PMT14-02121 City of Menifee Permit No.: PMT14-02121
29714 HAUN RD, Type: Residential Electrical
'V=EL MENIFEE, CA 92586
MENIFEE Datelssued: 08/18/2014
I
PERMIT
Site Address: 29297 NECTARINE ST, MENIFEE, CA Parcel Number: 333-624-018
92584 Construction Cost: $9,353.40 '
Existing Use: Proposed Use:
Description of SOLAR- 14 PANELS 3.7 KW LOT 132
Work: MASTER PLAN PMT14-00706
TR 31582-1
Owner Contractor
LENNAR HOMES LENNAR HOMES OF CALIFORNIA INC
980 MONTECITO DR#302 25 ENTERPRISE
CORONA, CA 92879 ALISO VIEJO, CA 92656
Applicant Phone: 9493498000
JEREMIAH ACAYTURRI License Number: 728102
25 ENTERPRISE
ALISO VIEJO, CA 92656
Fee Description Qtv Amount
LSolar Resfdentlal-o aSmall Comm�rglalt '` 29'0
Building Permit Issuance 1 27.00
GRE FEE y0,.
SMIP RESIDENTIAL 1 2.00
$282.00
The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and
specifications or from preventing builiding operations being carried on thereunder when in violation of the Building Code or of any other
ordinance of City of Menifee. Except as otherwise stated,a permit for construction under which no work is commenced within six
months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be
forfeited.
AA_Pdg_Permlt_Template.rpt Page 1 of 1
City Of Menifee
LICENSED DECLARATION
I hereby affirm under penalty or perjury that I am licensed under provisions of ❑ I, as owner of the property an exclusively contracting with licensed
Chapter 9 (commencing with section 7000)of Division 3 of the Business and contractors to construct the project(Section 7044, Business and Professions
Professions Code and my license is in full force and effect. Code:The Contractor's License Law does not apply to an owner of a property
License Class License No. who builds or improves thereon, and who contracts for the projects with a
Expires Signature licensed contractor(s)pursuant to the Contractors State License Law).
WORKERS'COMPENSATION DECLARATION
❑ I am exempt from Iicensure under the Contractors'State License Law for the
❑ I hereby affirm under penalty of perjury one of the following declarations: following reason:
I have and will maintain a certificate of consent of self-insure for workers' By my signature below I acknowledge that, except for my personal residence in
compensation,issued by the Director of Industrial Relations as provided for by which I must have resided for at least one year prior to completion of
Section 3700 of the Labor Code, for the performance of work for which this improvements covered by this permit, I cannot legally sell a structure that I have
permit is issued.
Policy# built as an owner-building if it has not been constructed in its entirety by licensed
contractors. I understand that a copy of the applicable law, Section 7044 of the
❑ I have and will maintain workers' compensation insurance, as required by Business and Professions Code,is available upon request when this application is
section 3700 of the Labor Code, for the performance of the work for which this submitted or at the following Web site:http'//www,leciinfo.ca.gov/calaw.html.
permit is issued.My workers'compensation insurance carrier and policy number are:
Carrier Property Owner or Authorized Agent Date
Expires Policy#
❑ By my Signature below, I certify to each of the following: I am the properly
Name of Agent Phone# owner or authorized to act on the property owner's behalf. I have read this
(This section need not be completed if the permit is for application and the information I have provided is correct. I agree to comply
one-hundred dollars($100)or less) with all applicable city and county ordinances and state laws relating to building
construction.I authorize representatives of this city or county to enter the above-
. ❑ I certify that in the performance of the work for which this permit is issued,I identified property for the inspection purposes.
shall not employ any persons in any manner so as to become subject to the
workers' compensation laws of California, and agree that if I should become
subject to the workers'compensation provisions of Section 3700 of the Labor property Owner or Authorized Agent Date
Code,I shall forthwith comply with those provisions.
