Loading...
PMT14-02126 { City of Menifee Permit No.: PMT14-02126 29714 HAUN RD. Type: Residential Electrical MENIFEE, CA92586 MENIFEE Date Issued: 08/18/2014 d PERMIT Site Address: 29282 NECTARINE ST, MENIFEE, CA Parcel Number: 333-621-003 92584 Construction Cost: $9,353.40 Existing Use: Proposed Use: Description of SOLAR-14 PANELS 3.7 KVV LOT 137 Work: MASTER PLAN PMT14-00706 TR 31582-1 Owner Contractor LENNAR HOMES LENNAR HOMES OF CALIFORNIA INC 980 MONTECITO DR#302 25 ENTERPRISE CORONA, CA 92879 ALISO VIEJO, CA 92656 Applicant Phone: 9493498000 JEREMIAH ACAYTURRI License Number: 728102 25 ENTERPRISE ALISO VIEJO, CA 92656 Fee Description City Amount I$1 Building Permit Issuance 1 27.00 SMIP RESIDENTIAL 1 4 2.00 $282.00 The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and specifications or from preventing builiding operations being carried on thereunder when in violation of the Building Code or of any other ordinance of City of Menifee. Except as otherwise stated, a permit for construction under which no work is commenced within six months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be forfeited. AA_Bidg_Permit_Template.rpt Page 1 of 1 CITY OF Mlul®lFEE PLCK No: P i 1 -0 'aI 29714 Haun Road Date: Dole: Menifee, CA 92586 Phone: (951)672-6777 Amount: Amount: Fax:(951)679-3843 Ck#: Ck#: Building Combination Permit �.se � Mefldldtrl\ To Be Completed By Applicant Legal Description: Menifee Hills / El Dorado T31582-1 I Planning Case: F: L. Rt; R: PmpertyAddress: Lot 137 29282 Nectarine St Assessor's Parcel Number. 333 621 003 Project/renant Name: Unit#: Floor#: T 31582-1 - Menifee Hills - Meridian Name: Lennar Homes of California, Inc Phone%1-817-3680 Fax No. Property Address: Unit Number Zip Code Owner 980 Montecito Dr., Suite 302 Corona CA 909 Email Address: , eremiah.aca urri lennar.com Name: Phone No. Fax No. Jeremiah Acayturri 951-403-3715 Applicant Address: same as above Unit Number Zip Code Email Address: jeremiah.acayturri@lennar.com Name: Phone No. Fax No. Contractor Address: City State Zip Code Contractor's City Business License No. Contractor's City State of California License No. Classificalion: B Number of Squares: Square Footage 3.7 kW/ 14 PCS / 14 PCS Description of Work: Solar P 09 Elevation A lCost of work:$9353.40 Applicant's Signature Date: 7/25/2014 To 135,9biffpleted By City Staff Only Indica a As R-Received or N/A-Not Applicable 5 Completes sets of fully dimensioned,drawn to sale plans