PMT15-03407 City of Menifee Permit No.: PMTIS-03407 29714 HAUN RD. Type: Residential Electrical '5XCCEL/-> MENIFEE, CA 92586 MENIFEE Date Issued: 11/06/2015 PERMIT Site Address: 29088 GUAVA ST, MENIFEE, CA 92584 Parcel Number: 333-631-017 Construction Cost: $10,689.00 Existing Use: Proposed Use: Description of SOLAR TR-31582-1 MENIFEE HILLS Work: 4.24 KW 16 MODULES LOT 27 Owner Contractor LENNAR HOMES OF CA, INC LENNAR HOMES OF CALIFORNIA INC 980 MONTECITO DR#302 25 ENTERPRISE CORONA, CA 92879 ALISO VIEJO, CA 92656 Applicant Phone: 9493498269 JEREMIAH ACAYTURRI License Number.728102 LENNAR HOMES OF CALIFORNIA INC 25 ENTERPRISE ALISO VIEJO, CA 92656 Fee Description QQt Amount I51 Solar, Residential or Small Commercial 1 252.00 Building Permit Issuance 1 27.00 GREEN FEE 1 1.00 SMIP RESIDENTIAL 1 2.00 General Plan Maintenance Fee-Electrical 1 12.60 $294.60 The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and specifications or from preventing builiding operations being carried on thereunder when in violation of the Building Code or of any other ordinance of City of Menifee.Except as otherwise stated,a permit for construction under which no work is commenced within six months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be forfeited. AA_Bldg_Permit_Template.rpt Page 1 of 1 BUILDING & SAFETY PERMIT/PLAN • l APPLICATION Menifee DATE 10/28/2015 PERMIT/PLAN CHECK NUMBER C 1 V5—0,75 Ql TYPE: [:]COMMERCIAL ❑✓ RESIDENTIAL [-]MULTI-FAMILY MOBILEHOME ❑.POOL/SPA ❑SIGN SUBTYPE: ❑✓ ADDITION ❑ALTERATION [—]DEMOLITION ❑ELECTRICAL [—]MECHANICAL ❑NEW [—]PLUMBING ❑RE-ROOF-NUMBER OF SQUARES DESCRIPTION OF WORK SOLAR PERMIT-Plan 3404-4.24kW/16 PCS Master Solar Plan#PMT14-00706 PROJECTADDRESS 29088 Guava St, Menifee, CA 92584 ASSESSOR'S PARCEL NUMBER 333-631-017 LOT 27 TRACT 31582-1 PROPERTY OWNER'S NAME Lennar Homes of California, Inc. ADDRESS 980 Montecito Dr.,Suite 302 PHONE (951)817-3680 EMAIL jeremiah.acayturri@lenner.com APPLICANT NAME Lennar Homes of California, Inc. ADDRESS 980 Montecito Dr.,Suite 302,Corona,CA 92879 PHONE (951)817-3680 EMAIL jeremiah.acayturri@lennar.com CONTRACTOR'S NAME Lennar Homes of California, Inc. OWNER BUILDER? ❑✓ YES❑NO BUSINESS NAME Lennar Homes of California, Inc. ADDRESS 980 Montecito Dr., Suite 302, Corona,CA 92879 PHONE (951)817-3680 EMAIL leremiah.acayturri@lennar.com CONTRACTOR'S STATE LIC NUMBER 728102 LICENSE CLASSIFICATION A&B VALUATION$ $ 10,689.00 SO FT L SQ FT APPLICANT'S SIGNATURE DATE �rsrp< :m ^OF411i ' DEPARTMENT DISTRIBUTION r� CITY OF MENIFEE BUSINESS LICENSE NUMBER BUILDING PLANNING ENGINEERING FIRE I GREEN 1 SMIP INVOICE AMOUNT ,�O PAID AMOUNT OCASH ;•'CHECK# 0CREDIT CARD VISA/MC PLAN CHECK FEES PAIDAMOUNT OCASH 0CHECK# OCREDITCARD VISA/MC