Loading...
PMT15-03415 City of Menifee Permit No.: PMT15-03415 29714 HAUN RD. Type: Residential Electrical �ACCELA—> MENIFEE,CA 92586 MENIFEE Date Issued: 11/O6/2015 PERMIT Site Address: 29091 GUAVA ST,MENIFEE, CA 92584 Parcel Number: 333-632-005 Construction Cost: $8,017.20 Existing Use: Proposed Use: Description of SOLAR TR31582-1 MENIFEE HILLS Work: 3.18 KW 12 MODULES LOT 44 Owner Contractor LENNAR HOMES OF CA, INC LENNAR HOMES OF CALIFORNIA INC 980 MONTECITO DR#302 25 ENTERPRISE CORONA, CA 92879 ALISO VIEJO, CA 92656 Applicant Phone:9493498269 JEREMIAH ACAYTURRI License Number:728102 LENNAR HOMES OF CALIFORNIA INC 25 ENTERPRISE ALISO VIEJO,CA 92656 Fee Descriptlon QQtt Amount!$) Solar, Residential or Small Commercial 1 252.00 Building Permit Issuance 1 27.00 GREEN FEE 1 1.00 SMIP RESIDENTIAL 1 2.00 General Plan Maintenance Fee-Electrical 1 12.60 $294.60 The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and specifications or from preventing builiding operations being carded on thereunder when in violation of the Building Code or of any other ordinance of City of Menifee.Except as otherwise stated,a permit for construction under which no work is commenced within six months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be forfeited. AA_Bldg_Permil_Template.rpt Page 1 of 1 PERMIT/PLANBUILDING & SAFETY APPLICATION Menifee milt DATE 10/28/2015 PERMIT/PLAN CHECK NUMBER 1' 1" T5- l`5 TYPE: ❑COMMERCIAL ❑✓ RESIDENTIAL ❑MULTI-FAMILY ❑MOBILE HOME ❑POOL/SPA SIGN SUBTYPE: ❑✓ ADDITION ❑ALTERATION []DEMOLITION ❑ELECTRICAL [-]MECHANICAL ❑NEW []PLUMBING ❑RE-ROOF-NUMBER OF SQUARES DESCRIPTION OF WORK SOLAR PERMIT-Plan 2033 3.18 kW/12 PCS Master Solar Plan#PMT14-00706 PROJECT ADDRESS 29091 Guava St, Menifee, CA 92584 ASSESSOR'S PARCEL NUMBER 333-632-005 LOT 44 TRACT 31582-1 PROPERTY OWNER'S NAME Lennar Homes of California, Inc. ADDRESS 980 Montecito Dr., Suite 302 PHONE (951)817-3680 EMAIL leremiah.ecayturri@lennar.com APPLICANT NAME Lennar Homes of California, Inc. ADDRESS 980 Montecito Dr.,Suite 302, Carona,CA 92879 PHONE (951)817-3680 EMAIL leremiah.acaytum@lennar.com CONTRACTOR'S NAME Lennar Homes of California, Inc. OWNER BUILDER? ❑✓ YES❑NO BUSINESS NAME Lennar Homes of California, Inc. ADDRESS 980 Montecito Dr.,Suite 302,Corona,CA 92879 PHONE (951)817-3680 EMAIL leremiah.acaytumi@lennarcom CONTRACTOR'S STATE LIC NUMBER 728102 LICENSE CLASSIFICATION A&B VALUATION$ $8,017.20 SO.FT L SO FT APPLICANT'S SIGNATURE DATE UYSTAFF USE ONLY DEPARTMENT DISTRIBUTION aQ y` iJ CITY OF MENIFEE BUSINESS LICENSE NUMBER BUILDING PLANNING ENGINEERING FIRE GREEN , sMIP INVOICE G �Q PAIDAMOUNT AMOUNT _ ` O CA O SH OCHELK# CREDIT CARD VISA/MC PLAN CHECK FEES PAID AMOUNT O CASH O CHECK# O CREDITCARD VISA/MC OWNER BUILDER VERIFIED OYES O NO DL NUMBER NOTARIZED LETTER O YES O NO City of Menifee Building&Safety Department 29714 Houn Rd. Menifee, CA 92586 951-672-6777 www.citycfinenifee.us Inspection Request Line 951-246-6213 SYSTEM INFORMATION BUYER ACKNOWLEDGES THAT THE SOLAR MODULES TO BE INSTALLED ITEM OTY MFR. MODEL ON THE ROOF OF THE HOME WILL BE SUBSTANTIALLY IN THE SYSTEM SIZE 3.16 KW LOCATIONS INDICATED BY THE ILLUSTRATION. MODULE 1 12 PCS. HYUNDAI I HIS-SZ65RG(265W) BUYER: / INVERTER 1 12 PCS.1 ENPHASE I M215-60-2LL-S22-IG 1 r F M ROOF TYPE I TILE W/COMPOSITE SHINGLE UNDER ARRAY DATE: /+ SUB-ARRAY INFORMATION 'SUILD NU• ARRAY*1 ARRAY#2 1 ARRAY #3 Cilt of Menifee MOD OTY 12 NA NA Y BUYER: " AN PFI TILT 23• NA' NA- Building Dept �(NN Yr DATE: AZIMUTH 1 I76° 1 NA' I NA' NOV 0 4 'LO'iO REVIEVIED Received •'.pproval of these 1 19'-6'ARRAY approval of,i ny viol 20'-4-FLASHING 16'- ' regulations a d ordi, __ __— __--____ _—___ jobsite until c mplet f I i I I SOLADECK WIRE TRANSITION BOX (UNDER ARRAY) I I - 4 _ O L----� I I � I I I I PV AC DISCONNECT EXTERIOR-GARAGE UTILITY METER 8 MAIN SERVICE PANEL (VERIFIED BY BUILDER) I ._J NOTE:DIMENSIONS ARE SHOWN IN PLANE OF ROOF N PLAN 2033 ELEVATION B ORIENTATION 3 LO #44 ORIGINAL BY: DESIREE WILLIAMS I DATE:15.09.25 MEN I FEE HILLS LENNAR: 980 MONTECITO DRIVE,#302 REVIEWED BY:TOM FIDDES I DATE:15.09.25 CORONA,CA 92879 REV.# BY DATE DESCRIPTION VnaM(3SW DWG TITLE: PAGE#: SCALE: SITE LOCATION: 4571 Bmadway Street INDIVIDUAL 29091 GUAVA STREET B..Id.,,CO 803N PLOT PLAN 1 1/16'= 1'-0' MENIFEE,CA 303.447O300 SYSTEM LAYOUT MODULE SPECS AND CALCULATIONS INVERTER SPECS AND CALCULATIONS ITEM NOTE/CALC UNIT DETAIL ITEM NOTE/CALC UNIT DETAIL LOCATION MENIFEE,CA INV. MAKE INVERTER SPEC ENPHASE TEMP,AMBIENT HIGH(TMAX) ASHRAE 2% °C 37 INV.MODEL INVERTER SPEC M21S-60-2LL-SZ2-IG TEMP.AMBIENT LOW(TMIN) ASHRAE EXTR.MIN °C -2 INV.MAX POWER.