PMT15-03415 City of Menifee Permit No.: PMT15-03415
29714 HAUN RD. Type: Residential Electrical
�ACCELA—> MENIFEE,CA 92586
MENIFEE Date Issued:
11/O6/2015
PERMIT
Site Address: 29091 GUAVA ST,MENIFEE, CA 92584 Parcel Number: 333-632-005
Construction Cost: $8,017.20
Existing Use: Proposed Use:
Description of SOLAR TR31582-1 MENIFEE HILLS
Work: 3.18 KW 12 MODULES
LOT 44
Owner Contractor
LENNAR HOMES OF CA, INC LENNAR HOMES OF CALIFORNIA INC
980 MONTECITO DR#302 25 ENTERPRISE
CORONA, CA 92879 ALISO VIEJO, CA 92656
Applicant Phone:9493498269
JEREMIAH ACAYTURRI License Number:728102
LENNAR HOMES OF CALIFORNIA INC
25 ENTERPRISE
ALISO VIEJO,CA 92656
Fee Descriptlon QQtt Amount!$)
Solar, Residential or Small Commercial 1 252.00
Building Permit Issuance 1 27.00
GREEN FEE 1 1.00
SMIP RESIDENTIAL 1 2.00
General Plan Maintenance Fee-Electrical 1 12.60
$294.60
The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and
specifications or from preventing builiding operations being carded on thereunder when in violation of the Building Code or of any other
ordinance of City of Menifee.Except as otherwise stated,a permit for construction under which no work is commenced within six
months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be
forfeited.
AA_Bldg_Permil_Template.rpt Page 1 of 1
PERMIT/PLANBUILDING & SAFETY APPLICATION
Menifee
milt
DATE 10/28/2015 PERMIT/PLAN CHECK NUMBER 1' 1" T5- l`5
TYPE: ❑COMMERCIAL ❑✓ RESIDENTIAL ❑MULTI-FAMILY ❑MOBILE HOME ❑POOL/SPA SIGN
SUBTYPE: ❑✓ ADDITION ❑ALTERATION []DEMOLITION ❑ELECTRICAL [-]MECHANICAL
❑NEW []PLUMBING ❑RE-ROOF-NUMBER OF SQUARES
DESCRIPTION OF WORK SOLAR PERMIT-Plan 2033 3.18 kW/12 PCS
Master Solar Plan#PMT14-00706
PROJECT ADDRESS 29091 Guava St, Menifee, CA 92584
ASSESSOR'S PARCEL NUMBER 333-632-005 LOT 44 TRACT 31582-1
PROPERTY OWNER'S NAME Lennar Homes of California, Inc.
ADDRESS 980 Montecito Dr., Suite 302
PHONE (951)817-3680 EMAIL leremiah.ecayturri@lennar.com
APPLICANT NAME Lennar Homes of California, Inc.
ADDRESS 980 Montecito Dr.,Suite 302, Carona,CA 92879
PHONE (951)817-3680 EMAIL leremiah.acaytum@lennar.com
CONTRACTOR'S NAME Lennar Homes of California, Inc. OWNER BUILDER? ❑✓ YES❑NO
BUSINESS NAME Lennar Homes of California, Inc.