which include: 1 set of documents which include ❑ Title Sheet ❑ Elevations ❑ FJectrical Plan ❑ Gap Tech/Solis Report(on cd only) ❑ Plot/Site Plan ❑ Roof Plan ❑ Mechanical Plan ❑ Title 24 Energy(on 8 1/x 11) ❑ Foundation Plan ❑ Cross Section ❑ Plumbing Plan ❑ Structural Calculations ❑ Single Line diagram for also.services over400 AMP ❑ Floor Plan ❑ Structural Framing Plan&Details ❑ Shoring Plan ❑ Sound Report-Residential Class Code: Indicate New Construction Alteration' Addition` MeanslMethods Work Type: I Repair" Retrofit' Revision to FJdsting Permit' Required? YES NO Proposed Building Use(s): Existing Building Use(s): #Buildings: #Units: it Stories: Will the Building Have a Basement? Y of N Bldg.Code Occupancy Group Indicate Indicate if YES or NO Indicate all Geo-tech.Haz.Zone At Project Construction Sprinklered that apply: Coastal Zone Completion: Type(s): C of O YES or NO Noise Zone Requiretl? Listed on Historic Resources Inventory CITY PLANNING STAFF ONLY APPROVALS: Costal Commiss Arch-Review Board Landmark Comm. I lPlanning Comm.Zoning Administrator Fee Exempt: City Project I JElec.Vehicle Chargerl I Landmark ISelsmic Retrofit speclai case:slag. Offcial Approval Expedite Project(s): Child Care City Project Green Building LandmarkI Affordable Housing For Staff Use Only Buf1ding/Salety Permit Specialist I City Planning I Civil Engineering EPvvM-Admin Iransponation Mgmt. I Rent Control THANK YOU FOR HELPING US CREATE A BETTER COMMUNITY SYSTEM INFORMATION BUYER ACKNOWLEDGES THAT THE SOLAR MODULES TO BE INSTALLED ITEM OTY PER, MODEL ON THE ROOF OF THE HOME WILL BE SUBSTANTIALLY IN THE SYSTEM SIZE 3.71KW LOCATIONS INDICATED BY THE ILLUSTRATION. MODULE 14 PCS. BEND PM250M01(265W) BUYER: INVERTER 14 PCS. I ENPHASE I M215-60-2LL-S22-IG ROOF TYPE TILE W/COMPOSITE SHINGLE UNDER ARRAY DATE: SUB-ARRAY INFORMATION ARRAY #1 ARRAY#2 ARRAY#3 MOD OTY 10 2 2 BUYER: TILT 23' 23° 23° 90° I DATE: BUILDING AND SAFETY DEPARTMENT PLAN APPROVAL REVIEWED BY ' 46FL H *Approval of these plans shall not be Construed to be r an approval of,any violation of any provisions of the fed!ral,state or cky i regulations and ordinances. This set of approved plai is n ust be kept on the jobsite until completion. SOLADECK WIRE - — TRANSITION BOX (UNDER ARRAY) UTILITY METER 8 MAIN SERVICE PANEL z a2 (VERIFIED BY BUILDER) a PV AC DISCONNECT—,--, EXTERIOR-GARAGE -- - -- -- --- NOTE:DIMENSIONS ARE SHOWN IN PLANE OF ROOF o N PLAN ELEVATION ORIENTATION I