OWNER BUILDER VERIFIED OYES O NO DL NUMBER NOTARIZED LETTER O YES O NO City of Menifee Building&Safety Department 29714 Houn Rd. Menifee, CA 92586 951-672-6777 www.cityofinenifee.us Inspection Request Line 951-246-6213 SYSTEM INFORMATION BUYER ACKNOWLEDGES THAT THE SOLAR MODULES TO BE INSTALLED ITEM OTY MFR. 1 MODEL ON THE ROOF OF THE HOME WILL BE SUBSTANTIALLY IN THE SYSTEM SIZE 4.24 KW LOCATIONS INDICATED BY THE ILLUSTRATION. MODULE 1 16 PCS. HYUNDAI I HIS-SZ65RG(265W) I BUYER: INVERTER 1 16 PCS.1 ENPHASE I M215-60-ZLL-S22-IG ROOF TYPE I TILE W/COMPOSITE SHINGLE UNDER ARRAY I DATE: SUB-ARRAY INFORMATION ' ARRAY#I 1 ARRAY#2 1 ARRAY#3 City of Menifee I ' OF Er MOD OTY 16 NA NA BUYER: iLDIN AI TILT 23• NA' NA' Building Dept AZIMUTH I81° NA' NA- DATE: NOV 0 4 2015 PLAN A PRC Received REVIEWED B *Approval of these pla approval of,any violati 26'-0'ARRAY regulations and Aim '-4' 26'-10'FLASHING ;obsite until con,pletiof ----------- --- 7 I � SOLADECK WIRE TRANSITION BOX t (UNDER ARRAY) I y I I + c- - - - - - CV I PV AC DISCONNECT — E%TERIOR-GARAGE UTILITY METERS I'-- -----J MAIN SERVICE PANEL I (VERIFIED VI BUILDER) L NOTE:DIMENSIONS ARE SHOWN IN PLANE OF ROOF N p. PLAN 3404 ELEVATION A ORIENTATION I LOT#27 ORIGINAL BY: DESIREE WILLIAMS I DATE:1 .09.23 MENIFEE HILLS LENNAR: 980 MONTECITO DRIVE.#302 REVIEWED BY:TOM FIDDES I DATE:15.09.23 CORONA,CA 92879 REV.# BY I DATE I DESCRIPTION namaSC6 DWG TITLE: PAGE#: SCALE: SITE LOCATION: 4571 BroaGway SVeet INDIVIDUAL 2908E GUAVA STREET BoWCer,CO 80304 PLOT PLAN 1 1/I6'=1'-0' MENIFEE.CA 303A47.03DO SYSTEM LAYOUT MODULE SPECS AND CALCULATIONS INVERTER SPECS AND CALCULATIONS ITEM NOTE/CALC UNIT DETAIL ITEM NOTE/CALC UNIT DETAIL LOCATION MENIFEE,CA INV.MAKE INVERTER SPEC ENPHASE TEMP.AMBIENT HIGH(TMAX) ASHRAE 2% °C 37 INV. MODEL INVERTER SPEC M2(5-60-2L1_-S22-IG TEMP,AMBIENT LOW(TMIN) ASHRAE EXTR.MIN 'C -2 INV. MAX POWER.(WAC MAX) INVERTER SPEC WATTS(AC) 225 TEMP,MODULE TEST(TTEST) MODULE SPEC -C 25 INV. INPUT V.(VOC MAX) INVERTER SPEC VOLTS(00 48 TEMP,DELTA LOW(TOELTA) TMIN-TTEST eC -27 INV.OUTPUT V.(Vac NOM) INVERTER SPEC VOLTS(AC) 240 MOD. MANUFACTURER MODULE SPEC HYUNDAI INV.OUTPUT FREQUENCY INVERTER SPEC HERTZ 60 MOD.PART NUMBER. MODULE SPEC HIS-S265RG INV.OUTPUT CURRENT.IAC INVERTER SPEC AMPS(Ac) 0.9 MOD.POWER STC(P) MODULE SPEC WATTS(DO 265 INV.PHASE QUANTITY INVERTER SPEC PHASE I ` MOD.POWER PTC MODULE SPEC WATTS(00 238 COMPLIANCE INVERTER SPEC UL1741/IEE 5 MOD.OPERATING VOLTAGE(VMP) MODULE SPEC VOLTS(m) 31.30 INV.GROUNDING INVERTER SPEC ISOLATED MOD.OPEN CCT.VOLTAGE(Vac) MODULE SPEC VOLTS(DO 38.10 INV.QTY,MAX/BRANCH CCT. INV.QTY'cI OTY I I6 MOD.COEFF.VOLT/TEMP(COEF) MODULE SPEC V/'C -0.114 BRANCH CCT. OUTPUT,IMAXBC (IAC-INV.QTY'C) I AMPS(AC) 