PMT15-03413 City of Menifee Permit No.: PMT15-03413
29714 HAUN RD.
4ACCELA7 MENIFEE, CA 92586 Type: Residential Electrical
MENIFEE Date Issued: 1110 612 01 5
PERMIT
Site Address: 29067 GUAVA ST, MENIFEE, CA 92584 Parcel Number: 333-632-003
Construction Cost: $14,593.40
Existing Use: Proposed Use:
Description of SOLAR TR-31582-1 MENIFEE HILLS
Work: 3.71 KW 14 MODULES
LOT 42
Owner Contractor
LENNAR HOMES OF CA, INC LENNAR HOMES OF CALIFORNIA INC
980 MONTECITO DR#302 25 ENTERPRISE
CORONA, CA 92879 ALISO VIEJO, CA 92656
Applicant Phone:9493498269
JEREMIAH ACAYTURRI License Number.728102
LENNAR HOMES OF CALIFORNIA INC
25 ENTERPRISE
ALISO VIEJO,CA 92656
Fee Description 6Qyt Amount 1E1
Solar, Residential or Small Commercial 1 252.00
Building Permit Issuance 1 27.00
GREEN FEE 1 1.00
SMIP RESIDENTIAL 1 2.00
General Plan Maintenance Fee-Electrical 1 12.60
$294.60
The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and
specifications or from preventing builiding operations being carried on thereunder when in violation of the Building Code or of any other
ordinance of City of Menifee.Except as otherwise stated,a permit for construction under which no work is commenced within six
months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be
forfeited.
AA_Bldg_PerniLTemplate.rpt Page 1 of 1
CUILDING & SAFETY PERMIT/PLAN CHECK A. • •
41�
Y•,r'�JC
'Menifee
DATE 10/28/2015 PERMIT/PLAN CHECK NUMBER
TYPE: ❑COMMERCIAL ❑✓ RESIDENTIAL ❑MULTI-FAMILY ❑MOBILE HOME ❑POOL/SPA ❑SIGN
SUBTYPE: ❑✓ ADDITION ❑ALTERATION [-]DEMOLITION [-]ELECTRICAL [-]MECHANICAL
❑NEW []PLUMBING ❑RE-ROOF-NUMBER OF SQUARES
DESCRIPTION OF WORK SOLAR PERMIT-Plan 3105 3.71 kW/14 PCS
Master Solar Plan#PMT14-00706
PROJECT ADDRESS 29067 Guava St, Menifee,CA 92584
ASSESSOR'S PARCEL NUMBER 333-632-003 LOT 42 TRACT 31582-1
PROPERTY OWNER'S NAME Lennar Homes of California, Inc.
ADDRESS 980 Montecito Dr.,Suite 302
PHONE (951)817-3680 EMAIL jeremiah.acayturH@lennar.com
APPLICANT NAME Lennar Homes of California, Inc.
ADDRESS 980 Montecito Dr.,Suite 302,Corona,CA 92879
PHONE (951)817-3680 EMAIL Jeremiah.acayturri@lennar.com
CONTRACTOR'S NAME Lennar Homes of California, Inc. OWNER BUILDER? ❑✓ YES❑NO
BUSINESS NAME Lennar Homes of California, Inc.
