Loading...
PMT15-01890 I I City of Menifee Permit No.: PMT15-01890 29714 HAUN RD, A> MENIFEE, CA 92586 Type: Residential Plumbing i MENIFEE Date Issued: 07/07/2015 i PERMIT 1 Site Address: 23978 ELSINORE LN, MENIFEE, CA Parcel Number: 350-103-061 92587 Construction Cost: $7,100.00 Existing Use: Proposed Use: Description of REPLACE SEPTIC TANK AND LEACH LINE Work: Owner Contractor MICHAEL JORDAN LE PEW INDUSTRIAL INC 23978 ELSINORE LANE 41735 ELM STREET#303 MENIFEE, CA 92587 MURRIETA, CA 92562 Applicant - Phone: 8889615971 TIM HUMPHREY License Number: 988020 LE PEW INDUSTRIAL INC 41735 ELM STREET#303 MURRI ETA, CA 92562 Fee Description Qtv Amount I$1 e Building Permit Issuance 1 27.00 $178.00 The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and specifications or from preventing builiding operations being carried on thereunder when in violation of the Building Code or of any other ordinance of City of Menifee. Except as otherwise stated,a permit for construction under which no work is commenced within six months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be forfeited. AA_Bldg_Permit_Template,rpt Page 1 of 1 City Of Menifee LICENSED DECLARATION I hereby affirm under penalty or perjury that I am licensed under provisions of ❑ I, as owner of the property an exclusively contracting with licensed Chapter 9(commencing with section 7000)of Division 3 of the Business and contractors to construct the project(Section 7044, Business and Professions Professions Code and my license is in full force and effect. Code:The Contractor's License Law does not apply to an owner of a property License Clase - `'�� License 9�8 a�o who builds or improves thereon, and who contracts for the projects with a Expires s -% Signatures licensed contractor(s)pursuant to the Contractors State License Law). WORKERS'COMPENSATION DECLARATION ❑ I am exempt from licensure under the Contractors'State License Law for the 0-1-hereby affirm under penalty of perjury one of the fallowing declarations: following reason: I have and will maintain a certificate of consent of self-insure for workers' By my signature below I acknowledge that, except for my personal residence in compensation,issued by the Director of Industrial Relations as provided for by which I must have resided for at least one year prior to completion of Section 3700 of the Lab/Code, for the performance of work for which this improvements covered by this permit, I cannot legally sell a structure that I have permit is issued. ///N built as an owner-building if it has not been constructed in its entirety by licensed Policy# contractors. I understand that a copy of the applicable law, Section 7044 of the Business and Professions Code,is available upon request when this ❑ I have and will maintain workers' compensation insurance, as required by p q application is section 3700 of the Labor Code, for the performance of the work for which this submitted or at the following Web site:htto//www.IeQinfo.ca.Clov/cziIaw.h1mI. permit is issued.My workers'compensation insurance carrier and policy number are: Carrier Property Owner or Authorized Agent Date Expires Policy# my Signature below, I certify to each of the following: I am the property Name of Agent Phone# owner or authorized to act on the property owner's behalf. I have read this (This section need not be completed if the permit is for application and the information I have provided is correct. I agree to comply one-hundred dollars($100)or less) with all applicablyt4y and county ordinances and state laws relating to building construction.I Othorize re esentatives of this city or county to enter the above- certify that in the performance of the work for which this permit is issued, I identified property f the ection purposes. shall not employ any persons in any manner so as to become subject to the workers' compensation laws of California, and agree that if I should become r 70 7• /S subject to the workers'compensation provisions of Section 3700 of the Labor Property Owner or Authorized Agent Date Code,I shall forthwith comply with those provisions.Date; / '/�y City Business License# 0_3 7 �Y- 7 q ` r7 �S/ Applicant;�(� n�W �.7 y WARNING: FAILURE TO SECURE WORKERS' HAZARDOUS MATERIAL DECLARATION COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS WILL THE APPLICANT OR FUTURE BUILDING ($100,000), IN ADDITION TO THE COST OF COMPENSATION, AYES OCCUPANT HANDLEA HAZARDOUS MATERIAL ORA DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE MIXTURE CONTAINING A HAZARDOUS