Loading...
PMT15-02743 City of Menifee Permit No.: PMT15-02743 29714 HAUN RD. Type: Residential Electrical 'ACCI1.J��. MENIFEE, CA 92586 ; 4wma,.,u Calaween MENIFEE Date Issued: 0911812015 1 PERMIT Site Address: 29652 GLENNEYRE WAY, MENIFEE, CA Parcel Number: 92584 Construction Cost: $7,650.40 Existing Use: Proposed Use: Description of SOLAR TR 30422-3 CAMELLIA Work: 11 MODULES 2.92 KW LOT 82 Owner Contractor LENNAR HOMES OF CA LENNAR HOMES OF CALIFORNIA INC , 980 MONTECITO DR#302 25 ENTERPRISE CORONA, CA 92879 ALISO VIEJO, CA 92656 Applicant Phone: 9493498269 JEREMIAH ACAYTURRI License Number: 728102 LENNAR HOMES OF CALIFORNIA INC 25 ENTERPRISE ALISO VIEJO, CA 92656 Fee Description Qtv Amount is Sotal' Rosi Dan alar St tali COW6ercral 1 25 .40 Building Permit Issuance 1 27.00 GREEN FEE':_ ir_ 1,6D SMIP RESIDENTIAL 1 1.00 General Pisa Mainte ancFee-Electrical 1 12,6(1 $293.60 The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and specifications or from preventing builiding operations being carried on thereunder when in violation of the Building Code or of any other ordinance of City of Menifee. Except as otherwise stated,a permit for construction under which no work is commenced within six months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be forfeited. AA_Bleg Permit Template.rpt Page 1 of 1 BUILDING & SAFETY PERMIT/PLAN CHECK APPLICATION Agldz.i ?4S. 'f Menifee DATE 08/25/2015 PERMIT/PLAN CHECK NUMBER TYPE: ❑COMMERCIAL ❑✓ RESIDENTIAL ❑MULTI-FAMILY ❑MOBILEHOME ❑POOL/SPA ❑SIGN SUBTYPE: ❑✓ ADDITION ❑ALTERATION [—]DEMOLITION ❑ELECTRICAL ❑MECHANICAL ❑NEW ❑PLUMBING ORE-ROOF-NUMBEROFSQUARES DESCRIPTION OF WORK Solar Permit- Plan 2399-2.92kW/ 11 PCS Master Solar Plan Permit No.: PMT14-02630 PROJECT ADDRESS 29652 Glenneyre Way, Menifee, CA 92584 ASSESSOR'S PARCEL NUMBER LOT S2 TRACT 30422-3 PROPERTY OWNER'S NAME Lennar Homes of Californina, Inc. ADDRESS 980 Montecito Dr., Suite 302, Corona, CA 92879 PHONE (951) 817-3680 EMAIL jeremiah.acayturri@lennar.com APPLICANT NAME Jeremiah Acayturri ADDRESS 980 Montecito Dr., suite 302, Corona, CA 92879 PHONE (951) 817-3680 EMAIL jeremiah.acayturri@lennar.com CONTRACTOR'S NAME Lennar Homes of California, Inc. OWNER BUILDER? R YES❑NO BUSINESS NAME Lennar Homes of California, Inc. ADDRESS 980 Montecito Dr., Suite 302, Corona, CA 92879 PHONE (951) 817-3680 EMAIL jeremiah.acayturri@lennar.com CONTRACTOR'S STATE LIC NUMBER 728102 LICENSE CLASSIFICATION A&B VALUATION$ $ 7,650.40 SO FT L SQ FT APPLICANT'S SIGNATURE DATE 08/25/2015 CITYSTAFF USE ONLY DEPARTMENT DISTRIBUTION CITY OF MENIFEE BUSINESS LICENSE NUMBER BUILDING PLANNING ENGINEERING FIRE GREEN I� SMIP INVOICE /n pAID AMOUNT AMOUNT �1 0CASH CHECK It CREDFFCARD VISA/MC PLAN CHECK FEES PAID AMOUNT ? CASH !