PMT15-03768 City of Menifee Permit No.: PMTIS-03768
29714 HAUN RD. Type: Residential Plumbing
<A—CCECA/ ? MENIFEE, CA 92586
MENIFEE Date Issued: 1 210 9/2 01 5
PERMIT
Site Address: 30975 GREEN BRANCH DR, MENIFEE, Parcel Number: 360-463-038
CA 92584 Construction Cost:. $2,700.00
Existing Use: Proposed Use:
Description of INSTALL NEW TANKLESS WATER HEATER
Work:
Owner Contractor
DAVID JOHNSON W C HEATING&AIR CONDITIONING INC
30975 GREEN BRANCH DRIVE 41085 GOLDEN GATE CIR
MENIFEE,CA 92584 MURRIETA,CA 92562
Applicant Phone:9516000700
RUSSELL COCHRAN License Number:779604
WE CARE HEATING&AIR CONDITIONING INC
41085 GOLDEN GATE CIR
MURRIETA, CA 92562
Fee Description Qtv Amount 1$1
Residential Water Heater 1 83.00
Building Permit Issuance 1 27.00
GREEN FEE 1 1.00
General Plan Maintenance Fee-Plumbing 1 4.15
$115.15
The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and
specifications or from preventing builiding operations being carried on thereunder when in violation of the Building Code or of any other
ordinance of City of Menifee.Except as otherwise stated,a permit for construction under which no work is commenced within six
months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be
forfeited.
AA_Bldg_Permit_Template.rpt Page 1 of 1
City Of Menifee
LICENSED DECLARATION ❑ lam exempt from licensure under the Contractors'State License Law for the
I hereby affirm under penalty or perjury that I am licensed under provisions of following reason:
Chapter 9(commencing with section 7000)of Division 3 of the Business and By my signature below I acknowledge that, except for my personal residence in
Professions Code and license is in full force and effg,�(, which I must have resided for at least one year prior to completion of
License Cl9ris _License-o. (�460-( improvements covered by this permit, I cannot legally sell a structure that I have
Expires 3 Ar Signature built as an owner-building if it has not been constructed in its entirety by licensed
contractors. I understand that a copy of the applicable law,Section 7044 of the
WORKERS'COMPENSATION DECLARATION Business and Professions Code,is available upon request when this application is
submitted or at the following Web site:
❑ 1 hereby affirm under penalty of perjury one of the following declarations: htto:/Avww.leginfo.m.gov/mlaw.htmi.
I have and will maintain a certificate of consent of self-insure for workers'
compensation,issued by the Director of Industrial Relations as provided for by Date
Section 3700 of the Labor Code, for the performance of work for which this
permit is issued. Property Owner orAuthodzed Agent
Policy# ❑ By my Signature below, I certify to each of the following: I am the property
C�1 have and will maintain workers' compensation insurance, as required by owner or authorized to act on the property owner's behalf. I have read this
section 3700 of the Labor Code, for the performance of the work for which this application and the information I have provided is correct. I agree to comply
permit is issued.My workers'compensation insurance carder and policy number are: with all applicable city and county ordinances and state laws relating to building
construction.I authorize representatives of this city or county to enter the above-
Carder / BLS identified property for the inspection purposes.
Policy# AW6037WC4 Expires ��/ We Date
Property Owner prAuthorized Agent
(This section need not be completed if the permit is for City Business License# ca:r." '
one-hundred dollars($100)or less)
HAZARDOUS MATERIAL DECLARATION
❑ 1 certify that in the performance of the work for which this permit is issued,I
shall not employ any persons in any manner so as to become subject to the Will the applicant or future building occupant handle hazardous material or a
workers'compensation laws of California, and agree that if I should become mixture containing a hazardous material equal to or greater that the
subject to the workers'compensation provisions of Section 3700 of the Labor amounts sp ied on the Hazardous Materials Information Guide?