(WAC MAX) INVERTER SPEC WATTS(40 225 TEMP,MODULE TEST(TTEST) MODULE SPEC °C 25 INV. INPUT V.(Vuc MAX) INVERTER SPEC VOLTS 00 48 .,FEE TEMP,DELTA LOW(TEELTA) THIN-TTEST °C -27 INV.OUTPUT V.(Vac NOM) INVERTER SPEC VOLTS(AC) 240 MOD. MANUFACTURER MODULE SPEC HYUNDAI INV.OUTPUT FREQUENCY INVERTER SPEC HERTZ= 60 C'T1 MOD.PART NUMBER MODULE SPEC WS-S265RG INV.OUTPUT CURRENT,IAC INVERTER SPEC AMPS(AC) 0.9 G 1 1 MOD. POWER STC(P) MODULE SPEC WATTS WC) 265 INV.PHASE QUANTITY INVERTER SPEC PHASE I y MOD. POWER PTC MODULE SPEC WATTS 00 238 COMPLIANCE INVERTER SPEC UL1741/IEE MOD. OPERATING VOLTAGE(VMP) MODULE SPEC VOLTS 00 31.30 INV.GROUNDING INVTER ISOLATED MOD.OPEN CCT.VOLTAGE(Vac) MODULE SPEC VOLTS 00 38.10 INV.OTY,MAX/BRANCH CCT. INVER.OTYa SPEC c OTY 12 MOD.COEFF.VOLT/TEMP(COEF) MODULE SPEC V7°C -0.114 BRANCH CCT.OUTPUT.IMAXBC I (AC-INV,GTYBC) AMPS(AC) 10.80 MOD.MAX VOLTAGE(VMAXMOD) (Vac+(TD-COEF)) VOLTS 00 41.18 INV.QUANTITY,TOTAL INV.QTYT QTY 12 MOO.OPERATING CURRENT(IMP) MODULE SPEC AMPS(DU 8.50 TOTAL SYSTEM OUTPUT,IMAXTs I(IAC•INV.QTYT) AMPS(AC) 10.80 MOD.SHORT CCT.CURRENT(Isc) MODULE SPEC AMPS 00 9.00 MOD.MAXIMUM CURRENT(IMAX) (Isc•1.25) AMPS 00 11.25 MIN.AMPACITY REQ'D,PER NEC (]MAX•1.25) AMPS(DC) 14.06 SERIES FUSE RATING,MAX MODULE SPEC AMPS 00 IS ELECTRICAL EQUIPMENT SCHEDULE sshallnot tons KEY OTY MANUFACTURER MODEL NOTES TRADE )n 0 anY Pf Wsion I 12 HYUNDAI HIS-S265RG(265W) PV MODULE SOLAR ¢es. This s t ofapl 2 12 ENPHASE M215-60-2LL-S22-IG PVINVERTER SOLAR 3 1 RSTC/SOLADECK 0786-3RS PV ROOF JUNCTION BOX,NEMA 3R SOLAR 4 1 CUTLER-HAMMER DG221URB PV AC DISCONNECT,NEMA 3R.240V.30A SOLAR 5 1 ENPHASE ENVOY PV DATA MONITOR,120V SOLAR 6 I TBD TBD 120V DEDICATED RECEPTACLE FOR ENVOY PV DATA MONITOR SOLAR 7 1 TBD TBD CATS PORT FOR SOLAR PV INTERNET CONNECTION TO HOME NETWORK BOX SOLAR 8 NOTE CUTLER-HAMMER TBD PV BRANCH CIRCUIT BREAKERS:I x 15A-IP(ENVOY) SOLAR 9 NOTF nITI ER-IIAMMER TBD PV PRFAKFR.I x 20A-PP.1 OCATF AT OPPOSITF END OF BUS FROM MAIN BRFAKFR SOLAR 10 T-1-T-8-0i TBD 1 SERVICE PANEL,MIN. 125A BUS I BLDR.ELEC. II 11 1 TBD TBD I UTILITY METER,IPH,120/Z4UV,200A BLDR.ELEC. 12 11 1 TBD I TBD I GROUNDING ELECTRODE UFER BLDR.ELEC. CONDUCTOR SIZING CALCULATIONS INTERCONNECTION CALCULATIONS D CONDITION