Loading...
PMT15-03411 City of Menifee Permit No.: PMT15-03411 29714 HAUN RD. Type: Residential Electrical { �;,CCEL/-> MENIFEE,CA 92586 MENIFEE Date Issued: 11/0 612 0 1 6 PERMIT Site Address: 29043 GUAVA ST, MENIFEE, CA 92584 Parcel Number: 333-632-001 Construction Cost: $8,017.20 Existing Use: Proposed Use: Description of SOLAR TR-31582-1 MENIFEE HILLS Work: 3.18KW 12 MODULES LOT 40 Owner Contractor LENNAR HOMES OF CA, INC LENNAR HOMES OF CALIFORNIA INC 980 MONTECITO DR#302 25 ENTERPRISE CORONA, CA 92879 ALISO VIEJO, CA 92656 Applicant Phone: 9493498269 JEREMIAH ACAYTURRI License Number: 728102 LENNAR HOMES OF CALIFORNIA INC 25 ENTERPRISE ALISO VIEJO, CA 92656 Fee Description City. Amount f51 Solar, Residential or Small Commercial 1 252.00 Building Permit Issuance 1 27.00 GREEN FEE 1 1.00 SMIP RESIDENTIAL 1 2.00 General Plan Maintenance Fee-Electrical 1 12.60 $294.60 The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and specifications or from preventing builiding operations being carried on thereunder when in violation of the Building Code or of any other ordinance of City of Menifee.Except as otherwise stated,a permit for construction under which no work is commenced within six months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be forfeited. AA_Bldg_Permit_Template.rpt Page 1 of 1 BUILDINGAPPLICATION 4• �'Menifee DATE 10/28/2015 PERMIT/PLAN CHECK NUMBER TYPE: ❑COMMERCIAL ❑✓ RESIDENTIAL ❑MULTI-FAMILY ❑MOBILE HOME ❑POOL/SPA []SIGN SUBTYPE: ❑✓ ADDITION ❑ALTERATION []DEMOLITION ❑ELECTRICAL ❑MECHANICAL [—]NEW [—]PLUMBING [—IRE-ROOF-NUMBER OF SQUARES DESCRIPTION OF WORK SOLAR PERMIT-Plan 2686-3.18 kW/12 PCS Master Solar Plan#PMT14-00706 PROJECT ADDRESS 29043 Guava St, Menifee,CA 92584 ASSESSOR'S PARCEL NUMBER 333-632-001 LOT 40 TRACT 31.582-1 PROPERTY OWNER'S NAME Lennar Homes of California, Inc. ADDRESS 980 Montecito Dr.,Suite 302 PHONE (951)817-3680 EMAIL jeremiah.acayturri@lennar.com APPLICANT NAME Lennar Homes of California, Inc. ADDRESS 980 Montecito Dr.,Suite 302, Corona,CA 92879 PHONE (951)817-3680 EMAIL jeremiah.acayturri@lennar.com CONTRACTOR'S NAME Lennar Homes of California,Inc. OWNER BUILDER? ❑✓ YES❑NO BUSINESS NAME Lennar Homes of California, Inc. ADDRESS 980 Montecito Dr.,Suite 302, Corona,CA 92879 PHONE (951)817-3680 EMAIL jeremiah.acayturri@lennar.com CONTRACTOR'S STATE LIC NUMBER 728102 LICENSE CLASSIFICATION A&B VALUATION$ $8,017.20 L SO.FT APPLICANT'S SIGNATURE DATE DEPARTMENT DISTRIBUTION ^J 4� CITY OF MENIFEE BUSINESS UCENSE NUMBER BUILDING PLANNING ENGINEERING FIRE GREEN SMIP INVOICE GG�� r/�y1�/ PAID AMOUNT AMOUNT � / OCASH OCHECK# OCREDIT CARD VISA/MC PLAN CHECK FEES PAID AMOUNT OCASH OCHECK# 0CREDIT CARD VISA/MC