Loading...
PMT15-03414 City of Menifee Permit No.: PMT15-03414 29714 HAUN RD. Type: Residential Electrical �XCCEL/4? MENIFEE, CA 92586 MENIFEE Date Issued: 1110612015 PERMIT Site Address: 29079 GUAVA ST, MENIFEE,CA 92584 Parcel Number: 333-632-004 Construction Cost: $9,353.40 Existing Use: Proposed Use: Description of SOLAR TR-31582-1 MENIFEE HILLS Work: 3.71 KW 14 MODULES LOT 43 Owner Contractor LENNAR HOMES OF CA, INC LENNAR HOMES OF CALIFORNIA INC 980 MONTECITO DR#302 25 ENTERPRISE CORONA,CA 92879 ALISO VIEJO, CA 92656 Applicant Phone:9493498269 JEREMIAH ACAYTURRI License Number:728102 LENNAR HOMES OF CALIFORNIA INC 25 ENTERPRISE ALISO VIEJO, CA 92656 Fee Description Qtv Amount f51 Solar, Residential or Small Commercial 1 252.00 Building Permit Issuance 1 27.00 GREEN FEE 1 1.00 SMIP RESIDENTIAL 1 2.00 General Plan Maintenance Fee-Electrical 1 12.60 $294.60 The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and specifications or from preventing builiding operations being carded on thereunder when in violation of the Building Code or of any other ordinance of City of Menifee.Except as otherwise stated,a permit for construction under which no work is commenced within six months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be forfeited. AA_Bldg_Permil_Template.rpt Page 1 of 1 PERMIT/PLANBUILDING & SAFETY APPLICATION Menifee DATE 10/28/2015 PERMIT/PLAN CHECK NUMBER TYPE: ❑COMMERCIAL ❑✓ RESIDENTIAL ❑MULTI-FAMILY ❑MOBILEHOME ❑POOL/SPA ❑SIGN SUBTYPE: ❑✓ ADDITION [—]ALTERATION ❑DEMOLITION [—]ELECTRICAL ❑MECHANICAL [—]NEW ❑PLUMBING ❑RE-ROOF-NUMBER OF SQUARES DESCRIPTION OF WORK SOLAR PERMIT-Plan 2809 3.71 kW/14 PCS Master Solar Plan#PMT14-00706 PROJECT ADDRESS 29079 Guava St, Menifee,CA 92584 ASSESSOR'S PARCEL NUMBER 333-632-004 LOT 43 TRACT 31582-1 PROPERTY OWNER'S NAME Lennar Homes of California, Inc. ADDRESS 980 Montecito Dr.,Suite 302 PHONE (951)817-3680 EMAIL )eremiah.acayturri@lennar.com APPLICANT NAME Lennar Homes of California, Inc. ADDRESS 980 Montecito Dr.,Suite 302,Corona,CA 92879 PHONE (951)817-3680 EMAIL leremiah.acayturri@lennar.com CONTRACTOR'S NAME Lennar Homes of California, Inc. OWNER BUILDER? ❑✓ YES❑NO BUSINESS NAME Lennar Homes of California, Inc. ADDRESS 980 Montecito Dr.,Suite 302, Corona,CA 92879 PHONE (951)817-3680 