Code,I shall forthwith comply with those provisiioonss.® DYES
Applicant; C Date; �`y T�� Will the intended use of the building by the applicant or future building
occupant require a permit for the construction or modification from South
WARNING: FAILURE TO SECURE WORKERS' Coast Air Quality Management District(SCAQMD)?See permitting checklist
COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL for guideline
SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND DYES 2I N0
CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS
($100,000), IN ADDITION TO THE COST OF COMPENSATION, Will the proposed building or modified facility be within 1000 feet of the outer
DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE boundary ofa ool?
LABOR CODE, INTEREST,AND ATTORNEYS FEES DYES 5rNO
CONSTRUCTION LENDING AGENCY I have read the Hazardous Material Information Guide and the SCAQMD
I hereby affirm that under the penalty of perjury there is a construction lending permitting checklist.I understand my requirements under the State of
agency for the performance of the work which this permit is issued (Section California Hea1t &Safety Code,Section 25505 and 25534 concerning
3097 Civil Code) hazardous erial reporting.
OWNER BUILDER DECLARATIONS DYES If NO _
I hereby affirm under penalty of perjury that I am exempt from the Contractor'sL- Date 4 �s
License Law for the reason(s)indicated below by the checkmark(s)I have placed PROPERTY OWNER OR AUTHORIZED AGENT
next to the applicable item(s)(Section 7031.5.Business and Professions Code:
Any city or county that requires a permit to construct, alter, improve, demolish, EPA RENOVATION,REPAIR AND PAINTING(RRP)
or repair any structure, prior to its issuance, also requires the applicant for the
permit to file a signed statement that he or she is licensed pursuant to the The EPA Renovation,Repair and Painting(RRP)Rule requires contractors
provisions of the Contractor's State License Law(Chapter 9(commencing with receiving compensation for most work that disturbs paint in a pre-1978
Section 7000)of Division 3 of the Business and Professions Code)or that he or residence or childcare facility to be RRP-certified firms and comply with
she is exempt from licensure and the basis for the alleged exemption. Any required practices.This includes rental property owners and property
Violation of Section 7031.5 by any Applicant for a permit subjects the applicant to managers who do the paint-disturbing work themselves or through their
a civil penalty of not more than($500).) employees.For more information about EPA's Renovation Program visit:
www.epa.gov/lead or contact the National Lead Information Center at
❑ I, as owner of the property, or my employees with wages as their sole 1-800-424-LEAD(5323).
compensation,will do( )all of or( )porting of the work,and the structure is
not intended or offered for sale.(Section 7044,Business and Professions Code;
The Contractor's State License Law does not apply to an owner of a property ❑An EPA Lead-Safe Certified Renovator will be responsible for this project
who, through employees' or personal effort, builds or improves the property,
provided that the improvements are not intended or offered for sale.If,however, Certified Firm Name:
the building or improvement is sold within one year of completion,the Owner-
Builder will have the burden of proving that it was not built or improved for the Firm Certification No.:
purpose of sale).
❑ I, as owner of the property an exclusively contracting with licensed ❑No EPA Lead-Safe Certified Firm is required for this project because:
contractors to construct the project(Section 7044, Business and Professions
Code:The Contractor's License Law does not apply to an owner of a property
who builds or improves thereon, and who contracts for the projects with a
licensed contractor(s)pursuant to the Contractors State License Law). If your project does not comply with EPA RRP rule please fill out the RRP
SAFETY • • APPLICATION
"Menifee
DATE 12/07/2015 PERMIT/PLAN CHECK NUMBER �j—
TYPE: ❑COMMERCIAL ❑✓ RESIDENTIAL ❑MULTI-FAMILY ❑MOBILE HOME ❑POOL/SPA [:]SIGN
SUBTYPE: ❑ADDITION ❑ALTERATION ❑DEMOLITION ❑ELECTRICAL []MECHANICAL
❑NEW ❑✓ PLUMBING ❑RE-ROOF-NUMBER OF SQUARES
DESCRIPTION OF WORK INSTALL TANKLESS WATER HEATER
PROJECTADDRESS 30975 GREEN BRANCH Ckzi%L.
ASSESSOR'S PARCEL NUMBER '3Lg0- LAt,0S - LOT TRACT
PROPERTY OWNER'S NAME DAVID JOHNSON City of Menifee
a ep .