OWNER BUILDER VERIFIED O YES O No DL NUMBER NOTARIZED LETTER O YES O NO City of Menifee Building&Safety Department 29714 Haun Rd. Menifee, CA 92586 951-672-6777 www.cityofinenifee.us Inspection Request Line 951-246-6213 SYSTEM INFORMATION BUYER ACKNOWLEDGES THAT THE SOLAR MODULES TO BE INSTALLED ITEM 1 OTY MFR. 1 MODEL ON THE ROOF OF THE HOME WILL BE SUBSTANTIALLY IN THE SYSTEM SIZE 3.18 KW LOCATIONS INDICATED BY THE ILLUSTRATION. MODULE 1 12 PCS, HYUNDAI I HIS-SZ65RG (265W) BUYER: INVERTER 1 12 PCS.1 ENPHASE I 4215-60-2LL-S22-IG I City of Menifes [ ROOF TYPE TILE W/COMPOSITE SHINGLE UNDER ARRAY Building Dep'i DATE: ) F M NIr SUB-ARRAY INFORMATION �}} ARRAY#1 ARRAY#2 ARRAY#3 L`Li I LDING NC MOD OTY 12 NA NA NOV 04 *_12;) BUYER: TILT 23° NA' NA° AZIMUTH 1 91° 1 NA' I NA' DATE. APPROM REVIEWED B� 10-10• 3 '�Dproval of these danssi approval of,any vio 3tion c -gulations and ord iances Iobsite until comple ion. I I I I I I I I ¢N I I ag I I P: N I I I I SADECK WIRE TRANSITION BOX (UNDER ARRAY) I I I I I s I I I I ✓, I I v PV AC DISCONNECT EXTERIOR-GARAGEsoft I UTILITY METER fl i MAIN SERVICE PANEL — (VERIFIED BY BUILDER) I L 400 NOTE:DIMENSIONS ARE SHOWN IN PLANE OF ROOF ` PLAN 2686 ELEVATION A ORIENTATION 4 L0 0 40 N Q ORIGINAL BY: DESIREE WILLIAMS I DATE:15.09.24 MENIFEE HILLS LENNAR: 980 MONTECITO DRIVE,#302 REVIEWED BY:TOM FIDDES I DATE:15.09.24 CORONA.CA 92879 REV.# BY DATE DESCRIPTION Vnamast;6 lGl/d DWG TITLE: PAGE#: SCALE: SITE LOCATION: 4671 Bros ay Sleet INDIVIDUAL 29043 GUAVA STREET BOWdw,CO 90304 PLOT PLAN 1 1/16•=1'-0• MENIFEE,CA 303.447.0300 SYSTEM LAYOUT MODULE SPECS AND CALCULATIONS INVERTER SPECS AND CALCULATIONS ITEM NOTE/CALC UNIT DETAIL ITEM NOTE/COLIC UNIT I DETAIL LOCATION MENIFEE,CA INV.MAKE INVERTER SPEC ENPHASE TEMP,AMBIENT HIGH(TMAx) ASHRAE 2% •C 37 INV. MODEL INVERTER SPEC 1`1215-60-2LL-S22-I15 TEMP,AMBIENT LOW(THIN) ASHRAE EXTR.MIN •C -2 INV.MAX POWER.(WAC MAX) INVERTER SPEC WATTS(AD) 225 TEMP,MODULE TEST(TTEST) MODULE SPEC •C 25 INV. INPUT V.(VDL MAX) INVERTER SPEC VOLTS(DO 48 TEMP,DELTA LOW(TEELTA) THIN-TTEST •C -27 INV.OUTPUT V.(VAc NON) INVERTER SPEC VOLTS(Ad 240 MOD.MANUFACTURER MODULE SPEC HYUNDAI INV.OUTPUT FREQUENCY INVERTER SPEC HERTZ 60 MOD.PART NUMBER MODULE SPEC HIS-S26SRG INV.OUTPUT CURRENT,IAC INVERTER SPEC AMPS(AC) 0.9 MOD.POWER STC(P) MODULE SPEC WATTS(oc) 265 INV.PHASE QUANTITY INVERTER SPEC PHASE I MOD.POWER PTC MODULE SPEC WATTS(DC) 238 COMPLIANCE INVERTER SPEC UL1741/IEEE1547 MOD.OPERATING VOLTAGE(VMP) MODULE SPEC VOLTS(DC) 31.30 INV. GROUNDING INVERTER SPEC ISOLATED MOD.OPEN CCT.VOLTAGE WOO MODULE SPEC VOLTS(Dc) 38.10 INV.OTY,MAX/BRANCH CCT. INVATYec OTY 12 �\ MOD.COEFF.VOLT/TEMP(COEF) MODULE SPEC V/•C -0,114 BRANCH CCT.OUTPUT.IMAXEC (IAC•INV.QTYaC) I AMPS(AU 10.80 MOD.MAX VOLTAGE(VMAIDIOD) (VOC♦(To•COEF)) VOLTS(oc) 41.18 INV.QUANTITY,TOTAL INVATYT 1 OTY' 12 MOD.OPERATING CURRENT(IMP) MODULE SPEC AMPS(13C) 8.50 TOTAL SYSTEM OUTPUT,IMAXJS 0AC•INV.OTYT) I AMPS(AC) 10.80 MOD.SHORT CCT.CURRENT(Isc) MODULE SPEC AMPS(oc) 9.00 MOD,MAXIMUM CURRENT(IMAX) (ISL• 1.25) AMPS(oc) 11.25 MIN.AMPACITY REG'D.PER NEC ([MAX•1.25) AMPS(oc) 14.06 SERIES FUSE RATING,MAX MODULE SPEC AMPS(DC) 15 ELECTRICAL EQUIPMENT SCHEDULE not bet nstru( KEY OTY MANUFACTURER MODEL I NOTES TRADE I provis ons of 1 12 HYUNDAI HIS-S265RG(265W) PV MODULE SOLAR 2 12 ENPHASE M215-60-2LL-S22-IG PV INVERTER SOLAR )is set of approl 3 1 RSTC/SOLADECK 0786-3R5 PV ROOF JUNCTION BOX,NEMA 3R SOLAR 4 1 CUTLER-HAMMER DG221URB PV AC DISCONNECT,NEMA 3R,240V,30A SOLAR 5 1 ENPHASE ENVOY PV DATA MONITOR.120V SOLAR 6 1 TBD TBD 120V DEDICATED RECEPTACLE FOR ENVOY PV DATA MONITOR SOLAR 7 1 TBD TBD CATS PORT FOR SOLAR PV INTERNET CONNECTION TO HOME NETWORK BOX SOLAR 8 NOTE CUTLER-HAMMER TBD PV BRANCH CIRCUIT BREAKERS: I x 15A-IP(ENVOY) SOLAR 9 NOTE CUTI.ER-HAMMER TRD PV BRFAKFR. I x 2DA-7P,I OCATF AT OPPOSITE FND OF RUS FROM MAIN P.RFAKFR SOIAR 10 I TBD TBO SERVICE PANEL.MIN. 125A BUS BLOB.ELEC. II 1 TBD TBD UTILITY METER.IPH, 120/24OV,200A BLDR.ELEC. 12 I TBD TBD GROUNDING ELECTRODE LIFER BLDR.ELEC. CONDUCTOR SIZING CALCULATIONS INTERCONNECTION CALCULATIONS 0 CONDITION OF USE(COU): (AMPACITY•TEMP.DERATE•FILL DEBATE) Vs.REQ'D(IMAx) ITEM UNIT PANEL 2)TERMINALS(TERM): AMPACITY AT TERMINALS. vs.REQ'D,(IMAx• 1.25) PANEL MFR. CUTLER-HAMMER KEY SIZE CU/AI. INSULATION CALC. AMPACITY W/0 TEMP. FILL RESULT REO'D OCD BUS RATING AMPS 200 TYPE DERATES DERATE DERATE (A) (A) USED(A) MAIN DISCONNECT AMPS 200 A #12 CU THWN-2 COU 30 W22.80 10.80 ALLOWED PV PER NEC AMPS 40 TERM 2525 13.50 20 PV OCPD DEVICE USED AMPS 20 B #10 CU NM-S COU 40 36.40TERM 3535 13.50 20 C #10 CU NM-B COU 40 36.40 10.80TERM 3535 13.50 1 20 CONDUCTOR SCHEDULE KEY CONDUCTORS CU/AL TYPE LOCATION TRADE A I-#12 ENGAGE CABLE.1-#6G,FREE AIR CU TC-ER ARRAY SOLAR 3_1N B 3-#10.I-#10 ESE CU NM-B(ROMEX) INTERIOR SOLARC 3-#10.[-#10 EGL CU NM-B(ROMEX) INTERIOR SOLARD CAT5E,ETHERNET CABLE CU CAT5E INTERIOR SOLAR SE® G G G� A B C = 12 1 1 EXTERIOR- ROOF GARAGE ELECTRICAL DIAGRAM 3.IBKW LOT#40 LENNAR: ORIGINAL BY: DESIREE WILLIAMS I DATE:15.09.24 MENIFEE HILLS 980 I DRIVE.#302 REVIEWED BY:TOM RIDGES DATE:15.09.24 - CORONNA.A.C LA A 92879 REV.# BY DATE DESCRIPTION 9 namasbe SOLAR DWG TITLE: PAGE#: SCALE: SITE LOCATION: 4571 Broadway Street INDIVIDUAL 29043 GUAVA STREET Bodtle,,,CO 80304 PLOT PLAN 2 NTS MENIFEE.CA 303.447.0300 ELECTRICAL STRUCTURAL NOTES: .SOLAR CONTRACTOR- U ALL PV ROOF ATTACHMENTS WILL BE SPACED ALONG MODULE RACKING RAILS AT NOT GREATER THAN 48-O.C. 2)ALL PV ROOF ATTACHMENTS WILL BE STAGGERED BY ROW AMONGST THE ROOF FRAMING MEMBERS,TO MAXIMUM EXTENT POSSIBLE. 