Loading...
PMT15-03891 City of Menifee Permit No.: PMT15-03891 29714 HAUN RD. Type: Residential Electrical �ACCELA—> MENIFEE,CA 92586 MENIFEE Date Issued: 12/23/2015 PERMIT Site Address: 29688 GLENNEYRE WAY, MENIFEE, CA Parcel Number: 92584 Construction Cost: $6,943.00 Existing Use: Proposed Use: Description of SOLAR TR 30422-3 CAMELLIA Work: 10 MODULES 2.65KW LOT 85 Owner Contractor LENNAR HOMES OF CA LENNAR HOMES OF CALIFORNIA INC 980 MONTECITO DR#302 25 ENTERPRISE CORONA, CA 92879 ALSO VIEJO,CA 92656 Applicant Phone: 9493498269 JEREMIAH ACAYTURRI License Number.728102 LENNAR HOMES OF CALIFORNIA INC 25 ENTERPRISE ALISO VIEJO, CA 92656 Fee Description G1yt Amount fEl Solar, Residential or Small Commercial 1 252.00 Building Permit Issuance 1 27.00 GREEN FEE 1 1.00 SMIP RESIDENTIAL 1 1.00 General Plan Maintenance Fee-Electrical 1 12.60 $293.60 The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and specifications or from preventing builiding operations being carried on thereunder when in violation of the Building Code or of any other ordinance of City of Menifee.Except as otherwise stated,a permit for construction under which no work is commenced within six months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be forfeited. AA_Bldg_Permit_Templale.rpt Page 1 of 1 BUILDING & SAFETY PERMIT/PLAN CHECK APPLICATION kb'�M� Menifee 1111 DATE 12/15/2015 PERMIT/PLAN CHECK NUMBER M ( I6`O-3U , TYPE: ❑COMMERCIAL ❑✓ RESIDENTIAL MULTI-FAMILY ❑MOBILE HOME ❑ POOL/SPA ❑SIGN SUBTYPE: ❑✓ ADDITION []ALTERATION [-]DEMOLITION ❑ELECTRICAL [:]MECHANICAL ❑NEW []PLUMBING [-IRE-ROOF-NUMBER OF SQUARES DESCRIPTION OF WORK Solar Permit-Plan 2077-2.65 kW/10 PCS Master Solar Permit No. PMT14-02630 PROJECT ADDRESS 29688 Glenneyre Way, Menifee, CA 92584 ASSESSOR'S PARCEL NUMBER LOT S5 TRACT 30422-3 PROPERTY OWNER'S NAME Lennar Homes of California, Inc. ADDRESS 980 Montecito Dr.,Suite 302,Corona,CA 92879 PHONE (951)817-3680 EMAIL leremiah.acayturri@lennar.com APPLICANT NAME Lennar Homes of California, Inc. ADDRESS 980 Montecito Dr., Suite 302,Corona,CA PHONE (951)817-3680 EMAIL leremiah.acayturri@lennar.com CONTRACTOR'S NAME Lennar Homes of California, Inc. OWNER BUILDER? OYES❑NO BUSINESS NAME Lennar Homes of California, Inc. ADDRESS 980 Montecito Dr.,Suite 302,Corona,CA PHONE (951)817-3680 EMAIL Jeremiah.acayturri@lennarcom CONTRACTOR'S STATE LIC NUMBER 728102 LICENSE CLASSIFICATION A&B VALUATION$ $6.943.00 SQ FT L SO FT APPLICANT'S SIGNATURE DATE 12/15/2015 CITYSTAFF USE ONLY DEPARTMENT DISTRIBUTION GREEN SMIP je) CITY OF MENIFEE BUSINESS LICENSE NUMBER BUILDING PLANNING ENGINEERING FIRE INVOICE -t � OO PAIDAMOUNT O O AMOUNT CASH CHECK!! ;S CREDITCARD VISA/MC PLAN CHECK FEES PAIDAMOUNT OCASH OCHECK# OCREDITCARD