Loading...
PMT15-03893 City of Menifee Permit No.: PMT15-03893 29714 HAUN RD. �CCEL/k� MENIFEE, CA 92586 Type: Residential Electrical MENIFEE Date Issued: 1 212 312 01 5 PERMIT Site Address: 29712 GLENNEYRE WAY, MENIFEE,CA Parcel Number: 92584 Construction Cost: $6,943.00 Existing Use: Proposed Use: Description of SOLAR TR 30422-3 CAMELLIA Work: 10 MODULES 2.65KW LOT 87 Owner Contractor LENNAR HOMES OF CA LENNAR HOMES OF CALIFORNIA INC 980 MONTECITO DR#302 25 ENTERPRISE CORONA, CA 92879 ALISO VIEJO, CA 92656 Applicant Phone:9493498269 JEREMIAH ACAYTURRI License Number:728102 LENNAR HOMES OF CALIFORNIA INC 25 ENTERPRISE ALISO VIEJO, CA 92656 Fee Description -Otz Amount f51 Solar, Residential or Small Commercial 1 252.00 Building Permit Issuance 1 27.00 GREEN FEE 1 1.00 SMIP RESIDENTIAL 1 1.00 General Plan Maintenance Fee-Electrical 1 12.60 $293.60 The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and specifications or from preventing builiding operations being carried on thereunder when in violation of the Building Code or of any other ordinance of City of Menifee.Except as otherwise stated,a permit for construction under which no work is commenced within six months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be forfeited. AA_Bidg Perrnit_Template.rpt Page 1 of 1 PERMIT/PLANBUILDING & SAFETY APPLICATION Menifee DATE 1 211 5/20 1 5 PERMIT/PLAN CHECK NUMBER Nt'[�5 038G 3 TYPE: ❑COMMERCIAL ❑✓ RESIDENTIAL ❑MULTI-FAMILY ❑MOBILEHOME ❑POOL/SPA ❑SIGN SUBTYPE: ❑✓ ADDITION ❑ALTERATION ❑DEMOLITION [-]ELECTRICAL [-]MECHANICAL [-]NEW ❑PLUMBING [:IRE-ROOF-NUMBEROFSQUARES DESCRIPTION OF WORK Solar Permit-Plan 2077-2.65 kW/10 PCS Master Solar Permit No. PMT14-02630 PROJECT ADDRESS 29712 Glenneyre Way, Menifee,CA 92584 ASSESSOR'S PARCEL NUMBER LOT 87 TRACT 30422-3 PROPERTY OWNER'S NAME Lennar Homes of California, Inc. ADDRESS 980 Montecito Dr., Suite 302, Corona,CA 92879 PHONE (951)817-3680 EMAIL jeremiah.acayturri@lennar.com APPLICANT NAME Lennar Homes of California, Inc. ADDRESS 980 Montecito Dr.,Suite 302, Corona,CA PHONE (951)817-3680 EMAIL jeremiah.acayturri@lennar.com CONTRACTOR'S NAME Lennar Homes of California, Inc. OWNER BUILDER? ❑✓ YES❑NO BUSINESS NAME Lennar Homes of California, Inc. ADDRESS 980 Montecito Dr.,Suite 302, Corona, CA PHONE (951)817-3680 EMAIL jeremiah.acayturri@lennar.com CONTRACTOR'S STATE LIC NUMBER 728102 LICENSE CLASSIFICATION A&B VALUATION$ $6,943.00 L SQ FT APPLICANT'S SIGNATURE DATE 1 211 5/20 1 5 CITY STAFF USE ONLY DEPARTMENT DISTRIBUTION CITY OF MENIFEE BUSINESS LICENSE NUMBER BUILDING PLANNING ENGINEERING FIRE GREEN I SMIP INVOICE O PAID AMOUNT AMOUNT � 3' O CASH O CHECK# O CREDITCARD VISA/MC PLAN CHECK FEES PAID AMOUNT 0 CASH O CHECK# O CREDIT CARD