3)ROOF PENETRATIONS ASSOCIATED WITH SOLAR RACKING WILL BE SEALED WITH AN APPROVED SEALANT. 4)SOLADECK WIRE TRANSITION BOX WILL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS. IT WILL BE FLASHED AND SEALED. 5)PV ARRAY WILL BE A MINIMUM OF 3'ABOVE THE COMPOSITE SHINGLE ROOF SURFACE. 6)THE UNIRAC SOLARMOUNT RACKING SYSTEM AND SOLAR PV ARRAY WILL BE INSTALLED ACCORDING TO THE UNIRAC SOLARMOUNT CODE-COMPLIANT INSTALLATION MANUAL, UN RAC TOP CLAMPSON REQUIREA ONE INCH(1 7) SPACE BETWEEN PV MODULES.SOLARMOUNT RAILS MUST EXTEND A MINIMUM OF TWO INCHES(2')BEYOND THE EDGE PA ITME OF THE PV ARRAY/SUB-ARRAY. B)UNIRAC SOLARMOUNT REQUIRES THAT A THERMAL EXPANSION GAP BE INSTALLED FOR ANY RAIL LENGTH OF GREATER THAN 40% ROOFING CONTRACTOR- U DISTANCE BETWEEN ARRAY EDGE AND TRANSITION FLASHING(COMPOSITION TO TILE)WILL BE A MINIMUM OF 3'. 2)26 GAUGE INTERLOCKING FLASHING'SIDEWALL'TO BE INSTALLED ALONG THE LENGTH OF THE PV ARRAY AT ROOFING MATERIAL TRANSITION.IT SHALL BE APROVED PRIOR TO PV SYSTEM INSTALLATION. 3)PEEL-N-STICK BASE TO BE INSTALLED ONE FOOT W)OR MORE BEYOND THE EDGE OF THE COMPOSITION SHINGLE,DOWN TO THE ROOF EAVE.PEEL-N-STICK BASE TO ` BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS. 4)AREAS UNDER EACH PV ARRAY SHALL BE ROOFED WITH COMPOSITION SHINGLE. COMPOSITION SHINGLE SHALL RUN FROM ABOVE THE PV ARRAY TO THE ROOF EAVE, 5)TILE INSTALLED BELOW THE ARRAY TO BE INSTALLED ABOVE THE COMPOSITION ROOF PER ROOFER SPECIFICATIONS. ' 6)BIRDSTOP WILL BE INSTALLED AT THE UPPERMOST TRANSITION FROM TILE TO COMPOSITION SHINGLE.BIRDSTOP TO BE SPECIFIED BY ROOFER PRIOR TO INSTALLATION. 1 he i permit We I,state Alan mustb( ELECTRICAL NOTES: GFNFRAL - O ALL PV EQUIPMENT WILL BE TLSTED AND LISTED FOk ITS USE BY A NATIONALLY RECOGNIZED TESTING LABORATORY(NRTL). 2)THE GROUNDING OF THE PHOTOVOLTAIC SYSTEM SHALL COMPLY WITH THE APPLICABLE VERSION OF THE NEC/CEC. 3)ALL GROUNDING ELECTRODE CONDUCTORS WILL BE INSTALLED IN A CONTINUOUS LENGTH EXCEPT WHERE SPLICED BY AN IRREVERSIBLE CONNECTOR OR EXOTHERMIC WELD. 4)NON-CURRENT CARRYING METAL PARTS SHALL BE CHECKED FOR PROPER GROUNDING,NOTING.THAT TERMINAL LUGS BOLTED ON AN ENCLOSURE'S FINISHED SURFACE MAY BE ELECTRICALLY INSULATED BECAUSE OF PAINT/FINISH. PAINT/FINISH AT POINT OF CONTACT SHALL BE PROPERLY REMOVED. 5)ROOF PENETRATIONS WILL BE COMPLETED AND SEALED PER APPLICABLE CODE. 6)ALL CONDUCTORS WILL HAVE A 90-C RATING TO ENSURE CODE COMPLIANCE. SOLAR CONTRACTOR- 7)MODULE CERTIFICATIONS WILL INCLUDE UL1703,IEC61646,IEC61730. 