PMT15-02873 1
City of Menifee Permit No.: PMTIS-02873
29714 HAUN RD.
' tGC►BL.% MENIFEE, CA 92586 Type: Pool/Spa-Residential
MENIFEE Date Issued: 0 9/1 612 01 6
I
i
PERMIT
Site Address: 28802 ALMONDWOOD CT, MENIFEE, CA Parcel Number: 333-680-070
92584 Construction Cost: $60,000.00
Existing Use: Proposed Use:
Description of INGROUND POOL&SPA 488 SO FT,ACCENT BOULDERS
Work:
Owner Contractor
MARK MCDONALD CALIFORNIA POOLS INC -
28802 ALMONDWOOD CT 34 WATERWORKS WAY
MENIFEE, CA 92585 IRVINE, CA 92618 '..
Applicant Phone: 8002827665
PAIGE METZGER License Number: 185102
CALIFORNIA POOLS INC
34 WATERWORKS WAY
IRVINE, CA 92618
Fee Description (3ty Amount
I .-
Building Permit Issuance 1 27.00
SMIP RESIDENTIAL 1 8.00
e an- a e
$528.35
The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and
specifications or from preventing building operations being carried on thereunder when in violation of the Building Code or of any other
ordinance of City of Menifee. Except as otherwise stated,a permit for construction under which no work is commenced within six
months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be
forfeited.
AA_Bltlg_Permit Template.rpt Page 1 of 1
City Of Menifee
LICENSED DECLARATION ❑ I am exempt from licensure under the Contractors'State License Law for the
following reason:
I hereby affirm under penalty or perjury that I am licensed under provisions of
Chapter 9(commencing with section 7000)of Division 3 of the Business and By my signature below I acknowledge that, except for my personal residence in
Professions Cod and my license is in full force and effect. which I must have resided for at least one year prior to completion of
License Class O�License No. `�( improvements covered by this permit, I cannot legally sell a structure that I have
Expires Signature � ems`X-!t l� l built as an owner-building if has not been constructed In its entirety by licensed
x "" � contractors. I understand that a copy of the applicable law, Section 7044 of the
WORKERS'COMPENSATION DECLARATION C/ Business and Professions Code,is available upon request when this application is
submitted or at the following Web site:
❑ I hereby affirm under penalty of perjury one of the following declarations: htt :/www.le info.ca. ov/calaw.hmi
I have and will maintain a certificate of consent of self-insure for workers' _
compensation, issued by the Director of Industrial Relations as provided for by Date
Section 3700 of the Labor Code, for the performance of work for which this
permit is issued. Property Owner on Ihon ed Agent
Policy# ❑ By my Signature below, I certify to each of the following: I am the property
1 have and will maintain workers' compensation insurance, as required by owner or authorized to act on the property owner's behalf. I have read this
ion 3700 of the Labor Code, for the performance of the work for which this application and the information I have provided is correct. I agree to comply
sectpermit is issued.My workers'compensation insurance carrier and policy number are: with all applicable city and county ordinances and stale laws relating to building
//vv ,,// construction. I authorize representatives of this city or county to enter the above-
Carrier 50 � de 'fed roperty for the Insp st'on purposes. _
Policy# �N k"�2--Y� p 1 Dater
Expires
Pr erty Owner or ut orize Agq
(This section need not be completed if the permit is for City Business License# C�
one-hundred dollars($100)or less)
HAZARDOUS MATERIAL DECLARATION
❑ I certify that in the performance of the work for which this permit is issued,I
shall not employ any persons in any manner so as to become subject to the Will the applicant or future building occupant handle hazardous material or a
workers' compensation laws of California, and agree that if I should become mixture containing a hazardous material equal to or greater that the
subject to the workers'compensation provisions of Section 3700 of the Labor amounts specified on the Hazardous Materials Information Guide?
Code, I shall forthwith comply with those provisions. DYES ❑ NO
Applicant; Date; I J Will the intended use of the building the applicant or future building
occupant require a permit for the construction
ruction or modification from South
FAILU
RE ILURE TO SECURE WORKERS' Coast Air Quality Management District(SCAQMD)?See permitting checklist
COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL for guidelines
SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND OYES ❑ NO
CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS
($100,000), IN ADDITION TO THE COST OF COMPENSATION, Will the proposed building or modified facility be within 1000 feet of the outer
DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE boundary of a school?
