Loading...
PMT15-00862 i City of Menifee Permit No.: PMT16-00862 29714 HAUN RD. Type: Residential Addition _ CC % MENIFEE, CA 92586 MENIFEE Date Issued: 04/15/2015 PERMIT Site Address: 28650 AVENIDA ESTRELLA, MENIFEE, Parcel Number: 341-082-017 CA 92587 Construction Cost: $2,500.00 Existing Use: 1 &2 Family Residence Proposed Use: Description of INSTALL 6'x 65'CITY STANDARD BLOCK WALL WITH 3 CITY STANDARD PILASTERS Work: Owner Contractor TOMASA TENORIO 28650 AVENIDA ESTRELLA MENIFEE, CA 92587 Applicant License Number: TOMASA TENORIO 28650 AVENIDA ESTRELLA MENIFEE, CA 92587 Phone: 9512440621 Fee Description gtv Amount Building Permit Issuance 1 27.00 GREEN FEE 1 1.00 $317.00 The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and specifications or from preventing builiding operations being carried on thereunder when in violation of the Building Code or of any other ordinance of City of Menifee. Except as otherwise stated, a permit for construction under which no work is commenced within six months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be forfeited. AA_SIdg_Permit Template.rpt Page 1 of 1 City Of Menifee LICENSED DECLARATION I hereby affirm under penalty or perjury that I am licensed under provisions of ❑ I, as owner of the property an exclusively contracting with licensed Chapter 9(commencing with section 7000)of Division 3 of the Business and contractors to construct the project(Section 7044, Business and Professions Professions Code and my license is in full force and effect. Code:The Contractor's License Law does not apply to an owner of a property License Class License No. who builds or improves thereon, and who contracts for the projects with a Expires Signature licensed contractor(s)pursuant to the Contractors State License Law). WORKERS'COMPENSATION DECLARATION ❑ I am exempt from licensors under the Contractors'State License Law for the ❑ 1 hereby affirm under penalty of perjury one of the following declarations: following reason: I have and will maintain a certificate of consent of self-insure for workers' By my signature below I acknowledge that, except for my personal residence in compensation,issued by the Director of Industrial Relations as provided for by which I must have resided for at least one year prior to completion of Section 3700 of the Labor Code, for the performance of work for which this improvements covered by this permit, I cannot legally sell a structure that I have permit is issued. Policy# built as an owner-building if if has not been constructed in its entirety by licensed contractors. I understand that a copy of the applicable law, Section 7044 of the ❑ 1 have and will maintain workers' compensation insurance, as required by Business and Professions Cade,is available upon request when this application is section 3700 of the Labor Code, for the performance of the work for which this