City Business License#
Date; Applicant;
WARNING: FAILURE TO SECURE WORKERS' HAZARDOUS MATERIAL DECLARATION
COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL
SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND
CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS WILL THE APPLICANT OR FUTURE BUILDING
($100,000), IN ADDITION TO THE COST OF COMPENSATION, AYES OCCUPANT HANDLE A HAZARDOUS MATERIAL ORA
DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE MIXTURE CONTAINING A HAZARDOUS MATERIAL
LABOR CODE, INTEREST,AND ATTORNEYS FEES ❑NO EQUAL TO OR GREATER THAN THE AMOUNTS
CONSTRUCTION LENDING AGENCY SPECIFIED ON THE HAZARDOUS MATERIALS
I hereby affirm that under the penalty of perjury there is a construction lending INFORMATION GUIDE?
agency for the performance of the work which this permit is issued (Section WILL THE INTENDED USE OF THE BUILDING BY THE
3097 Civil Code) APPLICANT OR FUTURE BUILDING OCCUPANT REQUIRE
Lender's Name ❑YES A PERMIT FOR THE CONSTRUCTION OR MODIFICATION
FROM THE SOUTH COAST AIR QUALITY MANAGEMENT
Lender's Address ❑NO DISTRICT(SCAQMD) SEE PERMITTING CHECKLIST FOR
OWNER BUILDER DECLARATIONS GUIDE LINES
I hereby affirm under penalty of perjury that I am exempt from the Contractor's PRINT NAME:
License Law for the reason(s)indicated below by the checkmark(s)I have placed ❑YES WILL THE PROPOSED BUILDING OR MODIFIED FACILITY
next to the applicable item(s)(Section 7031.5. Business and Professions Code: BE WITHIN 1000 FEET OF THE OUTER BOUNDARY OF A
Any city or county that requires a permit to construct, alter, improve, demolish, D NO SCHOOL?
or repair any structure, prior to its issuance, also requires the applicant for the
permit to file a signed statement that he or she is licensed pursuant to the
provisions of the Contractor's State License Law(Chapter 9 (commencing with I HAVE READ THE HAZARDOUS MATERIAL
Section 7000)of Division 3 of the Business and Professions Code)or that he or ❑YES INFORMATION GUIDE AND THE SCAQMD PERMITTING
she is exempt from licensors and the basis for the alleged exemption. Any CHECKLIST. I UNDERSTAND MY REQUIREMENTS
violation of Section 7031.5 by any Applicant for a permit subjects the applicant to ❑NO UNDER THE STATE OF CALIFORNIA HEALTH AND SAFETY
a civil penalty of not more than($500).) CODE, SECTION 25505 25533 AND 25534 CONCERNING
El I, as owner of the property, or my employees with wages as their sole HAZARDOUS MATERIAL REPORTING,
compensation,will do( )all of or( ) porting of the work, and the structure is PROPERTY OWNER OR AUTHORIZED AGENT
not intended or offered for sale.(Section 7044,Business and Professions Code;
The Contractor's State License Law does not apply to an owner of a property X
who, through employees' or personal effort, builds or improves the property,
provided that the improvements are not intended or offered for sale. If,however,
the building or improvement is sold within one year of completion, the Owner-
Builder will have the burden of proving that it was not built or improved for the
purpose of sale).
CITY Y OF MENIFEE PLCK No:
1�
29714 Haun Road Date: Date: '1
Menifee, CA 92586 v
Phone: (951)672-6777 Amount: Amount:
Fax:(951)679-3843 Ck#: Ck#: GISP
Building Combination Permit
To Be Completed By Applicant
Legal Description: Menifee Hills / El Dorado T31582-1 I
Planning Case: F: L: Rl: R:
Property address: Lot 132 29297 Nectarine St Assessors Parcel Number. 333 624 018
Project/Tenant Name: Unit#: Floor#:
T 31582-1 - Menifee Hills - Meridian
Name: Lennar Homes of California, Inc PhoneN$51-817-3680 I Fax No.
Property Address: Unit Number I Zip Code
Owner 980 Montecito Dr., Suite 302 Corona CA
Email Address:
eremiah.aca urri lennar.com
Name: Phone No. Fax No.
Jeremiah Aca turn 51-403-3715
Applicant Address: Unit Number Zip Code
same as above
Emagwdaress: jeremiah.acayturri@lennar.com
Name: Phone No. Fax No.
Contractor Address: City State Zip Code
Contractor's City Business License o. Contractor's City Stale of California License No. Classification: B
Number of Squares:
Square Footage 3.7 IkW/ 14 PCS/ 14 PCS
Description of Work: Solar Plan 2809 Elevation A-R cost of Work:s 9353.40
Applicant's Signature Date:
7/25/2014
To Be Completed By City Staff Only...
