Loading...
PMT15-02228 1 City of Menifee Permit No.: PMTIS-02228 29714 HAUN RD. "CACC!l MENIFEE, CA 92586 Type: Residential Electrical MENIFEE Date Issued: 0 8/1 912 0 1 5 I PERMIT Site Address: 29617 ASHTON CT, MENIFEE, CA 92584 Parcel Number: Construction Cost: $7,650.40 Existing Use: Proposed Use: Description of SOLAR TR 30422-3.CAMELLIA Work: 187 MODULES 2.92KW LOT 187 Owner Contractor LENNAR HOMES OF CA LENNAR HOMES OF CALIFORNIA INC 980 MONTECITO DR#302 25 ENTERPRISE CORONA, CA 92879 ALISO VIEJO, CA 92656 Applicant Phone: 9493498269 JEREMIAH ACAYTURRI License Number: 728102 LENNAR HOMES OF CALIFORNIA INC 25 ENTERPRISE ALISO VIEJO, CA 92656 Fee Description gyt Amount l$1 S01ar,Rgsitl0ttt al or,:Bmall C6p metclal is 2�2 QQ'I Building Permit Issuance 1 27.00 GREEN FEE 1, 4 OO,J SMIP RESIDENTIAL 1 1.00 $281.00 The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and specifications or from preventing builiding operations being carried on thereunder when in violation of the Building Code or of any other ordinance of City of Menifee.Except as otherwise stated,a permit for construction under which no work is commenced within six months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be forfeited. AA_Bldg_Permit_Template.rpt Page 1 of 1 PERMIT/PLANBUILDING & SAFETY • • • r 'Menifee DATE 07/30/2015 PERMIT/PLAN CHECK NUMBER OO b TYPE: [—]COMMERCIAL ❑✓ RESIDENTIAL ❑MULTI-FAMILY ❑MOBILEHOME ❑POOL/SPA []SIGN SUBTYPE: ❑✓ ADDITION ❑ALTERATION ❑DEMOLITION ❑ELECTRICAL ❑MECHANICAL ❑NEW ❑PLUMBING El RE-ROOF-NUMBER OF SQUARES DESCRIPTION OF WORK Solar Permit-Plan 2399-2.92 kW/ 11 PCS Master Solar Plan Permit Number: PMT14-02630 PROJECT ADDRESS 29617 Ashton Ct Menifee, CA 92584 ASSESSOR'S PARCEL NUMBER LOT 187 TRACT 30422-3 OWNER NAME Lennar Homes of California, Inc. ADDRESS 980 Montecito Dr., Suite 302 Corona, CA 92879 PHONE (951)817-3680 EMAIL jeremiah.acayturri@lennar.com APPLICANT NAME Jeremiah Acayturri ADDRESS 980 Montecito Dr.,Suite 302 PHONE (951) 817-3680 EMAIL jeremiah.acayturri@lennar.com CONTRACTOR'S NAME Lennar Homes of California, Inc. OWNER BUILDER? ❑✓ YES❑NO BUSINESS NAME Lennar Homes of California, Inc. ADDRESS 980 Montecito Dr.,Suite 302 Corona,CA 92879 PHONE (951) 817-3680 EMAIL jeremiah.acayturri@lennar.wm CONTRACTOR'S STATE LIC NUMBER 728102 LICENSE CLASSIFICATION A&B VALUATION $ $7,650.40 L SQ FT APPLICANT'S