1 14.40 MOD. MAX VOLTAGE(VMAXMOD) (VOC+(TD'COEF)) VOLTS(DC) 41.18 INV.QUANTITY,TOTAL INV.QTYT I QTY 1 16 MOD.OPERATING CURRENT(IMP) MODULE SPEC AMPS(00 8.50 TOTAL SYSTEM OUTPUT,IMAXTS I(IAC-INV.OTYT) I AMPS(Ac) 14.40 MOD.SHORT CCT.CURRENT(Isc) MODULE SPEC AMPS(DO 9.00 / MOD. MAXIMUM CURRENT(IMAX) (ISC• 1.25) AMPS(00 11.25 MIN.AMPACITY REO'D.PER NEC (IMAX' 1.25) AMPS(DC) 14.06 SERIES FUSE RATING,MAX MODULE SPEC AMPS(00 15 ELECTRICAL EQUIPMENT SCHEDULE KEY OTY I MANUFACTURER MODEL NOTES TRADE hallnot6 Constl 1 16 HYUNDAI HIS-S265RG(265W) PV MODULE SOLAR 2 16 ENPHASE M215-60-2LL-S22-IG PVINVERTER SOLAR of any pro isions 3 1 RSTC/SOLADECK 0786-3R5 PV ROOF JUNCTION BOX.NEMA 3R SOLAR 4 1 CUTLER-HAMMER DG221URB PV AC DISCONNECT,NEMA 3R,24OV,30A SOLAR s. This set of appl 5 1 ENPHASE ENVOY PV DATA MONITOR,120V SOLAR 6 1 TBD TBD 120V DEDICATED RECEPTACLE FOR ENVOY PV DATA MONITOR SOLAR 7 1 TBD TBD CATS PORT FOR SOLAR PV INTERNET CONNECTION TO HOME NETWORK BOX SOLAR B NOTE CUTLER-HAMMER TBD PV BRANCH CIRCUIT BREAKERS; I x 15A-IP(ENVOY) SOLAR 9 NOTF CIITI.FR HAMMER T00 PV BRFAKER, I r 2nA-2P.LOCATE AT OPPOGITF PND OF BUS FROM MAIN RREAKFR SOLAR 10 1 TBD TBD SERVICE PANEL,MIN. 125A BUS BLDR.ELEC. II I TBD TBD UTILITY METER. EL IPH.120/240V,200A BLDR. EC. IZ I TiD TBD GROUNDING ELECTRODE UFER BLDR.ELEC. CONDUCTOR SIZING CALCULATIONS INTERCONNECTION CALCULATIONS 1)CONDITION OF USE(COU): (AMPACITY'TEMP.DERATE•FILL DEBATE) vs.REQ'D(IMAX) ITEM UNIT PANEL 2)TERMINALS(TERM): AMPACITY AT TERMINALS. vs.REQ'D,([MAX-1.25) PANEL MFR. CUTLER-HAMMER KEY SIZE CU/AL INSULATION CALC. AMPACITY W/O TEMP. FILL RESULT REO'D OCD BUS RATING AMPS 200 TYPE DERATES DERATE DERATE (A) (A) USED(A) MAIN DISCONNECT AMPS 200 A #12 CU THWN-2 COU 30 0.76 1.0 22.80 14.40 ALLOWED PV PER NEC AMPS 40 TERM 25 25 18.00 20 PV OCPD DEVICE USED AMPS 20 B #10 CU NM-B LOU 40 0.91 1.0 36.40 14.40 TERM 35 35 18.00 20 C #10 CU NM-B COU 40 0.91 LO 36.40 14.40 TERM 35 35 18.00 I 20 CONDUCTOR SCHEDULE KEY CONDUCTORS MAL TYPE LOCATION TRADE A I-#12 ENGAGE CABLE.1-#6G.FREE AIR CU TC-ER ARRAY SOLAR B I 3-#10, I-#10 EGC I CU NM-0(ROMEX) I INTERIOR SOLAR C 1 3410, 1410 EGL ICU NM-B(ROMEX) INTERIOR SOLAR 0 I CATSE.ETHERNET CABLE I CU CAT5E INTERIOR SOLAR 5 6 II SEE NOTE 15 0 O © I B Q 0 I2O I IN c� A B [ O HOeF EXTERIOR-GAR<GF I ELECTRICAL DIAGRAM 4.24 xW LOT#27 LENNAR: ORIGINAL BY: DESIREE WILLIAMS I DATE:15.09.23 MENIFEE HILLS 980 MONTECITO DRIVE.#302 REVIEWED BY:TOM FIDDES I DATE:15.09.23 CORONA.CA 92879 REV.# BY DATE I DESCRIPTION namaste tCIAI DWG TITLE: PAGE#: SCALE: SITE LOCATION: S71 Broadway SOeel INDIVIDUAL 29088 GUAVA STREET Budder.CO 803N PLOT PLAN 2 NTS MENIFEE,CA 303.447.0300 ELECTRICAL STRUCTURAL NOTES: SOLAR CONTRACTOR- U ALL PV ROOF ATTACHMENTS WILL BE SPACED ALONG MODULE RACKING RAILS AT NOT GREATER THAN 48'O.C. 2)ALL PV ROOF ATTACHMENTS WILL BE STAGGERED BY ROW AMONGST THE ROOF FRAMING MEMBERS.TO MAXIMUM EXTENT POSSIBLE. 