Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
PMT14-02119
City of Menifee Permit No.: PMT14-02119 29714 HAUN RD. 'WCCEL A MENIFEE, CA 92586 Type: Residential Electrical s"'""`x"ASA." MENIFEE Date Issued: 0 8/1 812 0 1 4 i PERMIT Site Address: 29273 NECTARINE ST, MENIFEE, CA Parcel Number: 333-624-016 92584 Construction Cost: $10,689.60 Existing Use: Proposed Use: Description of SOLAR- 16 PANELS 4.24 KW LOT 130 Work: MASTER PLAN PMT14-00706 TR 31582-1 Owner Contractor LENNAR HOMES LENNAR HOMES OF CALIFORNIA INC 980 MONTECITO DR#302 25 ENTERPRISE CORONA, CA 92879 ALISO VIEJO, CA 92656 Applicant Phone: 9493498000 JEREMIAH ACAYTURRI License Number: 728102 25 ENTERPRISE ALISO VIEJO, CA 92656 Fee Description Qtyr Amount Solo e1 e..,n1 1 o" mall Coinme aalIn Building Permit Issuance 1 27.00 SMIP RESIDENTIAL 1 2.00 $282,00 The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and specifications or from preventing builiding operations being carried on thereunder when in violation of the Building Code or of any other ordinance of City of Menifee. Except as otherwise slated, a permit for construction under which no work is commenced within six months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be forfeited. AA_Bldg_Permit Template.rpt Page 1 of 1 City Of Menifee LICENSED DECLARATION I hereby affirm under penalty or perjury that I am licensed under provisions of ❑ I, as owner of the property an exclusively contracting with licensed Chapter 9(commencing with section 7000)of Division 3 of the Business and contractors to construct the project(Section 7044, Business and Professions Professions Code and my license is in full force and effect. Code:The Contractor's License Law does not apply to an owner of a property License Class License No. who builds or improves thereon, and who contracts for the projects with a Expires Signature licensed contractor(s)pursuant to the Contractors State License Law). WORKERS'COMPENSATION DECLARATION ❑ I am exempt from licensure under the Contractors'State License Law for the ❑ I hereby affirm under penalty of perjury one of the following declarations: following reason: I have and will maintain a certificate of consent of self-insure for workers' By my signature below I acknowledge that, except for my personal residence in compensation,issued by the Director of Industrial Relations as provided for by which I must have resided for at least one year prior to completion of Section 3700 of the Labor Code, for the performance of work for which this improvements covered by this permit, I cannot legally sell a structure that I have permit is issued. built as an owner-building if it has not been constructed in its entirety by licensed Policy# contractors. I understand that a copy of the applicable law, Section 7044 of the ❑ 1 have and will maintain workers' compensation insurance, as required by Business and Professions Code,is available upon request when this application is