Loading...
PMT15-03484 City of Menifee Permit No.: PMT15-03484 29714 HAUN RD. Type: Residential Addition <A-CCEL/? MENIFEE,CA 92586 MENIFEE Date Issued: 0211712016 PERMIT Site Address: 33766 DAILY RD, MENIFEE, CA 92584 Parcel Number: 384-040-011 Construction Cost: $9,998.64 Existing Use: 1 &2 Family Residence Proposed Use: Description of INSTALLATION OF 648 SO FT GREENHOUSE, NO ELECTRICAL, NO PLUMBING Work: Owner Contractor TIHOMIR TKALEC , 33766 DAILY RD Applicant License Number: TIHOMIR TKALEC 33766 DAILY RD MENIFEE,CA Phone: 9513170806 Fee Description City, Amount($1 Building Permit Issuance 1 27.00 Inspections not specified 258 258.14 Additional Plan Review Building 74 74.18 GREEN FEE 1 1.00 SMIP RESIDENTIAL 1 2.00 New Construction Permit Fee 1 45.99 General Plan Maintenance Fee-New 1 2.30 Construction $410.61 The issuance of this permit shall not prevent the building official from thereafter requiring the correction of enrors in the plans and specifications or from preventing builiding operations being carded on thereunder when in violation of the Building Code or of any other ordinance of City of Menifee.Except as otherwise staled,a permit for construction under which no work is commenced within six months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be forfeited. AA_Bldg_Permit Template.rpt Page 1 of 1 City Of Menifee LICENSED DECLARATION ❑ lam exempt from Iicensure under the Contractors'State License Law for the I hereby affirm under penalty or perjury that I am licensed under provisions of following reason: Chapter 9(commencing with section 7000)of Division 3 of the Business and By my signature below I acknowledge that, except for my personal residence in Professions Code and my license is in full force and effect. which I must have resided for at least one year prior to completion of License Class License No. improvements covered by this permit, I cannot legally sell a structure that I have Expires Signature built as an owner-building if it has not been constructed in its entirety by licensed contractors. I understand that a copy of the applicable law, Section 7044 of the WORKERS'COMPENSATION DECLARATION Business and Professions Code,is available upon request when this application is submitted or at the following Web site: ❑ 1 hereby affirm under penalty of perjury one of the following declarations: htto:/lwww.leainfo.ca.aov/calaw.html. I have and will maintain a certificate of consent of self-insure for workers' compensation,issued by the Director of Industrial Relations as provided for by Date Section 3700 of the Labor Code, for the performance of work for which this permit is issued. Property Owner or Authorized Agent Policy# )it By my Signature below, I certify to each of the following: I am the property ❑ 1 have and will maintain workers' compensation insurance, as required by owner or authorized to act on the property owner's behalf. I have read this section 3700 of the Labor Code, for the performance of the work for which this application and the information I have provided is correct. I agree to comply permit is issued.My workers'compensation insurance carrier and policy number are: with all applicable city and county ordinances and state laws relating to building construction.I authorize representatives of this city or county to enter the above- Carrier identified p for the inspection purposes. Policy# Expires Q� Date 7 Pry Owner or Authorized Agent (This section need not be completed if the permit is for City Business License# one-hundred dollars($100)or less) HAZARDOUS MATERIAL DECLARATION ❑ 1 cartify that in the performance of the work for which this permit is issued,I shall not employ any persons In any manner so as to become subject to the Will the applicant or future building occupant handle hazardous material or a workers'compensation laws of California, and agree that if I should become mixture containing a hazardous material equal to or greater that the subject to the workers'compensation provisions of Section 3700 of the Labor amounts specified on the Hazardous Materials Information Guide? Code,I shall forthwith comply with those provisions. DYES ❑NO