Loading...
PMT15-02225 1 City of Menifee Permit No.: PMT15-02225 29714 HAUN RD. GCE MENIFEE, CA 92586 Type: Residential Electrical c°'"""'""`wk. MENIFEE Date Issued: 0 8/1 912 01 5 PERMIT Site Address: 29646 ASHTON CT, MENIFEE, CA 92584 Parcel Number: Construction Cost: $8,331.60 Existing Use: Proposed Use: Description of SOLAR TR 30422-3 CAMELLIA Work; 12 MODULES 3.18KW LOT184 Owner Contractor LENNAR HOMES OF CA LENNAR HOMES OF CALIFORNIA INC 980 MONTECITO DR#302 25 ENTERPRISE CORONA, CA 92879 ALISO VIEJO, CA 92656 Applicant Phone: 9493498269 JEREMIAH ACAYTURRI License Number: 728102 LENNAR HOMES OF CALIFORNIA INC 25 ENTERPRISE ALISO VIEJO, CA 92656 Fee Description Qtv Amount l$1 Solar, Residential or Srn I Cvmmeraiat i: . 252:R4 �. - Building Permit Issuance 1 27.00 SMIP RESIDENTIAL 1 2.00 $282.00 The Issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and specifications or from preventing builiding operations being carried on thereunder when in violation of the Building Code or of any other ordinance of City of Menifee. Except as otherwise stated,a permit for construction under which no work is commenced within six months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be forfeited. AA_Bldg_Permit Template.rpt Page 1 of 1 CUILDING & SAFETY PERMIT/PLAN CHECK APPLICATION r`Menifee DATE 07/30/2015 PERMIT/PLAN CHECK NUMBER 1"1 16— TYPE: ❑COMMERCIAL ❑✓ RESIDENTIAL ❑MULTI-FAMILY ❑MOBILE HOME ❑POOL/SPA ❑SIGN SUBTYPE: ❑✓ ADDITION ❑ALTERATION []DEMOLITION ❑ELECTRICAL ❑MECHANICAL [:]NEW []PLUMBING [:IRE-ROOF-NUMBER OF SQUARES DESCRIPTION OF WORK Solar Permit-Plan 2785-3.18kW/12 PCS Master Solar Plan Permit Number: PMT14-02630 PROJECT ADDRESS 29646 Ashton Ct Menifee, CA 92584 ASSESSOR'S PARCEL NUMBER LOT 184 TRACT 30422-3 OWNER NAME Lennar Homes of California, Inc. ADDRESS 980 Montecito Dr.,Suite 302 Corona, CA 92879 PHONE (951)817-3680 EMAIL leremiah.acayturri@lennar.com APPLICANT NAME Jeremiah Acayturri - ADDRESS 980 Montecito Dr., Suite 302 PHONE (951)817-3680 EMAIL leremiah.acayturri@lennar.com CONTRACTOR'S NAME Lennar Homes of California, Inc. OWNER BUILDER? ❑✓ YES❑NO BUSINESS NAME Lennar Homes of California, Inc. ADDRESS 980 Montecito Dr., Suite 302 Corona, CA 92879 PHONE (951) 817-3680 EMAIL )eremiah.acayturri@lennar.com CONTRACTOR'S STATE LIC NUMBER 728102 LICENSE CLASSIFICATION A&B VALUATION $ $8,331.60 SO FT L SO FT APPLICANT'S SIGNATURE