Loading...
PMT14-02120 City of Menifee Permit No.: PMT14-02120 MENIFEE, EE, C 92 Type: Residential Electrical MENIFEE, CA 92586 MENIFEE Date Issued: 08/18/2014 1 I, PERMIT i Site Address: 29285 NECTARINE ST, MENIFEE, CA Parcel Number: 333-624-017 92584 Construction Cost: $8,017.20 Existing Use: Proposed Use: Description of SOLAR- 12 PANELS 3.18 KW LOT 131 Work: MASTER PLAN PMT14-00706 TR 31582-1 Owner Contractor '. LENNAR HOMES LENNAR HOMES OF CALIFORNIA INC 980 MONTECITO DR#302 25 ENTERPRISE CORONA, CA 92879 ALISO VIEJO, CA 92656 Applicant Phone: 9493498000 JEREMIAH ACAYTURRI License Number: 728102 25 ENTERPRISE ALISO VIEJO, CA 92656 Fee Description Qty Amount 0- Building Permit Issuance 1 27.00 GREENaFEE;."- sy� t° -i 0„. SMIP RESIDENTIAL 1 2.00 $282.00 The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and specifications or from preventing building operations being carried on thereunder when in violation of the Building Code or of any other ordinance of City of Menifee.Except as otherwise stated,a permit for construction under which no work is commenced within six months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be forfeited. AA_Bldg_Permil_Template.rpt Page 1 of 1 City Of Menifee LICENSED DECLARATION I hereby affirm under penalty or perjury that I am licensed under provisions of ❑ I, as owner of the property an exclusively contracting with licensed Chapter 9(commencing with section 7000)of Division 3 of the Business and contractors to construct the project(Section 7044, Business and Professions Professions Code and my license is in full force and effect. Code:The Contractor's License Law does not apply to an owner of a property License Class License No. who builds or improves thereon, and who contracts for the projects with a Expires Signature licensed contractor(s)pursuant to the Contractors State License Law). WORKERS'COMPENSATION DECLARATION ❑ I am exempt from licensure under the Contractors'State License Law for the ❑ I hereby affirm under penalty of perjury one of the following declarations: following reason: I have and will maintain a certificate of consent of self-insure for workers' By my signature below I acknowledge that, except for my personal residence in compensation,issued by the Director of Industrial Relations as provided for by which I must have resided for at least one year prior to completion of Section 3700 of the Labor Code, for the performance of work for which this 'improvements covered by this permit, I cannot legally sell a structure that I have permit is issued. built as an owner-building If it has not been constructed in its entirety by licensed Policy# contractors. I understand that a copy of the applicable law, Section 7044 of the ❑ I have and will maintain workers' compensation insurance, as required by Business and Professions Code,is available upon request when this application Is section 3700 of the Labor Code, for the performance of the