ADDRESS 980 Montecito Dr.,Suite 302,Corona,CA 92879
PHONE (951)817-3680 EMAIL leremiah.acaytumi@lennarcom
CONTRACTOR'S STATE LIC NUMBER 728102 LICENSE CLASSIFICATION A&B
VALUATION$ $8,017.20 SO.FT L SO FT
APPLICANT'S SIGNATURE DATE
UYSTAFF USE ONLY
DEPARTMENT DISTRIBUTION aQ y` iJ CITY OF MENIFEE BUSINESS LICENSE NUMBER
BUILDING PLANNING ENGINEERING FIRE GREEN , sMIP
INVOICE G �Q PAIDAMOUNT
AMOUNT _ ` O CA O SH OCHELK# CREDIT CARD VISA/MC
PLAN CHECK FEES PAID AMOUNT O CASH O CHECK# O CREDITCARD VISA/MC
OWNER BUILDER VERIFIED OYES O NO DL NUMBER NOTARIZED LETTER O YES O NO
City of Menifee Building&Safety Department 29714 Houn Rd. Menifee, CA 92586 951-672-6777
www.citycfinenifee.us Inspection Request Line 951-246-6213
SYSTEM INFORMATION BUYER ACKNOWLEDGES THAT THE SOLAR MODULES TO BE INSTALLED
ITEM OTY MFR. MODEL ON THE ROOF OF THE HOME WILL BE SUBSTANTIALLY IN THE
SYSTEM SIZE 3.16 KW LOCATIONS INDICATED BY THE ILLUSTRATION.
MODULE 1 12 PCS. HYUNDAI I HIS-SZ65RG(265W) BUYER: /
INVERTER 1 12 PCS.1 ENPHASE I M215-60-2LL-S22-IG 1 r F M
ROOF TYPE I TILE W/COMPOSITE SHINGLE UNDER ARRAY DATE: /+
SUB-ARRAY INFORMATION 'SUILD NU•
ARRAY*1 ARRAY#2 1 ARRAY
#3 Cilt of Menifee
MOD OTY 12 NA NA Y BUYER: " AN
PFI
TILT 23• NA' NA- Building Dept �(NN Yr
DATE:
AZIMUTH 1 I76° 1 NA' I NA'
NOV 0 4 'LO'iO REVIEVIED
Received
•'.pproval of these 1
19'-6'ARRAY approval of,i ny viol
20'-4-FLASHING 16'- '
regulations a d ordi,
__ __— __--____ _—___ jobsite until c mplet
f
I i
I I
SOLADECK WIRE
TRANSITION BOX
(UNDER ARRAY)
I I
- 4 _ O
L----�
I I �
I I
I I
PV AC DISCONNECT
EXTERIOR-GARAGE
UTILITY METER 8
MAIN SERVICE PANEL
(VERIFIED BY BUILDER) I ._J
NOTE:DIMENSIONS ARE SHOWN IN PLANE OF ROOF
N
PLAN 2033 ELEVATION B
ORIENTATION 3 LO #44
ORIGINAL BY: DESIREE WILLIAMS I DATE:15.09.25
MEN I FEE HILLS LENNAR:
980 MONTECITO DRIVE,#302 REVIEWED BY:TOM FIDDES I DATE:15.09.25
CORONA,CA 92879 REV.# BY DATE DESCRIPTION
VnaM(3SW
DWG TITLE: PAGE#: SCALE: SITE LOCATION: 4571 Bmadway Street
INDIVIDUAL 29091 GUAVA STREET B..Id.,,CO 803N
PLOT PLAN 1 1/16'= 1'-0' MENIFEE,CA 303.447O300
SYSTEM LAYOUT
MODULE SPECS AND CALCULATIONS INVERTER SPECS AND CALCULATIONS
ITEM NOTE/CALC UNIT DETAIL ITEM NOTE/CALC UNIT DETAIL
LOCATION MENIFEE,CA INV. MAKE INVERTER SPEC ENPHASE