section 3700 of the Labor Code, for the performance of the work for which this submitted or at the following Web site:http'//www leoinfo ca gov/calaw htm1. permit is issued, My workers'compensation insurance carrier and policy number are: Property Owner or Authorized Agent Date Carrier Expires Policy# ❑ By my Signature below, I certify to each of the following: I am the property Name of Agent Phone# owner or authorized to act on the property owner's behalf. I have read this (This section need not be completed if the permit is for application and the information I have provided Is correct. I agree to comply one-hundred dollars($100)or less) with all applicable city and county ordinances and state laws relating to building construction.I authorize representatives of this city or county to enter the above- El I certify that in the performance of the work for which this permit is issued,I identified property for the inspection purposes. shall not employ any persons in any manner so as to become subject to the workers' compensation laws of California, and agree that if I should become subject to the workers'compensation provisions of Section 3700 of the Labor Property Owner or Authorized Agent Date Code, I shall forthwith comply with those provisions. City Business License# Date; Applicant; WARNING: FAILURE TO SECURE WORKERS' HAZARDOUS MATERIAL DECLARATION COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS WILL THE APPLICANT OR FUTURE BUILDING ($100,000), IN ADDITION TO THE COST OF COMPENSATION, OYES OCCUPANT HANDLEA HAZARDOUS MATERIAL ORA DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE MIXTURE CONTAINING A HAZARDOUS MATERIAL LABOR CODE, INTEREST,AND ATTORNEYS FEES ❑NO EQUAL TO OR GREATER THAN THE AMOUNTS CONSTRUCTION LENDING AGENCY SPECIFIED ON THE HAZARDOUS MATERIALS I hereby affirm that under the penalty of perjury there is a construction lending INFORMATION GUIDE? agency for the performance of the work which this permit Is issued (Section WILL THE INTENDED USE OF THE BUILDING BY THE 3097 Civil Code) APPLICANT OR FUTURE BUILDING OCCUPANT REQUIRE Lender's Name OYES A PERMIT FOR THE CONSTRUCTION OR MODIFICATION FROM THE SOUTH COAST AIR QUALITY MANAGEMENT Lender's Address El NO DISTRICT(SCAQMD) SEE PERMITTING CHECKLIST FOR GUIDE LINES OWNER BUILDER DECLARATIONS I hereby affirm under penalty of perjury that I am exempt from the Contractor's PRINT NAME: License Law for the reasons)indicated below by the checkmark(s)I have placed OYES WILL THE PROPOSED BUILDING OR MODIFIED FACILITY next to the applicable items) (Section 7031.5. Business and Professions Code: BE WITHIN 1000 FEET OF THE OUTER BOUNDARY OF A Any city or county that requires a permit to construct, alter, improve, demolish, ❑NO SCHOOL? or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law(Chapter 9 (commencing with HAVE READ THE HAZARDOUS MATERIAL Section 7000)of Division 3 of the Business and Professions Code)or that he or OYES