work for which this submitted or at the following Web site:http�//www.leciinfo.ca.gov/calaw,html, permit is issued.My workers'compensation insurance carrier and policy number are: Carrier Properly Owner or Authorized Agent Date Expires Policy# ❑ By my Signature below, I certify to each of the following: I am the property Name of Agent Phone# owner or authorized to act on the property owner's behalf. I have read this (This section need not be completed if the permit is for application and the information I have provided is correct. I agree to comply one-hundred dollars($100)or less) with all applicable city and county ordinances and state laws relating to building construction.I authorize representatives of this city or county to enter the above- 0 1 certify that in the performance of the work for which this permit is issued,I identified property for the inspection purposes. shall not ample v any persons in any manner so as to become subject to the workers' compensation laws of California, and agree that if I should become subject to the workers'compensation provisions of Section 3700 of the Labor Property Owner or Authorized Agent Date Code,I shall forthwith comply with those provisions. City Business License# Date; Applicant; WARNING: FAILURE TO SECURE WORKERS' HAZARDOUS MATERIAL DECLARATION COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS WILL THE APPLICANT OR FUTURE BUILDING ($100,000), IN ADDITION TO THE COST OF COMPENSATION, ❑YES OCCUPANT HANDLE A HAZARDOUS MATERIAL OR A DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE MIXTURE CONTAINING A HAZARDOUS MATERIAL LABOR CODE, INTEREST,AND ATTORNEYS FEES ❑NO EQUAL TO OR GREATER THAN THE AMOUNTS CONSTRUCTION LENDING AGENCY SPECIFIED ON THE HAZARDOUS MATERIALS I hereby affirm that under the penalty of perjury there is a construction lending INFORMATION GUIDE? agency for the performance of the work which this permit is issued (Section WILL THE INTENDED USE OF THE BUILDING BY THE 3097 Civil Code) APPLICANT OR FUTURE BUILDING OCCUPANT REQUIRE Lender's Name DYES A PERMIT FOR THE CONSTRUCTION OR MODIFICATION FROM THE SOUTH COAST AIR QUALITY MANAGEMENT Lender's Address ❑NO DISTRICT(SCAQMD)SEE PERMITTING CHECKLIST FOR OWNER BUILDER DECLARATIONS GUIDE LINES I hereby affirm under penalty of perjury that I am exempt from the Contractor's PRINT NAME: License Law for the reason(s)indicated below by the checkmark(s)I have placed ❑YES WILL THE PROPOSED BUILDING OR MODIFIED FACILITY next to the applicable items) (Section 7031.5. Business and Professions Code: BE WITHIN 1000 FEET OF THE OUTER BOUNDARY OF A Any city or county that requires a permit to construct, alter, improve, demolish, ❑NO SCHOOL? or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with I HAVE READ THE HAZARDOUS MATERIAL Section 7000)of Division 3 of the Business and Professions Code)or that he or ❑YES INFORMATION GUIDE AND THE SCAQMD PERMITTING she is exempt from licensure