LOT# 137 MERIDIAN AT LENNAR: ORIGINAL BY: FREDDY SERNALRUI DATE:14.7.14 980 MONTECITO DRIVE REVIEWED BY:TOM FIDOES DATE:14.7.14 MENIFEE HILLS CORONA,CA 92789 REV# BY DATE I DESCRIPTION Vnciinnasb6 SOLAR DWG TITLE: PAGE#: SCALE: SITE LOCATION: treet INDIVIDUAL 4B Broadway 304 PLOT PLAN I/Ib"=1'-0" 29282 NECTARINE Boulder,1080304 MENIFEE,CA 92584 303.447.0300 SYSTEM LAYOUT - U _ � I U I W i i I _ 1 - I N PLAN 2809 ELEVATION A ORIENTATION I LOT#137 MERIDIAN AT LENNAR: ORIGINAL BY: FREDDY BERNALRUI DATE:14 7-14 980 MONTECITO DRIVE REVIEWED BY:TOM PORES DATE:14,714 MENIFEE HILLS CORONA,CA 92789 REV# BY DATE DESCRIPTION tlmasbd SOLAR DWG TITLE: PAGE#: SCALE: SITE LOCATION: INDIVIDUAL 4571&o,CO83dway 3 R PLOT PLAN 2 1/b4'=1'-0" 29282 NECTARINE ST BO303,4C080304 MENIFEE,CA 92884 303.447.0300 SITE PLAN MODULE SPECS AND CALCULATIONS INVERTER SPECS AND CALCULATIONS ITEM NOTE/CALC UNIT DETAIL ITEM NOTE/CALC UNIT DETAIL LOCATION MENIFEE,CA INV, MAKE INVERTER SPEC ENPHASE TEMP,AMBIENT HIGH(THAR) ASHRAE 2% °C 37 INV. MODEL INVERTER SPEC M215-60-21LL-S22-113 TEMP,AMBIENT LOW(THIN) ASHRAE EXTR.MIN °C -2 INV. MAX POWER,(WAC MAX) INVERTER SPEC WATTS(AO 225 TEMP,MODULE TEST(TTEST) MODULE SPEC °C 25 INV, INPUT V,(VOC MAX) INVERTER SPEC VOLTS 00 48 TEMP,DELTA LOW(TOELTA) THIN-TTEST C -27 INV.OUTPUT V,(VAC NOM) INVERTER SPEC VOLTS(AO 240 MOD. MANUFACTURER MODULE SPEC BEND INV.OUTPUT FREQUENCY INVERTER SPEC HERTZ 60 MOD.PART NUMBER MODULE SPEC PM250MOI INV-OUTPUT CURRENT,IAC INVERTER SPEC AMPS(AC) 0.9 MOD. POWER STC(P) MODULE SPEC WATTS(BC) 265 INV, PHASE QUANTITY INVERTER SPEC PHASE I MOD. OPERATING VOLTAGE(VMP) MODULE SPEC VOLTS(BC) 31.30 COMPLIANCE INVERTER SPEC UL1741/IEEE1547 MOD.OPEN CCT.VOLTAGE(V00 MODULE SPEC VOLTS(DO 38.20 INV. GROUNDING INVERTER SPEC ISOLATED MOD.COEFF. VOLT/TEMP(COEF) MODULE SPEC V/°C $(DC) 8.47 INV.QTY,MAX/BRANCH CCT. INV.QTYBC CITY 14 MOO. MAX VOLTAGE(VMAXMOD) (VOC t(TD-COEFT VOLTS(or) BRANCH CCT.OUTPUT.IHAABC (IAC•INV.OTYBc) AMPS(AC) 12.60 MOD,OPERATING CURRENT(IMP) MODULE SPEC AMPS INV.QUANTITY,TOTAL INV.QTYT CITY MOD.SHORT CCT. CURRENT(I50) MODULE SPEC AMPS TOTAL SYSTEM OUTPUT, WARTS (IAC"INV.QTYT) AMPS(Ac) 12.60 MOD. MAXIMUM CURRENT(IMAX) (ISC " L25) AMPS MIN.AMPACITY RED'D,PER NEC (IMAX' L25) AMPS SERIES FUSE RATING.MAX MODULE SPEC AMPS ELECTRICAL EQUIPMENT SCHEDULE KEY CITY MANUFACTURER MODEL NOTES TRADE 1 14 BEND PM250MOI(265W) PV MODULE SOLAR 2 14 ENPHASE M215-60-2LL-S22-IG PVINVERTER SOLAR 3 3 RSTC/SOLADECK 