Loading...
PMT15-03573 City of Menifee Permit No.: PMT15-03573 29714 HAUN RD. �CCEL/? MENIFEE, CA 92586 Type: Residential Electrical MENIFEE Date Issued: 1 211 512 01 5 PERMIT Site Address: 29156 ABELIA GLEN ST, MENIFEE, CA Parcel Number: 333-632-014 92584 Construction Cost: $14,593.40 Existing Use: Proposed Use: Description of SOLAR TR 31582-1 MENIFEE HILLS Work: 14 MODULES 3.71 KW LOT 67 Owner Contractor LENNAR HOMES OF CA, INC LENNAR HOMES OF CALIFORNIA INC 980 MONTECITO DR#302 25 ENTERPRISE CORONA, CA 92879 ALISO VIEJO, CA 92656 Applicant Phone: 9493498269 JEREMIAH ACAYTURRI License Number:728102 LENNAR HOMES OF CALIFORNIA INC 25 ENTERPRISE ALISO VIEJO, CA 92656 Fee Description gyt Amount M Solar, Residential or Small Commercial 1 252.00 Building Permit Issuance 1 27.00 GREEN FEE 1 1.00 SMIP RESIDENTIAL 1 2.00 General Plan Maintenance Fee-Electrical 1 12.60 $294.60 The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and specifications or from preventing builiding operations being carried on thereunder when in violation of the Building Code or of any other ordinance of City of Menifee.Except as otherwise stated,a permit for construction under which no work is commenced within six months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be forfeited. AA_Blog_Pemnit_Template.rpt Page 1 of 1 BUILDING & SAFETY PERMIT/PLAN CHECK APPLICATION Menifee DATE 11/05/2015 PERMIT/PLAN CHECK NUMBER /�5 V� ✓ TYPE: [I COMMERCIAL Z RESIDENTIAL ❑MULTI-FAMILY ❑MOBILEHOME ❑POOL/SPA [-]SIGN SUBTYPE: ❑✓ ADDITION []ALTERATION []DEMOLITION ❑ELECTRICAL ❑MECHANICAL [:]NEW ❑PLUMBING ❑RE-ROOF-NUMBER OF SQUARES DESCRIPTION OF WORK Solar Permit-Plan 3105-3.71 kW/14 PCS Master Solar Plan No.: PMT14-00706 PROJECTADDRESS 29156 A6elia Glen Street ASSESSOR'S PARCEL NUMBER 333-632-014 LOT 67 TRACT 31582-1 PROPERTY OWNER'S NAME Lennar Homes of California, Inc. ADDRESS 980 Montecito Dr., Suite 302 PHONE (951)817-3680 EMAIL leremiah.acayturri@lennar.com APPLICANT NAME Jeremiah Acayturri ADDRESS 980 Montecito Dr.,Suite 302 PHONE (951)817-3680 EMAIL jeremlah.acayturri@lennar.com CONTRACTOR'S NAME Lennar Homes of California, Inc. OWNER BURDER? ❑✓ YES❑NO BUSINESS NAME Lennar Homes of California, Inc. ADDRESS 980 Montecito Dr.,Suite 302 PHONE (951)817-3680 EMAIL Jeremiah.acayturri@lennar.com IV V 06 k'04, CONTRACTOR'S STATE LIC NUMBER 728102 LICENSE CLASSIFICATION A&B VALUATION$ $14,593.40 LSQFT ��-APPLICANT'S SIGNATURE DATE 11/05/2015 CITYSTAFF USE ONLY DEPARTMENT DISTRIBUTION / CITY OF MENIFEE BUSINESS LICENSE NUMBER BUILDING PLANNING ENGINEERING FIRE I GREEN SMIP INVOICE (pO PAIDAMOUNT AMOUNT 0 CASH O CHECK# OCREDITCARD VISA/MC PLAN CHECK FEES PAIDAMOUNT oCASH ^CHECK# OCREDITCARD VISA/MC OWNER BUILDER VERIFIED OYES 0 No DL NUMBER