Loading...
PMT14-02124 City of Menifee Permit No.: PMT14-02124 29714 HAUN RD. Type: Residential Electrical ' ' GC'-4.,�i.` MENIFEE, CA 92586 sm s.nm,�r MENIFEE Date Issued: 0 8/1 812 01 4 s PERMIT Site Address: 29306 NECTARINE ST, MENIFEE, CA Parcel Number: 333-621-001 92584 Construction Cost: $8,017.20 Existing Use: Proposed Use; Description of SOLAR- 12 PANELS 3.18 KW LOT 135 Work: MASTER PLAN PMT14-00706 TR 31582-1 Owner Contractor LENNAR HOMES LENNAR HOMES OF CALIFORNIA INC 980 MONTECITO DR#302 25 ENTERPRISE CORONA, CA 92879 ALISO VIEJO, CA 92656 Applicant Phone: 9493498000 JEREMIAH ACAYTURRI License Number: 728102 25 ENTERPRISE ALISO VIEJO, CA 92656 Fee Description (3ty Amount Building Permit Issuance 1 27.00 SMIP RESIDENTIAL 1 2.00 $282.00 The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and specifications or from preventing building operations being carried on thereunder when in violation of the Building Code or of any other ordinance of City of Menifee. Except as otherwise stated,a permit for construction under which no work is commenced within six months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be forfeited. AA_Bldg_Permit_Template.rpt Page 1 of 1 CITY OF M1UNllFEE PLCK No: P It14 A aq 29714 Haun Road Date: Date: v Menifee, CA 92586 6115H Phone: (951)672-6777 Amount: JAmount: Fax:(951)679-3843 Ck#: k#: G1 / Building Combination Permit "J pkase 3Mertol►ah To Be Completed By Applicant Legal Description: Menifee Hills/ El Dorado T31582-1 I Planning Case: F: L: Rt: R: Property Address: Lot 135 29306 Nectarine St Assessor's Parcel Number. 333 621 001 ProjectfTenant Name: Unit#: Floor III T 31582-1 - Menifee Hills - Meridian Name: Lennar Homes of California, Inc Phone NM1-817-3680 IFax No. Property Address: Unit Number Zip Code 9 Owner 980 Montecito Dr., Suite 302 Corona CA Email Address: , eremiah.aca urri lennar.com Name: Phone No. Fax No. Jeremiah Acayturri 951-403-3715 Applicant Address: same as above Unit Number Zip Code Email Address: jeremiah.acayturri@lennar.com Name: Phone No. Fax No. Contractor Address: Ciry State Zip Code Contractor's City Business License o. Contractor's City State of California License Na_ Classification: B Number of Squares: Square Footage 3.18 kW/ 12 PCS / 12 PCS Description of Work: Solar PjaD 2033 Elevation A costof Work:$8017.20 Applicants Signature Date: 7/25/2014 To. ompleted By City Staff Only. ate As R-Received or N/A-Not Applicable 5 Completes sets of fully dim caned,drawn to