OF USE(COU): I(AMPACITY•TEMP.DEBATE•FILL DERATE) vs.REO'D(IMAX) ITEM UNIT I PANEL 2)TERMINALS(TERM): AMPACITY AT TERMINALS. ys.REG-D.OHAX• 1.25) PANEL MFR. CUTLER-HAMMER KEY SIZE CU/AL INSULATION CALL. AMPACITY W/O TEMP. FILL I RESULT I REO'D OCD BUS RATING AMPS 200 TYPE DERATES DERATE DERATE W (A) USED(A) MAIN DISCONNECT AMPS 200 A #12 CU THWN-2 COU 30 0.76 1.0 1 12.80 1 10.80 1 ALLOWED PV PER NEC AMPS 40 TERM 25 135 13.50 20 PV OCPD DEVICE USED AMPS 10 B #0 CU NM-B COU 40 0.91 1.040 10.90 TERM 35 13.50 20 C #10 CU NM-B COU 40 0.91 1.040 10.80 TERM 35 113.50 20 CONDUCTOR SCHEDULE KEY I CONDUCTORS CU/AL TYPE LOCATION TRADE A 1-#12 ENGAGE CABLE.1-965.FREE AIR CU TC-ER ARRAY SOLAR B 1 3410.1-#10 EGC I CU I NM-B(ROMEX) I INTERIOR SOLAR 0 5 II C 1 3410.1410 EGC I CU I NM-B(ROMEX) I INTERIOR I SOLAR O• C ® M 0 I CAT5E.ETHERNET CABLE I CU I CAT5E I INTERIOR ISOLAR SEE NOTE 15 10 ° ® ( o 8 ISAl1P G 9 O O 2DO - Tie N G G 1 I I I BA ROOF GARAGE ELECTRICAL DIAGRAM 3.16 KW LOT#44 ORIGINAL BY: DESIREE WILLIAMS I DATE:15.09.25 LENNAR: MENIFEE HILLS REVIEWED BY:TOM FIDDES I DATE:15.09.25 980 MONTECITO DRIVE,#302 CORONA.CA 92879 REV.# BY DATE IDESCRIPTION tit mclste POLAR DWG TITLE: PAGE#: SCALE: SITE LOCATION: 4571 BroadWay S1rea1 INDIVIDUAL 29091 GUAVA STREET Boulder,CO 803N PLOT PLAN 2 NTS MENIFEE.CA 303"7.0300 ELECTRICAL STRUCTURAL NOTES: SOLAR CONTRACTOR- 1)ALL PV ROOF ATTACHMENTS WILL BE SPACED ALONG MODULE RACKING RAILS AT NOT GREATER THAN 48'O.C. 2)ALL PV ROOF ATTACHMENTS WILL BE STAGGERED BY ROW AMONGST THE ROOF FRAMING MEMBERS,TO MAXIMUM EXTENT POSSIBLE. 3)ROOF PENETRATIONS ASSOCIATED WITH SOLAR RACKING WILL BE SEALED WITH AN APPROVED SEALANT. 4)SOLADECK WIRE TRANSITION BOX WILL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS. IT WILL BE FLASHED AND SEALED. 5)PV ARRAY WILL BE A MINIMUM OF 3'ABOVE THE COMPOSITE SHINGLE ROOF SURFACE. �� ARTS 6)THE UNIRAC SOLARMOUNT RACKING SYSTEM AND SOLAR PV ARRAY WILL BE INSTALLED ACCORDING TO THE UNIRAC SOLARMOUNT CODE-COMPLIANT INSTALLATION MANUAL.VERSION 227.3,PUB 140113-ICC,JANUARY 2014. 7)UNIRAC TOP CLAMPS REQUIRE A ONE INCH(I')SPACE BETWEEN PV MODULES.SOLARMOUNT RAILS MUST EXTEND A MINIMUM OF TWO INCHES(21 BEYOND.THE EDGE OF THE PV ARRAY 7 SUB-ARRAY. B)UNIRAC SOLARMOUNT REQUIRES THAT A THERMAL EXPANSION GAP BE INSTALLED FOR ANY RAIL LENGTH OF GREATER THAN 40'. ROOFING CONTRACTOR- H DISTANCE BETWEEN ARRAY EDGE AND TRANSITION FLASHING(COMPOSITION TO TILE)WILL BE A MINIMUM OF 3'. 