Loading...
PMT15-03413 City of Menifee Permit No.: PMT15-03413 29714 HAUN RD. 4ACCELA7 MENIFEE, CA 92586 Type: Residential Electrical MENIFEE Date Issued: 1110 612 01 5 PERMIT Site Address: 29067 GUAVA ST, MENIFEE, CA 92584 Parcel Number: 333-632-003 Construction Cost: $14,593.40 Existing Use: Proposed Use: Description of SOLAR TR-31582-1 MENIFEE HILLS Work: 3.71 KW 14 MODULES LOT 42 Owner Contractor LENNAR HOMES OF CA, INC LENNAR HOMES OF CALIFORNIA INC 980 MONTECITO DR#302 25 ENTERPRISE CORONA, CA 92879 ALISO VIEJO, CA 92656 Applicant Phone:9493498269 JEREMIAH ACAYTURRI License Number.728102 LENNAR HOMES OF CALIFORNIA INC 25 ENTERPRISE ALISO VIEJO,CA 92656 Fee Description 6Qyt Amount 1E1 Solar, Residential or Small Commercial 1 252.00 Building Permit Issuance 1 27.00 GREEN FEE 1 1.00 SMIP RESIDENTIAL 1 2.00 General Plan Maintenance Fee-Electrical 1 12.60 $294.60 The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and specifications or from preventing builiding operations being carried on thereunder when in violation of the Building Code or of any other ordinance of City of Menifee.Except as otherwise stated,a permit for construction under which no work is commenced within six months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be forfeited. AA_Bldg_PerniLTemplate.rpt Page 1 of 1 CUILDING & SAFETY PERMIT/PLAN CHECK A. • • 41� Y•,r'�JC 'Menifee DATE 10/28/2015 PERMIT/PLAN CHECK NUMBER TYPE: ❑COMMERCIAL ❑✓ RESIDENTIAL ❑MULTI-FAMILY ❑MOBILE HOME ❑POOL/SPA ❑SIGN SUBTYPE: ❑✓ ADDITION ❑ALTERATION [-]DEMOLITION [-]ELECTRICAL [-]MECHANICAL ❑NEW []PLUMBING ❑RE-ROOF-NUMBER OF SQUARES DESCRIPTION OF WORK SOLAR PERMIT-Plan 3105 3.71 kW/14 PCS Master Solar Plan#PMT14-00706 PROJECT ADDRESS 29067 Guava St, Menifee,CA 92584 ASSESSOR'S PARCEL NUMBER 333-632-003 LOT 42 TRACT 31582-1 PROPERTY OWNER'S NAME Lennar Homes of California, Inc. ADDRESS 980 Montecito Dr.,Suite 302 PHONE (951)817-3680 EMAIL jeremiah.acayturH@lennar.com APPLICANT NAME Lennar Homes of California, Inc. ADDRESS 980 Montecito Dr.,Suite 302,Corona,CA 92879 PHONE (951)817-3680 EMAIL Jeremiah.acayturri@lennar.com CONTRACTOR'S NAME Lennar Homes of California, Inc. OWNER BUILDER? ❑✓ YES❑NO BUSINESS NAME Lennar Homes of California, Inc. ADDRESS 980 Montecito Dr.,Suite 302, Corona,CA 92879 PHONE (951)817-3680 EMAIL jeremiah.acayturri@lennar.com CONTRACTOR'S STATE LIC NUMBER 728102 LICENSE CLASSIFICATION A&B VALUATION $ $14,593.40 L SQ FT APPLICANT'S SIGNATURE DATE CITI(SrAFF USE ONLY DEPARTMENT DISTRIBUTION CITY OF MENIFEE BUSINESS LICENSE NUMBER BUILDING PLANNING ENGINEERING FIRE GREEN SMIP INVOICE , bO PAID AMOUNT �- AMOUNT CASH O CHECK# O CREDITCARD VISA/MC PLAN CHECK FEES PAID AMOUNT 0CASH 0CHECK# OCREDITCARD VISA/MC OWNER