Loading...
PMT15-00332 City of Menifee Permit No.: PMT16-00332 29714 HAUN RD, 1 4WCCEI Pia. MENIFEE, CA 92586 Type: Residential Electrical MENIFEE Date Issued: 04/06/2015 i PERMIT Site Address: 26080 PINE VALLEY RD, MENIFEE, CA Parcel Number: 337-021-028 92586 Construction Cost: $15,000.00 Existing Use: Proposed Use: Description of INSTALL ROOF MOUNTED SOLAR SYSTEM, 14 PANELS, 1 INVERTER Work: Owner Contractor SUSAN KENNEDY R N R ROOFING INC 26080 PINE VALLEY ROAD P 0 BOX 8071 MENIFEE, CA 92586 REDLANDS, CA 92375 Applicant Phone: 9097987457 GREGG MILLER License Number: 657221 R N R ROOFING INC P 0 BOX 8071 REDLANDS, CA 92375 Fee Description Qtv Amount S�pia',es dent{a raSS[La I`�omr/ie�pla � � `"� � 52iQ0 Building Permit Issuance 1 27.00 GREEN FEE 1 1.00 $439.50 The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and specifications or from preventing builiding operations being carried on thereunder when in violation of the Building Code or of any other ordinance of City of Menifee.Except as otherwise stated,a permit for construction under which no work is commenced within six months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be forfeited. AA Bldg Permit_Template.rpt Page 1 of 1 City Of Menifee LICENSED DECLARATION I hereby affirm under penalty or perjury that I am licensed under provisions of ❑ I, as owner of the property an exclusively contracting with licensed Chapter 9(commencing with section 7000)of Division 3 of the Business and contractors to construct the project(Section 7044, Business and Professions Professions Code and mx license is in ful o d Code:The Contractor's License Law does not apply to an owner of a property License Class 9( — U License o who builds or improves thereon, and who contracts for the projects with a Expires U 3� Signature licensed contractor(s)pursuant to the Contractors State License Law). WORKERS'COMPENSATION DECLARATION ❑ I am exempt from licensure under the Contractors'State License Law for the ❑ 1 hereby affirm under penalty of perjury one of the following declarations: following reason: I have and will maintain a certificate of consent of self-insure for workers' By my signature below I acknowledge that, except for my personal residence in compensation,issued by the Director of Industrial Relations as provided for by which I must have resided for at least one year prior to completion of Section 3700 of the Labor Code, for the performance of work for which this improvements covered by this permit, I cannot legally sell a structure that I have permit is issued. Policy# built as an owner-building if it has not been constructed in its entirety by licensed _ contractors. I understand that a copy of the applicable law, Section 7044 of the t�f I have and will maintain workers' compensation insurance, as required by Business and Professions Code,is available upon request when this application is section 3700 of the Labor Code, for the performance of the work for which this submitted or at the following Web site:htto'//www leginfo ca gov/slaw html. permit is issued.;M w doers'compensation insurance carrier and policy number are: L Carrier Property Owner or Authorized Agent Date i � ( Yr 1 V�-V�( I Expires V�R /06LJ,5 Policy# Lq� 7 '55/7 7, O. , U �j r 1 I z"o f c-& ) Q//7_Q O' 0 By my Signature below, I certify to each of the following: I am the property Name of Agent 1U V (Ptrone1(7 /ll I d owner or authorized to act on the property owner's behalf. I have read this (This section need not be completed if the permit is for 4?plication and the information I have provided is correct. I agree to comply one-hundred dollars($100)or less) with all applicable city and county ordinances and state laws relating to building construction.I authorize representatives of this city or county to enter the above- 0 1 certify that in the performance of the work for which this permit is issued,I identife pry thy inspection purposes. shall not employ any persons in any manner so as to become subject to the workers'compensation laws of California, and agree that if I should become subject to the workers'compensation provisions of Section 3700 of the Labor i Property Owner or Authorized Agent Date Code, I shall forthwith comply with those provisions. /1 /- Clo r. (L) S City Business License# Date; (/ Applicant; Jo l L1 vve WARNING: FAILURE TO SECURE WORKERS' J HAZARDOUS MATERIAL DECLARATION COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS WILL THE APPLICANT OR FUTURE BUILDING ($100,000), IN ADDITION TO THE COST OF COMPENSATION, AYES OCCUPANT HANDLE A HAZARDOUS MATERIAL OR A DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE MIXTURE CONTAINING A HAZARDOUS MATERIAL LABOR CODE, INTEREST,AND ATTORNEYS FEES %NO EQUAL TO OR GREATER THAN THE AMOUNTS CONSTRUCTION LENDING AGENCY SPECIFIED ON THE HAZARDOUS MATERIALS I hereby affirm that under the penalty of perjury there is a construction lending INFORMATION GUIDE? agency for the performance of the work which this permit is issued (Section WILL THE INTENDED USE OF THE BUILDING BY THE 3097 Civil Code) APPLICANT OR FUTURE BUILDING OCCUPANT REQUIRE Lender's Name DYES A PERMIT FOR THE CONSTRUCTION OR MODIFICATION FROM THE SOUTH COAST AIR QUALITY MANAGEMENT Lender's Address KNO DISTRICT(SCAQMD)SEE PERMITTING CHECKLIST FOR OWNER BUILDER DECLARATIONS GUIDE LINES