ADDRESS 980 Montecito Dr.,Suite 302, Corona,CA 92879
PHONE (951)817-3680 EMAIL jeremiah.acayturri@lennar.com
CONTRACTOR'S STATE LIC NUMBER 728102 LICENSE CLASSIFICATION A&B
VALUATION $ $14,593.40 L SQ FT
APPLICANT'S SIGNATURE DATE
CITI(SrAFF USE ONLY
DEPARTMENT DISTRIBUTION CITY OF MENIFEE BUSINESS LICENSE NUMBER
BUILDING PLANNING ENGINEERING FIRE GREEN SMIP
INVOICE , bO PAID AMOUNT �-
AMOUNT CASH O CHECK# O CREDITCARD VISA/MC
PLAN CHECK FEES PAID AMOUNT 0CASH 0CHECK# OCREDITCARD VISA/MC
OWNER BUILDER VERIFIED OYES 0 No DL NUMBER NOTARIZED LETTER 0 YES O NO
City of Menifee Building&Safety Department 29714 Haun Rd. Menifee, CA 92586 951-672-6777
www.cityofinenifee.us Inspection Request Line 951-246-6213
SYSTEM INFORMATION BUYER ACKNOWLEDGES THAT THE SOLAR MODULES TO BE INSTALLED
ITEM 1 DTY MFR. 1 MODEL ON THE ROOF OF THE HOME WILL BE SUBSTANTIALLY IN THE
SYSTEM SIZE 3.71 KW LOCATIONS INDICATED BY THE ILLUSTRATION.
MODULE 1 14 PLS. HYUNDAI I HIS-SZ65RG(265W) BUYER:
INVERTER 1 14 PCS.1 ENPHASE I MZ15-60-2LL-S22-IG _ y O
ROOF TYPE I TILE W1 COMPOSITE SHINGLE UNDER ARRAY DATE: i
SUB-ARRAY INFORMATION
ARRAY#1 ARRAY#2 1 ARRAY#3 t% ILDI
M00 OTY 14 NA NA BUYER:
TILT 23° 1 NA' I NA° � N A
City
AZIMUTH 181° NA' NA' of Menitee DATE: P Building Dept
Nov 0 4 lub RE ICU6
Recely 4 *Ipprc ialoft
opprovj I of,ar
"gulati nsan(
22'-9'ARRAY jobsite ntil co,
23'-7'FLASHING 12'- '
}
SOLADECK WIRE
TRANSITION BOX +
(UNDER ARRAY)
Y
� L
PV AC DISCONNECT r- -- - L J
EXTERIOR-GARAGE ' ,� _w
UTILITY METER 8 jil
MAIN SERVICE PANEL(VERIFIED BY BUILDER) L_
vim' a
•
NOTE:DIMENSIONS ARE SHOWN IN PLANE OF ROOF
N
PLAN 3105 ELEVATION B
ORIENTATION 3 L #42
ORIGINAL BY: DESIREE WILLIAMS DATE:15.09.24
M EN I FEE HILLS LENNAR:
980 MONTECITO DRIVE.#302 REVIEWED BY:TOM FIDDES DATE:15.09.24
CORONA.CA 92879 REV.# BY DATE DESCRIPTION
�PnamasrdL
IOLA!
DWG TITLE: PAGE#: SCALE: SITE LOCATION: 4571 Sma(1Way Street
INDIVIDUAL 29067 GUAVA STREET Bouleer,CO MG4
PLOT PLAN 1 I/16'=1'-0' MENIFEE,CA 000A47.0000
SYSTEM LAYOUT
MODULE SPECS AND CALCULATIONS INVERTER SPECS AND CALCULATIONS
ITEM NOTE 7 CALC UNIT DETAIL ITEM NOTE/CALC UNIT DETAIL
LOCATION MENIFEE.CA INV. MAKE INVERTER SPEC ENPHASE
TEMP,AMBIENT HIGH(TMAX) ASHRAE 2% °C 37 INV. MODEL INVERTER SPEC M215-6D-2LL-S22-IG