ADDRESS 30975 GREEN BRANCH
PHONE (949)743-4373 EMAIL EC 0 7 .2015
APPLICANT NAME WE GREEN INC.
ADDRESS 4540 KEARNY VILLA RD#213
PHONE (951)600-0700 EMAIL ERIC@WEGREENINC.COM
CONTRACTOR'S NAME RUSSELLCOCHRAN OWNERBUILDER? ❑YES❑✓ NO
BUSINESS NAME WE CARE PLUMING
ADDRESS 41085 GOLDEN GATE CIR.
PHONE (951)600-0700 EMAIL CATWOOD@WECARETEAM.COM
CONTRACTOR'S STATE LIC NUMBER 779604 LICENSE CLASSIFICATION C20
VALUATION$ $2,700.00 SO FT 3090 L SQ FT
APPLICANT'S SIGNATURE DATE
DEPARTMENT DISTRIBUTION CITY OF MENIFEE BUSINESS LICENSE NUMBER
BUILDING PLANNING ENGINEERING FIFE I GREEN SMIP I X
INVOICE PAID AMOUNT
AMOUNT O CASH C)CHECK# O CREDIT CARD VISA/MC
PLAN CHECK FEES PAID AMOUNT 0CASH 0CHECK# OCREDITCARD VISA/MC
OWNER BUILDER VERIFIED OYES O NO DLNUMBER NOTARIZEDLETfER 0 YES 0 NO
City of Menifee Building&Safety Department 29714 Haun Rd. Menifee, CA 92586 951-672-6777
www.cityofinenifee.us Inspection Request Line 951-246-6213
NORITZ
Model NRC1111 Series
Residential Condensing Tankless Water Hepu g&Safety Dept. 0
Specification Sheet DEC 0 7 2015 WU
•Standard Input-gas consumption ranges from 16,000 BTUh to �.
199,900 BTUh 'Received Ll.
•Capacity Range-flow rates from 0.5 gpm up to 11.1 gpm _
•Compact Design-ANSI Z21.10.3/CSA 43 certified design that can be
wall-mounted indoors or outdoors i
•Durable Steel Casing with Polyester Coating ['•�.'
•Heat Exchanger-manufactured with commercial grade copper,
25%thicker piping than standard models
r
•Venting Options-available as an Outdoor(requires no venting)or indoor
Direct Vent(-DV)model which includes special plasticflue adapters that are .. .. I
compatible with both 3"or 4"Schedule 40 and 80 PVC/CPVC pipe.
The DV model can also be converted to an SV model with the use of a
Conversion Kit(#SV-CK-3)
•Direct Electronic Ignition
ODModel DVModel
•Quick-Conned-two identical units can be linked together by using
the optional Quick Connect Cord(#QC-2)for twice the hot water capacity
•Energy Factor-0.92 ING) 0.91 (LP) Model
-_
•Thermal Efficiency-fully condensing,93%efficient for use with natural NRCI111
gas or propane ❑OD(Outdoor Vent)
❑DV(Direct Vent)
•TemperatureControls-includesremotethermostatthatcanprecisely Accessories \v\
adjust the output temperature from 100"F to 140"F with the capability to ❑Horizontal Hood Termination(#PVr HL)
display temperatures in both"C and"F
❑3"PVCTermina[ion(#VK3-H-PVC)
•Power Cord Installation Kit-6'power cord is included with-DV models only ❑Birdscreen for a"PVVCPVC(#Vf3-PVCS)
❑Birdscreen for 4"PVC/CPVC(#VF4-PVCS)
•Safety Devices-Flame Sensor,Overheat Prevention Device, ❑Condensate Neutralizer(#NC-1)
Lightning Protection Device,Freeze Protection,Condensate Overfill
❑Isolation Valves(#1K-WV-200.1)
-Additional Features-TemperatureLockoutHighElevationAdjustment, ❑Pipe Cover(#PC-35)
Condensate Overflow Monitoring System,Service Reminder Function. ❑Quick Connect Cord(#QC-2)
•12-Year"Limited Heat Exchanger Warranty for Residential Use ❑SVConversion Kit(#5V-CK-3)
•5-Year Limited Parts Warranty
•Approvals-CSA,UPC",NSF,Low NOx Approved by SCAQMD[<I 4ng/J or 20ppm],
Suitable for Installation in a Manufactured(Mobile)Home"
O La� O
NSF.