INFORMATION GUIDE AND THE SCAQMD PERMITTING she is exempt from licensors and the basis for the alleged exemption. Any CHECKLIST. I UNDERSTAND MY REQUIREMENTS violation of Section 7031.5 by any Applicant for a permit subjects the applicant to ❑NO UNDER THE STATE OF CALIFORNIA HEALTH AND SAFETY a civil penalty of not more than($500).) HAZARDOUS CODE, S 8TIION 2 505FfE 5533 AND 25534 CONCERNING ❑ 1, as owner of the property, or my employees with wages as their sole compensation, will do ( ) all of or( ) porting of the work, and the structure is PROPERTY OWNER OR AUTHORIZED AGENT not intended or offered for sale.(Section 7044,Business and Professions Code; The Contractor's Stale License Law does not apply to an owner of a property X who, through employees' or personal effort, builds or improves the property, provided that the improvements are not intended or offered for sale.If,however, the building or improvement is sold within one year of completion, the Owner- Builder will have the burden of proving that it was not built or improved for the purpose of sale). CITY OF MENI ,EE PLCK No, it -t— 119 29714 Haun Road Date: Date: Menifee, CA 92586 I �� Phone: (951)672-6777 Amount: AmouQt:��Q a Fax:(951)679-3843 Ck#: Ck#: C11 `5? Building Combination Permit Phase 3 - N1cYliAtgh To Be Completed By Applicant Legal Description: Menifee Hills/ El Dorado T31582-1 I Planning Case: F: L: Rt: R: Property address: Lot 130 29273 Nectarine St Assessor's Parcel Number. 333 624 016 ProjecMnant Name: Unit#: Floor* 31582-1 - Menifee Hills - Meridian Name: Lennar Homes of California, Inc Phone N�51-817-3680 Fax No. Property Address: Unit Number Zf Code 9 Owner 980 Montecito Dr. Suite 302 Corona CA p Email Address: eremiah.aca urri lennar.com Name: Phone No. Fax No, Jeremiah Acayturri 951-403-3715 Applicant Address: same as above Unit Number Zip Code Email Address: jeremiah.acayturd@lennar.com Name: Phone No. Fax No. Contractor Address: City State Zip Code Contractor's City Business License o- Contractor's City State of California License Na_ Classification: B Number of Squares: Square Footage 4.24 kW/ 16 PCS / 16 PCS Description of Work: SolarPqn 2999 Elevation B cost of Work:s 10689.60 Applicant's Signature Date: 7/25/2014 e Completed By City Staff Only ndicate As R-Received or NIA-Not Applicable 5 Completes sets of fully dimensioned,drawn to sale plans which include; 1 set of documents which include ❑ Title Sheet ❑ Elevations ❑ Electrical Plan ❑ Gen Tech/Soils Report(on ed only) ❑ Plot/Site Plan ❑ Roof Plan ❑ Mechanical Plan ❑ Title 24 Energy(on 8%x 11) ❑ Foundation Plan ❑ Structural Calculations ❑ Cross Section ❑ Plumbing Plan ❑ Single Line diagram for elec.services over 400 AMP ❑ Floor Plan ❑ SWcural Framing Plan 8 Details ❑ Shoring Plan ❑ Sound Report-Residential Class Code: Indicate UNewConstruction Alteration* Addition* Means/Methods Work Type: Repair* Retrofit` Revision to Existing PellW Required? YES NO Proposed Building