0786-3R5 PV ROOF JUNCTION BOX,NEMA 3R SOLAR 4 1 CUTLER-HAMMER DG221URB PV AC DISCONNECT,NEMA 3R,240V,30A SOLAR 5 1 ENPHASE ENVOY PV DATA MONITOR, 120V SOLAR 6 1 TBD TBD 120V DEDICATED RECEPTACLE FOR ENVOY PV DATA MONITOR SOLAR 7 1 THD TBD CATS PORT FOR SOLAR PV INTERNET CONNECTION TO HOME NETWORK BOX SOLAR 8 NOTE CUTLER-HAMMER TBD PV BRANCH CIRCUIT BREAKERS;I x 15A-IP(ENVOY) SOLAR 9 NOTE CUTLER-HAMMER TBD PV BREAKER,I x 20A-2P,LOCATE AT OPPOSITE END OF BUS FROM MAIN BREAKER SOLAR 10 1 TBD TBD SERVICE PANEL,MIN. 125A BUS BLDR. ELEC. II 1 1 TBD 1 TBD 1 UTILITY METER. IPH, 120/24OV,200A BLDR. ELEC. 12 1 TBD TBD. GROUNDING ELECTRODE LIFER BLDR- ELEC. CONDUCTOR SIZING CALCULATIONS INTERCONNECTION CALCULATIONS D CONDITION OF USE(COU): F351 MP.DEBATE .FILL DEBATE)VS. REQ'D HMAX) ITEM UNIT PANEL 2)TERMINALS(TERM): RMINALS.vs. RED'0,(IMAX' 1.25) PANEL HER. CUTLER-HAMMER KEY SIZE CU/AL INSULATION CALC. TEMP. RATING AMPS 200 TYPE OERATE DERATE (A) (A) USED(A) MAIN DISCONNECT AMPS 200 A #12 CU THWN-2 COU .76 I'D 22.80 12.60 ALLOWED PV PER NEC AMPS 40 TERM 25157520 PV OCPD DEVICE USED AMPS 20 B #10 CU NM-B COU .91 A 36.40 12.60 TERM 3515.75 20 C 410 CU NM-B COU .91 1.0 36,40 12.60 TERM 1 35 15.95 20 CONDUCTOR SCHEDULE KEY CONDUCTORS CU/AL TYPE LOCATION TRADE A 1 1-#12 ENGAGE CABLE,L#6G,FREE AIR CU I TC-ER ARRAY I SOLAR B 1 3-#10. T#10 EGC CU NM-B(ROMEX) I INTERIOR 11SOLAR C 1 3410, 1-#10 EGC CU NMI(ROMEX) I INTERIOR ISOLAR D CAT5E.ETHERNET CABLE I CU I CAT5E I INTERIOR ISOLAR O © o O O 3 SEE y 10 NOTE IS OWE O OC 30</2P PI IS {_I f�G 12 EXTERIOR-GARAGE ROOF ELECTRICAL DIAGRAM 3.71XW LOT#137 MERIDIAN AT ENNAR: ORIGINAL BY: FREDDY BERNALRUI DATE:14.7.14 980 MONTECITO DRIVE REVIEWED BY:TOM FIDDES I DATE:14.7.14 MENIFEE HILLS CORONA,CA 92789 REV.# HY DATE DESCRIPTION namaste SOLAR DWG TITLE: PAGE#: SCALE: SITE LOCATION: INDIVIDUAL 4Bo Broadway CO 8Street PLOT PLAN 3 NITS 29282 NECTARINE ST Boulder, 70 80304 MENIFEE,CA 92584 303.44].0300 ELECTRICAL STRUCTURAL NOTES: SOLAR CONTRACTOR- S ALL PV ROOF ATTACHMENTS WILL BE SPACED ALONG MODULE RACKING RAILS AT NOT GREATER THAN 48-O.C. 2)ALL PV ROOF ATTACHMENTS WILL BE STAGGERED BY ROW AMONGST THE ROOF FRAMING MEMBERS,TO MAXIMUM EXTENT POSSIBLE. 3)ROOF PENETRATIONS ASSOCIATED WITH SOLAR RACKING WILL BE SEALED WITH AN APPROVED SEALANT. 4)SOLADECK WIRE TRANSITION BOX WILL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS. IT WILL BE FLASHED AND SEALED. 