VISA/MC OWNER BUILDER VERIFIED OYES O NO DL NUMBER NOTARIZED LETTER O YES O NO City of Menifee Building&Safety Department 29714 Houn Rd. Menifee, CA 92586 951-672-6777 www.cityofinenifee.us Inspection Request Line 951-246-5213 SYSTEM INFORMATION BUYER ACKNOWLEDGES THAT THE SOLAR MODULES TO BE INSTALLED ITEM OTY 1 MFR. MODEL ON THE ROOF OF THE HOME WILL BE SUBSTANTIALLY IN THE SYSTEM SIZE 1 2.65 KW LOCATIONS INDICATED BY THE ILLUSTRATION. MODULE IO PCS.1 HYUNDAI HIS-S265RG(265W) BUYER: INVERTER 1 10 PCS.1 ENPHASE I M215-60-2LL-S22-IG [' ROOF TYPE TILE W/COMPOSITE SHINGLE UNDER ARRAY DATE: CITYOF ENII SUB-ARRAY INFORMATION ARRAY#1 ARRAY#2 ARRAY#3 p�I' ^ MOD OTY IO NA NA BUYER: D UIN ANI TILT 23° NA' NA' �• AZIMUTH 270° NA' NA' of PI 0�/ Building Dept Y DEC 2 1 2015 REVIEWE 00- Received bnrovdo(these Dfanssf approval of,any vic ation o regulations and Ord nances, 10'-10 6-10• ICOSlte until comple ion. --- ---- --------------- � I I - I I - I I I 9 I 1 I I I tz h LL - I I I I I I SOLADECK WIRE I TRANSITION BOX (UNDER ARRAY) PV AC DISCONNECT I EXTERIOR-GARAGE UTILITY METER& I I MAIN SERVICE PANEL ——— — (VERIFIED BY BUILDER) ———— —— —— �1 rIIIIIIIIS NOTE:DIMENSIONS ARE SHOWN IN PLANE OF ROOF N ®w PLAN 2077 ELEVATION A ORIENTATION I LOT#65 4� ORIGINAL BY: BRI MORRIS I DATE:IS.IO.OS CAMELLIA AT LENNAR: 980 MONTECITD DRIVE,#302 REVIEWED BY:JIMMY METER I DATE:15.10.05 THE LAKES CORONA.CA 92879 REV.# BY DATE I DESCRIPTION •� n SOLAR 45 DWG TITLE: PAGE#: SCALE: roue SITE LOCATION: 4571 Braatlway SVeal w INDIVIDUAL 29688 GLENNEYRE WAY Boulder,GO 60304 PLOT PLAN 1 1/16'=1'-0' MENIFEE,CA 303.447.0300 SYSTEM LAYOUT MODULE SPECS AND CALCULATIONS INVERTER SPECS AND CALCULATIONS ITEM NOTE/CALC UNIT DETAIL ITEM NOTE/CALC UNIT DETAIL LOCATION MENIFEE.CA INV. MAKE INVERTER SPEC ENPHASE TEMP.AMBIENT HIGH(TMAX) ASHRAE 2% °C 37 INV. MODEL INVERTER SPEC M215-60-2LL-S22-IG TEMP.AMBIENT LOW(THIN) ASHRAE EXTR.MIN °C -2 INV. MAX POWER,(WAc MAX) INVERTER SPEC WATTS(Ac) 225 TEMP,MODULE TEST(TTEST) MODULE SPEC °C 25 INV. INPUT V.(Voc MAX) INVERTER SPEC VOLTS(00 48 TEMP,DELTA LOW(TEELTA) THIN-TTEST 'C -27 INV.OUTPUT V.(Vac MOM) INVERTER SPEC VOLTS(AC) 240 MOD. MANUFACTURER MODULE SPEC HYUNDAI INV.OUTPUT FREQUENCY INVERTER SPEC HERTZ 60 MOD. PART NUMBER MODULE SPEC HIS-S265RG INV.OUTPUT CURRENT,IAG INVERTER SPEC AMPS(AC) 0.9 C MOD. POWER STC(P) MODULE SPEC WATTS(DU 265 INV.PHASE QUANTITY INVERTER SPEC PHASE I DE MOD. POWER PTC MODULE SPEC WATTS(DC) 238 COMPLIANCE INVERTER SPEC UL1741/lEEEI547 MOD. OPERATING VOLTAGE(VHP) MODULE SPEC VOLTS(DC) 31.30 INV. GROUNDING INVERTER SPEC ISOLATED MOD.OPEN CCT. VOLTAGE WOO) MODULE SPEC VOLTS(od 38.10 INV.QTY,MAX/BRANCH CCT. INV..'0 QTY 10 MOD.COEFF.VOLT/TEMP(COEF) MODULE SPEC V/°C -0.114 BRANCH CCT.OUTPUT,IMAXGC (IAC•INV.GTYBC) AMPS(AO) 9.00 MOD. MAX VOLTAGE(VMAXMOD) (Vac+(TD•COEF)) VOLTS(DG) 41.18 INV.QUANTITY,TOTAL INV.QTVi QTV 10 MOD.OPERATING CURRENT UHP) MODULE SPEC AMPS(DC) 6.50 TOTAL SYSTEM OUTPUT.IMAXTS (IAC-INV,GTYT) I AMPS(AC) 9.00 MOD.SHORT CCT.CURRENT(Isc) MODULE SPEC AMPS(DO) 9.00 MOD. MAXIMUM CURRENT(TMAX) (Isc• 1.25) AMPS(DO) 11.25 MIN.AMPACITY REQ'D,PER NEC (TMAX'1.255 AMPS(DC) 14.06 SERIES FUSE RATING,MAX MODULE SPEC AMPS(130 15 ELECTRICAL EQUIPMENT SCHEDULE KEY QTY MANUFACTURER MODEL NOTES TRADE �(68 Co IstruWI 1 10 HYUNDAI HIS-S265RG(265W) PV MODULE SOLAR 2 10 ENPHASE M215-60-2LL-S22-IG PV INVERTER SOLAR ''I1!VISI AA��n$of IU( 3 1 RSTC/SOLADECK 0786-3115 PV ROOF JUNCTION BOX,NEMA 3R SOLAR 4 1 CUTLER-HAMMER DG221URS PV AC DISCONNECT.NEMA 3R,240V,30A SOLAR of i proved 5 1 ENPHASE ENVOY PV DATA MONITOR.120V SOLAR 6 1 TBO TBD 120V DEDICATED RECEPTACLE FOR ENVOY PV DATA MONITOR SOLAR 7 1 TBD TBD CATS PORT FOR SOLAR PV INTERNET CONNECTION TO HOME NETWORK BOX SOLAR B NOTE CUTLER-HAMMER TBD PV BRANCH CIRCUIT BREAKERS:I X 15A-IP(ENVOY) SOLAR 9 NOTE CUTLER-HAMMER TBD PV BREAKER.I x 2OA-2P,LOCATE AT OPPOSITE END OF BUS FROM MAIN BREAKER SOLAR 10 TBD TBD SERVICE PANEL.MIN. 125A BUS BLDR.ELEC. II I TBD TBD UTILITY METER.IPH.12a/240V,200A 8LDR.ELEC. 12 11 1 TBD I TBD I GROUNDING ELECTRODE UFER I BLDR.ELEC. CONDUCTOR SIZING CALCULATIONS INTERCONNECTION CALCULATIONS U CONDITION OF USE(COLD: EAMPACITY MP.DERATE•FILL DERATE)vs.REDID(TMAX) ITEM UNIT PANEL 2)TERMINALS(TERM): ERMINALS.vs.REG'D,(IMAX• 1.25) PANEL MFR. CUTLER-HAMMER KEY SIZE CU/AL INSULATION CALC. TEMP. FILLRESULT REO'D OCD BUS RATING AMPS 200 TYPE DERATE DERATE (A) (A) USED(A) MAIN DISCONNECT AMPS 200 A #12 CU THWN-2 COU 0.76 1.0 22.80 9.00ALLOWED PV PER NEC AMPS 40 TERM 25. 11.25 20 PV OCPD DEVICE USED AMPS 20 #10 CU NM-B COU 0.91 1.0 36.40 9.00 TERM 35 11.25 20 #10 CUNM-B COU 0.91 L0 36.40 9.00 TERM 35 11.25 20 CONDUCTOR SCHEDULE KEY CONDUCTORS 1 CU/AL 1 TYPE LOCATION TRADE q I-#12 ENGAGE CABLE.1-#6G,FREE AIR CU Y SOLAR TC-ER ARRA B 3-#10,1-#10 EGC ICU I NM-B(ROMEX) INTERIOR SOLAR C 3-#10,I-#10 EGC CU NM-B(ROMEX) INTERIOR SOLAR 5 6 II D CAT5E.ETHERNET CABLE Cu CATSE INTERIOR. SOLAR o 7 • O SEE NOTE I5 I 10 p150 I 2 9 O O O za 3 _ _IN G D� A B C =Ip I 1 I ROOF EXFERIOR-GARAGE ELECTRICAL DIAGRAM 2.65 KW LOT#85 ORIGINAL BY: BRI MORRIS I DATE:I5.10.05 CAMELLIA AT LENNAR: 980 MONTECITO DRIVE,#302 REVIEWED BY:JIMMY METER I DATE:15.10.05 THE LAKES CORONA,CA 92879 REV.# BY DATE DESCRIPTION Oniamasbii sauv DWG TITLE: PAGE#: SCALE: SITE LOCATION: INDIVIDUAL 4B Broadway CO 80304 PLOT PLAN 2 NTS 29688 GLENNEYRE WAY Bo3We4 708o300 ELECTRICAL MENIFEE,CA 303.447.0300 STRUCTURAL NOTES: SOLAR CONTRACTOR- D ALL PV ROOF ATTACHMENTS WILL BE SPACED ALONG MODULE RACKING RAILS AT NOT GREATER THAN 48'O.C. 2)ALL PV ROOF ATTACHMENTS WILL BE STAGGERED BY ROW AMONGST THE ROOF FRAMING MEMBERS,TO MAXIMUM EXTENT POSSIBLE. 