TEMP,AMBIENT HIGH(TMAX) ASHRAE 2% °C 37 INV.MODEL INVERTER SPEC M21S-60-2LL-SZ2-IG
TEMP.AMBIENT LOW(TMIN) ASHRAE EXTR.MIN °C -2 INV.MAX POWER.(WAC MAX) INVERTER SPEC WATTS(40 225
TEMP,MODULE TEST(TTEST) MODULE SPEC °C 25 INV. INPUT V.(Vuc MAX) INVERTER SPEC VOLTS 00 48 .,FEE
TEMP,DELTA LOW(TEELTA) THIN-TTEST °C -27 INV.OUTPUT V.(Vac NOM) INVERTER SPEC VOLTS(AC) 240
MOD. MANUFACTURER MODULE SPEC HYUNDAI INV.OUTPUT FREQUENCY INVERTER SPEC HERTZ= 60 C'T1
MOD.PART NUMBER MODULE SPEC WS-S265RG INV.OUTPUT CURRENT,IAC INVERTER SPEC AMPS(AC) 0.9 G 1 1
MOD. POWER STC(P) MODULE SPEC WATTS WC) 265 INV.PHASE QUANTITY INVERTER SPEC PHASE I y
MOD. POWER PTC MODULE SPEC WATTS 00 238 COMPLIANCE INVERTER SPEC UL1741/IEE
MOD. OPERATING VOLTAGE(VMP) MODULE SPEC VOLTS 00 31.30 INV.GROUNDING INVTER ISOLATED
MOD.OPEN CCT.VOLTAGE(Vac) MODULE SPEC VOLTS 00 38.10 INV.OTY,MAX/BRANCH CCT. INVER.OTYa SPEC c OTY 12
MOD.COEFF.VOLT/TEMP(COEF) MODULE SPEC V7°C -0.114 BRANCH CCT.OUTPUT.IMAXBC I (AC-INV,GTYBC) AMPS(AC) 10.80
MOD.MAX VOLTAGE(VMAXMOD) (Vac+(TD-COEF)) VOLTS 00 41.18 INV.QUANTITY,TOTAL INV.QTYT QTY 12
MOO.OPERATING CURRENT(IMP) MODULE SPEC AMPS(DU 8.50 TOTAL SYSTEM OUTPUT,IMAXTs I(IAC•INV.QTYT) AMPS(AC) 10.80
MOD.SHORT CCT.CURRENT(Isc) MODULE SPEC AMPS 00 9.00
MOD.MAXIMUM CURRENT(IMAX) (Isc•1.25) AMPS 00 11.25
MIN.AMPACITY REQ'D,PER NEC (]MAX•1.25) AMPS(DC) 14.06
SERIES FUSE RATING,MAX MODULE SPEC AMPS 00 IS
ELECTRICAL EQUIPMENT SCHEDULE sshallnot tons
KEY OTY MANUFACTURER MODEL NOTES TRADE )n 0 anY Pf Wsion
I 12 HYUNDAI HIS-S265RG(265W) PV MODULE SOLAR ¢es. This s t ofapl
2 12 ENPHASE M215-60-2LL-S22-IG PVINVERTER SOLAR
3 1 RSTC/SOLADECK 0786-3RS PV ROOF JUNCTION BOX,NEMA 3R SOLAR
4 1 CUTLER-HAMMER DG221URB PV AC DISCONNECT,NEMA 3R.240V.30A SOLAR
5 1 ENPHASE ENVOY PV DATA MONITOR,120V SOLAR
6 I TBD TBD 120V DEDICATED RECEPTACLE FOR ENVOY PV DATA MONITOR SOLAR
7 1 TBD TBD CATS PORT FOR SOLAR PV INTERNET CONNECTION TO HOME NETWORK BOX SOLAR
8 NOTE CUTLER-HAMMER TBD PV BRANCH CIRCUIT BREAKERS:I x 15A-IP(ENVOY) SOLAR
9 NOTF nITI ER-IIAMMER TBD PV PRFAKFR.I x 20A-PP.1 OCATF AT OPPOSITF END OF BUS FROM MAIN BRFAKFR SOLAR
10 T-1-T-8-0i TBD 1 SERVICE PANEL,MIN. 125A BUS I BLDR.ELEC.
II 11 1 TBD TBD I UTILITY METER,IPH,120/Z4UV,200A BLDR.ELEC.
12 11 1 TBD I TBD I GROUNDING ELECTRODE UFER BLDR.ELEC.