5)PV ARRAY WILL BE A MINIMUM OF 3-ABOVE THE COMPOSITE SHINGLE ROOF SURFACE. 6)THE UNIRAC SOLARMOUNT RACKING SYSTEM AND SOLAR PV ARRAY WILL BE INSTALLED ACCORDING TO THE UNIRAC SOLARMOUNT CODE-COMPLIANT INSTALLATION MANUAL,VERSION 227.3.PUB 140II3-ICC,JANUARY 2014. 7)UNIRAC TOP CLAMPS REQUIRE A ONE INCH(I")SPACE BETWEEN PV MODULES SOLARMOUNT RAILS MUST EXTEND A MINIMUM OF TWO INCHES(21 BEYOND THE EDGE OF THE PV ARRAY/SUB-ARRAY. 8)UNIRAC SOLARMOUNT REQUIRES THAT A THERMAL EXPANSION GAP BE INSTALLED FOR ANY RAIL LENGTH OF GREATER THAN 40'. ROOFING CONTRACTOR- 1)DISTANCE BETWEEN ARRAY EDGE AND TRANSITION FLASHING(COMPOSITION TO TILE)WILL BE A MINIMUM OF 3'. 2)26 GAUGE INTERLOCKING FLASHING"SIDEWALC TO BE INSTALLED ALONG THE LENGTH OF THE PV ARRAY AT ROOFING MATERIAL TRANSITION. IT SHALL BE APROVED PRIOR TO PV SYSTEM INSTALLATION. 3)PEEL-N-STICK BASE TO BE INSTALLED ONE FOOT 01 OR MORE BEYOND THE EDGE OF THE COMPOSITION SHINGLE,DOWN TO THE ROOF EAVE. PEEL-N-STICK BASE TO BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS. 4)AREAS UNDER EACH PV ARRAY SHALL BE ROOFED WITH COMPOSITION SHINGLE.COMPOSITION SHINGLE SHALL RUN FROM ABOVE THE PV ARRAY TO THE ROOF EAVE. 5)TILE INSTALLED BELOW THE ARRAY TO BE INSTALLED ABOVE THE COMPOSITION ROOF PER ROOFER SPECIFICATIONS. 6)BIRDSTOP WILL BE INSTALLED AT THE UPPERMOST TRANSITION FROM TILE TO COMPOSITION SHINGLE. BIRDSTOP TO BE SPECIFIED BY ROOFER PRIOR TO INSTALLATION. ELECTRICAL NOTES: GENERAL- [)ALL PV EQUIPMENT WILL BE TESTED AND LISTED FOR ITS USE BY A NATIONALLY RECOGNIZED TESTING LABORATORY(NRTL). 2)THE GROUNDING OF THE PHOTOVOLTAIC SYSTEM SHALL COMPLY WITH THE APPLICABLE VERSION OF THE NEC/CEC. 3)ALL GROUNDING ELECTRODE CONDUCTORS WILL BE INSTALLED IN A CONTINUOUS LENGTH EXCEPT WHERE SPLICED BY AN IRREVERSIBLE CONNECTOR OR EXOTHERMIC WELD. 4)NON-CURRENT CARRYING METAL PARTS SHALL BE CHECKED FOR PROPER GROUNDING,NOTING THAT TERMINAL LUGS BOLTED ON AN ENCLOSURE'S FINISHED SURFACE MAY BE ELECTRICALLY INSULATED BECAUSE OF PAINT/FINISH. PAINT/FINISH AT POINT OF CONTACT SHALL BE PROPERLY REMOVED. 5)ROOF PENETRATIONS WILL BE COMPLETED AND SEALED PER APPLICABLE CODE. 6)ALL CONDUCTORS WILL HAVE A 90-C RATING TO ENSURE CODE COMPLIANCE. SOLAR CONTRACTOR- 7)MODULE CERTIFICATIONS WILL INCLUDE UL1703, IEC61646. IEC61730. 8)CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS. 9)RACEWAY POINT OF PENETRATION FROM EXTERIOR TO INTERIOR WILL BE SEALED TO PREVENT INGRESS OF WATER AND INSECTS. 