SIGNATURE DATE 07/30/2015 CITYSTAFF USE ONLY DEPARTMENT DISTRIBUTION CITY OF MENIFEE BUSINESS LICENSE NUMBER BUILDING PLANNING ENGINEERING FIRE GREEN SMIP INVOICE PAID AMOUNT AMOUNT `.' CASH =%{HECK# .'CREDITCARD VISA/MC PLAN CHECK FEES PAID AMOUNT « CASH ::CHECK# `. CREDITCARD VISA/MC OWNER BUILDER VERIFIED C YES 0 NO DL NUMBER NOTARIZED LETTER ; YES NO City of Menifee Building&Safety Department 29714 Houn Rd. Menifee, CA 92586 951-672-6777 www.cityofinenifee.us Inspection Request Line 951-246-6213 SYSTEM INFORMATION BUYER ACKNOWLEDGES THAT THE SOLAR MODULES TO BE INSTALLED ITEM OTY MFR. MODEL ON THE ROOF OF THE LOCATIONS INDICATED BOYMTHEILL BE ILWSTRATIONNTIALLY IN THE �ITY 0 MENI SYSTEM SIZE 2KW 2.9 MODULE II PCS. HYUNDAI I HIS-S265RG(265W) BUYER: INVERTER 1 II PCS JENPHASE I M215-60-2LL-S82It'f - Y 1otiILDI 0 AN ROOF TYPE TILE W/COMPOSITE SHINGLE UNDER AR Y DATE:— --_ _//�� SUB-ARRAY INFORMATION PLAN PPRO ARRAY#1 ARRAY#2 ARRAY#3 MOD OTY II NA NA BUYER: TILT 23, NA NA AZIMUTH I8O° NA NA DATE: City of Menifee HEED 19 Building Dept JUL 3 1 Ij1j 'Approval of bese plans s approval of,ai ty violation i Re c e i v 1 regulations and ordinance, jobsite until ccmpletion, 19'-6"ARRAY 20'-4"FLASHING 6'-7Y" L9TTI TF I SOLAOECK WIRE TRANSITION BOX (UNDER ARRAY) PV AC DISCONNECT « EXTERIOR-GARAGE UTILITY METER 8� - MAIN SERVICE PANEL (VERIFIED BY BUILDER) A J V 1_ • V NOTE:DIMENSIONS.ARE SHOWN IN PLANE OF ROOF N PLAN ELEVATION B ORIENTATION 2 LOT#187 CAMELLIA @ THE LENNAR ORIGINAL BY: ERIK MAY DATE 15.07,28 �( 'C�' 980 MNNTECITO DRIVE,#302 REVIEWED BY:UIMMY METER DATE 15.07.28 1.°.i r:�„+y}}E+�}- CORONA,/EA 92879 - REV.# BY DATE., DESCRIPTION Vn(3mc3st;6 SOLAR DWG TITLE: PAGE#: SCALE: SITE LOCATION: INDIVIDUAL 4577 BmaCO8greet PLOT PLAN 1 1/16'=1'-O' MENI ASHTON COURT Ba303,4 7.03M 4 MENIFEE,CA 303447.0300 SYSTEM LAYOUT E ) AFETY 6 Im A ®' 1 V _ 182 183 r; ial not be cons 179 180 �181 ,fa yprovision :z7 lis set ofapl s :ate _ oPPCS Imo— 1,: 184... LOT "P" -- Z C' bceP 189 , 188 187�°°p ,�cb V 147 749 ~n: c / / N PLAN 2399 ELEVATION B ORIENTATION 2 LOT# 187 CAMELLIA @ THE LENNAR: ORIGINAL BY ERIK MAY DATE:15.07.28 II �/ 980 MONTECITO DRIVE, 02 REVIEWED BY:JIMMY METER DATE.E.O7.28 -- : LAKE—Cam*—c-:l— CORONA.CA 92879 E REV.