Indicate As R-Received or N/A-Not Applicable
5 Completes sets of fully dimensioned,drawn to sale plans which include: 'I set of documents which Include
❑ Title Sheet ❑ Elevations ❑ Electrical Plan ❑ Geo Tech/Soils Report(on cd only)
❑ Plot/Site Plan ❑ Roof Plan ❑ Mechanical Plan ❑ Title 24 Energy(on g%x 11)
❑ Foundation Plan ❑ Structural Calculations
❑ Cross Section ❑ Plumbing Plan ❑ Single Line diagram for elec.services over 400 AMP
❑ Floor Plan ❑ Structural Framing Plan&Details ❑ Shoring Plan 1 ❑ Sound Report-Residential
Class Code: Indicate New Construction Alteration' Addltion' Means/Methods
Work Type: Repair' Retrofit' Revislon to Existing Permit' Required? YES NO
Proposed Building Use(s): Existing Building Use(s):
#Buildings: #Units: it Stories: Will the Building Have a Basement?
Y of N
Bldg.Code Occupancy Group Indicate Indicate if YES or NO Indicate all Geo-tech.Haz.Zone
At Project Spdnkleretl that apply
Coastal Zone
Completion: Construction PP Y�
Type(s): C of O YES or NO Noise Zone
Required? Listed on Historic Resources Inventory
CITY PLANNING STAFF ONLY
APPROVALS: Costal cammiss Arch.Review Board Landmark Comm. I Planning Comm.Zoning Administrator
Fee Exempt: I City Project I Elec-Vehicle Charger Landmark Seismic Retrofit special Case:Bldg.
OfeoalA roval
Expedite Project(s)i Child Care City Project Green Building Landmark Affordable Housing
For Staff Use Only
Building/Safety I Permit 5pecialisl City Planning I Civil Engineering EPWM-Admin 11 Transportation Mgml. 1 Rent Control
THANK YOU FOR HELPING US CREATE A BETTER COMMUNITY
I
i
SYSTEM INFORMATION BUYER ACKNOWLEDGES THAT THE SOLAR MODULES TO BE INSTALLED
ITEM CITY MFR, MODEL ON THE ROOF OF THE HOME WILL BE SUBSTANTIALLY IN THE
SYSTEM S12E 3.71KW LOCATIONS INDICATED BY THE ILLUSTRATION.
MODULE 14 PCS. I BEND I PM250MOI(265W) BUYER:
INVERTER 14 PCS I ENPHASE I M215-60-2LL-S22-IG -- -
ROOF TYPE TILE W/COMPOSITE SHINGLE UNDER ARRAY DATE:SUB-ARRAY INFORMATION
INFORMATION
ARRAY#1 ARRAY#2 ARRAY#3
MOD OTY 14 N/A N/A BUYER'
TILT 23" N/A NIA
AZIMUTH 181- N/A N/A DATE:
CITY OF MENIFEE
BUILDING AND SAFETY DEPARTMENT
PI.7 N APPROVAL
23'-V,-ARRAY
REVIEWED BYIa4
` ATE
+Aps•roval of these plans shall mt be crI too( a
approval of,any violation of r proviso the fe ` st e o ci
regulations and ordinances. — is set of a • ved pla I be I ep sM
jobsite until completion.
i
SOLADECK WIRE
TRANSITION BOX
j (UNDER ARRAY)
II
UTILITY METER&
MAIN SERVICE PANEL
(VERIFIED BY BUILDER)
L————J
PV AC DISCONNECT
-y EXTERIOR-GARAGE
NOTE:DIMENSIONS ARE SHOWN IN PLANE OF ROOF
4
PLAN 2809 ELEVATION A-R
ORIENTATION 3 LOT#132
MERIDIAN AT 980LENNAR: ORIGINAL BY:
TOMB I DIERNALRUI DATE 14.7.14
980 MONTECITO DRIVE REVIEWED BY:TOM BIDDIES DATE 14.7J4
MENIFEE HILLS CORONA,CA 92789 REV.# BY DATE DESCRIPTION
namaste
DWG TITLE: PAGE#: SCALE: sorAe
SITE LOCATION:
INDIVIDUAL 4571&oaDO8Street
PLOT PLAN I/16'=1'-0' 29297 NECTARINE BT Boulder,303. 7030304
SYSTEM LAYOUT MENIFEE,CA 92584 303.447.0300 0.