>CHECK# OCREDITCARD VISA/MC OWNER BUILDER VERIFIED ".)YES NO DLNUMBER NOTARIZED LETTER 7 YES ":) NO City of Menifee Building&Safety Department 29714 Haun Rd. Menifee, CA 92586 951-672-6777 www.citycfinenifee.us Inspection Request Line 951-246-6213 SYSTEM INFORMATION BUYER ACKNOWLEDGES THAT THE SOLAR MODULES TO BE INSTALLED ITEM OTY MEN. MODEL ON THE ROOF OF THE HOME WILL BE SUBSTANTIALLY IN THE SYSTEM SIZE 2.92RW I LOCATIONS INDICATED BY THE ILLUSTRATION. ;��! C MODULE II PCS. HYUNDAI HIS-S265RG(265W7 BUYER:—____ _ 'r IVII irL INVERTER II PCS. ENPHASE M215-60-2LL-S22-IG _____________—_______—_____ ROOF TYPE TILE W/COMPOSITE SHINGLE UNDER ARRAY DATE: _/A TIN D [ FETY C SUB-ARRAY INFORMATION C 7718 TCfY `7 IL r I {u ARRAY#1 ARRAY #2 ARRAY#3 ,._dtS APPROVAL p MOD OTY 4 7 NA it --- TILT 23^ 23- NA City of enifee AZIMUTH 90° 90' NA Buildin TE_____-----------------___ RE' IEWED $ 4 SEPU32; Re C e A v c r~ 'r o.a1 of these plans shall iot be constr N of,any violation of at y provislons I 1 I�ni ,runs and ordinances. T iis set of appr jBu w until completion. 3' 5'-5- 5'-5' P t >Z K N QQ U Z y I m KJ QLL PV AC DISCONNECT EXTERIOR-GARAGE UTILITY METER IN MAIN SERVICE PANEL (VERIFIED BY BUILDER) STRA ECKTRANSITION WIRE TRANSITION BOX (UNDER ARRAY) NOTE:DIMENSIONS ARE SHOWN IN PLANE OF ROOF ^' `v PLAN 2399 ELEVATION A-REVERSE IV O ORIENTATION I LOT#82 ® t LEHMAN ORIGINAL BY: ANGELA BURKE DATE:15.08.18 CAMELLIA @THE 980 MONTECITO DRIVE,#302 REVIEWED BY:JIMMY METER DATE:15.08.19 LAKES CORONA,CA 92879 REV.# BY DATE DESCRIPTION 4W narrI DWG TITLE: PAGE#: SCALE: SITE LOCATION: aoi�e INDIVIDUAL 4571 BroeI Street PLOT PLAN 1/16"-1'-0' 29652 GLENNEYRE WAY Boulder,CO 60304 SYSTEM LAYOUT MENIFEE,CA 303.447.030D IPA aed to' t )f the fei 84 85 . ovedpN _ qitYe° ` oPBCS I� 11 SPlao - ISl9M ''°" _.. 173"__ 172 91 °99oZ 174 a �°:175 I , 182� ® 183 , �9 Nan® i ge1.1 206jq 17092 °LeOSaos $w r 184 ' 169 N PLAN 2399 ELEVATION A-REVERSE ORIENTATION I LOT#82 CAMELLIA @ THE LENNAR: ORIGINAL BY: ANGELA BURKE I DATE:15.08.18 950 MONTECITO DRIVE,#502 REVIEWED BY:JIMMY METER DATE:15.08.19 LAKES CORONA,CA 92879 REV.