8)CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS. 9)RACEWAY POINT OF PENETRATION FROM EXTERIOR TO INTERIOR WILL BE SEALED TO PREVENT INGRESS OF WATER AND INSECTS. 10)DC WIRING IS LIMITED TO PV ARRAY FOOTPRINT W/ENPHASE MICRO-INVERTER SYSTEM. IU MODULE AND ENPHASE WIRING SHALL BE LOCATED AND SECURED UNDER THE ARRAY USING SUITABLE WIRING CLIPS.WIRING SHALL NOT MAKE CONTACT WITH THE ROOF SURFACE AND SHALL BE MANAGED IN A WORKMAN-LIKE MANNER. 12)EQUIPMENT GROUNDING CONDUCTORS WILL BE SIZED IN ACCORDANCE WITH NEC TABLE 250.122. 13)CONDUCTOR TERMINATIONS WILL BE TORQUED PER DEVICE LISTING,OR MANUFACTURER'S RECOMMENDATIONS. 14)A PV AGGREGATION PANEL(SUB PANEL)WILL NOT BE INCLUDED FOR SYSTEMS WITH ONE BRANCH CIRCUIT. 15)A DEDICATED 120V BRANCH CIRCUIT IS REQUIRED IN MASTER CLOSET(OR EQUIVALENT)FOR ENPHASE ENVOY MONITOR. SIGNAGE- 16)PV SYSTEMS SHALL BE CLEARLY MARKED IN ACCORDANCE WITH NEC ARTICLE 690 AND OTHER APPLICABLE STATE AND LOCAL CODES. 17)ALL SAFETY MARKING/PLACARDS SHALL BE PERMANENTLY ATTACHED BY ADHESIVE OR OTHER MECHANICAL MEANS. 18)MARKING/PLACARDS WILL BE METAL OR PLASTIC WITH ENGRAVED OR MACHINE PRINTED LETTERING. BACKGROUND WILL BE RED WITH WHITE CAPITAL LETTERING OF MINIMUM HEIGHT 1'. 19)ALL WIRING/RACEWAYS/JUNCTION BOXES WILL BE MARKED'PHOTOVOLTAIC POWER SOURCE;OR EQUIVALENT;WIRING/RACEWAYS SHALL BE MARKED EVERY 10'. BUILDER ELECTRICAL AND SOLAR CONTRACTORS- 20)INSTALLATION SHALL BE COMPLETED IN A NEAT AND WORKMAN-LIKE MANNER. 21)SPACE REQUIREMENTS FOR ALL ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110.26. ORIGINAL BY: DESIREE WILLIAMS DATE:15.09.24 MENIFEE HILLS LENNAR: 980 MONTECITO DRIVE,#302 REVIEWED BY: TOM FIDOES DATE:15.09.24 CORONA,CA 92879 REV.# BY DATE DESCRIPTION Vnamae;156 fOLA[ DWG TITLE: PAGE#: I SCALE: SITE LOCATION: 4571 Broadway Street INDIVIDUAL 29043 GUAVA STREET Boulder,CO 803N PLOT PLAN 3 NTS MENIFEE,CA 303.447.0300 NOTES CAUTION: POWER TO THIS BUILDING IS SUPPLIED BY THE UTILITY AND A SOLAR PV SYSTEM. DISCONNECTS ARE LOCATED AS SHOWN. WE .sra 1ty :)t on the T, T^i..F w ec a GM• exiwiaa-ceBeGEcE .Ul neren e www rcre� ryE4iFlEDEo er SERVICE BY QUALIFIED PERSONNEL ONLY CONTACT: SUNSTREET ENERGY GROUP I-877-SLR-POWR PV POWER SOURCE - AC SPECS AC OPERATING VOLTAGE: 240 V AC OPERATING CURRENT: 10.8 A NOTE: SEE MASTER SET FOR ADDITIONAL PLACARD INFORMATION ORIGINAL BY: DESIREE WILLIAMS DATE:15.09-24 LENNAR: MENIFEE HILLS REVIEWED BY:TOM FIDDES DATE:15.09.24 980 MONTECITO DRIVE.#302 CORONA.CA 92879 REV.# BV DATE DESCRIPTION namasbAI sotee DWG TITLE: PAGT*: SCALE: SITE LOCATION: 4571 Broatlway SVeet INDIVIDUAL 29043 GUAVA STREET Bol4der,CO BON PLOT PLAN 4 MENIFEE,CA 303.447.0300 PLACARDS