and the basis for the alleged exemption. Any CHECKLIST. I UNDERSTAND MY REQUIREMENTS violation of Section 7031.5 by any Applicant for a permit subjects the applicant to ❑NO UNDER THE STATE OF CALIFORNIA HEALTH AND SAFETY a civil penalty of not more than ($500).) CODE, SECTION 25505, 25533 AND 25534 CONCERNING ❑ 1, as owner of the property, or my employees with wages as their sole HAZARDOUS MATERIAL REPORTING, compensation,will do ( )all of or ( ) porting of the work, and the structure is PROPERTY OWNER ORAUTHORIZED AGENT not intended or offered for sale.(Section 7044, Business and Professions Code; The Contractor's State License Law does not apply to an owner of a property X who, through employees' or personal effort, builds or improves the property, provided that the improvements are not intended or offered for sale.If,however, the building or improvement is sold within one year of completion,the Owner- Builder will have the burden of proving that it was not built or improved for the purpose of sale). CITY I� }��1G��T It Imo. it CI II 1 O 1`>/1JUl91lFEE PLCKNo: ly'V 1 O 29714 Haun Road Date: Date: Menifee, CA 92586 Phone: (951)672-6777 Amount Amount Fax:(951)679-3843 Ck#: Ck#: Building Combination Permit ,- nose ext (aY1 To Be Completed By Applicant Legal Description: Menifee Hills / El Dorado T31582-1 I Planning Case: F: L: Rt: R: Property Address: Lot 131 29285 Nectarine St Assessor's Parcel Number. 333 624 017 ProjectrIenant Name: Unit#: Floor#: T 31582-1 - Menifee Hills - Meridian Name: Lennar Homes of California, Inc Phone Fax Fax No. Property Address: Unit Number Zi Code Owner 980 Montecito Dr. Suite 302 Corona CA p909 Email Address: eremiah.aca urri lennar.com Name: Phone No. Fax No. Jeremiah Acayturri 951-403-3715 Applicant Address: same as above Unit Number Zip Code Email Address: jeremiah.acayturri@lennar.com Name: Phone No. Fax No. Contractor Address: City State Zip Code Contractor's City Business License o. Contractor's City State of California License No- Classification: B Number of Squares: Square Footage 3.18 kW/ 12 PCS / 12 PCS Description of Work: Solar PI n 2033 Elevation C Cost of Work:$8017.20 Applicant's Signature Date: 7/25/2014 To Be-C AMpleted By City Staff Only Indica As R-Received or N/A-Not Applicable 5 Completes sets of fully dimensioned,drawn to sale plans which include: 1 set of documents which include ❑ Title Sheet ❑ Elevations ❑ Electrical Plan ❑ Gen Tech/Soils Report(on cd only) ❑ Plot/Site Plan ❑ Roof Plan ❑ Mechanical Plan ❑ Title 24 Energy(on 8 Y x 11) ❑ Structural Calculations ❑ Foundation Plan ❑ Cross Section ❑ Plumbing Plan ❑ Single Line diagram for else.services over 400 AMP ❑ Floor Plan ❑ Structural Framing Plan&Details ❑ Shoring Plan ❑ Sound Report-Residential Class Code: Indicate New Construction Alteration' Addition' Means/Methods Work Type: Repair" - Retrofit` Revision to Existing Permir Required? YES NO Proposed Building Use(s): Existing Building