sale plans Wf5ich include: 1 set of documents which Include ❑ Title Sheet ❑ Elevations ❑ Electrical Plan ❑ Goo Tech/Soils Report(on cd only) ❑ Plot/Site Plan ❑ Roof Plan ❑ Mechanical Plan ❑ Title 24 Energy(on 8'/,x 11) ❑❑ Foundation Plan ❑ Cross Section ❑ Plumbing Plan Structural Calculations ❑ Single Line diagram for elec.services over 400 AMP ❑ Floor Plan ❑ Structural Framing Plan&Details ❑ Shoring Plan ❑ Sound Report-Residential Class Code: Indicate New Construction Alteration* Addition* MeanslMethods Work Type: Repair* Retrofit* ReNsion to Existing Permit'IRequired? YES NO Proposed Building Use(s): Existing Building Use(s): #Buildings: #Units: It Stories: Will the Building Have a Basement? Y of N Bldg.Code Occupancy Group Indicate Indicate if YES or NO Indicate all Geo-tech.Haz.Zone At Project Construction Sprinklered that apply: Coastal Zone Completion: Type(s): C Of O YES or NO Noise Zone Required? Listed on Historic Resources Inventory CITY PLANNING STAFF ONLY APPROVALS: Costal Commis Arch.Review Board Landmark Comm. Planning Comm.Zoning Administrator Fee Exempt: City Project Elec.Vehicle Charger Landmark Seismic Retrofit special case:emg. Orfid.'lA ,oval Expedite Project(s): Child Care City Project Green Building Landmark Affordable Housing For Staff Use Only Bullding/Safety I Permit Specialist City Planning ICivil Engineering EPWM-Admin Transportation Mgmt. Rent Control THANK YOU FOR HELPING US CREATE A BETTER COMMUNITY SYSTEM INFORMATION BUYER ACKNOWLEDGES THAT THE SOLAR MODULES TO BE INSTALLED ITEM OTY PER. MODEL ON THE ROOF OF THE HOME WILL BE SUBSTANTIALLY IN THE SYSTEM SIZE 3.ISKW LOCATIONS INDICATED BY THE ILLUSTRATION. MODULE 12 PCS. I BEND I PM250MOI(265W) BUYER: INVERTER 1 12 PCS JENPHASE I M215-60-2LL-S22-IG ROOF TYPE I TILE W/COMPOSITE SHINGLE UNDER ARRAY DATE: SUB-ARRAY INFORMATION ARRAY#I ARRAY#2 ARRAY#3 MOD OTY 12 N/A N/A BUYER: —__-----__--- TILT 1 23° 1 N/A N/A AZIMUTH 270° N/A N/A DATE: CITY OF MENIFEE BUILDING AND SAFETY DEPARTMENT PLAN APPROVAL 10 3 REVIEWED BY - - - - -- - DATE SOLADECK WIRE III TRANSITION BOX 'Approval of thesdolam sftatl Eto be con rue to be a per it r,or an approval of,any violation of any pr visio Ilof t e federal, a or city regulations and ordinances. This set f a ans mu b kept on the jobsite until completion. i i UTILITY METER 8 MAIN SERVICE PANEL (VERIFIED BY BUILDER) PV AC DISCONNECT - EXTERIOR-GARAGE 1 O NOTE:DIMENSIONS ARE SHOWN IN PLANE OF ROOF N PLAN 2033 ELEVATION A ORIENTATION I LOT#135 MERIDIAN AT LENNAR- ORIGINAL BY: FREDDY BERNALRUI DATE:14.7.14 980 MONTECITO DRIVE REVIEWED BY:TOM FIDDES DATE:14.T 14 MENIFEE HILLS CORONA,CA 92789 REV.