BUILDER VERIFIED OYES 0 No DL NUMBER NOTARIZED LETTER 0 YES O NO City of Menifee Building&Safety Department 29714 Haun Rd. Menifee, CA 92586 951-672-6777 www.cityofinenifee.us Inspection Request Line 951-246-6213 SYSTEM INFORMATION BUYER ACKNOWLEDGES THAT THE SOLAR MODULES TO BE INSTALLED ITEM 1 DTY MFR. 1 MODEL ON THE ROOF OF THE HOME WILL BE SUBSTANTIALLY IN THE SYSTEM SIZE 3.71 KW LOCATIONS INDICATED BY THE ILLUSTRATION. MODULE 1 14 PLS. HYUNDAI I HIS-SZ65RG(265W) BUYER: INVERTER 1 14 PCS.1 ENPHASE I MZ15-60-2LL-S22-IG _ y O ROOF TYPE I TILE W1 COMPOSITE SHINGLE UNDER ARRAY DATE: i SUB-ARRAY INFORMATION ARRAY#1 ARRAY#2 1 ARRAY#3 t% ILDI M00 OTY 14 NA NA BUYER: TILT 23° 1 NA' I NA° � N A City AZIMUTH 181° NA' NA' of Menitee DATE: P Building Dept Nov 0 4 lub RE ICU6 Recely 4 *Ipprc ialoft opprovj I of,ar "gulati nsan( 22'-9'ARRAY jobsite ntil co, 23'-7'FLASHING 12'- ' } SOLADECK WIRE TRANSITION BOX + (UNDER ARRAY) Y � L PV AC DISCONNECT r- -- - L J EXTERIOR-GARAGE ' ,� _w UTILITY METER 8 jil MAIN SERVICE PANEL(VERIFIED BY BUILDER) L_ vim' a • NOTE:DIMENSIONS ARE SHOWN IN PLANE OF ROOF N PLAN 3105 ELEVATION B ORIENTATION 3 L #42 ORIGINAL BY: DESIREE WILLIAMS DATE:15.09.24 M EN I FEE HILLS LENNAR: 980 MONTECITO DRIVE.#302 REVIEWED BY:TOM FIDDES DATE:15.09.24 CORONA.CA 92879 REV.# BY DATE DESCRIPTION �PnamasrdL IOLA! DWG TITLE: PAGE#: SCALE: SITE LOCATION: 4571 Sma(1Way Street INDIVIDUAL 29067 GUAVA STREET Bouleer,CO MG4 PLOT PLAN 1 I/16'=1'-0' MENIFEE,CA 000A47.0000 SYSTEM LAYOUT MODULE SPECS AND CALCULATIONS INVERTER SPECS AND CALCULATIONS ITEM NOTE 7 CALC UNIT DETAIL ITEM NOTE/CALC UNIT DETAIL LOCATION MENIFEE.CA INV. MAKE INVERTER SPEC ENPHASE TEMP,AMBIENT HIGH(TMAX) ASHRAE 2% °C 37 INV. MODEL INVERTER SPEC M215-6D-2LL-S22-IG TEMP,AMBIENT LOW(THIN) ASHRAE EXTR.MIN °C -2 INV. MAX POWER,(WA[MAX) INVERTER SPEC WATTS(AU 225 E TEMP,MODULE TEST(TTEST) MODULE SPEC °C 25 INV. INPUT V.(VDc MAX) INVERTER SPEC VOLTS(oa) 48 7 TEMP.DELTA LOW(TOELTA) TMIN-TEEST °C -27 INV.OUTPUT V.(VAC NOM) INVERTER SPEC VOLTS(At) 240 MOD. MANUFACTURER MODULE SPEC HYUNDAI INV. OUTPUT FREGUENCY INVERTER SPEC HERTZ 60 AFE MOD.PART NUMBER MODULE SPEC HIS-S265RG INV. OUTPUT CURRENT,At INVERTER SPEC AMPS(At) 0.9 MOD, POWER STC(P) MODULE SPEC WATTS(Dc) 265 INV.PHASE GUANTITY INVERTER SPEC PHASE I MOD, POWER PTC MODULE SPEC WATTS(oc) 238 COMPLIANCE INVERTER SPEC UL174I/IEE MOD. OPERATING VOLTAGE(VMP) MODULE SPEC VOLTS(130 31.30 INV. GROUNDING INVERTER SPEC ISOLATED MOD. OPEN CCT. VOLTAGE(VM) MODULE SPEC VOLTS(DC) 38.10 INV. QTY.MAX/BRANCH CCT. INV.OTYBc OTY 14 MOD. COEFF.VOLT/TEMP(COEF) MODULE SPEC V/°C -0.114 BRANCH CCT.OUTPUT.IMAXBc (IAC•INVATYBC7 AMPS(AC) 12.60 MOD. MAX VOLTAGE(VMAxMOD) (VOD+(TDYDEF)) VOLTS(Dc) 41.18 