TEMP,AMBIENT LOW(THIN) ASHRAE EXTR.MIN °C -2 INV. MAX POWER,(WA[MAX) INVERTER SPEC WATTS(AU 225 E
TEMP,MODULE TEST(TTEST) MODULE SPEC °C 25 INV. INPUT V.(VDc MAX) INVERTER SPEC VOLTS(oa) 48 7
TEMP.DELTA LOW(TOELTA) TMIN-TEEST °C -27 INV.OUTPUT V.(VAC NOM) INVERTER SPEC VOLTS(At) 240
MOD. MANUFACTURER MODULE SPEC HYUNDAI INV. OUTPUT FREGUENCY INVERTER SPEC HERTZ 60 AFE
MOD.PART NUMBER MODULE SPEC HIS-S265RG INV. OUTPUT CURRENT,At INVERTER SPEC AMPS(At) 0.9
MOD, POWER STC(P) MODULE SPEC WATTS(Dc) 265 INV.PHASE GUANTITY INVERTER SPEC PHASE I
MOD, POWER PTC MODULE SPEC WATTS(oc) 238 COMPLIANCE INVERTER SPEC UL174I/IEE
MOD. OPERATING VOLTAGE(VMP) MODULE SPEC VOLTS(130 31.30 INV. GROUNDING INVERTER SPEC ISOLATED
MOD. OPEN CCT. VOLTAGE(VM) MODULE SPEC VOLTS(DC) 38.10 INV. QTY.MAX/BRANCH CCT. INV.OTYBc OTY 14
MOD. COEFF.VOLT/TEMP(COEF) MODULE SPEC V/°C -0.114 BRANCH CCT.OUTPUT.IMAXBc (IAC•INVATYBC7 AMPS(AC) 12.60
MOD. MAX VOLTAGE(VMAxMOD) (VOD+(TDYDEF)) VOLTS(Dc) 41.18 INV,QUANTITY,TOTAL I INV.QTYT I OTY 1 14
MOD.OPERATING CURRENT(IMP) MODULE SPEC AMPS(DU B.50 TOTAL SYSTEM OUTPUT,IMAXTs I(IAC-INV.QTYT) AMPS(Ac) 12.60
MOD.SHORT CCT.CURRENT(ISO) MODULE SPEC AMPS(DO 9.00
MOD.MAXIMUM CURRENT(IMAX) (Isc• 1.25) AMPS(Dc) 11.25
MIN.AMPACITY REO'D.PER NEC (IMAX° 1.25) AMPS(DU 14.06
SERIES FUSE RATING,MAX MODULE SPEC AMPS(CC) IS
ELECTRICAL EQUIPMENT SCHEDULE 'plans shall not be
KEY OTY MANUFACTURER MODEL NOTES TRADE IDIatIOn of af y prom
1 14 HYUNDAI HIS-S265RG(265W) PV MODULE SOLAR 'dinances. TI is set(
2 14 ENPHASE M215-60-2LL-S22-I13 PVINVERTER SOLAR
3 I RSTC/SOLADECK 0766-3R5 PV ROOF JUNCTION BOX.NEMA 3R SOLAR 'etion.
4 1 CUTLER-HAMMER DG221URB PV AC DISCONNECT,NEMA 3R.24OV.30A SOLAR
5 I ENPHASE ENVOY PV DATA MONITOR,120V SOLAR
6 1 TBD TBD 120V DEDICATED RECEPTACLE FOR ENVOY PV DATA MONITOR SOLAR
7 1 TBD TBD CATS PORT FOR SOLAR PV INTERNET CONNECTION TO HOME NETWORK BOX SOLAR
8 NOTE CUTLER-HAMMER TBD PV BRANCH CIRCUIT BREAKERS;I x 15A-IP(ENVOY) SOLAR
9 NOTE CUT[FR-I IAMMFR TOO PV RRFAKER,I X 20A-2P.I.00ATF AT OPPOCITF FND OF BUS FROM MAIN BREAKER SOLAR
10 1 Teo TBD SERVICE PANEL,MIN. 125A BUS BLDR.ELEC.
11 1 TBD TBD UTILITY METER,IPH,120/240V,200A BLDR.ELEC.
12 1 1 1 TBD I TBD GROUNDING ELECTRODE LIFER I BLDR,ELEC.