# BY DATE DESCRIPTION Vn(3mc3srd DWG TITLE: PAGE#: SCALE: soiAe SITE LOCATION: 4571 Broadway, 3N INDIVIDUAL 29306 NECTARINE ST Boulder,COC O30804 PLOT PLAN I/16"=1'-0" MENIFEE.CA 92584 30344]0300 SYSTEM LAYOUT I I -- ti 1316 Z W Q ti W 77 PLAN 2033 ELEVATION A ORIENTATION I LOT#135 MERIDIAN AT ENNAR: ORIGINAL BY: FREDDY BERNALRUI DATE:14.7.14 980 MONTECITO DRIVE REVIEWED BY:TOM FIDOES DATE:14J 14 MENIFEE HILLS CORONA,CA 92789 REV.# BY DATE DESCRIPTION VmmastI6 aoue DWG TITLE: PAGE#: SCALE: SITE LOCATION: INDIVIDUAL 4Bo Broadway.,,GO8Street PLOT PLAN 2 1/04'W-0' MENIF NECTARINE ST Bo303, 708O3OA MENIFEE CA 92584 303417.0300 SITE PLAN MODULE SPECS AND CALCULATIONS INVERTER SPECS AND CALCULATIONS ITEM NOTE/CALC UNIT DETAIL ITEM NOTE/CALC UNIT DETAIL LOCATION MENIFEE,CA INV. MAKE INVERTER SPEC ENPHASE TEMP,AMBIENT HIGH(TMAX) ASHRAE 2% °C 37 INV, MODEL INVERTER SPEC M215-60-2LL-S22-IG 1 TEMP,AMBIENT LOW(TMIN) ASHRAE EXTR.MIN "C -2 INV. MAX POWER,(WAC MAX) INVERTER SPEC WATTS(AC) 225 TEMP,MODULE TEST(TTEST) MODULE SPEC °C 25 INV. INPUT V.(VDC MAX) INVERTER SPEC VOLTS(Do) 48 TEMP,DELTA LOW(TDEETA) TMIN-TTEST °C -27 INV. OUTPUT V.(VAc MOM) INVERTER SPEC VOLTS(Ad 240 MOD, MANUFACTURER MODULE SPEC BEND INV.OUTPUT FREQUENCY INVERTER SPEC HERTZ 60 MOD.PART NUMBER MODULE SPEC PM250MOI INV.OUTPUT CURRENT, IAD INVERTER SPEC AMPS(AC) 0.9 MOD.POWER STC(P) MODULE SPEC WATTS(DC) 265 INV. PHASE QUANTITY INVERTER SPEC PHASE I MOD.OPERATING VOLTAGE(VMP) MODULE SPEC VOLTS(DC) 31,30 COMPLIANCE INVERTER SPEC UL174I/IEEE1547 MOD.OPEN CCT. VOLTAGE(Vac) MODULE SPEC VOLTS(Dc) 38.20 INV. GROUNDING INVERTER SPEC ISOLATED MOD. COEFF. VOLT/TEMP(COEF) MODULE SPEC V/°C -0 115 INV. OTY,MAX/BRANCH CCT. INV.OTYBC OTY 12 MOD. MAX VOLTAGE(VMA%MOD) (Vac�(TD'COEF)) VOLTS(Dc) 41.31 BRANCH CCT. OUTPUT,IMAxaC (IAC'1NV.OTYBC) I AMPS CAC) 1 10.80 MOD. OPERATING CURRENT(IMP) MODULE SPEC AMPS(DC) 8.47 INV. QUANTITY,TOTAL INV.QTYT QTY 1 12 MOD.SHORT CCT. CURRENT(Isc) MODULE SPEC AMPS(DD) 8.98 TOTAL SYSTEM OUTPUT,IMAXTS (IACINV.QTYT) AMPS(AC) 10.80 MOD. MAXIMUM CURRENT OMAx) (Isc' 1.25) AMPS(DC) 11.25 MIN.AMPACITY RED'D.PER NEC (IMAX- 1.25) AMPS(DO 14,03 SERIES FUSE RATING,MAX MODULE SPEC AMPS(DC) 15 ELECTRICAL EQUIPMENT SCHEDULE KEY QTY MANUFACTURER MODEL NOTES TRADE 1 12 BERG PM250MOI(265W) PV MODULE SOLAR 2 12 ENPHASE