Loading...
PMT15-02746 City of Menifee Permit No.: PMT16-02746 29714 HAUN RD.GCELA? MENIFEE, CA 92586 Type: Residential Electrical c""." tsmk" MENIFEE Date Issued: 09/18/2016 I PERMIT Site Address: 30059 MUIRLANDS DR, MENIFEE, CA Parcel Number: - 92584 Construction Cost: $6,943.00 Existing Use: Proposed Use: Description of SOLAR TR 30422-3 CAMELLIA Work: 10 MODULES 2.65KW LOT 171 Owner Contractor LENNAR HOMES OF CA LENNAR HOMES OF CALIFORNIA INC 980 MONTECITO DR#302 25 ENTERPRISE '. CORONA, CA 92879 ALISO VIEJO, CA 92656 Applicant Phone:9493498269 JEREMIAH ACAYTURRI License Number: 728102 LENNAR HOMES OF CALIFORNIA INC 25 ENTERPRISE ALISO VIEJO, CA 92656 Fee Description OQtr Amount f$1 [Sd1ar, ResYlent7al er 5 11 Gomrn0oial 1 252:00 i Building Permit Issuance 1 27.00 GREEN FEE SMIP RESIDENTIAL 1 1.00 General Plain Ma hWlen6e FeL-7 Electrical 1 12 8b. $293.60 The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and specifications or from preventing builiding operations being carried on thereunder when in violation of the Building Code or of any other ordinance of City of Menifee. Except as otherwise stated,a permit for construction under which no work is commenced within six months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be forfeited. AA_Bldg_Permit_Template.rpt Page 1 of 1 BUILDING & SAFETY PERMIT/PLAN CHECK APPLICATION 4 ; Menifee DATE 08/25/2015 PERMIT/PLAN CHECK NUMBER TYPE: ❑COMMERCIAL ❑✓ RESIDENTIAL ❑MULTI-FAMILY ❑MOBILE HOME ❑POOL/SPA ❑SIGN SUBTYPE: ❑✓ ADDITION []ALTERATION ❑DEMOLITION ❑ELECTRICAL ❑MECHANICAL ❑NEW ❑PLUMBING [—IRE-ROOF-NUMBER OF SQUARES DESCRIPTION OF WORK Solar Permit- Plan 2077-2.65kW/10 PCS Master Solar Plan Permit No.: PMT14-02630 PROJECT ADDRESS 30059 Muirlands Drive, Menifee, CA 92584 ASSESSOR'S PARCEL NUMBER LOT 171 TRACT 30422-3 PROPERTY OWNER'S NAME Lennar Homes of Californina, Inc. ADDRESS 980 Montecito Dr., Suite 302, Corona, CA 92879 PHONE (951) 817-3680 EMAIL leremiah.acayturri@lennar.com APPLICANT NAME Jeremiah Acayturri ADDRESS 980 Montecito Dr., suite 302, Corona, CA 92879 PHONE (951) 817-3680 EMAIL leremiah.acayturri@lennar.com CONTRACTOR'S NAME Lennar Homes of California, Inc. OWNER BUILDER? ❑✓ YES❑NO BUSINESS NAME Lennar Homes of California, Inc. ADDRESS 980 Montecito Dr., Suite 302, Corona,CA 92879 PHONE (951) 817-3680 EMAIL jeremiah.acayturri@lennar.com CONTRACTOR'S STATE LIC NUMBER 728102 LICENSE CLASSIFICATION A&B VALUATION $ $6,943.00 SO FT L SO FT APPLICANT'S SIGNATURE DATE 08/25/2015 CITY STAFF USE ONLY DEPARTMENT DISTRIBUTION t� �� CITY Of MENIFEE BUSINESS LICENSE NUMBER BUILDING PLANNING ENGINEERING FIRE GREEN ` SMIP INVOICE Y� PAIDAMOUNT AMOUNT '..' CASH -CHECK# CREDIT CARD VISA/MC PLAN CHECK FEES PAIDAMOUNT CASH CHECK# :.