Loading...
PMT15-03409 City of Menifee Permit No.: PMT15-03409 29714 HAUN RD.'tXCCELA— MENIFEE,CA 92586 Type: Residential Electrical MENIFEE Date Issued: 1 110 612 01 5 PERMIT Site Address: 29064 GUAVA ST, MENIFEE, CA 92584 Parcel Number: 333-631-019 Construction Cost: $8,017.20 Existing Use: Proposed Use: Description of SOLAR TR-31582-1 MENIFEE HILLS Work: 3,18 KVV 12 MODULES LOT 29 Owner Contractor LENNAR HOMES OF CA, INC LENNAR HOMES OF CALIFORNIA INC 980 MONTECITO DR#302 25 ENTERPRISE CORONA, CA 92879 ALISO VIEJO,CA 92656 Applicant Phone: 9493498269 JEREMIAH ACAYTURRI License Number:728102 LENNAR HOMES OF CALIFORNIA INC 25 ENTERPRISE ALISO VIEJO, CA 92656 Fee Description Qtv Amount M) Solar, Residential or Small Commercial 1 252.00 Building Permit Issuance 1 27.00 GREEN FEE 1 1.00 SMIP RESIDENTIAL 1 2.00 General Plan Maintenance Fee-Electrical 1 12.60 $294.60 The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and specifications or from preventing building operations being carried on thereunder when in violation of the Building Code or of any other ordinance of City of Menifee.Except as otherwise stated,a permit for construction under which no work is commenced within six months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be forfeited. AA_Bldg_Pernit Template.rpt Page 1 of 1 ABUILDING & SAFETY PERMIT/PLAN CHECK PPLICATION Menifee DATE 10128/2015 PERMIT/PLAN CHECK NUMBER TYPE: [-I COMMERCIAL ❑✓ RESIDENTIAL ❑MULTI-FAMILY ❑MOBILE HOME ❑POOL/SPA [-]SIGN SUBTYPE: ❑✓ ADDITION ❑ALTERATION []DEMOLITION ❑ELECTRICAL []MECHANICAL ❑NEW ❑PLUMBING ❑RE-ROOF-NUMBER OF SQUARES DESCRIPTION OF WORK SOLAR PERMIT-Plan 2033X-3.18 kW 1 12 PCS Master Solar Plan#PMT14-00706 PROJECTADDRESS 29064 Guava St, Menifee,CA 92584 ASSESSOR'S PARCEL NUMBER 333-631-019 LOT 29 TRACT 31582-1 PROPERTY OWNER'S NAME Lennar Homes of California,.Inc. ADDRESS 980 Montecito Dr.,Suite 302 PHONE (951)817-3680 EMAIL jeremiah.acayturri@lennar.com APPLICANT NAME Lennar Homes of California, Inc. ADDRESS 980 Montecito Dr.,Suite 302, Corona, CA 92879 PHONE (951)817-3680 EMAIL jeremiah.acayturri@lennar.com CONTRACTOR'S NAME Lennar Homes of California, Inc, OWNER BUILDER? ❑✓ YES❑NO BUSINESS NAME Lennar Homes of California, Inc. ADDRESS 980 Montecito Dr., Suite 302, Corona, CA 92879 PHONE (951)817-3680 EMAIL jeremiah.acayturri@lennar.com CONTRACTOR'S STATE LIC NUMBER 728102 LICENSE CLASSIFICATION A&B VALUATION$ $8,017.20 FT L SO FT APPLICANT'S SIGNATURE DATE 10 2 DEPARTMENT DISTRIBUTION CITY OF MENIFEE BUSINESS LICENSE NUMBER BUILDING PLANNING ENGINEERING FIRE GREEN I I SMIP INVOICE / 6.