TE 30/2015 CITY STAFF USE ONLY DEPARTMENT DISTRIBUTION ,^yam CITY OF MENIFEE BUSINESS LICENSE NUMBER BUILDING PLANNING ENGINEERING FIRE GREEN I SMIP V INVOICE y/' PAIDAMOUNT AMOUNT �o "CASH CHECK# OCREDITCARD VISA/MC PLAN CHECK FEES PAID AMOUNT CASH ` CHECKN CREDIT CARD VISA/MC OWNER BUILDER VERIFIED C,YES 0NO DL NUMBER A NOTARIZED LETTER U YES < NO City of Menifee Building&Safety Department 29714 Houn Rd. Menifee, CA 92586 951-672-6777 www.cityofinenifee.us Inspection Request Line 951-246-6213 SYSTEM INFORMATION BUYER ACKNOWLEDGES THAT THE SOLAR MODULES TO BE INSTBI,LED ITEM GUY HER. MODEL ON THE ROOF OF THE HOME WILL BE SUBSTANTIALLY IN THE iPi6T F MENI SYSTEM SIZE 3.13KW LOCATIONS INDICATED BY THE ILLUSTRATION. jl1�, I 1 MODULE 12 PCS. HYUNDAI HIS-S265RG(265W) BUYER. ---"v'LD NG AN INVERTER '12 PCS tENPHASE 1 M215-60-2LL-S22-IG ' ROOF TYPE TILE W/COMPOSITE SHINGLE UNDER ARRAY DATE:_—— _________— -- - SUB-ARRAY INFORMATION L PPR01 ARRAY#1 ARRAY#2 ARRAY#3 MOD OTY 12 NA NA City of Menitee BUYER:— _---____— - —— — — — ---_ TILT 23' NA NA Building Dept pATE- AZIMUTH 280' NA NA ED e e 'v : "Approval of here plans d approval of,a y violation( regulations an ordinance: 22'-9'ARRAY lobsite until cc mpletion. 23'-7"FLASHING I' SOLADECK WIRE I I TRANSITION BOX (UNDER ARRAY) TV DISCONNECT -- EXTEE RIOR-GARAGE UTILITY METER 8 MAIN SERVICE PANEL (VERIFIED BY BUILDER) 2® p NOTE:DIMENSIONS ARE SHOWN IN PLANE OF ROOF .A Y_) PLAN 2785 ELEVATION B-R ORIENTATION I LOT#184 : ORIGINAL BY: ERIK MAY DATE:15.07.2 LENNAR 8 CAMELLIA @THE REVIEWED BY JIMMY METER DATE 15.07.28 LAKES 980 ITO DRIVE,#307. REV.# BY PATE DESCRIPTION ... . �� � �.-.-�:e CORONA,NA,CA d CA 92879 n_qw ib 2mamasrd DWG TITLE: PAGE#: SCALE: roue SITE LOCATION: 4571 Broadway Street INDIVIDUAL 29646 ASHTON COURT Boulder,CO 80304 PLOT PLAN 1116'=1'-0" MENIFEE.CA 303"T0300 SYSTEM LAYOUT FEE D SAFE X BII - 11 72 saaR 176 w ap 175 173 Q iall not be! i = !f any provi! Mn , - This set of 182 183 ® Ret.t 1 q � _ .. . ,1 170 _.�.I oa9CS 1 n 1m 169 s— sal, 168 ea 186 I m O � 6 N PLAN 2785 ELEVATION S-R ORIENTATION I LOT#184 LENNAR: ORIGINAL BY: ERIK MAY DATE:15.07.28 CAMELLIA @ THE REVIEWED BY:JIMMY METER DATE:15.07.28 LAKES- _.. ,..,,,� 980 NA.CA I92 DRIVE,#302 REV.