3)ROOF PENETRATIONS ASSOCIATED WITH SOLAR RACKING WILL BE SEALED WITH AN APPROVED SEALANT. 4)SOLADECK WIRE TRANSITION BOX WILL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS. IT WILL BE FLASHED AND SEALED. 5)PV ARRAY WILL BE A MINIMUM OF 3'ABOVE THE COMPOSITE SHINGLE ROOF SURFACE. 6)THE UNIRAC SOLARMOUNT RACKING SYSTEM AND SOLAR PV ARRAY WILL BE INSTALLED ACCORDING TO THE UNIRAC SOLARMOUNT CODE-COMPLIANT INSTALLATION MANUAL.VERSION 227.3.PUB 140113-ICC.JANUARY 2014. p 7)UNIRAC TOP CLAMPS REQUIRE A ONE INCH(1')SPACE BETWEEN PV MODULES.SOLARMOUNT RAILS MUST EXTEND A MINIMUM OF TWO INCHES(29 BEYOND THE EDGE :p ••�� OF THE PV ARRAY/SUB-ARRAY. K 8)UNIRAC SOLARMOUNT REQUIRES THAT A THERMAL EXPANSION GAP BE INSTALLED FOR ANY RAIL LENGTH OF GREATER THAN 40'. ROOFING CONTRACTOR- n DISTANCE BETWEEN ARRAY EDGE AND TRANSITION FLASHING(COMPOSITION TO TILE)WILL BE A MINIMUM OF 3'. 2)26 GAUGE INTERLOCKING FLASHING'SIDEWALL'TO BE INSTALLED ALONG THE LENGTH OF THE PV ARRAY AT ROOFING MATERIAL TRANSITION. IT SHALL BE APROVED PRIOR TO PV SYSTEM INSTALLATION. 3)PEEL-N-STICK BASE TO BE INSTALLED ONE FOOT(I')OR MORE BEYOND THE EDGE OF THE COMPOSITION SHINGLE,DOWN TO THE ROOF EAVE.PEEL-N-STICK BASE TO BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS. 4)AREAS UNDER EACH PV ARRAY SHALL BE ROOFED WITH COMPOSITION SHINGLE. COMPOSITION SHINGLE SHALL RUN FROM ABOVE THE PV ARRAY TO THE ROOF EAVE. 5)TILE INSTALLED BELOW THE ARRAY TO BE INSTALLED ABOVE THE COMPOSITION ROOF PER ROOFER SPECIFICATIONS. 6)BIRDSTOP WILL BE INSTALLED AT THE UPPERMOST TRANSITION FROM TILE TO COMPOSITION SHINGLE. BIRDSTOP TO BE SPECIFIED BY ROOFER PRIOR TO INSTALLATION. 4o I eapern he fE deral,st Ed pl ins must ELECTRICAL NOTES: GFNERAI - )ALL PV EQUIPMENI WILL BE ILSTED AND LISIEU FOR ITS USE BY A NATIONALLY RECOGNIZED IESTING LABURAIURY(NRIL). 2)THE GROUNDING OF THE PHOTOVOLTAIC SYSTEM SHALL COMPLY WITH THE APPLICABLE VERSION OF THE NEC/CEC. 3)ALL GROUNDING ELECTRODE CONDUCTORS WILL BE INSTALLED IN A CONTINUOUS LENGTH EXCEPT WHERE SPLICED BY AN IRREVERSIBLE CONNECTOR OR EXOTHERMIC WELD. 4)NON-CURRENT CARRYING METAL PARTS SHALL BE CHECKED FOR PROPER GROUNDING,NOTING THAT TERMINAL LUGS BOLTED ON AN ENCLOSURE'S FINISHED SURFACE MAY BE ELECTRICALLY INSULATED BECAUSE OF PAINT/FINISH. PAINT/FINISH AT POINT OF CONTACT SHALL BE PROPERLY REMOVED. 5)ROOF PENETRATIONS WILL BE COMPLETED AND SEALED PER APPLICABLE CODE. 6)ALL CONDUCTORS WILL HAVE A 90-C RATING TO ENSURE CODE COMPLIANCE. SOLAR CONTRACTOR- 7)MODULE CERTIFICATIONS WILL INCLUDE UL1703,IEC61646.IEC61730. 