=CREDIT CARD VISA/MC OWNER BUILDER VERIFIED (',)YES 0 NO DL NUMBER NOTARIZED LETTER YES NO City of Menifee Building&Safety Department 29714 Haun Rd. Menifee, CA 92586 951-672-6777 www.cityofinenifee.us Inspection Request Line 951-246-6213 SYSTEM INFORMATION BUYER ACKNOWLEDGES THAT THE SOLAR MODULES TO BE INSTALLED ITEM DTY MFR. MODEL ON THE ROOF OF THE HOME WILL BE SUBSTANTIALLY IN THE SYSTEM SIZE 2.65KW I LOCATIONS INDICATED BY THE ILLUSTRATION. MODULE 10 PCS. HYUNDAI I HIS-S265RG(265W) INVERTER 10 PCS. ENPHASE M2)5-60-2LL-S22-IG BUYER:_____ ROOF TYPE I TILE W/COMPOSITE SHINGLE UNDER ARRAY DATE:_ _ <.� i Y OF MENIF SUB-ARRAY INFORMATION ARRAY#1 ARRAY#2 4RRAY#3 �I,iILDI G AND MOD CITY 10 NA NA City of Menifee BUYER. TILT 23" NA I NA Building Dept ------------- --------- PLAN A PROM AZIMUTH 180° NA NA DATE:________- — _ SEP 0 3 [.;;a REVIEWED B Receive:" *Approvalo these plans i aLproval of,any violation regulations ndordinana 10'-10" 1P-7" jobsite until completion. a rz <N ¢Q �o SOLADECK WIRE TRANSITION BOX (UNDER ARRAY) PV AS DISCONNECT EXTERIOR-GARAGE UTILITY METER 8 MAIN SERVICE PANEL (VERIFIED BY BUILDER) NOTE:DIMENSIONS ARE SHOWN IN PLANE OF ROOF PLAN 2077 ELEVATION A-REVERSE z ORIENTATION 4 LOT# 171 CAMELLIA @ THE ENNAR ORIGINAL BY:ANGELA BURKE DATE 15.08.18 r 980 MONTECITO DRIVE,#302 REVIEWED BY:JIMMY METER I DATE:15.08.19 LAKES CORONA,CA 92879 REV.# BY DATE DESCRIPTION Vnornasbc DWG TITLE: PAGE#: SCALE: SITE LOCATION: $01AI INDIVIDUAL 4571 Broadway Street PLOT PLAN /Ib"=1'-D" 30059 MUIRLANDS DRIVE BorI CO 803N SYSTEM LAYOUT MENIFEE CA 303.447.0300 E SAFETY ,L o 86 82 83�� 84 , 85 ® L ndq deCSvs g OS 2W3. --Mal p dq J Pasts a _- L hall not be It of any provis s. This set a I � r 1i72 912°�ad Blw �s - ii assoz I S saaa 173 'R°90- 183 170 92 s . '' I e� plan 3, �J i nWq 2785a � oCaOS 184 169 tea' Fr N PLAN 2077 ELEVATION A-REVERSE ORIENTATION 4 LOT#171 CAMELLIA @ THE LENNAR; ORIGINAL BY: ANGELA BURKE DATE I5.OB.18 980 MONTECITO DRIVE, #302 REVIEWED BY:JIMMY METER DATE 15.08.19 LAKES CORONA.CA 92879 REV.