Applicant; Date; Will the intended use of the building by the applicant or future building occupant require a permit for the construction or modification from South WARNING: FAILURE TO SECURE WORKERS' Coast Air Quality Management District(SCAQMD)?See permitting checklist COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL for guidelines SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND DYES ❑NO CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000), IN ADDITION TO THE COST OF COMPENSATION, Will the proposed building or modified facility be within 1000 feet of the outer DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE boundary of a school? LABOR CODE, INTEREST,AND ATTORNEYS FEES DYES ❑NO CONSTRUCTION LENDING AGENCY I have read the Hazardous Material Information Guide and the SCAQMD I hereby affirm that under the penalty of perjury there is a construction lending permitting checklist.I understand my requirements under the State of agency for the performance of the work which this permit is issued (Section California Health&Safety Code,Section 25505 and 25534 concerning 3097 Civil Code) hazardous material reporting. OWNER BUILDER DECLARATIONS DYES ❑NO I hereby affirm under penalty of perjury that I am exempt from the Contractor's Date License Law for the reason(s)indicated below by the checkmark(s)I have placed PROPERTY OWNER OR AUTHORIZED AGENT next to the applicable item(s)(Section 7031.5.Business and Professions Code: Any city or county that requires a permit to construct, alter,improve,demolish, EPA RENOVATION,REPAIR AND PAINTING(Hj P) or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the The EPA Renovation,Repair and Painting(RRP)Rule requires contractors provisions of the Contractor's State License Law(Chapter 9 (commencing with receiving compensation for most work that disturbs paint in a pre-1978 Section 7000)of Division 3 of the Business and Professions Code)or that he or residence or childcare facility to be RRP-certified firms and comply with she is exempt from Iicensure and the basis for the alleged exemption. Any required practices.This includes rental property owners and property violation of Section 7031.5 by any Applicant for a permit subjects the applicant to managers who do the paint-disturbing work themselves or through their a civil penalty of not more than($500).) employees.For more information about EPA's Renovation Program visit: www.epa.gov/lead or contact the National Lead Information Center at ❑ I, as owner of the property, or my employees with wages as their sale 1-800-424-LEAD(5323). compensation,will do( )all of or( )porting of the work, and the structure is not intended or offered for sale.(Section 7044,Business and Professions Code; The Contractor's State License Law does not apply to an owner of a property ❑An EPA Lead-Safe Certified Renovator will be responsible for this project who, through employees' or personal effort, builds or improves the property, provided that the improvements are not intended or offered for sale.If,however, Certified Firm Name: the building or Improvement is sold within one year of completion, the Owner- Builder will have the burden of proving that it was not built or improved for the Firm Certification No.: purpose of sale). ❑ I, as owner of the property an exclusively contracting with licensed ❑No EPA Lead-Safe Certified Firm is required for this project because: contractors to construct the project(Section 7044,Business and Professions Code:The Contractor's License Law does not apply to an owner of a property who builds or improves thereon, and who contracts for the projects with a licensed contractor(s)pursuant to the Contractors State License Law). If your project does not comply with EPA RRP rule please fill out the RRP Acknowledcement. 