Loading...
PMT15-03578 City of Menifee Permit No.: PMT15-03578 29714 HAUN RD. < -�CCEL/-> MENIFEE, CA 92586 Type: Residential Electrical MENIFEE Date Issued: 12/1512015 PERMIT Site Address: 29179 SWEETBRIAR CT, MENIFEE, CA Parcel Number: 333-640-006 92584 Construction Cost: $10,689.60 Existing Use: Proposed Use: Description of SOLAR TR 31582-1 MENIFEE HILLS Work; 16 MODULES 4.24 KW LOT 92 Owner Contractor LENNAR HOMES OF CA, INC LENNAR HOMES OF CALIFORNIA INC 980 MONTECITO DR#302 25 ENTERPRISE CORONA, CA 92879 ALISO VIEJO, CA 92656 Applicant Phone:9493498269 JEREMIAH ACAYTURRI License Number: 728102 LENNAR HOMES OF CALIFORNIA INC 25 ENTERPRISE ALISO VIEJO, CA 92656 Fee Description Qtv Amount isl Solar, Residential or Small Commercial 1 252.00 Building Permit Issuance 1 27.00 GREEN FEE 1 1.00 SMIP RESIDENTIAL 1 2.00 General Plan Maintenance Fee-Electrical 1 12.60 $294.60 The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and specifications or from preventing builiding operations being carried on thereunder when in violation of the Building Code or of any other ordinance of City of Menifee.Except as otherwise stated,a permit for construction under which no work is commenced within six months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be forfeited. AA_Bldg_Pennit_Template.rpt Page 1 of 1 APPLICATIONBUILDING & SAFETY PERMIT/PLAN CHECK JVlenifee DATE 11/05/2015 PERMIT/PLAN CHECK NUMBER TYPE: [-]COMMERCIAL ❑✓ RESIDENTIAL MULTI-FAMILY ❑MOBILEHOME ❑POOL/SPA ❑SIGN SUBTYPE: ❑✓ ADDITION []ALTERATION ❑DEMOLITION ❑ELECTRICAL [—]MECHANICAL ❑NEW ❑PLUMBING ❑RE-ROOF-NUMBER OF SQUARES DESCRIPTION OF WORK Solar Permit-Plan 3404-4.24 kW/16 PCS Master Solar Plan No.: PMT14-00706 PROJECTADDRESS 29179 SweetbNar Ct, Menifee,CA 92584 ASSESSOR'S PARCEL NUMBER 333-640-006 LOT 92 TRACT 31582-1 PROPERTY OWNER'S NAME Lennar Homes of California., Inc. ADDRESS 980 Montecito Dr.,Suite 302, Corona, CA 92879 PHONE (951)817-3680 EMAIL )eremiah.acayturri@lennar.com APPLICANT NAME Jeremiah Acayturri ADDRESS 980 Montecito Dr.,Suite 302 PHONE (951)817-3680 EMAIL jeremiah.aceyturri@lennar.com CONTRACTOR'S NAME Lennar Homes of California, Inc. OWNER BUILDER? ❑✓ YES❑NO BUSINESS NAME Lennar Homes of California, Inc. ADDRESS 980 Montecito Dr.,Suite 302, Corona,CA 92879 PHONE (951)817-3680 EMAIL Jeremiah.acayturri@lennarcom CONTRACTOR'S STATE LIC NUMBER 728102 LICENSE CLASSIFICATION A&B VALUATION$ $ 10,689.60 L SQ FT APPLICANT'S SIGNATURE 77�- DATE 11/05/2015 CITYSTAFF USE ONLY . '>_.. DEPARTMENT DISTRIBUTION r'� CITYOF MENIFEE BUSINESS LICENSE NUMBER BUILDING PLANNING ENGINEERING FIRE GREEN SMIP INVOICE !