Use(s): Existing Building Use(s): #Buildings: #Units: 11 Stories: Will the Building Have a Basement? Y of N Bldg-Code Occupancy Group Indicate indicate if Indicate all Geo-tech-Haz.Zone At Project Sprinklered YES or NO that a I Coastal Zone Completion: Construction PP y: Type(s): C of O YES or NO Noise Zone Required? Listed on Historic Resources Inventory CITY PLANNING STAFF ONLY APPROVALS: Costal Commiss lArch.ReviewBoard I Landmark Comm. Planning Comm.Zoning Administrator Fee Exempt City Project I JElec-Vehicle Charger Landmark Seismic Retrofitl speclal Case: mg. OfficieApprw.1 Expedite Project(s): Child Care City Project Green Building Landmark Affordable Housing For Staff Use Only Building/Safety I Permit Specialist City Planning I Civil Engineering EPWM-Admin Transpodakon Mgmt. I Rent Control THANK YOU FOR HELPING US CREATE A BETTER COMMUNITY i SYSTEM INFORMATION BUYER ACKNOWLEDGES THAT THE SOLAR MODULES TO BE INSTALLED ITEM OTY MI MODEL ON THE ROOF OF THE HOME WILL BE SUBSTANTIALLY IN THE SYSTEM SIZE 4.24KW I LOCATIONS INDICATED BY THE ILLUSTRATION. MODULE 16 PCS. I BEND I PM250MOI(265W) BUYER: INVERTER 16 PCS I ENPHASE I M2I5-60-2LL-S22-IG ROOF TYPE TILE W/COMPOSITE SHINGLE UNDER ARRAY DATE—_---___—_--- SUB-ARRAY INFORMATION ARRAY#I ARRAY#2 ARRAY#3 MOD CITY 16 N/A1 N/A BUYER:_ N/A H r IV] WHIZ I e N/A DATE— -- - UILDING AND SAFETY DEPARTMENT LAN APPROVAL REVIEWED SY ARRAY "-FLASHING 5'-4" DA 'Approval of these plans sha,i not be construed to he a pe o,or an approval of,any violation of any provisions of the federal, o cit regulations and ordinances. This set of approved plans mu k pt n t e obsite until completion. _ SOLADECK WIRE TRANSITION BOX (UNDER ARRAY) I UTILITY METER 8 MAIN SERVICE PANEL (VERIFIED BY BUILDER) i I PV AC DISCONNECT J EXTERIOR-GARAGE (. 99 i, NOTE:DIMENSIONS ARE SHOWN IN PLANE OF ROOF PLAN ELEVATION B ORIENTATION 3 LOT#130 MERIDIAN AT LENNAR: ORIGINAL BY: FREDDY BERNALRUI DATE:14-7.14 980 MONTECITO DRIVE REVIEWED BY TOM FIDDES DATE:14.7.14 MENIFEE HILLS CORONA,CA 92789 REV.# BY DATE I DESCRIPTION gragnanriast;di C TWO TITLE PAGE#: SCALE: SITE LOCATION: mue j INDIVIDUAL 4571ld..CBroaft 8Street PLOT PLAN I/16'=1'-0' 292]3 NECTARINE ST B9303447O 80304 A SYSTEM LAYOUT MENIFEE,CA 92584 30344].0300 (r!, � RAILL Edp QL E Ij 13 STREET cn O W <, N PLAN 2999 ELEVATION B ORIENTATION 3 LOT#130 MERIDIAN AT ENNAR: ORIGINAL BY: FREDDY BERNALRUI DATE:14.7.14 980 MONTECITO DRIVE REVIEWED BY:TOM FIDDES DATE:14.7.14 MENIFEE HILLS CORONA,CA 92789 REV.# BY DATE DESCRIPTION Vnamast( SOLAR DWG TITLE: PAGE#: SCALE: SITE LOCATION: treet INDIVIDUAL 4Bo Ber,CO 30,1 PLOT PLAN 2 I/64"=P-0" 29273 NECTARINE ST BO3034 7030304 SITE PLAN MENIFEE,CA 92584 303a410300 MODULE SPECS AND CALCULATIONS INVERTER SPECS AND CALCULATIONS ITEM NOTE 7 CALC UNIT DETAIL ITEM NOTE/CALC UNIT DETAIL LOCATION MENIFEE,CA INV. MAKE INVERTER SPEC ENPHASE TEMP,AMBIENT HIGH(TMAX) ASHRAE 2% °C 37 INV. MODEL INVERTER SPEC M215-60-2LL-S22-IG TEMP,AMBIENT LOW(THIN) ASHRAE EXTR:MIN -C -2 INV. MAX POWER,(WAC MAX) INVERTER SPEC WATTS(Ac) 225 TEMP,MODULE TEST(TTEST) MODULE SPEC "C 25 INV. INPUT V,(VDC MAX) INVERTER SPEC VOLTS(DC) 48 TEMP,DELTA LOW(TOELTA) TNIN-TTEST 'C -27 INV. OUTPUT V.