MATERIAL LABOR CODE, INTEREST,AND ATTORNEYS FEES aTTO EQUAL TO OR GREATER THAN THE AMOUNTS CONSTRUCTION LENDING AGENCY SPECIFIED ON THE HAZARDOUS MATERIALS I hereby affirm that under the penalty of perjury there is a construction lending INFORMATION GUIDE? agency for the performance f the work which this permit is issued (Section WILL THE INTENDED USE OF THE BUILDING BY THE 3097 Civil Code) �✓ /� APPLICANT OR FUTURE BUILDING OCCUPANT REQUIRE - Lender's Name " "t DYES A PERMIT FOR THE CONSTRUCTION OR MODIFICATION FROM THE SOUTH COAST AIR QUALITY MANAGEMENT Lender's Address 0<5 DISTRICT(SCAQMD)SEE PERMITTING CHECKLIST FOR OWNER BUILDER DECLARATIONS GUIDE LINES I hereby affirm under penalty of perjury that I am exempt from the Contractor's PRINT NAME: License Law for the reasons)indicated below by the checkmark(s)I have placed ❑YES WILL THE PROPOSED BUILDING OR MODIFIED FACILITY next to the applicable items)(Section 7031.5. Business and Professions Code: BE WITHIN 1000 FEET OF THE OUTER BOUNDARY OF A Any city or county that requires a permit to construct, alter, improve, demolish, BIT SCHOOL? or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with I HAVE READ THE HAZARDOUS MATERIAL Section 7000)of Division 3 of the Business and Professions Code)or that he or OYES INFORMATION GUIDE AND THE SCAQMD PERMITTING she is exempt from licensure and the basis for the alleged exemption. Any CHECKLIST. I UNDERSTAND MY REQUIREMENTS violation of Section 7031.5 by any Applicant for a permit subjects the applicant to ❑NO UNDER THE STATE OF LI FORNIA HEALTH AND SAFETY a civil penalty of not more than($500).) CODE, SEaTAT 5 25533 AND 25534 CONCERNING ❑ I, as owner of the property, or my employees with wages as their sole HAZARDO L P R1�ING. compensation, will do ( )all ofor( )porting of the work, and the structure is PROP T t')iED AGENT not intended or offered for sale.(Section 7044,Business and Professions Code; The Contractor's Slate License Law does not apply to an owner of a property X who, through employees' or personal effort, builds or improves the property, provided that the improvements are not intended or offered for sale. If,however, the building or improvement is sold within one year of completion, the Owner- Builder will have the burden of proving that it was not built or improved for the purpose of sale). 1 APPLICATION& SAFETY PERMIT/PLAN CHECK Menifee DATE S� PERMIT/PLAN CHECK NUMBER 5-01 TYPE: 0 COMMERCIAL 'O-RESIDENTIAL "D MULTI-FAMILY C MOBILE HOME POOL/SP SUBTYPE: ADDITION o ALTERATION DEMOLITION ELECTRICAL O ME �AURfA�` Safety De t. NEW le'-PLUMBING 0RE-ROOF-NUMBER OF SQUARES DESCRIPTION OF WORK �C �I I c (mh l'C Zrci�� 4L c Received PROJECTADDRESS L L5Ioa, LL�N M ell, 4 -C ASSESSOR'S PARCEL NUMBER ?-)W - (d3 //�p 1 LOT TRACT OWNER NAME L t�\ 0, JL ADDRESS PHONE r'[ r- 5 `J EMAIL APPLICANT NAME L L ADDRESS .S ��o�� yv\Uv�"C PHONE �1 961 S'S71 EMAIL (to, © -Le Cc✓ AW5-F fi C4 CONTRACTOR'S NAME L GUcJ 1,-vt/-z1�s��(n� OWNER BUILDER? 0 YES 0 BUSINESS NAME L TI/Y�LS4-/C- ADDRESS LLL13S VLv \ 54 3 29 V' ��te/� G PHONE ��� r'/� l $ g - EMAIL 1 & l-c 4n v, I/ CONTRACTOR'S STATE LIC NUMBER o LICENSE CLASSIFICATION - Y� VALUATION $ -7/ IL) SO FT L SQ FT APPLICANT'S SIGNATURE DATE < 7( 7) CITYSTAFF USE ONLY DEPARTMENT DISTRIBUTION CITY OF MENIFEE BUSINESS LICENSE NUMBER BUILDING PLANNING ENGINEERING FIRE GREEN SMIP X INVOICE PAID AMOUNT AMOUNT CASH C)CHECK# i%CREDIT CARD VISA/MC PLAN CHECK FEES PAID AMOUNT - CASH %CHECK# CREDIT CARD VISA/MC OWNER BUILDER VERIFIED C%YES Ci NO DL NUMBER NOTARIZED LETTER C YES O NO City of Menifee Building&Safety Deportment 29714 Haun Rd. Menifee, CA 92586 951-672-6777 www.cityofinenifee.us Inspection Request Line 951-246-6213 COUNTY OF RIVERSIDE AAR EPAMWM OF ENVIRONMEi�i. HEALTH _ INSPECTION CARD }- APN: 350 103 O(0 S ON No.: EHS No.: n— Site Address: 5A,3a 7 Le yL� J0, L U To Schedule an Inspection Please Call (951) 955-8980 OWTS Component Initial Date Re-Inspection Ifir of Inspection Date Septic Tank F li -_Line / Bedc- 0 `K-- IN4 Seepage Pits ity of Septic Tank Abandonment APO. Se Lateral D REVIEW Riser_—= C@IVe Effluent Filters i i-Inspection - ofthe ar =Jy I TO BE POSTED AT JOB SITE IN PLAIN VIEW rt. 114 Please Note: ❑If this box is checked, upon approval of your OW75 installation, please call the Department.