(.W pplD AMOUNT AMOUNT "� OCASH OCHECKB OCREDITCARD VISA/MC PLAN CHECK FEES PAIDAMOUNT 0CASH 0CHECK# OCREDITCARD VISA/MC OWNER BUILDER VERIFIED OYES O NO DL NUMBER NOTARIZED LETTER O YES O NO City of Menifee Building&Safety Department 29714 Haun Rd. Menifee, CA 92586 951-672-6777 www.cityofinenifee.us Inspection Request Line 951-246-6213 SYSTEM INFORMATION BUYER ACKNOWLEDGES THAT THE SOLAR MODULES TO BE INSTALLED ITEM OTY MFR. MODEL ON THE ROOF OF THE HOME WILL BE SUBSTANTIALLY IN THE SYSTEM SIZE 4.24 KW LOCATIONS INDICATED BY THE ILLUSTRATION. MODULE 1 16 PCS.1 HYUNDAI I HIS-S265RG.(265W) BUYER: INVERTER 1 16 PCS.1 ENPHASE I M215-60-2LL-S22-IG ROOF TYPE I TILE W/COMPOSITE SHINGLE UNDER ARRAY DATE: CITY ITV OF MEIIIFEI SIB-ARRAY INFORMATION ARRAY IN ARRAY#2 ARRAY#3 BUILDING AND S MOD DTY 16 NA NA BUYER: TILT 23 1 NA' I NA' DATE: VA! AZIMUTH 240° NA' NA' REVIEWED BY 'Approval of these pla is shall approval of,any viola of al 26'ARRAY regulationsandordin T 26'-10'FLASHING I`'-1, jobsite until comgletio i. t — I I e I I h I SOLADECK WIRE TRANSITION BOX I (UNDER ARRAY) PV AC DISCONNECT 1 EXTERIOR-GARAGE I UTILITY METER& « ' MAIN SERVICE PANEL 1 (VERIFIED BY BUILDER) V � i ----1 ---J17 1 y � I I M Brl` NOTE:DIMENSIONS ARE SHOWN IN PLANE OF ROOF PLAN 5 ELEVATION C-R ®� ORIENTATION 3 L #92 ORIGINAL BY: ERIK MAY DATE:15.11.03 MENIFEE HILLS LENNAR: 980 MDNTELITO DRIVE,#302 REVIEWED BY:JIMMY METER DATEAS.II.03 CORONA,CA 92879 REV.# BY DATE DESCRIPTION Vnamasr,6 SOLAR DWG TITLE] I PAGE#: SCALE: SITE LOCATION: Streed INDIVIDUAL 4577 der,CO 80304 2ENI SWEETBRIER COURT BaW3.447030304 PLOT PLAN I I/16'= I'-0' MENIFEE.CA 303.44Z0300 SYSTEM LAYOUT MODULE SPECS AND CALCULATIONS INVERTER SPECS AND CALCULATIONS ITEM NOTE/CALC UNIT DETAIL ITEM NOTE/CALC UNIT DETAIL LOCATION MENIFEE,CA INV. MAKE INVERTER SPEC ENPHASE TEMP.AMBIENT HIGH(TMAX) ASHRAE 2% •C 37 INV. MODEL INVERTER SPEC M215-60-2LL-S22-I6 TEMP.AMBIENT LOW(TMIN) ASHRAE EXTR.MIN PC -2 INV. MAX POWER,(WAC MAX) INVERTER SPEC WATTS(AC) 225 TEMP.MODULE TEST(TESST) MODULE SPEC •C 25 INV. INPUT V.(VOC MAX) INVERTER SPEC VOLTS(OC) 48 TEMP,DELTA LOW(TOELTA) THIN-TTEST •C -27 INV.OUTPUT V.(Vac NOM) INVERTER SPEC VOLTS(AC) 240 MOD. MANUFACTURER MODULE SPEC HYUNDAI INV.OUTPUT FREQUENCY INVERTER SPEC HERTZ 60 MOD. PART NUMBER MODULE SPEC HIS-S265RG INV.OUTPUT CURRENT,IAC INVERTER SPEC AMPS(AC) 0.9 �/ MOD. POWER STC(P) MODULE SPEC WATTS(0C) 265 INV.PHASE QUANTITY INVERTER SPEC PHASE I Il. 1 , MOD. POWER PTC MODULE SPEC WATTS(OC) 238 COMPLIANCE INVERTER SPEC UL1741/IEEE1547 MOD. OPERATING VOLTAGE(VMP) MODULE SPEC VOLTS(OG) 31.30 INV.GROUNDING INVERTER SPEC ISOLATED MOD. OPEN CCT. VOLTAGE(Vac) MODULE SPEC VOLTS(DC) 38.10 INV.CITY,MAX/BRANCH CCT. INV.QTYsc1 CITY I16 MOD. COEFF.VOLT/TEMP(COEF) MODULE SPEC V/•C -0.114 BRANCH CCT.OUTPUT.IMAXBC I(IAC•INV.QTYSC) I