CONDUCTOR SIZING CALCULATIONS INTERCONNECTION CALCULATIONS
D CONDITION OF USE(COU): I(AMPACITY•TEMP.DEBATE•FILL DERATE) vs.REO'D(IMAX) ITEM UNIT I PANEL
2)TERMINALS(TERM): AMPACITY AT TERMINALS. ys.REG-D.OHAX• 1.25) PANEL MFR. CUTLER-HAMMER
KEY SIZE CU/AL INSULATION CALL. AMPACITY W/O TEMP. FILL I RESULT I REO'D OCD BUS RATING AMPS 200
TYPE DERATES DERATE DERATE W (A) USED(A) MAIN DISCONNECT AMPS 200
A #12 CU THWN-2 COU 30 0.76 1.0 1 12.80 1 10.80 1 ALLOWED PV PER NEC AMPS 40
TERM 25 135
13.50 20 PV OCPD DEVICE USED AMPS 10
B #0 CU NM-B COU 40 0.91 1.040 10.90
TERM 35 13.50 20
C #10 CU NM-B COU 40 0.91 1.040 10.80
TERM 35 113.50 20
CONDUCTOR SCHEDULE
KEY I CONDUCTORS CU/AL TYPE LOCATION TRADE
A 1-#12 ENGAGE CABLE.1-965.FREE AIR CU TC-ER ARRAY SOLAR
B 1 3410.1-#10 EGC I CU I NM-B(ROMEX) I INTERIOR SOLAR 0 5 II
C 1 3410.1410 EGC I CU I NM-B(ROMEX) I INTERIOR I SOLAR O• C ® M
0 I CAT5E.ETHERNET CABLE I CU I CAT5E I INTERIOR ISOLAR
SEE NOTE 15 10
° ® ( o
8
ISAl1P
G 9
O O 2DO
- Tie
N
G G
1 I I
I BA
ROOF GARAGE
ELECTRICAL DIAGRAM 3.16 KW
LOT#44
ORIGINAL BY: DESIREE WILLIAMS I DATE:15.09.25
LENNAR:
MENIFEE HILLS REVIEWED BY:TOM FIDDES I DATE:15.09.25
980 MONTECITO DRIVE,#302
CORONA.CA 92879 REV.# BY DATE IDESCRIPTION
tit mclste
POLAR
DWG TITLE: PAGE#: SCALE: SITE LOCATION: 4571 BroadWay S1rea1
INDIVIDUAL 29091 GUAVA STREET Boulder,CO 803N
PLOT PLAN 2 NTS MENIFEE.CA 303"7.0300
ELECTRICAL
STRUCTURAL NOTES:
SOLAR CONTRACTOR-
1)ALL PV ROOF ATTACHMENTS WILL BE SPACED ALONG MODULE RACKING RAILS AT NOT GREATER THAN 48'O.C.
2)ALL PV ROOF ATTACHMENTS WILL BE STAGGERED BY ROW AMONGST THE ROOF FRAMING MEMBERS,TO MAXIMUM EXTENT POSSIBLE.
3)ROOF PENETRATIONS ASSOCIATED WITH SOLAR RACKING WILL BE SEALED WITH AN APPROVED SEALANT.
4)SOLADECK WIRE TRANSITION BOX WILL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS. IT WILL BE FLASHED AND SEALED.
5)PV ARRAY WILL BE A MINIMUM OF 3'ABOVE THE COMPOSITE SHINGLE ROOF SURFACE. �� ARTS
6)THE UNIRAC SOLARMOUNT RACKING SYSTEM AND SOLAR PV ARRAY WILL BE INSTALLED ACCORDING TO THE UNIRAC SOLARMOUNT CODE-COMPLIANT INSTALLATION
MANUAL.VERSION 227.3,PUB 140113-ICC,JANUARY 2014.
7)UNIRAC TOP CLAMPS REQUIRE A ONE INCH(I')SPACE BETWEEN PV MODULES.SOLARMOUNT RAILS MUST EXTEND A MINIMUM OF TWO INCHES(21 BEYOND.THE EDGE
OF THE PV ARRAY 7 SUB-ARRAY.