-of MI Environmental Health at(95I) 955-8980 and ask for the Accounting office to reconcile fees prior to calling the Riverside County, Building and Safety Department for final inspection. Please give the ON number above when you call. Ct- U 3COUNTY F RIVERSIDE 141 DEPARTMENT OF ENVIRONMENTAL HEALTH U c�c� tF laQ4 La�neS ►s- fflk. Sewage Disposal I.1- Dwelling 10`2-0 Gal. Septic Tank Q —Commercial 1740 Sq. Ft.of Leach Line Seepage Pits —No. Dia— _Connect to Sewer BI—TD P 1D — — Connect to Existing System City of Menifee • Installation of leach lines are not to exceed A-75e Building & Safety Dept. Install risers to grade, leaving lids acressible for cleaning. Approved JUL 0 7 2015 Cleanable Effluent filters must be in t-,i?d±o f lc;llta,e servicing. • No on-Site water softening r`ev -as shad be discharged into the septic $� system without clearance from chc Cai;fo;rra Regional Water Quality Conirrl Received Board. • Ail sewage disposal instalt3ri n;hail conf r AENIF(, • Any grading in the area of,t,e m to ti ar_urrent ItOC ' AND pr % o lace lines shall require new 1 approval by this d0pallr;K. pate: 6 v n(SIS. 1ROV Go•�4re��Ov— 10 d��Qrwiih2 uJ�LI � U o o ye srO c�)' l Q B S�' �; *01IN Of I �r 'V �5 1 ' � ilk I Y' p, ( S I V1mv L_ COUNTY OF RIVERSIDE A-1111*&%6,DFPAI,r, -i'MENT OF ENVIRO1.,1v1ENTA1 HEALTH LAND USE APPLICATION OFFICE USE ONLY ® 3880 Lemon Street•Suite 200•Riverside•CA•92501 —(951)955-8980 PE CODE: FEE: ❑47-950 Arabia Street•Suite A•Indio•CA 92201 —(760)863-7570 <S�j-'8 ell, EHS# 1570 V�l ON# uo ilwo LMS# APN:. TR/PM / LOT# USE OF PERMIT: Ai . Lfn�C. 2 Si/tom' l 'CS SECTION A Name 37p✓ 1 17 h oln OWNER: Address 1^ SMoLC cityVc1 Phone s-(7 27 /Email n AGENT/ Company Name L[ �,/ l(��L �!r a Agenl/Contractor P6/'- CONTRACTOR: Mailing Address L(Ip� _ V-\ .S 3-b Phone Email Si nature Date 2J/ LL City Of MBOIf PROPERTY INFO. Site Address City C16 Water A ency/Well Lot Size JUL U 7 28A SECTION B Below-Far Office Use Only CHECK BOX IF REQUIRED �v If any box is checked,this application shall be considered denied until the information is provided. a c e I Ve ❑ Holding Tank Agreements Required ❑Floor Plan and/or Plumbing Layout Required ❑Certificate of Existing OWTS Required(C42) ❑Special Feasibility Boring Report Required. ❑WOCS Clearance Required 0 Detailed Contour Plot Plan Required It to 5 foot intervals) ❑Soils Percolation Report Required SITE EVALUATION INSPECTION REMARKS. n Yvesl�e Ilnot iecolli EHS INITIALS/DATE SECTION C tOfi�. ❑NEW ❑REPAIR/REPLACEMENT ❑EXISTING ❑ PUMP ❑A ❑CONNECT TO SEWER FIXTURE UNITS# BDRMS# Soils Percolation/Boring Report By Date: Project= ` CA2 Certification By: Date: License# Pi— 6-7-z.-I5 99 9FOZ- Septic tank cap.: Soil Rate: Tested Depth: Max. trench depth: 1000 1,70 Sq, Ft. Bottom Area: Total Linear Ft.: Line(s): &0 100 Len the feet - Each 3 feet wide Sidewall Allowance: Ft.Rock/ Sq.ft. Running foot Rock below drain line: LiZ in. or lactic Chambers Leach Lineslbed special design for slope: ❑WA 0 Overburden Factor: Pit Diameter. No pits: Depth below Inlet(b y Pit Total Depth: Max.allowable depth: 7 T TRUCTION/INSTALLATION REMARKS'_ 7 N C N 'f` !SSG S ? S ct SECTION D This Application is 13<pproved O Denied regarding the design of the OWTS as indicated on the accompanied plot plan using the requirements set forth in Section C above.No c n truction is per fitted In the required reserved 100%Expansion area. EHS Signature: Date: Fi. trigIs DERSM-122Rey 10114 DlsTtmi: WHITE-GTfice Poe:YELLOW-Bldg.Dept PINK-Applicant V-4iltrator IM- and TW-Series Septic MARCH 2O14 Tank General Installation Instructions il N FILTRATOR anks BEFORE YOU BEGIN points provided at each of the Inlet and outlet ports according to the applicable Infiltrator Systems tanks must be installed accordion to state and/or local Inlet and Outlet Hole Locations section of this document The inlet and outlet regulations, which supersede the manufacturer's Installation instructions. may be drilled on either the sides or ends of the tank,as required based on If unsure of the Installation requirements for a specific site.contact the health applicable codes and site conditions.' department or permitting authority.The IM-Series referred to in this document •Indiana, Kentucky.Oregon, West Virginia.and certain Florida and Texaf'1 includes the IM-540. IM-10"o0, and IM-1530 tanks.The TW-Series includes the tanks are Kentufacturcky `// TW-1250 and TW-1500 tanks. 3.The gaskets supplied with the tank are compatible with Schedule 40 and SDFL) AWARNING:IMPLOSIONS MAY CAUSE SERIOUS INJURY 35 pipe using a 5-inch-diameter(125 mm)hole saw with IPA-Series tanks,and Follow Infiltrator Systems Inc.vacuum test instructions a 51.; inch-aameter(133 min)hole saw with TW-Series tanks. 