submitted or at the following Web site:htto'//www Ieainfo ca aov/calaw html. permit is issued.My workers'compensation insurance carrier and policy number are: Carrier Property Owner or Authorize Agent Date Expires Policy# ❑ By my Signature below, I certify to each of the following: I am the property Name of Agent Phone# owner or authorized to act on the property owner's behalf. I have read this (This section need not be completed if the permit is for application and the information I have provided is correct. I agree to comply one-hundred dollars($100)or less) with all applicable city and county ordinances and state laws relating to building construction.I authorize representatives of this city or county to enter the above- 0 I certify that y the performance y the work for which this permit is issued, identified property for the i lion pur osg es. shall not employ any persons in any manner so as to become subject to the workers' compensation laws of California, and agree that if I should become j subject to the workers'compensation provisions of Section 3700 of the Labor p perty Owner or Author ed Agent Date Code,I shall forthwith comply with those provisions. YCity Business License# Date; Applicant; WARNING: FAILURE TO SECURE WORKERS' HAZARDOUS MATERIAL DECLARATION COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS WILL THE APPLICANT OR FUTURE BUILDING ($100,000), IN ADDITION TO THE COST OF COMPENSATION, OYES OCCUPANT HANDLE A HAZARDOUS MATERIAL OR A DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE MIXTURE CONTAINING A HAZARDOUS MATERIAL LABOR CODE, INTEREST,AND ATTORNEYS FEES ONO EQUAL TO OR GREATER THAN THE AMOUNTS CONSTRUCTION LENDING AGENCY SPECIFIED ON THE HAZARDOUS MATERIALS I hereby affirm that under the penalty of perjury there is a construction lending INFORMATION GUIDE? agency for the performance of the work which this permit is issued (Section WILL THE INTENDED USE OF THE BUILDING BY THE 3097 Civil Code) APPLICANT OR FUTURE BUILDING OCCUPANT REQUIRE Lender's Name DYES A PERMIT FOR THE CONSTRUCTION OR MODIFICATION Lender's Address El NO FROM THE SOUTH COAST AIR QUALITY MANAGEMENT DISTRICT(SCAQMD)SEE PERMITTING CHECKLIST FOR GUIDE LINES OWNER BUILDER DECLARATIONS I hereby affirm under penalty of perjury that I am exempt from the Contractor's PRINT NAME: License Law for the reason(s)indicated below by the checkmark(s)I have placed DYES WILL THE PROPOSED BUILDING OR MODIFIED FACILITY next to the applicable item(s)(Section 7031.5. Business and Professions Code: BE WITHIN 1000 FEET OF THE OUTER BOUNDARY OF A Any city or county that requires a permit to construct, alter, improve, demolish, ❑NO SCHOOL? or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with I HAVE READ THE HAZARDOUS MATERIAL Section 7000)of Division 3 of the Business and Professions Code)or that he or DYES INFORMATION GUIDE AND THE SCAQMD