1 APPLICATIONBUILDING & SAFETY PERMIT/PLAN CHECK Menifee DATE PERMIT/PLAN CHECK NUMBER VM1�'O J�O� TYPE: O COMMERCIAL JR RESIDENTIAL O MULTI-FAMILY O MOBILE HOME O POOL/SPA O SIGN SUBTYPE: fit ADDITION O ALTERATION O DEMOLITION O ELECTRICAL O MECHANICAL O NEW O PLUMBING O RE-ROOF-NUMBER OF SQUARES DESCRIPTION OF WORK G e r PROJECTADDRESS 337 i ( t I R-1 ASSESSOR'S PARCEL NUMBER 3$I/v c/d// , g LOT �_ TRACT OWNERNAME T;AON"ir ADDRESS Sqm� PHONE EMAIL APPLICANT NAME / e k VI(5 h2 ec ADDRESS $qmC PHONE EMAIL CONTRACTOR'S NAME - OWNER BUILDER? MYES O NO BUSINESS NAME ADDRESS PHONE EMAIL CONTRACTOR'S STATE LIC NUMBER LICENSE CLASSIFICATION VALUATION$ (' SO FT / !J j L SQ FT APPLICANT'S SIGNATURE_ /'---. —�_-_. DATE I/ D 1� DEPARTMENT DISTRIBUTION CITY OF MENIFEE BUSINESS LICENSE NUMBER BUILDING PLANNING ENGINEERING FIRE GREEN I SMIP INVOICE (/ ��I PAIDAMOUNT AMOUNT b.`� OCASH OCHECK# OCREDITCARD VISA/MC PLAN CHECK FEES PAIDAMOUNT OCASH OCHECK# 0 CREDIT CARD VISA/MC OWNER BUILDER VERIFIED O YES O NO DL NUMBER NOTARIZED LETTER O YES O NO City of Menifee Building&Safety Department 29714 Houn Rd. Menifee, CA 92586 951-672-6777 www.cityofinenifee.us Inspection Request Line 951-246-6213 Greenhouse Dimensions Construction shall comply with the 2013 California Building Codes u J 18' 36' City of Menifee Building Dept DEC 0 4 201b Received AdOBBY HO " SF a ° This structure is made using the same ROLL-FORMED components utilized in Conley's commercial gree _0ous&ifee uilding & Safety Dept. structures. r-� - NOV 0 & 2015 x3 n jf; This structure is engineertlYd r eAf az,s1a idard 12 LB live load 85 mph wind or 30 LB ground snow 85 mph wind per the International Building Code(IBC).Alternative loadings are available upon request. l f _ Main Features: • Superior ROLL-FORM legs,trusses and purlins ensure unmatched structural integrity • • • • • • ' _ _ Available in pre-packagedkits that include 6mm polycarbonate covering(warrantied for • • • • • ' • 10 years against discoloration)and a 3'x 6'-8" storm door • - • 13 gauge ROLL-FORMED legs are stronger than conventional greenhouse columns Simplified arch to leg connection enhances Conley's superior strength ROLL-FORMED design • Heavy duty legs bolt directly to base plate • Aluminum end bar"seals"the house against rain and snow L.\: • Aluminum ridge bar creates a"flashing"for roof coverings • ROLL-FORM components nest one into the ROLL-FORM Superior Custotnizatlon other during shipment,substantially reducing ROLL-FORMED freight costs Connections �=J Sizin€�, �1 Widths:9; 12'and 18' C y\ 'J ' Our Greenhouse Department is ready «, to answer all of your Conley's Structure - questions. Call Toll Free 800-377-8441 !.i www.conleys.com - ONLE Y 'S IIIV ;•: _�(��l�/(/ - IIII Ih.� 11...............IU� �IIII�III\IIIIIII� m�Illll�:.�. I f'///���'///,,'I ��j� ��/ • __/ - I uuu`nnun.nnw 1.. "'IIIIII„1//�l/� -'-• III I II 'vII�I1��lI I11��..-....., ,IIIIIIII �.IIIIIIIII II lllllll III. ����IIIIIII�I••. IIII III�� IIIIIIIIIi:::::. :III�Iaolllq \IIII...:,;; IIIIIII Illlllll�lul�� •, . "'"'01111IIVii;Illll Hillllllllllll'` :lIulll .....■■......... IIIIIIIIIIIIIIIIII �. . - uu000..ERNE 'Rum IIIIIIIIIIIIIII�IIIi I0iiiiiiiisoIn no i IIIIIII�IIIun ,.., IIIIIIIIIIIIII • � .;;III;;; • 1j1j1j11`'` IIIIIIIIII1111::;::_11j1j� • 1 nmumnunmmai nnnun...... '. i 1 / • � TABLE OF CONTENTS INTRODUCTION--------------------------------------------------------------------Page 1 DISCLAIMER ------ -- -_----------------------------------------Page I NOTICE TO CONLEY'S CUSTOMERS PROTECT YOURSELF FROM ADDED COSTS-----------------------Page 1 of 2 WARRANTY------------------------ ---Page 2 FOUNDATION LAYOUT--------------------------------------- Page 3 END WALL TRUSS ASSEMBLY-------- ---------------- ----Page 4 of INTERIOR TRUSS ASSEMBLY------,----------- - Page 6 TRUSS ASSEMBLY------------- -------------------------Page 7 of 9 INTERIOR TRUSS ASSEMBLY------------------- ----- Page 10 RIDGE BAR INSTALLATION----------------------------------------------------Page 10 BRACE CABLE INSTALLATION-----------------------------------------—---------Page I 1 of 12 END WALL COLUMN INSTALLATION------------------------------------------- Page 13 of 14 END GIRT INSTALLATION----------------------------------------------------Page 15 of 16 END WALL SWING DOOR INSTALLATION-------------------------------Page 17 of 18 END WALL GLAZING INSTALLATION--------------------------------------------Page 19 of 21 END WALL LEXAN PREPARATION------ -----__-___ Page 22 of 23 END WALL LEXAN INSTALLATION------------------------ ----Page 24 of 26 SIDE WALL AND ROOF LEXAN INSTALLATION------------- -Page 27 of 29 UNI-VENT INSTALLATION OPTION------------------------_ -- Page 30 STATIONARY BENCH OPTION TABLE TOP ASSEMBLY-----------------Page 31 of 33 SWAMP COOLER INSTALLATION OPTION---------------------------Page 34 INSTALLATION OF SHUTTERS ------ Page 35 INSTALLATION OF SHADE CLOTH----------------------------Page 36 UNI-VENT INSTALLATION------------------------------------Page 37 lk I INTRODUCTION SHOULD YOU HAVE ANY QUESTIONS CONCERNING THESE INSTRUCTION,COMPONENTS ETC...,PLEASE CONTACT US DIRECTLY.WE WELL BE GLAD TO ANSWER ANY QUESTIONS CONCERNING OUR MANUFACTURED PRODUCT. INCLUDED IN THIS PACKAGE ARE INSTRUCTIONS AND DETAILED DRAWINGS PERTAINING TO YOUR CONLEY'S GREENHOUSE SYSTEM.STUDY THE INSTRUCTIONS BEFORE BEGINNING CONSTRUCTION TO BECOME FAMILIAR WITH OUR PRODUCT AND HOW IT IS ASSEMBLED. STORE ALL MATERIALS OFF THE GROUND ON WOOD BLOCKS.PROTECT ALL YOUR MATERIALS FROM THEFT AND/OR DAMAGE.YOU MAY WISH TO DISCUSS BUILDERS RISK INSURANCE WITH YOUR INSURANCE AGENT. DISCLAIMER THE FOLLOWING INSTRUCTIONS ARE GIVEN AS SUGGESTED GUIDELINES FOR GENERAL INSTRUCTIONS. CONLEY'S MANUFACTURING AND SALES OR ANY OF THEIR EMPLOYEES SHALL NOT BE RESPONSIBLE FOR DAMAGES RESULTING FROM PURCHASERS IMPLEMENTATION OF THESE INSTRUCTIONS.PURCHASERS ALONE SHALL BE RESPONSIBLE FOR CONFORMANCE WITH ALL APPLICABLE LAWS,ORDINANCES,AND SAFETY STANDARDS IN CONSTRUCTING THIS GREENHOUSE AND ALL EQUIPMENT INSTALLED THEREIN. NOTICE TO CONLEY'S CUSTOMERS PROTECT YOURSELF FROM ADDED COSTS ALL PRODUCTS ARE SOLD F.O.B.SHIPPING POINT,AND THE ATTACHED MEMORANDUM COPY OF BILL OF LADING THAT INDICATES THAT MATERIAL SHIPPED HAS NOW,BY LAW,BECOME YOUR PROPERTY AND IS AN ACKNOWLEDGMENT BY THE TRANSPORTATION COMPANY OF THE RECEIPT OF THE MATERIALS IN GOOD CONDITION. SAFE DELIVERY OF THIS SHIPMENT IS NOW THE RESPONSIBILITY OF THE CARRIER WHO ACTS AS YOUR AGENT.WE WILL BE GLAD TO RENDER ASSISTANCE TO TRACE AND RECOVER LOST GOODS. EXAMINE THE SHIPMENT CAREFULLY BEFORE SIGNING THE FREIGHT BILL.IF ANY DAMAGE IS NOTED, OR OF THE NUMBER OF PIECES DOES NOT AGREE WITH THE BILL OF LADING,INSIST THAT SHORTAGE OR DAMAGE BE NOTED ON THE FREIGHT BILL BY THE CARRIERS AGENT.FAILURE TO DO SO MAY JEOPARDIZE YOUR RECOVERY. DO NOT REFUSE SHIPMENT AS THIS IS YOUR PROPERTY AND REFUSAL CAUSES UNNECESSARY DELAYS AND SHORTAGE EXPENSES.ARRANGE WITH CARRIER WITHIN 15 DAYS TO INSPECT AND MAKE REFERENCE THERE TO ON THE FREIGHT BILL.CONSULT YOUR CARRIER FOR DISPOSITION OF DAMAGED ARTICLES. 1 MAKE YOUR CLAIM PROMPTLY,THE TRANSPORTATION COMPANY WILL NOT CONSIDER A CLAIM UNLESS IT IS PRESENTED WITHIN(9)MONTHS FROM THE DATE OF SHIPMENT.CARRIERS AGENT WILL ASSIST YOU IN PREPARING A CLAIM. CLAIMS FOR LOSS OR DAMAGE AND TRANSPORTATION CHARGES RESULTING FROM SHIPPING,MUST NOT BE DEDUCTED FROM THE INVOICE,NOR PATENT INVOICES WITH HELD AWAITING ADJUSTMENT OF SUCH CLAIMS,SINCE IT IS THE FUNCTION OF THE CARRIER TO GUARANTEE SAFE DELIVERY. CHECK THE ITEMS RECEIVED WITH THE INVOICE.OF THERE IS ANY DISCREPANCY CONTACT US IMMEDIATELY GIVING FULL PARTICULARS.CLAIMS FOR SHORTAGE ATTRIBUTED TO OUR COUNT IN PACKAGE MUST BE MADE WITHIN 10 DATES FORM THE SHIPMENT IS RECEIVED. NO MERCHANDISE MAY BE RETURNED FOR CREDIT WITHOUT A RETURN GOODS TAG AND SHIPPING INSTRUCTIONS FROM THE FACTORY. WARRANTY CONLEY'S MANUFACTURING AND SALES,THEIR EMPLOYEES OR REPRESENTATIVES,WILL NOT BE RESPONSIBLE FOR ANY DAMAGES TO GREENHOUSE COVERINGS,STRUCTURES,CROPS OR EQUIPMENT WHEN USED IN CONDUCTION WITH OUR TUBE-LOCK,OR ANY OTHER LOCKING DEVICE MANUFACTURED BY CONLEY'S MANUFACTURING AND SALES OR OTHERS. CONLEY'S MANUFACTURING AND SALES ONLY PROVIDES THE MEASUREMENTS AND ANCHOR BOLT FOR SECURING THE HOBBY HOUSE TO THE GROUND.CUSTOMERS ARE RESPONSIBLE FOR ALL INFORMATION PERTAINING TO AND INSTALLING FOOTINGS OR CONCRETE SLABS. REFER TO THE ENGINEERED PRINTS OR THE LOCAL BUILDING DEPARTMENT FOR FOOTING SIZES. REFER TO PAGE 3 FOR ANCHOR BOLT LOCATIONS. 