Use(s): #Buildings: #Units: #Stories: Will the Building Have a Basement? Y of N Bldg.Code Occupancy Group Indicate Indicate If YES or NO Indicate all Go-tech.Haz.Zone. At Project Construction Sprinkleretl that apply: Coeastal Zone Completion: Type(s): C Of O Noise Zone Re uired7 YES or NO 9 Listed on Historic Resources Inventory CITY PLANNING STAFF ONLY APPROVALS: Costal Committee Arch.Review Board Landmark Comm. Planning Comm.Zoning Administrator Fee Exempt: City Project Else.Vehicle Charger Landmark Seismic Retrofit Special case:Bldg. Official Approval Expedite Project(s): Child Care City Project Green Building Landmark Affordable Housing For Staff Use Only Bullding/Safety, I Permit Specialist City Planning Civil Engineering EPWM-Admin I Transportation Mgmt. I Rent Control THANK YOU FOR HELPING US CREATE A BETTER COMMUNITY SYSTEM INFORMATION BUYER ACKNOWLEDGES THAT THE SOLAR MODULES TO BE INSTALLED ITEM OTY MFR, MODEL ON THE ROOF OF THE HOME WILL BE SUBSTANTIALLY IN THE SYSTEM SIZE 3.1801 LOCATIONS INDICATED BY THE ILLUSTRATION. MODULE 12 PCS. I BEND I PM250MOI(265W) BUYER. INVERTER 12 PCS. JENIPHASE I M215-60-2LL-S22-IG ROOF TYPE TILE W/COMPOSITE SHINGLE UNDER ARRAY DATE:—__ _ — - - ________-- SUB-ARRAY INFORMATION ARRAY#I 1 ARRAY#2 ARRAY#3 MOD OTY 12 NAN N/A BUYER: TILT 23° N/A I N/A AZIMUTH I81° 1 N/A DATE:N/A ' CITY OF MENIFEE BUILDING AND SAFETY DEPARTMENT IAN APPROVAL 19'-9fi''-ARRAY "-F SHING 16'-V' EVIEWED C, Jul III AJp/C�d af'hese M1:B:i'.Shad not be construe e a permit for, p{OUva;of,any violation of any provisions of t deral,state or ty _ regulations and ordinances. This set of approv ans must be ke — fobslte until completion. SOLADECK WIRE TRANSITION BOX (UNDER ARRAY) I UTILITY METER e MAIN.SERVICE PANEL (VERIFIED BY BUILDER) PV AC DISCONNECT EXTERIOR-GARAGE 0 N 0 NOTE:DIMENSIONS ARE SHOWN IN PLANE OF ROOF PLAN 2033 ELEVATION C ORIENTATION 3 LOT#131 MERIDIAN AT LENNAR- ORIGINAL BY: FREDDY BERNALRUI DATE 14.7.14 980 MONTECITO DRIVE REVIEWED BY:TOM FIDDES DATE 14.7.14 MENIFEE HILLS CORONA,CA 92789 REV.# BY DATE DESCRIPTION namast:e soue DWG TITLE: PAGE#: SCALE: SITE LOCATION: INDIVIDUAL 29206 NECTARINE ST 4671 Bo-,CO8dway Street PLOT PLAN 1 1/I6"=1'-0" MENIFEE,CA RINE Bo3084470300� SYSTEM LAYOUT T -� — -- -- I_ ri e� — 3 O W _ GUAVA STREET N PLAN 2033 ELEVATION C ORIENTATION 3 LOT#131 MERIDIAN AT LENNAR: ORIGINAL BY FREDDY BERNALROI DATE:147,14 980 MONTECITO DRIVE REVIEWED BY:TOM FIDDES I DATE:14 7.14 MENIFEE HILLS CORONA,CA 92789 REV.# BY DATE DESCRIPTION namasbe o .: DWG TITLE: PAGE It: SCALE: SITE LOCATION: INDIVIDUAL 4571 Broadway Street PLOT PLAN 2 I/64"=I'-0" 29285 NECTARINE ST B93034C00304 SITE PLAN MENIFEE,CA 92584 303.44]0300 MODULE SPECS AND CALCULATIONS INVERTER SPECS AND CALCULATIONS ITEM NOTE/CALC UNIT DETAIL ITEM NOTE/CALC UNIT DETAIL LOCATION MENIFEE,CA INV. MAKE INVERTER SPEC ENPHASE TEMP,AMBIENT HIGH(TMAR) ASHRAE 2% °C 37 INV. MODEL INVERTER SPEC M215-60-2LL-S22-IG TEMP,AMBIENT LOW(THIN) ASHRAE EXTR.MIN °C -2 INV. MAX POWER.