NOTARIZED LETTER 0 YES O NO City of Menifee Building&Safety Department 29714 Houn Rd. Menifee, CA 91586 951-672-6777 www.cityofinenifee.us Inspection Request Line 951-246-6213 SYSTEM INFORMATION BUYER ACKNOWLEDGES THAT THE SOLAR MODULES TO BE INSTALLED ITEM 1 MFR. MODEL ON THE ROOF OF THE HOME WILL BE SUBSTANTIALLY IN THE SYSTEM SIZE 1 .71 KW I LOCATIONS INDICATED BY THE ILLUSTRATION. CITY OF M NIFI MODULE 14 PCS. HYUNDAI HiS-S255RG(265W) BUYER: INVERTER 1 14 PCS.I ENPHASE I M215-60-21 -S22-IG RUII nING ND ROOF TYPE TILE W/COMPOSITE SHINGLE UNDER ARRAY DATE: SUB-ARRAY INFORMATION City of Menifea ARRAY#1 ARRAY#2 1 ARRAV#3 Building Dept PLAN APPR VA MOD OTY 10 2 2 BUYER: TILT 23' 23• 23° AZIMUTH 140' 230° 50° NOV 13 LvLJ DATE: — REVIEWED 16f Receiw., 'Arlurovalof these pans shi aporoval of,any viol ion of regulations and ordin nre:- iobsite until completi s;, 22'-9'ARRAY 3' 23'-7-FLASHING -————————_ _._— � I I I f I u rz _ az N aLL i SOLADECK WIRE + TRANSITION BOX (UNDER ARRAY) L J - PV DISCONNECT -n I EXTEE RIOR-GARAGE �6p UTILITY METER B L — MAIN SERVICE PANEL � _J (VERIFIED BY BUILDER) NOTE:DIMENSIONS ARE SHOWN IN PLANE OF ROOF ^, PLAN 4 ELEVATION A67 ORI N A ION 0 6 ORIGINAL BY: ERIK MAY I DATE:15.11. LENNAR: 03 MENIFEE HILLS REVIEWED BY:JIMMY METER DATE:15.11.03 980 MONTECITO DRIVE,#302 - CORONA.CA 92879 REV.# BY DATE DESCRIPTION ;Pn imast;6 SOLAR _ _DWG TITLE__- PAGE#: SCALE: __ SITE LOCATION: — - — 4571 BmadmY S"a INDIVIDUAL 29156 ABELIA GLEN STREET BaNtlaf,CO 80304 PLOT PLAN 1 1/16'=1'-0' MENIFEE,CA 307A47.0300 SYSTEM LAYOUT MODULE SPECS AND CALCULATIONS INVERTER SPECS AND CALCULATIONS ITEM NOTE/CALC UNIT DETAIL ITEM NOTE/CALC UNIT DETAIL LOCATION MENIFEE,CA INV. MAKE INVERTER SPEC ENPHASE TEMP,AMBIENT HIGH(TMAX) ASHRAE 2% °C 37 INV. MODEL INVERTER SPEC 1215-60-21-L-S22-IG TEMP.AMBIENT LOW(THIN) ASHRAE EXTR.MIN •C -2 INV. MAX POWER,(WAC MAX) INVERTER SPEC WATTS(AC) 225 TEMP,MODULE TEST(TTEST) MODULE SPEC •C 25 INV. INPUT V.(VOC MAX) INVERTER SPEC VOLTS CDC) 48 DE TEMP.DELTA LOW(TDELTA) THIN-TTEST °C -27 INV.OUTPUT V,(VAC NOM) INVERTER SPEC VOLTS CAC) 240 MOD. MANUFACTURER MODULE SPEC HYUNDAI INV,OUTPUT FREQUENCY INVERTER SPEC HERTZ 60 MOD.PART NUMBER MODULE SPEC HIS-S265RG INV.OUTPUT CURRENT.IAC INVERTER SPEC AMPS(AC) 0.9 MOD.POWER STC(P) MODULE SPEC WATTS(oc) 265 INV.PHASE QUANTITY INVERTER SPEC PHASE 1 MOD.POWER PTC MODULE SPEC WATTS(DC) 238 COMPLIANCE INVERTER SPEC UL1741/IEEEI547 MOD, OPERATING VOLTAGE(VMP) MODULE SPEC VOLTS(DC) 31.30 INV. GROUNDING INVERTER SPEC ISOLATED MOD.OPEN CCT. VOLTAGE(VOO) MODULE SPEC VOLTS(DC) 38.10 INV.OTY.MAX/BRANCH CCT. 1 INV.QTYBO OTY 16 MOD.COEFF.VOLT/TEMP(COEF) MODULE SPEC V/°C -0.114 BRANCH CCT.OUTPUT,IMAXSC I (IAC•INV.OTYBC) 11AMPS(AC) 14.40 MOD. MAX