VISA/MC OWNER BUILDER VERIFIED O YES O NO DL NUMBER NOTARIZED LETTER 0 YES 0 NO City of Menifee Building&Safety Department 29714 Haun Rd. Menifee, CA 92586 951-672-6777 www.cityofinenifee.us Inspection Request Line 951-246-6213 SYSTEM INFORMATION BUYER ACKNOWLEDGES THAT THE SOLAR MODULES TO BE INSTALLED ITEM 1 OTY MFR. 1 MODEL ON THE ROOF OF THE HOME WILL BE SUBSTANTIALLY IN THE SYSTEM SIZE 2.65 KW LOCATIONS INDICATED BY THE ILLUSTRATION. MODULE 1 10 PCS.1 HYUNDAI I HIS-5265RG(265W) BUYER: INVERTER 1 10 PCS.1 ENPHASE I M215-60-2LL-S22-IG ROOF TYPE I TILE W/COMPOSITE SHINGLE UNDER ARRAY DATE: SUB-ARRAY INFORMATION ARRAY#1 ARRAY#2 ARRAY#3 MOD OTY 10 NA NA BUYER: CITY F M TILT 23' NA' NA' GATE: AZIMUTH 204' NA' NA' NG City of Menifee PLAN PPI Building Dept DEC 2 1 2915 REVIEWED Received eceived `Approval of these approval of,any vio I I regulations ndord I jobsite until omple I I I I I I I I I I SOLADECK WIRE TRANSITION BOX (UNDER ARRAY) PV AC DISCONNECT EXTERIOR-GARAGE I UTILITY METER 8 MAIN SERVICE PANEL (VERIFIED BY BUILDER) L———— L 19'-6'ARRAY 20'-4'FLASHING NOTE:DIMENSIONS ARE SHOWN IN PLANE OF ROOF PLAN ELEVATION C ORIENTATION ON I LO #B ORIGINAL BY: BRI MORRIS DATE:IS.IO.OS CAMELLIA AT LENNAR: 980 MONTELITO DRIVE,#302 REVIEWED BY:JIMMY METER I DATE:15.10.05 THE LAKES CORONA,CA 92879 REV.# BY DATE DESCRIPTION �Pnamast;6 sores DWG TITLE: PAGE#: SCALE: SITE LOCATION: 4571 Broadway Street INDIVIDUAL 29712 GLENNEYRE WAY SmIder,CO 80304 PLOT PLAN 1 1/16'=V-O' MENIFEE.CA 3W.M7.I 300 SYSTEM LAYOUT MODULE SPECS AND CALCULATIONS INVERTER SPECS AND CALCULATIONS ITEM NOTE/CALC UNIT DETAIL ITEM NOTE/CALC UNIT DETAIL LOCATION MENIFEE,CA INV.MAKE INVERTER SPEC ENPHASE TEMP,AMBIENT HIGH(THAX) ASHRAE 2% °C 37 INV.MODEL INVERTER SPEC M215-60-2LL-S22-IG TEMP,AMBIENT LOW(THIN) ASHRAE EXTR.MIN •C -2 INV.MAX POWER.(WAC MAX) INVERTER SPEC WATTS(AC) Z25 TEMP,MODULE TEST(TTEST) MODULE SPEC °C 25 INV. INPUT V.(VDC MAX) INVERTER SPEC VOLTS(OC) 48 TEMP,DELTA LOW(TOELTA) THIN-TTEST °C -27 INV.OUTPUT V.(VAC NOM) INVERTER SPEC VOLTS(Aa) 240 MOD.MANUFACTURER MODULE SPEC HYUNDAI INV.OUTPUT FREQUENCY INVERTER SPEC HERTZ 60 MOD,PART NUMBER MODULE SPEC HIS-S265RG INV.OUTPUT CURRENT.IAC INVERTER SPEC AMPS(AC) 0.9 MOD.POWER STC(P) MODULE SPEC WATTS(DO) 265 INV.PHASE QUANTITY INVERTER SPEC PHASE I MOD.POWER PTC MODULE SPEC WATTS(DC) 238 COMPLIANCE INVERTER SPEC UL1741/IEE 7 MOD.OPERATING VOLTAGE(VMP) MODULE SPEC VOLTS(oc) 31.30 INV.GROUNDING INVERTER SPEC ISOLATED MOD.OPEN CCT.VOLTAGE(VOC) MODULE SPEC VOLTS(DO 38.10 INV.CITY,MAX/BRANCH CCT. INV.QTYBci GTY I I0ImFEr MOD.COEFF. VOLT/TEMP(COEF) MODULE SPEC WPC -0.114 BRANCH CCT.OUTPUT. IMAXBC (IAC°INV.GTYBC) I AMPS(AC) 119.00 MOD.MAX VOLTAGE(VMAXMOO) (Vac•(TD°COEF)) VOLTS(DC) 