(WAC MAX) INVERTER SPEC WATTS(AC) 225 TEMP,MODULE TEST(TTEST) MODULE SPEC •C 25 INV. INPUT V,(VOC MAX) INVERTER SPEC VOLTS(00 48 TEMP,DELTA LOW(TOECTA) THIN-TTEST •C -27 INV. OUTPUT V,(VAc NON) INVERTER SPEC VOLTS(Ac) 240 MOD. MANUFACTURER MODULE SPEC DENO INV. OUTPUT FREQUENCY INVERTER SPEC HERTZ 60 MOD. PART NUMBER MODULE SPEC PM250M01 INV. OUTPUT CURRENT, IAC INVERTER SPEC AMPS(AC) 0.9 MOD,POWER STC(P) MODULE SPEC WATTS(D0 265 INV. PHASE QUANTITY INVERTER SPEC PHASE I MOD. OPERATING VOLTAGE(VMP) MODULE SPEC VOLTS(0U 3L30 COMPLIANCE INVERTER SPEC UL174I/1EEEI547 MOD. OPEN OCT. VOLTAGE Nor) MODULE SPEC VOLTS(0c) 38.20 INV. GROUNDING INVERTER SPEC ISOLATED MOD. COEFF.VOLT/TEMP(COEF) MODULE SPEC V/-C -0.115 INV. OTY,MAX/BRANCH OCT. INV.QTYBC STY 12 MOD. MAX VOLTAGE(VMAXMOD) (Voc+(T0•COEF)) VOLTS(DO 41,31 BRANCH CCT. OUTPUT. IMAX C (IAc'INV.OTYBc) AMPS(Ac) 10.80 MOD.OPERATING CURRENT(IMP) MODULE SPEC AMPS(DC) 8.47 INV. QUANTITY, TOTAL INV.OTVT QTV 12 MOD.SHORT COL. CURRENT(Isc) MODULE SPEC AMPS(DO 8.98 TOTAL SYSTEM OUTPUT, IMAXTS (IAC'INV.QTYT) AMPS(AC) 10,80 MOD. MAXIMUM CURRENT([MAX) (Isc' 1.25) AMPS(DC) 11.23 MIN,AMPACITY RED'D,PER NEC (IMAX' 1.25) AMPS(DC) 14.03 SERIES FUSE RATING,MAX MODULE SPEC AMPS(Bc) 15 ELECTRICAL EQUIPMENT SCHEDULE KEY OTY MANUFACTURER MODEL NOTES TRADE 1 12 SENO PM250MOI(265W) PV MODULE SOLAR 2 12 ENPHASE M215-60-21LL-S22-I6 PVINVERTER SOLAR 3 1 RSTC/SOLADECK 0786-3R5 PV ROOF JUNCTION BOX,NEMA 3R SOLAR 4 1 CUTLER-HAMMER DG221URB PV AC DISCONNECT,NEMA DR,240V.30A SOLAR 5 1 ENPHASE ENVOY PV DATA MONITOR, 120V SOLAR 6 1 TBD TEO 120V DEDICATED RECEPTACLE FOR ENVOY PV DATA MONITOR SOLAR 7 1 TBD TBD CATS PORT FOR SOLAR PV INTERNET CONNECTION TO HOME NETWORK BOX SOLAR 8 NOTE CUTLER-HAMMER TBD PV BRANCH CIRCUIT BREAKERS;I X 15AHP(ENVOY) SOLAR 9 NOTE CUTLER-HAMMER TBD PV BREAKER. I x 2OA-2P,LOCATE AT OPPOSITE END OF BUS FROM MAIN BREAKER SOLAR 10 1 TBD TBD SERVICE PANEL, MIN. 125A BUS BLDR. ELEC. 11 TBD TBD UTILITY METER. PH, 120/240V,200A BLDR. ELEC. 12 TBD TOO GROUNDING ELECTRODE UFER BLDR ELEC, CONDUCTOR SIZING CALCULATIONS INTERCONNECTION CALCULATIONS 1)CONDITION OF USE(CCU): (AMPACITY'TEMP.BERATE•FILL BERATE)vs. REO'D(IMAX) ITEM UNIT PANEL 2)TERMINALS(TERM): AMPACITY AT TERMINALS. vs.REO'D,(IMAX" 1.25) PANEL HER. CUTLER-HAMMER KEY SIZE CU/AL INSULATION CALC. AMPACITY W/O TEMP. FILL RESULT REO'D OCD BUS RATING AMPS 200 TYPE DEBATES BERATE DEBATE (A) (A) USED(A) MAIN DISCONNECT AMPS 200 A #12 CU THWN-2 COU 30 .76 0 =3&4010� ALLOWED PV PER NEC AMPS 40 TERM 25 20 PV COED DEVICE USED AMPS 20 B #10 CU NM-B COU 40 .91 1.0 TERM 35 20 L #10 CU NM-B COU 40 .91 L0 TERM 35 20 CONDUCTOR SCHEDULE KEY CONDUCTORS CU/AL TYPE LOCATION TRADE A -#12 ENGAGE CABLE, -#6G,FREE AIR CI1 TC-ER ARRAY SOLAR B I 3-#10,1-#10 EGC N I NM-B(ROMEX) INTERIOR SOLAR C 3-#10,1-#10 EGG CO NM-B(ROMEX) INTERIOR SOLAR D CATSE,ETHERNET CABLE CU CAT5E INTERIOR SOLAR 6 5 D O m o v0 m SEE 0 NOTE 15 © OISP/IP C O9 PNJ B 3 j D I 1 EXTERIOR-GARAGE ROOF ELECTRICAL DIAGRAM 3.18KW LOT#131 MERIDIAN AT LENNAR: ORIGINAL BY: FREDDY BERNALRUI DATE 14.7.14 980 MONTECITO DRIVE REVIEWED BY:TOM FIDDES I DATE:14J.14 MENIFEE HILLS CORONA,CA 92789 REV.