4.Install the rubber gaskets at the inlet and outletMATERIALS AND f '1 EQUIPMENT 5.Using all four of the tank's integral lifting lugs, lower tank into excavation. �J 11 Infiltrator tank ❑Shovel 6.Slide the inlet and outlet pipes'through the gaskets.Soapy lubricant may be used to slide the pipe In. Cl Access port lic ls)' ❑Level 'For North Carolina,the inlet pipe shall be a straight pipe with no tee. ❑10 screws per lid" L 5-inch-diameter(125 mm) 7. Horizontally position the tee 1Yz inches(40 mm)from the access port rim. El inlet/outlet gaskets hole saw(IM-Series only) allowing the tee to fit into the recess In the access port lid(see detail). (included) ❑5.25-inch-diameter(133 mm) 8.Instal lids and risers(see Installing Risers section)as necessary.Rotate lid ❑Inlet/oudet tees- hole saw(TW-Series only) over access opening until!t indexes to tank and drops into position. ❑Tape measure El Utility knife _ _ 'PCITICNrEE1s'InrComlpAI of Menifee:FRCM PONTRIM lJ El Pipe, risers. etc. El PVC pipe glue with primer Access PORT RIM Building & Safety Def14. ❑Socket wrench 'tee and lid inclusion varies by cAe1E1 -- ` i�Excavator state/province - EPEE E.ewc CE� JUL 0 1 201- uo IIM INSTALLATION SITE SELECTION L INLET TEE 1080 (TYPICALI - 5HCW N1 INTERIOR 1. Do not Instal the tank in vehicular traffic areas.The tank Is designed for _ ������� non-traffic applications. !bcnj 2.The allowable soil cover depth is 6 to 48'inches(150 to 1.200 mini. I1A W,IllHCBO,PNmMu35 u�nmSmn,I ' G 0 18-inch(450 mm)max.in Florida for Cat.3 IM-and TW-Series tanks: nv-125GAIDM ISM 51 Into z75 mm) 48-inch(1200 min)max.in Florida for Cat.41M-Series tanks;36-inch _ - (900 mm)max.in Massachusetts,New Hampshire,North Carolina,and Oregon.3.The tank shall not be Installed where the subsurface water level outside thetank exceeds the height of the outlet pipe saddle. Follow Table 4 guidelines. n—l" EXCAVATING AND PREPARING THE SITE1. Unless buoyancy control measures are required, the excavation width and length should be 18 to 36 inches(450 to 900 mm)larger than the tank on each side or sized as necessary to ensure proper backfill compaction,as outlined in Steps 5-10 of"Backfilling the Tank" in this document.See Infiltrator IM gACKFII LING_ THE TANK ;t411'd10� and Tit -Set es Tank Buoyancy Control Guidance document,avalable online IS Ofthlfi at www.infiltratorsystems.com, for specific excavation requirements when Note:Infiltrator tanks do not require filling with water prior to backfill ..II installing buoyancy control measures. placement.Water filling and backfilling to the tank mid-height is require's�p 2. excavation depth shall account for the height of tank(55 inches(1,375 min) if the tank is left in either an open or backfilled excavation that may fill for the IM-Series tanks and 51 inches(1,275 mm)for the TW-Series tanks). with water from rain or other sources. Also account for 4 inches(100 mm)of bedding(if required)and cover depth 1.Backfill with suitable native soil(max.3-inch(75-mm)stone diameter).If native (permissible cover depth Is 0.5 to 4 feet(150 to 1,200 mm)of soil). soil is unsuitable,replace unsuitable fraction with suitable soil. If suitable sell Is Note: If the water level outside the tank exceeds the height of the outlet not locally available;contact Infiltrator Systems for assistance. pipe saddle,tank structural integrity may be compromised.Follow 2.Suitable soil shall include soil textural classes defined in the United Stases Table 4 guidelines. Department of Agriculture sail triangle.Suitable soil textural classes are based 3.Inspect bottom or excavation to verify suitability of native soil for tank on the tank installation depth,as measured from finished grade to the top os Installation.Soils with large, protruding,or share stones or other simile,objects tank. that may damage the tank are not suitable. a)For a tank soil cover depth of 0.5 to 2.0 feet(150 to 600 min),suitable soil 4.The tank may be installed either m suitable native soil(see Backfilling the Tank textures include. section)or a minimum 4-Inch(100 mm)layer of well-graded granular soil having particles less than 3 inches(75 mm)in diameter,or maximum 0.5-inch(13 min) r;„,� R",,N, diameter crushed stone. s11Ian,it tlryalan 5.Create a uniform,compacted, level surface to ensure that the bottom of the In Mkensas oITT- Lank Is evenly supported.Verify that the installation surface is flat. �rs��ea a+y,aAl mzr sin-„I,r- cld3.LacAilll>S'I b= ,Om >tp0 seal - La— _ Ira , 1M' =_0'._n._ in o nca " rw,as Ie �nzls�miM.cr��.l t i I Llr - in .n.a.1 alu ao ss m n ne into sLry nn Tall. mr"anMTI -I isaN cuv .w���I - biAr _DA,I TITTcue cen=..0 Losl _Trur.Innei i i j seem c,Av i ram sLs .yea !