2)26 GAUGE INTERLOCKING FLASHING'SIDEWALL'TO BE INSTALLED ALONG THE LENGTH OF THE PV ARRAY AT ROOFING MATERIAL TRANSITION. IT SHALL BE "ROVED PRIOR TO PV SYSTEM INSTALLATION. 3)PEEL-N-STICK BASE TO BE INSTALLED ONE FOOT 00 OR MORE BEYOND THE EDGE OF THE COMPOSITION SHINGLE,DOWN TO THE ROOF EAVE.PEEL-N-STICK BASE TO BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS. 4)AREAS UNDER EACH PV ARRAY SHALL BE ROOFED WITH COMPOSITION SHINGLE. COMPOSITION SHINGLE SHALL RUN FROM ABOVE THE PV ARRAY TO THE ROOF EAVE. 5)TILE INSTALLED BELOW THE ARRAY TO BE INSTALLED ABOVE THE COMPOSITION ROOF PER ROOFER SPECIFICATIONS. 6)BIRDSTOP WILL BE INSTALLED AT THE UPPERMOST TRANSITION FROM TILE TO COMPOSITION SHINGLE. BIRDSTOP TO BE SPECIFIED BY ROOFER PRIOR TO It)be ape INSTALLATION. the federal, red lans mt ELECTRICAL NOTES: GENFRAL- U ALL PV EUUIPMEN I WILL HE TESTED AND LISTED FOH ITS USE BY A NATIONALLY RLCUGIJIZED TEST ING LABORATORY WHEEL). 2)THE GROUNDING OF THE PHOTOVOLTAIC SYSTEM SHALL COMPLY WITH THE APPLICABLE VERSION OF THE NEC/CEC. 3)ALL GROUNDING ELECTRODE CONDUCTORS WILL BE INSTALLED IN A CONTINUOUS LENGTH EXCEPT WHERE SPLICED BY AN IRREVERSIBLE CONNECTOR OR EXOTHERMIC WELD. 4)NON-CURRENT CARRYING METAL PARTS SHALL BE CHECKED FOR PROPER GROUNDING.NOTING THAT TERMINAL LUGS BOLTED ON AN ENCLOSURE'S FINISHED SURFACE MAY BE ELECTRICALLY INSULATED BECAUSE OF PAINT/FINISH. PAINT/FINISH AT POINT OF CONTACT SHALL BE PROPERLY REMOVED. 5)ROOF PENETRATIONS WILL BE COMPLETED AND SEALED PER APPLICABLE CODE. 6)ALL CONDUCTORS WILL HAVE A 90-C RATING TO ENSURE CODE COMPLIANCE. SOLAR CONTRACTOR- 7)MODULE CERTIFICATIONS WILL INCLUDE LIL1703.IEC61646.IEC61730. 8)CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS. 9)RACEWAY POINT OF PENETRATION FROM EXTERIOR TO INTERIOR WILL BE SEALED TO PREVENT INGRESS OF WATER AND INSECTS. 10)DC WIRING IS LIMITED TO PV ARRAY FOOTPRINT W/ENPHASE MICRO-INVERTER SYSTEM. IO MODULE AND ENPHASE WIRING SHALL BE LOCATED AND SECURED UNDER THE ARRAY USING SUITABLE WIRING CLIPS.WIRING SHALL NOT MAKE CONTACT WITH THE ROOF SURFACE AND SHALL BE MANAGED IN A WORKMAN-LIKE MANNER. 