# BY DATE DESCRIPTION � 98RONA.CA 9OD — Op namasGe SOLAR OWG TITLE: PAGE#: SCALE: SITE LOCATION 4571 Broadway Street INDIVIDUAL 29646 ASHTON COURT Boulder,CO 80304 PLOT PLAN 2 1/64'=1'-0" MENIFEE,CA 30144Z0300 SITE PLAN i MODULE SPECS AND CALCULATIONS INVERTER SPECS AND CALCULATIONS ITEM NOTE/CALC UNIT DETAIL ITEM NOTE/CALC UNIT DETAIL LOCATION MENIFEE,CA INV, MAKE INVERTER SPEC ENPHASE TEMP,AMBIENT HIGH(TMAX) ASHRAE 2% 'C 37 INV. MODEL INVERTER SPEC M215-60-2LL-S22-IG TEMP,AMBIENT LOW(THIN) ASHRAE EXTR.MIN IC -2 INV. MAX POWER.(WAC MAX) INVERTER SPEC WATTS(AC) 225 DEPAF TEMP,MODULE TEST(TTEST) MODULE SPEC °C 25 INV- INPUT V.(VAC MAX) INVERTER SPEC VOLTS(DC) 48 TEMP,DELTA LOW(TDELTA) THIN-TTEST "C -27 INV. OUTPUT V.(VAc NON) INVERTER SPEC VOLTS(Ac) 240 MOD. MANUFACTURER MODULE SPEC HYUNDAI INV. OUTPUT FREQUENCY INVERTER SPEC HERTZ 60 MOD. PART NUMBER MODULE SPEC HIS-S265RG INV. OUTPUT CURRENT, IAC INVERTER SPEC AMPS(AC) 0.9 MOD. POWER STC(P) MODULE SPEC WATTS(OO) 265 INV, PHASE QUANTITY INVERTER SPEC PHASE I MOD. POWER RTC MODULE SPEC WATTS(DO 238 COMPLIANCE INVERTER SPEC UL174171EEE1547 MOD. OPERATING VOLTAGE(VMP) MODULE SPEC VOLTS()C) 31.30 INV. GROUNDING INVERTER SPEC ISOLATED MOD.OPEN CCT. VOLTAGE(VOC) MODULE SPEC VOLTS(DU 38,10 INV.OTY,MAX/BRANCH CCT. INV.QTYBcI QTY 12 MOD.COEFF. VOLT/TEMP(COEF) MODULE SPEC V/-C -0.114 BRANCH CCT.OUTPUT,IMA"c (IAC-INV.QTY6c) I AMPS(Ad MAO MOD. MAX VOLTAGE(VMAXMoo) (VOc a(TD"COEF)) VOLTS(Dc) 41J8 INV. QUANTITY,TOTAL INV.OTYT TY O 12 MOD,OPERATING CURRENT(IMP) MODULE SPEC AMPS(od 8.50 TOTAL SYSTEM OUTPUT,IMAXTs (IAc9NV...... AMPS(aU 10.80 MOD. SHORT CCT.CURRENT Osd MODULE SPEC AMPS(Ud 9.00 MOD. MAXIMUM CURRENT(TMAX) (Isc- 1.25) AMPS(00 11.25 1 trued tO be i MIN.AMPACITY REQ'D.PER NEC (IMAX- 1.25) AMPS(OC) 14.06 [ I, SERIES.FUSE RATING,MAX MODULE SPEC AMPS(DC) I5 V Of the fede ELECTRICAL EQUIPMENT SCHEDULE ip rovedplam KEY QTY MANUFACTURER MODEL NOTES TRADE 1 12 HYUNDAI HIS-S265RG(265W) PV MODULE SOLAR 2 12 ENPHASE M215-60-2LL-S22-IG PV INVERTER SOLAR 3 1 RSTC/SOLADECK 0786-3R5 PV ROOF JUNCTION BOX,NEMA 3R SOLAR 4 1 CUTLER-HAMMER DG221URB PV AC DISCONNECT,NEMA 3R,240V.30A SOLAR 5 1 ENPHASE ENVOY PV DATA MONITOR,120V SOLAR 6 1 TBD TBD 120V DEDICATED RECEPTACLE FOR ENVOY PV DATA MONITOR SOLAR 7 1 TBD TBD CATS PORT FOR SOLAR PV INTERNET CONNECTION TO HOME NETWORK BOX SOLAR 8 NOTE CUTLER-HAMMER TBD PV BRANCH CIRCUIT BREAKERS;I x 15AHP(ENVOY) SOLAR 9 NOTE CUTLER-HAMMER TBD PV BREAKER, Ix 2OA-2P,LOCATE AT OPPOSITE END OF BUS FROM MAIN BREAKER SOLAR 10. 