� mc' sLTmr. INSTALLING THE TANK / 1. Inspect the tank for damage before Installation. T^ 1111 '4N 4._ , 2. If the tank inlet and outlet penetrations are not drilled, drill holes using the drill al l b)For a tank sod cover depth that is greater than 2.0 feet and up to 4.0 feet(600 to if needed.Long-term gmindwater control measures such as,nderdraIns and 1,200 mm),suitable soil textures Include: Interceptortrenches may be sensible If the site Is amenable to construction of a control system and such systems are not prohibited by regulation or law,and the tan,, -— l location is notsubiect to flooding.Properly installed underdrains and groundwater ........ interceptor trenches may prevent the need for tank buoyancy corrol measures. Si Sato JP'e . aro d eai3rn I..". INSTALLING UNDER SHALLOW GROUNDWATER CONDITIONS A'kan5a59"h &1­1 For�nas win n��ese.,,,a'Sn4 „� Buoyancy control measures may be requ!red It the Infiltrator tank is to be installed clay wit'a�.Nun s1au r.-iii,9ra"el with lees than inches t smisu�e'e�sa,r,o'o.sided ia•'rn (300 mm)of soil bee cover,and where the water level outside the tank has the potential to rise 30 inches(750 MITI or more above the ;71 elevation of the tank bottom.Otherwise,no control measures are required(see Table 1).The need for buoyancy control measures must be determined basea on backfill cover depth and height of water outside of tank above the tank oottom - according to Table 1.Refer to Infiltrator IM-and TW-Series Tank Buoyancy Control - pM1e Guidance document for more information. Table 1:Tank models'and conditions requiring buoyancy control' _ 9A >u Lexr \ Sollcoverdepth above tank' ., ,.,r s,L. Water height above - -- —_ b in 150 mm to tank bottom ( ) Above 12 in 12 in(300 mml - _- (300 mm) Above outlet pipe saddle Do not Install Do not install 3. Back.ill should not have stones greater than 3 Inches(75 mm)in diameter o- excessive clods that do not break apart during placement and compaction. 36 in(sod ri m All models Nona Back`Iill must be capable of occupying the spaces between the tank ribs and outlet pipe saddle' beneath the haunches. 30 In(750 mm)to All models except Note:Rounded screened aggregate(e.g.,pea gravel)is not a suitable 36 in(goo mail IM-540 and IM-1060 None backfill. Less than 30in None 4. Standard field soil classification methods shall be used to determine the soil (750 mm) None textural class, 1.IM-540.IM-1060,TW-1250.NL1500.and IM-1530. Note:Under most Circumstances,the determination of soil cillatancy will 2 See Infirrator IM-and TW-Series Tank Buoyancy Control G.,cl for detailed mformaticn c not be required.Dilatancy shall be determined in the field using a test that the use of centrols. �(��I.�� 3.No controls are requited for soil cover depths exceeding 12 in(300 mmj. WWI Complees te instructions tions specialized at www ASTM D248stems.on 14.3. 4.The shall not be installed where the water level outside the tank exceeds:ne^eight oche Comp ante instructions can be found aththefiaunc www.infiltratorsystems.com outet pipe saddle Follow Table 4 g-sidelines. - 5. Place and compact soil by walking-in beneath the haunches of the tank. 6. Place backfill around the four sidewalls in an alternating manner,so that the backfill INSTALLING RISERS height along the four sidewalls is maintained within a 12-inch(300-mail tolerance. 1,Compatible risers include 24-inch(600 mm)diameter products sucn as 7, Do not backfill top of tank before sidewalls are completely backfilled. the Infiltrator TW-Riser,EZset by Infiltrator Polyl;,Inc.,and Tuf-TIteU 8. Continue to place backfill along the sidewalls in 12-inch(300-mm)lifts. Place Corporation,in addition to 24-inch(600 aim)diameter corrugated HDPE anot—A backfill between the ribs on the sidewalls such that the space between the IPEX Ultra Roo PVC pipe.Follow Infiltrator's IM-and TW-Series Tank Riser ribs is completely filled with soil. Connection Guidance. 9. Compact backfill material either by walking-in,hand tamping or mechanical 2.In Oregon only,watertightness testing shall include filling with water at leas:2 compaction(includes backhoe bucket).If mechanical compaction is inches above riser connection,with no more than 1 gallon leakage per 24 FmApermll used,such as a walk-behind tamper or backhoe bucket,a single pass is per OAR 340-073-0025(3). dent SW recommended.Compact each lift Prior to placement of next lift.Compact INSTALLING PUMPS AND RELATED EQUIPMENT 1MfMd' backfill from tank walls to excavation sidevialls. 