Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
PMT14-03153
City of Menifee Permit No.: PMT14-03153 29714 HAUN RD. Type: Residential Electrical MENIFEE, CA 92586 MENIFEE Date Issued: 12/04/2014 PERMIT Site Address: 30177 BRISTOL GATE LN, MENIFEE, CA Parcel Number: 364-190-013 92584 Construction Cost: $8,331.60 Existing Use: Proposed Use: Description of SOLAR 12 PANELS 3.18KW Work: MASTER PLAN PMT14-02630 Owner Contractor LENNAR HOMES OF CA LENNAR HOMES OF CALIFORNIA INC 980 MONTECITO DR#302 25 ENTERPRISE CORONA, CA 92879 ALISO VIEJO, CA 92656 Applicant Phone: 9493498269 JEREMIAH ACAYTURRI License Number: 728102 LENNAR HOMES OF CALIFORNIA INC 25 ENTERPRISE ALISO VIEJO, CA 92656 Fee Description Qty Amount l$1 Building Permit Issuance 1 27.00 SMIP RESIDENTIAL 1 2.00 $282.00 The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and specifications or from preventing building operations being carried on thereunder when in violation of the Building Code or of any other ordinance of City of Menifee.Except as otherwise stated,a permit for construction under which no work is commenced within six months after issuance, or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be forfeited. AA_Bldg_Permit_Template,rpt Page 1 of 1 CITY OF MJluNIFEE PLCK No: P 29714 Haun Road Date: Date: Menifee, CA 92586 Phone: (951)672-6777 Ar"° Qv Fax:(951)679-3843 Ck#: Ck#: Building Combination Permit Gil W To Be Completed By Applicant Legal Description: Tract 30422-3 Camellia atthe Lakes IPlanning Case: F: L: Rt: R: Property Address: CMDL S Assessor's Parcel Numb— Lot 63 30177 Bristol Gate Ln 36N- 190�01 ProjecVrenant Name: Unit#: Floor#: T 30422-3 - Camellia at the Lakes Name: Lennar Homes of California, Inc Phone NA51-817-3680 IFax Ne. Property Address: Unit Number Zip Code 9 Owner 980 Montecito Dr. Suite 302 Corona CA Email Address: , eremiah.aca urri lennar.com Name: Phone No. Fax No. Jeremiah Acayturri 951-403-3715 Applicant Address: same as above Unit Number Zip Code Email Address: jeremiah.acayturri@lennar.com Name: Phone No. Fax No. Contractor Address: City FC tate Zip Code Contractor's City Business License o. Contractor's Cny State of California License No. lassification: B Number of Squares: Square Footage 3.18 kW/ 12 Panels Description of Work: S 2785 Cost of work:$$33 1.60 Applicant's Signature Date: 11/21/2014 To Be Co tell By City Staff Only. Indicate As PrReceived or N/A-Not Applicable 5 Completes sets of full mensioned,drawn to sale plans which include: 1 set of documents which include ❑ Title Sheet ❑ Elevations ❑ Electrical Plan ❑ Geo Tech/Solis Report(on cd only) ❑ Plot/Site Plan ❑ Roof Plan ❑ Mechanical Plan ❑ Title 24 Energy(on B Y x 11) Foundation Plan ❑ Structural Calculations ❑ ❑ Cross Section ❑ Plumbing Plan ❑ Single Line diagram for elec.services over 400 AMP ❑ Floor Plan ❑ Structural Framing Plan 6 Details ❑ Shoring Plan ❑ Sound Report-Residential Class Code: Indicate New Construction Alteration' Addition' Means/Melhods Work Type: Repair• - Retrofit' Revision to Existing Permit' Required? YES NO Proposed Building Use(s): Existing Building Use(s): #Buildings: #Units: #Stories: Will the Building Have a Basement? Y of N Bldg.Code Occupancy Group Indicate Indicate if YES or NO Indicate all Geo-tech.Haz.Zone At Project Construction nd"f ered that apply: Coastal Zone Completion: Type(s): C Of O Noise Zone Required? YES or NO Listed on Historic Resources Inventory CITY PLANNING STAFF ONLY APPROVALS: Costal Commiss Arch.Review Board Landmark Comm. Planning Comm.Zoning Administrator Fee Exempt: City Project Elec.Vehicle Charger Landmark Seismic Retrofit Special case:Bldg. OfiriWApproval Expedite Project(s): Child Care City Project Green Building Landmark Affordable Housing For Staff Use Only Building/Safety Permit Specialist City Planning ICivil Engineering EPWM-Admin Transportation Mgml. I Rent Control THANK YOU FOR HELPING US CREATE A BETTER COMMUNITY SYSTEM INFORMATION BUYER ACKNOWLEDGES THAT THE SOLAR MODULES TO BE INSTALLED ITEM OTY MFR. MODEL ON THE ROOF OF THE HOME WILL BE SUBSTANTIALLY IN THE SYSTEM SIZE 336 LOCATIONS INDICATED BY THE ILLUSTRATION. MODULE 1 12 PCS. BEND PM250MOI(265W) BUYER:_ — INVERTER 1 12 PCS JENPHASE I M215-60-2LL-S22-IG ROOF TYPE I TILE W/COMPOSITE SHINGLE UNDER ARRAY DATE--_------ - SUB-ARRAY INFORMATION ARRAY#1 ARRAY#2 ARRAY#3 MOD OTY 12 N/A N/A BUYER: TILT 23° XX° i AZIMUTH 27( 1 DATE:_________________________________ _- City of Menifee Building & Safety Dept. DEC 0 4 2014 19'-9X"-ARRAY eceiveCtITY OF ME IFEE 20'-7/"-FLASHING T-9^ BUILDING AND SAF'. PLAN APPR VAL REVIEWED 141 t 'Approval of these plat g shall not t SOLADECK WIRE TRANSITION BOX approval of,any violati not any pn (UNDER ARRAY) n — regulations and ordina ces. This so jobsite until completion, ;71 P AC DISCONNECT EXTERIOR-GARAGE _ - -- - -- -- -- - - i UTILITY METER e� MAIN SERVICE PANEL (VERIFIED BY BUILDER) r V Kv^J 0 NOTE:DIMENSIONS ARE SHOWN IN PLANE OF ROOF PLAN ELEVATION B ®z ORIENTATION ON 4 LOT#63 CAMELLIA @ THE LENNAR: ORIGINAL BY: FREDDY BERNALRUIV DATE:14.11.19 980 MONTECITO DRIVE REVIEWED BY:TOM FIDDES 1 DATEr 14.11.19 LAKES CORONA,CA 92789 REV.