INV,QUANTITY,TOTAL I INV.QTYT I OTY 1 14 MOD.OPERATING CURRENT(IMP) MODULE SPEC AMPS(DU B.50 TOTAL SYSTEM OUTPUT,IMAXTs I(IAC-INV.QTYT) AMPS(Ac) 12.60 MOD.SHORT CCT.CURRENT(ISO) MODULE SPEC AMPS(DO 9.00 MOD.MAXIMUM CURRENT(IMAX) (Isc• 1.25) AMPS(Dc) 11.25 MIN.AMPACITY REO'D.PER NEC (IMAX° 1.25) AMPS(DU 14.06 SERIES FUSE RATING,MAX MODULE SPEC AMPS(CC) IS ELECTRICAL EQUIPMENT SCHEDULE 'plans shall not be KEY OTY MANUFACTURER MODEL NOTES TRADE IDIatIOn of af y prom 1 14 HYUNDAI HIS-S265RG(265W) PV MODULE SOLAR 'dinances. TI is set( 2 14 ENPHASE M215-60-2LL-S22-I13 PVINVERTER SOLAR 3 I RSTC/SOLADECK 0766-3R5 PV ROOF JUNCTION BOX.NEMA 3R SOLAR 'etion. 4 1 CUTLER-HAMMER DG221URB PV AC DISCONNECT,NEMA 3R.24OV.30A SOLAR 5 I ENPHASE ENVOY PV DATA MONITOR,120V SOLAR 6 1 TBD TBD 120V DEDICATED RECEPTACLE FOR ENVOY PV DATA MONITOR SOLAR 7 1 TBD TBD CATS PORT FOR SOLAR PV INTERNET CONNECTION TO HOME NETWORK BOX SOLAR 8 NOTE CUTLER-HAMMER TBD PV BRANCH CIRCUIT BREAKERS;I x 15A-IP(ENVOY) SOLAR 9 NOTE CUT[FR-I IAMMFR TOO PV RRFAKER,I X 20A-2P.I.00ATF AT OPPOCITF FND OF BUS FROM MAIN BREAKER SOLAR 10 1 Teo TBD SERVICE PANEL,MIN. 125A BUS BLDR.ELEC. 11 1 TBD TBD UTILITY METER,IPH,120/240V,200A BLDR.ELEC. 12 1 1 1 TBD I TBD GROUNDING ELECTRODE LIFER I BLDR,ELEC. CONDUCTOR SIZING CALCULATIONS INTERCONNECTION CALCULATIONS 1)CONDITION OF USE(COU): (AMPACITY•TEMP.DERATE•FILL DERATE) vs.REO'D(IMAX) ITEM UNIT PANEL 2)TERMINALS(TERM): AMPACITY AT TERMINALS. vs. REO'D,(IMAX° 1.25) PANEL MFR. CUTLER-HAMMER KEY SIZE CU/AL INSULATION CALL. AMPACITY W/O TEMP. FILL RESULT REO'D OCD BUS RATING AMPS 200 TYPE DERATES DERATE DERATE (A) (A) USED(A) MAIN DISCONNECT AMPS 200 A #12 LU THWN-2 COU 30 0.76 1.0 22.130 12.60 ALLOWED PV PER NEC AMPS 1 40 TERM 25 25 15.75 20 PV oCPD DEVICE USED AMPS I20 B #10 LU NM-B COU 40 0.91 L0 36.40 12.60 TERM 35 35 15.75 20 C #10 CU NM-B COU 40 0.91 1.0 36.40 12.60 TERM 35 35 15.75 1 20 CONDUCTOR SCHEDULE KEY CONDUCTORS 1 CU/AL 1 TYPE 1 LOCATION TRADE A 1-#12 ENGAGE CABLE.1-#6G.FREE AIR CU TC-ER ARRAY SOUR B 3-#10,1-910 EGC I CU I NM-B(ROMEX) I INTERIOR I SOLAR L 1 3-910.1-910 EGC I CU I NM-B(ROMEX) I INTERIOR I SOLAR D I CAT5E.ETHERNET CABLE I CU I CATSE I INTERIOR I SOLAR "NOTE15 II 10 0 O O B isulF 0 0 c L—IN c a —_— s� I r ROOF E%TERIOq-LAPAGE L ELECTRICAL DIAGRAM 3.71 XW LOT#42 ORIGINAL BY: DESIREE WILLIAMS I DATE- MENIFEE 15.09.24 MENIFEE HILLS REVIEWED BY:TOM FIDDES I DATE:15.09.24 980 MONTECITO DRIVE,#302 CORONA.CA 92879 REV.# BY DATE DESCRIPTION namaste WLAY DWG TITLE: PAGE#: SCALE: SITE LOCATION: 4571 Broadway Street INDIVIDUAL 29067 GUAVA STREET Boulder,CO 803N PLOT PLAN 2 NITS MENIFEE,CA 303.447.0300 ELECTRICAL STRUCTURAL NOTES: SOLAR CONTRACTOR- D ALL PV ROOF ATTACHMENTS WILL BE SPACED ALONG MODULE RACKING RAILS AT NOT GREATER THAN 48'O.C. 2)ALL PV ROOF ATTACHMENTS WILL BE STAGGERED BY ROW AMONGST THE ROOF FRAMING MEMBERS,TO MAXIMUM EXTENT POSSIBLE. 