AMPS(AC) 14.L0 MOD. MAX VOLTAGE(VMAXMOO) (VOC t(To•COEF)) VOLTS(OC) 3'-5 1/4' INV.QUANTITY.TOTAL I INV.QTYi I OTY 1 16 MOD. OPERATING CURRENT(IMP) MODULE SPEC AMPS(0C) 8.50 TOTAL SYSTEM OUTPUT.IMAXTS I(IAC-INV.OTYT) I AMPS(AC) 1 14.40 MOD. SHORT CCT.CURRENT(ISC) MODULE SPEC AMPS(oC) 9.00 MOD. MAXIMUM CURRENT(TMAX) (ISC•1.25) AMPS(DC) 11.25 MIN.AMPACITY REO'D,PER NEC ([MAX•1.25) AMPS(OC) 14.06 SERIES FUSE RATING,MAX MODULE SPEC AMPS(OC) 15. ELECTRICAL EQUIPMENT SCHEDULE t6 CUnSU KEY QTY MANUFACTURER' MODEL NOTES TRADE 1 16 HYUNDAI HIS-S265RG(265W) PV MODULE SOLAR pro isions( 2 16 ENPHASE M215-60-2LL-S22-IG PV INVERTER SOLAR 3 1 RSTC/SOLADECK 0786-3R5 PV ROOF JUNCTION BOX.NEMA 3R SOLAR set of appi 4 1 CUTLER-HAMMER DG221URB PV AC DISCONNECT.NEMA 3R,240V.30A SOLAR 5 1 ENPHASE ENVOY PV DATA MONITOR.120V SOLAR 6 1 TBD TBD 120V DEDICATED RECEPTACLE FOR ENVOY PV DATA MONITOR SOLAR 7 1 TBD TBD CAT5 PORT FOR SOLAR PV INTERNET CONNECTION TO HOME NETWORK BDX SOLAR 8 NOTE CUTLER-HAMMER TBD PV BRANCH CIRCUIT BREAKERS:I X 15A-IP(ENVOY) SOLAR' 9 NOTE CUTLER-HAMMER TBD PV BREAKER, I x 20A-2P,LOCATE AT OPPOSITE END OF BUS FROM MAIN BREAKER SOLAR 10 TBD TBD SERVICE PANEL,MIN. 125A BUS BLDR.ELEC. II TBD TBD UTILITY METER,IPH,1201240V,200A BLDR.ELEC. 12 1 I 1 TBD I TBD I GROUNDING ELECTRODE UFER BLDR.ELEC. CONDUCTOR SIZING CALCULATIONS INTERCONNECTION CALCULATIONS D CONDITION OF USE(COU): (AMPACITY •TEMP.DERATE•FILL OERATE)Vs.REQ'D([MAX) ITEM UNIT PANEL 2)TERMINALS(TERM): AMPACITY AT TERMINALS. VS.REQ'D,(IMAX• 1.25) PANEL MFR. CUTLER-HAMMER KEY SIZE CU/AL INSULATION CALC. AMPACITY W/0 TEMP. FILL RESULT WREO'DOCDBUS RATING AMPS 200 TYPE DERATES DERATE DERATE (A) MAIN DISCONNECT AMPS 200 A #12 CU THWN-2 COU 30 076 I.0 22.80 ALLOWED PV PER NEC AMPS 40 TERM 25 25 PV OCPD DEVICE USED AMPS 20 B #10 CU NM-B COU 40 0.91 I.0 36.40 TERM 35 35#10 LU NM-B COU 40 0.91 1.0 36.40 TERM 35 35 CONDUCTOR SCHEDULE KEY CONDUCTORS I CU/AL TYPE LOCATION TRADE A I-#12 ENGAGE CABLE,1-#6G,FREE AIR CU TC-ER ARRAY SOLAR B 3-#10.I-#10 EGC I CU NM-B(ROMEX) INTERIOR SOLAR C 1 3-#10,L#10 EGG I CU I NM-B(ROMEX) INTERIOR SOLAR D 1 CATSE,ETHERNET CABLE I CU I CATSE INTERIOR I SOLAR 5 6 II 7 � o e I M — SEE NOTE 15 10 D o Lv 3 'N — ° GI A B C =12 I I ROOF EXTERIGR-GARAGE ELECTRICAL DIAGRAM 4.24 KW LOT#92 ORIGINAL BY: ERIK MAY DATE:15.11:03 MENIFEE HILLS LENNAR: 980 I DRIVE.#302 REVIEWED BY:JIMMY METER DATE:15.11.03 CORONNA,A.C CA A 92879 REV.# BY DATE DESCRIPTION namaste SOLAR DWG TITLE: PAGE*: I SCALE: SITE LOCATION: 4671 B=dAay Street __ INDIVIDUAL- 29179 SWEETBRIER COURT Boulder,CO ao 0 PLOT PLAN 2 NTS MENIFEE,CA '�T�� ELECTRICAL STRUCTURAL NOTES: SOLAR CONTRACTOR- D ALL PV ROOF ATTACHMENTS WILL BE SPACED ALONG MODULE RACKING RAILS AT NOT GREATER THAN 48'O.C. 2)ALL PV ROOF ATTACHMENTS WILL BE STAGGERED BY ROW AMONGST THE ROOF FRAMING MEMBERS, TO MAXIMUM EXTENT POSSIBLE. 