VOLTAGE(VMAXNOD) (VOC r(TO•COEF)) VOLTS(DC) 3'-5 1/4- INV.QUANTITY,TOTAL I INV.QTYT I CITY I16 MOD.OPERATING CURRENT(IMP) MODULE SPEC AMPS CDC) 8.50 TOTAL SYSTEM OUTPUT, IMAXTS I (IAC•INV.OTYT) I AMPS(Ae) 1 14.40 MOD.SHORT CCT.CURRENT(ISU MODULE SPEC AMPS(DC) 9.00 MOD. MAXIMUM CURRENT(TMAX) Osc•1.25) AMPS(DC) 11.25 MIN.AMPACITY REO'D,PER NEC (IMAX-1.25) AMPS Coe) 14.06 of 6e cc n*m SERIES FUSE RATING,MAX MODULE SPEC AMPS(00) 1 15 /pr aft ELECTRICAL EQUIPMENT SCHEDULE KEY CITY MANUFACTURER MODEL NOTES TRADE s set ippm 1 16 HYUNDAI HIS-S265RG(265W) PV MODULE SOLAR 2 16 ENPHASE M215-60-2LL-S22-IG PV INVERTER SOLAR 3 3 RSTC/SOLADECK 0786-3R5 PV ROOF JUNCTION BOX,NEMA 3R SOLAR 4 1 CUTLER-HAMMER DG221URB PV AC DISCONNECT,NEMA 3R,240V.30A SOLAR 5 1 ENPHASE ENVOY PV DATA MONITOR,120V SOLAR 6 1 TBD TBD 120V DEDICATED RECEPTACLE FOR ENVOY PV DATA MONITOR SOLAR 7 1 TBD TBD CATS PORT FOR SOLAR PV INTERNET CONNECTION TO HOME NETWORK BOX SOLAR 8 NOTE CUTLER-HAMMER TBD PV BRANCH CIRCUIT BREAKERS; I x ISA-IP(ENVOY) SOLAR 9 NOTE CUTLER-HAMMER TBD PV BREAKER,I X 20A-2P,LOCATE AT OPPOSITE END OF BUS FROM MAIN BREAKER SOLAR 10 I TBD TBD SERVICE PANEL.MIN. 125A BUS BBLDR ELEC. 1 LDR.E TBD TBD UTILITY METER,]PH. 120/24OV.200A LEC. 12 I TBD TBD GROUNDING ELECTRODE UFER I BLDR.ELEC. CONDUCTOR SIZING CALCULATIONS INTERCONNECTION CALCULATIONS U CONDITION OF USE(CCU): (AMPACITY-TEMP.DERATE •FILL DERATE)vs.REQ'D(IMAX) ITEM UNIT PANEL 2)TERMINALS(TERM): AMPACITY AT TERMINALS.VB.REO'D,(IMAX• 1.25) PANEL MFR. CUTLER-HAMMER KEY SIZE CU/AL INSULATION CALC. AMPACITY W/O TEMP. FILL RESULT REO'D OCD BUS RATING AMPS 200 TYPE DERATES DERATE DERATE (A) (A) USED(A) MAIN DISCONNECT AMPS 200 A #12 CU THWN-2 COU 30 0.76 1.0 22.80 14.40 ALLOWED PV PER NEC AMPS 40 TERM 25 25 I8.00 20 PV OCPD DEVICE USED AMPS 1 20 B #10 1 CU 1 NM-B COU 40 0.91 1.0 36.40 14.40 TERM 35 35 IBOO 20 c #10 1 CU NM-B COU 40 0.91 1.0 36.40 14.40 TERM 35 35 18.00 20 CONDUCTOR SCHEDULE KEY CONDUCTORS CU/AL TYPE LOCATION TRADE A I-#12 ENGAGE CABLE.I-#6G.FREE AIR I CU I TC-ER I ARRAY SOLAR B 3-410. 1-#10 EGC I CU I NM-B(ROMEX) INTERIOR SOLAR C 3-#10, 1-#10 EGG I CU I NM-B(ROMEX) INTERIOR SOLAR D I CAT5E.ETHERNET CABLE I CU I CAT5E I INTERIOR I SOLAR O 5 6 II 3 7 • o m O - m G SEE NOTE 15 10 O 15© G O 20AN �N G G� C x 1 I ROOF GARAGE ELECTRICAL DIAGRAM L"T IW LENNAR: ORIGINAL BY: ERIK MAY I DATE:15.11.03 MENIFEE HILLS 980 REVIEWED BY:JIMMY METER DATE:15.11.03 CORONNA,CA A.CA 92 DRIVE,#302 879 REV.# BY GATE DESCRIPTION •, namast;e SOLAR DWG TITLE: PAGE#: SCALE: SITE LOCATION: _ _ _4571 Broadway SVee( ---INDIVIDUAL - -- - 29156 ABELIA GLEN STREET _ - Boulder,C080304 PLOT PLAN 2 NTS MENIFEE,CA 303A47.0300 ELECTRICAL STRUCTURAL NOTES: SOLAR CONTRACTOR- D ALL PV ROOF ATTACHMENTS WILL BE SPACED ALONG MODULE RACKING RAILS AT NOT GREATER THAN 40'O.C. 2)ALL PV ROOF ATTACHMENTS WILL BE STAGGERED BY ROW AMONGST THE ROOF FRAMING MEMBERS,TO MAXIMUM EXTENT POSSIBLE. 