# BY DATE DESCRIPTION Vnamast;6 DWG TITLE: PAGE#: SCALE: SITE LOCATION: sou. INDIVIDUAL 4571 Broadway Street PLOT PLAN 2 I/64"=V-W 29652 GLENNEYRE WAY Boulder,CO 80304 SITE PLAN MENIFEE,CA 303.4470300 MODULE SPECS AND CALCULATIONS INVERTER SPECS AND CALCULATIONS ITEM NOTE/GALL UNIT I DETAIL ITEM NOTE/CALC I UNIT DETAIL LOCATION MENIFEE,CA INV. MAKE INVERTER SPEC ENPHASE TEMP,AMBIENT HIGH(TMAX) ASHRAE 2% °C 37 INV. MODEL INVERTER SPEC M215-60-2LL-S22-IG TEMP,AMBIENT LOW(TMIN) ASHRAE EXTR.MIN °C -2 ITV. MAX POWER(WAC MAX) INVERTER SPEC WATTS(AC) 225 TEMP.MODULE TEST(TTEST) MODULE SPEC °C 25 INV. INPUT V.(VUC MAX) INVERTER SPEC VOLTS(DO 48 TEMP.DELTA LOW(TOELTA) TRIM-TTEST °C -27 INV.OUTPUT V.(VAc MOM) INVERTER SPEC VOLTS(AO 24D RTME MOD. MANUFACTURER MODULE SPEC HYUNDAI INV. OUTPUT FREQUENCY INVERTER SPEC HERTZ 60 MOD. PART NUMBER MODULE SPEC HIS-S265RG INV. OUTPUT CURRENT,IAC INVERTER SPEC AMPS(AG) 0.9 MOD. POWER STC IN MODULE SPEC WATTS(DO 265 INV. PHASE QUANTITY INVERTER SPEC PHASE I MOD.POWER PTC MODULE SPEC WATTS(DO 23B COMPLIANCE INVERTER SPEC UL1741/IEEE1547 MOO OPERATING VOLTAGE WHO MODULE SPEC VOLTS WC) 31.30 INV. GROUNDING INVERTER SPEC ISOLATED MOD.OPEN CCT. VOLTAGE(Voc) MODULE SPEC VOLTS(DO 38.10 INV. OTY, MAX/BRANCH CCT. INV.QTYBC QTY II 1� MOD.COEFF. VOLT/TEMP(COEF) MODULE SPEC V/°C -0,114 BRANCH CCT. OUTPUT, IMAXBC (IAC•INV,QTYBC) AMPS OCS 9.90 •_•yI MOD. MAX VOLTAGE(VMAXMDD) (VOC a (TD'COEF)) VOLTS(DO 41.18 INV. QUANTITY.TOTAL INV.QTYT QTY II MOD.OPERATING CURRENT(IMP) MODULE SPEC AMPS 5, 8,50 TOTAL SYSTEM OUTPUT, IMAXTS (111•INV,QTYT) AMPS(AO 9.90 MOD.SHORT CCT. CURRENT(ISO MODULE SPEC AMPS(DO) 9.00 MOD. MAXIMUM CURRENT(TMAX) (ISC° 1.25) AMPS(DC) 11.25 MIN.AMPACITY REQ'D,PER NEC (IMAX-L25) AMPS(DC) 14.06 SERIES FUSE RATING,MAX MODULE SPEC AMPS(DC) 15 .'a permk. ELECTRICAL EQUIPMENT SCHEDULE IeCd�ESf .KEY OTY MANUFACTURER MODEL NOTES TRADE ``'. 1 11 HYUNDAI MC-S265RG(265W) PV MODULE SOLAR a N 5 mug 2 II ENPHASE M215-60-2LL-S22-I6 PV INVERTER SOLAR 3 2 RSTC/SOLADECK 07B6-3R5 PV ROOF JUNCTION BOX,NEMA 3R SOLAR t I CUTLER-HAMMER DG221URB PV AC DISCONNECT,NEMA SIR 240V,30A SOLAR 5 1 ENPHASE ENVOY PV DATA MONITOR, 126V SOLAR 6 1 LED TBD 120V DEDICATED RECEPTACLE FOR ENVOY PV DATA MONITOR SOLAR 7 1 LED TBD CAT5 PORT FOR SOLAR PV INTERNET CONNECTION TO HOME NETWORK BOX SOLAR B NOTE CUTLER-HAMMER TBD