EMAIL jeremiah.acaytur6@lennar.com CONTRACTOR'S STATE LIC NUMBER 728102 LICENSE CLASSIFICATION A&B VALUATION$ $9,353.40 L SQ_ FT �f APPLICANT'S SIGNATURE -� DATE I0 `S DEPARTMENT DISTRIBUTION CITY OF(MENIFEE BUSINESS LICENSE NUMBER BUILDING PLANNING ENGINEERING FIRE GREEN l SMIP vy4" INVOICE V PAID AMOUNT n AMOUNT CASH OCHECK# OCREDITCARD VISA/MC PLAN CHECK FEES PAID AMOUNT OCASH OCHECK# 0 CREDIT CARD VISA/MC OWNER BUILDER VERIFIED OYES O No DL NUMBER NOTARIZED LETTER O YES O NO City of Menifee Building&Safety Department 29714 Haun Rd. Menifee, CA 92585 951-672-6777 www.cityofinenifee.us Inspection Request Line 951-246-6213 SYSTEM INFORMATION BUYER ACKNOWLEDGES THAT THE SOLAR MODULES TO BE INSTALLED ITEM OTV MFR. MODEL ON THE ROOF OF THE HOME WILL BE SUBSTANTIALLY IN THE SYSTEM SIZE 1 .71 KW I LOCATIONS INDICATED BY THE ILLUSTRATION. MODULE 14 PCS. HYUNDAI I HIS-S265RG(265W) I BUYER: INVERTER 1 14 PCS. ENPHASE 1 4215-60-2LL-S22-IG ROOF TYPE I TILE W/COMPOSITE SHINGLE UNDER ARRAY DATE: SUB-ARRAY INFORMATION ARRAY#1 ARRAY#2 1 ARRAY#3 MOD OTY 1 14 1 NA NA BUYER: TILT 23° NA' aw• City of Menifee t 1� OF NItI AZIMUTH IBI° NA' NA- Building Dept DATE: r:OTIM G A NOV 0 4 2015 PLAN AN ARM Received REVIEW D0 `Approval ofth sepla 22'-9'ARRAY a rova , 9'-7jf' 23'-7'FLASHING FP I of anj violatl regulations and ordina ——— —— jobsite until con iplefloi t SOLADECK WIRE TRANSITION BOX t (UNDER ARRAY) I V � I PV AC DISCONNECT L EXTERIOR-GARAGE UTILITY METER B —— MAIN SERVICE PANEL t—— _ _—_ —J (VERIFIED BY BUILDER) C amp NOTE:DIMENSIONS ARE SHOWN IN PLANE OF ROOF N �w PLAN"09 ELEVATION C-REVERSE RIENTATION 3 L ORIGINAL BY: DESIREE WILLIAMS DATE:15.09.25 MEN FEE HILLS LENNAR: 980 MONTECITO DRIVE,#302 REVIEWED BY:TOM FIDDES DATE:15.09.25 CORONA,CA 92879 REV.# BY DATE DESCRIPTION namashd DWG TITLE: PAGE#: SCALE: SITE LOCATION: 4571 Broaftay SVeet INDIVIDUAL 29079 GUAVA STREET Boulder,GO W304 PLOT PLAN 1 1/16-=1'-0' MENIFEE.CA 303.447.0300 SYSTEM LAYOUT MODULE SPECS AND CALCULATIONS INVERTER SPECS AND CALCULATIONS ITEM NOTE/CALC UNIT DETAIL ITEM NOTE/CALC I UNIT DETAIL LOCATION MENIFEE.CA INV.MAKE INVERTER SPEC ENPHASE TEMP,AMBIENT HIGH(TMAX) ASHRAE 2% °C 37 INV.MODEL INVERTER SPEC M215-60-2LL-S22-IG TEMP,AMBIENT LOW(THIN) ASHRAE EXTR.MIN °C -2 INV.MAX POWER,(WAC MAX) INVERTER SPEC WATTS(AC) 225 TEMP.MODULE TEST(TTEST) MODULE SPEC •C 25 INV. INPUT V.