3)ROOF PENETRATIONS ASSOCIATED WITH SOLAR RACKING WILL BE SEALED WITH AN APPROVED SEALANT. ��� 4)SOLADECK WIRE TRANSITION BOX WILL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS. IT WILL BE FLASHED AND SEALED. 5)PV ARRAY WILL BE A MINIMUM OF 3'ABOVE THE COMPOSITE SHINGLE ROOF SURFACE. 6)THE UNIRAC SOLARMOUNT RACKING SYSTEM AND SOLAR PV ARRAY WILL BE INSTALLED ACCORDING TO THE UNIRAC SOLARMOUNT CODECOMPLIANT INSTALLATION MANUAL.VERSION 227.3.PUB 140113-ILL.JANUARY 2014. 7)UNIRAC TOP CLAMPS REQUIRE A ONE INCH(1')SPACE BETWEEN PV MODULES.SOLARMOUNT RAILS MUST EXTEND A MINIMUM OF TWO INCHES(29 BEYOND THE EDGE OF THE PV ARRAY/SUB-ARRAY. 1+' 8)UNIRAC SOLARMOUNT REQUIRES THAT A THERMAL EXPANSION GAP BE INSTALLED FOR ANY RAIL LENGTH OF GREATER THAN 40'. ROOFING CONTRACTOR- U DISTANCE BETWEEN ARRAY EDGE AND TRANSITION FLASHING(COMPOSITION TO TILE)WILL BE A MINIMUM OF 3% 2)26 GAUGE INTERLOCKING FLASHING'SIDEWALL'TO BE INSTALLED ALONG THE LENGTH OF THE PV ARRAY AT ROOFING MATERIAL TRANSITION. IT SHALL BE APROVED PRIOR TO PV SYSTEM INSTALLATION. 3)PEEL-N-STICK BASE TO BE INSTALLED ONE FOOT(0 OR MORE BEYOND THE EDGE OF THE COMPOSITION SHINGLE,DOWN TO THE ROOF EAVE,PEEL-N-STICK BASE TO BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS. 4)AREAS UNDER EACH PV ARRAY SHALL BE ROOFED WITH COMPOSITION SHINGLE.COMPOSITION SHINGLE SHALL RUN FROM ABOVE THE PV ARRAY TO THE ROOF EAVE. be a Unnit ft 5)TILE INSTALLED BELOW THE ARRAY TO BE INSTALLED ABOVE THE COMPOSITION ROOF PER ROOFER SPECIFICATIONS. 6)BIRDSTOP WILL BE INSTALLED AT THE UPPERMOST TRANSITION FROM TILE TO COMPOSITION SHINGLE.BIRDSTOP TO BE SPECIFIED BY ROOFER PRIOR TO eder if,state INSTALLATION. Glans nustbel ELECTRICAL NOTES: GENERAL- I)ALL PV EQUIPMENT WILL BE TESTED AND LISTED FOR ITS USE BY A NATIONALLY RECOGNIZED TESTING LABORATORY(NI 2)THE GROUNDING OF THE PHOTOVOLTAIC SYSTEM SHALL COMPLY WITH THE APPLICABLE VERSION OF THE NEC/CEC. 3)ALL GROUNDING ELECTRODE CONDUCTORS WILL BE INSTALLED IN A CONTINUOUS LENGTH EXCEPT WHERE SPLICED BY AN IRREVERSIBLE CONNECTOR OR EXOTHERMIC WELD. 4)NON-CURRENT CARRYING METAL PARTS SMALL BE CHECKED FOR PROPER GROUNDING,NOTING THAT TERMINAL LUGS BOLTED ON AN ENCLOSURE'S FINISHED SURFACE MAY BE ELECTRICALLY INSULATED BECAUSE OF PAINT/FINISH. PAINT/FINISH AT POINT OF CONTACT SHALL BE PROPERLY REMOVED. 5)ROOF PENETRATIONS WILL BE COMPLETED AND SEALED PER APPLICABLE CODE. 6)ALL CONDUCTORS WILL HAVE A 90°C RATING TO ENSURE CODE COMPLIANCE. SOLAR CONTRACTOR- 7)MODULE CERTIFICATIONS WILL INCLUDE U1_1703,IEC61646.IEC61730. 