' I
- ! i
4
3
L - C--
r
GUAVA STREET
N
PLAN 2809 ELEVATION A-R
ORIENTATION 3 LOT#:32
MERIDIAN AT LENNAR: ORIGINAL BY: FREDDY BERNALRUI DATE :4].14
980 MONTECITO DRIVE REVIEWED BY:TOM FIDDES DATE:14J.14
MENIFEE HILLS CORONA,CA 92789 REV,# BY DATE DESCRIPTION
t-mmasbd
SOLAR
DWG TITLE: PAGE#: SCALE SITE LOCATION:
INDIVIDUAL 48]i Ber.CC 8 Street
PLOT PLAN 2 I/64"=1'-0' 292W NECTARINE ST Boulder. 7030304
MENIFEE,CA 92584 30344]0300
SITE PLAN
MODULE SPECS AND CALCULATIONS INVERTER SPECS AND CALCULATIONS
ITEM NOTE/CALC UNIT DETAIL ITEM NOTE/CALC UNIT DETAIL
LOCATION MENIFEE,CA INV.MAKE INVERTER SPEC ENPHASE
TEMP,AMBIENT HIGH(TMAX) ASHRAE 2% °C 37 INV.MODEL INVERTER SPEC M215-60-2LL-522-IG
TEMP,AMBIENT LOW(THIN) ASHRAE EXTR.MIN 'C -2 INV. MAX POWER,(WAC MAX) INVERTER SPEC WATTS(AC) 225
TEMP,MODULE TEST(TTEST) MODULE SPEC °C 25 INV. INPUT V.(Voc MAX) INVERTER SPEC VOLTS(act 48
TEMP,DELTA LOW(TOELTA) THIN-TTEST °C -27 INV. OUTPUT V,(VAC NOM) INVERTER SPEC VOLTS(Ac) 240
MOD. MANUFACTURER MODULE SPEC BEND INV. OUTPUT FREQUENCY INVERTER SPEC HERTZ 60
MOD, PART NUMBER MODULE SPEC PM250MOI INV. OUTPUT CURRENT, IAC INVERTER SPEC AMPS(AC) 0.9
MOD. POWER STE(P) MODULE SPEC WATTS(DO 265 INV. PHASE QUANTITY INVERTER SPEC PHASE I
MOD, OPERATING VOLTAGE(VMP) MODULE SPEC VOLTS(00 31.30 COMPLIANCE INVERTER SPEC UL1741/IEEE1547
MOD. OPEN CCT. VOLTAGE(VGC) MODULE SPEC VOLTS(oc 38.20 INV. GROUNDING INVERTER SPEC ISOLATED
MOD.COEFF. VOLT/TEMP(COEF) MODULE SPEC V/°C -0.115 INV.OTY, MAX/BRANCH CCT. INV.OTYBC OTY 14
MOD.MAX VOLTAGE(VHAXMoo) (Voc i(To'COEF)) VOLTS(oc) 41.31 BRANCH CCT. OUTPUT, IMAXsc (IAC'I NV.QTYBc) AMPS(AC) 12.60
MOD.OPERATING CURRENT(IMP) MODULE SPEC AMPS(oC) 8,47 INV. OUANT IT Y.TOTAL INV.OTYT OTV 14
MOD.SHORT CCT. CURRENT(IGC) MODULE SPEC AMPS(DC) 8.98 TOTAL SYSTEM OUTPUT.IMAXTS (IAC•INV.QTYT) AMPS(Ad 1 12.60
MOD. MAXIMUM CURRENT(IMAX) (Ise' 1.25) AMPS(DU 11,25
MIN.AMPACITY REQD,PER NEC (MAX- 1,25) AMPS(DO I4.03
SERIES FUSE RATING,MAX MODULE SPEC AMPS(DO 15
ELECTRICAL EQUIPMENT SCHEDULE
KEY GUY MANUFACTURER MODEL NOTES TRADE
14 BEND PM250MOI(265W) PV MODULE SOLAR
2 14 ENPHASE M215-60-2LL-S22-IG PV INVERTER SOLAR
3 1 RSTC/SOLADECK 0786-3R5 PV ROOF JUNCTION BOX,NEMA 3R SOLAR