(VDC MAX) INVERTER SPEC VOLTS(DD) 48 TEMP.DELTA LOW(TOEETA) TMIN-TTEST °C -27 INV.OUTPUT V.(VAC NOM) INVERTER SPEC VOLTS(AC) 240 MOD. MANUFACTURER MODULE SPEC HYUNDAI INV.OUTPUT FREQUENCY INVERTER SPEC HERTZ 60 MOD.PART NUMBER MODULE SPEC HIS-S265RG INV.OUTPUT CURRENT,IAC INVERTER SPEC AMPS(AC) 0.9 MOD.POWER STC(P) MODULE SPEC WATTS(DD) 265 INV.PHASE QUANTITY INVERTER SPEC PHASE I MOD.POWER PTC MODULE SPEC WATTS(DC) 238 COMPLIANCE INVERTER SPEC UL1741/IEEE1547 MOD.OPERATING VOLTAGE(VMP) MODULE SPEC VOLTS(DC) 31.30 INV. GROUNDING INVERTER SPEC ISOLATED MOD.OPEN CCT.VOLTAGE(Vac) MODULE SPEC VOLTS(DC) 39.10 INV.QTY.MAX/BRANCH CCT. NVATYBc QTY 14 I MOD.COEFF.VOLT/TEMP(COEF) MODULE SPEC V/°L -0.114 BRANCH CCT. OUTPUT, IMAXBC OACINV.OTYBU AMPS(AC) 12.60 MOD. MAX VOLTAGE(VMAXMOD) (Voc♦(TD•COEF)) VOLTS(DO 41.18 INV.QUANTITY,TOTAL INV.OTVT OTY 14 CT�I MOD.OPERATING CURRENT(IMP) MODULE SPEC AMPS(DC) 8.50 TOTAL SYSTEM OUTPUT,IMAXTS (IAC•INV.QTYT) AMPS(AC) 12.60 L I MOD.SHORT CCT.CURRENT(Isc) MODULE SPEC AMPS(DC) 9.00 •/(f1 L MOD. MAXIMUM CURRENT(IMAX) (Isc• 1.25) AMPS(DC) 11.25 MIN.AMPACITY REO'D,PER NEC (WAX- 1.25) AMPS(DC) 14.06 SERIES FUSE RATING,MAX MODULE SPEC AMPS(DC) 15 ELECTRICAL EQUIPMENT SCHEDULE KEY OTY MANUFACTURER MODEL NOTES TRADE 1 14 HYUNDAI HIS-S265RG(265W) PV MODULE SOLAR 2 14 ENPHASE M215-60-2LL-S22-IG PVINVERTER SOLAR ° 3 1 RSTC/SOLADECK 0786-3R5 PV ROOF JUNCTION BOX.NEMA 3R SOLAR 4 1 CUTLER-HAMMER DG221URB PV AC DISCONNECT,NEMA 3R.24OV,30A SOLAR 5 1 ENPHASE ENVOY PV DATA MONITOR, 120V SOLAR :hall nol he cot 6 1 TBD TBD P 120V DEDICATED RECEPTACLE FOR ENVOY PV DATA MONITOR SOLAR 1 . 7 1 TBD TBD CATS PORT FOR SOLAR PV INTERNET CONNECTION TO HOME NETWORK BOX SOLAR of any r rUV1510 8 NOTE CUTLER-HAMMER TBD PV BRANCH CIRCUIT BREAKERS; I X 15A-IP(ENVOY) SOLAR �$, This et of a 9 NOTF CUTI FR IIAMMFR TPD PV BRFAKFR. I r. 2n1. 27.1 n-t Tr AT OPPOSITF 1-tin nF RUS FROM MAIN RRFAKFP SOLAR 10 1 TBD TBD SERVICE PANEL.MIN. 125A BUS BLDR.ELEC. II TBD TBD UTILITY METER,IPH.120/24OV.200A BLDR.ELEC. I2 I TBD TBD GROUNDING ELECTRODE UFER BLDR.ELEC. CONDUCTOR SIZING CALCULATIONS INTERCONNECTION CALCULATIONS 1)CONDITION OF USE(COU): I (AMPACITY' TEMP.DERATE -FILL DERATE) VS.REG'D(IMAX) ITEM UNIT PANEL 2)TERMINALS(TERM: I AMPACITY AT TERMINALS. Vs.REG'D.