LABOR CODE, INTEREST,AND ATTORNEYS FEES BYES ❑NO
CONSTRUCTION LENDING AGENCY I have read the Hazardous Material Information Guide and the SCAQMD
I hereby affirm that under the penalty of perjury there is a construction lending permitting checklist. I understand my requirements under the State of
agency for the performance of the work which this permit is issued (Section California Health&Safety Code,Section 25505 and 25534 concerning
3097 Civil Code) hazardous material reporting.
OWNER BUILDER DECLARATIONS DYES ❑ NO -
Date
I hereby affirm under penalty of perjury that I am exempt from the Contractor's
License Law for the reason(s)indicated below by the checkmark(s)I have placed PROPERTY OWNER OR AUTHORIZED AGENT
next to the applicable item(s) (Section 7031.5. Business and Professions Code:
Any city or county that requires a permit to construct, alter, improve, demolish, EPA RENOVATION REPAIR AND PAINTING(RRP)
or repair any structure, prior to its issuance, also requires the applicant for the
permit to file a signed statement that he or she is licensed pursuant to the The EPA Renovation,Repair and Painting(RRP)Rule requires contractors
provisions of the Contractor's State License Law (Chapter 9 (commencing with receiving compensation for most work that disturbs paint in a pre-1978
Section 7000)of Division 3 of the Business and Professions Code)or that he or residence or childcare facility to be RRP-certified firms and comply with
she is exempt from Iicensure and the basis for the alleged exemption. Any required practices.This includes rental property owners and property
violation of Section 7031.5 by any Applicant for a permit subjects the applicant to managers who do the paint-disturbing work themselves or through their
a civil penalty of not more than($500).) employees. For more information about EPA's Renovation Program visit:
www.epa.gov/lead or contact the National Lead Information Center at
❑ I, as owner of the property, or my employees with wages as their sole 1-800-424-LEAD(5323).
compensation, will do ( )all of or ( ) porting of the work, and the structure is
not intended or offered for sale. (Section 7044,Business and Professions Code;
The Contractor's Slate License Law does not apply to an owner of a property ❑An EPA Lead-Safe Certified Renovator will be responsible for this project
who, through employees' or personal effort, builds or improves the property,
provided that the improvements are not Intended or offered for sale. If,however, Certified Firm Name:
the building or improvement is sold within one year of completion, the Owner-
Builder will have the burden of proving that it was not built or Improved for the Firm Certification No.:
purpose of sale).
❑ 1, as owner of the property an exclusively contracting with licensed El No EPA Lead-Safe Certified Firm is required for this project because:
contractors to construct the project(Section 7044, Business and Professions
Code:The Contractor's License Law does not apply to an owner of a property
who builds or improves thereon, and who contracts for the projects with a
licensed contractor(s)pursuant to the Contractors State License Law). If your project does not comply with EPA RRP rule please fill out the RRP
Acknowledgement.
CITY OF MENIFEE PLCKNo: IM195 C
29714 Haun Road Dale: Date I� ,�
Menifee, CA 92586
Phone: (951)672-6777Amount: Amo �g 3s.
Fax:(951)679-3843 Ck ft. Ck#
Building Combination Permit 3 SS
£S To Ele Completed By Applicant
Legal s pbon:U/ v�' S F: L: t
case
: R
Prop ert�Ad�dressIm Assessor's Parcel Num OOP
rOjec nantName: C OVq Z' Unit#: I Floor#:
Name: A ,(oz—I4i � A _o�Ll 9h>Me.yq _ ' ,Z I Fax No.