M215-60-2LL-S22-IG PVINVERTER SOLAR 3 1 RSTC/SOLADECK 0786-3R5 PV ROOF JUNCTION BOX,NEMA 3R SOLAR 4 1 CUTLER-HAMMER DG221URS PV AC DISCONNECT,NEMA 3R,240V,30A SOLAR 5 1 ENPHASE ENVOY PV DATA MONITOR, 120V SOLAR 6 1 TBD TBD 120V DEDICATED RECEPTACLE FOR ENVOY PV DATA MONITOR SOLAR 7 1 TBD TBD CATS PORT FOR SOLAR PV INTERNET CONNECTION TO HOME NETWORK BOX SOLAR 8 NOTE CUTLER-HAMMER TBD PV BRANCH CIRCUIT BREAKERS;I x 15A-IP(ENVOY) SOLAR. 9 NOTE CUTLER-HAMMER TBD PV BREAKER, I x 20A-2P.LOCATE AT OPPOSITE END OF BUS FROM MAIN BREAKER SOLAR 10 I TBD TBD SERVICE PANEL,MIN. 125A BUS BLDR. ELFC. II TBD TBD UTILITY METER, IPH, 120/24OV,200A BLDR ELEC. 12 TBD I TBD GROUNDING ELECTRODE UFER BLDR. ELEC. CONDUCTOR SIZING CALCULATIONS INTERCONNECTION CALCULATIONS 1)CONDITION OF USE(COLD: (AMPACITY'TEMP.DERATE-FILL DERATE)vs.REO'D HMAX) ITEM UNIT I PANEL 2)TERMINALS(TERM): AMPACITY AT TERMINALS.VS. REQ'D,([MAX` 1.25) PANEL MFR. CUTLER-HAMMER KEY SIZE CU/ALVINSULATIONCALC. AMPACITY W/O TEMP. 00 TYPE DEBATES DERATE DERATE (A) (A) USED(A) MAIN DISCONNECT AMPS 200 A #12 CU COU 3016 1.0 22.80 10.80 ALLOWED PV PER NEC AMPS 40TERM 25 25 13.50 20 PV OCPD DEVICE USED AMPS 20B #10 CU COU 40911.0 36.40 10.80TERM 35 35 13.50 20 #10 CU. COU 40 .91 1.0 36.40 10.BO TERM 35 35 13.50 20 CONDUCTOR SCHEDULE KEY I CONDUCTORS 1 CU/AL 1 TYPE LOCATION TRADE q 1 1-#12 ENGAGE CABLE, 1-#6G,FREE AIR I CU TC-ER ARRAY SOLAR B 3-#10,1-#10 EGG I CU NM-B(ROMEX) INTERIOR I SOLAR C 3-#10,1-#10 EGC CU NM-B(ROMEX) I INTERIOR I SOLAR D CAT5E.ETHERNET CABLE CU CAT5E INTERIOR I SOLAR © 5 D _ O • f • 7 SEE 0 NOTE I5 OISA/IP 9 -1 O O 8 3 M® A II G G G 12 I I I EXTERIOR-GARAGE ROOF ELECTRICAL DIAGRAM 3.IBKW LOT#135 MERIDIAN AT ENNAR: ORIGINAL BY: FREDDY BERNALRUI DATE:14.7.14 980 NONTECITD DRIVE REVIEWED BY:TOM FIDDES DATE:14-7,14 MENIFEE HILLS CORONA,CA 92789 REV.# BY DATE DESCRIPTION namasbi& aouv DWG TITLE: PAGE it: SCALE: SITE LOCATION: INDIVIDUAL 4Bo Broadway GO 8Street PLOT PLAN 3 NTS 29306 NECTARINE ST Boulder, 7, 80304 MENIFEE,CA 92584 303.447.0300 ELECTRICAL STRUCTURAL NOTES: SOLAR CONTRACTOR- 1)ALL PV ROOF ATTACHMENTS WILL BE SPACED ALONG MODULE RACKING RAILS AT NOT GREATER THAN 48'O.C. 2)ALL PV ROOF ATTACHMENTS WILL BE STAGGERED BY ROW AMONGST THE ROOF FRAMING MEMBERS,TO MAXIMUM EXTENT POSSIBLE. 3)ROOF PENETRATIONS ASSOCIATED WITH SOLAR RACKING WILL BE SEALED WITH AN APPROVED SEALANT. 4)SOLADECK WIRE TRANSITION BOX WILL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS. IT WILL BE FLASHED AND SEALED. 