(VAc NOM) INVERTER SPEC VOLTS(Ad 240 MOD. MANUFACTURER MODULE SPEC DENO INV. OUTPUT FREQUENCY INVERTER SPEC HERTZ 60 MOD.PART NUMBER MODULE SPEC PM250MOI INV. OUTPUT CURRENT,IAC INVERTER SPEC AMPS(Ad) 0.9 MOD. POWER STC(P) MODULE SPEC WATTS(Do) 265 INV.PHASE QUANTITY INVERTER SPEC PHASE I MOD. OPERATING VOLTAGE(VMP) MODULE SPEC VOLTS(DU 31.30 COMPLIANCE INVERTER SPEC UL1741/IEEE1547 MOD, OPEN CCT. VOLTAGE(Vac) MODULE SPEC VOLTS(DO 3&20 INV. GROUNDING INVERTER SPEC ISOLATED MOD, COEFF. VOLT/TEMP(COEF) MODULE SPEC V/°C -0.115 INV.OTY,MAX/BRANCH CCT. INV.DTYMc QTY 16 MOD.MAX VOLTAGE(VMAXMOD) (VDC+(TD'CaeF)) VOLTS(Dc) 41.31 BRANCH CCT.OUTPUT,Inaxnc (lac`INV.QTYDc7 I AMPS(Ad) 14.40 MOD.OPERATING CURRENT(IMP) MODULE SPEC AMPS(DC) 8.47 INV. QUANTITY,TO- IINV.QTYT I QTY 16 MOD.SHORT CCT.CURRENT OSC) MODULE SPEC AMPS Dot) 8.98 TOTAL SYSTEM OUTPUT, IMAXTS (1401NV.QTYT) I AMPS(Ac) 1 14.40 MOD.MAXIMUM CURRENT(MAX) OsC' 1.25) AMPS(Dc) 11.25 MIN.AMPACITY REQ'D,PER NEC HMAX- 1.25) AMPS(Do) 14.03 SERIES FUSE RATING,MAX MODULE SPEC AMPS(DC) 15 ELECTRICAL EQUIPMENT SCHEDULE IKEY OTY MANUFACTURER MODEL NOTES TRADE 1 16 BEND PM250MOI(265W) PV MODULE SOLAR 2 16 ENPHASE M2I5-60-2LL-S22-IG PV INVERTER SOLAR 3 1 RSTC/SOLADECK 0786-3R5 PV ROOF JUNCTION BOX,NEMA 3R SOLAR 4 1 CUTLER-HAMMER DG221URB PV AC DISCONNECT,NEMA 3R,240V.30A SOLAR 5 1 ENPHASE ENVOY PV DATA MONITOR, 120V SOLAR 6 1 TBD TBD 120V DEDICATED RECEPTACLE FOR ENVOY PV DATA MONITOR SOLAR 7 1 TBD TBD CATS PORT FOR SOLAR PV INTERNET CONNECTION TO HOME NETWORK BOX SOLAR 8 NOTE CUTLER-HAMMER TBD PV BRANCH CIRCUIT BREAKERS;I x 15A-IP(ENVOY) SOLAR 9 NOTE CUTLER-HAMMER TBD PV BREAKER, Ix 20A-2P,LOCATE AT OPPOSITE END OF BUS FROM MAIN BREAKER SOLAR 10 1 TBD TBD SERVICE PANEL, MIN. 125A BUS BLDR. ELEC. 11 1 TBD TBD 1 UTILITY METER, IPH,120/24OV,200A BLDR- ELEC. 12 TBD TBD GROUNDING ELECTRODE UFER BLDR- ELEC. CONDUCTOR SIZING CALCULATIONS INTERCONNECTION CALCULATIONS 1)CONDITION OF USE(COU): (AMPACITY'TEMP.DERATE'FILL DEBATE)VS. REOD(IMAX) ITEM UNIT PANEL 2)TERMINALS(TERM): AMPACITY AT TERMINALS.Vs. REQ'O.OMAX' 1.25) PANEL MFR. CUTLER-HAMMER KEY SIZE CU/AL INSULATION CALC. AMPACITY W/O TEMP. FILL RESULT REOD OCD BUS RATING AMPS 200 TYPE DERATES DERATE DERATE (A) (A) USED(A) MAIN DISCONNECT AMPS 200 A #12 CU THWN-2 COU 30 .76 1.0 22.80 14.40 ALLOWED PV PER NEC AMPS 40 TERM 25 25 18.00 20 PV OCPD DEVICE USED AMPS 20 B #10 Cu NM-B. CON 40 '91 1.0 36.40 14.40 TERM 35 35 18.00 20 C #10 Cu NM-B COU 40 .91 A 36.40 14.40 TERM 35 35 18,00 20 CONDUCTOR SCHEDULE KEY CONDUCTORS CUI TYPE LOCATION TRAOE A -#12 ENGAGE CABLE, -#6G,FREE AIR LU TC-ER ARRAY SOLAR B 3-#10,I-410 EGC CO NM-B(ROMEX) INTERIOR ISOLAR C 3-#10,1-#10 EGC CU NM-B(ROMEX) I INTERIOR ISOLAR D CAT5E,ETHERNET CABLE CU CAT5e I INTERIOR ISOLAR 11 © 5 D O5.1 o �O SEE 10 NOTE 15 ® 0 SNIP 9 c Z0Al2P O O D 3 6 12 ( I I EXTERIOR-GARAGE ROOF ELECTRICAL DIAGRAM 4.24xW LOT#130 MERIDIAN AT LEHMAN: ORIGINAL BY: FREDDY BERNALRUI DATE:14 7 14 9BO MONTECITO DRIVE REVIEWED BY:TOM RIDGES DATE:14.7.14 MENIFEE HILLS CORONA,CA 92789 REV.