41AB INV.QUANTITY,TOTAL INV.QTYT I OTY 110 MOD. OPERATING CURRENT(IMP) MODULE SPEC AMPS(oc) 8.50 TOTAL SYSTEM OUTPUT,IMAXTS (IAC°INV.OTYT) I AMPS(Ad 1 9.00 AIAL MOD.SHORT CCT.CURRENT(ISO) MODULE SPEC AMPS 00 9.00 MOD. MAXIMUM CURRENT(IMAX) OSC° 1.25) AMPS(oa) 11.25 MIN.AMPACITY REO'D,PER NEC (IMAX• 1.25) AMPS(00 14.06 SERIES FUSE RATING,MAX MODULE SPEC AMPS(oc) 15 ELECTRICAL EQUIPMENT SCHEDULE KEY QTY MANUFACTURER MODEL NOTES TRADE I 10 HYUNDAI HIS-S265RG(265W) PV MODULE SOLAR 2 10 ENPHASE M215-60-2LL-S22-IG PV INVERTER SOLAR Is shall not be co 3 1 RSTC/501-ADECK 0786-3R5 PV ROOF JUNCTION BOX,NEMA 3R SOLAR 4 1 CUTLER-HAMMER DG221URB PV AC DISCONNECT,NEMA 3R,240V.30A SOLAR on of an) IOVISII 5 1 ENPHASE ENVOY PV DATA MONITOR, 12OV SOLAR p 6 1 TBD TBD 120V DEDICATED RECEPTACLE FOR ENVOY PV DATA MONITOR SOLAR ices. Thi set of 7 1 TBD TBD CATS PORT FOR SOLAR PV INTERNET CONNECTION TO HOME NETWORK BOX SOLAR 8 NOTE CUTLER-HAMMER TBD PV BRANCH CIRCUIT BREAKERS;I X ISA-IP(ENVOY) SOLAR 1. 9 NOTE CUTLER-HAMMER TBD PV BREAKER.I X 20A-2P.LOCATE AT OPPOSITE ENO OF BUS FROM MAIN BREAKER SOLAR 10 TBD TBD SERVICE PANEL,MIN. 125A BUS BLDR.ELEC. II 1 TBD TBD UTILITY METER,IPH.120/24OV,200A BLOR.ELEC. 12 1 1 1 TBD I TBD I GROUNDING ELECTRODE LIFER I BLDR.ELEC. CONDUCTOR SIZING CALCULATIONS INTERCONNECTION CALCULATIONS D CONDITION OF USE(COU): I(AMPACITY'TEMP.DERATE • FILL DEBATE)VG. REO'D(IMAX) ITEM UNIT PANEL 2)TERMINALS(TERM): I AMPACITY AT TERMINALS.A REO'D,(IMAX° 1.25) PANEL MFR. CUTLER-HAMMER KEY SIZE CU/AL INSULATION CALC. AMPACITY W/O TEMP. FILL RESULT REO'D OCD BUS RATING AMPS 200 TYPE DERATES DERATE DERATE (A) (A) USED(A) MAIN DISCONNECT AMPS 200 A #12 Cu THWN-2 COU 30 0.76 1.0 22.80 9.00 ALLOWED PV PER NEC AMPS 40 TERM 25 1 25 11.25 20 PV OCPD DEVICE USED AMPS 20 B #10 CU NM-B COU 40 0.91 1.0 36.40 9.00 TERM 35 35 11.25 20 C #10 CU NM-B COU 40 0.91 1.0 1 36.40 9.00 TERM 35 35 11.25 20 CONDUCTOR SCHEDULE KEY I CONDUCTORS CWAL TYPE LOCATION TRADE A I-#12 ENGAGE CABLE,1-#6G.FREE AIR CU TC-ER ARRAY SOLAR B I 3-#10,1-#10 EGG I CU I NM-0(ROMEX) INTERIOR SOLAR C 1 3410,1410 EGC I CU I NM-B(ROMEX) INTERIOR SOLAR 5 6 11 D I CAT5E.ETHERNET CABLE I CU I CAT5E INTERIOR SOLAR 7 • o M - SEE NOTE 15 I 10 O IGUIP O O O 'N G G_J A B C 15 I I I ROOF EXTERIOR-GARAGE ELECTRICAL DIAGRAM 2.65 KW LOT#87 ORIGINAL BY: BRI MORRIS DATE:15.10.0 LENNAR: 5 CAMELLIA AT REVIEWED BY:JIMMY METER I DATE:15,10.05 980 MONTECITO DRIVE.#302 THE LAKES CORONA,CA 92879 REV.# BY DATE DESCRIPTION namaste sosee DWG TITLE: PAGE#: SCALE: SITE LOCATION: INDIVIDUAL 4571lder,C 8D304 l PLOT PLAN 2 NTS 2971E GLENNEIRE WAY Boulder,CO ELECTRICAL MENIFEE.CA 303.497.0300 STRUCTURAL NOTES: SOLAR CONTRACTOR- U ALL PV ROOF ATTACHMENTS WILL BE SPACED ALONG MODULE RACKING RAILS AT NOT GREATER THAN 48'O.C. 2)ALL PV ROOF ATTACHMENTS WILL BE STAGGERED BY ROW AMONGST THE ROOF FRAMING MEMBERS,TO MAXIMUM EXTENT POSSIBLE. 