•Heot&changerwarrantyis maintoinedat 12 years or6500 operotionalhours,whichewroccurs first when usedin asingle familydwelling in conjunction with a
connolledrecirculation system(an aquastatbeing the minimum pump control requiremeno in accordance with the Installation Manual.Beferto theNoritzlimited
warranty for complete coverage details
This productcomplies with California AB 1953 Low Lead Law
"'Manufactured(Mobile)Home approval is valid forOD and DV models only
NORTZAMERCA DORDORATION
11160 Grace Avenue,Fountain Valley,CA 92708 Tel.1$IXr7NORTZ www.noritzcom
Dimensions
WROMTDh
Be lam
04-11frapt 9A'f2 .S'15dnn 9.1'%4Nm 737mm sf Wrm E
s.S 74Anml 01.5 B111mm Us,rofl4hm 1S3'd6dmm '^ti s
1.1'(2&Rm) OSY(Naml I I I 1 1 03S'easi m 77.6'446mm AIR INLET FIVE OLIAlt 1A5
>E3
— O O IR T)E
Y tOPI,TUU—
Y
IOL�Ii PA✓WggRJE
ntpr
'AY
MUM1 a—
DVModel
PERM, MW17
Y
AY
Front View OD Model
0.4'OAmmI WRINGTHORWWWAY fE
Side View CONDENSATE DRAIN HEIGHTOFEACH FMING <IxN lmmp _'_ retr t
WATERgLJNVALVE ROMWIMMOFCASEA RAINOIWATERFILTER)HOTWATEROIIILET CODwATERINLET u05" tSlssmml wRWGtmrou mArs 11 1
BOTTOM VIEW GASINLET 7 06mml zz'n61vm1 OD Model
WAIERDRAWVNYE
Flow Rates
Temperature 30 40 45 50 60 70 80 90 100
Rise('F)
Flow Rate 11.1 9.3 8.4 7.4 6.2 5.3 4.6 4.1 3.7
(GPM)
Pressure Loss
>o
I r r
r -1 -1 -1 -i Stl brTereWn:R6Fwbe i 1
1 m
r r I r
36 -Bypem Fqw CaYd WwClwe _l _L
� SSIbmLsedn:lEF>Nyv
2.
E I I I I I
1 I I I I I I N
1 i I 1 I
I I I I I I I I
1 1 1 r
I I tR
i
6 D
o.o La xo ao IA u. 6o tD n0 9.0. 1" na 20
FbwwloFpf
Specifications
Model Name NRC7111-0D NRCl111-0DV
Weight 66(pounds) 68(pounds)
Operating Pressure 15-150 psi
Gas Supply Pressure NG:4.0'-105" LP.8.0'-14.0'
Water Holding Capacity OS Gallon(2 U
Waterinlet 3/4"
Connection Hot Water Oudet 3/4"
Sizes Gas Inlet 3/4"
Condensate Drain 1/2"ThTeaded
Power Supply 120VAC(60Hz),less than 4 amperes
Consumption NG:78W LP:BOW Freeze Prevention 223W NG:B1W LP:83W Freeze Prevention 223W
Freeze Protection Outdoor.-4°F 11 Indoor.-30'F
Temperature Settings °FMode 100-140-Fan 5°Fintervals)(9 Options)
°C Mode 37-48"C(In l"C intervals),50,55,60°C(in 5°C intervals)(15 Options)
DefaultTempersture Opdom °FMode 120,135,140°F(De%ult is 120`n
°C Mode 50,57,60°C(Default is SO°C)
Noritz America reserves the right to discontinue,or change at any time,the designs and/or specifications of its products without notice.
Rev.4/12