# BY DATE DESCRIPTION Vnarnast;d DWG TITLE: PAGE#: I SCALE: SITE LOCATION: some INDIVIDUAL 4571 Broadway Street PLOT PLAN 2 I/64"=1'-0' 30059 MUIRLANDS DRIVE Boulder,CO 803N SITE PLAN MENIFEE,CA 303.447.0300 MODULE SPECS AND CALCULATIONS INVERTER SPECS AND CALCULATIONS ITEM NOTE/CALC UNIT DETAIL ITEM NOTE/CALC UNIT DETAIL LOCATION MENIFEE,CA INV. MAKE INVERTER SPEC ENPHASE TEMP.AMBIENT HIGH(TMAX) ASHRAE 2% °C 37 INV. MODEL INVERTER SPEC M215-60-2LL-S22-IG TEMP,AMBIENT LOW(THIN) ASHRAE EXTR.MIN °C -2 INV. MAX POWER,(WAC MAX) INVERTER SPEC WATTS(AD) 225 TEMP.MODULE TEST(TTEST) MODULE SPEC °C 25 INV. INPUT V,(VDC MAX) INVERTER SPEC VOLTS(DC) 48 TEMP.DELTA LOW(TOELTA) THIN-TTEST °C -27 INV. OUTPUT V.(VAC NOM) INVERTER SPEC VOLTS(AC) 240 ! DEP MOD. MANUFACTURER MODULE SPEC HYUNDAI INV. OUTPUT FREQUENCY INVERTER SPEC HERTZ 60 MOD. PART NUMBER MODULE SPEC HIS-S265RG INV. OUTPUT CURRENT, IAC INVERTER SPEC AMPS(AC) 0.9 MOD. POWER STC IN MODULE SPEC WATTS(oc) 265 INV. PHASE QUANTITY INVERTER SPEC PHASE I MOD. POWER PTO MODULE SPEC WATTS(DC) 238 1 COMPLIANCE INVERTER SPEC UL1741/IEEE1547 MOD. OPERATING VOLTAGE(VMP) MODULE SPEC VOLTS(DC) 31,30 INV. GROUNDING INVERTER SPEC ISOLATED MOD, OPEN CCT. VOLTAGE(VOC) MODULE SPEC VOLTS(DC) 38.10 INV.CITY, MAX/BRANCH COT. INV.QTYDc OTY 10 MOD. COEFF. VOLT/TEMP(COST) MODULE SPEC V/°C -0.114 BRANCH OCT. OUTPUT, IMAXBC UAC'INVATYDO) AMPS(AC) 9.00 MOD. MAX VOLTAGE(VMAXMOD) (VOc 4(TD`COEF)) VOLTS(DC) 41.18 INV.QUANTITY,TOTAL INV.QTYT DTY 10 f MOD. OPERATING CURRENT(IMP) MODULE SPEC AMPS(DC) 8.50 TOTAL SYSTEM OUTPUT, IMAXTS (IAC-INV.QTYT) I AMPS(AU 1 9.00 MOD. SHORT OCT. CURRENT USA) MODULE SPEC AMPS(DC) 9.00 MOD. MAXIMUM CURRENT(IMAX) (ISC` 1,25) AMPS(DC) 1L25 MIN.AMPACITY REQ'D,PER NEC (IMAX- 1.25) AMPS(DC) 14.06 SERIES FUSE RATING,MAX MODULE SPEC AMPS(DC) 15 AStroed In ELECTRICAL EQUIPMENT SCHEDULE ins of the. KEY QTY MANUFACTURER MODEL NOTES TRADE 10 HYUNDAI HIS-S265RG(265W) PV MODULE SOLAR. �pproyed 2 10 ENPHASE M215-60-2LL-S22-IG PV INVERTER SOLAR 3 1 RSTC/SOLADECK 0786-3R5 PV ROOF JUNCTION BOX,NEMA 3R SOLAR 4 1 CUTLER-HAMMER DG221URB PV AC DISCONNECT,NEMA 3R,240V.30A SOLAR 5 1 ENPHASE ENVOY PV DATA MONITOR, 120V SOLAR 6 1 TBD TBD I20V DEDICATED RECEPTACLE FOR ENVOY PV DATA MONITOR SOLAR 7 1 TBD TBD CATS PORT FOR SOLAR PV INTERNET CONNECTION TO HOME NETWORK BOX SOLAR B NOTE CUTLER-HAMMER TBD PV BRANCH CIRCUIT BREAKERS, I X I5A-IP(ENVOY) SOLAR 9 NOTE CUTLER-HAMMER TBD