() PAID AMOUNT AMOUNT _I OCASH O CHECK# OCREDIT CARD VISA/MC PLAN CHECK FEES PAIDAMOUNT OCASH OCHECK# OCREDITCARD VISA/MC OWNER BUILDER VERIFIED OYES O NO DL NUMBER NOTARIZED LETTER O YES O NO City of Menifee Building&Safety Department 29714 Haun Rd. Menifee, CA 92586 951-672-6777 www.cityofinenifee.us Inspection Request Line 951-246-6213 SYSTEM INFORMATION BUYER ACKNOWLEDGES THAT THE SOLAR MODULES TO BE INSTALLED ITEM 1 OTY MFR. MODEL ON THE ROOF OF THE HOME WILL BE SUBSTANTIALLY IN THE SYSTEM SIZE 3.18 NW LOCATIONS INDICATED BY THE ILLUSTRATION. MODULE 1 12 PCS.1 HYUNDAI I HIS-S265RG(265W) BUYER:INVERTER 1 12 PCS.I ENPHASE 1 M215-60-2LL-S22-IG IY'E ROOF TYPE TILE W/COMPOSITE SHINGLE UNDER ARRAY DATE: `q SUB-ARRAY INFORMATION .r ARRAY#1 ARRAY#2 ARRAY#3 .51JICDI G A MOO OTY 12 NA NA City of MenifBe BUYER: - 1' TILT 23° NA' NA. Building Dept DATE: N A PR( AZIMUTH I 91° I NA' I NA' NOV 0 4 I REVIEWEDg� Recei1) A 1 uproval of th plan approval of,any v olatlol regulations and orInanc jobsiteuntilcomp lion° r l I f I I I I I I I I I I I I I j I I I I I I I I I I I SOLADECK WIRE TRANSITION BOX (UNDER ARRAY) z a_ I Qa LL PAC DISCONNECT EXTERIOR-GARAGE UTILITY METER& MAIN SERVICE PANEL _ (VERIFIED BY BUILDER) L 3' I0'-I0" NOTE:DIMENSIONS ARE SHOWN IN PLANE OF ROOF N PLAN TATI ELEVATION A ORIENTATION 2 LO #29 ORIGINAL BY: DESIREE WILLIAMS DATE:I5.09.24 MENIFEE HILLS LENNAR: 980MONTECITO DRIVE,#302 REVIEWED BY:TOM FIDDES DATE:15.09.24 CORONA.CA 92879 REV.# BY DATE DESCRIPTION �Pnomast;d DWG TITLE: PAGE#: SCALE: SITE LOCATION: 4571 Bmo ay Street INDIVIDUAL 29064 GUAVA STREET Boulder,CO 80304 PLOT PLAN I I/16'=1',0' MENIFEE.CA 303.447.0300 SYSTEM LAYOUT MODULE SPECS AND CALCULATIONS INVERTER SPECS AND CALCULATIONS ITEM NOTE/CALC UNIT DETAIL ITEM NOTE/CALC UNIT DETAIL LOCATION MENIFEE,CA INV.MAKE INVERTER SPEC ENPHASE TEMP.AMBIENT HIGH(TMAX) ASHRAE 2% °C 37 INV.MODEL INVERTER SPEC M215-6D-2LL-S22-IG TEMP,AMBIENT LOW(THIN) ASHRAE EXTR.MIN -C -2 INV.MAX POWER,(WAC MAX) INVERTER SPEC WATTS(AC) 225 TEMP,MODULE TEST(TTSST) MODULE SPEC °C 25 INV.INPUT V,(VOO MAX) INVERTER SPEC VOLTS(DD) 48 TEMP.DELTA LOW(TDECTA) TMIN-TTSST •C -27 INV.OUTPUT V.(VAC NOM) INVERTER SPEC VOLTS(AC) 240 FET MOD.MANUFACTURER MODULE SPEC HYUNDAI INV.OUTPUT FREQUENCY INVERTER SPEC HERTZ 60 MOD.PART NUMBER MODULE SPEC HIS-S265RG INV.OUTPUT CURRENT,IAC INVERTER SPEC AMPS(AC) 0.9 MOD.POWER STC(P) MODULE SPEC WATTS(DC) 265 INV.PHASE QUANTITY INVERTER SPEC PHASE I MOD'.POWER PTC MODULE SPEC WATTS(OC) 238 COMPLIANCE INVERTER SPEC UL1741/IEEE1547 MOD.OPERATING VOLTAGE(VMP) MODULE SPEC VOLTS(DC) 31.30 INV. GROUNDING INVERTER SPEC ISOLATED MOD.OPEN CCT. VOLTAGE(VOC) MODULE SPEC VOLTS(DC) 38.10 INV.OTY.MAX/BRANCH CCT. INV.OTYec CITY 12 MOD.COEFF.VOLT/TEMP(CLEF) MODULE SPEC V/°C -0.114 BRANCH CCT.OUTPUT,IMAXBC I(IAC-INV.OT"C) I AMPS CAC) 1 10.80 MOD.MAX