2 SETTING THE FOUNDATION 216"OUTTOOUT 3 1/Ib' 3 l/16" 116 f 6C 7 �--�5--- /�;fir ENDWALL FOOTING l�J C C ' I' 2I6-0=00UT , 7" 3 1/16' 1— —I 3 1/19 2' 312" �64]/16"11�1 75' I 1 n"687116"112" 31/2" 6 r BACK OF THE HOBBY HOUSE I I I I I I I I I I I I I I I I I I I I I - I I " I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I 1 I I I I I d I 0 r I o I j 0 s _ I I.LAYOUT FOUNDATION. ,. I a 2.USE TEMPLATES TO SET ANCHOR BOLTS. O I 3.EMBED ANCHOR BOLTS THEM 7". C I 4.POUR FOUNDATION. I _ 5.DIMENSIONS PROVIDED AREFROM I I EDGE OF SLAB NOT FORM I I I I I I I I I I I I I I I I I � I I I I I I I I I I I I I I I I I I I I I I I I I I I - I I - I I I I I I I I I I I I I I I I V L_____FRONT OF THE HOBBY HOUSE_____ ^ a �112"R47/1 fi"I IR" 75 112"647116"112" 3111V 31/Ifi' 216"OUT TO OUT 31/16 216OUTT000—T ' 3111 112 I l2' 11/2" -y 64]/16 75" 7/I6" 6" ENDWALL FOOTING lnJ 3 oS iv .0£ .Z/l OZ M M e Z Z Z J � J a a a a y\O j My � a a TW V1 e O � M h � a rl 11�1 1� W 4 1.INSTALL THE PURLIN TABS TO THE LEGS WITH A 3/8"X 2 1/2"MACHINE BOLT USING A 1 3/4"LONG SPACER TABS AT THE TOP OF 2 PURLIN TABS.AT THE TOP PURLIN TAB,ATTACH A BRACE LUG USING THE SAME BOLTS AS THE OTHER TABS. I- #T0031211 TAB CROSSBAR PURUN TO 9 1/2" fT0031210 TAB 9 1/2" SPACE 3/8" X 2 1 MACHINE BOLT #B9970500 COLUMN 9 1/2" LEG #C0000590 a 0 4 \ o 2.ON THE END WALL TRUSSES ONLY ATTACH THE TOP CHORD OF TRUSS TO THE LEG WITH A 3/8"X 2 1/2" MACHINE BOLT AND A 1 1/2"LONG SPACER TAB AT THE UPPER HOLE OF THE SPLICE. BRACE LEG UPPER CHORD o #B0005035 #coosaezo � jj TAB CROSSBAR PURLIN TO 9 1/2" #T0031210 a / 3/8" X 2 1/2" MACHINE BOLT #B9970500 TAB SPACER #T0031212 ROLL FORMED LEG #c000O590 5 INTERIOR TRUSS ASSEMBLY 1.ATTACH 3 PURLTN TABS TO EACH LEG WITH A 3/8"X 2 1/2"MACHINE BOLT AND USING A 1 3/4"LONG SPACER TAB AT THE TOP 2 PURLIN TABS.AT THE LOWER HOLE OF THE SPLICE,INSTALL A PURLIN TAB AND SECURE IT WITH A 3/8"X 3"EYE BOLT. e 0 BRACE LUG #B0005035 TAB CROSSBAR PURLIN TO 9 1/2" " #T0031210 O TAB 9 1/2" SPACER #T0031211 3/8" X 2 1/2" ROLL FORMED LEG MACHINE BOLT #C0000590 #89970500 ` EYEBOLT WELDED 3/8" X 3" #T0000330 2.ATTACH THE TOP CHORD TO THE LEG BY BOLTING THE TOP HOLE OF THE LEG TO THE SECOND HOLE OF THE TOP CHORD WITH(1)3/8"X 2 1/2"MACHINE BOLT AND A 1 1/2"LONG SPACER TAB. 3.SLIDE THE PURLIN TAB OVER THE TOP CHORD AND ALINE IT WITH WITH SECOND HOLE OF THE LEG AND BOLT IT ON WITH(1)3/8"X 2 1/2"MACHINE BOLT AND A 1 1/2"LONG SPACER. BRACE LEG UPPER CHORD #B0005035 #C0054820 TAB CROSSBAR PURLIN TO 9 1/2" #T0031210 i 0 3/8" X 2 1/2" MACHINE BOLT #139970500 TAB SPACER #T0031212 ROLL FORMED LEG #C0000590 6 TRUSS ASSEMBLY Y ' i a (12) 3 MACHINE BOLT #B9970500 e 1.CONNECT 2 COLUMN/TOP CHORD ASSEMBLIES WITH A CHEVRON SPLICE AND(4)3/8"X 2 1/2" MACHINE BOLTS. *1/2- LRON SPLICE ASMB. 0962 TOP CHORD JC0054820TOP CHORD #CO054820 J 7 2.ATTACH THE COLUMN BASE PLATES TO 1/2"ANCHOR BOLTS IN THE FOUNDATION WITH(2) 1/2"HEX BOLTS.SEE DETAIL BELOW. SEE BELOW FOR CONNECTION \J 3.STAND THE TRUSS ASSEMBLY ONTO THE BASE PLATE STUB AND SECURE IT WITH (2)3/8"X 2 1/2" MACHINE BOLTS. COLUMN (2) 3/8" X 2 1/2" jC0000590 MACHINE BOLT �B9970500 (2) 1/2" HEX NUTS #N9970320 0 a 0 COLUMN BASE PLATE #C0000950 0 0 8 4.STAND AND SECURE THE NEXT TWO TRUSSES(3 TOTAL),THEN INSTALL THE PURLINS. Y2 JJ �O 0 9 r2 �J 2� 0 9 9 INTERIOR TRUSS ASSEMBLY 1.ATTACH THE PURLIN/GIRTS TO THE PREVIOUSLY INSTALLED TABS WITH(2)5/16"X 1 3/4"MACHINE BOLTS PER SIDE,PER GIRT. 5/16" X 1 3/4" MACHINE BOLT #B9970270 � F TAB CROSSBAR PURLIN t PURLIN #TO031210 #P0001600 UPPER CHORD TAB CROWN SPACER #CO054820 #TO031211 RIDGE BAR INSTALLATION 1.AFTER INSTALLING ALL OF THE PURLINS,INSTALL THE RIDGE BAR WITH(2)3/8"X V CARRIAGE BOLTS PER TRUSS.(SLIDE THE BOLTS THROUGH THE GROOVE IN THE RIDGE BAR). ALUM. RIDGE BAR #A0010126 #AO010127 (2) 3/8" X 1" CARRIAGE BOLT #B9971590 TOP CHORD #CO054820 (4) 3/8" X 2 1/2" MACHINE BOLT #B9970500 0 O r I I L-0 O 0- SPLICE CHEVRON ASMS #S0000962 10 BRACE CABLE INSTALLATION 12 3 / � 2 12 1. SLIDE THE 3/8"X 31'-4"CABLE THROUGH THE PREVIOUSLY INSTALLED EYE BOLT AT THE CHEVRON SPLICE.DIVIDE THE CABLE IN HALF AND CLAMP 1T WITH CABLE CLAMP. SPLICE CHEVRON fS0000962 TOP CHORD #C0054820 (4) 3/8" X 2 1/2" MACHINE BOLT i #89970500 0 O r � LO OJ 3/16" X 31-4' 3/8" X 3" BRACE CABLE EYE BOLT #B0000250 #T0000330 DETAIL I 11 2.ATTACH THE ENDS OF THE PREVIOUSLY ATTACHED CABLE FROM THE