CONDUCTOR SIZING CALCULATIONS INTERCONNECTION CALCULATIONS
1)CONDITION OF USE(COU): (AMPACITY•TEMP.DERATE•FILL DERATE) vs.REO'D(IMAX) ITEM UNIT PANEL
2)TERMINALS(TERM): AMPACITY AT TERMINALS. vs. REO'D,(IMAX° 1.25) PANEL MFR. CUTLER-HAMMER
KEY SIZE CU/AL INSULATION CALL. AMPACITY W/O TEMP. FILL RESULT REO'D OCD BUS RATING AMPS 200
TYPE DERATES DERATE DERATE (A) (A) USED(A) MAIN DISCONNECT AMPS 200
A #12 LU THWN-2 COU 30 0.76 1.0 22.130 12.60 ALLOWED PV PER NEC AMPS 1 40
TERM 25 25 15.75 20 PV oCPD DEVICE USED AMPS I20
B #10 LU NM-B COU 40 0.91 L0 36.40 12.60
TERM 35 35 15.75 20
C #10 CU NM-B COU 40 0.91 1.0 36.40 12.60
TERM 35 35 15.75 1 20
CONDUCTOR SCHEDULE
KEY CONDUCTORS 1 CU/AL 1 TYPE 1 LOCATION TRADE
A 1-#12 ENGAGE CABLE.1-#6G.FREE AIR CU TC-ER ARRAY SOUR
B 3-#10,1-910 EGC I CU I NM-B(ROMEX) I INTERIOR I SOLAR
L 1 3-910.1-910 EGC I CU I NM-B(ROMEX) I INTERIOR I SOLAR
D I CAT5E.ETHERNET CABLE I CU I CATSE I INTERIOR I SOLAR
"NOTE15
II
10
0 O
O B
isulF
0 0 c
L—IN
c a —_— s�
I r
ROOF E%TERIOq-LAPAGE L
ELECTRICAL DIAGRAM 3.71 XW
LOT#42
ORIGINAL BY: DESIREE WILLIAMS I DATE-
MENIFEE 15.09.24
MENIFEE HILLS REVIEWED BY:TOM FIDDES I DATE:15.09.24
980 MONTECITO DRIVE,#302
CORONA.CA 92879 REV.# BY DATE DESCRIPTION
namaste
WLAY
DWG TITLE: PAGE#: SCALE: SITE LOCATION: 4571 Broadway Street
INDIVIDUAL 29067 GUAVA STREET Boulder,CO 803N
PLOT PLAN 2 NITS MENIFEE,CA 303.447.0300
ELECTRICAL
STRUCTURAL NOTES:
SOLAR CONTRACTOR-
D ALL PV ROOF ATTACHMENTS WILL BE SPACED ALONG MODULE RACKING RAILS AT NOT GREATER THAN 48'O.C.
2)ALL PV ROOF ATTACHMENTS WILL BE STAGGERED BY ROW AMONGST THE ROOF FRAMING MEMBERS,TO MAXIMUM EXTENT POSSIBLE.
3)ROOF PENETRATIONS ASSOCIATED WITH SOLAR RACKING WILL BE SEALED WITH AN APPROVED SEALANT.
4)SOLADECK WIRE TRANSITION BOX WILL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS. IT WILL BE FLASHED AND SEALED.
5)PV ARRAY WILL BE A MINIMUM OF 3'ABOVE THE COMPOSITE SHINGLE ROOF SURFACE.
6)THE UNIRAC SOLARMOUNT RACKING SYSTEM AND SOLAR PV ARRAY WILL BE INSTALLED ACCORDING TO THE UNIRAC SOLARMOUNT CODE-COMPLIANT INSTALLATIOy EP RTM MANUAL,VERSION 227.3,PUB 140113-ICC.JANUARY 2014.
7)UNIRAC TOP CLAMPS REQUIRE A ONE INCH 01 SPACE BETWEEN PV MODULES.SOLARMOUNT RAILS MUST EXTEND A MINIMUM OF TWO INCHES(29 BEYOND THE EDGE
OF THE PV ARRAY/SUB-ARRAY.
