Loading...
PMT15-02873 1 City of Menifee Permit No.: PMTIS-02873 29714 HAUN RD. ' tGC►BL.% MENIFEE, CA 92586 Type: Pool/Spa-Residential MENIFEE Date Issued: 0 9/1 612 01 6 I i PERMIT Site Address: 28802 ALMONDWOOD CT, MENIFEE, CA Parcel Number: 333-680-070 92584 Construction Cost: $60,000.00 Existing Use: Proposed Use: Description of INGROUND POOL&SPA 488 SO FT,ACCENT BOULDERS Work: Owner Contractor MARK MCDONALD CALIFORNIA POOLS INC - 28802 ALMONDWOOD CT 34 WATERWORKS WAY MENIFEE, CA 92585 IRVINE, CA 92618 '.. Applicant Phone: 8002827665 PAIGE METZGER License Number: 185102 CALIFORNIA POOLS INC 34 WATERWORKS WAY IRVINE, CA 92618 Fee Description (3ty Amount I .- Building Permit Issuance 1 27.00 SMIP RESIDENTIAL 1 8.00 e an- a e $528.35 The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and specifications or from preventing building operations being carried on thereunder when in violation of the Building Code or of any other ordinance of City of Menifee. Except as otherwise stated,a permit for construction under which no work is commenced within six months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be forfeited. AA_Bltlg_Permit Template.rpt Page 1 of 1 City Of Menifee LICENSED DECLARATION ❑ I am exempt from licensure under the Contractors'State License Law for the following reason: I hereby affirm under penalty or perjury that I am licensed under provisions of Chapter 9(commencing with section 7000)of Division 3 of the Business and By my signature below I acknowledge that, except for my personal residence in Professions Cod and my license is in full force and effect. which I must have resided for at least one year prior to completion of License Class O�License No. `�( improvements covered by this permit, I cannot legally sell a structure that I have Expires Signature � ems`X-!t l� l built as an owner-building if has not been constructed In its entirety by licensed x "" � contractors. I understand that a copy of the applicable law, Section 7044 of the WORKERS'COMPENSATION DECLARATION C/ Business and Professions Code,is available upon request when this application is submitted or at the following Web site: ❑ I hereby affirm under penalty of perjury one of the following declarations: htt :/www.le info.ca. ov/calaw.hmi I have and will maintain a certificate of consent of self-insure for workers' _ compensation, issued by the Director of Industrial Relations as provided for by Date Section 3700 of the Labor Code, for the performance of work for which this permit is issued. Property Owner on Ihon ed Agent Policy# ❑ By my Signature below, I certify to each of the following: I am the property 1 have and will maintain workers' compensation insurance, as required by owner or authorized to act on the property owner's behalf. I have read this ion 3700 of the Labor Code, for the performance of the work for which this application and the information I have provided is correct. I agree to comply sectpermit is issued.My workers'compensation insurance carrier and policy number are: with all applicable city and county ordinances and stale laws relating to building //vv ,,// construction. I authorize representatives of