8)CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS. 9)RACEWAY POINT OF PENETRATION FROM EXTERIOR TO INTERIOR WILL BE SEALED TO PREVENT INGRESS OF WATER AND INSECTS. 10)DC WIRING IS LIMITED TO PV ARRAY FOOTPRINT W/ENPHASE MICRO-INVERTER SYSTEM. 10 MODULE AND ENPHASE WIRING SHALL BE LOCATED AND SECURED UNDER THE ARRAY USING SUITABLE WIRING CLIPS.WIRING SHALL NOT MAKE CONTACT WITH THE ROOF SURFACE AND SHALL BE MANAGED IN A WORKMAN-LIKE MANNER. 12)EQUIPMENT GROUNDING CONDUCTORS WILL BE SIZED IN ACCORDANCE WITH NEC TABLE 250.122. 13)CONDUCTOR TERMINATIONS WILL BE TORQUED PER DEVICE LISTING.OR MANUFACTURER'S RECOMMENDATIONS. 14)A PV AGGREGATION PANEL(SUB PANEL)WILL NOT BE INCLUDED FOR SYSTEMS WITH ONE BRANCH CIRCUIT. 15)A DEDICATED 120V BRANCH CIRCUIT IS REQUIRED IN MASTER CLOSET(OR EQUIVALENT)FOR ENPHASE ENVOY MONITOR. SIGNAGE- 16)PV SYSTEMS SHALL BE CLEARLY MARKED IN ACCORDANCE WITH NEC ARTICLE 690 AND OTHER APPLICABLE STATE AND LOCAL CODES. 17)ALL SAFETY MARKING/PLACARDS SHALL BE PERMANENTLY ATTACHED BY ADHESIVE OR OTHER MECHANICAL MEANS. 18)MARKING/PLACARDS WILL BE METAL OR PLASTIC WITH ENGRAVED OR MACHINE PRINTED LETTERING. BACKGROUND WILL BE RED WITH WHITE CAPITAL LETTERING OF MINIMUM HEIGHT t. 19)ALL WIRING/RACEWAYS/JUNCTION BOXES WILL BE MARKED'PHOTOVOLTAIC POWER SOURCE;OR EQUIVALENT:WIRING/RACEWAYS SHALL BE MARKED EVERY 10'. BUILDER ELECTRICAL AND SOLAR CONTRACTORS- 20)INSTALLATION SHALL BE COMPLETED IN A NEAT AND WORKMAN-LIKE MANNER. 21)SPACE REQUIREMENTS FOR ALL ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110.26. LENNAR: ORIGINAL BY: DESIREE WILLIAMS DATE:15.09.23 MENIFEE HILLS 980 I DRIVE.#302 REVIEWED BY: TOM FIDDES DATE:15.09.23 CORONNA,A,CA 92879 REV.# BY DATE DESCRIPTION dnama MA. DWG TITLE: PAGE#: SCALE: SITE LOCATION: 457113 a ay Street INDIVIDUAL 29088 GUAVA STREET BaWOer.CO OWN PLOT PLAN 3 NTS MENIFEE,CA 303.447.0300 NOTES CAUTION: POWER TO THIS BUILDING IS SUPPLIED BY THE NT UTILITY AND A SOLAR PV SYSTEM. DISCONNECTS ARE LOCATED AS SHOWN. '11A r� DA7 E `or,or an or city (WCER eRRnrl kept on tl e Ev ec olscow+ECR ExrEaloR.ceRacE I Lin IErER e NIN SERVICE P VEL R' K.E RR RY 91M1OER1 Vp SERVICE BY QUALIFIED PERSONNEL ONLY CONTACT: SUNSTREET ENERGY GROUP 1-877-SLR-POWR PV POWER SOURCE - AC SPECS AC OPERATING VOLTAGE: 240 V AC OPERATING CURRENT: 14.4 A NOTE: SEE MASTER SET FOR ADDITIONAL PLACARD INFORMATION ORIGINAL BY: DESIREE WILLIAMS DATE:15.09.23 MENIFEE HILLS LENNAR: 980 MONTEOITO DRIVE.#302 REVIEWED BY:TOM FIDDES DATE:15.09.23 CORONA,CA 92879 REV.# BY DATE DESCRIPTION fa namasCe SOLAR DWG TITLE: PAT* KALIE: SITE LOCATION: 4571 Broadway S"el INDIVIDUAL 29088 GUAVA STREET Boulder,CO 80304 PLOT PLAN MENIFEE,CA 303.447.0300 PLACARDS