3)ROOF PENETRATIONS ASSOCIATED WITH SOLAR RACKING WILL BE SEALED WITH AN APPROVED SEALANT. 4)SOLADECK WIRE TRANSITION BOX WILL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS. IT WILL BE FLASHED AND SEALED. 5)PV ARRAY WILL BE A MINIMUM OF 3'ABOVE THE COMPOSITE SHINGLE ROOF SURFACE. 6)THE UNIRAC SOLARMOUNT RACKING SYSTEM AND SOLAR PV ARRAY WILL BE INSTALLED ACCORDING TO THE UNIRAC SOLARMOUNT CODE-COMPLIANT INSTALLATION w ) MANUAL.VERSION 227.3.PUB 140113-ICC,JAN'UARY 2014. H 7)UNIRAC TOP CLAMPS REQUIRE A ONE INCH(19 SPACE BETWEEN PV MODULES. SOLARMOUNT RAILS MUST EXTEND A MINIMUM OF TWO INCHES(P)BEYOND THE EDGE OF THE PV ARRAY/SUB-ARRAY. 8)UNIRAC SOLARMOUNT REQUIRES THAT A THERMAL EXPANSION GAP BE INSTALLED FOR ANY RAIL LENGTH OF GREATER THAN 40'. ROOFING CONTRACTOR- U DISTANCE BETWEEN ARRAY EDGE AND TRANSITION FLASHING(COMPOSITION TO TILE)WILL BE A MINIMUM OF 3'. 2)26 GAUGE INTERLOCKING FLASHING'SIDEWALL'TO BE INSTALLED ALONG THE LENGTH OF THE PV ARRAY AT ROOFING MATERIAL TRANSITION. IT SHALL BE APROVED PRIOR TO PV SYSTEM INSTALLATION. ic114, 3)PEEL-N-STICK BASE TO BE INSTALLED ONE FOOT(0 OR MORE BEYOND THE EDGE OF THE COMPOSITION SHINGLE,DOWN TO THE ROOF EAVE.PEEL-N-STICK BASE TO BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS. 4)AREAS UNDER EACH PV ARRAY SHALL BE ROOFED WITH COMPOSITION SHINGLE.COMPOSITION SHINGLE SHALL RUN FROM ABOVE THE PV ARRAY TO THE ROOF EAVE. 5)TILE INSTALLED BELOW THE ARRAY TO BE INSTALLED ABOVE THE COMPOSITION ROOF PER ROOFER SPECIFICATIONS, 6)BIRDSTOP WILL BE INSTALLED AT THE UPPERMOST TRANSITION FROM TILE TO COMPOSITION SHINGLE. BIRDSTOP TO BE SPECIFIED BY ROOFER PRIOR TO INSTALLATION. be a p( h federal, A plans mi ELECTRICAL NOTES: GENERAL- U ALL PV EQUIPMENT WILL BE TESTED AND LISTED FOR ITS USE BY A NATIONALLY RECOGNIZED TESTING LABORATORY(NRTL). 2)THE GROUNDING OF THE PHOTOVOLTAIC SYSTEM SHALL COMPLY WITH THE APPLICABLE VERSION OF THE NEC/CEC. 3)ALL GROUNDING ELECTRODE CONDUCTORS WILL BE INSTALLED IN A CONTINUOUS LENGTH EXCEPT WHERE SPLICED BY AN IRREVERSIBLE CONNECTOR OR EXOTHERMIC WELD. 4)NON-CURRENT CARRYING METAL PARTS SHALL BE CHECKED FOR PROPER GROUNDING,NOTING THAT TERMINAL LUGS BOLTED ON AN ENCLOSURE'S FINISHED SURFACE MAY BE ELECTRICALLY INSULATED BECAUSE OF PAINT/FINISH. PAINT/FINISH AT POINT OF CONTACT SHALL BE PROPERLY REMOVED. 5)ROOF PENETRATIONS WILL BE COMPLETED AND SEALED PER APPLICABLE CODE. 6)ALL CONDUCTORS WILL HAVE A 90-C RATING TO ENSURE CODE COMPLIANCE. SOLAR CONTRACTOR- 7)MODULE CERTIFICATIONS WILL INCLUDE UL1703,IEC61646,IEC61730. 