4 1 CUTLER-HAMMER DG221URB PV AC DISCONNECT,NEMA 3R,240V,30A SOLAR
5 1 ENPHASE ENVOY PV DATA MONITOR, 120V SOLAR
6 1 TBD TBD 120V DEDICATED RECEPTACLE FOR ENVOY PV DATA MONITOR SOLAR
7 1 TBD TBD CATS PORT FOR SOLAR PV INTERNET CONNECTION TO HOME NETWORK BOX SOLAR
8 NOTE CUTLER-HAMMER TBD PV BRANCH CIRCUIT BREAKERS;I X 15AHP(ENVOY) SOLAR
9 NOTE CUTLER-HAMMER TBD PV BREAKER,I x 20A-2P,LOCATE AT OPPOSITE END OF BUS FROM MAIN BREAKER SOLAR
10 TBD TBD SERVICE PANEL,MIN. 125A BUS FLUID. ELEC.
II TBD TBD UTILITY METER,ME, 120/24OV,200A BLUR. ELEC.
12 1 1 1 TBD I TBD I GROUNDING ELECTRODE DEER PLOD.ELEC.
CONDUCTOR SIZING CALCULATIONS INTERCONNECTION CALCULATIONS
1)CONDITION OF USE(COU: (AMPACITY'TEMP.DEBATE•FILL DEBATE)us. REO'D HMAX) ITEM UNIT PANEL
2)TERMINALS(TERM} AMPACITY AT TERMINALS.Vs. REO-D,(IMAX• L25) PANEL HER. CUTLER-HAMMER
KEY SIZE DUAL INSULATION CALC. AMPACITY W/O TEMP. FILL RESULT REO'D OCD BUS RATING AMPS 200
TYPE DEBATES DIRA TE DERATE (A) (A) USED(A) MAIN DISCONNECT AMPS 200
A #12 CU THWN-2 COU 30 J6 1.0 22.80 12,60 ALLOWED PV PER NEC AMPS 40.
TERM 25 25 15J5 20 PV OCPD DEVICE USED AMPS 20
B #10 CU NM-B GO U 40 .91 1.0 36.40 12.60
TERM 35 35 15.75 20
L #10 CU NMI COU 40 .91 1.0 36.40 12.60
TERM 35 35 15.75 20
CONDUCTOR SCHEDULE
-KEY CONDUCTORS CU/AL TYPE LOCATION TRADE
A 1-#12 ENGAGE CABLE. 1-#6G,FREE AIR CU TC-ER ARRAY SOLAR
B 3-#10, 1-#10 EGC CU NM-B(ROMEX) INTERIOR SOLAR
C 3-#10, H#10 EGC Cu NM-B(ROMEX) INTERIOR SOLAR
D CAT5E.ETHERNET CABLE CU CAT5E INTERIOR SOLAR
C0
0 0
8 3
G
I I I
EXTERIOR-GARAGE ROOF
ELECTRICAL DIAGRAM 3JInW
LOT# 132
MERIDIAN AT LENNAR ORIGINAL BY: FREDDY BERNALRUI DATE:14.7.14
980 MONTECITO DRIVE REVIEWED BY:TOM FIDDES I DATE:14.7.14
MENIFEE HILLS CORONA,CA 92789 REV.# BY DATE DESCRIPTION
namasGe
Ol R
DWG TITLE PAGE#: I SCALE: SITE LOCATION:
INDIVIDUAL 4571 Broadway Street
PLOT PLAN 3 NITS CA
NECTARINE ST Boultler,CO 80304
ELECTRICAL MENIFEE CA 92584 30344]0300
STRUCTURAL NOTES:
SOLAR CONTRACTOR-
S ALL PV ROOF ATTACHMENTS WILL BE SPACED ALONG MODULE RACKING RAILS AT NOT GREATER THAN 48"D.C.
2)ALL PV ROOF ATTACHMENTS WILL BE STAGGERED BY ROW AMONGST THE ROOF FRAMING MEMBERS,TO MAXIMUM EXTENT POSSIBLE.
5)ROOF PENETRATIONS ASSOCIATED WITH SOLAR RACKING WILL BE SEALED WITH AN APPROVED SEALANT.