# BY DATE DESCRIPTION namast;c§ DWG TITLE: PAGE#: SCALE: SITE LOCATION: INDIVIDUAL 4671 Broadway CO 80304 Street PLOT PLAN I 1/16"=1'-0" MEIN]EE.CA L GATE LN Boulder, 703M MENIFEE,CA 303.497.030E SYSTEM LAYOUT 66 s 202 �Q ® k � t 65 I 203 TV_ I .s 1 `204 i 137-77 / v Co115fftkd 3 I 'sbnsdM — of aw" 62ru N PLAN 2785 ELEVATION B ORIENTATION 4 LOT#63 LENNAR: ORIGINAL BY: FREDDY BERNALRUI DATE:14AI.19 CAMELLIA @ THE REVIEWED BY:TOM FIDDES DATE:14 11.19 LAKES 980 MONTECITO DRIVE REV# BY DATE DESCRIPTION CORONA,CA 92789 VnamasV6 301A4 DWG TITLE: PAGE#: SCALE: SITE LOCATION. 4571 B o"ay Street INDIVIDUAL 30177 BRISTOL GATE LN BOUI(tef,GO 80304 PLOT PLAN 2 I/64"=1'-0° MENIFEE,CA 303.4470300 SITE PLAN MODULE SPECS AND CALCULATIONS INVERTER SPECS AND CALCULATIONS ITEM NOTE/CALC UNIT DETAIL ITEM NOTE/CALC UNIT DETAIL LOCATION MENIFEE,CA INV. MAKE INVERTER SPEC ENPHASE TEMP,AMBIENT HIGH(TMAX) ASHRAE 2% °C 37 INV. MODEL INVERTER SPEC M215-60-21-L-S22-IG TEMP,AMBIENT LOW(THIN) ASHRAE EXTR.MIN °C -2 INV. MAX POWER,(WAC MAX) INVERTER SPEC WATTS(AC) 225 TEMP,MODULE TEST(TTEST) MODULE SPEC °C 25 INV. INPUT V.(VOC MAX) INVERTER SPEC VOLTS(DU 48 TEMP.DELTA LOW(TOECTA) THIN-TTEST °C -27 INV.OUTPUT V,(VAc NOM) INVERTER SPEC VOLTS(As) 240 MOD, MANUFACTURER MODULE SPEC DENO INV. OUTPUT FREQUENCY INVERTER SPEC HERTZ 60 MOD.PART NUMBER MODULE SPEC PM250MOI INV.OUTPUT CURRENT, IAC INVERTER SPEC AMPS(As) 0.9 MOD POWERSTC(P) MODULE SPEC WATTS(DO 265 INV-PHASE QUANTITY INVERTER SPEC PHASE I MOO.POWER RTC MODULE SPEC WATTS(DC) 237 COMPLIANCE INVERTER SPEC UL1741/IEEE1547 MOD. OPERATING VOLTAGE(VMP) MODULE SPEC VOLTS(OC) 31.30 INV. GROUNDING INVERTER SPEC ISOLATED MOD. OPEN CCT. VOLTAGE(Vac) MODULE SPEC VOLTS(oc) 38.20 INV. OTY. MAX/BRANCH CCT. I"0 YecI OTY 12 MOD. COEFF. VOLT/TEMP(COEF) MODULE SPEC V/°C -0.115 BRANCH CCT.OUTPUT.IMAXec I (IAc'INV.QTY8c) I AMPS(AC) I 10.80 MOD, MAX VOLTAGE(VMAXMOD) (Voc+(TD•COEF)) VOLTS(DO 41.31 INV. QUANTITY,TOTAL INV.OTYT OTY 12 MOD.OPERATING CURRENT(IMP) MODULE SPEC AMPS(DC) 8.47 TOTAL SYSTEM OUTPUT. IMAXTS (IAC"INV.QTYT) AMPS(AC) 10.80 MOD.SHORT CCT. CURRENT 0sc) MODULE SPEC AMPS(Dc) 8,98 MOD. MAXIMUM CURRENT(IMAX) OSC- 1.25) AMPS(00 IL23 MIN.AMPACITY REO'D,PER NEC (IMAX' 1.25) AMPS(DU 14.03 SERIES FUSE RATING, MAX MODULE SPEC AMPS(DC) 15 ELECTRICAL EQUIPMENT SCHEDULE ,KEY CITY MANUFACTURER MODEL NOTES TRADE 1 12 BENQ PM250MOI(265W) PV MODULE SOLAR 2 12 ENPHASE M215-60-2LL-S22-IG PV INVERTER SOLAR 3 1 RSTC /SOLADECK 0786-3R5 PV ROOF JUNCTION BOX,NEMA 3R SOLAR ` ! 