# BY DATE I DESCRIPTION _ namast;e salve DWG TITLE: PAGE#: SCALE: SITE LOCATION: treet INDIVIDUAL 48]t Broadway CO8 304 PLOT PLAN 2 I/64"=1'-0' MENI ASNTON COURT Boulder,1703M SITE PLAN MENIFEE,CA 303.44]0300 MODULE SPECS AND CALCULATIONS INVERTER SPECS AND CALCULATIONS ITEM NOTE/CALC UNIT DETAIL ITEM NOTE/CALC I UNIT DETAIL LOCATION MENIFEE,CA INV. MAKE INVERTER SPEC ENPHASE TEMP,AMBIENT HIGH(TMAX) ASHRAE 2% °C 37 INV. MODEL INVERTER SPEC M215-60-2LL-S22-IG TEMP,AMBIENT LOW(TMIN) FASHRAE EXTR.MIN "C -2 INV:MAX POWER,(WAC MAX) INVERTER SPEC WATTS(AC) 225 EPAR'I TEMP.MODULE TEST(TTEST) MODULE SPEC "C 25 INV. INPUT V,(VDC MAX) INVERTER SPEC VOLTS(oc) 48 TEMP,DELTA LOW(TOELTA) TMIN-TTEST 'C -27 INV. OUTPUT V,(Vac MOM) INVERTER SPEC VOLTS(AC) 240 MOD.MANUFACTURER MODULE SPEC HYUNDAI INV. OUTPUT FREQUENCY INVERTER SPEC HERTZ 60 MOD.PART NUMBER MODULE SPEC HIS-S265RG INV-OUTPUT CURRENT, IAC INVERTER SPEC AMPS(A0 0.9 MOD.POWER STC.(P) MODULE SPEC WATTS(Dc) 265 INV, PHASE QUANTITY INVERTER SPEC PHASE I MOD. POWER PTO MODULE SPEC WATTS(DO 238 COMPLIANCE INVERTER SPEC UL1741/IEEE1547 MOD. OPERATING VOLTAGE(VMP) MODULE SPEC VOLTS(Oc) 31.30 INV. GROUNDING INVERTER SPEC ISOLATED MOD. OPEN CCT. VOLTAGE(VOC) MODULE SPEC VOLTS(DO) 38.10 INV. OTY,MAX/BRANCH CCT. INV.OTYBC QTY 11 MOD.COEFF. VOLT/TEMP(COPE) MODULE SPEC V/°C -0.114 BRANCH OCT.OUTPUT, 1MAXBC (IAC•I NV.QTYBC) AMPS(Ac) 9.90 MOD.MAX VOLTAGE (VMAXMOD) (VOC+(TD-COEF)) VOLTS(oc) 41.18 INV. QUANTITY,TOTAL I INV.QTYT I OTY II MOM OPERATING CURRENT(IMP) MODULE SPEC AMPS(DIN 8.50 TOTAL SYSTEM OUTPUT, IMAXTS (IAC•INV.QTYT) AMPS(AC) 9.90 MOD.SHORT OCT. CURRENT 0sc) MODULE SPEC AMPS(DC) 9,00 MOD. MAXIMUM CURRENT(IMAX) Osc` 1.25) AMPS(DO 11.25 ued to be a! MIN.AMPACITY REO'D,PER NEC (IMAX- 1.25) AMPS(DC) 14.06 SERIES FUSE RATING,MAX MODULE SPEC AMPS(or) 15 of the Feder ELECTRICAL EQUIPMENT SCHEDULE OVedplans, .KEY OTY MANUFACTURER MODEL NOTES TRADE 1 11 HYUNDAI HIS-S265RG(265W) PV MODULE SOLAR 2 11 ENPHASE M215-60-2LL-S22-IG PV INVERTER SOLAR 3 1 RSTC/SOLADECK 0786-3R5 PV ROOF JUNCTION BOX,NEMA 3R SOLAR 4 1 CUTLER-HAMMER DG221URB PV AC DISCONNECT,NEMA 3R,24OV.30A SOLAR 5 1 ENPHASE ENVOY PV DATA MONITOR,120V SOLAR 6 1 TBD TBD 120V DEDICATED RECEPTACLE FOR ENVOY PV DATA MONITOR SOLAR 7 1 TBD TBD CATS PORT FOR SOLAR PV INTERNET CONNECTION TO HOME NETWORK BOX SOLAR B NOTE CUTLER-HAMMER LED PV BRANCH CIRCUIT BREAKERS; I X 15A-IP(ENVOY) SOLAR 9 NOTE CUTLER-HAMMER TOO PV BREAKER, Ix 20A-2P,LOCATE