3)ROOF PENETRATIONS ASSOCIATED WITH SOLAR RACKING WILL BE SEALED WITH AN APPROVED SEALANT. 4)SOLADECK WIRE TRANSITION BOX WILL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS. IT WILL BE FLASHED AND SEALED. 5)PV ARRAY WILL BE A MINIMUM OF 3'ABOVE THE COMPOSITE SHINGLE ROOF SURFACE. 6)THE UNIRAC SOLARMOUNT RACKING SYSTEM AND SOLAR PV ARRAY WILL BE INSTALLED ACCORDING TO THE UNIRAC SOLARMOUNT CODE-COMPLIANT INSTALLATIOy EP RTM MANUAL,VERSION 227.3,PUB 140113-ICC.JANUARY 2014. 7)UNIRAC TOP CLAMPS REQUIRE A ONE INCH 01 SPACE BETWEEN PV MODULES.SOLARMOUNT RAILS MUST EXTEND A MINIMUM OF TWO INCHES(29 BEYOND THE EDGE OF THE PV ARRAY/SUB-ARRAY. 8)UNIRAC SOLARMOUNT REQUIRES THAT A THERMAL EXPANSION GAP BE INSTALLED FOR ANY RAIL LENGTH OF GREATER THAN 40'. ROOFING CONTRACTOR- U DISTANCE BETWEEN ARRAY EDGE AND TRANSITION FLASHING(COMPOSITION TO TILE)WILL BE A MINIMUM OF 3'. 2)26 GAUGE INTERLOCKING FLASHING'SIDEWALL'TO BE INSTALLED ALONG THE LENGTH OF THE PV ARRAY AT ROOFING MATERIAL TRANSITION.IT SHALL BE APROVED PRIOR TO PV SYSTEM INSTALLATION. 3)PEEL-N-STICK BASE TO BE INSTALLED ONE FOOT(19 OR MORE BEYOND THE EDGE OF THE COMPOSITION.SHINGLE,DOWN TO THE ROOF EAVE.PEEL-N-STICK BASE BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS. 4)AREAS UNDER EACH PV ARRAY SHALL BE ROOFED WITH COMPOSITION SHINGLE.COMPOSITION SHINGLE SHALL RUN FROM ABOVE THE PV ARRAY TO THE ROOF EA 5)TILE INSTALLED BELOW THE ARRAY TO BE INSTALLED ABOVE THE COMPOSITION ROOF PER ROOFER SPECIFICATIONS. 6)BIRDSTOP WILL BE INSTALLED AT THE UPPERMOST TRANSITION FROM TILE TO COMPOSITION SHINGLE. BIROSTOP TO BE SPECIFIED BY ROOFER PRIOR TO INSTALLATION. ,trued to be a per Is of the decal,s )proved lansmu ELECTRICAL NOTES: GENERA(. - U ALL PV EOUIPMENI WILL BE TESIED AND LISI ED FOR ITS USE BY A NAI IUNALLY RECOGNIZED TESTING LABORAI OHY(NRTL). 2)THE GROUNDING OF THE PHOTOVOLTAIC SYSTEM SHALL COMPLY WITH THE APPLICABLE VERSION OF THE NEC/CEC. 3)ALL GROUNDING ELECTRODE CONDUCTORS WILL BE INSTALLED IN A CONTINUOUS LENGTH EXCEPT WHERE SPLICED BY AN IRREVERSIBLE CONNECTOR OR EXOTHERMIC WELD. 4)NON-CURRENT CARRYING METAL PARTS SHALL BE CHECKED FOR PROPER GROUNDING.NOTING THAT TERMINAL LUGS BOLTED ON AN ENCLOSURE'S FINISHED SURFACE MAY BE ELECTRICALLY INSULATED BECAUSE OF PAINT/FINISH. PAINT/FINISH AT POINT OF CONTACT SHALL BE PROPERLY REMOVED. 5)ROOF PENETRATIONS WILL BE COMPLETED AND SEALED PER APPLICABLE CODE. 6)ALL CONDUCTORS WILL HAVE A 90-C RATING TO ENSURE CODE COMPLIANCE. SOLAR CONTRACTOR- 7)MODULE CERTIFICATIONS WILL INCLUDE UL1703.IEC61646,IEC61730. 