4 1 CUTLER-HAMMER DG221URB PV AC DISCONNECT,NEMA 3R. 240V,30A SOLAR M�{, 5 1 ENPHASE ENVOY PV DATA MONITOR,120V SOLAR 6 1 TBD TBD 120V DEDICATED RECEPTACLE FOR ENVOY PV DATA MONITOR SOLAR 7 1 TBD TBD CATS PORT FOR SOLAR PV INTERNET CONNECTION TO HOME NETWORK BOX SOLAR 8 NOTE CUTLER-HAMMER TBD PV BRANCH CIRCUIT BREAKERS;I X 15A-IP(ENVOY) SOLAR 9 NOTE CUTLER-HAMMER TBD PV BREAKER,I X 20A-2P,LOCATE AT APPOSITE END OF BUS FROM MAIN BREAKER SOLAR 10 I TBD TBD SERVICE PANEL,MIN. 125A BUS BLUR. ELEC. II TBD TBD 1 UTILITY METER,IPH, 120724OV,200A BLDR. ELEC. 12 TBD TBD GROUNDING ELECTRODE LIFER BLBR. ELEC. P_ CONDUCTOR SIZING CALCULATIONS INTERCONNECTION CALCULATIONS 1)CONDITION OF USE(COO): (AMPACITY-TEMP.DEBATE•FILL DEBATE)VS.REO'D(IMAX) ITEM UNIT PANEL �hl7 p111 2)TERMINALS(TERM): AMPACITY AT TERMINALS.VS.REQ'D.(IMAX- L25) PANEL HER. CUTLER-HAMMER Y KEY SIZE CU/AL INSULATION CALC. AMPACITY W/0 TEMP, FILL RESULT REO'D OCD BUS RATING AMPS 200 TYPE DERATES DEBATE DEBATE (A) (A) USED(A) MAIN DISCONNECT AMPS 200 bd*0 A #12 =NM-B COU 30 .76 1.0 22.80 10,80 ALLOWED PV PER NEC AMPS 40 TERM 25 25 13,50 20 PV OCPD DEVICE USED AMPS 20 B #10 COU 40 Al 1.0 36.40 10.80 TERM 35 35 13,50 20 c #10 COU 40 .91 1.0 36.40 10.80 TERM 35 35 13.50 20 CONDUCTOR SCHEDULE KEY CONDUCTORS CU/AL I TYPE LOCATION TRADE A 1-#12 ENGAGE CABLE,I-#6G,FREE AIR CU TC-ER ARRAY SOLAR B 1 3-#10, -#10 FCC CU NMI(ROMEX) INTERIOR I SOLAR C 3-#I0, L#10 EGC CU NMI(ROMEX) I INTERIOR I SOLAR D CAT5E,ETHERNET CABLE CU CAT5E INTERIOR I SOLAR © 0 0 _O e o eQ SEE 10 NOTE IS 0f o P 9 c 2GAQp O O e 3 N _ p G G 6 12= I I I EXTERIOR-GARAGE ROOF ELECTRICAL DIAGRAM 3.I1 LOT#63 CAMELLIA @THE ENNAR ORIGINAL BY; FREDDY BERNALRUI DATE:14.1119 980 MONTECITO DRIVE REVIEWED BY:TOM HOURS DATE:14.11.19 LAKES CORONA,CA 92789 REV.# BY DATE DESCRIPTION Vnctmasbd SOLAR DWG TITLE: PAGE#: I SCALE: SITE LOCATION: uest INDIVIDUAL 4671 Ber,CO 3N PLOT PLAN 3 NTS 30177 EE,CA L GATE LA BOWS C080804 MENIFEE CA 303.447.0300 ELECTRICAL STRUCTURAL NOTES. SOLAR CONTRACTOR- 0 ALL PV ROOF ATTACHMENTS WILL BE SPACED ALONG MODULE RACKING RAILS AT NOT GREATER THAN 48-O.C. 2)ALL PV ROOF ATTACHMENTS WILL BE STAGGERED BY ROW AMONGST THE ROOF FRAMING MEMBERS,TO MAXIMUM EXTENT POSSIBLE. 3)ROOF PENETRATIONS ASSOCIATED WITH SOLAR RACKING WILL BE SEALED WITH AN APPROVED SEALANT. 4)SOLADECK WIRE TRANSITION BOX WILL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS. IT WILL BE FLASHED AND SEALED. 