3)ROOF PENETRATIONS ASSOCIATED WITH SOLAR RACKING WILL BE SEALED WITH AN APPROVED SEALANT. 4)SOLADECK WIRE TRANSITION BOX WILL BE INSTALLED.PER MANUFACTURER'S INSTRUCTIONS. IT WILL BE FLASHED AND SEALED. 5)PV ARRAY WILL BE A MINIMUM OF 3'ABOVE THE COMPOSITE SHINGLE ROOF SURFACE. 6)THE UNIRAC SOLARMOUNT RACKING SYSTEM AND SOLAR PV ARRAY WILL BE INSTALLED ACCORDING TO THE UNIRAC SOLARMOUNT CODE-COMPLIANT INSTALLATION MANUAL,VERSION 227.3.PUB 140113-ICC,JANUARY 2014. 7)UNIRAC TOP CLAMPS REQUIRE A ONE INCH(1')SPACE BETWEEN PV MODULES.SOLARMOUNT RAILS MUST EXTEND A MINIMUM OF TWO INCHES(29 BEYOND THE EDGE RTMI OF THE PV ARRAY/SUB-ARRAY. 8)UNIRAC SOLARMOUNT REQUIRES THAT A THERMAL EXPANSION GAP BE INSTALLED FOR ANY RAIL LENGTH OF GREATER THAN 40'. ROOFING CONTRACTOR- U DISTANCE BETWEEN ARRAY EDGE AND TRANSITION FLASHING(COMPOSITION TO TILE)WILL BE A MINIMUM OF 3'. 2)26 GAUGE INTERLOCKING FLASHING'SIDEWALL'TO BE INSTALLED ALONG THE LENGTH OF THE PV ARRAY AT ROOFING MATERIAL TRANSITION. IT SMALL BE APROVED PRIOR TO PV SYSTEM INSTALLATION. 3)PEEL-N-STICK BASE TO BE INSTALLED ONE FOOT(1)OR MORE BEYOND THE EDGE OF THE COMPOSITION SHINGLE,DOWN TO THE ROOF EAVE.PEEL-N-STICK BASE TO BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS. 4)AREAS UNDER EACH PV ARRAY SMALL BE ROOFED WITH COMPOSITION SHINGLE.COMPOSITION SHINGLE SHALL RUN FROM ABOVE THE PV ARRAY TO THE ROOF EAVE. 5)TILE INSTALLED BELOW THE ARRAY TO BE INSTALLED ABOVE THE COMPOSITION ROOF PER ROOFER SPECIFICATIONS. 6)BIRDSTOP WILL BE INSTALLED AT THE UPPERMOST TRANSITION FROM TILE TO COMPOSITION SHINGLE. BIRDSTOP TO BE SPECIFIED BY ROOFER PRIOR TO INSTALLATION. a Permit 1 ral,gap I s must b( ELECTRICAL NOTES: GENERAL- D ALL PV EQUIPMENT WILL BE TESTED AND LISTED FOR ITS USE BY A NATIONALLY RECOGNIZED TESTING LABORATORY(NRTL). 2)THE GROUNDING OF THE PHOTOVOLTAIC SYSTEM SHALL COMPLY WITH THE APPLICABLE VERSION OF THE NEC/CEC. 3)ALL GROUNDING ELECTRODE CONDUCTORS WILL BE INSTALLED IN A CONTINUOUS LENGTH EXCEPT WHERE SPLICED BY AN IRREVERSIBLE CONNECTOR OR EXOTHERMIC WELD. 4)NON-CURRENT CARRYING METAL PARTS SHALL BE CHECKED FOR PROPER GROUNDING,NOTING THAT TERMINAL LUGS BOLTED ON AN ENCLOSURE'S FINISHED SURFACE MAY BE ELECTRICALLY INSULATED BECAUSE OF PAINT/FINISH. PAINT/FINISH AT POINT OF CONTACT SHALL BE PROPERLY REMOVED. 5)ROOF PENETRATIONS WILL BE COMPLETED AND SEALED PER APPLICABLE CODE. 6)ALL CONDUCTORS WILL HAVE A 90-C RATING TO ENSURE CODE COMPLIANCE. SOLAR CONTRACTOR- 7)MODULE CERTIFICATIONS WILL INCLUDE U1_1703.IEC61646, IEC61730. 