10)DC WIRING IS LIMITED TO PV ARRAY FOOTPRINT W/ENPHASE MICRO-INVERTER SYSTEM. 11)MODULE AND ENPHASE WIRING SHALL BE LOCATED AND SECURED UNDER THE ARRAY USING SUITABLE WIRING CLIPS.WIRING SHALL NOT MAKE CONTACT WITH THE ROOF SURFACE AND SHALL BE MANAGED IN A WORKMAN-LIKE MANNER. 12)EQUIPMENT GROUNDING CONDUCTORS WILL BE SIZED IN ACCORDANCE WITH NEC TABLE 250.122. 13)CONDUCTOR TERMINATIONS WILL BE TORQUED PER DEVICE LISTING,OR MANUFACTURER'S RECOMMENDATIONS. 14)A PV AGGREGATION PANEL(SUB PANEL)WILL NOT BE INCLUDED FOR SYSTEMS WITH ONE BRANCH CIRCUIT. 15)A DEDICATED 120V BRANCH CIRCUIT IS REQUIRED IN MASTER CLOSET(OR EQUIVALENT)FOR ENPHASE ENVOY MONITOR. SIGNAGE- 16)PV SYSTEMS SHALL BE CLEARLY MARKED IN ACCORDANCE WITH NEC ARTICLE 690 AND OTHER APPLICABLE STATE AND LOCAL CODES. 17)ALL SAFETY MARKING /PLACARDS SHALL BE PERMANENTLY ATTACHED BY ADHESIVE OR OTHER MECHANICAL MEANS. 18)MARKING /PLACARDS WILL BE METAL OR PLASTIC WITH ENGRAVED OR MACHINE PRINTED LETTERING.BACKGROUND WILL BE RED WITH WHITE CAPITAL LETTERING OF MINIMUM HEIGHT 13 19)ALL WIRING/RACEWAYS/JUNCTION BOXES WILL BE MARKED"PHOTOVOLTAIC POWER SOURCE,"OR EQUIVALENT;WIRING7RACEWAYS SHALL BE MARKED EVERY 10'. BUILDER ELECTRICAL AND SOLAR CONTRACTORS- 20)INSTALLATION SHALL BE COMPLETED IN A NEAT AND WORKMAN-LIKE MANNER. 21)SPACE REQUIREMENTS FOR ALL ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110.26. ORIGINAL BY: FREDDY BERNALRUI tDATE:14.7.14 MERIDIAN AT LENNAR: REVIEWED BY TOM FIDDEB DATE:14.7.14 CORONA,RONA,CA 92789 MENIFEE HILLS CO ECITO DRIVE REV.# BY DATE DESCRIPTION Vnamasbd ..IA[ DWG TITLE: PAGE It: SCALE: SITE LOCATION: 4571 BroadwayGO13 Street 29282 NECTARINE BT Boulder,C080304 PLOT PLAN 4 NTS MENIFEE,CA 9258 W ,4 30344].0300 NOTES CAUTION: POWER TO THIS BUILDING IS SUPPLIED BY THE UTILITY AND A SOLAR PV SYSTEM. DISCONNECTS ARE LOCATED AS SHOWN. SOLADECK WIRE TRANSITION BOX (UNDER ARRAY) UTILITY METER e MAIN SERVICE PANEL (VERIFIED BY BUILDER) PV AC DISCONNECT EXTERIOR-GARAGE T. . SERVICE BY QUALIFIED PERSONNEL ONLY CONTACT: SUNSTREET ENERGY GROUP 1-877-SLR-POWR NOTE: SEE MASTER SET FOR ADDITIONAL PLACARD INFORMATION MERIDIAN AT LENNAR: ORIGINAL BY: FREDDY BERNALRUI DATE 14 7.14 980 MONTECITO DRIVE REVIEWED BY:TOM FIDDES I DATE:14.7.14 MENIFEE HILLS CORONA,CA 92789 REV.# BY DATE DESCRIPTION Vncimasrd f OIA! DWG TITLE: PAGE#: SCALE: SITE LOCATION: INDIVIDUAL 4571 Broadway 3M PLOT PLAN 5 NTS treet 29282 NECTARINE ST BOUi CO 800.1 MENIFEE,CA 92584 3014470300 PLACARDS