PV BRANCH CIRCUIT BREAKERS; I X 15A-IP(ENVOY) SOLAR 9 NOTE CUTLER-HAMMER TBD PV BREAKER, I x 2GA-2P,LOCATE AT OPPOSITE END OF BUS FROM MAIN BREAKER SOLAR 10 1 TBD TBD SERVICE PANEL, MIN. 125A BUS BLDR. ELEC. 11 TBD TBD UTILITY METER, 1PH. 120/240V,200A BLDR. ELEC. 12 TBD TBD GROUNDING ELECTRODE UFER BLDR ELEC. CONDUCTOR SIZING CALCULATIONS INTERCONNECTION CALCULATIONS B CONDITION OF USE(CDU): (AMPACITY•TEMP.BERATE'FILL DERATE)VS. REO'D(IMAX) ITEM UNIT I PANEL 2)TERMINALS(TERM): AMPACITY AT TERMINALS.VS. REQ'D,(IMAX• 1.25) PANEL MFR. CUTLER-HAMMER KEY SIZE CU/AL INSULATION CALL. AMPACITY W/0 TEMP. FILL RESULT REO'D OCD BUS RATING AMPS 200 TYPE BERATES DERATE DERATE (A) (A) USED(A) MAIN DISCONNECT AMPS 200 A #12 CU THWN-2 COU 30 M22.80 9.90 ALLOWED PV PER NEC AMPSTERM 251220PV OCPD DEVICE USED AMPS 20B #10 CU NM-B CON LO 40TERM 3535 1238 20 C #10 CU NM-B COU 40 36.40 9.90TERM 3535 I2.38 20 CONDUCTOR SCHEDULE KEY CONDUCTORS I CU7AL I TYPE LOCATION TRADE A 1412 ENGAGE CABLE,146G,FREE AIR I CU I TC-ER ARRAY I SOLAR B 3-#10, -#S EGC I CU I NM-B(ROMEX) I INTERIOR I SOLAR C 3-400,1-#10 EGC I CU I NM-B(ROMEX) INTERIOR I SOLAR 0 CAT5E,ETHERNET CABLE I CU I CAT5E INTERIOR I SOLAR 11 © 5 D O ® o • 7 SEE 10 NOTE I5 2 O ® O B O A AIIP C � G 9 zDOP ! G 2 — I I I 1 EXTERIOR-GARAGE 1 ROOF ELECTRICAL DIAGRAM 2.92KW LOT#82 CAMELLIA @ THE LERMAR ORIGINAL BY: ANGELA BURKE I DATE:15.OB.IB 980 MONTECITO DRIVE,#302 REVIEWED BY:JIMMY METER I DATE:15.08.19 LAKES CORONA,CA 92879 REV.# BY DATE I DESCRIPTION Vnamcisrd DWG TITLE: PAGE#: I SCALE: SITE LOCATION: sOUK INDIVIDUAL 4571 B eed ay Street PLOT PLAN 3 NTS 29652 GLENNEYRE WAY Boulder,CO 80304 MENIFEE,CA 303.447.0300 ELECTRICAL STRUCTURAL NOTES: SOLAR CONTRACTOR- S ALL PV ROOF ATTACHMENTS WILL BE SPACED ALONG MODULE RACKING RAILS AT NOT GREATER THAN 48"OIC. 2)ALL PV ROOF ATTACHMENTS WILL BE STAGGERED BY ROW AMONGST THE ROOF FRAMING MEMBERS,TO MAXIMUM EXTENT POSSIBLE. 3)ROOF PENETRATIONS ASSOCIATED WITH SOLAR RACKING WILL BE SEALED WITH AN APPROVED SEALANT. 4)SOLADECK WIRE TRANSITION BOX WILL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS. IT WILL BE FLASHED AND SEALED. �� 5)PV ARRAY WILL BE A MINIMUM OF 3"ABOVE THE COMPOSITE SHINGLE ROOF SURFACE. 6)THE UNIRAC SOLARMOUNT RACKING SYSTEM AND SOLAR PV ARRAY WILL BE INSTALLED ACCORDING TO THE UNIRAC SOLARMOUNT CODE-COMPLIANT INSTALLATION MANUAL,VERSION 227.3, PUB 140II3-ICC,JANUARY 2014. 