8)UNIRAC SOLARMOUNT REQUIRES THAT A THERMAL EXPANSION GAP BE INSTALLED FOR ANY RAIL LENGTH OF GREATER THAN 40'.
ROOFING CONTRACTOR-
U DISTANCE BETWEEN ARRAY EDGE AND TRANSITION FLASHING(COMPOSITION TO TILE)WILL BE A MINIMUM OF 3'.
2)26 GAUGE INTERLOCKING FLASHING'SIDEWALL'TO BE INSTALLED ALONG THE LENGTH OF THE PV ARRAY AT ROOFING MATERIAL TRANSITION.IT SHALL BE
APROVED PRIOR TO PV SYSTEM INSTALLATION.
3)PEEL-N-STICK BASE TO BE INSTALLED ONE FOOT(19 OR MORE BEYOND THE EDGE OF THE COMPOSITION.SHINGLE,DOWN TO THE ROOF EAVE.PEEL-N-STICK BASE
BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS.
4)AREAS UNDER EACH PV ARRAY SHALL BE ROOFED WITH COMPOSITION SHINGLE.COMPOSITION SHINGLE SHALL RUN FROM ABOVE THE PV ARRAY TO THE ROOF EA
5)TILE INSTALLED BELOW THE ARRAY TO BE INSTALLED ABOVE THE COMPOSITION ROOF PER ROOFER SPECIFICATIONS.
6)BIRDSTOP WILL BE INSTALLED AT THE UPPERMOST TRANSITION FROM TILE TO COMPOSITION SHINGLE. BIROSTOP TO BE SPECIFIED BY ROOFER PRIOR TO
INSTALLATION. ,trued to be a per
Is of the decal,s
)proved lansmu
ELECTRICAL NOTES:
GENERA(. -
U ALL PV EOUIPMENI WILL BE TESIED AND LISI ED FOR ITS USE BY A NAI IUNALLY RECOGNIZED TESTING LABORAI OHY(NRTL).
2)THE GROUNDING OF THE PHOTOVOLTAIC SYSTEM SHALL COMPLY WITH THE APPLICABLE VERSION OF THE NEC/CEC.
3)ALL GROUNDING ELECTRODE CONDUCTORS WILL BE INSTALLED IN A CONTINUOUS LENGTH EXCEPT WHERE SPLICED BY AN IRREVERSIBLE CONNECTOR OR EXOTHERMIC
WELD.
4)NON-CURRENT CARRYING METAL PARTS SHALL BE CHECKED FOR PROPER GROUNDING.NOTING THAT TERMINAL LUGS BOLTED ON AN ENCLOSURE'S FINISHED SURFACE
MAY BE ELECTRICALLY INSULATED BECAUSE OF PAINT/FINISH. PAINT/FINISH AT POINT OF CONTACT SHALL BE PROPERLY REMOVED.
5)ROOF PENETRATIONS WILL BE COMPLETED AND SEALED PER APPLICABLE CODE.
6)ALL CONDUCTORS WILL HAVE A 90-C RATING TO ENSURE CODE COMPLIANCE.
SOLAR CONTRACTOR-
7)MODULE CERTIFICATIONS WILL INCLUDE UL1703.IEC61646,IEC61730.
8)CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS.
9)RACEWAY POINT OF PENETRATION FROM EXTERIOR TO INTERIOR WILL BE SEALED TO PREVENT INGRESS OF WATER AND INSECTS.
10)DC WIRING IS LIMITED TO PV ARRAY FOOTPRINT W/ENPHASE MICRO-INVERTER SYSTEM.
11)MODULE AND ENPHASE WIRING SHALL BE LOCATED AND SECURED UNDER THE ARRAY USING SUITABLE WIRING CLIPS. WIRING SHALL NOT MAKE CONTACT WITH THE
ROOF SURFACE AND SHALL BE MANAGED IN A WORKMAN-LIKE MANNER.