# BY DATE DESCRIPTION Vnamasbd Ot/R DWG TITLE: PAGE#: SCALE: SITE LOCATION: INDIVIDUAL 4571 CC 8Street 29273 NECTARINE ST BD303 d.4 7 30304 PLOT PLAN 3 NTS ELECTRICAL MENIFEE,CA 92584 0344]000 STRUCTURAL NOTES: SOLAR CONTRACTOR- U ALL PV ROOF ATTACHMENTS WILL BE SPACED ALONG MODULE RACKING RAILS AT NOT GREATER THAN 48'O.C. 2)ALL PV ROOF ATTACHMENTS WILL BE STAGGERED BY ROW AMONGST THE ROOF FRAMING MEMBERS,TO MAXIMUM EXTENT POSSIBLE. 3)ROOF PENETRATIONS ASSOCIATED WITH SOLAR RACKING WILL BE SEALED WITH AN APPROVED SEALANT. 4)SOLADECK WIRE TRANSITION BOX WILL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS. IT WILL BE FLASHED AND SEALED. 5)PV ARRAY WILL BE A MINIMUM OF 3-ABOVE THE COMPOSITE SHINGLE ROOF SURFACE. 6)THE UNIRAC SOLARMOUNT RACKING SYSTEM AND SOLAR PV ARRAY WILL BE INSTALLED ACCORDING TO THE UNIRAC SOLARMOUNT CODE-COMPLIANT INSTALLATION MANUAL,VERSION 227.3.PUB 140113-ICC,JANUARY 20I4. 7)UNIRAC TOP CLAMPS REQUIRE A ONE INCH Q)SPACE BETWEEN PV MODULES. SOLARMOUNT RAILS MUST EXTEND A MINIMUM OF TWO INCHES(2.)BEYOND THE EDGE OF THE PV ARRAY/SUB-ARRAY. 8)UNIRAC SOLARMOUNT REQUIRES THAT A THERMAL EXPANSION GAP BE INSTALLED FOR ANY RAIL LENGTH OF GREATER THAN 40'. ROOFING CONTRACTOR- H DISTANCE BETWEEN ARRAY EDGE AND TRANSITION FLASHING(COMPOSITION TO TILE)WILL BE A MINIMUM OF 3'. 2)26 GAUGE INTERLOCKING FLASHING'SIDEWALL"TO BE INSTALLED ALONG THE LENGTH OF THE PV ARRAY AT ROOFING MATERIAL TRANSITION. IT SHALL BE APROVED PRIOR TO PV SYSTEM INSTALLATION. 3)PEEL-N-STICK BASE TO BE INSTALLED ONE FOOT(L7 OR MORE BEYOND THE EDGE OF THE COMPOSITION SHINGLE,DOWN TO THE ROOF EAVE.PEEL-N-STICK BASE TO BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS. 4)AREAS UNDER EACH PV ARRAY SHALL BE ROOFED WITH COMPOSITION SHINGLE. COMPOSITION SHINGLE SHALL RUN FROM ABOVE THE PV ARRAY TO THE ROOF EAVE. 5)TILE INSTALLED BELOW THE ARRAY TO BE INSTALLED ABOVE THE COMPOSITION ROOF PER ROOFER SPECIFICATIONS. 6)BIRDSTOP WILL BE INSTALLED AT THE UPPERMOST TRANSITION FROM TILE TO COMPOSITION SHINGLE. BIRDSTOP TO BE SPECIFIED BY ROOFER PRIOR TO INSTALLATION. ELECTRICAL NOTES: GENERAL- 1)ALL PV EQUIPMENT WILL BE TESTED AND LISTED FOR ITS USE BY A NATIONALLY RECOGNIZED TESTING LABORATORY(NRTL). 2)THE GROUNDING OF THE PHOTOVOLTAIC SYSTEM SHALL COMPLY WITH THE APPLICABLE VERSION OF THE NEC/CEC. 3)ALL GROUNDING ELECTRODE CONDUCTORS WILL BE INSTALLED IN A CONTINUOUS LENGTH EXCEPT WHERE SPLICED BY AN IRREVERSIBLE CONNECTOR OR EXOTHERMIC WELD, 4)NON-CURRENT CARRYING METAL PARTS SHALL BE CHECKED FOR PROPER GROUNDING,NOTING THAT TERMINAL LUGS BOLTED ON AN ENCLOSURE'S FINISHED SURFACE MAY BE ELECTRICALLY INSULATED BECAUSE OF PAINT/FINISH. PAINT/FINISH AT POINT OF CONTACT SHALL BE PROPERLY REMOVED. 