10.Complete backfilling and grade the area. Pimps may DO supported on a stable, level 16xl6-inch(400x400-mm)platform positioned on the bottom of the tank.One 16x16-inch block or two 8x16-inch(200 11. A minimum 6-inch(150-mm)depth of suitable soil must be placed over the -aim x 400-mm)side-t ide blocks may be used. Limit block height to account for top of the tank.The balance of backfill placed to finish grade above the tank pumo neigh'and liquid levels during pump cycles.Blocks)should be placed below may be either suitable or unsuitable soil. an access opening and level upon the tank bottom.For two blocks,orient them 12.Establish a strong stand of erosion-resistant vegetation. perpendlcuaar to ribs on the tank bottom,If Present,for stability. Note:Grade to prevent the backfilled excavation from filling with surface Installation of products such as electrical conduit and wiring. pumps,water level runoff.If the water level in the backfilled excavation exceeds the height of control equipment.valves,siphon equipment,etc.shall be In accordance with:he the outlet pipe saddle,tank structural integrity may be compromised. product manufacturers instructions and compliant with applicable state or local rules and regulations.Appurtenances shall be fastened to the Tank riser system and not the VOUND aACKFILL FOR --MINIMUM B"SOILOOVER tank body or access opening rim.Where possible,appurtenances shall be installed POSITIVE DFWNAGE 1 P 9 p pp to facilitate maintenance and repair access v'.a the tank access openings. - - - -- - - - Note:Prefabricated pump vaults may be installed. -_T o GENERAL SPECIFICATIONS I ' i —— son 3-(75 ail • Failure to comply with installation instruc`lons will void war amv. PLACE ---- � mhwxlrnuM BETmEEN RIBSIF, I s I:EErr . L. PARTICLE SIZE • Prior to ground disturbance,check for subsurface obstructions and a^.Tildes in f I' conformance with applicable requirements. _ PLACE SOIL IN COMPACTEDNATIE 12"(300 mm) •One,Sting water temperature shall be less than 100'F 140'C). su!rASLE Native 'I I I ' ' arts AND g P SOIL encKFl L <-- COMPACT • In cold conditions,handle and backfill tank w•th care to prevent Impact damage. - - PLACEAND COMPACT •Tanks are not fire resisFart.Store away from ignition solaces. SOIL BENEATH rIAUNCNES • Removal of structural bulkheads is prohibited:removal of locking clips on the IM- 19'-36 (450 90011T) 'IM ID60 sho„1'.I vtsence Series tank mid-seam connection is also prohibited. OR SIZEDE E BAC •Onlysuitable for potable a cations If the tank bears the NSF/AVS'61 TO ENSUREPROPERNECESSARY ECAACKFILLING PROCEDURE P PP' cernflcatan mark.Otherwise,tank Is recommended for use In septic rainwaters SHORT AND LONG-TERM GROUNDWATER CONTROL sficnin ter storage,holding,and pump apoicatons,or other norl-parable uses. It may be necessary to implement groundwater control measures during tank • Infiltrator tanks are designed for installation underground. Installation,Maintain dry conditions by expanding fie excavation to create a shot_- •Contact Infiltrator Systems for above-ground use requiremeno. term groundwater collection sump for temporary piacerrsent of a dewatering pump J Table 2: Infiltrator Tank Nominal Volume Chart Height' Total liquid volume in tank at indicated height IM-540 IM-1060 IM-1530 TW-1250 TW-1500 in cm U.S.Gal ! Liters U.S.Gal Liters U.S.Gal Liters U.S.Gal Liters U.S.Gal Liters 1 3 3 11 3 11 17 64 14 53 17 64 2 5 8 30 13 49 34 128 30 115 37 140 3 8 14 53 2B 106 51 192 58 218 71 267 4 10 21 80 46 174 68 256 87 33G 107 404 5 13 29 109 65 246 94 357 117 444 143 543 6 15 37 141 86 326 122 483 148 558 180 683 7 18 46 173 107 405 152 573 178 674 218 825 8 20 55 207 129 488 180 681 209 79! 25^a 9^08 9 23 64 243 152 575 212 802 940 910 294 1,112 10 25 74 279 17"0 6E6 245 928 272 1.029 332 L257 11 28 84 317 200 757 280 1,061 304 1,149 371 1,104 12 30 94 356 225 852 312 1.182 336 1.270 410 1,551 13 33 105 396 251 950 351 1,328 368 1,353 449 1.700 14 38 116 437 277 1,049 387 1,483 400 1.515 489 1,849 15 38 127 480 303 1,147 422 1,597 433 1.6^-0 528 2.000 16 40 138 _ 523 330 1.249 464 1,756 466 ',.765 569 2,152 17 43 150 566 357 1,351 500 1,892 500 1892 609 2.305 18 46 161 611 384 1,454 537 2034, 533 2019, 650 2,459 19 48 173 656 411 1,556 575 2,177 567 2,146 690 2,614 20 50 186 702 438 1.658 614 2,322 601 2,275 732 2,769 21 53 198 749 465 1.760 652 2,468 636 2,407 774 21928 22 56 210 1 796 493 