12)EQUIPMENT GROUNDING CONDUCTORS WILL BE SIZED IN ACCORDANCE WITH NEC TABLE 250.122.
13)CONDUCTOR TERMINATIONS WILL BE TORQUED PER DEVICE LISTING,OR MANUFACTURER'S RECOMMENDATIONS.
14)A PV AGGREGATION PANEL(SUB PANEL)WILL NOT BE INCLUDED FOR SYSTEMS WITH ONE BRANCH CIRCUIT.
15)A DEDICATED 120V BRANCH CIRCUIT IS REQUIRED IN MASTER CLOSET(OR EQUIVALENT)FOR ENPHASE ENVOY MONITOR.
SIGNAGE-
16)PV SYSTEMS SHALL BE CLEARLY MARKED IN ACCORDANCE WITH NEC ARTICLE 690 AND OTHER APPLICABLE STATE AND LOCAL CODES.
17)ALL SAFETY MARKING/PLACARDS SHALL BE PERMANENTLY ATTACHED BY ADHESIVE OR OTHER MECHANICAL MEANS.
18)MARKING/PLACARDS WILL BE METAL OR PLASTIC WITH ENGRAVED OR MACHINE PRINTED LETTERING.BACKGROUND WILL BE RED WITH WHITE CAPITAL LETTERING OF
MINIMUM HEIGHT t.
19)ALL WIRING/RACEWAYS/JUNCTION BOXES WILL BE MARKED*PHOTOVOLTAIC POWER SOURCE;OR EQUIVALENT;WIRING/RACEWAYS SHALL BE MARKED EVERY 10'.
BUILDER ELECTRICAL AND SOLAR CONTRACTORS-
20)INSTALLATION SHALL BE COMPLETED IN A NEAT AND WORKMAN-LIKE MANNER.
21)SPACE REQUIREMENTS FOR ALL ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110.26.
ORIGINAL BY: DESIREE WILLIAMS DATE:15.9 .
LENNAR: 24
MENIFEE HILLS REVIEWED BY; TOM FIDOES I DATE:1&09.24
980 MONTECITO DRIVE,#302
CORONA,CA 92879 REV.# BY DATE DESCRIPTION
11�2amasrii
30LAL
DWG TITLE: PAGE.#: SCALE: SITE LOCATION: 45718roa0way SVeal
INDIVIDUAL 29067 GUAVA STREET BoLAdw.CO 803M
PLOT PLAN 3 NTS MENIFEE,CA 303.447.0300
NOTES
CAUTION:
POWER TO THIS BUILDING IS SUPPLIED BY THE
UTILITY AND A SOLAR PV SYSTEM. DISCONNECTS VT
ARE LOCATED AS SHOWN.
II IL f116
DA FE-
or,or an
or city
kept on he
mL I w
ipYJ9TR' RDX
pNPEp amer)
PV 4c D="ECT
F%lERltl1-4Lpe4E
..or EL
IFIER e
ryepiFlEU BY RIM1OERI
(1 1
U
SERVICE BY QUALIFIED PERSONNEL ONLY
CONTACT: SUNSTREET ENERGY GROUP
I-877-SLR-POWR
PV POWER SOURCE - AC SPECS
AC OPERATING VOLTAGE: 240 V
AC OPERATING CURRENT: 12.6 A
NOTE: SEE MASTER SET FOR ADDITIONAL PLACARD INFORMATION
ORIGINAL BY: DESIREE WILLIAMS DATE:15.09.24
LENNAR:
MENIFEE HILLS 980 MONTECITO DRIVE,#302 REVIEWED BY:TOM FIDOES DATE:15.09,24
CORONA.CA 92879 REV.# BY DATE DESCRIPTION
Vnannastlb
sous
DWG TITLE: PAGE#: SCALE: SITE LOCATION: 4571 Broadway Street
INDIVIDUAL 29067 GUAVA STREET Boulder,CO ffl 0
PLOT PLAN L NTS MENIFEE.CA 303.447.0300
PLACARDS