CHEVRON SPLICE TO THE BRACE LUG ATTACHED TO THE FIRST ROOF PURLIN ABOVE THE BEND.ATTACH THE X'BRACE CABLES TO THE BRACE LUGS AT THE TOP SIDE GIRT.USE 2 CABLE CLAMPS PER CONNECTION TYPICAL. BRACE CABLE 3/16" #B0000105 3/8- X 3" EYE BOLT #T0000330 COLUMN BRACE LUG #C0000590 #BO005035 TAB CROSSBAR PURLIN #T0031210 3/8" X 2 1/2" MACHINE BOLT #B9970500 DETAIL 2 3.ATTACH THE ENDS OF"X"BRACE CABLES TO THE EYE BOLTS AT THE BOTTOM GIRT TAB WITH 2 CABLE CLAMPS PER CONNECTION. UPPER CHORD #C0054B20 TAB PURLIN 3/B" X 3" #T0031210 EYE BOLT #T0000330 i BRACE CABLE 3/16" rT 711� /1B0000108 PURLIN L #P0001600 TAB CROWN SPACER #T0031211 (2) CABLE CLAMPS #C9970230 DETAIL 3 12 END WALL COLUMN INSTALLATION 13 1 114 I.SLIDE TOP OF VEND WALL COLUMN ASSEMBLY INTO THE TOP CHORD AND SET BASE PLATE ONTO PREVIOUSLY INSTALLED ANCHOR BOLTS.(SEE DETAIL BELOW). 2.PLUMB COLUMN AND SECURE TO UPPER CHORD WITH(2) 14-14 X V TEK SCREW EACH SIDE OF UPPER CHORD.(SEE DETAIL 2 PAGE 14) k�FC6�754�W HORD 0 CUT COLUMN IF NECESSARY (2) 14-14 X 1" TEK SCREWS #S9970052 1 1/2" SO. END WALL COLUMN ASSEMBLY /C0003320 13 3.AFTER SECURING THE TOP OF THE COLUMN AT THE UPPER CHORD,PLUMB THE COLUMN AND SECURE IT TO THE FOUNDATION WITH(2) 1/2"HEX NUTS PER COLUMN AT ANCHOR BOLTS. COLUMN END WALL ASMB #C0003320 J - BOLTS 3/8" X 8" (2) 3/8" HEX NUT 14 END GIRT INSTALLATION 2 16 1 15 2 1 16 15 I.LOCATE POSITION OF END WALL GIRTS(APPROX.30"APART)AND INSTALL THE TAB WITH(2) 14-14 X 1"TEK SCREWS. 2.USING CLAMPS(VICE GRIPS)SECURE END WALL GIRT TO TAB AND ADJUST LEVEL.WHEN LEVEL SECURE TO TAB WITH(2) 14-14 X I"TEK SCREWS AND(4) 10-16 X 3/4"TEK SCREWS. TAB END GIRT #T0030890 COLUMN 9 1/2" #C0000590 TEK SCREWS #S9970052 (4) 10-16 X 3/4" TEK SCREWS #S9970DIO �ci I GIRT END #Go041020 DETAIL 1 15 3.AFTER END WALL GIRTS ARE SECURED TO THE COLUMN AND TRUSS,SECURE THE GIRTS TO THE END WALL UPRIGHTS WITH(2) 10-16 X 3/4"TEK SCREWS. COLUMN END WALL ASMB. #C0003320 (2) 10-16 X 3/4" TEK SCREW #S9970010 END GIRT #00041000 OR #G0041020 16 END WALL SWING DOOR INSTALLATION 1.ATTACH THE DOOR JAMBS TO THE INSIDE FACE OF THE END WALL UPRIGHTS WITH A 10-16 X 3/4"TEK SCREWS AT EACH GIRT AND A 10-16 X 3/4"TEK SCREWS TO THE FACE OF THE GIRT. 10-16 X 3/4" TEK SCREW #S9970010 END WALL GIRT #G0041000 10-16 X 3/4" TEK SCREW IC #S9970010 DOOR JAMB jJ0000101 2. SLIDE DOOR AND FRAME INTO THE OPENING BETWEEN THE PREVIOUSLY INSTALLED DOOR JAMBS.MAKE SURE DOOR AND FRAME ARE PLUMB AND SCREW THE FRAME TO THE FACE OF THE DOOR JAMBS WITH(22) 10-16 X 3/4"TEK SCREWS. (22) 10-16 X 3/4" END WALL DOOR FRAME TEK SCREW #S9970010 DOOR STORM #D9970310 17 3.AFTER THE DOOR HAS BEEN SECURED INTO END WALL DOOR FRAME ATTACH THE DOOR FLASHING TO THE OUTSIDE OF T14E DOOR TRIM WITH 10-16 X 3/4"TEK SCREWS 12"ON CENTER. (22) 10-16 X 3/4" TEK SCREW 12" ON CENTER 59970010� END WALL DOOR FRAME AND SWING DOOR DOOR FLASHING $F0000200 JAMB DOOR COLUMN END WALL ASMB #J0000101 #C0003320 END WALL GIRT #G0041020 DOOR STORM #D9970310 FLASHING DOOR #F0000200 10-16 X 3/4" TEK SCREW 12" ON CENTER #S9970010 TOP VIEW 18 END WALL GLAZING INSTALLATION 1. INSTALL THE PCSS BASE&WASHER FOR PCSS(#W9970300). 6'-0" 6'-0" 3'-0" 1 20 ti 15" 14" 14" 14" 15" B L a 4 Y 3 21 e v • a a v v : a 4 21 19 1. INSTALL THE END BAR TABS AT ALL OF THE PURLIN TABS ON THE END WALL WITH A 5/16"X l 3/4" MACHINE BOLT. END BAR TAB #T0049887 ® 5/16" X 1 3/4" MACHINE BOLT PURLIN TAB #B9970270 #TO031210 DETAIL 1 2.INSTALL THE END BAR ON THE COLUMNS WITH A 10-16 X 3/4"TEK SCREWS 9"ON CENTER AND ON THE UPPER CHORD WITH A 10-16 X 3/4"TEK SCREWS 9"ON CENTER.MAKE SURE THAT THE END BAR AND FACE OF END GIRTS ARE FLUSH. 10-16 X 1 1/4" TEK SCREW ALUM PCSS CAP END BAR #S9970011 #A0080123 #AO080240 OR #A0080250 PCSS 6MM (197") #AO080122 0 PURLIN TAB #TO031210 PURLIN #P0001600 COLUMN / UPPER CHORD DETAIL 2 20 3. INSTALL PCSS BASE AT CENTER LINE OF END WALL,PLUMB AND SECURE TO END WALL GIRTS WITH A 10-16 X 3/4"TEK SCREWS. 