1 TBD TBD SERVICE PANEL,MIN. 125A BUS BLDR. ELEC. 11 ii I TBD 1 TBD UTILITY METER, IPH, I20/24OV,200A BLDR ELEC. 12' 1 TBD TBD GROUNDING ELECTRODE DEER BLDR ELEC. CONDUCTOR SIZING CALCULATIONS INTERCONNECTION CALCULATIONS 0 CONDITION OF USE(COU): (AMPACITY.TEMP.DERATE-FILL DERATE)vs. REQ'D OMAX) ITEM UNIT PANEL 2)TERMINALS(TERM): AMPACITY AT TERMINALS-vs. REO'D.(IHAX`L25) PANEL MEN. CUTLER-HAMMER KEY SIZE CU/AL INSULATION CALC. AMPACITY W/0 TEMP. FILL RESULT REQ'D OCD BUS RATING AMPS 200 TYPE DERATES DERATE DEBATE (A) (A) USED(A) MAIN DISCONNECT AMPS 200 A #12 CU THWN-2 COU 30 .76 LO 22,80 10.80 ALLOWED PV PER NEC AMPS 40 TERM 25 25 13.50 20 PV OCPD DEVICE USED AMPS 20 B #G CU NM-B CON 40 .91 1.0 36.40 10.80 TERM 35 35 13.50 20 C #10 CU NMI COU 40 .91 1.0 36.40 10.30 TERM 35 35 IS.50 20 CONDUCTOR SCHEDULE KEY CONDUCTORS CU/AL TYPE LOCATION TRADE A -#12 ENGAGE CABLE, -#6G,FREE AIR CU TC-ER ARRAY SOLAR B 1 3-#10, 1-#10 EGC CU I NM-B(ROMEX) INTERIOR SOLAR L 1 3410, 1-#10 EGC CU I NM-B(ROMEX) I INTERIOR SOLAR p I CAT5U ETHERNET CABLE CU I CAT5E INTERIOR SOLAR 6 5Q D __O • o •0 0 SEE 0 NOTE 15 0$a/IP Q 20,21 C O O e _- I 12 _ I I I EXTERIOR-GARAGE ROOF ELECTRICAL DIAGRAM 3A8KW LOT#184 LENNAR: ORIGINAL BY: ERIK MAY DATE:15.0728 CAMELLIA @ THE REVIEWED BY:JI MY METER I DATE:15.07.28 -^ 9BO MONTECITO DRIVE.#302 REV.# BY I IALE I DESCRIPTION .CQRONA,CA 92879 • ..- ,.t:, �riamaste SOLAR DWG TITLE: PAGE#: SCALE: SITE LOCATION: teet INDIVIDUAL 4571-----a 8 3N PLOT PLAN 3 PITS MENIF E,CA COURT Boulder,C O30304 MENIFEE,CA 303.447.0300 ELECTRICAL STRUCTURAL NOTES: SOLAR CONTRACTOR- U ALL PV ROOF ATTACHMENTS WILL BE SPACED ALONG MODULE RACKING RAILS AT NOT GREATER THAN 48'O.C. 2)ALL PV ROOF ATTACHMENTS WILL BE STAGGERED BY ROW AMONGST THE ROOF.FRAMING MEMBERS,TO MAXIMUM EXTENT POSSIBLE. 3)ROOF PENETRATIONS ASSOCIATED WITH SOLAR RACKING WILL BE SEALED WITH AN APPROVED SEALANT. F 4)SOLADECK WIRE TRANSITION BOX WILL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS. IT WILL BE FLASHED AND SEALED. WEN n YY� 5)PV ARRAY WILL BE A MINIMUM OF 3"ABOVE THE COMPOSITE SHINGLE ROOF SURFACE- 6)THE UNIRAC SOLARMOUNT RACKING SYSTEM AND SOLAR PV ARRAY WILL BE INSTALLED ACCORDING TO THE UNIRAC SOLARMOUNT CODE-COMPLIANT INSTALLATION MANUAL,VERSION 227.3.PUB 1401I3-ICC,JANUARY 2014. 7)UNIRAC TOP CLAMPS REQUIRE A ONE INCH NH)SPACE BETWEEN PV MODULES.SOLARMOUNT RAILS MUST EXTEND A MINIMUM OF TWO INCHES(2")BEYOND THE EDGE OF THE PV ARRAY/SUB-ARRAY. 