# BY DATE DESCRIPTION namasGe sosnv DWG TITLE: PAGE#: SCALE: SITE LOCATION: y Sireet INDIVIDUAL 4571lder,G 83M PLOT PLAN 3 NTS 29285 NECTARINE ST Boulder,C0 80304 ELECTRICAL MENIFEE,CA 92584 303.4410300 STRUCTURAL NOTES: SOLAR CONTRACTOR- S ALL PV ROOF ATTACHMENTS WILL BE SPACED ALONG MODULE RACKING RAILS AT NOT GREATER THAN 48"O.0 2)ALL PV ROOF ATTACHMENTS WILL BE STAGGERED BY ROW AMONGST THE ROOF FRAMING MEMBERS,TO MAXIMUM EXTENT POSSIBLE. 3)ROOF PENETRATIONS ASSOCIATED WITH SOLAR RACKING WILL BE SEALED WITH AN APPROVED SEALANT. 4)SOLADECK WIRE TRANSITION BOX WILL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS. IT WILL BE FLASHED AND SEALED. 5)PV ARRAY WILL BE A MINIMUM OF 3"ABOVE THE COMPOSITE SHINGLE ROOF SURFACE. 6)THE UNIRAC SOLARMOUNT RACKING SYSTEM AND SOLAR PV ARRAY WILL BE INSTALLED ACCORDING TO THE UNIRAC SOLARMOUNT CODE-COMPLIANT INSTALLATION 1 MANUAL,VERSION 227.3.PUB 140113-ICC.JANUARY 2014. 7)UNIRAC TOP CLAMPS REQUIRE A ONE INCH NP)SPACE BETWEEN PV MODULES.SOLARMOUNT RAILS MUST EXTEND A MINIMUM OF TWO INCHES(2")BEYOND THE EDGE OF THE PV ARRAY/SUB-ARRAY. 8)UNIRAC SOLARMOUNT REQUIRES THAT A THERMAL EXPANSION GAP BE INSTALLED FOR ANY RAIL LENGTH OF GREATER THAN 40'. ROOFING CONTRACTOR- U DISTANCE BETWEEN ARRAY EDGE AND TRANSITION FLASHING(COMPOSITION TO TILE)WILL BE A MINIMUM OF 3". 2)26 GAUGE INTERLOCKING FLASHING'SIDEWALL"TO BE INSTALLED ALONG THE LENGTH OF THE PV ARRAY AT ROOFING MATERIAL TRANSITION. IT SHALL BE APROVED PRIOR TO PV SYSTEM INSTALLATION. 3)PEEL-N-STICK BASE TO BE INSTALLED ONE FOOT U)OR MORE BEYOND THE EDGE OF THE COMPOSITION SHINGLE,DOWN TO THE ROOF EAVE.PEEL-N-STICK BASE TO BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS. 4)AREAS UNDER EACH PV ARRAY SHALL BE ROOFED WITH COMPOSITION SHINGLE. COMPOSITION SHINGLE SHALL RUN FROM ABOVE THE PV ARRAY TO THE ROOF RAVE. 5)TILE INSTALLED BELOW THE ARRAY TO BE INSTALLED ABOVE THE COMPOSITION ROOF PER ROOFER SPECIFICATIONS. 6)BIRDSTOP WILL BE INSTALLED AT THE UPPERMOST TRANSITION FROM TILE TO COMPOSITION SHINGLE. BIRDSTOP TO BE SPECIFIED BY ROOFER PRIOR TO INSTALLATION. ELECTRICAL NOTES: GENERAL- 1)ALL PV EQUIPMENT WILL BE TESTED AND LISTED FOR ITS USE BY A NATIONALLY RECOGNIZED TESTING LABORATORY(NRTL). 2)THE GROUNDING OF THE PHOTOVOLTAIC SYSTEM SHALL COMPLY WITH THE APPLICABLE VERSION OF THE NEC/CEC- 3)ALL GROUNDING ELECTRODE CONDUCTORS WILL BE INSTALLED IN A CONTINUOUS LENGTH EXCEPT WHERE SPLICED BY AN IRREVERSIBLE CONNECTOR OR EXOTHERMIC WELD. 4)NON-CURRENT CARRYING METAL PARTS SHALL BE CHECKED FOR PROPER GROUNDING,NOTING THAT TERMINAL LUGS BOLTED ON AN ENCLOSURE'S FINISHED SURFACE MAY BE ELECTRICALLY INSULATED BECAUSE OF PAINT/FINISH. PAINT/FINISH AT POINT OF CONTACT SHALL BE PROPERLY REMOVED. 