PV BREAKER, I x 20A-2P,LOCATE AT OPPOSITE END OF BUS FROM MAIN BREAKER SOLAR 10 1 TBD TBD SERVICE PANEL, MIN. 125A BUS I BLOB ELEC. 11 TBD TBD UTILITY METER, IPH, 120/24OV,200A BLDR. ELEC. 12 TBD I TBD I GROUNDING ELECTRODE LIFER 1 BLDR. ELEC. CONDUCTOR SIZING CALCULATIONS INTERCONNECTION CALCULATIONS 1)CONDITION OF USE(COU): (AMPACITY'TEMP. DERATE•FILL DERATE)VG.REQ'D(IMAX) .ITEM UNIT PANEL 2)TERMINALS(TERM): AMPACITY AT TERMINALS.vs. RED D,(IMAX°1,25) PANEL MFR. CUTLER-HAMMER KEY SIZE CU/AL INSULATION CALC. AMPACITY W/O TEMP, FILL RESULT REO'D OCD BUS RATING AMPS 200 TYPE. DERATES DERATE DERATE (A) (A) USED(A) MAIN DISCONNECT AMPS 200 A #12 CU THWN-2 COU 30 76 1.0 22.80 1 9.00 ALLOWED PV PER NEC AMPS 40 TERM 25 25 11.25 20 PV OCPD DEVICE USED AMPS. 20 B #10 CU NM-B COU 40 .91 1.0 36.40 1 9.00 TERM 35 35 11.25 20 C #10 CU NM-B COU 40 .91 1.0 36.40 9.00 TERM 35 35 11.25 20 CONDUCTOR SCHEDULE KEY CONDUCTORS CU/AL TYPE LOCATION I TRADE A 1412 ENGAGE CABLE,1-#6G,FREE AIR CU TC-ER ARRAY SOLAR B 3-#10, 1-#10 EGC CU NMI(ROMEX) INTERIOR SOLAR C 3-#10, I410 EGG CU NMI(ROMEX) INTERIOR SOLAR D CAT5E.ETHERNET CABL I CU 1 CAT5E INTERIOR SOLAR 11 © 05 D _-O ® o • 7O e SEE 0 NOTE 15 ISAiw mAO9 C ity 2 OI D 3 M A 12= I I I 1 EXTERIOR-GARAGE I ROOF ELECTRICAL DIAGRAM 2.65KW LOT# 171 CAMELLIA @ THE LENNAR: ORIGINAL BY: ANGELA BURKE DATE:I5.013.18 980 MONTECITO DRIVE,#302 REVIEWED BY:JIMMY METER DATE:15.08.19 LAKES CORONA,CA 92679 REV.# BY DATE I DESCRIPTION namast;e DWG TITLE: PAGE#: SCALE: $91Av SITE LOCATION: 4571 Braadway SVeet INDIVIDUAL 30059 MUIRLANDS DRIVE OOUtler,GO W304 PLOT PLAN 3 NTS MENIFEE,CA 303447 W00 ELECTRICAL STRUCTURAL NOTES: SOLAR CONTRACTOR- 1)ALL PV ROOF ATTACHMENTS WILL BE SPACED ALONG MODULE RACKING RAILS AT NOT GREATER THAN 48"O.C. 2)ALL PV ROOF ATTACHMENTS WILL BE STAGGERED BY ROW AMONGST THE ROOF FRAMING MEMBERS,TO MAXIMUM EXTENT POSSIBLE. 3)ROOF PENETRATIONS ASSOCIATED WITH SOLAR RACKING WILL BE SEALED WITH AN APPROVED SEALANT. MENT 4)SOLADECK WIRE TRANSITION BOX WILL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS. IT WILL BE FLASHED AND SEALED. 5)PV ARRAY WILL BE A MINIMUM OF 3"ABOVE THE COMPOSITE SHINGLE ROOF SURFACE. 6)THE UNIRAC SOLARMOUNT RACKING SYSTEM AND SOLAR PV ARRAY WILL BE INSTALLED ACCORDING TO THE UNIRAC SOLARMOUNT CODE-COMPLIANT INSTALLATION MANUAL.VERSION 227.3,PUB IA0113-ICC,JANUARY 2014. 