PERMITTING she is exempt from licensure and the basis for the alleged exemption. Any CHECKLIST. I UNDERSTAND MY REQUIREMENTS violation of Section 7031.5 by any Applicant for a permit subjects the applicant to ❑NO UNDER THE STATE OF CALIFORNIA HEALTH AND SAFETY a civil penalty of not more than($500).) CODE, SECTION 25505 25533 AND 25534 CONCERNING ❑ 1, as owner of the property, or my employees with wages as their sole HAZARDOUS MATERIAL r EPORtING. compensation, will do ( )all of or( )porting of the work, and the structure is PROPERTY OWNER OR AUTHORIZED AGENT not intended or offered for sale.(Section 7044,Business and Professions Code; The Contractor's State License Law does not apply to an owner of a property X who, through employees' or personal effort, builds or improves the property, provided that the improvements are not intended or offered for sale.If,however, the building or improvement is sold within one year of completion, the Owner- Builder will have the burden of proving that it was not built or improved for the purpose of sale). BUILDING & SAFETY PERMIT/PLANPERMIT/PLAN CHECK APPLICATION zJi f -� Menifee DATE Z-11zzi PERMIT/PLAN CHECK NUMBER a TYPE: {) COMMERCIAL 4RESIDENTIAL C MULTI-FAMILY 0 MOBILE HOME O POOL/SPA C)SIGN SUBTYPE: "ADDITION •O ALTERATION DEMOLITION "' ELECTRICAL O MECHANICAL C) NEW O PLU/MBING :) RE-ROOF-NUMBER OF SQUARES DESCRIPTION OF WORK G 68 Building & Satety 0 pt. PROJECTADDRESS _dKs .. ! fit' APR 0 7.201 ASSESSOR'S PARCEL NUMBER LOT TRACT OWNER NAME ADDRESS PHONE j � j/� OJU GJ—. rJ�2 ( EfiT R I ' 95' q I O-a> APPLICANT NAMEy / ADDRESS q �� PHONE If7 �y('- (>E2f EMAIL CONTRACTOR'S NAME OWNER BUILDER? YES ONO BUSINESS NAME ADDRESS PHONE EMAIL CONTRACTOR'S STATE LIC NUMBER LICENSE CLASSIFICATION VALUATION$ (3!� SO FT L SO FT APPLICANT'S SIGNATURE DATE OTYSTAFFUSEONLY DEPARTMENT DISTRIBUTION CITY OF MENIFEE BUSINESS LICENSE NUMBER BUILDING PLANNING ENGINEERING FIRE GREEN SMIP INVOICE PAID AMOUNT AMOUNT 'J CASH -CHECK# C CREDIT CARD VISA/MC PLAN CHECK FEES PAID AMOUNT %;CASH Q CHECK# J CREDIT CARD VISA/MC OWNER BUILDER VERIFIED C)YES C NO DLNUMBER NOTARIZED LETTER C YES O NO City of Menifee Building&Safety Department 29714 Houn Rd. Menifee, CA 92586 951-672-6777 www.cityofinenifee.us Inspection Request Line 951-246-6213 +r r �•r , s • 'r +' r •: 1. / . 4 r TOP V1EW FOOTING I I ;:;:�% BLOCK 27" GROUT .:.:.:.:.. . L : : i STEEL REBAR =1 REBAR PLACEMENT _- �. —27' ILLUSTRATION I I SECTION VIEW I I BLOCK _ I = - - -- (1 2"X 12"OR 16"X 1 6") I I I SOLID GROUT MIN.24" 6' a : (4)-#4 REBAR REBAR MAX :ij (ONEATEACH CORNER) OVERLAP - _ ALL FOOTINGS ADJACENT TO i SLOPES TO BE AT LEAST 5'TO DAYLIGHT AS SHOWN BELOW.MIN 24" 24" REBAR ?j OVERLAP - s<O GRADE qF aoo oM . 5'MIN. FOOTING LIMITATIONS: FOOTNG REBAR$flNl. I PILASTER SPACING SHALL NOT EXCEED 20 FT.WHEN OTHER INFILL FENCING HAVE A61C1.6'•LONG 20" HOOKA An . IS ATTACHED. 