B)UNIRAC SOLARMOUNT REQUIRES THAT A THERMAL EXPANSION GAP BE INSTALLED FOR ANY RAIL LENGTH OF GREATER THAN 40'.
ROOFING CONTRACTOR-
H DISTANCE BETWEEN ARRAY EDGE AND TRANSITION FLASHING(COMPOSITION TO TILE)WILL BE A MINIMUM OF 3'.
2)26 GAUGE INTERLOCKING FLASHING'SIDEWALL'TO BE INSTALLED ALONG THE LENGTH OF THE PV ARRAY AT ROOFING MATERIAL TRANSITION. IT SHALL BE
"ROVED PRIOR TO PV SYSTEM INSTALLATION.
3)PEEL-N-STICK BASE TO BE INSTALLED ONE FOOT 00 OR MORE BEYOND THE EDGE OF THE COMPOSITION SHINGLE,DOWN TO THE ROOF EAVE.PEEL-N-STICK BASE TO
BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS.
4)AREAS UNDER EACH PV ARRAY SHALL BE ROOFED WITH COMPOSITION SHINGLE. COMPOSITION SHINGLE SHALL RUN FROM ABOVE THE PV ARRAY TO THE ROOF EAVE.
5)TILE INSTALLED BELOW THE ARRAY TO BE INSTALLED ABOVE THE COMPOSITION ROOF PER ROOFER SPECIFICATIONS.
6)BIRDSTOP WILL BE INSTALLED AT THE UPPERMOST TRANSITION FROM TILE TO COMPOSITION SHINGLE. BIRDSTOP TO BE SPECIFIED BY ROOFER PRIOR TO It)be ape
INSTALLATION.
the federal,
red lans mt
ELECTRICAL NOTES:
GENFRAL-
U ALL PV EUUIPMEN I WILL HE TESTED AND LISTED FOH ITS USE BY A NATIONALLY RLCUGIJIZED TEST ING LABORATORY WHEEL).
2)THE GROUNDING OF THE PHOTOVOLTAIC SYSTEM SHALL COMPLY WITH THE APPLICABLE VERSION OF THE NEC/CEC.
3)ALL GROUNDING ELECTRODE CONDUCTORS WILL BE INSTALLED IN A CONTINUOUS LENGTH EXCEPT WHERE SPLICED BY AN IRREVERSIBLE CONNECTOR OR EXOTHERMIC
WELD.
4)NON-CURRENT CARRYING METAL PARTS SHALL BE CHECKED FOR PROPER GROUNDING.NOTING THAT TERMINAL LUGS BOLTED ON AN ENCLOSURE'S FINISHED SURFACE
MAY BE ELECTRICALLY INSULATED BECAUSE OF PAINT/FINISH. PAINT/FINISH AT POINT OF CONTACT SHALL BE PROPERLY REMOVED.
5)ROOF PENETRATIONS WILL BE COMPLETED AND SEALED PER APPLICABLE CODE.
6)ALL CONDUCTORS WILL HAVE A 90-C RATING TO ENSURE CODE COMPLIANCE.
SOLAR CONTRACTOR-
7)MODULE CERTIFICATIONS WILL INCLUDE LIL1703.IEC61646.IEC61730.
8)CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS.
9)RACEWAY POINT OF PENETRATION FROM EXTERIOR TO INTERIOR WILL BE SEALED TO PREVENT INGRESS OF WATER AND INSECTS.
10)DC WIRING IS LIMITED TO PV ARRAY FOOTPRINT W/ENPHASE MICRO-INVERTER SYSTEM.
IO MODULE AND ENPHASE WIRING SHALL BE LOCATED AND SECURED UNDER THE ARRAY USING SUITABLE WIRING CLIPS.WIRING SHALL NOT MAKE CONTACT WITH THE
ROOF SURFACE AND SHALL BE MANAGED IN A WORKMAN-LIKE MANNER.