5)PV ARRAY WILL BE A MINIMUM OF 3'ABOVE THE COMPOSITE SHINGLE ROOF SURFACE. 6)THE UNIRAC SOLARMOUNT RACKING SYSTEM AND SOLAR PV ARRAY WILL BE INSTALLED ACCORDING TO THE UNIRAC SOLARMOUNT CODE-COMPLIANT INSTALLATION MANUAL,VERSION 227.3,PUB 11.0113-ICC,JANUARY 20(4. 7)UNIRAC TOP CLAMPS REQUIRE A ONE INCH(I)SPACE BETWEEN PV MODULES. SOLARMOUNT RAILS MUST EXTEND A MINIMUM OF TWO INCHES(Z")BEYOND THE EDGE OF THE PV ARRAY/SUB-ARRAY. 8)UNIRAC SOLARMOUNT REQUIRES THAT A THERMAL EXPANSION GAP BE INSTALLED FOR ANY RAIL LENGTH OF GREATER THAN 40. ROOFING CONTRACTOR- U DISTANCE BETWEEN ARRAY EDGE AND TRANSITION FLASHING(COMPOSITION TO TILE)WILL BE A MINIMUM OF 3'. 2)26 GAUGE INTERLOCKING FLASHING 'SIDEWALL'TO BE INSTALLED ALONG THE LENGTH OF THE PV ARRAY AT ROOFING MATERIAL TRANSITION. IT SMALL BE APROVED PRIOR TO PV SYSTEM INSTALLATION. 3)PEEL-N-STICK BASE TO BE INSTALLED ONE FOOT(19 OR MORE BEYOND THE EDGE OF THE COMPOSITION SHINGLE,DOWN TO THE ROOF EAVE. PEEL-N-STICK BASE TO BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS. 4)AREAS UNDER EACH PV ARRAY SHALL BE ROOFED WITH COMPOSITION SHINGLE.COMPOSITION SHINGLE SHALL RUN FROM ABOVE THE PV ARRAY TO THE ROOF EAVE. 5)TILE INSTALLED BELOW THE ARRAY TO BE INSTALLED ABOVE THE COMPOSITION ROOF PER ROOFER SPECIFICATIONS. 6)BIRDSTOP WILL BE INSTALLED AT THE UPPERMOST TRANSITION FROM TILE TO COMPOSITION SHINGLE. BIRDSTOP TO BE SPECIFIED BY ROOFER PRIOR TO INSTALLATION. ELECTRICAL NOTES: GENERAL 1)ALL PV EQUIPMENT WILL BE TESTED AND LISTED FOR ITS USE BY A NATIONALLY RECOGNIZED TESTING LABORATORY(NRTL). 2)THE GROUNDING OF THE PHOTOVOLTAIC SYSTEM SHALL COMPLY WITH THE APPLICABLE VERSION OF THE NEC/CEC. 3)ALL GROUNDING ELECTRODE CONDUCTORS WILL BE INSTALLED IN A CONTINUOUS LENGTH EXCEPT WHERE SPLICED BY AN IRREVERSIBLE CONNECTOR OR EXOTHERMIC WELD. 4)NON-CURRENT CARRYING METAL PARTS SHALL BE CHECKED FOR PROPER GROUNDING,NOTING THAT TERMINAL LUGS BOLTED ON AN ENCLOSURE'S FINISHED SURFACE MAY BE ELECTRICALLY INSULATED BECAUSE OF PAINT/FINISH. PAINT/FINISH AT POINT OF CONTACT SHALL BE PROPERLY REMOVED. 5)ROOF PENETRATIONS WILL BE COMPLETED AND SEALED PER APPLICABLE CODE. 6)ALL CONDUCTORS WILL HAVE A 90°GRATING TO ENSURE CODE COMPLIANCE. SOLAR CONTRACTOR- 7)MODULE CERTIFICATIONS WILL INCLUDE UL1703. IEC61646, IEC61730. 8)CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS. 9)RACEWAY POINT OF PENETRATION FROM EXTERIOR TO INTERIOR WILL BE SEALED TO PREVENT INGRESS OF WATER AND INSECTS. 