owopBrty Address:Z �t`+l A_IVVO 1 j �O d ,C ner
Unit Number Zp
Email Address: A , _
Name: PJgna Fax
Applicant A dress ,Z ({
1�J Cl � _ Unit NlxnP
Email Addrese�7� �U
Name; r� P*n Fax o eL2� � �.l
Contractor Address: ci ssy�aw!I��., qqddyq
Z �� ESQ Gt ✓,
on rat ors ultv Uutuness tense No. Contractor's 'N t t f l la License No. n Classificatio /t P7
Number of Squares: (/ (/�✓
Square Footage
Description of Work: z) S '(// pr(� Cosl of Work:$ - /'y-�
Applicant's Signature (l C- L�IJ
Date:
i I J
To Be Completed ByAefty Staff Only
Indicate As R.Received or N/A-Not Applicable
5 Completes sets of fully Mmen&oned.drawn to sale plans which include: 1 set of documents which include
❑ Title Sheet ❑ Elevations ❑ Electrical Plan ❑ GOP Tech/Soils Report(on cd only)
❑ Plot/Site Plan ❑ Roof Plan ❑ Title 24 Energy(on 8 V,x 11
❑ Mechanical Plan )
- ❑ ❑ Structural Calculations
Foundation Plan ❑ Goss Section ❑ Plumbing Plan
Floor Plan ❑ Single Line diagram for elec.services over 400 AMP
❑ ❑ Strttcbaal Fraring Plan d Details ❑ Shoring Plan ❑ Sound Report-Residential
Class Code: Indicate L JNew Construction Alteration- Addifion' MasnarMalhods
Work Type. eW Retrofit' Revbbn to b[fWrlg Regwrod? YES NO
Proposed Building Use(s): Existing Building Use(s):
If Buildings. 4 Units. 11 Stories: WIN the Building Have a Basement?
Y of N
Bldg. Code Occupancy Group At Project Indicate In,*Pvu d YES or NO Imt(cate ail Geo-tech.Haz.Zone
Completion: Construction Spnnklered that apply: Coastal Zone
Type(s,: C Of O YES or NO Noise Zone
Required? Listed on Historic Resources Inventory
CITY PLANNING STAFF ONLY
APPROVALS: Costal Commies Arch.Review Board I I Landmark Conan. :]Planning Comm.Zoning Administrator
Fee Exempt: City Project I Elec.Vehicle chargerl I Landmark Ssismic Retrofit pacecase wdg
office, ovai
Expedite Project(s): Child Care City Project Groan Building [Lk!2!mark1 Affordable Housing
For Staff Use Only
Budifrel/safety I Pwmil spevalst I (;ity annin G,w Emy,xienng I Admit Imnsrionatonulgint. eM Convoy
THANK YOU FOR HELPING US CREATE A BETTER COMMUNITY
Patrett
Engineering Group, Inc.
751 Sunny Grove Lane • Glendora, CA 91741 - Phone: (626) 335-4362 • Fax: (626) 963 4812
City of Menifee
bWidiny & Safety Dept.
SEP 16 2015
ENGINEERING DETAILS F(jRcelved
ACCENT BOULDER SURCHARGED
POOL WALL DESIGN
McDONALD RESIDENCE
28802 ALMOND WOOD CT
MENIFEE, CA
OQROFESS/oNq
O f 2
u No. 32994 m
EXP. 6/3 012 0 1 6
\T C P
�gTFO UFO
DATE: SEPTEMBER 10, 2015
ENGINEER: DOUGLAS R. FERRELL
RCE # 32994, CALIFORNIA
751 SUNNY GROVE LANE ..r
GLENDORA, CA 91741
(626) 335-4362
Project: �`ODNALD !?�S/a�FNG
�111� Patrett 2880
C, Poo L s
-- Engineering Group, Inc.
Engineer: fD. FlclQ2F— LL
751 Sunny Grove Ln. PH: (626) 335-4362
Glendora, CA 91741 FAX: (626) 963-4812 Date: g 10 / '3 Sheet / of j
POOL StPA Lfilour
Accent boulders on bond SEAM
o t°? +0
° PETA f Ce O
8
p/a 1 Beach to Reef try, Flag
entry to below aterline
° o
m
N
FLOFESS/
Jo�ps Iz.