7)UNIRAC TOP CLAMPS REQUIRE A ONE INCH(1")SPACE BETWEEN PV MODULES.SOLARMOUNT RAILS MUST EXTEND A MINIMUM OF TWO INCHES(2")BEYOND THE EDGE OF THE PV ARRAY/SUB-ARRAY. B)UNIRAC SOLARMOUNT REQUIRES THAT A THERMAL EXPANSION GAP BE INSTALLED FOR ANY RAIL LENGTH OF GREATER THAN 40. ROOFING CONTRACTOR- D DISTANCE BETWEEN ARRAY EDGE AND TRANSITION FLASHING(COMPOSITION TO TILE)WILL BE A MINIMUM OF 3". � � 2)26 GAUGE INTERLOCKING FLASHING"SIDEWALL"TO BE INSTALLED ALONG THE LENGTH OF THE PV ARRAY AT ROOFING MATERIAL TRANSITION. IT SHALL BE APROVED PRIOR TO PV SYSTEM INSTALLATION. D� 3)PEEL-N-STICK BASE TO BE INSTALLED ONE FOOT(19 OR MORE BEYOND THE EDGE OF THE COMPOSITION SHINGLE,DOWN TO THE ROOF EAVE. PEEL-N-STICK BASE TO BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS. 4)AREAS UNDER.EACH PV ARRAY SHALL BE ROOFED WITH COMPOSITION SHINGLE. COMPOSITION SHINGLE SHALL RUN FROM ABOVE THE PV ARRAY TO THE ROOF EAVE. t_ 5)TILE INSTALLED BELOW THE ARRAY TO BE INSTALLED ABOVE THE COMPOSITION ROOF PER ROOFER SPECIFICATIONS. for,or a( 6)BIRDSTOP WILL BE INSTALLED AT THE UPPERMOST TRANSITION FROM TILE TO COMPOSITION SHINGLE. BIRDSTOP TO BE SPECIFIED BY ROOFER PRIOR TO INSTALLATION, Or City kept or ELECTRICAL NOTES: GENERAL- D ALL PV EQUIPMENT WILL BE TESTED AND LISTED FOR ITS USE BY A NATIONALLY RECOGNIZED TESTING LABORATORY(NI 2)THE GROUNDING OF THE PHOTOVOLTAIC SYSTEM SHALL COMPLY WITH THE APPLICABLE VERSION OF THE NEC/CEC. 3)ALL GROUNDING ELECTRODE CONDUCTORS WILL BE INSTALLED IN A CONTINUOUS LENGTH EXCEPT WHERE SPLICED BY AN IRREVERSIBLE CONNECTOR OR EXOTHERMIC WELD. 4)NON-CURRENT CARRYING METAL PARTS SHALL BE CHECKED FOR PROPER GROUNDING,NOTING THAT TERMINAL LUGS BOLTED ON AN ENCLOSURE'S FINISHED SURFACE MAY BE ELECTRICALLY INSULATED BECAUSE OF PAINT/FINISH. PAINT/FINISH AT POINT OF CONTACT SHALL BE PROPERLY REMOVED. 5)ROOF PENETRATIONS WILL BE COMPLETED AND SEALED PER APPLICABLE CODE. 6)ALL CONDUCTORS WILL HAVE A 90°C RATING TO ENSURE CODE COMPLIANCE. SOLAR CONTRACTOR- 7)MODULE CERTIFICATIONS WILL INCLUDE UL1703, IEC61646, IEC6173D. 8)CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS, 9)RACEWAY POINT OF PENETRATION FROM EXTERIOR TO INTERIOR WILL BE SEALED TO PREVENT INGRESS OF WATER AND INSECTS. 10)DC WIRING IS LIMITED TO PV ARRAY FOOTPRINT W/ENPHASE MICRO-INVERTER SYSTEM. ID MODULE AND ENPHASE WIRING SHALL BE LOCATED AND SECURED UNDER THE ARRAY USING SUITABLE WIRING CLIPS. WIRING SHALL NOT MAKE CONTACT WITH THE ROOF SURFACE AND SHALL BE MANAGED IN A WORKMAN-LIKE MANNER. 