AT OPPOSITE END OF BUS FROM MAIN BREAKER SOLAR 10 1 TBD TBD SERVICE PANEL,MIN. 125A BUS BLDR.ELEC. 11 1 TEO TBD 1 UTILITY METER,IPH, 120/24OV,200A BLDR ELEC. 12 TBD TBD GROUNDING ELECTRODE LIFER BLDR. ELEC. CONDUCTOR SIZING CALCULATIONS INTERCONNECTION CALCULATIONS 1)CONDITION OF USE(COU): (AMPACITY'TEMP.DEBATE'FILL DEBATE)Vs.REQ'D(IMAX) ITEM UNIT PANEL "2)TERMINALS(TERM): AMPACITY AT TERMINALS. Vs.REQ'D,(IMAX- 1.25) PANEL MFR. CUTLER-HAMMER KEY ASIZECUIALINSULATION CALC. AMPACITY W70 TEMP. FILL RESULT REO'D OCD HUS RATING AMPS 200 TYPE BERATES DERATE BERATE (A) (A) USED(A) MAIN DISCONNECTA Z COU 30 *61� 22.80 9.90 ALLOWED PV PER NECTERM 2525 12.38 20 PVB COU 40 36.40 9.90 TERM 3535 12.38 20 C COU 40 36.L0 9.90 TERM 3535 12.38 20 CONDUCTOR SCHEDULE '.KEY CONDUCTORS CU/AL TYPE LOCATION TRADE A H#12 ENGAGE CABLE, -#6G.FREE AIR CU TO ARRAY SOLAR B 1 3-#10, H#10 EGG CU NM-B(ROMEX) INTERIOR SOLAR C 1 3410, H#10 EGC ON NM-B(ROMEX) I INTERIOR SOLAR p I CAT5E,ETHERNET CABLE CU CAT5E INTERIOR SOLAR © 5 D — O o o • 7 SEE 0 NOTE I5 0 1 0 P 0 zOnrzE 0 e O3 G 12 EXTERIOR-GARAGE ROOF ELECTRICAL DIAGRAM 2.92KW LOT# 187 ORIGINAL BY: ERIK MAY DATE:15.07.28 LENNAR: CAMELLIA @ THE REVIEWED BY:JIMMY METER DATE:15.07.28980 .- LAKES _u ._...._.c..a.�_.r,�-. OA,T 18TO D91VE,#302 CORONA,CA 9 P.EV.# BY DATE I DESCRIPTION 11 ' namasOIIe DWG TITLE: PAGE#: SCALE: SITE LOCATION: Sireet INDIVIDUAL 4571 Ber,GO cVvay 004 PLOT PLAN 3 NITS MENI EE,CA COURT Boulder,C0 80304 MENIFEE,CA 303.44]0300 ELECTRICAL STRUCTURAL NOTES: SOLAR CONTRACTOR- S ALL PV ROOF ATTACHMENTS WILL BE SPACED ALONG MODULE RACKING RAILS AT NOT GREATER THAN 48'O.C. 2)ALL PV ROOF ATTACHMENTS WILL BE STAGGERED BY ROW AMONGST THE ROOF FRAMING MEMBERS,Tq.(MA,XIMUM.EXTENT POSSIBLE. I h ENT. 3)ROOF PENETRATIONS ASSOCIATED WITH SOLAR RACKING WILL BE SEALED WITH AN APPROVED SEALANTT I 4)SOLADECK WIRE TRANSITION BOX WILL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS, IT WILL BE FLASHED AND SEALED. 5)PV ARRAY WILL BE A MINIMUM OF 3"ABOVE THE COMPOSITE SHINGLE ROOF SURFACE. 6)THE UNIRAC SOLARMOUNT RACKING SYSTEM AND SOLAR PV ARRAY WILL BE INSTALLED ACCORDING TO THE UNIRAC SOLARMOUNT CODE-COMPLIANT INSTALLATION MANUAL,VERSION 227.5,PUB 140113-ICC,JANUARY 2014. 7)UNIRAC TOP CLAMPS REQUIRE A ONE INCH OF)SPACE BETWEEN PV MODULES. SOLARMOUNT RAILS MUST EXTEND A MINIMUM OF TWO INCHES(2")BEYOND THE EDGE OF THE PV ARRAY/SUB-ARRAY. 