16„ coNCR coves OF 311. 2.ON LY OPEN TYPE FENCING(SUCH AS WROUGHT IRON)MAY BE ATTACHED TO PILASTERS. SOLID TYPE FENCING MAY NOT BE ATTACHED TO PILASTER. 3.GATES AND DOORS ATTACHED TO PILASTER ARE LIMITED To 200#MAX. WEIGHT AND 4 FT.MAX.WIDTH PER PILASTER. 4.THIS PILASTER DESIGN IS INTENDED TO BE USED ONLY AS A FENCING 27"� FEATURE AND IS NOT INTENDED TO SUPPORT ANY OTHER LOADS. 5.FENCE HEIGHTS ARE REGULATED—CONSULT ZONING REGULATIONS BEFORE CHECK WITH THE BUILDING DEPARTMENT BEGINNING CONSTRUCTION. TO VERIFY IF A BUILDING PERMIT IS REQUIRED. 6.INSTALLATION OF ELECTRIC CIRCUITS,CONDUITS,OR LIGHTING FIXTURES WHEN A BUILDING PERMIT IS REQUIRED, REQUIRE ELECTRICAL PERMITS AND INSPECTION. THE FOLLOWING INSPECTIONS ARE ALSO REQUIRED: 7.FOOTINGSTO BE PLACED IN UNDISTURBED SOIL OR PROPERLY COMPACTED 1) FOOTING; EXCAVATION TRENCH CLEAN WITH STEEL AND ENGINEERED FILL. IN PLACE AND SUPPORTED 3"ABOVE AND AWAY FROM B.FOR DESIGN PARAMETERS,SEE FREESTANDING BLOCK WALL STANDARD. THE SURROUNDING THE EARTH/DIRT. WESTERN RIVERSIDE COUNTY CODE UNIFORMITY PROGRAM 2) REBAR/PRE-GROUT; VERTICAL REBAR IN PLACE- CITY OF MENIFEE INSPECTION PRIOR TO PLACING GROUT. ��+v 3) FINAL;AFTER GROUT IS PLACED-PRIOR TO ANY BUILDING DEPARTMENT DECORATIVE CAP PLACEMENT. MENIFEE, DISCLAIMER: MASONRY PILASTER ALTERNATE DESIGNS MAY BE POSSIBLE WHEN PROVIDED WITH AN ENGINEERED ANALYSIS.USE OF THIS STANDARD DESIGN IS (951)672$777 AT THE USER'S RISK AND CARRIES NO IMPLIED OR INFERRED 29714 HAUN ROAD,MENIFEE,CA 92586 GUARANTEE AGAINST FAILURE OR DEFECTS. FAX(951)6733843 2/24/20I4 1 �,CITYOFMENiFEE.US I PAGE I OF I FOOTING OPTION "A" FOOTING OPTION "B #4 HORIZONTAL REBAR (USE BOND BEAM BLOCK) I 6" OR 8" BLOCK "H„ -H" HEIGHT FROM TOP #4 HORIZONTAL AT 32" MAX. O.C. HEIGHT FROM TOP OF FOOTING (USE BOND BEAM BLOCK) Rt! OF FOOTING SEE TABLE"A" SEE TABLE"B" FOR REBAR SIZE FOR REBAR SIZE AND SPACING AND SPACING (LOCATE REBAR IN CENTER OF CELL) LOCATE REBAR IN CENTER OF CELL) FINISH GRADE (1)-#4 REBAR t6g" IIICONTINUOUSII-12" 101, _ (2)-#4 REBAR _6 CONTINUOUS IIII=-IIIREVERSE =I II_I II DIRECTION OF ' (IF W" HOOK EVERT OTHER REBAR (F�INGWIDTH) OOTI GWIDTH) OTHER SEE TABLE"A" SEE TABLE"B" ALL FOOTINGS ADJACENT TO TABLE "A" SLOPES TO BE AT LEAST 5'TO TABLE "B" DAYLIGHT AS SHOWN BELOW. uHrr "w" VERTICAL 11 11 11 VERTICAL REINFORCEMENT H W REINFORCEMENT 3' 17" #4 @ 48" O.C. 3' 19" #4 @ 48" O.C. 4' 20" #4 @ 48" O.C. �. 4' 22" #4 @ 48" O.C. 5' 23" #4 @ 48" O.C. S<oq 29" #4 @ 48" O.C. 6' 29" #4 @ 24" O.C. eoTFoM F` 6 34" #4 @ 24" O.C. FOOTING MIN. NOTES CHECK WITH THE BUILDING DEPARTMENT TO 1)THIS DESIGN DOES NOT ALLOW GRADE DIFFERENTIALS OF VERIFY IF A BUILDING PERMIT IS REQUIRED, MORE THAN 6"ON OPPOSING SIDES OF THE WALL THIS IS WHEN A PERMIT IS REQUIRED,THE FOLLOWING NOT A RETAINING WALL. INSPECTIONS ARE REQUIRED: 2)FENCE HEIGHTS ARE REGULATED^CONSULT ZONING 1)FOOTING;EXCAVATION TRENCH CLEAN WITH REGULATIONS BEFORE BEGINNING CONSTRUCTION. STEEL IN PLACE AND SUPPORTED 3"ABOVE AND 3)NO WATER COURSE OR NATURAL DRAINAGE SHALL BE AWAY FROM THE SURROUNDING EARTH/DIRT. OBSTRUCTED. 