12)EQUIPMENT GROUNDING CONDUCTORS WILL BE SIZED IN ACCORDANCE WITH NEC TABLE 250.122. 13)CONDUCTOR TERMINATIONS WILL BE TORQUED PER DEVICE LISTING,OR MANUFACTURER'S RECOMMENDATIONS. 14)A PV AGGREGATION PANEL(SUB PANEL)WILL NOT BE INCLUDED FOR SYSTEMS WITH ONE BRANCH CIRCUIT. 15)A DEDICATED 120V BRANCH CIRCUIT IS REQUIRED IN MASTER CLOSET(OR EQUIVALENT)FOR ENPHASE ENVOY MONITOR. SIGNAGE- 16)PV SYSTEMS SHALL BE CLEARLY MARKED IN ACCORDANCE WITH NEC ARTICLE 690 AND OTHER APPLICABLE STATE AND LOCAL CODES. ❑)ALL SAFETY MARKING/PLACARDS SHALL BE PERMANENTLY ATTACHED BY ADHESIVE OR OTHER MECHANICAL MEANS. 10)MARKING/PLACARDS WILL BE METAL OR PLASTIC WITH ENGRAVED OR MACHINE PRINTED LETTERING. BACKGROUND WILL BE RED WITH WHITE CAPITAL LETTERING OF MINIMUM HEIGHT t 19)ALL WIRING/RACEWAYS/JUNCTION BOXES WILL BE MARKED'PHOTOVOLTAIC POWER SOURCE:OR EQUIVALENT;WIRING/RACEWAYS SHALL BE MARKED EVERY 10'. BUILDER ELECTRICAL AND SOLAR CONTRACTORS- 20)INSTALLATION SHALL BE COMPLETED IN A NEAT AND WORKMAN-LIKE MANNER. 21)SPACE REQUIREMENTS FOR ALL ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110.26. ORIGINAL BY: DESIREE WILLIAMS DATE:15.09.25 LENNAR: MENIFEE HILLS REVIEWED BY: TOM FIDDES DATE:15.09.25 980 MONTECITO DRIVE.#302 CORONA,CA 92879 REV.# BY DATE DESCRIPTION 4 -9 namaste tow DWG TITLE: PAGE#: SCALE: SITE LOCATION: 4571 Broadway S"el INDIVIDUAL 29091 GUAVA STREET BSWdet.CO 80306 PLOT PLAN 3 NTS MENEFEE.CA 303.447.0300 NOTES CAUTION: POWER TO THIS BUILDING IS SUPPLIED BY THE ENT UTILITY AND A SOLAR PV SYSTEM. DISCONNECTS ARE LOCATED AS SHOWN. r DA E 'for,or an e or city :e kept on If e S.E[R WIPE T IT-lox twoER eRrtan ad. N AC ol=MNKT EXTERIOR-GARAGE IRRJIV! .T A MAIN GFNVS'R PulEl ILRRFIEO 8Y fL8LEP1 SERVICE BY QUALIFIED PERSONNEL ONLY CONTACT: SUNSTREET ENERGY GROUP I-877-SLR-POWR PV POWER SOURCE - AC SPECS AC OPERATING VOLTAGE: 240 V AC OPERATING CURRENT: im A NOTE: SEE MASTER SET FOR ADDITIONAL PLACARD INFORMATION LENNAR: ORIGINAL BY: DESIREE WILLIAMS DATE:15.09.25 MENIFEE HILLS 980 MONTECITO DRIVE,#302 REVIEWED BY:TOM FIDDES DATE:15.09.25 CORONA.CA 92879 REV.# BY DATE DESCRIPTION Vncimastd SOLAR DWG TITLE: PAGE#: SCALE: SITE LOCATION: 4571 BmaEWay Street INDIVIDUAL 29091 GUAVA STREET Bauldw.CO 803N PLOT PLAN 4 NTS MENIFEE.CA 303.447.0300 PLACARDS