4)SOLADECK WIRE TRANSITION BOX WILL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS. IT WILL BE FLASHED AND SEALED.
5)PV ARRAY WILL BE A MINIMUM OF 3"ABOVE THE COMPOSITE SHINGLE ROOF SURFACE.
6)THE UNIRAC SOLARMOUNT RACKING SYSTEM AND SOLAR PV ARRAY WILL BE INSTALLED ACCORDING TO THE UNIRAC SOLARMOUNT CODE-COMPLIANT INSTALLATION
MANUAL,VERSION 227 3,PUB 140I13-ICC,JANUARY 2014.
7)UNIRAC TOP CLAMPS REQUIRE A ONE INCH(I")SPACE BETWEEN PV MODULES. SOLARMOUNT RAILS MUST EXTEND A MINIMUM OF TWO INCHES(2")BEYOND THE EDGE
OF THE PV ARRAY/SUB-ARRAY.
8)UNIRAC SOLARMOUNT REQUIRES THAT A THERMAL EXPANSION GAP BE INSTALLED FOR ANY RAIL LENGTH OF GREATER THAN 40.
ROOFING CONTRACTOR-
1)DISTANCE BETWEEN ARRAY EDGE AND TRANSITION FLASHING(COMPOSITION TO TILE)WILL BE A MINIMUM OF 3.
2)26 GAUGE INTERLOCKING FLASHING'SIDEWALL'TO BE INSTALLED ALONG THE LENGTH OF THE PV ARRAY AT ROOFING MATERIAL TRANSITION. IT SHALL BE
APROVED PRIOR TO PV SYSTEM INSTALLATION.
3)PEEL-N-STICK BASE TO BE INSTALLED ONE FOOT H)OR MORE BEYOND THE EDGE OF THE COMPOSITION SHINGLE,DOWN TO THE ROOF EAVE. PEEL-N-STICK BASE TO
BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS.
4)AREAS UNDER EACH PV ARRAY SHALL BE ROOFED WITH COMPOSITION SHINGLE. COMPOSITION SHINGLE SHALL RUN FROM ABOVE THE PV ARRAY TO THE ROOF EAVE.
5)TILE INSTALLED BELOW THE ARRAY TO BE INSTALLED ABOVE THE COMPOSITION ROOF PER ROOFER SPECIFICATIONS.
6)BIRDSTOP WILL BE INSTALLED AT THE UPPERMOST TRANSITION FROM TILE TO COMPOSITION SHINGLE. BIRDSTOP TO BE SPECIFIED BY ROOFER PRIOR TO
INSTALLATION.
ELECTRICAL NOTES:
GENERAL-
1)ALL PV EQUIPMENT WILL BE TESTED AND LISTED FOR ITS USE BY A NATIONALLY RECOGNIZED TESTING LABORATORY(NRTL).
2)THE GROUNDING OF THE PHOTOVOLTAIC SYSTEM SHALL COMPLY WITH THE APPLICABLE VERSION OF THE NEC/CEC.
3)ALL GROUNDING ELECTRODE CONDUCTORS WILL BE INSTALLED IN A CONTINUOUS LENGTH EXCEPT WHERE SPLICED BY AN IRREVERSIBLE CONNECTOR OR EXOTHERMIC
WELD.
4)NON-CURRENT CARRYING METAL PARTS SHALL BE CHECKED FOR PROPER GROUNDING,NOTING THAT TERMINAL LUGS BOLTED ON AN ENCLOSURE'S FINISHED SURFACE
MAY BE ELECTRICALLY INSULATED BECAUSE OF PAINT/FINISH. PAINT/FINISH AT POINT OF CONTACT SHALL BE PROPERLY REMOVED.
5)ROOF PENETRATIONS WILL BE COMPLETED AND SEALED PER APPLICABLE CODE.
6)ALL CONDUCTORS WILL HAVE A 90'C RATING TO ENSURE CODE COMPLIANCE.
SOLAR CONTRACTOR-
7)MODULE CERTIFICATIONS WILL INCLUDE UL1703, IEC61646, IEC61730.
8)CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS.
9)RACEWAY POINT OF PENETRATION FROM EXTERIOR TO INTERIOR WILL BE SEALED TO PREVENT INGRESS OF WATER AND INSECTS.