VOLTAGE(VMAXMOD) (Voc♦(TO°COEF)) VOLTS(DU 41.18 INV.QUANTITY,TOTAL I INV.QTYT I 9TY I12 MOD.OPERATING CURRENT(Ire) MODULE SPEC AMPS(DC) 8.50 TOTAL SYSTEM OUTPUT.MARTS I(IAC°INV.OTYT) I AMPS(AC) 10.80 MOD.SHORT CCT.CURRENT Osc) MODULE SPEC AMPS(DU 9.00 MOD.MAXIMUM CURRENT(IMAX) (Isc° 1.25) .AMPS(DC) 11.25 MIN,AMPACITY REG'0,PER NEC ([MAX. 1.25) AMPS(OC) 14.06 SERIES FUSE RATING,MAX MODULE SPEC AMPS(OD) 1 15 III nD be con ELECTRICAL EQUIPMENT SCHEDULE KEY OTV MANUFACTURER MODEL NOTES TRADE any ovfsiot 1 12 HYUNDAI HiS-S265RG(265W) PV MODULE SOLAR This tofa 2 12 ENPHASE M215-60-2LL-S22-IG PV INVERTER SOLAR �' 3 1 RSTC/SOLADECK 0786-3R5 PV ROOF JUNCTION BOX,NEMA 3R SOLAR 4 1 CUTLER-HAMMER DG221URB PV AC DISCONNECT,NEMA 3R,24OV,30A SOLAR 5 1 ENPHASE ENVOY PV DATA MONITOR,120V SOLAR 6 1 TBD TBD 120V DEDICATED RECEPTACLE FOR ENVOY PV DATA MONITOR SOLAR 7 1 TBD TBD CATS PORT FOR SOLAR PV INTERNET CONNECTION TO HOME NETWORK BOX SOLAR 8 NOTE CUTLER-HAMMER TBD PV BRANCH CIRCUIT BREAKERS:I X 15A-IP(ENVOY) SOLAR 9 NOTE CUT[ER-HAMMER TBD PV BREAKER.I x 204-2P,LOCATE AT OPPOSITE END OF RUS FROM MAIN BREAKER SOLAR 10 1 TBD TBD SERVILE PANEL,MIN. 125A BUS BLDR.ELEC, II TBD TBD UTILITY METER.IPH,120/240V,200A BLDR.ELEC. 12 1 1 1 TBD I TBD I GROUNDING ELECTRODE UFER I BLDR.ELEC. CONDUCTOR SIZING CALCULATIONS INTERCONNECTION CALCULATIONS n CONDITION OF USE(COU): I (AMPACITY°TEMP.BERATE°FILL BERATE)VB.REO'D(IMAX) ITEM UNIT PANEL 2)TERMINALS(TER I AMPACITY AT TERMINALS. y_&_REO'D,(IMAX° 1.25) PANEL HER. CUTLER-HAMMER KEY SIZE CU/AL INSULATION CALC. AMPACITY W/0 TEMP. FILL RESULT REOT OCD BUS RATING AMPS 200 TYPE DERATES BERATE DERATE (A) (A) USED(A) MAIN DISCONNECT AMPS 200 A #12 CU THWN-2 COU 30 0.76 1.0 22.80 10.80 ALLOWED PV PER NEC AMPS 40 TERM 25 1 25 13.50 20 PV OCPD DEVICE USED I AMPS 20 B #10 CU NM-B COU 40 0.91 1.0 1 36.40 10.80 TERM 35 1 35 13.50 20 C #10 Cu NM-B COU 40 0.91 1.0 36.40 10.80 TERM 35 135 13.50 20 CONDUCTOR SCHEDULE KEY CONDUCTORS CU/AL TYPE LOCATION TRADE A I-#12 ENGAGE CABLE.146G,FREE AIR I CU I TC-ER ARRAY SOLAR B 3-#10.1-#10 EGG I CU I NM-B(ROMEX) INTERIOR I SOLAR O 5 C 1 3-#10,1-#10 EGC CU I NM-B(ROMEX) INTERIOR I SOLAR © II D CAT5E,ETHERNET CABLE CU CATSE INTERIOR SOLAR Oj e o O — SEE NOTE 15 10 O 8 ISO G O O O 20A/2P G G G N � I 1 I X to - ROOF GARAGE ELECTRICAL DIAGRAM 3.16 KW LOT#29 : ORIGINAL BY: DESIREE WILLIAMS DATE:1 LENNAR 5.09.24 MENIFEE HILLS REVIEWED BY:TOM FIDDES I DATE:15.09.24 980 MONTECITO DRIVE,#302 CORONA,CA 92879 REV.# By DATE DESCRIPTION namasbe aLCAo DWG TITLE: PAGE#: SCALE: SITE LOCATION: 4577 Bro vay Street INDIVIDUAL 29064 GUAVA STREET BoWOer,CO 80304 PLOT PLAN 2 NTS MENIFEE,CA 303.447.0300 ELECTRICAL STRUCTURAL NOTES: SOLAR CONTRACTOR- S ALL PV ROOF ATTACHMENTS WILL BE SPACED ALONG MODULE RACKING RAILS AT NOT GREATER THAN 48'O.C. 2)ALL PV ROOF ATTACHMENTS WILL BE STAGGERED BY ROW AMONGST THE ROOF FRAMING MEMBERS,TO MAXIMUM EXTENT POSSIBLE. 