4.PCSS PIECE#A0080124(2)PER END WALL AND#A0080127 10'-0" PIECE NEEDS TO BE CUT IN HALF I PER END WALL. END WALL GIRT #G0041020 LEXAN GLAZING BAR BASE #A0080129 DETAIL 3 5.ATTACH THE PANEL END CAP TO THE BOTTOM END WALL GIRT WITH 10-16 X 3/4"TEK SCREW 9"ON CENTER.MAKE SURE THAT THE PANEL END CAP IS AS CLOSE TO THE GROUND AS POSSIBLE. COLUMN END WALL ASMB #C0003320 PCSS 6MM LEXAN #A0080124 (144") #A0080127 (120") ALUM PCSS PANEL END CAP #A0070361 GIRT END WALL #G0041020 DETAIL 4 21 END WALL LEXAN PREPARATION 1.MAKE SURE ALL GLAZING IS INSTALLED PROPERLY. 2.CUT ONE SHEET OF LEXAN#A0080127 EXACTLY IN HALF(35 5/8"TO 35 3/4") 3.PLACE A LEXAN SHEET ON THE GLAZING BAR BASE AND IN THE PANEL END CAP. 4.MARK TOP OF SHEET WHERE LEXAN WILL SLIDE INTO ALUM.GABLE END BAR. M M N N M N LJ M N M ^ N b 22 5.TRIM LEXAN AT PREVIOUSLY MADE MARK. 5 5 5 5 6.REMOVE APPROX.2"OF MASKING FROM ALL SHEET EDGES AND FASTENING POINTS.TAPE TOP OF SHEET WITH SILVER TAPE. 6 6 6 6 23 END WALL LEXAN INSTALLATION s ro 2 4 25 26 3 5 25 26 3 25 1 � 25 25 2�F 1.INSTALL SHEET INTO PANEL END CAP.(SIDEWALL) LEXAN SIDEWALL COLUMN ASSEMBLY SIDE WALL GIRT PANEL END CAP #A0070364 O DETAIL l 2.INSTALL SHEET ON GLAZING BAR BASE.(ENDWALL) END WALL GIRT #G0041020 LEXAN 6-0" IS" 14" 14"--1-14" 15" T'GLAZING IWASHER FOR PCSS BAR BASE /fW9970300 #AOO80129 DETAIL 2 3.INSTALL SHEET INTO GABLE END BAR.PUSH THE CLOSURE STRIP BETWEEN THE LEXAN SHEET AND THE GABLE END BAR. ALUM. GABLE END BAR #A0080240 R.H. #AOOBO250 L.H. CLOSURE STRIP #C9970365 LEXAN COLUMN / UPPER CHORD DETAIL 3 25 4.SECURE GLAZING BAR CAP TO BASE WITH 10-16 X 3/4"TEK SCREWS 9"ON CENTER. GIRT LEXAN E;L#G�00417020 10-16 X 1/2" GLAZING BAR CAP TEK SCREW #A0080128 #S9970043 GLAZING BAR BASE #A0080129 DETAIL 4 5.SECURE LEXAN TO END WALL GIRTS WITH(4) 10-16 X 1 1/4"TEK SCREW WITH 7/8" WASHER AND(4)3/8" THICK WASHERS PER SHEET. END GIRT #G0041020 LEXAN 10-16 X 1 1/4" TEK SCREW WITH 7/8" WASHER #S9970017 BLACK SQUARE RUBBER WASHER #W9970300 DETAIL 5 26 SIDE WALL AND ROOF LEXAN INSTALLATION 1. REMOVE MASKING 2"AROUND EDGES AND FASTEN POINTS, 2. SLIDE LEXAN SHEET INTO RIDGE BAR WITH GRAY CLOSURE STRIP ON TOP. RIDGE BAR CLOSURE STRIP CHEVRON SPLICE #C9970355 #S0000962 LEXAN TOP CHORD #C0054820 r' 0 LDo o Oo� 27 3.CENTER LEXAN SHEETS OVER UPPER CHORDS. LEXAN SHEET LEXAN SHEET I UPPER CHORD / COLUMN I 4.SECURE THE LEXAN TO THE PURLINS WITH 10-16 X 1 1/4"TEK SCREWS WITH WASHER. LEXAN 10-16 X 1 1/4" TEK SCREW WITH 7/8" WASHER #59970017 END GIRT #G0041020 10-16 X 1 1/4" TEK SCREW WITH 7/8" WASHER #59970017 15" 14" 14" 14" IS" 28 5.INSTALL A GLAZING BAR CAP AT THE END WALLS AND UPPER CHORD COLUMN SHEET SPLICES. (6'APART TYPICALLY) 10-16 X 1 1/4" TEK SCREW AT UPPER CHORD #S9970D11 ALUM. GABLE END BAR #AO080240 R.H. PCSS CAP #AO080250 L.H. $AO080123 PCSS PANEL (197") �1A0080122 CLOSURE STRIP O C9970365 PCSS PANEL PURLIN #P0001600 COLUMN / UPPER CHORD END WALL SECTION 10-16 X 1 1/4" TEK SCREW AT UPPER CHORD #S9970011 LEXAN PCSS CAP #AO080123 5 0 F;P0001600URLIN COLUMN / UPPER CHORD INTERIOR TRUSS/COLUMN SECTION 29 UNI - VENT INSTALLATION OPTION 1.PLACE UNI-VENT ASSEMBLY AT THE CENTER OF THE BUILDING.MAKE SURE THAT THE TOP FLASHING IS INSIDE OF THE RIDGE BAR, 2.SECURE THE ASSEMBLY WITH 10-16 X 3/4"TEK SCREWS AT 12"ON CENTER AT THE RIDGE BAR AND PURLIN(IF APPLICABLE). 3.SECURE THE ASSEMBLY TO THE UPPER CHORD(S)WITH 10-16 X 3/4"TEK SCREWS. 4.FOLLOW THE LEXAN INSTALLATION INSTRUCTIONS SUBSTITUTING THE ASSEMBLY FLASHING FOR THE RIDGE BAR. 0 ( O O MZO O W n X V T 0 2 N O'Ik I O N U b J N ao 0 OW Z O y N J N C Vh Y W F = U J N N Q F Z > o > z I 2 _ V z a O r ° 30 M K O U X NO^i D w i F% O 3n STATIONARY BENCH OPTION TABLE TOP ASSEMBLY 1.ASSEMBLE THE STATIONARY BENCH TABLE TOP FRAME BY PLACING THE TABLE TOP ENDS AND SIDES INTO A RECTANGULAR SHAPE,OVERLAPPING THE PIECES AT THE CORNERS.SECURE THEM TOGETHER WITH A 10-16 X 1/2"TEK SCREW PER CORNER. 2.SLIDE 5 CROSSBARS INTO THE TABLE TOP SIDES AND ALIGN THEM WITH THE HOLES PROVIDED, APPROXIMATELY EVERY 24".SECURE THE CROSSBAR WITH(2) 10-16 X 1/2"TEK SCREW,ONE AT EACH END,FROM THE TOP AND(4) 10-16 X 1/2"TEK SCREW,TWO AT EACH END,FROM THE BOTTOM. 