8)CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS. 9)RACEWAY POINT OF PENETRATION FROM EXTERIOR TO INTERIOR WILL BE SEALED TO PREVENT INGRESS OF WATER AND INSECTS. 10)DC WIRING IS LIMITED TO PV ARRAY FOOTPRINT W/ENPHASE MICRO-INVERTER SYSTEM. 10 MODULE AND ENPHASE WIRING SHALL BE LOCATED AND SECURED UNDER THE ARRAY USING SUITABLE WIRING CLIPS.WIRING SHALL NOT MAKE CONTACT WITH THE ROOF SURFACE AND SMALL BE MANAGED IN A WORKMAN-LIKE MANNER. 12)EQUIPMENT GROUNDING CONDUCTORS WILL BE SIZED IN ACCORDANCE WITH NEC TABLE 250.122. 13)CONDUCTOR TERMINATIONS WILL BE TORQUED PER DEVICE LISTING,OR MANUFACTURER'S RECOMMENDATIONS. 14)A PV AGGREGATION PANEL(SUB PANEL)WILL NOT BE INCLUDED FOR SYSTEMS WITH ONE BRANCH CIRCUIT. 15)A DEDICATED 120V BRANCH CIRCUIT IS REQUIRED IN MASTER CLOSET(OR EQUIVALENT)FOR ENPHASE ENVOY MONITOR. SIG14AGE- 16)PV SYSTEMS SHALL BE CLEARLY MARKED IN ACCORDANCE WITH NEC ARTICLE 690 AND OTHER APPLICABLE STATE AND LOCAL CODES. 17)ALL SAFETY MARKING/PLACARDS SHALL BE PERMANENTLY ATTACHED BY ADHESIVE OR OTHER MECHANICAL MEANS. 18)MARKING/PLACARDS WILL BE METAL OR PLASTIC WITH ENGRAVED OR MACHINE PRINTED LETTERING. BACKGROUND WILL BE RED WITH WHITE CAPITAL LETTERING OF MINIMUM HEIGHT j'. 19)ALL WIRING/RACEWAYS/JUNCTION BOXES WILL BE MARKED'PHOTOVOLTAIC POWER SOURCE.'OR EQUIVALENT:WIRING/RACEWAYS SHALL BE MARKED EVERY 10'. BUILDER ELECTRICAL AND SOLAR CONTRACTORS- 20)INSTALLATION SHALL BE COMPLETED IN A NEAT AND WORKMAN-LIKE MANNER, 20 SPACE REQUIREMENTS FOR ALL ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110.26. LENNAR: ORIGINAL BY: ERIK MAY DATE:15.11.03 MENIFEE HILLS 980 REVIEWED BY:JIMMY METER DATE:15.11.03 CORONA.NAI DRIVE.#302,C CA A 92879 REV.# BY DATE DESCRIPTION d namaste wuv DWG TITLE: PAGE#: I SCALE: SITE LOCATION: 4571 B dway Steel INDIVIDUAL 29156 ABELIA BEEN STREET - Boulcu,,CO 803N PLOT PLAN 3 NITS MENIFEE,CA 303.447.0300 NOTES CAUTION: POWER TO THIS BUILDING IS SUPPLIED BY THE UTILITY AND A SOLAR PV SYSTEM. DISCONNECTS ARE LOCATED AS SHOWN. MTE )ran ity 4 on the iR S�LKECR WIPE 1H � nreA,,R umn Y)rl W K PIYO GMAA `i EPIEPtOP-L]R1GE ^ VILLITv 1E1ER 0 MRIN YPNLE PMfL (VERIFIED BY BNLMRI SERVICE BY QUALIFIED PERSONNEL ONLY CONTACT: SUNSTREET ENERGY GROUP 1-877-SLR-POWR PV POWER SOURCE - AC SPECS AC OPERATING VOLTAGE: 240 V AC OPERATING CURRENT: 14.4 A NOTE: SEE MASTER SET FOR ADDITIONAL PLACARD INFORMATION ORIGINAL BY: ERIK MAY I DATE:I .11. 980 MONTELITO DRIVE,#302 03 MENIFEE HILLS LENNAR: REVIEWED BY:JIMMY METER DATE:15.11.03 CORONA,CA 92879 REV.# BY DATE DESCRIPTION VnamastI6 soL�e _ DWG TITLE: __ PAGE : SCALE'. SITE LOCATION: _ _ —— _ _ __ _._— - — -- 4571&oed"YSV t INDIVIDUAL Boulder,CO 80304 PLOT PLAN A NTS MENIF ABELIA GLEN STREET 303447�W PLACARDS MENIFEE.CA