8)UNIRAC SOLARMOUNT REQUIRES THAT A THERMAL EXPANSION GAP BE INSTALLED FOR ANY RAIL LENGTH OF GREATER THAN 40'. / ROOFING CONTRACTOR- V 1)DISTANCE BETWEEN ARRAY EDGE AND TRANSITION FLASHING(COMPOSITION TO TILE)WILL BE A MINIMUM OF 3'. LLL 2)26 GAUGE INTERLOCKING FLASHING"SIDEWALL'TO BE INSTALLED ALONG THE LENGTH OF THE PV ARRAY AT ROOFING MATERIAL TRANSITION. IT SHALL BE APROVED PRIOR TO PV SYSTEM INSTALLATION. 3)PEEL-N-STICK BASE TO BE INSTALLED ONE FOOT(I')OR MORE BEYOND THE EDGE OF THE COMPOSITION SHINGLE,DOWN TO THE ROOF EAVE. PEEL-N-SIUCK BASE TO BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS. 4)AREAS UNDER EACH PV ARRAY SHALL BE ROOFED WITH COMPOSITION SHINGLE. COMPOSITION SHINGLE SHALL RUN FROM ABOVE THE PV ARRAY TO THE ROOF EAVE. (,' 5)TILE INSTALLED BELOW THE ARRAY TO BE INSTALLED ABOVE THE COMPOSITION ROOF PER ROOFER SPECIFICATIONS. 'I'mltfpl 6)BIRDSTOP WILL BE INSTALLED AT THE UPPERMOST TRANSITION FROM TILE TO COMPOSITION SHINGLE. BIRDSTOP TO BE SPECIFIED BY ROOFER PRIOR TO INSTALLATION. 1,State of lust be h ELECTRICAL NOTES: GENERAL- ])ALL PV EQUIPMENT WILL BE TESTED AND LISTED FOR ITS USE BY A NATIONALLY RECOGNIZED TESTING LABORATORY(NRTU. 2)THE GROUNDING OF THE PHOTOVOLTAIC SYSTEM SHALL COMPLY WITH THE APPLICABLE VERSION OF THE NEC/CEC. 3)ALL GROUNDING ELECTRODE CONDUCTORS WILL BE INSTALLED IN A CONTINUOUS LENGTH EXCEPT WHERE SPLICED BY AN IRREVERSIBLE CONNECTOR OR EXOTHERMIC WELD, 4)NON-CURRENT CARRYING METAL PARTS SHALL BE CHECKED FOR PROPER GROUNDING,NOTING THAT TERMINAL LUGS BOLTED ON AN ENCLOSURE'S FINISHED SURFACE MAY BE ELECTRICALLY INSULATED BECAUSE OF PAINT/FINISH. PAINT/FINISH AT POINT OF CONTACT SHALL BE PROPERLY REMOVED. 5)ROOF PENETRATIONS WILL BE COMPLETED AND SEALED PER APPLICABLE CODE. 6)ALL CONDUCTORS WILL HAVE A 90-C RATING TO ENSURE CODE COMPLIANCE. SOLAR CONTRACTOR- 7)MODULE CERTIFICATIONS WILL INCLUDE ULI703,IEC61646, IEC61730. 8)CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS. 9)RACEWAY POINT OF PENETRATION FROM EXTERIOR TO INTERIOR WILL BE SEALED TO PREVENT INGRESS OF WATER AND INSECTS. 10)DC WIRING IS LIMITED TO PV ARRAY FOOTPRINT W/ENPHASE MICRO-INVERTER SYSTEM. 11)MODULE AND ENPHASE WIRING SHALL BE LOCATED AND SECURED UNDER THE ARRAY USING SUITABLE WIRING CLIPS-WIRING SHALL NOT MAKE CONTACT WITH THE ROOF SURFACE AND SHALL BE MANAGED IN A WORKMAN-LIKE MANNER. 