5)PV ARRAY WILL BE A MINIMUM OF 3'ABOVE THE COMPOSITE SHINGLE ROOF SURFACE. 6)THE UNIRAC SOLARMOUNT RACKING SYSTEM AND SOLAR PV ARRAY WILL BE INSTALLED ACCORDING TO THE UNIRAC SOIARMOUNT CODE-COMPLIANT INSTALLATION MANUAL,VERSION 227.3,PUB 140113-ICC,JANUARY 2014. 7)UNIRAC TOP CLAMPS REQUIRE A ONE INCH(P)SPACE BETWEEN PV MODULES SOLARMOUNT RAILS MUST EXTEND A MINIMUM OF TWO INCHES(2")BEYOND THE EDGE OF THE PV ARRAY/SUB-ARRAY. 8)UNIRAC SOLARMOUNT REQUIRES THAT A THERMAL EXPANSION GAP BE INSTALLED FOR ANY RAIL LENGTH OF GREATER THAN 40. ROOFING CONTRACTOR- 1)DISTANCE BETWEEN ARRAY EDGE AND TRANSITION FLASHING(COMPOSITION TO TILE)WILL BE A MINIMUM OF 2)26 GAUGE INTERLOCKING FLASHING'SIDEWALL'TO BE INSTALLED ALONG THE LENGTH OF THE PV ARRAY AT ROOFING MATERIAL TRANSITION. IT SHALL BE APROVED PRIOR TO PV SYSTEM INSTALLATION. 3)PEEL-N-STICK BASE TO BE INSTALLED ONE FOOT(I')OR MORE BEYOND THE EDGE OF THE COMPOSITION SHINGLE,DOWN TO THE ROOF EAVE.PEEL-N-STICK BASE TO BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS. 4)AREAS UNDER EACH PV ARRAY SHALL BE ROOFED WITH COMPOSITION SHINGLE. COMPOSITION SHINGLE SHALL RUN FROM ABOVE THE PV ARRAY TO THE ROOF EAVE. 5)TILE INSTALLED BELOW THE ARRAY TO BE INSTALLED ABOVE THE COMPOSITION ROOF PER ROOFER SPECIFICATIONS. 6)BIRDSTOP WILL BE INSTALLED AT THE UPPERMOST TRANSITION FROM TILE TO COMPOSITION SHINGLE. BIRDSTOP TO BE SPECIFIED BY ROOFER PRIOR TO INSTALLATION. ENT ELECTRICAL NOTES: GENERAL- I)ALL PV EQUIPMENT WILL BE TESTED AND LISTED FOR ITS USE BY A NATIONALLY RECOGNIZED TESTING LABORATORY(NRTL). 2).THE GROUNDING OF THE PHOTOVOLTAIC SYSTEM SHALL COMPLY WITH THE APPLICABLE VERSION OF THE NEC/GEL. 3)ALL GROUNDING ELECTRODE CONDUCTORS WILL BE INSTALLED IN A CONTINUOUS LENGTH EXCEPT WHERE SPLICED BY AN IRREVERSIBLE CONNECTOR OR EXOTHERMIC 1 O.4)N — DI 4)NON-CURRENT CARRYING METAL PARTS SHALL BE CHECKED FOR PROPER GROUNDING,NOTING THAT TERMINAL LUGS BOLTED ON AN ENCLOSURE'S FINISHED SURFACE �� MAY BE ELECTRICALLY INSULATED BECAUSE OF PAINT/FINISH. PAINT/FINISH AT POINT OF CONTACT SHALL BE PROPERLY REMOVED. 5)ROOF PENETRATIONS WILL BE COMPLETED AND SEALED PER APPLICABLE CODE. 6)ALL CONDUCTORS WILL HAVE A 90-C RATING TO ENSURE CODE COMPLIANCE. lit for,OP 71 SOLAR CONTRACTOR- 7)MODULE CERTIFICATIONS WILL INCLUDE NS ARE ,BASEDIEC61646.ON MINIMUM ate or tits 8)CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS. 9)RACEWAY POINT OF PENETRATION FROM EXTERIOR TO INTERIOR WILL BE SEALED TO PREVENT INGRESS OF WATER AND INSECTS. t be k*Q 10)DC WIRING IS LIMITED TO PV ARRAY FOOTPRINT W/ENPHASE MICRO-INVERTER SYSTEM. 