5)ROOF PENETRATIONS WILL BE COMPLETED AND SEALED PER APPLICABLE CODE. 6)ALL CONDUCTORS WILL HAVE A 90°C RATING TO ENSURE CODE COMPLIANCE. SOLAR CONTRACTOR- 7)MODULE CERTIFICATIONS WILL INCLUDE ULI703,IEC61646, IEC61730. 8)CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS. 9)RACEWAY POINT OF PENETRATION FROM EXTERIOR TO INTERIOR WILL BE SEALED TO PREVENT INGRESS OF WATER AND INSECTS. 10)DC WIRING IS LIMITED TO PV ARRAY FOOTPRINT W/ENPHASE MICRO-INVERTER SYSTEM. 11)MODULE AND ENPHASE WIRING SHALL BE LOCATED AND SECURED UNDER THE ARRAY USING SUITABLE WIRING CLIPS.WIRING SHALL NOT MAKE CONTACT WITH THE ROOF SURFACE AND SHALL BE MANAGED IN A WORKMAN-LIKE MANNER. 12)EQUIPMENT GROUNDING CONDUCTORS WILL BE SIZED IN ACCORDANCE WITH NEC TABLE 250.122. 13)CONDUCTOR TERMINATIONS WILL BE TORQUED PER DEVICE LISTING,OR MANUFACTURER'S RECOMMENDATIONS. 14)A PV AGGREGATION PANEL(SUB PANEL)WILL NOT BE INCLUDED FOR SYSTEMS WITH ONE BRANCH CIRCUIT. 15)A DEDICATED 120V BRANCH CIRCUIT IS REQUIRED IN MASTER CLOSET(OR EQUIVALENT)FOR ENPHASE ENVOY MONITOR. SIGNAGE- 16)PV SYSTEMS SHALL BE CLEARLY MARKED IN ACCORDANCE WITH NEC ARTICLE 690 AND OTHER APPLICABLE STATE AND LOCAL CODES. 17)ALL SAFETY MARKING /PLACARDS SHALL BE PERMANENTLY ATTACHED BY ADHESIVE OR OTHER MECHANICAL MEANS. 18)MARKING /PLACARDS WILL BE METAL OR.PLASTIC WITH ENGRAVED OR MACHINE PRINTED LETTERING. BACKGROUND WILL BE RED WITH WHITE CAPITAL LETTERING OF MINIMUM HEIGHT J. 19)ALL WIRING/RACEWAYS/JUNCTION BOXES WILL BE MARKED'PHOTOVOLTAIC POWER SOURCE,"OR EQUIVALENT;WIRING/RACEWAYS SHALL BE MARKED EVERY 10'. BUILDER ELECTRICAL AND SOLAR CONTRACTORS- 20)INSTALLATION SHALL BE COMPLETED IN A NEAT AND WORKMAN-LIKE MANNER. 21)SPACE REQUIREMENTS FOR ALL ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110.26. MERIDIAN AT LENNAR: ORIGINAL BY FREDDY BERNALRUI DATE 14.7.14 980 MONTECITO DRIVE REVIEWED BY:TOM FIDDES I DATE-14.7.14 MENIFEE HILLS CORONA,CA 92789 REV.# BY DATE DESCRIPTION Vnc3masb6 some DWG TITLE: PAGE#: I SCALE: SITE LOCATION: 4671&o,CO S Street INDIVIDUAL PLOT PLAN 4 NITS 29273 NECTARINE ST Bou18e/ 0304 NOTES MENIFEE,CA 92584 303.447.0300 CAUTION: POWER TO THIS BUILDING IS SUPPLIED BY THE UTILITY AND A SOLAR PV SYSTEM. DISCONNECTS ARE LOCATED AS SHOWN. SOLADECK WIRE TRANSITION 80X (UNDER ARRAY) UTILITY METER 8 MAIN SERVICE PANEL (VERIFIED BY BUILDER) PV AC DISCONNECT EXTERIOR-GARAGE SERVICE BY QUALIFIED PERSONNEL ONLY CONTACT: SUNSTREET ENERGY GROUP 1-877-SLR-POWR NOTE: SEE MASTER SET FOR ADDITIONAL PLACARD INFORMATION MERIDIAN AT LENNAR ORIGINAL BY: FREDDY BERNALRUI DATE:14.7.14 980 MONTECITO DRIVE REV.REVIEWED DATE DESCRIPTION DESCRIPTONTE:14.7.14 MENIFEE HILLS CORONA,CA 92789 namasGe DWG TITLE: PAGE#: SCALE: SITE LOCATION: INDIVIDUAL 45]i Street PLOT PLAN 5 NTS 29273 NECTARINE 5T Boulder 014 CO 3 80304 PLACARDS MENIFEE,CA 92584 03.44].000