8)CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS. 9)RACEWAY POINT OF PENETRATION FROM EXTERIOR TO INTERIOR WILL BE SEALED TO PREVENT INGRESS OF WATER AND INSECTS. 10)DC WIRING IS LIMITED TO PV ARRAY FOOTPRINT W/ENPHASE MICRO-INVERTER SYSTEM. 11)MODULE AND ENPHASE WIRING SHALL BE LOCATED AND SECURED UNDER THE ARRAY USING SUITABLE WIRING CLIPS.WIRING SHALL NOT MAKE CONTACT WITH THE ROOF SURFACE AND SHALL BE MANAGED IN A WORKMAN-LIKE MANNER. 12)EQUIPMENT GROUNDING CONDUCTORS WILL BE SIZED IN ACCORDANCE WITH NEC TABLE 250.122. 13)CONDUCTOR TERMINATIONS WILL BE TORQUED PER DEVICE LISTING,OR MANUFACTURER'S RECOMMENDATIONS. 14)A PV AGGREGATION PANEL(SUB PANEL)WILL NOT BE INCLUDED FOR SYSTEMS WITH ONE BRANCH CIRCUIT. 15)A DEDICATED 120V BRANCH CIRCUIT IS REQUIRED IN MASTER CLOSET(OR EQUIVALENT)FOR ENPHASE ENVOY MONITOR. SIGNAGE- 16)PV SYSTEMS SHALL BE CLEARLY MARKED IN ACCORDANCE WITH NEC ARTICLE 690 AND OTHER APPLICABLE STATE AND LOCAL CODES. 17)ALL SAFETY MARKING/PLACARDS SHALL BE PERMANENTLY ATTACHED BY ADHESIVE OR OTHER MECHANICAL MEANS. IS)MARKING/PLACARDS WILL BE METAL OR PLASTIC WITH ENGRAVED OR MACHINE PRINTED LETTERING.BACKGROUND WILL BE RED WITH WHITE CAPITAL LETTERING OF MINIMUM HEIGHT il'. 19)ALL WIRING/RACEWAYS/JUNCTION BOXES WILL BE MARKED*PHOTOVOLTAIC POWER SOURCE;OR EQUIVALENT:WIRING/RACEWAYS SHALL BE MARKED EVERY 10% BUILDER ELECTRICAL AND SOLAR CONTRACTORS- 20)INSTALLATION SHALL BE COMPLETED IN A NEAT AND WORKMAN-LIKE MANNER. 21)SPACE REGUIREMENTS FOR ALL ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110.26. ORIGINAL BY: BRI MORRIS I DATE:I5. LENNAR: 10.05 CAMELLIA AT REVIEWED BY:JIMMY METER DATE:15.10.05 980 MONTECITO DRIVE,#302 THE LAKES CORONA,CA 92879 REV.# BV DATE DESCRIPTION 41 namaste am�e DWG TITLE: PAGE#: SCALE: SITE LOCATION: 4571 B.a".y Street INDIVIDUAL 29688 GLENNEYRE WAY BoNtler,CO,SON PLOT PLAN 3 NTS MENIFEE.CA 803.447.0300 NOTES CAUTION: POWER TO THIS BUILDING IS SUPPLIED BY THE V r UTILITY AND A SOLAR PV SYSTEM. DISCONNECTS ARE LOCATED AS SHOWN. 0Dj TE ora city of D the soLeoEu VrIRE Tnuamox Eox TIMER umnvl PV eCOI=GWCT E%IERIgi-GPRPLE VIILIT1 METER G WINS RAM PWL (ERIFhO eY WLbER) hL SERVICE BY QUALIFIED PERSONNEL ONLY CONTACT: SUNSTREET ENERGY GROUP 1-877-SLR-POWR PV POWER SOURCE - AC SPECS AC OPERATING VOLTAGE: 240 V AC OPERATING CURRENT: 9.0 A NOTE: SEE MASTER SET FOR ADDITIONAL PLACARD INFORMATION ORIGINAL BY: BRI MORRIS DATE:15.10.05 CAMELLIA AT LENNAR: 980 MONTECITO DRIVE,#302 REVIEWED BY:JIMMY METER DATE:IS.10.05 THE LAKES CORONA,CA 92379 REV.# BY DATE I DESCRIPTION •, namaste so LA.e DWG TITLE: PAGE#: I SCALE: SITE LOCATION: 4571 B.d.yStreet INDIVIDUAL 29608 GLENNEYRE WAY BmIder,CO 60304 PLOT PLAN A NTS MENIFEE,CA 303.447.0300 PLACARDS