3)ROOF PENETRATIONS ASSOCIATED WITH SOLAR RACKING WILL BE SEALED WITH AN APPROVED SEALANT. 4)SOLADECK WIRE TRANSITION BOX WILL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS. IT WILL BE FLASHED AND SEALED. 5)PV ARRAY WILL BE A MINIMUM OF 3-ABOVE THE COMPOSITE SHINGLE ROOF SURFACE. 6)THE UNIRAC SOLARMOUNT RACKING SYSTEM AND SOLAR PV ARRAY WILL BE INSTALLED ACCORDING TO THE UNIRAC SOLARMOUNT CODE-COMPLIANT INSTALLATION MANUAL.VERSION 227.3,PUB 140113-ICC.JANUARY 20M. 7)UNIRAC TOP CLAMPS REQUIRE A ONE INCH 01 SPACE BETWEEN PV MODULES.SOLARMOUNT RAILS MUST EXTEND A MINIMUM OF TWO INCHES(21 BEYOND THE EDGE OF THE PV ARRAY/SUB-ARRAY. �PA/ttw I 8)UNIRAC SOLARMOUNT REQUIRES THAT A THERMAL EXPANSION GAP BE INSTALLED FOR ANY RAIL LENGTH OF GREATER THAN 40'. ROOFING CONTRACTOR- U DISTANCE BETWEEN ARRAY EDGE AND TRANSITION FLASHING(COMPOSITION TO TILE)WILL BE A MINIMUM OF 3'. 2)26 GAUGE INTERLOCKING FLASHING'SIDEWALL'TO BE INSTALLED ALONG THE LENGTH OF THE PV ARRAY AT ROOFING MATERIAL TRANSITION. IT SHALL BE APROVED PRIOR TO PV SYSTEM INSTALLATION. 3)PEEL-N-STICK BASE TO BE INSTALLED ONE FOOT(P)OR MORE BEYOND THE EDGE OF THE COMPOSITION SHINGLE,DOWN TO THE ROOF EAVE.PEEL-N-STICK BASE TO BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS. 4)AREAS UNDER EACH PV ARRAY SHALL BE ROOFED WITH COMPOSITION SHINGLE. COMPOSITION SHINGLE SHALL RUN FROM ABOVE THE PV ARRAY TO THE ROOF EAVE. 5)TILE INSTALLED BELOW THE ARRAY TO BE INSTALLED ABOVE THE COMPOSITION ROOF PER ROOFER SPECIFICATIONS. 6)BIRDSTOP WILL BE INSTALLED AT THE UPPERMOST TRANSITION FROM TILE TO COMPOSITION SHINGLE.BIRDSTOP TO BE SPECIFIED BY ROOFER PRIOR TO INSTALLATION, A to be it the fed ved pla) ELECTRICAL NOTES: GENERAL- U ALL PV EQUIPMENT WILL BE TESTED AND LISTED FOR ITS USE BY A NATIONALLY RECOGN12ED TESTING LABORATORY(NRTL). 2)THE GROUNDING OF THE PHOTOVOLTAIC SYSTEM SHALL COMPLY WITH THE APPLICABLE VERSION OF THE NEC/CEC. 3)ALL GROUNDING ELECTRODE CONDUCTORS WILL BE INSTALLED IN A CONTINUOUS LENGTH EXCEPT WHERE SPLICED BY AN IRREVERSIBLE CONNECTOR OR EXOTHERMIC WELD. 4)NON-CURRENT CARRYING METAL PARTS SHALL BE CHECKED FOR PROPER GROUNDING,NOTING THAT TERMINAL LUGS BOLTED ON AN ENCLOSURE'S FINISHED SURFACE MAY BE ELECTRICALLY INSULATED BECAUSE OF PAINT/FINISH. PAINT/FINISH AT POINT OF CONTACT SHALL BE PROPERLY REMOVED. 5)ROOF PENETRATIONS WILL BE COMPLETED AND SEALED PER APPLICABLE CODE. 6)ALL CONDUCTORS WILL HAVE A 90-C RATING TO ENSURE CODE COMPLIANCE. SOLAR CONTRACTOR- 7)MODULE CERTIFICATIONS WILL INCLUDE U1.1703, IEC61646,IEC61730. 