7)UNIRAC TOP CLAMPS REQUIRE A ONE INCH NC)SPACE BETWEEN PV MODULES. SOLARMOUNT RAILS MUST EXTEND A MINIMUM OF TWO INCHES 0?) BEYOND THE EDGE OF 8) THE ARRAY/SUB-ARRAY. 8) / UNIRAC SOLARMOUNT REQUIRES THAT A THERMAL EXPANSION GAP BE INSTALLED FOR ANY RAIL LENGTH OF GREATER THAN 40. ROOFING CONTRACTOR- R D DISTANCE BETWEEN ARRAY EDGE AND TRANSITION FLASHING(COMPOSITION TO TILE)WILL BE A MINIMUM OF 3". 2)26 GAUGE INTERLOCKING FLASHING"SIDEWALL"TO BE INSTALLED ALONG THE LENGTH OF THE PV ARRAY AT ROOFING MATERIAL TRANSITION. IT SHALL BE APROVED PRIOR TO PV SYSTEM INSTALLATION. 3)PEEL-N-STICK BASE TO BE INSTALLED ONE FOOT(I')OR MORE BEYOND THE EDGE OF THE COMPOSITION SHINGLE,DOWN TO THE ROOF EAVE. PEEL-N-STICK BASE TO BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS. 4)AREAS UNDER EACH PV ARRAY SHALL BE ROOFED WITH COMPOSITION SHINGLE. COMPOSITION SHINGLE SHALL RUN FROM ABOVE THE PV ARRAY TO THE ROOF EAVE. L_ 5)TILE INSTALLED BELOW THE ARRAY TO BE INSTALLED ABOVE THE COMPOSITION ROOF PER ROOFER SPECIFICATIONS. a permltfor 6)BIRDSTOP WILL BE INSTALLED AT THE UPPERMOST TRANSITION FROM TILE TO COMPOSITION SHINGLE. BIRDSTOP TO BE SPECIFIED BY ROOFER PRIOR TO INSTALLATION. eral/state 01 ins must be k ELECTRICAL NOTES: GENERAL - U ALL PV EQUIPMENT WILL BE TESTED AND LISTED FOR ITS USE BY A NATIONALLY RECOGNIZED TESTING LABORATORY(NI 2)THE GROUNDING OF THE PHOTOVOLTAIC SYSTEM SHALL COMPLY WITH THE APPLICABLE VERSION OF THE NEC/CEC. 3)ALL GROUNDING ELECTRODE CONDUCTORS WILL BE INSTALLED IN A CONTINUOUS LENGTH EXCEPT WHERE SPLICED BY AN IRREVERSIBLE CONNECTOR OR EXOTHERMIC WELD. 4)NON-CURRENT CARRYING METAL PARTS SHALL BE CHECKED FOR PROPER GROUNDING,NOTING THAT TERMINAL LUGS BOLTED ON AN ENCLOSURE'S FINISHED SURFACE MAY BE ELECTRICALLY INSULATED BECAUSE OF PAINT/FINISH. PAINT/FINISH AT POINT OF CONTACT SHALL BE PROPERLY REMOVED. 5)ROOF PENETRATIONS WILL BE COMPLETED AND SEALED PER APPLICABLE CODE. 6)ALL CONDUCTORS WILL HAVE A 90-C RATING TO ENSURE CODE COMPLIANCE. SOLAR.CONTRACTOR.- 7)MODULE CERTIFICATIONS WILL INCLUDE UL1703,IEC6A46, IEC61730. 8)CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS, 9)RACEWAY POINT OF PENETRATION FROM EXTERIOR TO INTERIOR WILL BE SEALED TO PREVENT INGRESS OF WATER AND INSECTS. 10)DC WIRING IS LIMITED TO PV ARRAY FOOTPRINT W/ENPHASE MICRO-INVERTER SYSTEM. ID MODULE AND ENPHASE WIRING SHALL BE LOCATED AND SECURED UNDER THE ARRAY USING SUITABLE WIRING CLIPS. WIRING SHALL NOT MAKE CONTACT WITH THE ROOF SURFACE AND SHALL BE MANAGED IN A WORKMAN-LIKE MANNER. 