I hereby affirm under penalty of perjury that I am exempt from the Contractor's PRINT NAME: License Law for the reason(s)indicated below by the checkmark(s)I have placed ❑YES WILL THE PROPOSED BUILDING OR MODIFIED FACILITY next to the applicable items)(Section 7031.5. Business and Professions Code: BE WITHIN 1000 FEET OF THE OUTER BOUNDARY OF A Any city or county that requires a permit to construct, alter, improve, demolish, r0.N0 SCHOOL? or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter9 (commencing with I HAVE READ THE HAZARDOUS MATERIAL Section 7000)of Division 3 of the Business and Professions Code)or that he or QjKES INFORMATION GUIDE AND THE SCAQMD PERMITTING she is exempt from licensure and the basis for the alleged exemption, Any CHECKLIST. I UNDERSTAND MY REQUIREMENTS violation of Section 7031.5 by any Applicant for a permit subjects the applicant to ❑NO UNDER THE STATE OF CALIFORNIA HEALTH AND SAFETY a civil penalty of not more than($500).) CODE, SECTION 25505 25533 AND 25534 CONCERNING ❑ I, as owner of the property, or my employees with wages as their sole HAZARDOUS MATERIAL F}EPORYING. compensation, will do( )all of or( )porting of the work, and the structure is PROPER�R R AUTHORIZED AGENTR R AUTHORIZED AGENT not intended or offered for sale.(Section 7044,Business and Professions Code; The Contractor's State License Law does not apply to an owner of a property X A who, through employees' or personal effort, builds or improves the property, provided that the improvements are not intended or offered for sale.If,however, the building or improvement is sold within one year of completion, the Owner- Builder will have the burden of proving that it was not built or improved for the purpose of sale). Menifee PMT15-00332 0-;5c�ap'g 3/23/2015 EsGil Corporation In Partnership with Government for ottifding Safety DATE: 3/23/2015 ❑ APPLICANT ❑ JURIS. JURISDICTION: Menifee ❑ PLAN REVIEWER ❑ FILE PLAN CHECK NO.: PMT15-00332 SET: II PROJECT ADDRESS: 26080 Pine Valley Road PROJECT NAME: Miller & Kennedy 4 KW rooftop PV system ® The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. ❑ The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. ❑ The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. ❑ The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. ❑ The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. ❑ The applicant's copy of the check list has been sent to: ❑ EsGil Corporation staff did not advise the applicant that the plan check has been completed. ❑ EsGil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Telephone #: Date contacted: (by: ) Email: Fax #: Mail Telephone Fax In Person ❑ REMARKS: By: Morteza Beheshti Enclosures: EsGil Corporation ❑ GA ❑ EJ ❑ MB ❑ PC 2/17 ' W City of Menifee C _U_M_M T N S Building & Safety Dept. architecture b design MAR 16 2015 DATE: 5/7/14 Received STRUCTURAL ROOF CONNECTION REVIEW Project: Review of structural mount of solar roof panel Client: Steve Holmes Company: Solar Holmes Project Location: 26080 Pine Valley Rd, Menifee, CA 92586 Owner: Susan Kennedy Structural review of the attached structural notes from Zilla Phantom for the roof connection mounting system for a 2/12 - 6/12 roof slope. Job Site Conditions: Trussed roof connection 1/2" CDX Plywood roof sheathing Concrete tile roofing material with 3O1b base sheet Wind zone C - 110 mph wind load Use of Zilla Phantom mounting system for this specific project is acceptable based on the attached structural notes provided the following conditions are met: 1. Existing sheathing nailing is edge nailed at 6" on center at edges and 12" on center in the field with 8d nails. 2. Install 2 galy. deck screws @ 12" on center on all plywood edges below new solar panels 3. Install 5/16" x 6" gale. hanger bolts - 2 for each solar panel through roof truss or into 2x6 blocking attachment at each end of the roof trusses - embed 3" min @ each location 4. Mounts are to be placed as indicated in UNIRAC racking layout on sheet (4) 5. Roof attachment per lag pull-out detail on sheet (4) 6. Blocking 2'x6' shall be installed at all mounts that are within 3' of any roof edge 7. Roof fastening detail and spacing are on pages 2 of Zilla Phantom install manual 8. Install per 2013 California Building Code (CBC) Structural loading calculations • Existing roof - concrete tile @ 3 lbs / sf • New solar panels weigh 44 lbs total / 12.4 sf = 3.5 bls/sf • New roof load / sf = 6 lbs / sf roof load where solar panel are installed Q,j{, Al l ARC, i Dale R. Cummins AIA C14385 p w C 14385 11043 Stone River Drive, Rancho Cucamonga, CA 91737 9T�OF CAUyF�¢ / a � WIND UPLIFT CALCULATION STRUCTURAL ROOF CONNECTION REVIEW Wind Exposure "C" 110 miles per hour Withdrawal Force: Vup = 24.9 / sf Number of Panels: 14 Total Panel Area: 174 sf. Total Uplift: 4323 Number of Supports: 28 Uplift Per Suport: 154 Capacity (2) 5/16" lag Screw: 266 lb/in X 1.5 each = 798 # > 154# VALL: 798 > 154 OK USE 2 - 5/16" Lag screws per panel with embed 1 1/2 minimum QK QJ to use 5/16" long stainless steel lag screws with minimum 1 1/2" embed into existing top cord of roof truss, or roof joist, or 2" x 6" solid blocking that is attached to each side of the existing roof joists or top cord of the trusses. Dale R. Cummins C14385 11043 Stone River Drive, Rancho Cucamonga, CA 91737