Pool- .�E:/Gaf�I k f� Fag i 47,Jk AL 8OV L CA � No. 32994 r �;
I A
URCW f IL G� Old as m c� BEAM * EXP. 6/30/2016 �
`rq 1VIL �F
oa
21 P'Qt- (7EPT4/5 ✓ "P" X 8 ,011 AU
Project: R . 014A LO
�I11w Patiooeo� ll 28802 A °N°W°00 e7-
Engineering Group, Inc. �P�'EGI
Engineer
751 Sunny Grove Ln. PH: (626) 335-4362
Glendora, CA 91741 FAX: (626) 963-4812 Date: 9 /° /s Sheet_ of _62
NATURAL ROCK ON BOND BEAM?
SOIL EFP = 6O f=Cr-
NOTES,
I. CONCRETE: r'c - 2,500 pal
MIN., 26 DAYS
2. STEEL: A4015 GRADE 40 BARS
NATURAL BOULDER
3'x3' MAX.
(3) 04 CONT,
ISOLATION MATERIAL CTYP.)
IF DECK IS PRESENT
13 0 12' oz.TYP HORIZ \ _
VERTICAL REINF. �n
SEE TABLE \ p m
J
3" CLR TYP.
Y SEE TABLE Q
'do' SEE TABLE z w
'9 0 12"O.C.TYP.
IN FLOOR
/ y..
40 BAR DIA
\ LAP TYP.
�18.�f
POOL 'T' 'de' VERTICAL TRANSITION
DEPTH REINFORCEMENT LENGTH
0' - 2'-0' W 3' •3 0 12' oz.
3.-0. 3. 03 0 6 oz,
3' 03 0 W C.C. --�
�OQROFESS/pN9
4'-0' -1' 4' "3 0 6' oz.
5. 03 0 4' oz.
N0. 32994 f m
03 0 4' o.c. EXP. A
6/30/2016
11-01 10, ,, "3 0 12' oz;. �4
+ (2)04 PER FT. 9 \P
03 0 12' oz, AL1F
+ (2) 04 PER FT.
Project: -IWIDOAIA4. )
� Pa t re l l -- 2��°� --
�oa� s
Engineering Group, Inc.
Engineer: D• FE112-RFIC.
751 Sunny Grove Ln. PR (626) 335-4362
Glendora, CA 91741 FAX: (626) 963-4812 Date: O 1 S Sheet_ ofIf
[LI
At 3'-0" Depth B := 2.92ft (Wall Height to Critical Point)
(Soil) (Rock Surcharge)
1.6•EFP-B3.1ft 1•2'Whorizsurcharge'1ft•B
2
mu := 6 + 2 = 1158ft-lb
b := 12in t := 6in cis := 3in F :_ = 0.009
12000in 3
Mu
10001b-ft)
Ku F 129 p := 0.0038
As := p•b.ds = 0.137•in2
#3 @ 6" o.c. As = 0,22 in2 > 0.137 in2
@ D = 3'-0" t = 6-in ds = 3•in #3 @ 6" o.c. Vertical
At 3'-6" Depth B := 3.42ft (Wall Height to Critical Point)
(Soil) (Rock Surcharae)
1.6-EFP-B3.1ft 1•2'whorizsurcharge' 2
1ft•B
Mu 6 + 2 = 1682ft•lb
b := 12in t := 6in ds := 3in F :_ b ds2 = 0.009
12000in3
( Mu
T-0-0-01bift)KuF 187 p := 0.0055 OoeR�S RSslpN9l
As := p b
2
ds = 0.198•in No. 32994 R
* EXP. 6/30/2016
#3 @ 6" o.c. As = 0.22 in2 > 0.198 in2
CAL'
@ D = 3'-6" t = 6in ds = 3•in #3 @ 6" o.c. Vertical -
Project: /'7 OOe/p 1-0 i?ems .
Patrett28802 xl ✓y /Ly jrVO06 G7'
__ _ IDoOL
-- Engineering Group, Inc.