11)MODULE AND ENPHASE WIRING SHALL BE LOCATED AND SECURED UNDER THE ARRAY USING SUITABLE WIRING CLIPS. WIRING SHALL NOT MAKE CONTACT WITH THE ROOF SURFACE AND SHALL BE MANAGED IN A WORKMAN-LIKE MANNER. 12)EQUIPMENT GROUNDING CONDUCTORS WILL BE SIZED IN ACCORDANCE WITH NEC TABLE 250.122. 13)CONDUCTOR TERMINATIONS WILL BE TORQUED PER DEVICE LISTING,OR MANUFACTURER'S RECOMMENDATIONS. 14)A PV AGGREGATION PANEL(SUB PANEL)WILL NOT BE INCLUDED FOR SYSTEMS WITH ONE BRANCH CIRCUIT. 15)A DEDICATED 120V BRANCH CIRCUIT IS REQUIRED IN MASTER CLOSET(OR EQUIVALENT)FOR ENPHASE ENVOY MONITOR. 16)THE INTERCONNECTION BREAKER SHALL BE LOCATED AT THE OPPOSITE END OF THE BUSBAR FORM THE MAIN OCPO SIGNAGE- 17)PV SYSTEMS SHALL BE CLEARLY MARKED IN ACCORDANCE WITH NEC ARTICLE 690 AND OTHER APPLICABLE STATE AND LOCAL CODES. 18)ALL SAFETY MARKING /PLACARDS SHALL BE PERMANENTLY ATTACHED BY ADHESIVE OR OTHER MECHANICAL MEANS. 19)MARKING/PLACARDS WILL BE METAL OR PLASTIC WITH ENGRAVED OR MACHINE PRINTED LETTERING. BACKGROUND WILL BE RED WITH WHITE CAPITAL LETTERING OF MINIMUM HEIGHT J'. 20)ALL WIRING/RACEWAYS/JUNCTION BOXES WILL BE MARKED"PHOTOVOLTAIC POWER SOURCE:'OR EQUIVALENT;WIRING/RACEWAYS SHALL BE MARKED EVERY 10'. BUILDER ELECTRICAL AND SOLAR CONTRACTORS- 21)INSTALLATION SHALL BE COMPLETED IN A NEAT AND WORKMAN-LIKE MANNER. 22)SPACE REQUIREMENTS FOR ALL ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110.26. ORIGINAL BY: FREDDY BERNALRUI GATE:14.11.19 LENNAR: CAMELLIA @ THE REVIEWED BY:TOM DIODES I DATE 14.11J9 LAKES 980 MONTECITO DRIVE REV.# BY DATE DESCRIPTION CORONA.CA 92789 Vnamasb6 SOLAR DWG TITLE: PAGE#: I SCALE: SITE LOCATION: 4571 Broadway Street INDIVIDUAL 30177 BRISTOL GATE LN B..II,CO W304 PLOT PLAN 4 NTS MENIFEE,CA 303.447,0300 NOTES CAUTION: POWER TO THIS BUILDING IS SUPPLIED BY THE UTILITY AND A SOLAR PV SYSTEM. DISCONNECTS ARE LOCATED AS SHOWN. SOLADECK WIRE TRANSITION BOX (UNDER ARRAY) PV AC DISCONNECT EXTERIOR-GARAGE j UTILITY METER&� MAIN SERVICE PANEL (VERIFIED BY BUILDER) SERVICE BY QUALIFIED PERSONNEL ONLY CONTACT: SUNSTREET ENERGY GROUP I-877-SLR-POWR NOTE: SEE MASTER SET FOR ADDITIONAL PLACARD INFORMATION LENNAR: ORIGINAL BY: FREDDV BERNALRUI DATE-14.11.19 CAMELLIA @ THE REVIEWED BV.TOM FI DDEs DATE1A. ILI9 REG MONTECITO DRIVE REV.# BY DATE DESCRIPTION LAKES CORONA,CA 92789 na masbe a,.. TWO TITLE. PAGE#: SCALE: SITE LOCATION: 4571 B. dtl .y Street INDIVIDUAL 30177 BRISTOL GATE LN 8.ud.T,CO 80304 PLOT PLAN 5 NUS MERCER CA 303,4470300 PLACARDS