5)ROOF PENETRATIONS WILL BE COMPLETED AND SEALED PER APPLICABLE CODE. 6)ALL CONDUCTORS WILL HAVE A 90-C RATING TO ENSURE CODE COMPLIANCE. SOLAR CONTRACTOR- 7)MODULE CERTIFICATIONS WILL INCLUDE UL1703, IEC61646, IEC61730. 8)CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS. 9)RACEWAY POINT OF PENETRATION FROM EXTERIOR TO INTERIOR WILL BE SEALED TO PREVENT INGRESS OF WATER AND INSECTS. 10)DC WIRING IS LIMITED TO PV ARRAY FOOTPRINT W/ENPHASE MICRO-INVERTER SYSTEM. IU MODULE AND ENPHASE WIRING SHALL BE LOCATED AND SECURED UNDER THE ARRAY USING SUITABLE WIRING CLIPS. WIRING SHALL NOT MAKE CONTACT WITH THE ROOF SURFACE AND SHALL BE MANAGED IN A WORKMAN-LIKE MANNER. 12)EQUIPMENT GROUNDING CONDUCTORS WILL BE SIZED IN ACCORDANCE WITH NEC TABLE 250.122. 13)CONDUCTOR TERMINATIONS WILL BE TORQUED PER DEVICE LISTING,OR MANUFACTURER'S RECOMMENDATIONS. 14)A PV AGGREGATION PANEL(SUB PANEL)WILL NOT BE INCLUDED FOR SYSTEMS WITH ONE BRANCH CIRCUIT. 15)A DEDICATED 120V BRANCH CIRCUIT IS REQUIRED IN MASTER CLOSET(OR EQUIVALENT)FOR ENPHASE ENVOY MONITOR. SIGNAGE- 16)PV SYSTEMS SHALL BE CLEARLY MARKED IN ACCORDANCE WITH NEC ARTICLE 690 AND OTHER APPLICABLE STATE AND LOCAL CODES, 17)ALL SAFETY MARKING/PLACARDS SHALL BE PERMANENTLY ATTACHED BY ADHESIVE OR OTHER MECHANICAL MEANS. 18)MARKING /PLACARDS WILL BE METAL OR PLASTIC WITH ENGRAVED OR MACHINE PRINTED LETTERING. BACKGROUND WILL BE RED WITH WHITE CAPITAL LETTERING OF MINIMUM HEIGHT y3". 19)ALL WIRING/RACEWAYS/JUNCTION BOXES WILL BE MARKED'PHOTOVOLTAIC POWER SOURCE,' OR EQUIVALENT:WIRING/RACEWAYS SHALL BE MARKED EVERY 10'. BUILDER ELECTRICAL AND SOLAR CONTRACTORS- 20)INSTALLATION SHALL BE COMPLETED IN A NEAT AND WORKMAN-LIKE MANNER. 21)SPACE REQUIREMENTS FOR ALL ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110.26. MERIDIAN AT LENNAR: ORIGINAL BY: FREDDY BFRNI DATE:14.714 980 MONTECITD DRIVE REVIEWED BY:TOM FIBRES DATE:14.7.14 MENIFEE HILLS CORONA,CA 92789 REV,# BY DATE DESCRIPTION namaste SOLA[ DWG TITLE: PAGE K: SCALE: SITE LOCATION: 4571 7M1 Broadway Street PLOT PLAN 4 NTS 29285 NECTARINE ST Dodder,4 00 80304 NOTES MENIFEE,CA 92584 303447.0300 CAUTION: POWER TO THIS BUILDING IS SUPPLIED BY THE UTILITY AND A SOLAR PV SYSTEM. DISCONNECTS ARE LOCATED AS SHOWN. SOLADECK WIRE TRANSITION BOX (UNDER ARRAY) UTILITY METER 8 MAIN SERVICE PANEL (VERIFIED BY BUILDER) PV AC DISCONNECT EXTERIOR-GARAGE SERVICE BY QUALIFIED PERSONNEL ONLY CONTACT: SUNSTREET ENERGY GROUP 1-877-SLR-POWR NOTE: SEE MASTER SET FOR ADDITIONAL PLACARD INFORMATION MERIDIAN AT ENNAR: ORIGINAL BY: FREDDY BERNALRUI DATE:147J4 980 MONTECITO DRIVE REVIEWED BY:TOM FIDDES I DATE:14.7.14 MENIFEE HILLS CORONA,CA 92789 REV.# 8Y DATE DESCRIPTION Vnamcist;6 aoiav DWG TITLE: PAGE#: SCALE: SITE LOCATION: INDIVIDUAL 4571 Broadway Street PLOT PLAN 5 NTS 29285 NECTARINE ST Boulder,GOCO80304 MENIFEE,CA 92584 303447.0300 PLACARDS