8)CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS. 9)RACEWAY POINT OF PENETRATION FROM EXTERIOR TO INTERIOR WILL BE SEALED TO PREVENT INGRESS OF WATER AND INSECTS. 10)DC WIRING IS LIMITED TO PV ARRAY FOOTPRINT W/ENPHASE MICRO-INVERTER SYSTEM. 11)MODULE AND ENPHASE WIRING SHALL BE LOCATED AND SECURED UNDER THE ARRAY USING SUITABLE WIRING CLIPS. WIRING SHALL NOT MAKE CONTACT WITH THE ROOF SURFACE AND SHALL BE MANAGED IN A WORKMAN-LIKE MANNER. 12)EQUIPMENT GROUNDING CONDUCTORS WILL BE SIZED IN ACCORDANCE WITH NEC TABLE 250.122. 13)CONDUCTOR TERMINATIONS WILL BE TORQUED PER DEVICE LISTING,OR MANUFACTURER'S RECOMMENDATIONS. 14)A PV AGGREGATION PANEL(SUB PANEL)WILL NOT BE INCLUDED FOR SYSTEMS WITH ONE BRANCH CIRCUIT. 15)A DEDICATED 120V BRANCH CIRCUIT IS REQUIRED IN MASTER CLOSET(OR EQUIVALENT)FOR ENPHASE ENVOY MONITOR. SIGNAGE- 16)PV SYSTEMS SHALL BE CLEARLY MARKED IN ACCORDANCE WITH NEC ARTICLE 690 AND OTHER APPLICABLE STATE AND LOCAL CODES. 17)ALL SAFETY MARKING/PLACARDS SHALL BE PERMANENTLY ATTACHED BY ADHESIVE OR OTHER MECHANICAL MEANS. 18)MARKING/PLACARDS WILL BE METAL OR PLASTIC WITH ENGRAVED OR MACHINE PRINTED LETTERING.BACKGROUND WILL BE RED WITH WHITE CAPITAL LETTERING OF MINIMUM HEIGHT t. 19)ALL WIRING/RACEWAYS/JUNCTION BOXES WILL BE MARKED*PHOTOVOLTAIC POWER SOURCE;OR EQUIVALENT;WIRING/RACEWAYS SHALL BE MARKED EVERY 10'. BUILDER ELECTRICAL AND SOLAR CONTRACTORS- 20)INSTALLATION SHALL BE COMPLETED IN A NEAT AND WORKMAN-LIKE MANNER. 21)SPACE REQUIREMENTS FOR ALL ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110.26. ORIGINAL BY: DESIREE WILLIAMS DATE:15.9 . LENNAR: 24 MENIFEE HILLS REVIEWED BY; TOM FIDOES I DATE:1&09.24 980 MONTECITO DRIVE,#302 CORONA,CA 92879 REV.# BY DATE DESCRIPTION 11�2amasrii 30LAL DWG TITLE: PAGE.#: SCALE: SITE LOCATION: 45718roa0way SVeal INDIVIDUAL 29067 GUAVA STREET BoLAdw.CO 803M PLOT PLAN 3 NTS MENIFEE,CA 303.447.0300 NOTES CAUTION: POWER TO THIS BUILDING IS SUPPLIED BY THE UTILITY AND A SOLAR PV SYSTEM. DISCONNECTS VT ARE LOCATED AS SHOWN. II IL f116 DA FE- or,or an or city kept on he mL I w ipYJ9TR' RDX pNPEp amer) PV 4c D="ECT F%lERltl1-4Lpe4E ..or EL IFIER e ryepiFlEU BY RIM1OERI (1 1 U SERVICE BY QUALIFIED PERSONNEL ONLY CONTACT: SUNSTREET ENERGY GROUP I-877-SLR-POWR PV POWER SOURCE - AC SPECS AC OPERATING VOLTAGE: 240 V AC OPERATING CURRENT: 12.6 A NOTE: SEE MASTER SET FOR ADDITIONAL PLACARD INFORMATION ORIGINAL BY: DESIREE WILLIAMS DATE:15.09.24 LENNAR: MENIFEE HILLS 980 MONTECITO DRIVE,#302 REVIEWED BY:TOM FIDOES DATE:15.09,24 CORONA.CA 92879 REV.# BY DATE DESCRIPTION Vnannastlb sous DWG TITLE: PAGE#: SCALE: SITE LOCATION: 4571 Broadway Street INDIVIDUAL 29067 GUAVA STREET Boulder,CO ffl 0 PLOT PLAN L NTS MENIFEE.CA 303.447.0300 PLACARDS