this city or county to enter the above- Carrier 50 � de 'fed roperty for the Insp st'on purposes. _ Policy# �N k"�2--Y� p 1 Dater Expires Pr erty Owner or ut orize Agq (This section need not be completed if the permit is for City Business License# C� one-hundred dollars($100)or less) HAZARDOUS MATERIAL DECLARATION ❑ I certify that in the performance of the work for which this permit is issued,I shall not employ any persons in any manner so as to become subject to the Will the applicant or future building occupant handle hazardous material or a workers' compensation laws of California, and agree that if I should become mixture containing a hazardous material equal to or greater that the subject to the workers'compensation provisions of Section 3700 of the Labor amounts specified on the Hazardous Materials Information Guide? Code, I shall forthwith comply with those provisions. DYES ❑ NO Applicant; Date; I J Will the intended use of the building the applicant or future building occupant require a permit for the construction ruction or modification from South FAILU RE ILURE TO SECURE WORKERS' Coast Air Quality Management District(SCAQMD)?See permitting checklist COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL for guidelines SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND OYES ❑ NO CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000), IN ADDITION TO THE COST OF COMPENSATION, Will the proposed building or modified facility be within 1000 feet of the outer DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE boundary of a school? LABOR CODE, INTEREST,AND ATTORNEYS FEES BYES ❑NO CONSTRUCTION LENDING AGENCY I have read the Hazardous Material Information Guide and the SCAQMD I hereby affirm that under the penalty of perjury there is a construction lending permitting checklist. I understand my requirements under the State of agency for the performance of the work which this permit is issued (Section California Health&Safety Code,Section 25505 and 25534 concerning 3097 Civil Code) hazardous material reporting. OWNER BUILDER DECLARATIONS DYES ❑ NO - Date I hereby affirm under penalty of perjury that I am exempt from the Contractor's License Law for the reason(s)indicated below by the checkmark(s)I have placed PROPERTY OWNER OR AUTHORIZED AGENT next to the applicable item(s) (Section 7031.5. Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, EPA RENOVATION REPAIR AND PAINTING(RRP) or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the The EPA Renovation,Repair and Painting(RRP)Rule requires contractors provisions of the Contractor's State License Law (Chapter 9 (commencing with receiving compensation for most work that disturbs paint in a pre-1978 Section 7000)of Division 3 of the Business and Professions Code)or that he or residence or childcare facility to be RRP-certified firms and comply with she is exempt from Iicensure and the basis for the alleged exemption. Any required practices.This includes rental property owners and property violation of Section 7031.5 by any Applicant for a permit subjects the applicant to managers who do the paint-disturbing work themselves or through their a civil