3.PLACE THE TABLE TOP FRAME ON TOP OF THE 2 LEG RAILS AND ALIGN THE LEG RAILS WITH THE HOLES IN THE CROSSBARS.SECURE THE LEG RAILS WITH(1) 10-16 X 1/2"TEK SCREW AT EACH TABLE TOP END AND(2) 10-16 X 1/2"TEK SCREW AT EACH INTERSECTION OF THE LEG RAIL AND CROSSBARS. BENCH TABLE TO END B4004015 BENCH TABLE TOP SIDE #B4002065 ' 1 BENCH CROSSBAR 1 $84003070 1 FIGURE I FIGURE 2 i BENCH STATIONARY LEG RAIL #84001060 i r r rr li 11 rr r* 1' 11 rl rr 1' 1' ri it 11 11 r r r 11 11 i FIGURE 311 FIGURE 4 31 4.MEASURE UP FROM THE GROUND 29 1/21*AND MARK THE COLUMN/LEG FOR TAB LOCATION.ATTACH THE TAB,WITH(2) 14-14 X I"TEK SCREWS.PLACE 1 TAB PER COLUMN/LEG. 5.LIFT THE PRE ASSEMBLED TABLE TOP ONTO THE TABS AND SECURE IT WITH(2) 10-16 X 3/4"TEK SCREW PER TAB. 6. INSTALL THE LEG BRACE BY SECURING THE BRACE TO THE TABLE TOP WITH A 10-16 X 3/4"TEK SCREW PER BRACE.LEVEL THE TABLE,THEN SLIDE LEG BRACE INTO BENCH BRACE.PLACE(1) 10-16 X 3/4"TEK SCREW WHERE BRACES JOIN AND SECURE THE BOTTOM OF THE LEG BRACE TO THE COLUMN/LEG WITH A 3/8"NUT. 7.AFTER THE BENCH TABLE TOP FRAME IS PLUMB AND SECURE,INSTALL THE EXPANDED METAL TABLE TOP.SLIDE THE EXPANDED METAL ONTO THE FRAME AND SECURE IT WITH 10-16 X 3/4"TEK SCREW AND 1/4"FENDER PLATED WASHERS. TAB END WALL UPRIGHT TO ARCH T0030880� COLUMN #C0000590 FIGURE 6 FIGURE 5 EXPANDED METAL #S0070130 EXPANDED METAL #SO070110 FIGURE 8 FIGURE 7 1 ` 1 33 32 COLUMN 9 1/2" #C000590 TAB 10-16 X 3/4"� #T0030883 TEK SCREW / LEG RAIL —/// #B4001060 BENCH TOP SUPPORT #B4000121 10-16 X 3/4" TEK SCREW SIDE VIEW BENCH TOP SUPPORT #B4000122 i 3/8" X 2 1/4" MACHINE BOLT #89970490 _ c of o i i m i i DETAIL I 33 SWAMP COOLER INSTALLATION OPTION p G\Rt GOO�,R NO I S\O� E S�P�? aOJ56 S A GR �tP t NO.�CI.�pJ� COOLER TO GREEN HOUSE TRANSITION SWAMP COOLER STAND FRAME AND LEG ASSEMBLIES 14-14 X 1" O I \ �TEK SCREW 6N ! 30" S�P�Q PSS��9 3 \ MODEL NUMBER A \ / ES330 14" yy ES430 18" ES630 20" 1.LOCATE THE AREA WHERE COOLER WILL BE INSTALLED.ATTACH THE 2 VERTICAL COOLER MOUNTING GIRTS ON THE INSIDE OF THE END/SIDE GIRTS WITH 10-16 X 3/4"TEK SCREWS AT EACH END TO GIRT.SEE CHART ABOVE FOR VERTICAL GIRT SPACING. 2.ATTACH THE HORIZONTAL COOLER MOUNT GIRT TO THE FACE OF THE VERTICAL COOLER MOUNTING GIRTS WITH 10-16 X 3/4"TEK SCREW AT EACH END.SEE CHART ABOVE FOR HORIZONTAL GIRT SPACING. 3.SLIDE THE SWAMP COOLER STAND LEG INTO THE STAND ASSEMBLY AND POSITION AT OPENING. PLACE THE SWAMP COOLER ON STAND AND ALIGN THE OPENINGS. 4.SLIDE THE COOLER TO GREEN HOUSE TRANSITION THROUGH THE OPENING CREATED BY THE MOUNTING GIRTS.SECURE THE V FLANGE TO THE TOP AND BOTTOM HORIZONTAL GIRTS WITH 14-14 X I"TEK SCREWS AND SECURE THE 3" FLANGE TO THE SWAMP COOLER WITH 14-14 X 1"TEK SCREWS. A. INSTALLATION OF SHUTTERS I.PLACE SHUTTER ON THE OPPOSITE END FROM THE COOLER TO INSURE PROPER CIRCULATION OF AIR FLOW. 2. INSTALL VERTICAL GIRT CUT TO FIT BETWEEN HORIZONTAL GIRTS AND SCREW TOGETHER. 3. USE 10-16 X 3/4"TEK SCREWS TO SECURE TO HOUSE. END WALL GIRT END WALL GIRT VERTICAL GIRT SHUTTERS 10-16 X 3/4" TEK SCREW i ikSHUTrERS AL GIRT 10-16 X 3/4" TEK SCREWS SIDE VIEW OF VENT ISOMETRIC VIEW OF VENT COOLER END WALL GIRT SHUTTERS 10" ALUM. s� �i lull SHUTTERS1, CUT OUT FOR CLARITY VENT AT END WALL ISOMETRIC VIEW OF HOBBY HOUSE 35 INSTALLATION OF SHADE CLOTH 1.TO INSTALL SHADE CLOTH FIRST ATTACH ROPE HOOKS EVERY 18"ON CENTER TYPE AT THE GIRT SIDE WALL(UNLESS OTHERWISE STATED). 2.AT THE END BAR ATTACH ROPE HOOKS EVERY 18"ON CENTER TYPE.(UNLESS OTHERWISE STATED). 3.COVER HOBBY HOUSE WITH SHADE CLOTH,LASH SHADE CLOTH WITH ROPE AND HOOKS PREVIOUSLY INSTALLED. ROPE HOOK ROOF END BAR TEK SCREW DETAIL #2 SHADE CLOTH END WALL DETAIL #2 ROPE HOOK DETAIL ##- TEK SCREW DETAIF#1 36 SIDEWALL UNI - VENT INSTALLATION 1.PLACE UNI-VENT ASSEMBLY AT THE CENTER OF THE BUILDING. MAKE SURE THAT THE FLASHING IS INSIDE OF THE RIDGE BAR. 2. SECURE THE ASSEMBLY WITH 10-16 X 3/4"TEK SCREWS AT 12"ON CENTER AT THE RIDGE BAR AND PURLIN,IF APPLICABLE. 3. SECURE THE ASSEMBLY TO THE UPPER CHORD WITH 10-16 X 3/4"TEK SCREWS. FOR TAB PLACEMENT I.MAKE SURE WHEN INSTALLING TAB#U0000810,THE 3"SIDE IS DIRECTLY SCREWED ON TO THE FRAME AND NOT ONTO THE BAY LESS AUTO VENT. 2.SHOULD IT BE INSTALLED INCORRECTLY THIS WILL CAUSE THE BAY LESS AUTO VENT TO JAM AND ONLY OPEN ONE INCH OR SO WHERE AS THE VENT SHOULD FULLY OPEN TO 12",SEE FIGURE 3. r� FIGURE I S. / UNI - VENT TAB BAY LESS MOUNT #u0000Blo FIGURE 2 12" FIGURE 3 37 f - r i z � 5 t r F'� V .:T. ati .aAv.4t•k. i — v