(IMAX•1.25) PANEL MFR. CUTLER-HAMMER KEY SIZE CU/AL INSULATION CALC' AMPACITY W/O TEMP. FILL RESULT REQ'D OCD BUS RATING AMPS 200 TYPE DERATES DERATE DERATE (A) (A) USED(A) MAIN DISCONNECT AMPS 200 A #12 CU THWN-2 COU 30 0.76 1.0 22.80 12.60 ALLOWED PV PER NEC AMPS 40 TERM 25 25 15.75 20 PV OCPD DEVICE USED AMPS 20 B #10 CU NM-B COU 40 0.91 I.0 36.40 12.60 TERM 35 35 15.75 20 L *10 CU NM-B COU 40 0.91 1.0 36.40 12.60 TERM 35 1 1 35 15.75 20 CONDUCTOR SCHEDULE KEY CONDUCTORS 1 CU/AL 1 TYPE LOCATION TRADE q I I-#12 ENGAGE CABLE,146G.FREE AIR I CU I TC-ER I ARRAY SOLAR B 1 3410,1-910 EGC I CU I NM-B(ROMEX) INTERIOR I SOLAR C 1 3410.1410 EGC I CU I NM-B(ROMEX) INTERIOR I SOLAR 0 I CAT5E.ETHERNET CABLE I CU I CAT5E I INTERIOR I SOLAR 5 A 11 Q• o • I O- SEE NOTE 15 IO © 110 O O G N G G� A B C To- ROOF 1 I I EXTERIOR-GARAGE 1 ELECTRICAL DIAGRAM 3.71 KW LOT#43 ORIGINAL BY: DESIREE WILLIAMS I DATE:15.09.25 MENIFEE HILLS LENNAR: 980 REVIEWED BY:TOM FIDDES DATE:15.09.25 CORONNA.A.C LA A 92879 DRIVE,#302 REV.# BY DATE I DESCRIPTION narnasbe - V SOLAR DWG TITLE: PAGE#: I SCALE: SITE LOCATION: 4571 BroaA ay Steel INDIVIDUAL 29079 GUAVA STREET BDWDer.CO 80304 PLOT PLAN 2 NTS MENIFEE,CA 303.447.0300 ELECTRICAL STRUCTURAL NOTES: SOLAR CONTRACTOR- 0 ALL PV ROOF ATTACHMENTS WILL BE SPACED ALONG MODULE RACKING RAILS AT NOT GREATER THAN 48.O.C. 2)ALL PV ROOF ATTACHMENTS WILL BE STAGGERED BY ROW AMONGST THE ROOF FRAMING MEMBERS,TO MAXIMUM EXTENT POSSIBLE. 3)ROOF PENETRATIONS ASSOCIATED WITH SOLAR RACKING WILL BE SEALED WITH AN APPROVED SEALANT. 4)SOLADECK WIRE TRANSITION BOX WILL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS.IT WILL BE FLASHED AND SEALED. 5)PV ARRAY WILL BE A MINIMUM OF 3'ABOVE THE COMPOSITE SHINGLE ROOF SURFACE. 6)THE UNIRAC SOLARMOUNT RACKING SYSTEM AND SOLAR PV ARRAY WILL BE INSTALLED ACCORDING TO THE UNIRAC SOLARMOUNT CODE-COMPLIANT INSTALLATION MANUAL.VERSION 227.3,PUB 140113-ICC,JANUARY 2014. 