penalty of not more than($500).) employees. For more information about EPA's Renovation Program visit: www.epa.gov/lead or contact the National Lead Information Center at ❑ I, as owner of the property, or my employees with wages as their sole 1-800-424-LEAD(5323). compensation, will do ( )all of or ( ) porting of the work, and the structure is not intended or offered for sale. (Section 7044,Business and Professions Code; The Contractor's Slate License Law does not apply to an owner of a property ❑An EPA Lead-Safe Certified Renovator will be responsible for this project who, through employees' or personal effort, builds or improves the property, provided that the improvements are not Intended or offered for sale. If,however, Certified Firm Name: the building or improvement is sold within one year of completion, the Owner- Builder will have the burden of proving that it was not built or Improved for the Firm Certification No.: purpose of sale). ❑ 1, as owner of the property an exclusively contracting with licensed El No EPA Lead-Safe Certified Firm is required for this project because: contractors to construct the project(Section 7044, Business and Professions Code:The Contractor's License Law does not apply to an owner of a property who builds or improves thereon, and who contracts for the projects with a licensed contractor(s)pursuant to the Contractors State License Law). If your project does not comply with EPA RRP rule please fill out the RRP Acknowledgement. CITY OF MENIFEE PLCKNo: IM195 C 29714 Haun Road Dale: Date I� ,� Menifee, CA 92586 Phone: (951)672-6777Amount: Amo �g 3s. Fax:(951)679-3843 Ck ft. Ck# Building Combination Permit 3 SS £S To Ele Completed By Applicant Legal s pbon:U/ v�' S F: L: t case : R Prop ert�Ad�dressIm Assessor's Parcel Num OOP rOjec nantName: C OVq Z' Unit#: I Floor#: Name: A ,(oz—I4i � A _o�Ll 9h>Me.yq _ ' ,Z I Fax No. owopBrty Address:Z �t`+l A_IVVO 1 j �O d ,C ner Unit Number Zp Email Address: A , _ Name: PJgna Fax Applicant A dress ,Z ({ 1�J Cl � _ Unit NlxnP Email Addrese�7� �U Name; r� P*n Fax o eL2� � �.l Contractor Address: ci ssy�aw!I��., qqddyq Z �� ESQ Gt ✓, on rat ors ultv Uutuness tense No. Contractor's 'N t t f l la License No. n Classificatio /t P7 Number of Squares: (/ (/�✓ Square Footage Description of Work: z) S '(// pr(� Cosl of Work:$ - /'y-� Applicant's Signature (l C- L�IJ Date: i I J To Be Completed ByAefty Staff Only Indicate As R.Received or N/A-Not Applicable 5 Completes sets of fully Mmen&oned.drawn to sale plans which include: 1 set of documents which include ❑ Title Sheet ❑ Elevations ❑ Electrical Plan ❑ GOP Tech/Soils Report(on cd only) ❑ Plot/Site Plan ❑ Roof Plan ❑ Title 24 Energy(on 8 V,x 11 ❑ Mechanical Plan ) - ❑ ❑ Structural Calculations Foundation Plan ❑ Goss Section ❑ Plumbing Plan Floor Plan ❑ Single Line diagram for elec.services over 400 AMP ❑ ❑ Strttcbaal Fraring Plan d Details ❑ Shoring Plan ❑ Sound Report-Residential Class Code: Indicate L JNew Construction Alteration- Addifion' MasnarMalhods Work Type. eW Retrofit' Revbbn to b[fWrlg Regwrod? YES NO Proposed Building Use(s): Existing Building Use(s): If Buildings. 4 Units. 