8)UNIRAC SOLARMOUNT REQUIRES THAT A THERMAL EXPANSION GAP BE INSTALLED FOR ANY RAIL LENGTH OF GREATER THAN 40'. 1 .0 7, ROOFING CONTRACTOR- 1 ,I U DISTANCE BETWEEN ARRAY EDGE AND TRANSITION FLASHING(COMPOSITION TO TILE)WILL BE.A MINIMUM OF 3'. 2)26 GAUGE INTERLOCKING FLASHING'SIDEWALL"TO BE INSTALLED ALONG THE LENGTH OF THE PV ARRAY AT ROOFING MATERIAL TRANSITION. IT SHALL BE APROVED PRIOR TO PV SYSTEM INSTALLATION. 3)PEEL-N-STICK BASE TO BE INSTALLED ONE FOOT(1')OR MORE BEYOND THE EDGE OF THE COMPOSITION SHINGLE,DOWN TO THE ROOF PAVE. PEEL-N-STICK BASE TO `' BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS. rmlt for,Q� 4)AREAS UNDER EACH PV ARRAY SHALL BE ROOFED WITH COMPOSITION SHINGLE. COMPOSITION SHINGLE SHALL RUN FROM ABOVE THE PV ARRAY TO THE ROOF EAVE. 5)TILE INSTALLED BELOW THE ARRAY TO BE INSTALLED ABOVE THE COMPOSITION ROOF PER ROOFER SPECIFICATIONS. state or aq 6)BIRDSTOP WILL BE INSTALLED AT THE UPPERMOST TRANSITION FROM TILE TO COMPOSITION SHINGLE. BIRDSTOP TO BE SPECIFIED BY ROOFER PRIOR TO INSTALLATION. ust be kept, ELECTRICAL NOTES: GENERAL- ])ALL PV EQUIPMENT WILL BE TESTED AND.LISTED FOR ITS USE BY A NATIONALLY RECOGNIZED TESTING LABORATORY(NRTL). 2)THE GROUNDING OF THE PHOTOVOLTAIC SYSTEM SHALL COMPLY WITH THE APPLICABLE VERSION OF THE NEC/CEC. 3)ALL GROUNDING ELECTRODE CONDUCTORS WILL BE INSTALLED IN A CONTINUOUS LENGTH EXCEPT WHERE SPLICED BY AN IRREVERSIBLE CONNECTOR.OR EXOTHERMIC WELD. 4)NON-CURRENT CARRYING METAL PARTS SHALL BE CHECKED FOR PROPER GROUNDING.NOTING THAT TERMINAL LUGS BOLTED ON AN ENCLOSURE'S FINISHED SURFACE MAY BE ELECTRICALLY INSULATED BECAUSE OF PAINT/FINISH. PAINT/FINISH AT POINT OF CONTACT SHALL BE PROPERLY REMOVED. 5)ROOF PENETRATIONS WILL BE COMPLETED AND SEALED PER APPLICABLE CODE. 6)ALL CONDUCTORS WILL HAVE A 90°C RATING TO ENSURE CODE COMPLIANCE. SOLAR CONTRACTOR- 7)MODULE CERTIFICATIONS WILL INCLUDE UL1703,IEC61646, IEC61730, 8)CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS. 9)RACEWAY POINT OF PENETRATION FROM EXTERIOR TO INTERIOR WILL BE SEALED TO PREVENT INGRESS OF WATER AND INSECTS. 10)DC WIRING IS LIMITED TO PV ARRAY FOOTPRINT W/ENPHASE MICRO-INVERTER SYSTEM. II)MODULE AND ENPHASE WIRING SHALL BE LOCATED AND SECURED UNDER THE ARRAY USING SUITABLE WIRING CLIPS. WIRING SHALL NOT MAKE CONTACT WITH THE ROOF SURFACE AND SHALL BE MANAGED IN A WORKMAN-LIKE MANNER. 