAL BY: BRI MORRIS DATE:15.11.11
CAMELLIA AT LENNAR
980 MONTECITO DRIVE.#302 REVIEWED BY:JIMMY METER DATE:15.11.11
THE LAKES CORONA.CA 92879 REV.# BY DATE DESCRIPTION
Vnamasbd
FCL.eB
DWG TITLE: PAGE#: SCALE: SITE LOCATION: 4571 Broadway Street
INDIVIDUAL 29690 ELMSWOOD CIRCLE Boulder,CO 80304
PLOT PLAN A NTS M .
PLACARDS 303.44].0300
ENIFEE CA