11 Stories: WIN the Building Have a Basement? Y of N Bldg. Code Occupancy Group At Project Indicate In,*Pvu d YES or NO Imt(cate ail Geo-tech.Haz.Zone Completion: Construction Spnnklered that apply: Coastal Zone Type(s,: C Of O YES or NO Noise Zone Required? Listed on Historic Resources Inventory CITY PLANNING STAFF ONLY APPROVALS: Costal Commies Arch.Review Board I I Landmark Conan. :]Planning Comm.Zoning Administrator Fee Exempt: City Project I Elec.Vehicle chargerl I Landmark Ssismic Retrofit pacecase wdg office, ovai Expedite Project(s): Child Care City Project Groan Building [Lk!2!mark1 Affordable Housing For Staff Use Only Budifrel/safety I Pwmil spevalst I (;ity annin G,w Emy,xienng I Admit Imnsrionatonulgint. eM Convoy THANK YOU FOR HELPING US CREATE A BETTER COMMUNITY Patrett Engineering Group, Inc. 751 Sunny Grove Lane • Glendora, CA 91741 - Phone: (626) 335-4362 • Fax: (626) 963 4812 City of Menifee bWidiny & Safety Dept. SEP 16 2015 ENGINEERING DETAILS F(jRcelved ACCENT BOULDER SURCHARGED POOL WALL DESIGN McDONALD RESIDENCE 28802 ALMOND WOOD CT MENIFEE, CA OQROFESS/oNq O f 2 u No. 32994 m EXP. 6/3 012 0 1 6 \T C P �gTFO UFO DATE: SEPTEMBER 10, 2015 ENGINEER: DOUGLAS R. FERRELL RCE # 32994, CALIFORNIA 751 SUNNY GROVE LANE ..r GLENDORA, CA 91741 (626) 335-4362 Project: �`ODNALD !?�S/a�FNG �111� Patrett 2880 C, Poo L s -- Engineering Group, Inc. Engineer: fD. FlclQ2F— LL 751 Sunny Grove Ln. PH: (626) 335-4362 Glendora, CA 91741 FAX: (626) 963-4812 Date: g 10 / '3 Sheet / of j POOL StPA Lfilour Accent boulders on bond SEAM o t°? +0 ° PETA f Ce O 8 p/a 1 Beach to Reef try, Flag entry to below aterline ° o m N FLOFESS/ Jo�ps Iz. Pool- .�E:/Gaf�I k f� Fag i 47,Jk AL 8OV L CA � No. 32994 r �; I A URCW f IL G� Old as m c� BEAM * EXP. 6/30/2016 � `rq 1VIL �F oa 21 P'Qt- (7EPT4/5 ✓ "P" X 8 ,011 AU Project: R . 014A LO �I11w Patiooeo� ll 28802 A °N°W°00 e7- Engineering Group, Inc. �P�'EGI Engineer 751 Sunny Grove Ln. PH: (626) 335-4362 Glendora, CA 91741 FAX: (626) 963-4812 Date: 9 /° /s Sheet_ of _62 NATURAL ROCK ON BOND BEAM? SOIL EFP = 6O f=Cr- NOTES, I. CONCRETE: r'c - 2,500 pal MIN., 26 DAYS 2. STEEL: A4015 GRADE 40 BARS NATURAL BOULDER 3'x3' MAX. (3) 04 CONT, ISOLATION MATERIAL CTYP.) IF DECK IS PRESENT 13 0 12' oz.TYP HORIZ \ _ VERTICAL REINF. �n SEE TABLE \ p m J 3" CLR TYP. Y SEE TABLE Q 'do' SEE TABLE z w '9 0 12"O.C.TYP. IN FLOOR / y.. 40 BAR DIA \ LAP TYP. �18.�f POOL 'T' 'de' VERTICAL TRANSITION DEPTH REINFORCEMENT LENGTH 0' - 2'-0' W 3' •3 0 12' oz. 3.-0. 3. 03 0 6 oz, 3' 03 0 W C.C. --� �OQROFESS/pN9 4'-0' -1' 4' "3 0 6' oz. 5. 03 0 4' oz. N0. 32994 f m 03 0 4' o.c. EXP. A 6/30/2016 11-01 10, ,, "3 0 12' oz;. �4 + (2)04 PER FT. 9 \P 03 0 12' oz, AL1F + (2) 04 PER FT. Project: -IWIDOAIA4. ) � Pa t re l l -- 2��°� -- �oa� s Engineering Group, Inc. Engineer: D• FE112-RFIC. 751 Sunny Grove Ln. PR (626) 335-4362 Glendora, CA 91741 FAX: (626) 963-4812 Date: O 1 S Sheet_ ofIf [LI At 3'-0" Depth B := 2.92ft (Wall Height to Critical Point) (Soil) (Rock Surcharge) 1.6•EFP-B3.1ft 1•2'Whorizsurcharge'1ft•B 2 mu := 6 + 2 = 1158ft-lb b := 12in t := 6in cis := 3in F :_ = 0.009 12000in 3 Mu 10001b-ft) Ku F 129 p := 0.0038 As := p•b.ds = 0.137•in2 #3 @ 6" o.c. As = 0,22 in2 > 0.137 in2 @ D = 3'-0" t = 6-in ds = 3•in #3 @ 6" o.c. Vertical At 3'-6" Depth B := 3.42ft (Wall Height to Critical Point) (Soil) (Rock Surcharae) 1.6-EFP-B3.1ft 1•2'whorizsurcharge' 2 1ft•B Mu 6 + 2 = 1682ft•lb b := 12in t := 6in ds := 3in F :_ b ds2 = 0.009 12000in3 ( Mu T-0-0-01bift)KuF 187 p := 0.0055 OoeR�S RSslpN9l As := p b 2 ds = 0.198•in No. 32994 R * EXP. 6/30/2016 #3 @ 6" o.c. As = 0.22 in2 > 0.198 in2 CAL' @ D = 3'-6" t = 6in ds = 3•in #3 @ 6" o.c. Vertical - Project: /'7 OOe/p 1-0 i?ems . Patrett28802 xl ✓y /Ly jrVO06 G7' __ _ IDoOL -- Engineering Group, Inc. Engineer: . fEZ f:l 751 Sunny Grove Ln. PH: (626) 335-4362 Glendora, CA 91741 FAX: (626) 963-4812 Date: 9 / i l;— Sheet y of At 4'-0" Depth B := 3.92ft (Wall Height to Critical Point) (Soil) (Rock Surcharge) 1.6-EFP•B3.1ft 1.2'whorizsurcharge•1ft'B2 Mu + = 2333ft•Ib 6 2 b b := 12in t := 7in ds := 4in F :— ds2 = 0.016 M 12000in3 u 10001b•ft) Ku := F 146 p := 0.0043 As := p•b•ds = 0.206•in2 #3 @ 6" o.c. As = 0.22 in2 > 0.206 in2 @ D = 4'-0" t = Tin ds = 4-in #3 @ 6" o.c. Vertical At 5'-0" Depth B := 4.76ft (Wall Height to Critical Point) (Soil) (Rock Surcharge) 1.6-EFP•B3.1ft 1.2'whorizsurcharge'1ft•B2 Mu 6 + 2 = 3744ft•lb b ds2 b := 12in t := 8in ds := 5in F :_ = 0.025 M 12000in3 u 10001b•ft) Ku 150 p := 0.0044 OQROFESS/Oh F Q, Jc) S R.O FFR q(F� 2 e a As := p•b-ds = 0.264•in NO. 32994 f R * EXP. 6/3012016 #3 @ 4" o.c. As = 0.33 in2 > 0.264 in2 sp AUK @D = 5'-0" t = 8•in cis = 5-in #3@4" o.c. Project: �1CDons�tva �'LS �A11� Patrett Engineering Group, Inc. Engineer: 751 Sunny Grove Ln. PH: (626) 335-4362 �, Glendora, CA 91741 FAX: (626) 963-4812 Date: / ✓S® Sheet i of At 6'-0" Depth B := 5.60ft (Wall Height to Critical Point) (Soil) (Rock Surcharge) :— 1.6•EFP-B3.1ft 2 Mu + 1.2'whorizsurcharge•1ft•B = 5604ft•Ib 6 2 b ds2 b := 12in t := 9in ds := 6in F :_ = 0.036 12000in 3 Mu 10001b•ft) Ku := F 156 p := 0.0045 As := p•b-ds = 0.324•in2 #3 @ 4" o.c. As = 0.33 in2 > 0.324 in2 @ D = 6'-0" t = 9-in ds = 6-in #3 @ 4" o.c. Vertical At 7'-0" Depth B := 6.44ft (Wall Height to Critical Point) (Soil) (Rock Surcharge) 2 Mu 1.6•EFP-B3.1ft + 1.2'whorizsurcharge'1ft•B 7969ft lb 6 2 b ds2 b := 12in t := 10in ds := Tin F :_ = 0.049 M 12000in 3 u1 K 10001b•ft) = 163 ?ROFESS/- u F p := 0.0048 e`� P R. O^�9 `4 OJG� FFRp As := p•b-cl = 0.4•in2 No. 32994 * EXP. 6/30/2016 � #3 @ 12" o.c. + (2) #4 As = 0.51 in2 > 0.4 in2 sqT @ D = T-0" t = 10•in ds = 7•in CA!.'. #3 12" o.c. w/ 2 #4 Between Vertical Project: tilaDon/4 Z i7.e 4 . Patrell Engineering Group, Inc. Pool S 751 Sunny Grove Ln. PH: (626) 335 4362 Engineer: ® AIC4)4I . e4 Glendora, CA 91741 FAX: (626) 963-4812 Date: 91 '�7 Sheet (D of �O At 8'-0" Depth B := 7.27ft (Wall Height to Critical Point) (Soil) (Rock Surcharge) 1.6•EFP•B3.1ft 1.2'whorizsurcharge'1ft•B2 Mu 6 + =2 10857ft•lb b ds2 b := 12in t := 11 in ds := 81n F :_ = 0.064 M 12000in 3 u 10001b•ft Ku �F = 170 p := 0.005 As := p•b•ds = 0.48•in2 #3 @ 12" o.c. + (2) #4 As = 0.51 in2 > 0.48 in2 @ D = 8'-0" t = 11 -in ds = 8-in #3 @ 12" O.C. w/ (2) #4 Between Vertical rO FESS/pN.S R.FFR l!1 b , 'U No. 32994 �F EXP. 6/30/2016 /,