12)EQUIPMENT GROUNDING CONDUCTORS WILL BE SIZED IN ACCORDANCE WITH NEC TABLE 250,122. 13)CONDUCTOR TERMINATIONS WILL BE TORQUED PER DEVICE LISTING.OR MANUFACTURER'S RECOMMENDATIONS. 14)A PV AGGREGATION PANEL(SUB PANEL)WILL NOT BE INCLUDED FOR SYSTEMS WITH ONE BRANCH CIRCUIT. 15)A DEDICATED 120V BRANCH CIRCUIT IS REQUIRED IN MASTER CLOSET(OR EQUIVALENT)FOR ENPHASE ENVOY MONITOR. 16)THE INTERCONNECTION BREAKER SHALL BE LOCATED AT THE OPPOSITE END OF THE BUSBAR FORM THE MAIN OCPD. SIGNAGE- 17)PV SYSTEMS SHALL BE CLEARLY MARKED IN ACCORDANCE WITH NEC ARTICLE 690 AND OTHER APPLICABLE STATE AND LOCAL CODES. 18)ALL SAFETY MARKING/PLACARDS SHALL BE PERMANENTLY ATTACHED BY ADHESIVE OR OTHER MECHANICAL MEANS. 19)MARKING/PLACARDS WILL BE METAL OR PLASTIC WITH ENGRAVED OR MACHINE PRINTED LETTERING, BACKGROUND WILL BE RED WITH WHITE CAPITAL LETTERING OF MINIMUM HEIGHT g`°. 20)ALL WIRING/RACEWAYS/JUNCTION BOXES WILL BE MARKED"PHOTOVOLTAIC POWER SOURCE,'OR EQUIVALENT:WIRING/RACEWAYS SHALL BE MARKED EVERY 10'. BUILDER ELECTRICAL AND SOLAR CONTRACTORS- 21)INSTALLATION SHALL BE COMPLETED IN A NEAT AND WORKMAN-LIKE MANNER. 22)SPACE REQUIREMENTS FOR ALL ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110.26. ORIGINAL BY: ERIK MAY DATE:15.07.28 LENNAR: CAMELLLIA @ THE REVIEWED BY:JI MMY METER JIDATE:1507.28 LAKE-9—— 960 MONTECITO DRIVE.#302 REV.# BY DATE DESCRIPTION d-� CORONA,CA 9Z879,,K;;H1 .,y Vnamasb6 SOUR DWG TITLE: PAGE#: SCALE: SITE LOCATION: INDIVIDUAL Boul 4571 B r.CO8Street PLOT PLAN 4 NTS 29646 ASHTON COURT tlar,C080304 MENIFEE,CA 303.447.0300 NOTES CAUTION: POWER TO THIS BUILDING IS~SUPPLIED BY THE UTILITY AND A SOLAR PV SYSTEM. T DISCONNECTS ARE LOCATED AS SHOWN. �S tTE n J the SOLADECK WIRE TRANSITION BOX (UNDER ARRAY) PV AC DISCONNECT EXTERIOR-GARAGE UTILITY METER B MAIN SERVICE PANEL (VERIFIED BY BUILDER) SERVICE BY QUALIFIED PERSONNEL ONLY CONTACT: SUNSTREET ENERGY GROUP 1-877-SLR-POWR NOTE: SEE MASTER SET FOR ADDITIONAL PLACARD INFORMATION CAMELLIA @ T} E LENNAR: ORIGINAL BY: ERIK MAY DATE:150728 �/ 980 MONTECITO DRIVE,#302 REVIEWED BY:JIMMY METER OATS 15.07 28 L �._._. LAKES i_t-; i:::�,• CORONA,CA 92879 REV.#. BY DATE DESCRIPTION. T[' pnamast€ SOLAR DWG TITLE: PAGE#: SCALE: SITE LOCATION: INDIVIDUAL 457u Ber,CO 8Street PLOT PLAN 5 NTS MENIF ASCA COURT Boulder,C080304 MENIFEE.CA 303.44]0300 PLACARDS