3)ROOF PENETRATIONS ASSOCIATED WITH SOLAR RACKING WILL BE SEALED WITH AN APPROVED SEALANT. 4)SOLADECK WIRE TRANSITION BOX WILL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS. IT WILL BE FLASHED AND SEALED. (� 5)PV RAY 6)THE�UNIRAC SOLARMOUNT ILL BE A MR CK NG SYSTEM AND SOLAR PV ARRAY WILL UM OF 3'ABOVE THE COMPOS17E SHINGLE OBE IOF NSTALLED ACCORDING TO THE UNIRAC SOLARMOUNT CODE-COMPLIANT INSTALLATIDEPAR MEI MANUAL.VERSION 227.3,PUB 140113-ICC.JANUARY 2014. 7)UNIRAC TOP CLAMPS REQUIRE A ONE INCH W)SPACE BETWEEN PV MODULES.SOLARMOUNT RAILS MUST EXTEND A MINIMUM OF TWO INCHES(T)BEYOND THE EDGE OF THE PV ARRAY/SUB-ARRAY. B)UNIRAC SOLARMOUNT REQUIRES THAT A THERMAL EXPANSION GAP BE INSTALLED FOR ANY RAIL LENGTH OF GREATER THAN 40'. ROOFING CONTRACTOR- D DISTANCE BETWEEN ARRAY EDGE AND TRANSITION FLASHING(COMPOSITION TO TILE)WILL BE A MINIMUM OF Y. 2)26 GAUGE INTERLOCKING FLASHING'SIDEWALL'TO BE INSTALLED ALONG THE LENGTH OF THE PV ARRAY AT ROOFING MATERIAL TRANSITION. IT SHALL BE APROVED PRIOR TO PV SYSTEM INSTALLATION. 4� 3)PEEL-N-STICK BASE TO BE INSTALLED ONE FOOT 00 OR MORE BEYOND THE EDGE OF THE COMPOSITION SHINGLE,DOWN TO THE ROOF EAVE.PEEL-N-STICK BASE TO BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS. 4)AREAS UNDER EACH PV ARRAY SHALL BE ROOFED WITH COMPOSITION SHINGLE.COMPOSITION SHINGLE SHALL RUN FROM ABOVE THE PV ARRAY TO THE ROOF EAVE. 5)TILE INSTALLED BELOW THE ARRAY TO BE INSTALLED ABOVE THE COMPOSITION ROOF PER ROOFER SPECIFICATIONS. I I to be a 6)BIRDSTOP WILL BE INSTALLED AT THE UPPERMOST TRANSITION FROM TILE TO COMPOSITION SHINGLE. BIROSTOP TO BE SPECIFIED BY ROOFER PRIOR TO permit f INSTALLATION. the feder if,state oed plans must be ELECTRICAL NOTES: GFNFRAL - D ALL I'V LOUIPMENI WILL BE 1ESIED AND LISILD FOR ITS USL BY A NA11UNALLY HLCOGNIZLO 1LSiING LABURAIURY(NHIL). 2)THE GROUNDING OF THE PHOTOVOLTAIC SYSTEM SHALL COMPLY WITH THE APPLICABLE VERSION OF THE NEC/CEC. 3)ALL GROUNDING ELECTRODE CONDUCTORS WILL BE INSTALLED IN A CONTINUOUS LENGTH EXCEPT WHERE SPLICED BY AN IRREVERSIBLE CONNECTOR OR EXOTHERMIC WELD. 4)NON-CURRENT CARRYING METAL PARTS SHALL BE CHECKED FOR PROPER GROUNDING,NOTING THAT TERMINAL LUGS BOLTED ON AN ENCLOSURE'S FINISHED SURFACE MAY BE ELECTRICALLY INSULATED BECAUSE OF PAINT/FINISH. PAINT/FINISH AT POINT OF CONTACT SHALL BE PROPERLY REMOVED. 5)ROOF PENETRATIONS WILL BE COMPLETED AND SEALED PER APPLICABLE CODE. 6)ALL CONDUCTORS WILL HAVE A 9VC RATING TO ENSURE CODE COMPLIANCE. SOLAR CONTRACTOR- 7)MODULE CERTIFICATIONS WILL INCLUDE UL1703; IEC61646,IEC61730. 