8)CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS. 9)RACEWAY POINT OF PENETRATION FROM EXTERIOR TO INTERIOR WILL BE SEALED TO PREVENT INGRESS OF WATER AND INSECTS, 10)DC WIRING IS LIMITED TO PV ARRAY FOOTPRINT W/ENPHASE MICRO-INVERTER SYSTEM. IU MODULE AND ENPHASE WIRING SMALL BE LOCATED AND SECURED UNDER THE ARRAY USING SUITABLE WIRING CLIPS.WIRING SHALL NOT MAKE CONTACT WITH THE ROOF SURFACE AND SHALL BE MANAGED IN A WORKMAN-LIKE MANNER. 12)EQUIPMENT GROUNDING CONDUCTORS WILL BE SIZED IN ACCORDANCE WITH NEC TABLE 250.122. 13)CONDUCTOR TERMINATIONS WILL BE TORQUED PER DEVICE LISTING,OR MANUFACTURER'S RECOMMENDATIONS. 14)A PV AGGREGATION PANEL(SUB PANEL)WILL NOT BE INCLUDED FOR SYSTEMS WITH ONE BRANCH CIRCUIT. 15)A DEDICATED 120V BRANCH CIRCUIT IS REQUIRED IN MASTER CLOSET(OR EQUIVALENT)FOR ENPHASE ENVOY MONITOR. SIGNAGE- 16)PV SYSTEMS SHALL BE CLEARLY MARKED IN ACCORDANCE WITH NEC ARTICLE 690 AND OTHER APPLICABLE STATE AND LOCAL CODES. 17)ALL SAFETY MARKING/PLACARDS SHALL BE PERMANENTLY ATTACHED BY ADHESIVE OR OTHER MECHANICAL MEANS. 18)MARKING/PLACARDS WILL BE METAL OR PLASTIC.WITH ENGRAVED OR MACHINE PRINTED LETTERING.BACKGROUND WILL BE RED WITH WHITE CAPITAL LETTERING OF MINIMUM HEIGHT t. 19)ALL WIRING/RACEWAYS/JUNCTION BOXES WILL BE MARKED'PHOTOVOLTAIC POWER SOURCE:OR EQUIVALENT;WIRING/RACEWAYS SHALL BE MARKED EVERY 10'. BUILDER ELECTRICAL AND SOLAR CONTRACTORS- 20)INSTALLATION SHALL BE COMPLETED IN A NEAT AND WORKMAN-LIKE MANNER, 21)SPACE REQUIREMENTS FOR ALL ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110.26. LENNAR: ORIGINAL BY: ERIK MAY DATE:15.11.03 MENIFEE HILLS O DRIVE.#302 REVIEWED BV:JIMMY METER DATE:15.11.03 CORONNA,A.MON C CA 9 CORONA. 92879 REV.# BY DATE I DESCRIPTION namasbe SOLAR DWG TITLE: PAGE#: SCALE: SITE LOCATION: INDIVIDUAL-- - - 45]1 BraaBway Street PLOT PLAN 3 NTS --MENU SWEETBRIER COURT BWIGa4 7. 30304 NOTES MENIFEE.LA 303.447.0300 CAUTION: POWER TO THIS BUILDING IS SUPPLIED BY THE ENT UTILITY AND A SOLAR PV SYSTEM. DISCONNECTS ARE LOCATED AS SHOWN. � A + for,or an e or city Te kept on e aaLLORx wRe iP6VBITICN BOM IIMEP IAP<VI NKUIYB.E T EXiEPItli-LLINLE UilLIW M M a MIN aE.MP I L MRIFIEDBYBUILB ) SERVICE BY QUALIFIED PERSONNEL ONLY CONTACT: SUNSTREET ENERGY GROUP I-B77-SLR-POWR PV POWER SOURCE - AC SPECS AC OPERATING VOLTAGE: 240 V AC OPERATING CURRENT: 14.4 A NOTE: SEE MASTER SET FOR ADDITIONAL PLACARD INFORMATION : ORIGINAL BY: ERIK MAY DATE:15.11.03 MENIFEE HILLS LENNAR 980 MONTECI 92 DRIVE,#302 REVIEWED BY:JIMMY METER DATE:15.11.03 - CORONA,CA 879 REV.# BY DATE DESCRIPTION Vnam(3sbc MAN DWG TITLE: PAGE#: SCALE: SITE LOCATION: - - -- - — -- 4571 Broadway SVeet - PLOTINDIV OVAL MENIF SWEETBRIER COURT BwIdw.CO 80304 PLOT PLAN A NTS MENIFEE,CA PLACARDS 303.447.0300