12)EQUIPMENT GROUNDING CONDUCTORS WILL BE SIZED IN ACCORDANCE WITH NEC TABLE 250.122. 131 CONDUCTOR TERMINATIONS WILL BE TORQUED PER DEVICE LISTING,OR MANUFACTURER'S RECOMMENDATIONS. 14)A PV AGGREGATION PANEL(SUB PANEL)WILL NOT BE INCLUDED FOR SYSTEMS WITH ONE BRANCH CIRCUIT. 15)A DEDICATED 120V BRANCH CIRCUIT IS REQUIRED IN MASTER CLOSET(OR EQUIVALENT)FOR ENPHASE ENVOY MONITOR. 16)THE INTERCONNECTION BREAKER SHALL BE LOCATED AT THE OPPOSITE END OF THE BUSBAR FORM THE MAIN OCPD. SIGNAGE- 17)PV SYSTEMS SHALL BE CLEARLY MARKED IN ACCORDANCE WITH NEC ARTICLE 690 AND OTHER APPLICABLE STATE AND LOCAL CODES.. 18)ALL SAFETY MARKING/PLACARDS SHALL BE PERMANENTLY ATTACHED BY ADHESIVE OR OTHER MECHANICAL MEANS. 19)MARKING /PLACARDS WILL BE METAL OR PLASTIC WITH ENGRAVED OR MACHINE PRINTED LETTERING.BACKGROUND WILL BE RED WITH WHITE CAPITAL LETTERING OF MINIMUM HEIGHT t". 20)ALL WIRING/RACEWAYS/JUNCTION BOXES WILL BE MARKED'PHOTOVOLTAIC POWER SOURCE;OR EQUIVALENT;WIRING/RACEWAYS SHALL BE MARKED EVERY 10'. BUILDER ELECTRICAL AND SOLAR CONTRACTORS- 21)INSTALLATION SHALL BE COMPLETED IN A NEAT AND WORKMAN-LIKE MANNER. 22)SPACE REQUIREMENTS FOR ALL ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110.26. ORIGINAL BY: ERIK MAY DATE:15.07.28 LENNAR: CAMELLIA @ THE REVIEWED BY:JIMMY METER DATE:15,17.28 '- - 980 MONTECITO DRIVE.#502 REV.k BY DATE DESCRIPTION LAKES— - -.... CORONA,CA 92879 - 1 namast;6 SOIAR DWG TITLE: PAGE#: SCALE: SITE LOCATION: INDIVIDUAL 0.571Id.CC 83N PLOT PLAN 4 NTS MENI EE,CA COURT Bo303.4C080304 MENIFEE,CA 303.447.0300 NOTES CAUTION: POWER TO THIS B'LJILDING IS SUPPLIED BY .., THE UTILITY AND A SOLAR PV SYSTEM. DISCONNECTS ARE LOCATED AS SHOWN. ATE n In the SOLADECK WIRE TRANSITION BOX (UNDER ARRAY) PV AC DISCONNECT EXTERIOR-GARAGE _ UTILITY METER 8 MAIN SERVICE PANEL_/ (VERIFIED BY BUILDER) SERVICE BY QUALIFIED PERSONNEL ONLY CONTACT: SUNSTREET ENERGY GROUP I-877—SLR—POWR NOTE: SEE MASTER SET FOR ADDITIONAL PLACARD INFORMATION ORIGINAL BY: ERIK MAY DATE:15.07.28 CAMELLIA @ THE LENNAR: REVIEWED BY.JIMMY METER DATE:1507.28 LAfy� 980 MONTECITO DRIVE,#302 REV.# BY DATE DESCRIPTION CORONA,CA 92879.iu,w :5'U Vnc3mc3sr6 DWG TITLE: PAGE#: SCALE: SITE LOCATION: INDIVIDUAL 45]i&oaCO 3Street PLOT PLAN 5 NTS MENI EE.CA COURT Bo30344 080304 MENIFEE CA 30044].030D PLACARDS