7)UNIRAC TOP CLAMPS REQUIRE A ONE INCH(1')SPACE BETWEEN PV MODULES. SOLARMOUNT RAILS MUST EXTEND A MINIMUM OF TWO INCHES(29 BEYOND THE EDGE OF THE PV ARRAY/SUB-ARRAY. �[ 8)UNIRAC SOLARMOUNT REQUIRES THAT A THERMAL EXPANSION GAP BE INSTALLED FOR ANY RAIL LENGTH OF GREATER THAN 40'. %C ART ROOFING CONTRACTOR- D DISTANCE BETWEEN ARRAY EDGE AND TRANSITION FLASHING(COMPOSITION TO TILE)WILL BE A MINIMUM OF 3% 2)26 GAUGE INTERLOCKING FLASHING'SIDEWALL'TO BE INSTALLED ALONG THE LENGTH OF THE PV ARRAY AT ROOFING MATERIAL TRANSITION. IT SHALL BE APROVED PRIOR TO PV SYSTEM INSTALLATION. 3)PEEL-N-STICK BASE TO BE INSTALLED ONE FOOT(0 OR MORE BEYOND THE EDGE OF THE COMPOSITION SHINGLE,DOWN TO THE ROOF EAVE.PEEL-N-STICK BASE TO BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS. 4)AREAS UNDER EACH PV ARRAY SHALL BE ROOFED WITH COMPOSITION SHINGLE. COMPOSITION SHINGLE SHALL RUN FROM ABOVE THE PV ARRAY TO THE ROOF EAVE. ' 5)TILE INSTALLED BELOW THE ARRAY TO BE INSTALLED ABOVE THE COMPOSITION ROOF PER ROOFER SPECIFICATIONS. 6)BIRDSTOP WILL BE INSTALLED AT THE UPPERMOST TRANSITION FROM TILE TO COMPOSITION SHINGLE.BIRDSTOP TO BE SPECIFIED BY ROOFER PRIOR TO INSTALLATION. tobeaI ,t t e federa ive I plans r ELECTRICAL NOTES: GENFRAI - U ALL PV EUUIPPIEN1 WILL BE TESTED A14D LISTED FOR ITS USE BY A NATIONALLY RECOGNILLD TESTING LABORATORY(NRIL. 2)THE GROUNDING OF THE PHOTOVOLTAIC SYSTEM SHALL COMPLY WITH THE APPLICABLE VERSION OF THE NEC/CEC. 3)ALL GROUNDING ELECTRODE CONDUCTORS WILL BE INSTALLED IN A CONTINUOUS LENGTH EXCEPT WHERE SPLICED BY AN IRREVERSIBLE CONNECTOR OR EXOTHERMIC WELD. 4)NON-CURRENT CARRYING METAL PARTS SHALL BE CHECKED FOR PROPER GROUNDING.NOTING THAT TERMINAL LUGS BOLTED ON AN ENCLOSURE'S FINISHED SURFACE MAY BE ELECTRICALLY INSULATED BECAUSE OF PAINT/FINISH. PAINT/FINISH AT POINT OF CONTACT SHALL BE PROPERLY REMOVED. 5)ROOF PENETRATIONS WILL BE COMPLETED AND SEALED PER APPLICABLE CODE. 6)ALL CONDUCTORS WILL HAVE A 90-C RATING TO ENSURE CODE COMPLIANCE. SOLAR CONTRACTOR- 7)MODULE CERTIFICATIONS WILL INCLUDE LL1703,1EC616464 IEC61730. 8)CONDUIT AND CONDUCTOR SPECIFICATIONS.ARE BASED ON MINIMUM CODE REQUIREMENTS. 9)RACEWAY POINT OF PENETRATION FROM EXTERIOR TO INTERIOR WILL BE SEALED TO PREVENT INGRESS OF WATER AND INSECTS. 10)DC WIRING IS LIMITED TO PV ARRAY FOOTPRINT W/ENPHASE MICRO-INVERTER SYSTEM. ID MODULE AND ENPHASE WIRING SMALL BE LOCATED AND SECURED UNDER THE ARRAY USING SUITABLE WIRING CLIPS.WIRING SHALL NOT MAKE CONTACT WITH THE ROOF SURFACE AND SHALL BE MANAGED IN A WORKMAN-LIKE MANNER. 