10)DC WIRING IS LIMITED TO PV ARRAY FOOTPRINT W/ENPHASE MICRO-INVERTER SYSTEM.
III MODULE AND ENPHASE WIRING SHALL BE LOCATED AND SECURED UNDER THE ARRAY USING SUITABLE WIRING CLIPS. WIRING SHALL NOT MAKE CONTACT WITH THE
ROOF SURFACE AND SHALL BE MANAGED IN A WORKMAN-LIKE MANNER.
12)EQUIPMENT GROUNDING CONDUCTORS WILL BE SIZED IN ACCORDANCE WITH NEC TABLE 250.122.
13)CONDUCTOR TERMINATIONS WILL BE TORQUED PER DEVICE LISTING,OR MANUFACTURER'S RECOMMENDATIONS.
14)A PV AGGREGATION PANEL(SUB PANEL)WILL NOT BE INCLUDED FOR SYSTEMS WITH ONE BRANCH CIRCUIT.
15)A DEDICATED 120V BRANCH CIRCUIT IS REQUIRED IN MASTER CLOSET(OR EQUIVALENT)FOR ENPHASE ENVOY MONITOR.
SIGNAGE-
16)PV SYSTEMS SHALL BE CLEARLY MARKED IN ACCORDANCE WITH NEC ARTICLE 690 AND OTHER APPLICABLE STATE AND LOCAL CODES.
17)ALL SAFETY MARKING/PLACARDS SHALL BE PERMANENTLY ATTACHED BY ADHESIVE OR OTHER MECHANICAL MEANS.
18)MARKING /PLACARDS WILL BE METAL OR PLASTIC WITH ENGRAVED OR MACHINE PRINTED LETTERING. BACKGROUND WILL BE RED WITH WHITE CAPITAL LETTERING OF
MINIMUM HEIGHT y7
19)ALL WIRING/RACEWAYS/JUNCTION BOXES WILL BE MARKED'PHOTOVOLTAIC POWER SOURCE.'OR EQUIVALENT;WIRING/RACEWAYS SHALL BE MARKED EVERY 10'.
BUILDER ELECTRICAL AND SOLAR CONTRACTORS-
20)INSTALLATION SHALL BE COMPLETED IN A NEAT AND WORKMAN-LIKE MANNER.
20 SPACE REQUIREMENTS FOR ALL ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110.26-
MERIDIAN AT LENNAR: OR]G INAL BY: FREDDY BERNALRUI DATE:14.7.14
980 MONTECITO DRIVE REVIEWED BY:TOM FIDDES DATE:14.7.14
MENIFEE HILLS CORONA,CA 92789 REV.# BY DATE DESCRIPTION
Vncimastd
SOLAR
DWG TITLE: PAGE#: I SCALE: SITE LOCATION:
INDIVIDUAL 4871 Bmatlway SVeet
PLOT PLAN 4 NTS 29297 NECTARINE ST Bo C080304
NOTES MENIFEE,CA 92584 303.303.44]0300
CAUTION:
POWER TO THIS BUILDING IS SUPPLIED BY
THE UTILITY AND A SOLAR PV SYSTEM.
DISCONNECTS ARE LOCATED AS SHOWN.
SOLADECK WIRE
TRANSITION BOX
(UNDER ARRAY)
UTILITY METER 8
MAIN SERVICE PANEL
(VERIFIED BY BUILDER)
PV AC DISCONNECT
EXTERIOR-GARAGE
SERVICE BY QUALIFIED PERSONNEL ONLY
CONTACT: SUNSTREET ENERGY GROUP
1-877-SLR-POWR
NOTE: SEE MASTER SET FOR ADDITIONAL PLACARD INFORMATION
MERIDIAN AT ENNAR ORIGINAL BY: FREDDY BERNALRUI DATE:14.].14
980 MONTECITO DRIVE REVIEWED BY:TOM FIDDES DATE:14.7.14
MENIFEE HILLS CORONA,CA 92780 REV# BY DATE DESCRIPTION
Vnamasrd
aux
DWG TITLE: PAGE#: SCALE: SITE LOCATION:
INDIVIDUAL 4577lder GO 8Street
PLOT PLAN 5 NTS 89297 NECTARINE ST Boulder 17 30304
PLACARDS MENIFEE,CA 92584 303.4470300