1.866 690 2.612 671 2,541 816 3.091 23 58 223 843 521 1972, 729 2,758 708 2,678 8fi0 3,256 24 51 235 891 549 2,078 770 2.914 745 2.819 905 3A25 25 64 248 1 940 577 2.184 808 3.058 781 2955 948 3,589 26 fi6 261 988 605 2290 847 3,208 815 3.086 990 3.747 27 69 274 1,038 633 2.396 887 3.356 849 3,215 1,031 3,903 28 11 287 1.088 662 2.506 928 3,513 883 3.342 1,072 4.057 T(', 29 74 300 1,137 691 2.616 968 3.665 916 1469 1.112 4.210 30 76 313 1,185 719 2,722 1,007 3.814 950 3.59= 1,152 4,362 norm 31 79 326 t233 747 2.828 1,043 3 966 982 3.719 1.192 4,514 32 81 338 1,281 775 2.934 1,087 4,113 1,015 3.842 1.232 4,663 W efty 33 84 351 1,328 802 3.036 1,126 4262 1.047 3.964 1,271 4,810 kW 011hk 34 86 363 1,375 830 3,142 1.165 4.410 1,079 4.084 1,309 4,956 35 89 375 1,421 857 3.244 1,204 4,55.7 1,110 4.203 1,347 5.101 36 91 387 1.466 884 3.346 1,242 4.701 1.141 4.390 1.385 5243 37 94 399 1,511 1 911 3,449 1,280 I 4846 1,172 4.436 1,422 5384 38 97 411 1,555 938 3,551 1,318 4,988 1,201 4548 1,458 5.521 39 99 422 1,598 965 3,653 1.355 5,131 1.230 4,857 1,494 5,65_ 40 102 433 1,640 992 3,755 1,393 5272 1,261 4,772 1,532 5.798 41 104 444 1,681 1,018 3.854 1,430 5.412 1.286 4.869 1,562 5.915 42 107 455 1.722 1,044 3,952 1,466 5,550 1.314 4972 1.596 6,042 43 109 465 1.761 1,069 4,047 1,502 5.680 1.340 5.07' 1.629 6.167 44 112 475 1,799 1,094 4,141 1,537 5.817 1,366 5,172 1.661 6.288 45 114 485 1.838 t.118 4.232 1.572 5,950 1.390 5.233 1.690 E,399 46 117 494 1.871 1,142 4,323 1,604 6.070 1.410 5.337 1.715 6.492 47 119 503 1.9C5 1,165 4.410 1.638 8.201 1,427 S.CO'- 1,737 E.57d 48 122 512 1,938 1.187 4,493 1,667 6,310 1.439 5,440" 1.750 5.626 49 124 520 1.970 t208 4,573 1,697 5.422 1,448 5.481 1,7a"2 6,669 50 127 528 1.999 1,228 4,648 1,724 6.527 - - _ _ 51 130 535 � 2,027 1,247 4,720 1,749 6.621 52 132 542 205C 1,265 4,789 1,766 6,684 53 135 547 2.071 1,278 4,812 1,777 6.726 54 137 551' 2,087 1.287 4,872 1,785' 1 6.758 1. Height measured from IOWernlost inside sl:rface at nottom of corrugation in tank. 2.The total capacity of the IM-540 tank is 552 gailons:the btal capacity of the IM-1530 tank is 1787 gallons. rrr INLET AND OUTLET HOLE LOCATIONS point location for the hole saw.The pilot drill bit on the hole saw should Drill height marks are provided on all Infiltrator tank models to guide inlet be positioned at the center of the drill height mark to align the hole saw and outlet hole drilling.A single drill height mark is provided at each end properly,On the TW-Series tanks, marks"A"(lower)and "B"(upper)are or side port on the IM-Series tanks(example illustrated below). Holes located at the inlet end, while marks "C"(lower)and"D"(middle)are may be drilled at the end or side inlet and outlet locations,as allowed by located at the Outlet end.Table 3 provides drilling and invert information state and/or local regulations.The drill height mark indicates the center by regulatory jurisdiction for the installation of 4-inch-(100-ram-) diameter pipe. Table 3:Inlet and Outlet Hole Locations" Inlet invert Height(in)tram] 1 Jurisdiction' Inlet Drill Outlet brill Invert Drop Outlet Invert Location Location (in)[man] Above Inside Above Height and Liquid Bottom of Tank Excavation Base' Level(in)[ram] j r r All All All 3.00 [76] 47.00 [1,994] 47,20 (1,1991 44.00 [1,118] r.r End End 3.00[761 47.00 (1,994] 47.20 [1,1991 44.00 [1,118] All Side Side 3.00 [76] 47.5011,207] 47.70[1,2121 44,50 [1,1301 Side End 3.50[89] 4T50 (1,207] 47.70 [1,2121 44.00 [1,118] End Side 2.50 [641 47.00 [1,994] 47.20 [1,1991 44.50[1,130] r - If FL B D 2.75 [70] 42.75 (1,086] 43.45 [1,102] 40.00[1,0161 DE, IA, MA, ON A D 2.00 [51] 42.00 [1,067] 42.70 [1,086] 40.00[1,016] AP, CA, CO, CT, ID, IN, KS, KY, MO, MT, ND,OR, PA,SD,TX, VT, WV B C 3.00 [76] 42.75 [1,086] 4145 [1,1021 39.75 [1,010] All Others A C 2.25 [57] 42.00 [1,067] 42.70 [1,086] 39.75 [1,0101 1.Indiana, Kentucky,Oregon,West Virginia,and certain Florida and Texas tanks are factory drilled. 2. Invert heights are measured from the lowest interior surface at the bottom of the tank to the Invert. 3.Invert heights are measured from the base of the excavation to the invert. 4.State, provincial,and local regulatory requirements supersede Table 3 Information. -Top of Tank INFILTRATOR SYSTEMS, INC.