12)EQUIPMENT GROUNDING CONDUCTORS WILL BE SIZED IN ACCORDANCE WITH NEC TABLE 250.122.
13)CONDUCTOR TERMINATIONS WILL BE TORQUED PER DEVICE LISTING,OR MANUFACTURER'S RECOMMENDATIONS.
14)A PV AGGREGATION PANEL(SUB PANEL)WILL NOT BE INCLUDED FOR SYSTEMS WITH ONE BRANCH CIRCUIT.
15)A DEDICATED 120V BRANCH CIRCUIT IS REQUIRED IN MASTER CLOSET(OR EQUIVALENT)FOR ENPHASE ENVOY MONITOR.
SIGNAGE-
16)PV SYSTEMS SHALL BE CLEARLY MARKED IN ACCORDANCE WITH NEC ARTICLE 690 AND OTHER APPLICABLE STATE AND LOCAL CODES.
❑)ALL SAFETY MARKING/PLACARDS SHALL BE PERMANENTLY ATTACHED BY ADHESIVE OR OTHER MECHANICAL MEANS.
10)MARKING/PLACARDS WILL BE METAL OR PLASTIC WITH ENGRAVED OR MACHINE PRINTED LETTERING. BACKGROUND WILL BE RED WITH WHITE CAPITAL LETTERING OF
MINIMUM HEIGHT t
19)ALL WIRING/RACEWAYS/JUNCTION BOXES WILL BE MARKED'PHOTOVOLTAIC POWER SOURCE:OR EQUIVALENT;WIRING/RACEWAYS SHALL BE MARKED EVERY 10'.
BUILDER ELECTRICAL AND SOLAR CONTRACTORS-
20)INSTALLATION SHALL BE COMPLETED IN A NEAT AND WORKMAN-LIKE MANNER.
21)SPACE REQUIREMENTS FOR ALL ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110.26.
ORIGINAL BY: DESIREE WILLIAMS DATE:15.09.25
LENNAR:
MENIFEE HILLS REVIEWED BY: TOM FIDDES DATE:15.09.25
980 MONTECITO DRIVE.#302
CORONA,CA 92879 REV.# BY DATE DESCRIPTION 4 -9
namaste
tow
DWG TITLE: PAGE#: SCALE: SITE LOCATION: 4571 Broadway S"el
INDIVIDUAL 29091 GUAVA STREET BSWdet.CO 80306
PLOT PLAN 3 NTS MENEFEE.CA 303.447.0300
NOTES
CAUTION:
POWER TO THIS BUILDING IS SUPPLIED BY THE ENT
UTILITY AND A SOLAR PV SYSTEM. DISCONNECTS
ARE LOCATED AS SHOWN. r
DA E
'for,or an
e or city
:e kept on If e
S.E[R WIPE
T IT-lox
twoER eRrtan
ad.
N AC ol=MNKT
EXTERIOR-GARAGE
IRRJIV! .T A
MAIN GFNVS'R PulEl
ILRRFIEO 8Y fL8LEP1
SERVICE BY QUALIFIED PERSONNEL ONLY
CONTACT: SUNSTREET ENERGY GROUP
I-877-SLR-POWR
PV POWER SOURCE - AC SPECS
AC OPERATING VOLTAGE: 240 V
AC OPERATING CURRENT: im A
NOTE: SEE MASTER SET FOR ADDITIONAL PLACARD INFORMATION
LENNAR: ORIGINAL BY: DESIREE WILLIAMS DATE:15.09.25
MENIFEE HILLS 980 MONTECITO DRIVE,#302 REVIEWED BY:TOM FIDDES DATE:15.09.25
CORONA.CA 92879 REV.# BY DATE DESCRIPTION
Vncimastd
SOLAR
DWG TITLE: PAGE#: SCALE: SITE LOCATION: 4571 BmaEWay Street
INDIVIDUAL 29091 GUAVA STREET Bauldw.CO 803N
PLOT PLAN 4 NTS MENIFEE.CA 303.447.0300
PLACARDS