Engineer: . fEZ f:l
751 Sunny Grove Ln. PH: (626) 335-4362
Glendora, CA 91741 FAX: (626) 963-4812 Date: 9 / i l;— Sheet y of
At 4'-0" Depth B := 3.92ft (Wall Height to Critical Point)
(Soil) (Rock Surcharge)
1.6-EFP•B3.1ft 1.2'whorizsurcharge•1ft'B2
Mu + = 2333ft•Ib
6 2
b
b := 12in t := 7in ds := 4in F :— ds2 = 0.016
M 12000in3
u
10001b•ft)
Ku := F 146 p := 0.0043
As := p•b•ds = 0.206•in2
#3 @ 6" o.c. As = 0.22 in2 > 0.206 in2
@ D = 4'-0" t = Tin ds = 4-in #3 @ 6" o.c. Vertical
At 5'-0" Depth B := 4.76ft (Wall Height to Critical Point)
(Soil) (Rock Surcharge)
1.6-EFP•B3.1ft 1.2'whorizsurcharge'1ft•B2
Mu 6 + 2 = 3744ft•lb
b ds2
b := 12in t := 8in ds := 5in F :_ = 0.025
M 12000in3
u
10001b•ft)
Ku 150 p := 0.0044 OQROFESS/Oh
F Q, Jc) S R.O FFR q(F�
2 e a
As := p•b-ds = 0.264•in NO. 32994 f R
* EXP. 6/3012016
#3 @ 4" o.c. As = 0.33 in2 > 0.264 in2 sp
AUK
@D = 5'-0" t = 8•in cis = 5-in #3@4" o.c.
Project: �1CDons�tva �'LS
�A11� Patrett
Engineering Group, Inc.
Engineer:
751 Sunny Grove Ln. PH: (626) 335-4362 �,
Glendora, CA 91741 FAX: (626) 963-4812 Date: / ✓S® Sheet i of
At 6'-0" Depth B := 5.60ft (Wall Height to Critical Point)
(Soil) (Rock Surcharge)
:— 1.6•EFP-B3.1ft 2
Mu + 1.2'whorizsurcharge•1ft•B = 5604ft•Ib
6 2
b ds2
b := 12in t := 9in ds := 6in F :_ = 0.036
12000in 3
Mu
10001b•ft)
Ku := F 156 p := 0.0045
As := p•b-ds = 0.324•in2
#3 @ 4" o.c. As = 0.33 in2 > 0.324 in2
@ D = 6'-0" t = 9-in ds = 6-in #3 @ 4" o.c. Vertical
At 7'-0" Depth B := 6.44ft (Wall Height to Critical Point)
(Soil) (Rock Surcharge)
2
Mu 1.6•EFP-B3.1ft + 1.2'whorizsurcharge'1ft•B 7969ft lb
6 2
b ds2
b := 12in t := 10in ds := Tin F :_ = 0.049
M 12000in 3
u1
K 10001b•ft) = 163 ?ROFESS/-
u F p := 0.0048 e`� P R. O^�9
`4 OJG� FFRp
As := p•b-cl = 0.4•in2 No. 32994
* EXP. 6/30/2016 �
#3 @ 12" o.c. + (2) #4 As = 0.51 in2 > 0.4 in2 sqT
@ D = T-0" t = 10•in ds = 7•in CA!.'.
#3 12" o.c. w/ 2 #4 Between Vertical
Project: tilaDon/4 Z i7.e 4 .
Patrell
Engineering Group, Inc. Pool S
751 Sunny Grove Ln. PH: (626) 335 4362 Engineer: ® AIC4)4I . e4
Glendora, CA 91741 FAX: (626) 963-4812 Date: 91 '�7 Sheet (D of �O
At 8'-0" Depth B := 7.27ft (Wall Height to Critical Point)
(Soil) (Rock Surcharge)
1.6•EFP•B3.1ft 1.2'whorizsurcharge'1ft•B2
Mu 6 + =2 10857ft•lb
b ds2
b := 12in t := 11 in ds := 81n F :_ = 0.064
M 12000in 3
u
10001b•ft
Ku �F = 170 p := 0.005
As := p•b•ds = 0.48•in2
#3 @ 12" o.c. + (2) #4 As = 0.51 in2 > 0.48 in2
@ D = 8'-0" t = 11 -in ds = 8-in
#3 @ 12" O.C. w/ (2) #4 Between Vertical
rO FESS/pN.S R.FFR l!1
b ,
'U No. 32994
�F EXP. 6/30/2016 /,