12)EQUIPMENT GROUNDING CONDUCTORS WILL BE SIZED IN ACCORDANCE WITH NEC TABLE 250.122. 13)CONDUCTOR TERMINATIONS WILL BE TORQUED PER DEVICE LISTING,OR MANUFACTURER'S RECOMMENDATIONS. 14)A PV AGGREGATION PANEL(SUB PANEL)WILL NOT BE INCLUDED FOR SYSTEMS WITH ONE BRANCH CIRCUIT. 15)A DEDICATED 120V BRANCH CIRCUIT IS REQUIRED IN MASTER CLOSET(OR EQUIVALENT)FOR ENPHASE ENVOY MONITOR. 16)THE INTERCONNECTION BREAKER SHALL BE LOCATED AT THE OPPOSITE END OF THE BUSBAR FORM THE MAIN.GEER. SIGNAGE- 17)PV SYSTEMS SHALL BE CLEARLY MARKED IN ACCORDANCE WITH NEC.ARTICLE 690 AND OTHER APPLICABLE STATE AND LOCAL CODES. 18)ALL SAFETY MARKING /PLACARDS SHALL BE PERMANENTLY ATTACHED BY ADHESIVE OR OTHER MECHANICAL MEANS. 19)MARKING/PLACARDS WILL BE METAL OR PLASTIC WITH ENGRAVED OR MACHINE PRINTED LETTERING. BACKGROUND WILL BE RED WITH WHITE CAPITAL LETTERING OF MINIMUM HEIGHT g` 20)ALL WIRING/RACEWAYS/JUNCTION BOXES WILL BE MARKED"PHDTOVOLTAIC POWER SOURCE,"OR EQUIVALENT;WIRING/RACEWAYS SHALL BE MARKED EVERY 10% BUILDER ELECTRICAL AND SOLAR CONTRACTORS- 21)INSTALLATION SHALL BE COMPLETED IN A NEAT AND WORKMAN-LIKE MANNER. 22)SPACE REQUIREMENTS FOR ALL ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE IIO.Z6. CAMELLIA @ THE LENNAR ORIGINAL BY: ANGELA BURKE DATE:15.00.18 9BO MONTECITO DRIVE#302 REVIEWED BY:JIMMY METER I DATE:15.08.19 LAKES CORONA,CA 92879 REV.# BY DATE DESCRIPTION namaste DWG TITLE: PAGE#: SCALE: SITE LOCATION: udet INDIVIDUAL 4Bo Broadway 3N PLOT PLAN 4 NTS 29662 E,CA YRE WAY Boulder, 7080304 MENIFEE,CA 303.447.0300 NOTES CAUTION: POWER TO THIS BUILDING IS SUPPLIED BY THE UTILITY AND A SOLAR PV SYSTEM. DISCONNECTS ARE LOCATED AS SHOWN. TE the PV AC DISCONNECT EXTERIOR-GARAGE UTILITY METER e MAIN SERVICE PANEL (VERIFIED BY BUILDER) SOLADECK WIRE TRANSITION BOX (UNDER ARRAY) SERVICE BY QUALIFIED PERSONNEL ONLY CONTACT: SUNSTREET ENERGY GROUP 1-877-SLR-POWR NOTE: SEE MASTER SET FOR ADDITIONAL PLACARD INFORMATION CAMELLIA @ THE LENNAR: ORIGINAL BY: ANGELA BURKE I DATE'.15.08.18 980 MONTECITO DRIVE,9302 REVIEWED BY:JIMMY METER I DATET5.08.19 LAKES CORONA,CA 92879 REV.# BY DATE DESCRIPTION namast6 DWG TITLE: PAGE#: SCALE: Street SITE LOCATION: INDIVIDUAL 4Bo Ber,CO 8Street PLOT PLAN 5 NITS 29052 GLENNEVRE WAY Boulder,C080304 MENIFEE,CA 303.44Z0300 PLACARDS