12)EQUIPMENT GROUNDING CONDUCTORS WILL BE SIZED IN ACCORDANCE WITH NEC TABLE 250.122. 13)CONDUCTOR TERMINATIONS WILL BE TORQUED PER DEVICE LISTING,OR MANUFACTURER'S RECOMMENDATIONS. 14)A PV AGGREGATION PANEL(SUB PANEL)WILL NOT BE INCLUDED FOR SYSTEMS WITH ONE BRANCH CIRCUIT. 15)A DEDICATED 120V BRANCH CIRCUIT IS REQUIRED IN MASTER CLOSET(OR EQUIVALENT)FOR ENPHASE ENVOY MONITOR, 16)THE INTERCONNECTION BREAKER SHALL BE LOCATED AT THE OPPOSITE END OF THE BUSBAR FORM THE MAIN OCPD. SIGNAGE- 17)PV SYSTEMS SHALL BE CLEARLY MARKED IN ACCORDANCE WITH NEC ARTICLE 690 AND OTHER APPLICABLE STATE AND LOCAL CODES. 18)ALL SAFETY MARKING/PLACARDS SHALL BE PERMANENTLY ATTACHED BY ADHESIVE OR OTHER MECHANICAL MEANS. 19)MARKING/PLACARDS WILL BE METAL OR PLASTIC WITH ENGRAVED OR MACHINE PRINTED LETTERING. BACKGROUND WILL BE RED WITH WHITE CAPITAL LETTERING OF MINIMUM HEIGHT J'. 20)ALL WIRING/RACEWAYS/JUNCTION BOXES WILL BE MARKED'PHOTOVOLTAIC POWER SOURCE,'OR EQUIVALENT;WIRING/RACEWAYS SHALL BE MARKED EVERY 10'. BUILDER ELECTRICAL AND SOLAR CONTRACTORS- 21)INSTALLATION SHALL BE COMPLETED IN A NEAT AND WORKMAN-LIKE MANNER. 22)SPACE REQUIREMENTS FOR ALL ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110:26. CAMELLIA @ THE LENNAR: ORIGINAL BY: ANGELA BURKE DATE:15.08.18 980 MONTECITO DRIVE,#302 REVIEWED BY:JIMMY METER DATE 15.08.19 LAKES CORONA,CA 92879 REV.# BY DATE DESCRIPTION namasb6 DWG TITLE: PAGE# SCALE: ague SITE LOCATION: 4571 Broadway Street INDIVIDUAL 30059 MUIRLANDS DRIVE BO .r. 0304 PLOT PLAN 4 NIPS MENIFEE 303,4 CO3 CA 303.44].0300 NOTES CAUTION: POWER TO THIS BUILDING IS SUPPLIED BY THE UTILITY AND A SOLAR PV SYSTEM. DISCONNECTS ARE LOCATED AS SHOWN. DATE Ir an ty ut on the SOLADECK WIRE TRANSITION BOX (UNDER ARRAY) PV AC DISCONNECT EXTERIOR-GARAGE UTILITY METER& MAIN SERVICE PANEL (VERIFIED BY BUILDER) SERVICE BY QUALIFIED PERSONNEL ONLY CONTACT: SUNSTREET ENERGY GROUP 1-877-SLR-POWR NOTE: SEE MASTER SET FOR ADDITIONAL PLACARD INFORMATION CAMELLIA @ THE LENNARI ORIGINAL BY ANGELA BURKE I DATE:15.00.18 9BO MONTECITO DRIVE,#502 REVIEWED BY:JIMMY METER DATE:15.DB.19 LAKES CORONA,CA 92879 REV.* BY DATE DESCRIPTION namas A. OWG TITLE: PAGE#: SCALE: SITE LOCATION: sour treet INDIVIDUAL 4571&o,COcWay 304 PLOT PLAN 5 NTS 30059 MUIRLANDS DRIVE Boulder,C0 B0304 PLACARDS MENIFEE,CA 303A47.0300