("Infiltrator") INFILTRATOI SEPTIC TANK LIMITED WARRANTY FIVE(5)YEAR MATERIALS AND WORKMANSHIP LIMITED WARRANTY A1 10 ii (a)This limited warranty is extended to the end user of an Infiltrator Septic Tank.A Septic Tank manufactured by Infiltrator,when Installed and operated in accordance with Infiltrators installation instructions slid local regulation f by a licensed installer, is warranted to you:Q)against defective materials and workmanship for five(5)years after installaflon.Infiltrator will,at its option.if repair the defective product or fill replace the defective materials. Infiltrators liability specifically excludes(he cost ei removal end/or installation of the Septic Tank. T aj t - Maximum allowable Water (b)In order to exercise Its warranty rights,you must notify Infiltrator in writing at Its corporate headquarters in Old B elevation outside of the tank Saybrook,Connecticut within fifteen 05)days of the alleged defect. corresponds to the Outlet (c)YOUR EXCLUSIVE REMEDY WITH RESPECT TO ANY AND ALL LOSSES OR DAMAGES RESULTING FROM All CAUSE WHATSOEVER SHALL BE SPECIFIED IN SUBPARAGRAPH(a)ABOVE.I NFILTRATOR SHALL 1N NO EVENT pipe saddle invert BE LIABLE FOR ANY CONSEQUENTIAL OR INCIDENTAL DAMAGES OF ANY KIND,HOWEVER OCCASIONED, WHETHER BV NEGLIGENCEOR OTHERWISE.SOME STATES DO NOTALLOW THE EXCLUSION OR LIMITATION- OF INCIDENTAL OR CONSEQUENTIAL DAMAGES 50 THIS LIMITATION OR EXCLUSION MAY NO APPLY TO YOU.THIS WARRANTY SPE CIFIC LEGAL RIGHTS AND YOU MAY ALSO HAVF.O fHER RIGHTS WHICH -Tank base VARY FROM s STATE STATE TO STATE.' (d)THIS LIMITED WARRANTY IS THE EXCLUSIVE WARRANTY GIVEN AF INFILTRATOR AND SUPERSEDES ANY PRIOR, CONTRARY, ADDITIONAL, OR DESSUBSEQCENT REPRES ENTXTENS, WHETHER ORAL OR L TfEINFILTRAN.WARRANTIES, DISCLAIMS AND EXCLUDES TO THE GREATEST EXTENT ALLOWED BY LAW ALL OTHER WARRANTIES, WY,HERFINE EXPRESS OR IMPLIED, OR STATUTORY, INCLUDING ANY IES OTHERWISE OF Table 4:Maximum Allowable Subsurface Water Elevation MERCHANTABILITY, FINESSE FOH A PARTICULAR PURPOSE AND ANY IMPLIED WARRANTIES OTHER WISE ARISING FROM COURSE OF DEALING, COURSE OF PERFORMANCE,OR USAGE OF TRADE. NO PERSON Vertical Distance Yo Maximum Allowable (INCLUDING ANY EMPLOYEE., AGENT, DEALER, OR REPRESENTATIVE) IS AUTHORIZED TO MAKE ANY Water Elevation Outside of Tank REPRESENTATION OR WARRANTY CONCERNING THIS PRODUCT.EXCEPT TO REFER YOU TO PHIS LINID WARRANTY.EXCEPT AS EXPRESSLY SET FORTH HEREIN,THIS WARRANTY IS NOT A WARRANTY OF FUTURE ED PERFORMANCE,BUT ONLY A WARRANTY TO REPAIR OR REPLACE. A-From Top of B- From Tank Base (a)YOU MAY ASSIGN THIS LIMITED WARRANTY TO A SUBSEQUENT PURCHASER OF YOUR HOME. Tank Model Tank it NO REPRESENTATIVE OF INFILTRATOR HAS THE AUTHORITY TO CHANGE THIS LIMITED WARRANTY IN ANY MANNER WHATSOEVER,OR TO EXTEND THIS LIMITED WARRANTY. IM-Series' 13"(330 mm) 43'(1,075 mm) CONDITIONS AND EXCLUSIONS x There are retrain conditions or apgOcations over which In Mtrater has no control. Defects or problems as a result lW-Series 11"(230 mm) 39"(975 ram) of such conditions or applications are not the raaporeibiiity of Infiltrator and are NOT anvered under this warranty, They include failure to Install the Septic Tank in accordance with instructions or applicable regulatory requirements 1.IM-Series tanks Include the IM-540,IM-1050,and IM-1530. or guidance,altering the Septic Tank contrary to rile installation Instructions and disposing of chemicals or other 2,TA-Series tanks Include the TW-1250 and TW-1500. materials contrary to normal septic tank usage. The above,.presents the Standard limited Warranty offered by Infiltrator.A limited numberm states and counties have different warranty requirements.Any purchaserof a Septic Tank should contact Infiltrators corporate headquarters in Old Saybrook,Connecticut,prior to such purchase to obtain a copy of the applicable warranty,and should carefully reed that warranty prior to the purchase of a Septic Tank. AI a Business Park Road Distributed By: P.O.Be,758 Old Saybrook,CT08475 860-577-7000•Fax 860-5/1 7001 INFILTRATOR" 1.900-221-4436 systems Inc. www.infiltratorsystems.com U.S,Patents;4 759 a6i5017,0.l5, 16,488; ,3300II 5401.1165a01459;5,511903,5718,163;6508.776-5839,81A anad' a Fnrans 1 329 959,`,004 64Omer lineal pandingJnNtreoo FCrbrar,0,.--ick4, and SEdrAturdar are rogsta.d tcuranytow of InnIfird'or System,lac.l 51tratui is a legislated t adere rk In Ns,av insists,Sy .,s me 11 are,sterc l radI I,Mexico. Omni McroL shrlg,Pol/Tuff Ch mbarSpas•.MFIHPcF,PociLack QLI:IkC,lt.O!lickPlay,Snap Lock urd S'rilg il-ccl -r .r tl_marka of Incl.=tor Sgs'crus Le PelyLok is a trademark of PalyLok,Inc TIFF-TITE;L a regi,tred tokc1 arx of TUF-TITE,INC: Dire nib Is a nedematR of IPEX Lin. 020141.ah1[rater StrT ms Inc.All rights reserved-Printed in U,S._ TANKet 031:I-er