12)EQUIPMENT GROUNDING CONDUCTORS WILL BE SIZED IN ACCORDANCE WITH NEC TABLE 250.122. 13)CONDUCTOR TERMINATIONS WILL BE TORQUED PER DEVICE LISTING,OR MANUFACTURER'S RECOMMENDATIONS. 14)A PV AGGREGATION PANEL(SUB PANEL)WILL NOT BE INCLUDED FOR SYSTEMS WITH ONE BRANCH CIRCUIT. 15)A DEDICATED 120V BRANCH CIRCUIT IS REQUIRED IN MASTER CLOSET(OR EQUIVALENT)FOR ENPHASE ENVOY MONITOR. SIGNAGE- 16)PV SYSTEMS SHALL BE CLEARLY MARKED IN ACCORDANCE WITH NEC ARTICLE 690 AND OTHER APPLICABLE STATE AND LOCAL CODES. 17)ALL SAFETY MARKING/PLACARDS SHALL BE PERMANENTLY ATTACHED BY ADHESIVE OR OTHER MECHANICAL MEANS. 18)MARKING/PLACARDS WILL BE METAL OR PLASTIC WITH ENGRAVED OR MACHINE PRINTED LETTERING.BACKGROUND WILL BE RED WITH WHITE CAPITAL LETTERING OF MINIMUM HEIGHT". 19)ALL WIRING/RACEWAYS/JUNCTION BOXES WILL BE MARKED-PHOTOVOLTAIC POWER SOURCE:OR EQUIVALENT;WIRING/RACEWAYS SHALL BE MARKED EVERY 10'. BUILDER ELECTRICAL AND SOLAR CONTRACTORS- 20)INSTALLATION SHALL BE COMPLETED IN A NEAT AND WORKMAN-LIKE MANNER. 21)SPACE REQUIREMENTS FOR ALL ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110.26. LENNPR: ORIGINAL BY: DESIREE WILLIAMS DATE:15.09.26 MENIFEE HILLS REVIEWED BY: TOM FIDDES DATE:I5.09.25 9B0 MONTECITO DRIVE,#302 CORONA,CA 92879 REV.# BY DATE I DESCRIPTION d namastl3 roue DWG TITLE: PAGE#: SCALE: SITE LOCATION: 4571 Broadway Street INDIVIDUAL 29079 GUAVA STREET Boeltler,C080304 PLOT PLAN 3 NTS MENIFEE.CA 303447.03CO NOTES CAUTION: POWER TO THIS BUILDING IS SUPPLIED BY THE UTILITY AND A SOLAR PV SYSTEM. DISCONNECTS ARE LOCATED AS SHOWN. IENT DA rE for,or a sOUDEcx 1NRE muulnDR eD% ile or City (UI°ER N&GY) he kept on the .V 1[g5[IXiXEEi E%LERION 4M<4E 11I611V f1ElER B MEIN SERVICE PM'EL (VERIFIED RV RIpILFA) SERVICE BY QUALIFIED PERSONNEL ONLY CONTACT: SUNSTREET ENERGY GROUP 1-877-SLR-POWR PV POWER SOURCE - AC SPECS AC OPERATING VOLTAGE: 240 V AC OPERATING CURRENT: 12.6 A NOTE: SEE MASTER SET FOR ADDITIONAL PLACARD INFORMATION ORIGINAL BY: DESIREE WILLIAMS DATE:15.09.25 MENIFEE HILLS LENNAR: 980 MONTECITO DRIVE.#302 REVIEWED BY:TOM FIDDES I DATE:15.09.25 CORONA.CA 92879 REV.# BY DATE DESCRIPTION Vnamasl36 ROIAe DWG TITLE: P71SCALE- SITE LOCATION: 4571 BmaEway Street INDIVIDUAL 29079 GUAVA STREET BotAdw.CO 80304 PLOT PLAN MENIFEE,CA 303.447.0300 PLACARDS