10)DC WIRING IS LIMITED TO PV ARRAY FOOTPRINT W/ENPHASE MICRO-INVERTER SYSTEM. 11)MODULE AND ENPHASE WIRING SHALL BE LOCATED AND SECURED UNDER THE ARRAY USING SUITABLE WIRING CLIPS.WIRING SHALL NOT MAKE CONTACT WITH THE ROOF SURFACE AND SHALL BE MANAGED IN A WORKMAN-LIKE MANNER. 12)EQUIPMENT GROUNDING CONDUCTORS WILL BE SIZED IN ACCORDANCE WITH NEC TABLE 250.122. 13)CONDUCTOR TERMINATIONS WILL BE TORQUED PER DEVICE LISTING,OR MANUFACTURER'S RECOMMENDATIONS. 14)A PV AGGREGATION PANEL(SUB PANEL)WILL NOT BE INCLUDED FOR SYSTEMS WITH ONE BRANCH CIRCUIT. 15)A DEDICATED 120V BRANCH CIRCUIT IS REQUIRED IN MASTER CLOSET(OR EQUIVALENT)FOR ENPHASE ENVOY MONITOR. SIGNAGE- 16)PV SYSTEMS SHALL BE CLEARLY MARKED IN ACCORDANCE WITH NEC ARTICLE 690 AND OTHER APPLICABLE STATE AND LOCAL CODES. 17)ALL SAFETY MARKING /PLACARDS SHALL BE PERMANENTLY ATTACHED BY ADHESIVE OR OTHER MECHANICAL MEANS. 18)MARKING /PLACARDS WILL BE METAL OR PLASTIC WITH ENGRAVED OR MACHINE PRINTED LETTERING.BACKGROUND WILL BE RED WITH WHITE CAPITAL LETTERING OF MINIMUM HEIGHT J. 19)ALL WIRING/RACEWAYS7JUNCTION BOXES WILL BE MARKED'PHOTOVOLTAIC POWER SOURCE;OR EQUIVALENT;WIRING/RACEWAYS SHALL BE MARKED EVERY 10'. BUILDER ELECTRICAL AND SOLAR CONTRACTORS- 70)INSTALLATION SHALL BE COMPLETED IN A NEAT AND WORKMAN-LIKE MANNER - 21)SPACE REQUIREMENTS FOR ALL ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110.26. MERIDIAN AT LENNAR: ORIGINAL BY: FREDDY BERNALRUI DATE 14.7.14 980 MONTECITO DRIVE REVIEWED BY:TOM FIDDES DATE:14.7J4 MENIFEE HILLS CORONA,CA 92789 REV.# BY DATE DESCRIPTION rlamasGB SOLAR DWG TITLE: PAGE#: SCALE: SITE LOCATION: 4571 Broadway Street INDIVIDUAL 29306 NECTARINE ST Boultler,CO WON PLOT PLAN 4 NTS MENIFEE,CA 92584 303447.03W NOTES CAUTION: POWER TO THIS BUILDING IS SUPPLIED BY THE UTILITY AND A SOLAR PV SYSTEM. DISCONNECTS ARE LOCATED AS SHOWN. SOLADECK WIRE TRANSITION BOX (UNDER ARRAY) VN UTILITY METER 8 MAIN SERVICE PANEL (VERIFIED BY BUILDER) PV AC DISCONNECT EXTERIOR-GARAGE SERVICE BY QUALIFIED PERSONNEL ONLY CONTACT: SUNSTREET ENERGY GROUP 1-877-SLR-POWR NOTE: SEE MASTER SET FOR ADDITIONAL PLACARD INFORMATION MERIDIAN AT LENNAR: ORIGINAL BY: FREDDY BERNALRUI DATE:14.7.14 980 MONTECITO DRIVE REVIEWED BY:TOM FIDDES I DATE:14 T14 MENIFEE HILLS CORONA,CA 92789 REV.# BY DATE DESCRIPTION Vnamast;d aoue DWG TITLE: PAGE#: SCALE: SITE LOCATION: INDIVIDUAL 4571 Be,.DO 8Street PLOT PLAN 5 NTS 29N6 NECTARINE ST BO303 CO3M PLACARDS MENIFEE,CA 92584 30344]0300