2)REBAR/PRE-GROUT;BOND BEAM REBAR AND 4)GROUT ONLY THE CELLS CONTAINING REBAR. THIS WALL VERTICAL REBAR IN PLACE-INSPECTION PRIOR TO IS NOT DESIGNED FOR ALL CELLS TO BE GROUTED. PLACING GROUT. 5)ALL REBAR TO BE ASI'M SPEC.A615,GRADE 40 MINIMUM. 3)FINAL;AFTER GROUT IS PLACED-PRIOR TO ANY 6)ALL REBAR LAP SPLICES TO BE 24"MINIMUM. DECORATIVE CAP PLACEMENT. 7)ALL MASONRY UNITS TO BE ASTM C-90 GRADE N. 8)REBAR TO BE CENTERED IN MASONRY CELLS. WESTMtN[RIVERSIDE COUPRY CODE UNIFORMITY PROGRAM 'SEE PAGE 2 FOR ADDITIONAL INFORMATION* CITY OF MENIFEE DISCLAIMER: BUILDING DEPARTMENT ALTERNATE DESIGNS MAY BE POSSIBLE - 1 WHEN PROVIDED WITH AN ENGINEERED FREESTANDING BLOCK WALL ANALYSIS. USE OF THIS STANDARD DESIGN s IS AT THE USER'S RISK AND CARRIES NO IMPLIED OR INFERRED GUARANTEE AGAINST (951)672-6777 29714 HAUN ROAD,MENIFEE,CA 92586 FAILURE OR DEFECTS. FAX(951)679-3843 2/ p/2014 1 WWWCITYOFMENIFEE.US I PAGE OF2 REBAR PLACEMENT ILLUSTRATION FOOTING OPTION B (TYPICAL) ALL REBAR SPLICES 2411 MIN. OVERLAP (TYPICAL) ONLY CELLS AND BOND BEAM COURSES WITH REBAR TO BE GROUTED (DO NOT SOLID GROUT ENTIRE WALL-USE GROUT STOP MESH AS APPROPRIATE) FOOTING OPTION A (TYPICAL) ALL REBAR SHALL HAVE A MINIMUM OF 311 CONCRETE COVER AT FOOTINGS DESIGN PARAMETERS. WESTERN RIVERSIDE COUNTY CODE UNIFORMITY PROGRAM ACTIVE SOIL PRESSURE (PSF) =30 4""" CITY OF MENIFEE PASSIVE SOIL BEARING(PSF) =150 BUILDING DEPARTMENT COEFFICIENT OF FRICTION =0.25 ENTRE r) ALLOWABLE SOIL BEARING(PSF) =1 500 .. '? WIND=80 MPH, EXPOSURE C Jam,,' FREESTANDING BLOCK WALL SEISMIC: - NA=1.3,Nv=1.6,Z=0.4,SOIL PROFILE=So (951)672-6777 29714 HAUN ROAD,MENIFEE,CA 92586 FAx(951)679-3843 2/24/2014 I W .CITYOFMENIFEE.US I PAGE20F2 GVTr Q. . EN3, IFE CITY OF MENIFEE MEMO DATE: April 8, 2015 TO: Jennifer Trujillo, Administrative Assistant FROM: Andy Powell, Assistant Engineer Land Development— PW Department SUBJECT: 28650 Avenida Estrella— Free Standing wall with Gate PROJECT NO: PMT15-00862 PC#1, 1 Hour I have completed the review of the subject Builidng Plans and have the following comments: 1. There is no restricted Access on Paseo La Plaza. Wall with Gate is OK. Pw/L MC CiT rc fir- f, NTEE APR 0 7 2015 IlBuilding & Safety RECEIVED a Internal Route Sheet Date: 4/7/15 Permit #: PMT15-00862 Address: 28650 AVENIDA ESTRELLA Contact Person: TOMASA TENORIO Phone #: F, Planning Routed Date: 4/7/15 Date Recv'd: Date Cleared: i Planner Initials: Project#: <Gate TURN APPROVED PLANS ' ! f -7DUE I _I / —16 : 4--7-IS Date Recv'd: 17'I5 Date Cleared: �� Engineer Initials: Plan #: APPROVED Transp. Clearance Received`: APR 0 3 2015 Notes: PUBLIC WORKS Notes: KjcJ KENis — -- Lso�l[—S LF Ili psDIf fC� *If Applicable