8)CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS. 9)RACEWAY POINT OF PENETRATION FROM EXTERIOR TO INTERIOR WILL BE SEALED TO PREVENT INGRESS OF WATER AND INSECTS. 10)DC WIRING IS LIMITED TO PV ARRAY FOOTPRINT W/ENPHASE MICR04NVERTER SYSTEM. 10 MODULE AND ENPHASE WIRING SHALL BE LOCATED AND SECURED UNDER THE ARRAY USING SUITABLE WIRING CLIPS. WIRING SHALL NOT MAKE CONTACT WITH THE ROOF SURFACE AND SHALL BE MANAGED IN A WORKMAN-LIKE MANNER. 12)EQUIPMENT GROUNDING CONDUCTORS WILL BE SIZED IN ACCORDANCE WITH NEC TABLE 250.122. 13)CONDUCTOR TERMINATIONS WILL BE TORQUED PER DEVICE LISTING,OR MANUFACTURER'S RECOMMENDATIONS. 14)A PV AGGREGATION PANEL(SUB PANEL)WILL NOT BE INCLUDED FOR SYSTEMS WITH ONE BRANCH CIRCUIT. 15)A DEDICATED 120V BRANCH CIRCUIT IS REQUIRED IN MASTER CLOSET(OR EQUIVALENT)FOR ENPHASE ENVOY MONITOR. SIGNAGE- 16)PV SYSTEMS SHALL BE CLEARLY MARKED IN ACCORDANCE WITH NEC ARTICLE 690 AND OTHER APPLICABLE STATE AND LOCAL CODES. 17)ALL SAFETY MARKING/PLACARDS SHALL BE PERMANENTLY ATTACHED BY ADHESIVE OR OTHER MECHANICAL MEANS. 18)MARKING./PLACARDS WILL BE METAL OR PLASTIC WITH ENGRAVED OR MACHINE PRINTED LETTERING. BACKGROUND WILL BE RED WITH WHITE CAPITAL LETTERING OF MINIMUM HEIGHT k. 19)ALL WIRING/RACEWAYS/JUNCTION BOXES WILL BE MARKED'PHOTOVOLTAIC POWER SOURCE;OR EQUIVALENT;WIRING/RACEWAYS SHALL BE MARKED EVERY 10'. BUILDER ELECTRICAL AND SOLAR CONTRACTORS- 20)INSTALLATION SHALL BE COMPLETED IN A NEAT AND WORKMAN-LIKE MANNER. 21)SPACE REQUIREMENTS FOR ALL ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110.26. LENNAR: ORIGINAL BY: DESIREE WILLIAMS DATE:I .09.24 MENIFEE HILLS 980 MONTECITO DRIVE.#302 REVIEWED BY: TOM FIDDES DATE:15.09.24 CORONA,CA 92879 REV.# BY DATE DESCRIPTION namast:d toffee DWG TITLE: PAGE#: SCALE: SITE LOCATION: INDIVIDUAL 4B7I .CO BStreet 29064 GUAVA STREET BO303.ldw4BDDD4 PLOT PLAN 3 NTS NOTES MENIFEE,CA 03.447.0300 CAUTION: POWER TO THIS BUILDING IS SUPPLIED BY THE UTILITY AND A SOLAR PV SYSTEM. DISCONNECTS ARE LOCATED AS SHOWN. DA ran Ity r on th 6.'U WIK lgdN(UAcB p% FP 19RCv1 N AC OISCWNECT EVERIW-GARLGE VRlt1Y IEIEP 6 NGIN SERVICE PPNEL IVEgRIEO BY EIICOFPI SERVICE BY QUALIFIED PERSONNEL ONLY CONTACT: SUNSTREET ENERGY GROUP I-877-SLR-POWR PV POWER SOURCE - AC SPECS AC OPERATING VOLTAGE: 240 V AC OPERATING CURRENT: Io.8 A NOTE: SEE MASTER SET FOR ADDITIONAL PLACARD INFORMATION ORIGINAL BY: DESIREE WILLIAMS DATE:15.09.24 MENIFEE HILLS LENNAR: 980 MOIJTECITO DRIVE,#302 REVIEWED BY:TOM FIDDES DATE:15.09-24 CORONA,CA 92879 REV.# BY DATE DESCRIPTION namast;e SCLA! DWG TITLE: PAGE#: I SCALE: SITE LOCATION: 4571 BE0a0way SVaat INDIVIDUAL 29054 GUAVA STREET BaUdw,,CO 803N PLOT PLAN 4 NTS PLACARDS MENIFEE,CA 303.447.0300