8)CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS. 9)RACEWAY POINT OF PENETRATION FROM EXTERIOR TO INTERIOR WILL BE SEALED TO PREVENT INGRESS OF WATER AND INSECTS. 10)DC WIRING IS LIMITED TO PV ARRAY FOOTPRINT W/ENPHASE MICRO-INVERTER SYSTEM. IU MODULE AND ENPHASE WIRING SHALL BE LOCATED AND SECURED UNDER THE ARRAY USING SUITABLE WIRING CLIPS.WIRING SHALL NOT MAKE CONTACT WITH THE ROOF SURFACE AND SHALL BE MANAGED IN A WORKMAN-LIKE MANNER. 12)EQUIPMENT GROUNDING CONDUCTORS WILL BE SIZED IN ACCORDANCE WITH NEC TABLE 250.122. 13)CONDUCTOR TERMINATIONS WILL BE TORQUED PER DEVICE LISTING,OR MANUFACTURER'S RECOMMENDATIONS. 14)A PV AGGREGATION PANEL(SUB PANEL)WILL NOT BE INCLUDED FOR SYSTEMS WITH ONE BRANCH CIRCUIT. 15)A DEDICATED 120V BRANCH CIRCUIT IS REQUIRED IN MASTER CLOSET(OR EQUIVALENT)FOR ENPHASE ENVOY MONITOR. SIGNAGE- 16)PV SYSTEMS SHALL BE CLEARLY MARKED IN ACCORDANCE WITH NEC ARTICLE 690 AND OTHER APPLICABLE STATE AND LOCAL CODES. 17)ALL SAFETY MARKING/PLACARDS SHALL BE PERMANENTLY ATTACHED BY ADHESIVE OR OTHER MECHANICAL MEANS. 18)MARKING/PLACARDS WILL BE METAL OR PLASTIC WITH ENGRAVED OR MACHINE PRINTED LETTERING. BACKGROUND WILL BE RED WITH WHITE CAPITAL LETTERING OF MINIMUM HEIGHT''. 19)ALL WIRING/RACEWAYS/JUNCTION BOXES WILL BE MARKED'PHOTOVOLTAIC POWER SOURCE,OR EQUIVALENT;WIRING/RACEWAYS SHALL BE MARKED EVERY 10'. BUILDER ELECTRICAL AND SOLAR CONTRACTORS- 20)INSTALLATION SHALL BE COMPLETED IN A NEAT AND WORKMAN-LIKE MANNER. 21)SPACE REQUIREMENTS FOR ALL ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110.26. LENNAR: ORIGINAL BY: BRI MORRIS DATE:15.10.05 CAMELLIA AT 980 MONTECITO DRIVE.9302 REVIEWED BY:JIMMY METER I DATE:15.10.05 THE LAKES CORONA,CA 92879 REV.# BY DATE DESCRIPTION •� namast:6 DWG TITLE: PAGE#: SCALE: SITE LOCATION: INDIVIDUAL 4871 Broadway SVeet PLOT PLAN 3 NTS 29712 GLENNEYRE WAY B001der,CO 80304 NOTES MENIFEE.CA 303.447.0300 CAUTION: POWER TO THIS BUILDING IS SUPPLIED BY THE UTILITY AND A SOLAR PV SYSTEM. DISCONNECTS ARE LOCATED AS SHOWN. ATI �itfor, ran 5p4CECR XBRE ete or ItY TR6VSi BOX, ONMR.,k" t be ke it on th PV e[.pIYBMfcT E%TEPIW-LCNG4E IITILIIY Iffp ' ILIN SERVICE BNEL (uEPIF@p Br BuupEnl SERVICE BY QUALIFIED PERSONNEL ONLY CONTACT: SUNSTREET ENERGY GROUP 1-877-SLR-POWR PV POWER SOURCE - AC SPECS AC OPERATING VOLTAGE: 240 V AC OPERATING CURRENT: 9.0 A NOTE: SEE MASTER SET FOR ADDITIONAL PLACARD INFORMATION LENNAR ORIGINAL BY: BRI MORRIS DATE:IS.I0.05 CAMELLIA AT 980 MONTECITO DRIVE.#302 REVIEWED BY:JIMMY METER DATE:15.10.05 THE LAKES CORONA,CA 92879 REV.# BY DATE I DESCRIPTION nami &MAN DWG TITLE: PAGE#: SCALE: SITE LOCATION: 4S71 Bmzdw Street INDIVIDUAL 29712 GLENNEYRE WAY Boulder,CO 80304 PLOT PLAN 4 NTS PLACARDS MENIFEE,CA 303.447.0300